ANALISA PENGARUH TUBE PLUGGING TERHADAP PERFOMANSI LUBE OIL COOLER PADA GAS TURBINE BLOK 1.1 DI PLTGU GRESIK
Nama : Yananda Radyo Harlistyo (2110 038 004)
Progam Studi D3 Teknik Mesin Fakultas Teknologi Industri
Institut Teknologi Sepuluh Nopember Surabaya
2013
Dosen Pembimbing : Hendro Nurhadi, Dipl, -Eng, Ph.D
LATAR BELAKANG
Gambaran umum PT PJB UP Gresik
Unit unit PT PJB UP Gresik
PLTG PLTU
PLTGU
Gas Turbine 1.1
Gas Turbine 1.2
Gas Turbine 1.3
Gas Turbine 2.1
Gas Turbine 2.2
Gas Turbine 2.3
Gas Turbine 3.1
Gas Turbine 3.2
Gas Turbine 3.3
Steam Turbine 1
Steam Turbine 2
Steam Turbine 3
HRSG 1.1
HRSG 1.2
HRSG 1.3
HRSG 2.1
HRSG 2.2
HRSG 2.3
HRSG 3.1
HRSG 3.2
HRSG 3.3
BLOK 3
BLOK 1
BLOK 2
LATAR BELAKANG
Pembagian unit Gas Turbine dan Steam Turbine pada tiap blok PLTGU Gresik
Lube Oil Cooler
LATAR BELAKANG
Lube Oil Sytem Gas Turbine
Permasalahan yang terjadi di Lube Oil Cooler adalah terjadi kebocoran pada tube
Kebocoran pada tube ditanggulangi dengan di-plug
Plugging tube akan mempengaruhi terhadap perfomansi pada Lube Oil Cooler
Gambar Skema Plugging Tube
LATAR BELAKANG
Latar Belakang
1. Bagaimana pengaruh plugging terhadap perfomansi Lube Oil Cooler
2. Berapa batas plugging optimum yang di izinkan
RUMUSAN MASALAH DAN TUJUAN
Rumusan Masalah
Tujuan 1. Mengetahui perfomansi Lube Oil Cooler dengan pengaruh
plugging
2. Mengetahui batas plugging optimum yang diizinkan
1. Heat exchanger yang dianalisa adalah yang digunakan sebagai Lube Oil Cooler pada Gas Turbine 1.1 di PLTGU Gresik
2. Lube oil cooler merupakan heat exchanger bertipe shell and tube heat exchanger
3. Fluida yang digunakan pada bagian tube adalah cooling water
4. Fluida yang digunakan pada bagian shell adalah lube oil
5. Kondisi operasi diasumsikan steady state
6. Posisi plugging diasumsikan tidak berpengaruh terhadap koefisien perpindahan panas di sisi shell
7. Penempatan plug diasumsikan secara acak
8. Perpindahan panas yang terjadi secara konveksi dan konduksi serta mengabaikan pengaruh perpindahan panas radiasi
9. Perpindahan panas yang terjadi pada tube yang telah di-plug tidak di hitung
10. Analisa ekonomi tidak diperhitungkan
11. Fouling faktor diabaikan (Rf=0)
BATASAN MASALAH
Batasan Masalah
Flowchart Tugas Akhir Mulai
Perumusan Masalah
Pengambilan data
Analisa Perhitungan Teknik
Kesimpulan
Selesai
A
A
Apakah plugging optimum
YA
TIDAK
Studi Literatur
METODOLOGI PENELITIAN
Diameter dalam tube : 14,63 mm Diameter luar tube : 15,88 mm Panjang tube : 3150 mm
Jumlah tube : 984 tube Jumlah laluan tube : 4 pass Material tube : Aluminium Brass
Allowable pressure drop tube : 0,5 kg/cm2 Allowable pressure drop shell : 0,8 kg/cm2
Lube Oil Cooler
METODOLOGI PENELITIAN
Spesifikasi Lube OiL Cooler
ANALISA DATA DAN PEMBAHASAN
Control Volume Lube Oil Cooler
Inlet Cooling Water
Outlet Cooling Water
Outlet Lube Oil
Inlet Lube Oil
,
, ,
,
Cooling water
Kapasitas (Qc) 200 m3/hr
Inlet Temperature (Tc,i) 43 oC
Outlet Temperatur (Tc,o) 49 oC
Lube Oil
Kapasitas (Qh) 186 m3/hr
Inlet Temperature (Th,i) 75 oC
Outlet Temperature(Th,o) 60 oC
Data data yang diketahui
ANALISA DATA DAN PEMBAHASAN
Data data yang diketahui
ANALISA DATA DAN PEMBAHASAN
B
Dimensi
Diameter luar tube (do) 15,88 mm
Diameter dalam tube (di) 14,64 mm
Panjang tube (L) 3150 mm
Jumlah tube (Nt) 984 tube
Jumlah laluan (Np) 4 laluan
Diameter dalam shell (ID) 790 mm
Jarak transversal (ST) 22 mm
Jarak antar baffle (B) 240 mm Dimensi sisi tube
Dimensi tube staggered
ID
ANALISA DATA DAN PEMBAHASAN
Mencari properties lube oil dan cooling water Temperatur rata-rata lube oil :
, = (348 + 333) 02 = 340,5 Temperatur rata-rata cooling water: , = (322 + 316) 2 = 319
Lube Oil
Density (o) 859,6 kg/m3
Specific Heat (Cpo) 2.078,1 J/kg K
Viskositas kinematik (o) 5222,5 x 10-5 Ns/m2
Koefisien konduksi (ko) 139,05 x 10-3 W/m K
Prandlt Number (Pr) 780,65
Cooling Water
Density (c) 989,511 kg/m3
Specific Heat (Cpc) 4.179,8 J/kg K
Viskositas kinematik (c) 587,8 x 10-6 Ns/m2
Koefisien konduksi (kc) 638,8 x 10-3 W/m K
Prandlt Number (Pr) 3,848
Perhitungan variasi plugging 0 30 %
ANALISA DATA DAN PEMBAHASAN
Contoh perhitungan plugging 30 % 1. Mencari jumlah tube yang aktif
= 100% = 100% 30% 984 = 689
Reynold Number
= = 989,511 3 1,916 0,01464 0,0005878
2
= 47.214,964
ANALISA DATA DAN PEMBAHASAN
Perhitungan di sisi tube Kecepatan Cooling water
= 14 2 = 4 0,056314 0,0146422 689 = 1,916 Nusselt Number = 0,0234 5
= 0,023 47.214,9644 5 3,8480,4 = 216,314
Koefisien Konveksi
= = 216,314 0,6388 0,01464 = 9.438,64 2
Dimensi sisi tube
ANALISA DATA DAN PEMBAHASAN
Pressure drop sisi tube Koefisien gesek tube = 0,79 1,64 2 = [0,79 47.214
1,64]2 = 0,0212
Head loss mayor
, = 22 ,= 0,0212 4 3,15 0,01464 1,9162 22(2) 9,81
2
, = 3,42
Head loss minor
. = 22 . = 4(1 + 0,5) 1,9162 222 9,81
2
. = 1,12 Head loss total , = , + , , = (3,42 + 1,12) , = 4,54
Pressure drop tube = , = 4,54 989,511 2 21000 2 = 0,44 2
ANALISA DATA DAN PEMBAHASAN
Perhitungan sisi shell Cross Flow Area
= = 0,79 (0,022 0,01588) 0,39 0,022 = 0,044 Kecepatan lube oil
= = 0,052 30,044 = 1,176
Kecepatan maksimum A1
= = 0,022 0,022 0,01588 1,176 = 3,514
Dimensi Tube Staggered
Menentukan kecepatan di A1 atau A2
A
Perhitungan sisi shell
ANALISA DATA DAN PEMBAHASAN
Nusselt Number
= 1 , 0,36 1 4 = 0,9 918,4120,4 780,650,36 780,651205 1 4 = 136,022
Reynold Number
, = , = 859,6 3 3,514 0,01588 0,052225
2
, = 918,412
Koefisien konveksi
= = 136,022 0,13905 0,01588 = 1.191,049
A
Pressure drop sisi shell
ANALISA DATA DAN PEMBAHASAN
Konversi satuan
,= 68.219,045 2 29,81 210002 ,= 0,695 2
Pressure drop sisi shell
,= 22 ,= 20 0,8 859,6 3 3,5142 222 0,8 ,= 68.219,045 2
ANALISA DATA DAN PEMBAHASAN
Perhitungan Overall heat transfer
Overall heat transfer
= 1
+ 2 + 1 = 10,01588 9.438,64
2 0,01464 + 0,01588 0,01588 0,01464 2 238,845 + 11.191,049 2
= 1.044,692 2
ANALISA DATA DAN PEMBAHASAN
Perhitungan NTU - Effectiveness
Kapasitas panas cooling water = , = , = 989,511 3 0,0563 4179,8 = 229.775,449 Kapasitas panas lube oil = , = , = 859,6 3 0,0523 2078,1 = 92.293,963
Menentukan Cmin Cc > Ch
Maka Cmin = Ch
B
Kapasitas ratio
= = 92.293,963 229.775,449 = 0,402
ANALISA DATA DAN PEMBAHASAN
Perhitungan NTU - Effectiveness
Number of Transfer Unit
=
= 1.044,692 2 14 0,0158822 68992.293,963 = 1,226
Effectiveness
= 2 1 + 1 + 2 1 2 1+ 1+ 1 21 1+ 1 2 1 = 2 1 + 0,402 1 + 0,4022 1 2 1 + 1,226 1 + 0,402 1 21 1,226 1 + 0,402 1 2 1 = 0,467
B
ANALISA DATA DAN PEMBAHASAN
Hasil perhitungan NTU Effectiveness variasi plugging 0 - 30% M Vc
(m/s) hi
(W/m2 K) NTU p,tube
(kg/cm2)
0% 1,341 7.095,579 1,662 0,576 0,23
5% 1,410 7.392,800 1,589 0,560 0,26
10% 1,487 7.719,583 1,515 0,524 0,28
15% 1,573 8.080,769 1,440 0,505 0,32
20% 1,676 8.482,344 1,364 0,484 0,35
25% 1,788 8.931,797 1,287 0,462 0,40
30% 1,916 9.438,640 1,209 0,439 0,45
0,20
0,25
0,30
0,35
0,40
0,45
0,50
0,500
0,700
0,900
1,100
1,300
1,500
1,700
1,900
2,100
0% 10% 20% 30%
pt
ube
(kg/
cm2)
Vtu
be (
m/s
)
Plugging
Pengaruh plugging terhadap Vtube, dan Ptube
kecepatan tube pressure drop tube
0,400
0,420
0,440
0,460
0,480
0,500
0,520
0,540
0,560
0,580
0,600
1,000 1,200 1,400 1,600 1,800
Effe
ctiv
enes
s (
)
NTU
NTU -
NTU - Effectiveness
ANALISA DATA DAN PEMBAHASAN
Grafik hasil perhitungan NTU - Effectiveness
0% plugging
ANALISA DATA DAN PEMBAHASAN
Perhitungan temperatur keluar lube oil dan cooling water Laju perpindahan panas maksimum = , , = 92.293,963 348 316 = 2.953.406,803 Laju perpindahan panas aktual =
= 0,462 2.953.406 = 1.364.337,441
Temperatur keluar cooling water = , , , , = , + , , = 1.364.337,441 54,973 4179,8 + 316 , = 322,598 273 , = 48,94
Temperatur keluar lube oil = , , , , = , , , = 1.565.045,404 44,413 2078,1 + 348 , = 331,04 273 , = 60,22
M Th,o (oC) Tc,o (oC)
0% 56,56 50,46
5% 57,08 50,20
10% 57,63 49,98
15% 58,22 49,74
20% 58,84 49,49
25% 59,51 49,22
30% 60,22 48,94
48,80
49,00
49,20
49,40
49,60
49,80
50,00
50,20
50,40
50,60
56,00
56,50
57,00
57,50
58,00
58,50
59,00
59,50
60,00
60,50
0% 10% 20% 30%
Tc,o
(0C
)
Th,o
(oC
)
Plugging
Pengaruh Plugging terhadap Temperatur Keluar Lube Oil dan Cooling Water
Th out Tc out
ANALISA DATA DAN PEMBAHASAN
Hasil perhitungan temperatur keluar lube oil dan cooling water variasi plugging 0 - 30 %
KESIMPULAN
Kesimpulan
1. Semakin banyak tube yang di-plug maka effectiveness akan semakin menurun sedangkan pressure drop dan kecepatan di sisi tube akan meningkat
2. Batasan optimum plugging sebesar 25% dengan menggunakan analisa perhitungan teknik
1. Menggunakan software Fluent dengan model 3D untuk mendapatkan hasil yang lebih akurat.
2. Referensi (baik manual book maupun jurnal) yang khusus membahas tentang pengaruh tube plugging pada Lube Oil Cooler jumlahnya sangat kurang. Oleh karena itu perlu adanya penelitian lebih lanjut tentang Lube Oil Cooler.
Saran
ANALISA PENGARUH TUBE PLUGGING TERHADAP PERFOMANSI LUBE OIL COOLER PADA GAS TURBINE BLOK 1.1 DI PLTGU GRESIKSlide Number 2Slide Number 3Slide Number 4Slide Number 5Slide Number 6Slide Number 7Flowchart Tugas AkhirSlide Number 9Slide Number 10Slide Number 11Slide Number 12Slide Number 13Slide Number 14Slide Number 15Slide Number 16Slide Number 17Slide Number 18Slide Number 19Slide Number 20Slide Number 21Slide Number 22Slide Number 23Slide Number 24Slide Number 25Slide Number 26Slide Number 27Slide Number 28