28
Baldor Large Frame AC Induction Motors

Baldor Large Frame AC Induction Motorsucc.colorado.edu/baldor-reliance/BR435.pdf · 2 The best value in large motors, too. Years ago, when Baldor began making large frame AC motors

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Baldor Large Frame AC Induction Motorsucc.colorado.edu/baldor-reliance/BR435.pdf · 2 The best value in large motors, too. Years ago, when Baldor began making large frame AC motors

BaldorLarge Frame ACInduction Motors

Page 2: Baldor Large Frame AC Induction Motorsucc.colorado.edu/baldor-reliance/BR435.pdf · 2 The best value in large motors, too. Years ago, when Baldor began making large frame AC motors

www.baldor.com1

Why Baldor?For over 80 years,Baldor has strivedto providecustomers with thebest value andreliability inindustrial electricmotors. Thatdedication showsin customerpreference forBaldor motors. Tobe considered asthe mostpreferred...

Baldor offers the industry’s broadest line of stockproducts. Save valuable time with just one call to Baldor. We offer more than 7,000 stock motors, drivesand gearboxes.

Energy-efficiency leader. We began lowering the energy consumption of our motors in the 1920s, longbefore others were even talking about it. Today, ourexpansive line of Super-E® premium-efficient motorsranges from 1 through 1500 hp. Baldor’s Super-E® lineoffers customers the highest overall efficiency levels in the industry.

Baldor products are available at more locations thanany other brand.

Our 40 district offices across North America offerimmediate availability of Baldor products to thousandsof distributors.

Continuous innovation toimprove reliability.Baldor leads the motor

industry in applying new technologies and materials toimprove motor reliability. Baldor was the first to introduceISR® (Inverter Spike Resistant®) magnet wire, which is upto 100 times more resistant to voltage spikes. Baldorwas first to use Exxon’s new Polyrex® EM grease, whichprotects motor bearings better, providing improvedlubrication life, greater shear stability, and superiorresistance to washout, rust and corrosion.

Industry’sshortest leadtimes/Flexiblemanufacturing.Baldor has theindustry’sshortest leadtimes on custommotors – just tenworking days.Our unique FLEXFLOW™ manufacturing process lets us produce anyorder in any quantity, quickly and efficiently.

Industry’s best information. Only Baldor offerscustomers so many choices for product information witha wide variety of catalogs and product brochures, a CD-ROM electronic catalog, the Baldor Web site(www.baldor.com), or you may talk to a Baldor customerservice person at one of our sales offices.

1985

20%

1990 2000

50%

90%Customer Preference

Percentage of research studies in whichBaldor was chosen most preferred.

PageSpecifications and Features• Design Features 3• ISR® Wire / POLYREX®EM Grease 5• Energy Savings 6• Design Characteristics 7• Open Drip Proof - WPI, WPII 9• IEC Metric Frame 10• Totally Enclosed Fan Cooled 11• Inverter/Vector - Totally Enclosed Blower Cooled 13• Matched Performance™ Curve 14• Explosion-Proof 14

Custom Motor Options 18

Motor Performance Data• Totally Enclosed Fan Cooled 15• Totally Enclosed Blower Cooled 17• Open Drip Proof 17• Explosion Proof 17

Motor Dimensions 19-23

Connection Diagrams 24-25

Sample Test Data Report 26

Table of Contents

Page 3: Baldor Large Frame AC Induction Motorsucc.colorado.edu/baldor-reliance/BR435.pdf · 2 The best value in large motors, too. Years ago, when Baldor began making large frame AC motors

www.baldor.com 2

The best value in large motors, too.Years ago, when Baldor began making large frame ACmotors and drives, we spent a lot of time in the field.We talked in depth with plant maintenance and designengineers. We asked about tough environments suchas mining, pulp and paper manufacturing, andchemical processing. We took the opportunity to learnin great detail what capabilities and characteristicspeople like and need. And most important, we learnedwhat not to do.

One of the frequent suggestions was the need forbetter structural integrity and rigidity. And manywanted motors that were tough enough to withstandthe rigors of even the most extreme applications.

Today, Baldor makes tough, reliable motors up to1,500 HP for a wide variety of applications. And wecontinue to listen and follow through on whatcustomers want. That’s why you can count on Baldorfor superior value.

Baldor large frame motors and drives feature:

• Choice of all popular enclosures, voltages and frequency, custom orders are no problem.

• Choice of Baldor Super-E® NEMA Premium™ efficiency or high efficiency designs.

• Extra heavy-duty cast iron frames, endplates and stiff foot structures, to minimize potential vibration problems.

• Premium rotor system design, to operate below the 1st critical design speed by at least a 15% safety margin — can be operated from a adjustable speed control through entire speed range.

• Choice of standard high-pressure die-cast aluminum rotors or fabricated copper bar rotors.

• Precision dynamic balanced with state-of-the-art equipment, to ensure finished motors meet NEMA vibration standards.

• Class H-rated vacuum pressure impregnated (VPI) insulation systems with surge rings on all end turns to minimize risk of premature failure.

• Electrical grade steel laminations, to minimize eddy currents and hysteresis losses, results in cooler operation and more efficiency.

• Upgraded C-5 core plates, to reduce core losses for the life of the motor (others offer as low as C-3, standard).

• Ability to meet many industry standard specifications such as IEEE 841, API 541, API 547 or company-specific specs.

There are many other advantages to specifying Baldor large frame motors or drives. You’ll find them on the following pages — as well as all the specsyou need to make the perfect decision for your application.

Take a look. Talk to your Baldor distributor. If youdon’t see what you need, ask us about customcapabilities. You can likely have it on your floor inthree weeks or less.

A Baldor 400 Hp, 449T Open Drip Proof Motor located in the Dallas water pumping station.

Page 4: Baldor Large Frame AC Induction Motorsucc.colorado.edu/baldor-reliance/BR435.pdf · 2 The best value in large motors, too. Years ago, when Baldor began making large frame AC motors

www.baldor.com3

Large Frame AC Motors: Built for Reliable Performance

Dual mounting foot holes, especiallyconvenient when mounting a motorfor replacement duty.

Fan and fan cover designedfor maximum cooling andquieter operation.

Stator and rotors utilize C-5 coreproviding low core losses for thelife of the motor.

Regreasing provisions withreliefs for easy bearing maintenance.

Two-part epoxy primerinside and out; two-partepoxy finish paint on severe duty motors.

Rugged cast iron frames, endplatesand conduit boxes for greater strengthand stiffness, resulting in lowervibration and longer life. Diagonally split oversized cast iron conduit box

exceeding NEC standards makes connectionseasier. Rotatable in 90° increments and is easilyconverted from F-1 to F-2 mounting. Provisionfor grounding in conduit box and on the ODEmounting foot.

Standard surge ropes on endturns.

Class F (or better) insulation system allowswinding to withstand higher temperatures resultingin longer life. Medium voltage motors featureformed copper coils with glass mica-wrappedmagnet wire, further insulated with Nomex® tape.Baldor ISR (Inverter Spike Resistant®)coppermagnet wire on low voltage motors (<600V).

Standard vacuumpressure impregnation(VPI) using 100%epoxy solids for longlife and greaterprotection.

Page 5: Baldor Large Frame AC Induction Motorsucc.colorado.edu/baldor-reliance/BR435.pdf · 2 The best value in large motors, too. Years ago, when Baldor began making large frame AC motors

www.baldor.com 4

Locked bearing constructionreduces endplay. Convertible toroller bearing for belted loads.Optional sleeve bearings available.

Auxiliary conduit box on mediumvoltage ratings for windingRTD’s and space heaters.

High-pressure die cast aluminumrotor through 449T frame; fabricatedcopper bar rotor on larger sizes forincreased efficiency. Precisionbalanced for smooth operation andlonger bearing life.

Operates below the first critical speed by at least a15% margin - allows operation throughout entire speedrange with adjustable speed control.

High strength shaft steel.

Enclosure 449T 5000 5800 Ref. Page

TEFC 250-400 HP 400-600 HP 400-900 HP 6

ODP 200-450 HP 500-800 HP 500-1500 HP 8

WPI 500-800 HP 500-1500 HP 8

WPII 500-800 HP 500-1500 HP 8

Inverter/Vector

250-350 HP 400-600 HP 400-800 HP 10

Explosion Proof

250-350 HP 11

Typical 4-Pole HP ranges.

Generalized RangesFRAME SIZES

Page 6: Baldor Large Frame AC Induction Motorsucc.colorado.edu/baldor-reliance/BR435.pdf · 2 The best value in large motors, too. Years ago, when Baldor began making large frame AC motors

www.baldor.com5

Baldor’s Severe Duty motors are another example of our commitment to provide reliableperformance, while exceeding customer expectations.

Recognized as “Product of the Year”by Plant Engineering magazine in1996, Baldor’s ISR wire is a standardfeature in Baldor AC motors, 575 voltand under, 1 hp and up.

Motors wound with ISR wire are up to100 times more resistant to transientvoltage spikes, high frequencies andshort rise time pulse frequentlyproduced by inverters and vectordrives. The result is a better motor withlonger life, reduced downtime andbetter overall value.

It’s a fact: Bearing failure is the #1 mechanical reason for motor failure. So the better the greaseprotecting those bearings, the better and longer the motor performs.

Today, that better grease is Exxon’s new Polyrex® EM polyurea grease – now standard on allBaldor motors. It provides lubrication life of more than four times greater than other polyureagreases in tests up to 350°F. It exhibits greater durability when subjected to mechanical shearingforces. Furthermore, a specially formulated additive in the grease resists washout, rust andcorrosion even when subjected to salt water conditions.

800

700

600

500

400

300

200

100

0

AS

TM

D 3

336 G

rease

Lif

e a

t350˚F

(hours

)

Polyrex® EM CompetitivePolyurea Grease

Typical Synthetic

Lithium ComplexGrease

TypicalLithium ComplexGrease

In the severe ASTM D 3336 High-Temperature Grease Life Test,Polyrex EM dramatically out performed a competitive polyurea

grease and conventional lithium-complex greases.

Source: Exxon Mobil Product Data Sheet DG-3C, 6/15/99.

AS

ST

M D

217

Cone P

enetr

ati

on (m

m/1

0)

265280295310325340355370385400415430

Polyrex® EM CompetitivePolyurea Grease

Typical Lithium Complex Grease

As illustrated here, the proprietary polyurea thickener system inPolyrex EM exhibits excellent durability and stability when subjected to

a mechanical shearing force. Mechanical shear stability is a measurement of the greases thickener system. Good mechanical shear stability is

important in roller bearing applications where excessive grease softening may lead to grease leakage or purging from the bearing.

Source: Exxon Mobil Product Data Sheet DG-3C, 6/15/99.

Penetration after60 strokes

Penetration after100,000 strokes

Excellent Shear StabilityOutstanding High-Temperature

Lubrication Life

Going Beyond the Industry Standardin Severe Duty Motors

1000

100

10

1

0.1

Ind

ex

Moisture ResistantMR Wire

“Triple Build”Wire

ISR® Wir e

Technical Specifications:NEMA MW-35

Pulse EnduranceTest Conditions: Twisted pairs @ 20,000 Hz, 2 kV, 0.025 microsecond risetime, 50% duty cycle, 90°C

Pulse Endurance Index = Life of Product/Life of 18 H MW-35 (Reference)

Thermal Properties, Chemical Resistance and Dielectric Strength:ISR® Wire is equal to or better than MR wire.

Thermal Rating: 200°C

Source: Phelps Dodge Magnet Wire Company (Used with permission)

Wound with ISR® (Inverter Spike Resistant®) Magnet Wire

ISR® Wire is Superior in Pulse Endurance Test

Standard on All Baldor Motors: Exxon Polyrex® EM Polyurea Grease

Page 7: Baldor Large Frame AC Induction Motorsucc.colorado.edu/baldor-reliance/BR435.pdf · 2 The best value in large motors, too. Years ago, when Baldor began making large frame AC motors

www.baldor.com 6

Making Energy Efficiency Work For YouWhy is Energy Efficiency Important?Electric motor-driven systems used in industrial processes consumed 679 billion kWh, or 63% of all electricity used inU.S. industrial sector, according to a U.S. Department of Energy report published in 1998. The report goes on to revealthat industrial motor energy could be reduced by up to 18 percent if companies were to apply motor and motor systemefficiency upgrades, including the use of adjustable speed drives. The potential positive impacts on companies’ bottomlines and the environment are significant.

Purchase Price is Only a Small Piece of the PieThe pie chart to the right shows the typical lifecycle cost of a 100 hp motor operating incontinuous duty over a 20-year life. As you cansee, the original purchase price is almostinsignificant compared to what it will cost to powerthe motor during its useful life.

How Baldor Super-E®

Efficiencies Compare toIndustry StandardsBaldor’s line of Super-E motors offers customersthe highest level of overall efficiencies availablefrom any motor manufacturer, complying withNEMA Premium™ efficiency.

BE$T Baldor Energy SavingsTool™ Software Makes Calculating Payback EasyIn order to make payback calculations easier forcustomers, Baldor developed BE$T (Baldor EnergySavings Tool). BE$T helps calculate energy costand energy savings for motors, as well aspayback timeframes. A popular feature of BE$T isthat it allows users to make head-to-headcomparisons of up to three motors, givingcustomers the information to make an informeddecision through comparative analysis.

BE$T Baldor Energy Savings Tool is available as adownload through Baldor’s award-winning Website (www.baldor.com/support/index.asp,) as well as a stand-alone CD-Rom available from the Baldor Literature Hotline (1-800-828-4920).

Power Cost Per kWH

168 Hour WeekContinuous

80 Hour Week2 Shifts

40 Hour Week1 Shift

Dolla

r S

avi

ngs

Per

Year

Savings based on a 40 hp, Baldor Super-E – 94.5% compared with the average efficiency of motors in use.(50 weeks/year)

.05 .06 .07 .08 .09 .100

300

600

900

1200

$1500

1 1.5 2 3 5 8 10 15 20 25 30 40 50 60 75 100 125 200

Horsepower

BaldorSuper-E®

EPActefficiencies

Average efficiency of motors in use

70

85

100%

InitialPurchase 2%

OneRewind 0.7%

Energy97.3%

Electric Motor Efficiency Ratings

What is Higher Efficiency Worth?

Page 8: Baldor Large Frame AC Induction Motorsucc.colorado.edu/baldor-reliance/BR435.pdf · 2 The best value in large motors, too. Years ago, when Baldor began making large frame AC motors

Low MediumSpecification Description Voltage VoltageVoltage 460 or 575 volts, random-wound S

950 volts, random-wound O2300, 3300, 4160 or 2300/4160 volts, formed-coil S460, 950 or 6600 volts, formed-coil O

Frequency 60 Hz standard, 50 Hz optional S SService Factor 1.15 standard S SRatings NEMA Design B S S

NEMA Design C (contact Baldor for frame size) O ONEMA Design D (contact Baldor for frame size), 1.0 S.F. O OCrusher Duty (high pull-out, pull-up and locked rotor torques) O O

Duty Cycle Continuous Duty S SSpecial Duty Cycles O O

Ambient Temperature 40o C ambient temperature S SHigher or lower ambient temperatures O O

Temperature Rise Class B rise (80o C) at 1.0 service factor, Class F rise at 1.15SF S SLaminations Low-loss electrical grade steel, C-5 core plate S SWindings Class H+ (200o C) ISR (Inverter Spike Resistant)® copper magnet wire S

Class H+ (200o C) Copper form-wound coils wound with mica tape and VPI epoxy impregnated S

Insulation Class Class F, Non-hygroscopic epoxy VPI S SClass H, Non-hygroscopic epoxy VPI O O

End Turn Bracing Surge rings laced to end-turns and VPI epoxy impregnated for structural integrity S S

Stator Insulation Nomex® Class H slot liner S SWoven Class H glass phase insulation SEpoxy impregnated blocking felt between coils S

Lead Material Non-wicking cross-linked polyethylene material S SThermal Protection Thermostats S O

RTDs with separate conduit box 100Ω platinum standard, 10Ω copper or 120Ω nickel optional; (RTDs standard in stock TEFC and ODP motors 300 Hp and up) O OThermistors O O

Space Heaters 120 volt standard, other voltages optional(Strip space heaters standard in stock TEFC motors 300 Hp and up) O O

Feedback Devices 1024 PPR Electrically isolated BEI optical encoder standard on Baldor Vector Drive® motors (other PPR available) O ONorthStar® (LakeShore) or Avtron® pulse generators available O OResolvers available O O

Testing Standard test supplied with motor (Balance test, winding resistance, no-load, full load, amps and speed, power factor, torque and hi-pot test per NEMA MG-1) S SHeat run and complete efficiency testing at temperature O OEither of above tests as witnessed O O

Approvals CSA recognized components through 449T (File LR2262) 5000 and 5800 TEFC frame through 600 HP and up to 600 volts; 500 HP and up to 4160 volts (File LR36841) S S

www.baldor.com7

Electrical Design Characteristics

S = Standard O = Optional

Page 9: Baldor Large Frame AC Induction Motorsucc.colorado.edu/baldor-reliance/BR435.pdf · 2 The best value in large motors, too. Years ago, when Baldor began making large frame AC motors

www.baldor.com 8

Low MediumSpecification Description Voltage VoltageFrame Dimensions NEMA S S

IEC Metric O OConstruction Complete cast iron frame, endplates, conduit box and fan cover

(5800 frame has steel fan cover) S SMultiple Mounting Multiple mounting holes standard. S SHoles in Base Dowel pin holes standard on all 5000 and 5800 frames.Face mounting C-face, D-flange, P-base available O O

Custom mounting configurations available O ONameplate Stainless steel, Complete operating data in accordance

with NEMA MG-1. Bearing identification numbers included S SConduit Box Oversized cast iron, diagonally split box, rotatable in 90o increments.

Gasketed lid and gaskets between frame and box. NPT threaded opening. F-1 orientation standard, convertible to F-2 (top-mount conversion available on 5800 frame) S SExtra-large oversized conduit boxes available O O

Slinger & Seals Forsheda® V-type neoprene slinger each (Chemical Process motors only) S SInpro seal® on shaft O O

Drains One-way drain and breather located at lowest point of motor when mounted in a horizontal position O O

Hardware Grade 5, U.S. Standard, zinc dichromate or cadmium-plated steel S SStainless steel hardware O O

Ground Lug Located in conduit box. Silicon-bronze stud-type. S SLifting Provisions Integrally-cast lifting lugs – motor can be lifted with any enclosure in tact S SEnclosure TEFC, Open Drip-proof, WPI, WPII, TEBC, TEWAACCooling Fan TEFC & TEBC — Non-sparking, glass-filled polypropylene S S

Non-sparking metal O ORotor Construction High pressure die-cast aluminum (through 449) S S

Fabricated copper bar construction (5000 up) S SBalance Dynamically balanced better than NEMA MG1 specs S SShaft Material 1045 high strength steel (through 5000 frame) S S

4140 high strength steel (5800 frame - up) S SOther high strength alloys or forged shafts O O

Paint Grey lacquer over primer coat S STwo-part epoxy system with 4-6 mils build (Chemical Process motors) S SCustomer specified paint O O

Bearings Premium grade vacuum-degassed ball bearings S SRoller bearing on drive end O ORenk sleeve bearings (5000-up) O OElectrically isolated bearings O OBearing temperature RTDs O OVibration monitors O O

Lubrication Chevron® SRI grease (or equivalent) S SOil lube for sleeve bearings S SCustomer specified grease O OOil mist lubrication O O

Grease Provisions NPT fittings installed in endplate with pressure relief fittings on drain lines S SOil sight gauges for sleeve bearings S S

Engineering Specifications API 541, API 547 O OIEEE 841- 2001 O OCustomer specific requirements O O

Limited Warranty 3 years on Super-E®, 24 months on Standard-E™,18 months most other motors S S

S = Standard O = Optional

Mechanical Design Characteristics

Page 10: Baldor Large Frame AC Induction Motorsucc.colorado.edu/baldor-reliance/BR435.pdf · 2 The best value in large motors, too. Years ago, when Baldor began making large frame AC motors

www.baldor.com9

Open Drip Proof and WPI — WPIIBaldor Electric offers a rugged cast iron industrial motor in yourchoice of open enclosures. Standard motor designs are high efficiency, but our Super-E® with NEMA Premium™efficiency is also available.

• 460, 575, 950, 2300, 3300, 4160 or 6600 volts — 60 Hz

• 380, 400, 415, 950, 2300, 4160 or 6000 volts — 50 Hz

• High efficiency or Super-E® NEMA Premium™ efficiency

• Class B rise with Class F insulation

• Baldor ISR (Inverter Spike Resistant)® magnet wire on designsbelow 600 volts

RPMHP kW 3600 1800 1200 900150 112 449TS 449T 449T 5009L200 150 449TS 449T 5009L 5009L250 187 449TS 449T 5009L 5009L300 224 449TS 449T/5009L 5009L 5011L350 261 449TS*/5009S 5009L 5009L 5011L400 298 5009S 5009L 5011L 5011L*/5808450 336 5009S 5009L 5011L 5808500 373 5009S 5009L 5011L 5810600 448 5009S 5011L 5808 5810700 522 5009S 5011L 5810 5812800 600 5009S*/5808S 5808 5810*/5812 5812*900 671 5808S 5810 5812* —1000 746 5808S* 5810 — —1250 933 — 5810 — —1500 1120 — 5812 — —

ODP WPI High Efficiency 2300 or 4160 volts, 60 Hz, 1.15 SF

RPMHP kW 3600 1800 1200 900200 150 444TS 445T 445T 5007L250 187 445TS 445T 449T 5009L300 224 445TS 445T 449T 5009L350 261 445TS 445T 5009L 5009L400 298 449TS 449T 5009L 5011L450 336 449TS/5009S 449T 5009L 5011L500 373 5009S 5009L 5011L 5808600 448 5009S 5009L 5011L 5810700 522 5009S 5011L 5808 5810800 600 5009S*/5808S 5011L 5810 5812*900 671 5808S 5808 5810*/5812 —1000 746 5808S 5810 5812* —1250 933 — 5810 — —1500 1120 — 5810*/5812 — —

ODP High Efficiency 460 or 575 volts, 60 Hz, 1.15 SF

444TS, 445TS, 445T motors do not have standard VPI. 5000 & 5800 frame motors can be ODP or WPI.

*1.0 SF, Class F Rise.Data subject to change without notice.

5000 & 5800 frame motors can be ODP or WPI.Contact a Baldor office for latest capabilities.

Page 11: Baldor Large Frame AC Induction Motorsucc.colorado.edu/baldor-reliance/BR435.pdf · 2 The best value in large motors, too. Years ago, when Baldor began making large frame AC motors

WPII High Efficiency 460 or 575 volts, 60 Hz, 1.15 SF

WPII High Efficiency 2300 or 4160 volts, 60 Hz, 1.15 SF

ODP/WPI High Efficiency 6600 volts, 60 Hz, 1.15 SF

IEC Metric Frames AvailableIn addition to the NEMA frames show here, Baldor motorsare available with IEC metric mounting dimensions inframes through 450. Contact Baldor for dimensions andlayout drawings.

RPMHP kW 3600 1800 1200 900300 224 5009S 5009L 5009L 5009L350 261 5009S 5009L 5009L 5009L400 298 5009S 5009L 5009L 5011L450 336 5009S 5009L 5011L 5011L/5808500 373 5009S 5009L 5011L 5808600 448 5009S 5011L 5011L 5810700 522 5009S*/5808S 5011L 5808 5810800 600 5808S 5011L 5810 —900 671 5808S 5810 5810*/5812 —1000 746 5808S* 5810 5812* —1250 933 — 5810 — —1500 1120 — 5810*/5812 — —

RPMHP kW 3600 1800 1200 900350 261 5808S 5009L 5009L 5011L400 298 5808S 5009L 5009L 5808450 336 5808S 5009L 5011L 5810500 373 5808S 5009L 5011L*/5808 5810600 448 5808S 5011L 5810 —700 522 5808S 5011L*/5808 — —

RPMHP kW 3600 1800 1200 900300 224 5009S 5009L 5009L 5009L350 261 5009S 5009L 5009L 5009L400 298 5009S 5009L 5011L 5011L*/5808450 336 5009S 5009L 5011L 5808500 373 5009S 5009L 5011L 5810600 448 5009S 5011L 5808 5812700 522 5009S/5808S 5011L 5810 5812*800 600 5009S*/5808S 5808 5810 —900 671 5808S 5810 5810*/5812 —1000 746 5808S* 5810 — —1250 933 — 5810 — —1500 1120 — 5812 — —

*1.0 SF, Class F RiseData subject to change without notice.

Contact a Baldor office for latest capabilities.

www.baldor.com 10

Page 12: Baldor Large Frame AC Induction Motorsucc.colorado.edu/baldor-reliance/BR435.pdf · 2 The best value in large motors, too. Years ago, when Baldor began making large frame AC motors

www.baldor.com11

TEFC — Totally Enclosed Fan CooledBaldor Electric offers the ultimate rugged cast iron industrial motor for your most severe process applications. Motor designs are Super-E® premium efficiency, but high efficiency is also available.

• 460, 575, 950, 2300, 3300, 4160 or 6600 volts — 60 Hz

• 380, 400, 415, 950, 2300, 4160 or 6000 volts — 50 Hz

• Super-E® premium or high efficiency

• Class B rise with Class F insulation

• Baldor ISR (Inverter Spike Resistant)®

magnet wire on designs below 600 volts

TEFC Super-E® NEMA Premium™ Efficiency 460 or 575 Volts, 60 Hz, 1.15 SF

*1.0 SF, Class F RiseSleeve bearings required.Data subject to change without notice.

Contact a Baldor office for latest capabilities.

RPMHP kW 3600 1800 1200 900200 150 447TS 447T 449T 5007L250 187 449TS 449T 449TY 5009L/5810300 224 449TS 449TY/449TSY 449TY 5011LY/5810350 261 449TS 449TY/449TSY 5009L/5810 5011LY/5810400 298 449TS 449TY/449TSY 5011LY/5810 5810

5007L/5810450 336 5007SY 5007L/5810 5011LY/5810 5810*500 373 5009SY 5009L/5810 5011LY/5810 5812600 448 5009SY 5011LY/5810 5810 5812700 522 5009SY* 5810 5810*/5812 —800 600 — 5810*/5812 — —900 671 — 5812* — —

Page 13: Baldor Large Frame AC Induction Motorsucc.colorado.edu/baldor-reliance/BR435.pdf · 2 The best value in large motors, too. Years ago, when Baldor began making large frame AC motors

www.baldor.com 12

TEFC Super-E® NEMA Premium™ Efficiency 2300 or 4160 Volts, 60 Hz, 1.15 SF

TEFC Super-E® NEMA Premium™ Efficiency 6600 Volts, 60 Hz, 1.15 SF

*1.0 SF, Class F RiseSleeve bearings required.Data subject to change without notice.

Contact a Baldor office for latest capabilities.

RPMHP kW 3600 1800 1200 900100 74.6 — — — 449T125 93.2 — — — 449T150 112 447TS 449T 449T 5007L200 150 449TS 449T 449T/5007L 5009L250 187 449TS/5007SY 449T/5007L 5007L/5009L 5011LY/5810300 224 449TS*/5007SY 449TY/5007L/5011LY 5009L/5011LY/5810 5011LY/5810350 261 5007SY 5007L/5011LY 5009L/5011LY/5810 5810400 298 5007SY 5007L/5011LY/5810 5011LY/5810 5810450 336 5007SY 5007L/5011LY/5810 5011LY/5810 5810500 373 5009SY 5009L/5011LY/5810 5011LY/5810 5810*/5812600 448 5009SY* 5011LY/5810 5810 5812*700 522 — 5810 5810*/5812 —800 600 — 5810*/5812 — —900 671 — 5812*

RPMHP kW 3600 1800 1200 900150 112 5007SY 5007L 5007L 5009L200 150 5007SY 5007L 5007L 5011LY250 187 5007SY 5007L 5009L 5011LY300 224 5009SY 5007L 5011LY 5810350 261 5009SY 5007L 5011LY 5810400 298 5009SY 5009L 5011LY 5810450 336 5009SY 5011LY 5810 5810*500 373 5009SY* 5011LY 5810 —600 448 — 5810 5810* —

Page 14: Baldor Large Frame AC Induction Motorsucc.colorado.edu/baldor-reliance/BR435.pdf · 2 The best value in large motors, too. Years ago, when Baldor began making large frame AC motors

www.baldor.com13

Inverter / Vector Duty - TEBC — Totally Enclosed Blower CooledBaldor Electric offers the ultimate rugged cast iron industrial motor for your adjustable speed, constant torque applications. Motors are Super-E®

NEMA Premium™ efficiency.

• 460 or 575 or 6600 volts — 60 Hz

• 380, 400 or 415, or 6000 volts — 50 Hz

• Super-E® NEMA Premium™ efficiency

• Able to start across line without drive

• Class F rise with Class H insulation

• Baldor ISR (Inverter Spike Resistant)®

magnet wire on designs below 600 volts

• Separately powered heavy duty axial cooling fan

• Electrically isolated BEI optical encoder on vector drive motors – optional Avtron orNorthStar pulse generators

• Shaft grounding assembly

• Option formed coil winding on 460 or 575 V.

Inverter/Vector 460 or 575 Volts, 60 Hz, 1.0 SF

*1.0 SF, Class F RiseSleeve bearings required.Data subject to change without notice.

Contact a Baldor office for latest capabilities.

RPMHP kW 3600 1800 1200 900200 150 447TS 447T 449T 5007L250 187 449TS 449T 449T 5009L/5810300 224 449TS 449T 449T 5011LY/5810350 261 449TS 449T 5009L/5810 5011LY/5810400 298 449TS 5007L/5810 5011LY/5810 5810450 336 5007S 5007L/5810 5011LY/5810 5810500 373 5009S 5009L/5810 5011LY/5810 5810600 448 5009S 5011LY/5810 5810 —700 522 — 5810 5810 —800 600 — 5810 — —

Page 15: Baldor Large Frame AC Induction Motorsucc.colorado.edu/baldor-reliance/BR435.pdf · 2 The best value in large motors, too. Years ago, when Baldor began making large frame AC motors

www.baldor.com 14

Matched Performance™ CurvesMatched Performance™ is Baldor’s solution to the concern, “What kind of constanthorsepower speed range will I get with thiscombination of motor and control?” Each test is performed in Baldor's own engineering laboratory.

These performance curves show the continuous operating constant torque speedrange that can be produced without exceedingClass F temperature rise in the motor. Peaktorque is the maximum amount of torque aBaldor inverter or vector drive can produce. This may be limited by either the motor’sbreakdown torque or the current from the control.

0 300 600 900 1200 1500 1800 21000.0

150.0

300.0

450.0

600.0

750.0

900.0

1050.0

1200.0

0.00

50.00

100.00

150.00

200.00

250.00

300.00

350.00

400.00

450.00

TORQUE

AMPS

TO

RQ

UE

(ft-

lbs)

SPEED (rpm)

HO

RS

EP

OW

ER

• A

MP

S

1350.0PEAK TORQUE

HORSEPOWER

CONTINUOUSOPERATING AREA

Explosion Proof MotorsBaldor Electric offers the ultimate rugged cast iron industrial motor for applications where hazardous fumes or dust may be present.

• 460, or 575 — 60 Hz

• 380, 400, or 415 volts — 50 Hz

• Super-E® NEMA Premium™ efficiency or high efficiency

• Class B rise with Class F insulation

• Baldor ISR (Inverter Spike Resistant)® magnet wire

• UL and CSA approved for hazardous locations

• Includes UL approved conduit box

Explosion Proof Motors 460 or 575 volts, 60 Hz, 1.0 SF

Matched Performance Curve for Baldor 200 HP TEBC motor and control.

Class I, Group C & D; Class II, Groups F and G, T3CData subject to change without notice.

Contact a Baldor office for latest capabilities.

RPMHP kW 3600 1800 1200 900150 112 445TS 445T 449T 449T200 150 449TS 449T 449T —250 187 449TS 449T 449T —300 224 449TS 449T — —350 261 449TS 449TY — —

Page 16: Baldor Large Frame AC Induction Motorsucc.colorado.edu/baldor-reliance/BR435.pdf · 2 The best value in large motors, too. Years ago, when Baldor began making large frame AC motors

AMPS @ 460V RATED EFFICIENCY % POWER FACTOR % BEARINGSFULL LOCKED TORQUE FULL FULL

HP kW RPM FRAME CATALOG # LOAD ROTOR LB. FT. 1/2 3/4 LOAD 1/2 3/4 LOAD D.E. O.D.E.200 149 1180 449T M44206T-4 236 1337 885 94.8 95.3 95.0 64 76 81 6314 6319300 224 1785 449T M44304T-4 328 2566 883 95.8 96.0 95.8 81 86 88 6314 6319350 261 1785 449T M44354T-4 388 2871 1032 94.5 95.7 95.8 81 88 89 6314 6319400 298 1785 449T M44404T-4 440 3134 1180 95.8 96.1 95.8 82 88 89 6314 6319

www.baldor.com15

TEFC NEMA Premium™ Efficiency 460 Volts, 60 Hz, 1.15 SF with Roller BearingsAMPS @ 460V RATED EFFICIENCY % POWER FACTOR % BEARINGSFULL LOCKED TORQUE FULL FULL

HP kW RPM FRAME CATALOG # LOAD ROTOR LB. FT. 1/2 3/4 LOAD 1/2 3/4 LOAD D.E. O.D.E.150 112 1180 447TY ECP44156TR-4 178 1154 667 95.2 95.8 95.8 49 79 82 NU319 6314200 149 1780 447TY ECP4407TR-4 225 1530 589 95.0 96.0 96.2 82 86 87 NU319 6314200 149 1180 449TY ECP44206TR-4 242 1647 890 94.5 95.2 95.8 70 80 81 NU319 6314250 187 1780 449TY ECP4408TR-4 281 1910 740 95.0 96.0 96.2 81 86 87 NU319 6314250 187 1180 449TY ECP44256TR-4 294 1690 1105 95.0 95.6 95.8 73 80 83 NU319 6314300 224 1785 449TY ECP44304TR-4 337 2290 883 95.2 96.0 96.2 81 86 87 NU319 6314300 224 1185 449TY ECP44306TR-4 355 2370 1328 94.3 95.0 95.0 71 80 83 NU319 6314300 1185 5007L Custom 344 2592 95.2 95.6 95.8 80 84 86350 261 1785 449TY ECP44354TR-4 393 2670 1032 95.0 95.8 96.2 81 86 87 NU319 6314400 298 1780 449TY ECP44404TR-4 449 3050 1179 95.2 96.0 96.2 81 86 87 NU319 6314

Performance Data

AMPS @ 460V RATED EFFICIENCY % POWER FACTOR % BEARINGSFULL LOCKED TORQUE FULL FULL

HP kW RPM FRAME CATALOG # LOAD ROTOR LB. FT. 1/2 3/4 LOAD 1/2 3/4 LOAD D.E. O.D.E.200 149 3570 447TS ECP4416T-4 214 1720 294 94.4 95.2 95.4 87 91 92 6314 6314200 149 1780 447TS ECP4407T-4 225 1530 589 95.0 96.0 96.2 82 86 87 6319 6314200 149 1180 449T ECP44206T-4 242 1647 890 94.5 95.2 95.8 70 80 81 6319 6314200 149 890 5007L Custom 238 1342 1180 93.7 94.4 95.0 76 81 82 6324 6222250 187 3545 449TS ECP44252T-4 272 2162 370 95.4 95.8 95.8 81 87 90 6314 6314250 187 1780 449T ECP4408T-4 281 1910 740 95.2 95.8 96.2 82 85 87 6319 6314250 187 1180 449TY ECP44256T-4 294 1690 1105 95.0 95.6 95.8 73 80 83 6319 6314250 187 890 5009L Custom 298 1775 1475 94.6 95.2 95.4 72 79 82 6324 6222300 224 3545 449TS ECP44302T-4 320 2546 444 95.3 95.5 95.8 86 90 91 6314 6314300 224 1785 449TY ECP44304T-4 337 2290 883 95.2 96.0 96.2 81 86 87 6319 6314300 224 1185 449TY ECP44306T-4 355 2370 1328 94.3 95.0 95.0 71 80 83 6319 6314300 224 1185 5007L Custom 344 2592 1765 95.2 95.6 95.8 80 84 86 6322 6222350 261 3545 449TS ECP44352T-4 344 2930 518 95.2 95.6 95.8 84 88 90 6314 6314350 261 1785 449TY ECP44354T-4 393 2670 1032 95.0 95.8 95.8 81 86 87 6319 6314350 261 1185 5009L Custom 400 1880 1551 95.5 95.8 95.8 79 82 84 6322 6222350 261 895 5810 Custom 422 2574 2054 94.0 94.5 94.5 68 77 81 — —400 298 3545 449TS ECP44402T-4 422 3155 592 95.4 95.8 95.8 89 92 93 6314 6314400 298 1780 449TY ECP44404T-4 454 3151 1179 95.6 95.8 96.2 78 82 87 6319 6314400 298 1190 5011L Custom 446 3025 1765 95.9 96.3 96.0 82 87 88 6322 6222400 298 890 5810 Custom — — 2358 — — — — — — — —450 336 3570 5009S Custom 482 2917 660 95.8 96.2 96.2 86 90 91 6314 6314450 336 1790 50011LY Custom 498 3315 1320 95.4 95.8 96.2 80 84 88 6322 6222450 336 1185 5011L Custom 486 3757 1995 94.9 95.7 95.8 78 86 87 6322 6222450 336 890 5810 Custom — — 2654 — — — — — — — —500 373 3575 5009S Custom 530 3389 735 96.2 96.4 96.2 89 92 92 6314 6314500 373 1785 5011L Custom 540 3487 1465 95.6 96.1 96.5 84 88 90 6322 6222500 373 1185 5011L Custom 552 3822 2216 96.0 96.2 96.2 82 87 89 6322 6222500 373 890 5810* Custom — — 2950 — — — — — — 6324 6322600 448 3575 5009S Custom 636 4464 881 95.8 96.0 96.2 89 91 92 6314 6314600 448 1790 5011L Custom 638 3803 1758 96.2 96.8 97.0 88 91 91 6322 6222600 448 1185 5810 Custom — — 2658 — — — — — — 6324 6322700 522 3585 5009S Custom — — 1025 — — — — — — 6314 6314700 522 1785 5810 Custom — — 2058 — — — — — — 6322 6322700 522 1185 5810* Custom — — 3101 — — — — — — 6324 6322800 600 1785 5810* Custom — — 2353 — — — — — — 6324 6322

*1.0 SF

TEFC NEMA Premium™ Efficiency 460 Volts, 3 Phase, 60 Hz, 1.15 SF

TEFC High Efficiency 460 Volts, 3 Phase, 60 Hz, 1.15 SF

If data is not shown, contact a Baldor office. Data subject to change without notice.

Contact a Baldor office for latest capabilities.

Page 17: Baldor Large Frame AC Induction Motorsucc.colorado.edu/baldor-reliance/BR435.pdf · 2 The best value in large motors, too. Years ago, when Baldor began making large frame AC motors

www.baldor.com 16

AMPS @ 575V RATED EFFICIENCY % POWER FACTOR % BEARINGSFULL LOCKED TORQUE FULL FULL

HP kW RPM FRAME CATALOG # LOAD ROTOR LB. FT. 1/2 3/4 LOAD 1/2 3/4 LOAD D.E. O.D.E.200 149 3570 447TS — 174 — 294 94.8 95.4 95.8 83 87 89 6314 6314200 149 1780 447T ECP4407T-5 179 1602 589 95.2 95.8 96.2 80 84 87 6319 6314200 149 1180 449T Custom 194 1341 890 94.4 95.1 95.8 75 78 81 6319 6314200 149 890 5007L Custom 196 1175 1180 94.6 95.2 95.0 70 78 81 6324 6222250 187 3545 449TS Custom — — 370 — — — — — — 6314 6314250 187 1780 449T Custom 249 1986 740 95.0 95.6 96.2 81 83 86 6319 6314250 187 1180 449TY Custom 235 — 1105 — — 95.8 — — 83 6319 6314250 187 890 5009L Custom 242 1390 1475 94.1 94.8 95.4 79 81 82 6324 6222300 224 3545 449TS Custom — — 444 — — — — — — 6314 6314300 224 1785 449TY Custom 319 2366 833 95.0 95.8 96.2 80 84 87 6319 6314300 224 1185 449TY Custom — — 1328 — — — — — — 6319 6314300 224 890 5011L Custom 290 1716 1765 94.8 95.2 95.4 77 80 82 6322 6222350 261 3545 449TS Custom — — 518 — — — — — — 6314 6314350 261 1785 449TY Custom 389 2773 1032 95.2 95.9 96.2 82 83 86 6319 6314350 261 1185 5009L Custom 308 2204 1551 95.1 95.5 95.8 83 87 88 6322 6222350 261 895 5810 Custom — — 2054 — — — — — — — —400 298 3545 449TS Custom — — 592 — — — — — — 6314 6314400 298 1780 449TY Custom 460 3162 1179 95.0 95.8 96.2 81 84 86 6319 6314400 298 1190 5011L Custom — — 1765 — — — — — — 6322 6222400 298 890 5810 Custom — — 2358 — — — — — — 6324 6322450 336 3570 5009S Custom — — 660 — — — — — — 6314 6314450 336 1790 5009L Custom — — 1320 — — — — — — 6322 6222450 336 1185 5011L Custom — — 1995 — — — — — — 6322 6222450 336 890 5810 Custom — — 2654 — — — — — — 6324 6322500 373 3575 5009S Custom 422 2622 735 95.5 96.0 96.2 88 91 92 6314 6314500 373 1785 5011L Custom — — 1465 — — — — — — 6322 6222500 373 1185 5011L Custom 438 3026 2216 96.2 96.4 96.2 82 87.5 89 6322 6222500 373 890 5810* Custom — — 2930 — — — — — — 6324 6322600 448 3575 5009S Custom — — 881 — — — — — — 6314 6314600 448 1790 5011L Custom 510 3760 1758 96.0 96.2 96.2 91.5 92.7 93.1 6322 6222600 448 1185 5810 Custom 532 3380 2641 95.8 96.1 96.2 80 83 87 6324 6322700 522 3585 5009S Custom — — 1025 — — — — — — 6314 6314700 522 1785 5810 Custom — — 2058 — — — — — — 6322 6322700 522 1185 5810* Custom — — 3101 — — — — — — 6324 6322800 600 1785 5810* Custom — — 2353 — — — — — — 6324 6322

TEFC NEMA Premium™ Efficiency 575 Volts, 60 Hz, 1.15 SF

AMPS @ 4160V RATED EFFICIENCY % POWER FACTOR % BEARINGSFULL LOCKED TORQUE FULL FULL

HP kW RPM FRAME CATALOG # LOAD ROTOR LB. FT. 1/2 3/4 LOAD 1/2 3/4 LOAD D.E. O.D.E.200 149 3570 447TS Custom 25 159 294 93.1 94.1 94.1 82 89 92 6314 6314200 149 1780 5007L Custom 25 152 589 94.0 94.5 94.1 85 89 89 6319 6314200 149 1185 5009L Custom 27 174 890 94.4 94.8 94.5 81 85 85 6319 6314200 149 890 50011L Custom 29 150 1180 93.5 93.9 93.6 73 77 77 6322 6222250 187 3570 5007SY ECP50252S-2341 31 216 367 94.4 95.1 95.0 86 90 91 6314 6314250 187 1790 5007L ECP50254L-2341 31 214 734 92.7 94.5 95.0 81 87 89 6322 6222250 187 1185 5009L ECP50256L-2341 30 380 1104 93.8 94.6 95.0 78 83 85 6324 6222250 187 890 5011LY Custom 36 194 1475 92.9 93.8 94.1 69 74 77 6322 6222300 224 3570 5007SY ECP50302S-2341 36 260 440 94.7 95.3 95.4 88 91 92 6314 6314300 224 1790 5009L ECP50304L-2341 37 239 880 93.4 94.9 95.4 83 88 90 6322 6222300 224 1185 5011LY ECP50306L-2341 40 505 1104 93.9 94.5 95.0 78 82 86 6324 6222300 224 890 5011LY Custom 43 239 1770 93.4 94.7 94.5 55 67 75 6322 6222350 261 3570 5007SY Custom 42 292 518 95.1 95.3 95.4 86 90 91 6314 6314350 261 1790 5011LY ECP50354L-2341 43 285 1111 94.3 95.1 95.4 83 88 89 6322 6222350 261 1185 5011LY ECP50356L-2341 46 300 1545 93.9 94.6 95.0 75 83 85 6324 6222350 261 890 5810 Custom 47 293 2065 94.2 95.1 95.0 74 80 83 6326 6322400 298 3570 5007SY ECP50402S-2341 48 332 587 94.8 95.5 95.4 86 91 91 6314 6314400 298 1790 5011LY ECP50404L-2341 50 323 1174 93.8 95.0 95.4 82 87 89 6322 6222400 298 1185 5011LY ECP50406L-2341 52 349 1765 93.9 94.8 95.0 74 82 86 6324 6222400 298 890 5810 Custom 54 351 2360 94.0 95.1 95.0 73 80 82 — —450 336 3580 5007SY Custom 55 558 660 95.0 95.6 95.4 88 90 92 6314 6314450 336 1790 5011LY ECP50454L-2341 56 364 1320 94.4 95.2 95.4 83 88 89 6322 6222450 336 1190 5011LY ECP50456L-2341 68 283 1985 93.7 95.0 95.4 60 70 75 6324 6222450 336 890 5810 Custom — — 2654 — — — — — — — —500 373 3570 5009SY ECP50502S-2341 60 401 734 95.4 96.0 95.8 87 90 92 6314 6314500 373 1790 5011LY ECP50504L-2341 60 386 1467 96.1 96.2 95.8 85 89 90 6322 6222500 373 1190 5011LY ECP50506L-2341 72 314 2204 93.9 95.2 95.4 59 69 75 6324 6222500 373 890 5810* Custom — — 2950 — — — — — — — —600 448 3570 5009SY* Custom 72 379 883 95.8 95.9 95.6 92 91 91 6314 6314600 448 1790 5011LY Custom 73 458 1760 94.1 95.1 95.4 88 90 90 6322 6222600 448 1185 5810 Custom 74 509 2645 94.6 95.5 96.2 80 85 89 6324 6322700 522 1785 5810 Custom 96 584 2343 93.9 94.8 95.4 91 92 92 6322 6322700 522 1185 5810* Custom 96 585 3081 95.1 95.8 95.9 71 75 79 6324 6322800 600 1785 5810* Custom 174 577 2343 95.0 95.2 95.4 90 91 92 6322 6322

TEFC NEMA Premium™ Efficiency 2300 or 4160 Volts, 60 Hz, 1.15 SF

*1.0 SFData subject to change without notice.

If data is not shown, contact a Baldor office. Contact a Baldor office for latest capabilities.

Page 18: Baldor Large Frame AC Induction Motorsucc.colorado.edu/baldor-reliance/BR435.pdf · 2 The best value in large motors, too. Years ago, when Baldor began making large frame AC motors

AMPS @ 460V RATED EFFICIENCY % POWER FACTOR % BEARINGSFULL LOCKED TORQUE FULL FULL

HP kW RPM FRAME CATALOG # LOAD ROTOR LB. FT. 1/2 3/4 LOAD 1/2 3/4 LOAD D.E. O.D.E.200 150 1785 447T M74204T-4 218 1448 588 95.0 95.5 95.4 80 88 90 6319 6314250 187 1785 449T M74254T-4 272 1774 736 94.8 95.6 95.4 79 87 90 6319 6314300 224 1785 449TY M74304T-4 328 2241 883 95.1 95.8 95.8 80 88 90 6319 6314

www.baldor.com17

Performance Data

TEBC Vector Drive Motors 460 Volts, 60 Hz, 1.0 SF

TEFC Explosion Proof 460 Volts, 60 Hz, 1.15 SF

ODP High Efficiency 460 Volts, 60 Hz, 1.15 SF

ODP/WPI High Efficiency, 2300/4160 V, 60 Hz, 1.15 SF

AMPS @ 460V RATED EFFICIENCY % POWER FACTOR % BEARINGSFULL LOCKED TORQUE FULL FULL MAX

HP kW RPM FRAME CATALOG # LOAD ROTOR LB. FT. 1/2 3/4 LOAD 1/2 3/4 LOAD D.E. O.D.E. Speed250 187 1780 449TC ZDM4408T-4 276 1720 740 93.9 94.9 95.8 79 86 89 6314 6319 2400300 224 1785 449TC ZDM44304T-4 333 2500 883 95.1 95.8 95.8 81 86 88 6314 6319 2400350 261 1785 449TC ZDM44354T-4 388 2750 1032 95.3 95.6 95.8 83 87 89 6314 6319 2400400 298 1785 5007L ZDM50404L-4 432 2766 1172 95.5 96.2 96.2 85 89 91 6222 6322 1800450 336 1790 5007L ZDM50454L-4 492 3075 1320 95.3 96.3 96.5 85 89 91 6222 6322 1800500 373 1790 5009L ZDM50504L-4 540 3487 1465 95.1 95.9 96.8 84 88 90 6222 6322 1800

AMPS @ 460V RATED EFFICIENCY % POWER FACTOR % BEARINGSFULL LOCKED TORQUE FULL FULL

HP kW RPM FRAME CATALOG # LOAD ROTOR LB. FT. 1/2 3/4 LOAD 1/2 3/4 LOAD D.E. O.D.E.400 298 3550 449TS M25402T-4 440 2544 591 94.8 94.5 93.6 85 89 91 6314 6314400 298 1780 449T M25404T-4 448 3110 1179 94.4 94.7 94.5 79 86 87 6321 6314450 336 3550 449TS M25452T-4 488 2900 663 95.2 95.0 94.1 85 89 91 6314 6314450 336 1780 449T M25454T-4 506 3200 1327 95.2 95.1 94.5 80 86 88 6321 6314500 373 3550 5009S M25502S-4 532 3459 732 95.4 96 95.8 82 88 90 6217 6217500 373 1780 5009L M25504L-4 582 3381 1467 95.2 95.5 95.8 80 82 85 6222 6222600 448 3550 5009S M25602S-4 652 4068 882 95.1 95.9 95.8 87 89 90 6217 6217600 448 1780 5009L M25604L-4 658 3476 1760 96.2 96.4 96.2 87 90 90 6222 6222

AMPS @ 4160V RATED EFFICIENCY % POWER FACTOR % BEARINGSFULL LOCKED TORQUE FULL FULL

HP kW RPM FRAME CATALOG # LOAD ROTOR LB. FT. 1/2 3/4 LOAD 1/2 3/4 LOAD D.E. O.D.E.300 224 3560 449T M25302T-2341 37 240 442 92.7 93.8 94.1 85 89 92 6314 6314300 224 1785 5009L M25304L-2341 38 224 883 94.1 94.6 94.5 82 87 89 6222 6222400 298 3580 5009S M25402S-2341 49 557 587 94 94.8 95 84 88 90 6217 6217400 298 1790 5009L M25404L-2341 52 329 1174 93.3 95.1 95 81 86 86 6222 6222500 373 3580 5009S M25502S-2341 61 401 735 95.2 95.6 95.4 85 88 90 6217 6217500 373 1790 5009L M25504L-2341 64 427 1468 93.7 94.5 95 82 85 87 6222 6222600 448 3580 5009S M25602S-2341 72 462 881 94.7 95.5 95.8 84 88 90 6217 6217600 448 1790 5009L M25604L-2341 76 416 1763 93.7 94.8 95.4 80 85 88 6222 6222

If data is not shown, contact a Baldor office. Data subject to change without notice.

Contact a Baldor office for latest capabilities.

Page 19: Baldor Large Frame AC Induction Motorsucc.colorado.edu/baldor-reliance/BR435.pdf · 2 The best value in large motors, too. Years ago, when Baldor began making large frame AC motors

www.baldor.com 18

Common Custom Motor Options

Electrical

• Bearing RTDs

• Winding RTDs , Thermistors or Thermostats

• Special Design C or D Windings

• Fabricated Copper Bar Rotors (5000 frame and up)

• Complete Electrical Tests, Heat Runs and Assorted Tests (Witnessed and Unwitnessed)

• Multi-speed Motors

• Surge Protection/lighting arrestors

• Various tests

Mechanical

• Metric Dimensions on Frame and Shaft

• Roller Bearing

• Renk® Sleeve Bearings

• Special Grease

• Larger Diameter Shaft

• Longer Shaft Length

• Double Shaft Extensions

• Space Heaters

• WPII Enclosure Hoods (5000 frame and up)

• API 541 and IEEE 841 Features

• Speed Feedback Devices

• Low audible noise designs available

5000 frame TEFC motor with Renk® sleeve bearings and RTD.

Motor Baldor Volume NEMA Minimum Volume NPT Frame Size In3 In3 Hole Size

444T/445T 600 600 2.5

445T/447T 600 600 2.5

447T/449T 1500 840 4

5005/5006/5007 2100 2000 4 (2)

5008/5009 2100 2000 4 (2)

5010/5011 2100 2000 4 (2)

5808/5809/5810/5812 3000 N/A 4 (3)

Conduit Box Volumes

Note: All Cast Iron construction. Lead separator gasket between box and frame is a neoprene rubber “cone” design for a water-tight seal around the lead wires. Conduit box lid gasket is neoprene rubber. Grounding provision is located inside the conduit box. Additional and/or larger conduit boxes are available.

Page 20: Baldor Large Frame AC Induction Motorsucc.colorado.edu/baldor-reliance/BR435.pdf · 2 The best value in large motors, too. Years ago, when Baldor began making large frame AC motors

www.baldor.com19

DimensionsODP 447T / 449T

NEMAFRAME A B C D E 2F H N O P U V AA AB BA447TS 21.5 28 44.38 11 9 20 & 25 .81 5.13 22.47 22.93 2.375 4.75 4-NPT 20.47 7.5447T 21.5 28 48.12 11 9 20 & 25 .81 8.87 22.47 22.93 3.375 8.5 4-NPT 20.67 7.5

449TS 21.5 28 44.38 11 9 20 & 25 .81 5.13 22.47 22.93 2.375 4.75 4-NPT 20.47 7.5449T 21.5 28 44.12 11 9 20 & 25 .81 8.87 22.47 22.93 3.375 8.5 4-NPT 20.67 7.5

NEMAFRAME A B C D E 2F H N-W O P U V AA AB AC BA5009S 30.06 36.40 51.75 12.50 10.00 22 & 25 & 28 0.94 6.75 28.32 38 2.500 6.50 4-NPT 27.87 21.90 8.505009L 30.06 36.40 56.62 12.50 10.00 22 & 25 & 28 0.94 11.62 28.32 38 3.875 11.12 4-NPT 28.50 22.50 8.505011S 30.06 43.40 59.75 12.50 10.00 32 & 36 0.94 6.75 28.32 38 2.500 6.50 4-NPT 28.75 22.75 8.505011L 30.06 43.40 64.62 12.50 10.00 32 & 36 0.94 11.62 27.57 38 3.875 11.12 4-NPT 28.75 22.75 8.505808S 35.50 38.63 54.25 14.50 11.50 22 & 25 & 28 1.18 6.75 33.25 44 3.375 6.50 4-NPT 32.00 25.88 9.755808L 35.50 38.63 60 14.50 11.50 22 & 25 & 28 1.18 12.50 33.25 44 4.125 9.00 4-NPT 32.00 25.88 9.755810S 35.50 44.63 62.25 14.50 11.50 28 & 32 & 36 1.18 6.75 33.38 44 3.375 6.50 4-NPT 32.00 25.88 9.755810L 35.50 44.63 68 14.50 11.50 28 & 32 & 36 1.18 12.50 33.38 44 4.875 9.00 4-NPT 32.00 25.88 9.75

C

D

E2F

H

N

V

O

P

U

AA

AB GREASE FITTING(EACH END)

EBA

B AAC

KEY

ODP / WPI 5000 / 5800C

LIFTINGPROVISIONS

2F

2F

BA

AIRIN

U

KEY

AIRIN

N-W

V

EE

A

ACH

4 NPTAA

1 NPT

D

O

AIROUT

P

AB2.81

Note: Drawings shown are for reference only. Please contact Baldor for a detailed dimensional drawing of the specific motor you require. Drawings may also be available from our CD-ROM or website at www.baldor.com.

Page 21: Baldor Large Frame AC Induction Motorsucc.colorado.edu/baldor-reliance/BR435.pdf · 2 The best value in large motors, too. Years ago, when Baldor began making large frame AC motors

www.baldor.com 20

DimensionsWPII 5000/5800

3.12

C

AIR EXHAUST

V

SOLID COVER

2F

2F

BA

N-W

U

P

AB

AIRINTAKE

Ø3.5

Ø2.0 O

D

HAC

A

2E

G

AA

4.7

2.81

Note: Drawings shown are for reference only. Please contact Baldor for a detailed dimensional drawing of the specific motor you require. Drawings may also be available from our CD-ROM or website at www.baldor.com.

NEMAFRAME A B C D E 2F H N-W O P U V AA AB AC BA5009S 30.06 36.40 54.88 12.50 10.00 22 & 25 & 28 0.94 6.75 51.75 30 2.500 6.50 4-NPT 28.50 22.50 8.505009L 30.06 36.40 59.75 12.50 10.00 22 & 25 & 28 0.94 11.62 51.75 30 3.875 11.12 4-NPT 28.50 22.50 8.505011S 30.06 43.40 62.88 12.50 10.00 32 & 36 0.94 6.75 51.75 32.13 2.500 6.50 4-NPT 29.50 22.00 8.505011L 30.06 43.40 67.75 12.50 10.00 32 & 36 0.94 11.62 51.75 32.13 3.875 11.12 4-NPT 29.50 22.00 8.505808S 35.50 38.63 57.37 14.50 11.50 22 & 25 & 28 1.18 6.75 60 39 3.375 6.50 4-NPT 33.31 27.20 9.755808L 35.50 38.63 63.0 14.50 11.50 22 & 25 & 28 1.18 11.25 60 39 4.125 9.00 4-NPT 33.31 27.20 9.755810S 35.5 44.63 65.37 14.50 11.50 28 & 32 & 36 1.18 6.75 60 39 3.375 6.50 4-NPT 33.31 27.20 9.755810L 35.5 44.63 71.0 14.50 11.50 28 & 32 & 36 1.18 11.25 60 39 4.875 9.00 4-NPT 33.31 27.20 9.75

Page 22: Baldor Large Frame AC Induction Motorsucc.colorado.edu/baldor-reliance/BR435.pdf · 2 The best value in large motors, too. Years ago, when Baldor began making large frame AC motors

www.baldor.com21

NEMAFRAME A B C D E 2F H N O P U V AA AB BA447TS 21.75 23.75 44.00 11.00 9.00 16.5 & 20 0.81 6.44 22.94 24.56 2.375 4.75 3 NPT 20.57 7.50447T 21.75 23.75 47.75 11.00 9.00 16.5 & 20 0.81 8.93 22.94 24.56 3.375 8.50 3 NPT 20.43 7.50

449TS * 21.75 28.75 48.90 11.00 9.00 20 & 25 0.81 4.93 22.94 24.56 2.375 4.75 4-NPT 21.71 7.50449TS 21.75 28.75 48.90 11.00 9.00 20 & 25 0.81 5.19 22.94 24.56 2.375 4.75 4-NPT 21.71 7.50449T 21.75 28.75 52.65 11.00 9.00 20 & 25 0.81 8.94 22.94 24.56 3.375 8.50 4-NPT 21.71 7.50

449TY 21.75 28.75 54.35 11.00 9.00 20 & 25 0.81 9.11 22.94 24.56 3.375 8.50 4-NPT 21.71 8.50

TEFC 447T / 449T

SLINGER

V

2F

B

BA NH

KEY

U

O

D

ABGREASER & RELIEF

(EACH END)

P

AC

E E

A

AA

C

TEFC 5000C

3/4 NPT

H 2F

B

BA

N-W

V

U

AA EACA

AB

P

D

O

2NPT

Note: Drawings shown are for reference only. Please contact Baldor for adetailed dimensional drawing of the specific motor you require. Drawings mayalso be available from our CD-ROM or website at www.baldor.com.

*2-pole only, Design has shaft end bearing cooling fan

NEMAFRAME Poles A B C D E 2F H N-W O P U V AA AB BA5007SY 2 25.65 28.4 54.03 12.50 10.00 18 & 20 & 22 0.94 6.75 26.84 29.90 2.500 6.50 4-NPT 26.88 9.875007L 4 & 6 25.65 28.4 56.93 12.50 10.00 18 & 20 & 22 0.94 11.62 26.84 29.90 3.875 11.12 4-NPT 26.88 8.50

5009SY 2 25.65 34.4 60.03 12.50 10.00 25 & 28 0.94 6.75 26.84 29.90 2.500 6.50 4-NPT 26.88 9.875009L 4 & 6 25.65 34.4 62.93 12.50 10.00 25 & 28 0.94 11.62 26.84 29.90 3.875 11.12 4-NPT 26.88 8.505011LY 4 & 6 25.65 42.4 72.05 12.50 10.00 32 & 36 0.94 11.54 26.84 29.90 3.875 11.12 4-NPT 26.88 9.71

Dimensions

Page 23: Baldor Large Frame AC Induction Motorsucc.colorado.edu/baldor-reliance/BR435.pdf · 2 The best value in large motors, too. Years ago, when Baldor began making large frame AC motors

www.baldor.com 22

DimensionsTEFC 5800

C

B

BA2FH N-W

V

KEY

U

4 NPTAA

E E

AC

A

1 NPT

P

D

O

AB

TEBC Inverter/Vector

4.7AA HOLE AC E 1.44

2CA

AB42.5 REF.

P

46.9

G

VOLUME160 IN 3

2-NPT

1/4 DIA.TYP. 4

N-WV

U

C

BA3.79

2FB

17.59

9.65

H HOLEENCODER MTG.(OPPOSITE SIDE)

1/2 NPTC/BOX FOR

BLOWER MOTOR

NEMAFRAME A B C D E 2F H N-W O P U V AA AB AH AJ AK BA BB BD TAP449TC* 21.75 28.75 64.37 11.00 9.00 20 & 25 0.81 24.55 24.55 3.375 8.5 4-NPT 21.71 8.25 14.00 16.00 7.50 0.25 16.75 5/8-115007L 25.65 28.40 68.06 12.50 10.00 18 & 20 & 22 0.94 11.62 26.84 29.90 3.875 11.12 4-NPT 26.88 8.505009L 25.65 34.40 74.05 12.50 10.00 25 & 28 0.94 11.62 26.84 29.90 3.875 11.12 4-NPT 26.88 8.505011LY 25.60 42.40 85.87 12.50 10.00 32 & 36 0.94 11.54 26.84 29.90 3.875 11.12 4-NPT 26.88 9.715810 32.00 42.40 87.96 14.50 11.50 28 & 32 & 36 1.18 12.50 34.00 33.00 4.125 11.00 4-NPT 30.19 11.385812 32.00 51.40 95.96 14.50 11.50 40 & 45 1.18 12.50 34.00 33.00 4.125 11.00 4-NPT 30.19 11.38

Note: Drawings shown are for reference only. Please contact Baldor for a detailed dimensional drawing of the specific motor you require. Drawings may also beavailable from our CD-ROM or website at www.baldor.com.

NEMAFRAME A B C D E 2F H N-W O P U V AA AB AC BA

5810 32.00 42.40 75.18 14.50 11.50 28 & 32 & 36 1.18 12.50 34.00 33.00 4.125 11.00 4-NPT 30.19 24.50 11.385812 32.00 51.40 81.77 14.50 11.50 40 & 45 1.18 9.00 34.00 33.00 4.125 8.75 4-NPT 30.19 24.50 11.84

* Only 449TC stock motor designs have frame with standard C-face

Page 24: Baldor Large Frame AC Induction Motorsucc.colorado.edu/baldor-reliance/BR435.pdf · 2 The best value in large motors, too. Years ago, when Baldor began making large frame AC motors

www.baldor.com23

TEFC Explosion Proof 449T

H B

2FBA

U

KEY

NV

C

GREASE RELIEF(EACH END)

E E

ACA

AA

O

D

AB

P

NEMAFRAME A B C D E 2F H-W N O P U V AA AB BA

445TS 21.75 20.25 40.50 11.00 9.00 14.5 & 16.5 0.81 4.90 22.91 24.81 2.375 4.75 3-NPT 23.6 7.50

445T 21.75 20.25 44.25 11.00 9.00 14.5 & 16.5 0.81 8.75 22.91 24.81 3.375 8.50 3-NPT 23.6 7.50

449TS 21.75 28.75 49.00 11.00 9.00 20 & 25 0.81 4.94 22.94 24.81 2.375 4.75 3-NPT 27.67 7.50

449T 21.75 28.75 52.75 11.00 9.00 20 & 25 0.81 8.72 22.94 24.81 3.375 8.50 3-NPT 27.67 7.50

449TY 21.75 28.75 54.25 11.00 9.00 20 & 25 0.81 8.72 22.94 24.81 3.375 8.50 3-NPT 27.67 9.00

Limited WarrantyThree years on Super-E®, 24 months on Standard-E™, 18 months on most other motors, 5 years on IEEE841.

Note: Drawings shown are for reference only. Please contact Baldor for a detailed dimensional drawing of the specific motor you require. Drawings may also be available from our CD-ROM or website at www.baldor.com.

Dimensions

Page 25: Baldor Large Frame AC Induction Motorsucc.colorado.edu/baldor-reliance/BR435.pdf · 2 The best value in large motors, too. Years ago, when Baldor began making large frame AC motors

www.baldor.com 24

OPTIONAL T'STATS LOW VOLTAGE HIGH VOLTAGEP1

P25

8

23

6 9

74

1

7 8 9

1 2 3

4 5 6

3217 8 9

4 5 6

LINELINE

2Y 1Y

9 Lead Wye-Connected Motor

NEMA Standard Lead Markings

Connection Diagrams Main Motor Power Leads

OPTIONAL T'STATSP1

24 7

58

3

P2

96

1LOW VOLTAGE

(2D)HIGH VOLTAGE

(1D)7 8 9

6 4 5

1 2 3

7 8 9

4 5 6

1 2 3

LINE LINE

TYPICAL WYE- CONNECTED MOTOR

OPTIONAL T'STATS

1 2 3

LINE

TYPICAL DELTA - CONNECTED MOTOR

OPTIONAL T'STATS

P1

21

3P2

23

1 P1

P2

9 Lead Delta-Connected Motor

3 Lead

Notes:1. Three lead motors may be designed as either wye-connected or delta-connected.2. Interchange any two line leads to reverse rotation.3. Optional thermostats are provided when specified.4. Actual number of internal parallel circuits may vary.

Lead Marking MotorPower Leads T1, T2, T3, etc.Thermostat P1, P2, etc.

Space Heater H1, H2, H3, H4, etc.Winding Resistance Temperature R1, R2, R3, R4, etc.

Detector (RTD)

Page 26: Baldor Large Frame AC Induction Motorsucc.colorado.edu/baldor-reliance/BR435.pdf · 2 The best value in large motors, too. Years ago, when Baldor began making large frame AC motors

www.baldor.com25

Mod-Express™

VVibration Levelsibration LevelsVibration levels are in accordance with NEMA MG-1 section 12.06.

In addition to the Chemical Processing motors shown in this brochure that are available from stock,customized motors are available for special requirements on OEM applications. Baldor’s short lead times can supply the motor for your specific application with special voltage, base speed, Design C torque, C-Face,D-Flange, IEC metric dimensions, or other application-based needs. Special motors are in use on mixers,aerators, crushers, centrifuges, hoists, pumps, and HVAC equipment.

Motors may be taken from Baldor’s Fort Smith inventory and modified through our Mod-Express™ program.These modifications include:

• Dynamic Balance of Rotor

• Inpro® Seal

• F-2 Conversion

• Special Performance Tests

• Roller Bearings

• Bearing Thermocouples, Thermistors or RTD’s

• Space Heaters

• Winding Thermocouples, Thermistors or RTD’s

Encoder Receptacle Connections For Vector Drive Motors

PIN FUNCTIONA AB BC Z(C)D VDC (5-15 VDC Standard)E ShieldF Circuit GroundG Case GroundH A Compliment (A)J B Compliment (B)K Z (C) Compliment (Z or C)

Standard Receptacle MS3112E12-10P (Baldor Part # WD1434)Standard Plug MS3116J12-10S (Baldor Part # WD1435)

Both receptacle and plug are provided with the motor. Note that together these connections are weatherproof.

F

E

A

B

C

D

G

HJK

Page 27: Baldor Large Frame AC Induction Motorsucc.colorado.edu/baldor-reliance/BR435.pdf · 2 The best value in large motors, too. Years ago, when Baldor began making large frame AC motors

www.baldor.com 26

Page 28: Baldor Large Frame AC Induction Motorsucc.colorado.edu/baldor-reliance/BR435.pdf · 2 The best value in large motors, too. Years ago, when Baldor began making large frame AC motors

Baldor Electric CompanyP.O. Box 2400

Fort Smith, AR 72902-2400 U.S.A.Ph (479) 646-4711 • Fax (479) 648-5792

International Fax (479) 648-5895www.baldor.com

© Baldor Electric CompanyBR435

Printed in U.S.A.9/03 PROG 30,000

Contact your nearest Baldor District Office at these World Wide locations, or visit www.baldor.com

UNITED STATES

ARIZONAPHOENIX4211 S 43RD PLACEPHOENIX, AZ 85040PH: 602-470-0407FAX: 602-470-0464

CALIFORNIALOS ANGELES6480 FLOTILLACOMMERCE, CA 90040PH: 323-724-6771FAX: 323-721-5859

HAYWARD21056 FORBES STREETHAYWARD, CA 94545PH: 510-785-9900FAX: 510-785-9910

COLORADODENVER2520 W BARBERRY PL.DENVER, CO 80204PH: 303-623-0127FAX: 303-595-3772

CONNECTICUTWALLINGFORD65 SOUTH TURNPIKE RDWALLINGFORD, CT 06492PH: 203-269-1354FAX: 203-269-5485

FLORIDATAMPA/PUERTO RICO/VIRGIN ISLANDS3906 EAST 11TH AVETAMPA, FL 33605PH: 813-248-5078FAX: 813-247-2984

GEORGIAATLANTA62 TECHNOLOGY DR. ALPHARETTA, GA 30202PH: 770-772-7000FAX: 770-772-7200

ILLINOISCHICAGO795 MITTEL DRIVEWOOD DALE, IL 60191PH: 630-787-9600FAX: 630-787-0434

INDIANAINDIANAPOLIS5525 W. MINNESOTA STINDIANAPOLIS, IN 46241 PH: 317-246-5100FAX: 317-246-5110800-428-4141

IOWADES MOINES1901 BELL AVENUE, SUITE 7DES MOINES, IA 50315PH: 515-244-9996FAX: 515-244-6124

MARYLANDBALTIMORE6660 SANTA BARBARA RD.SUITE 22-24ELKRIDGE, MD. 21075PH: 410-579-2135FAX: 410-579-2677

MASSACHUSETTSBOSTON317 BROOKS ST.WORCESTER, MA 01606PH: 508-854-0708FAX: 508-854-0291

MICHIGANDETROIT33782 STERLING PONDS BLVD.STERLING HEIGHTS, MI 48312PH: 586-978-9800FAX: 586-978-9969

GRAND RAPIDS668 3 MILE ROAD NWGRAND RAPIDS, MI 49504PH: 616-785-1784FAX: 616-785-1788

MINNESOTAMINNEAPOLIS21080 134TH AVE. N.ROGERS, MN 55374PH: 763-428-3633FAX: 763-428-4551

MISSOURIST LOUIS422 INDUSTRIAL DRIVEMARYLAND HEIGHTS, MO 63043PH: 314-298-1800FAX: 314-298-7660

KANSAS CITY915 NW PLATTE VALLEY DRRIVERSIDE, MO 64150PH: 816-587-0272FAX: 816-587-3735

NEW YORKAUBURNONE ELLIS DRIVEAUBURN, NY 13021PH: 315-255-3403FAX: 315-253-9923

NORTH CAROLINAGREENSBORO1220 ROTHERWOOD RDGREENSBORO, NC 27406PH: 336-272-6104FAX: 336-273-6628

OHIOCINCINNATI2900 EARHART COURTSUITE 200HEBRON, KY 41048PH: 859-586-0222FAX: 859-586-0779

CLEVELAND8929 FREEWAY DRIVEMACEDONIA, OH 44056PH: 330-468-4777FAX: 330-468-4778

OKLAHOMATULSA2 EAST DAWES BIXBY, OK 74008PH: 918-366-9320FAX: 918-366-9338

OREGONPORTLAND20393 SW AVERY CRTTUALATIN, OR 97062PH: 503-691-9010FAX: 503-691-9012

PENNSYLVANIAPHILADELPHIA1035 THOMAS BUSCH MEMORIAL HIGHWAYPENNSAUKEN, NJ 08110PH: 856-661-1442FAX: 856-663-6363

PITTSBURGH616H BEATTY ROADMONROEVILLE, PA 15146PH: 412-380-7244FAX: 412-380-7250

TENNESSEEMEMPHIS4000 WINCHESTER RDMEMPHIS, TN 38118PH: 901-365-2020FAX: 901-365-3914

TEXASHOUSTON4647 PINE TIMBERSSUITE # 135HOUSTON, TX 77041PH: 713-895-7062FAX: 713-690-4540

DALLAS3040 QUEBECDALLAS, TX 75247PH: 214-634-7271FAX: 214-634-8874

ODESSA6968 EAST COMMERCEODESSA, TX 79762PH: 915-367-2707FAX: 915-367-9877

UTAHSALT LAKE CITY70 WEST SENIOR WAYSALT LAKE CITY, UT 84115PH: 801-973-6363FAX: 801-973-6301

WISCONSINMILWAUKEE2725 SOUTH 163RD STNEW BERLIN, WI 53151PH: 262-784-5940FAX: 262-784-1215

INTERNATIONAL SALESFORT SMITH, ARBALDOR ELECTRIC COFORT SMITH, AR 72902PH: 479-646-4711FAX: 479-648-5895

CANADAEDMONTON, ALBERTA4053-92 STREETEDMONTON, ALBERTA

T6E6R8PH: 780-434-4900FAX: 780-438-2600

OAKVILLE, ONTARIO2750 COVENTRY ROADOAKVILLE, ONTARIO L6H6R1PH: 905-829-3301FAX: 905-829-3302

MONTREAL, QUEBEC1844 WILLIAM STREETMONTREAL, QUEBEC H3J1R5PH: 514-933-2711FAX: 514-933-8639

VANCOUVER, BRITISH COLUMBIA1538 KEBET WAYPORT COQUITLAM, BC V3C 5M5PH 604-421-2822FAX: 604-421-3113

WINNIPEG, MANITOBA54 PRINCESS STREETWINNIPEG, MANITOBA R3B1K2PH: 204-942-5205FAX: 204-956-4251

AUSTRALIAUNIT 3, 6 STANTON RDSEVEN HILLS, NSW 2147 AUSTRALIAPH: (61)(2)9674 5455FAX: (61)(2)9674 2495

UNIT 3-73 MAIN ROADCLAYTON VIC 3168, AUSTRALIAPH: (61)(3)5624555FAX: (61)(3)5624822

CHINASHANGHAI JIAHUA BUSINESS CENTERROOM NO. C-203808 HONG QIAO ROADSHANGHAI 200021PH: 86-21-64473060FAX: 86-21-64078620

EL SALVADORBALDOR RESIDENCIALPINARES DE SUIZA POL. 15 #44, NVA. SAN SALVADOR EL SALVADOR,

CENTRO AMERICAPH: (503) 288-1519FAX: (503) 288-1518

FRANCE2, RUE DU VALLON 94440 MAROLLES EN BRIEPH: 33 145 10 7902FAX: 33 145 99 0864

GERMANYDIESELSTRASSE 22D-85551 KIRCHHEIM MUNICH, GERMANYPH: (49) (89) 90508-0FAX: (49) (89) 90508-491

ITALYBALDOR ASR AGMENDRISIO OFFICEVIA BORROMINI, 20A6850 MENDRISIOSWITZERLANDPHONE: 0041 91 640 99 50FAX: 0041 91 630 26 33

JAPANNEO MIME 5012-5 DAIMACHI, KANAGAWA-KUYOKOHAMA, 221-0834, JAPAN PH: 81-45-412-4506

FAX: 81-45-412-4507MÉXICO

BLVD. AL AEROPUERTO, KM. 2 LEÓN 37545, GUANAJUATO, MÉXICOPH: 52-477-761-2030FAX: 52-477-761-2010

PANAMABALDOR SUDAMERICA9109 0818, ZONA 6 BETHANIAPANAMÁ CITY, REP. DE PANAMÁPH: (507) 261-5347FAX: (507) 261-5355

PHILIPPINESROOM 604, WEB-JET ACROPOLIS BLDG.8120 E. RODRIGUEZ AVENUEBAGUMBAYAN, QUEZON CITYPHILIPPINESPH: (632) 638-2241FAX: (632) 638-2243

SINGAPORE51 KAKI BUKIT ROAD 2K B WAREHOUSE COMPLEXSINGAPORE 417863PH: (65) 6 744 2572FAX: (65) 6 747 1708

SWITZERLANDPOSTFACH 73SCHUTZENSTRASSE 59CH-8245 FEUERTHALENSWITZERLANDPH: (41) (52) 6474700FAX: (41) (52) 6592394

TAIWANROOM R, 2F, NO. 124 CHUNG CHENG ROAD, SHIHLIN DIST.TAIPEI 11141PH: 886-2-2835-1666 EXT. 802 FAX: 886-2-2835-1717

UNITED KINGDOM6 BRISTOL DISTRIBUTION PARKHAWKLEY DRIVEBRISTOL BS32 0BF U.K.PH: 44 1454 850000FAX: 44 1454 859001