32
LIM GUOWEI UK20669 YONG HIONG SIENG UK20711 KHAIRUN NAIM BIN TAHIR UK20569 ZAKWAN BIN DERAMAN UK20936 FRESHWATER GENERATOR Department of Maritime Technology, Faculty of Maritime Studies and Marine Science, Universiti Malaysia Terengganu. G ROUP B1

B1 Freshwater Generator

Embed Size (px)

Citation preview

Page 1: B1 Freshwater Generator

LIM GUOWEI UK20669YONG HIONG SIENG UK20711KHAIRUN NAIM BIN TAHIR UK20569ZAKWAN BIN DERAMAN UK20936

FRESHWATERGENERATOR

Department of Maritime Technology, Faculty of Maritime Studies and Marine Science, Universiti Malaysia Terengganu.

GROUP B1

Page 2: B1 Freshwater Generator

Presentation Outlinei. Introductionii. Operationiii. Typesiv. Construction

Freshwater Generator

Page 3: B1 Freshwater Generator

By

YONG HIONG SIENG

Page 4: B1 Freshwater Generator

INTRODUCTIONFunction

?Why we need

distilled water

?Naming

Variation

?TDS

?

In Practice

?

Page 5: B1 Freshwater Generator

Functions To produce high-purity distilled water from

seawater. To produce distilled water from raw

freshwater supplies of insufficient or doubtful purity.

Water for boiler; Portable water for drinking, cooking,

dishwashing, ablutionary, hospital and laundry.

Why we need distilled water ?

Page 6: B1 Freshwater Generator

Naming Variation

Distilling plant; evaporator; distiller; distillation system; desalinator

Seawater Distillate

Total dissolved solids (TDS) = 32000 mg/litre

TDS less than 500 mg/litre

Page 7: B1 Freshwater Generator

T D S to know Portable water for crew requirements

contains less than 500 mg/litre of suspended solids.

Good quality boiler feed will contain less than 2.5 mg/litre.

Thus, the portable water taken from port is not suitable for use in water tube boilers.

Page 8: B1 Freshwater Generator

In Practice It is a statutory requirement that ocean-going

(foreign) ships should carry distillation plant for emergency use even if sufficient portable water for normal requirement is carried.

So, people take only a minimum supply of portable water and make-up the rest by distillation of sea water.

A freshwater generator should be capable of operating for a period of at least 90 days at rated capacity without shutdown for cleaning.

Page 9: B1 Freshwater Generator

By

KHAIRUN NAIM BIN TAHIR

Page 10: B1 Freshwater Generator

FRESHWATER GENERATOR OPERATION The concept of a freshwater generator is very simple Sea water is evaporated using a heat source, separating pure water from

salt, sediment and other elements Freshwater generators often use the diesel engine jacket as a heat

source, although steam can also be used as a heat source. Because freshwater generators often use existing heat to run, the cost of operation is low.

There are two main elements in a freshwater generator:o One, heat exchanger evaporates the sea water, and another

condenses the fresh water vapor into drinking water. o In the condenser element, the vapor is condensed through cooling,

often simply using cold seawater to cool the outside of the unit.o The freshwater generator should include a feature to monitor the

salinity of the processed water. o If the salinity exceeds a specified level, usually between one and ten

parts per million (ppm), the freshwater generator will automatically return the water to the feed line and put it through the cycle again.

Page 11: B1 Freshwater Generator

Operating principleo The feed water to be distilled is taken from the flow of seawater

coolant from the condenser outlet (1).o It enters the evaporator (10) where it evaporates at

approximately 40° to 60°C as it passes between plates that are heated by the heating medium.

o The evaporating temperature corresponds to a vacuum of 85–95%, maintained by the brine air ejector (not shown).

o The vapours generated pass through a demister, where any drops of seawater entrained are removed and fall due to gravity to the brine sump in the bottom of the generator chamber.

o The clean freshwater vapours continue to the condenser (9), where they condense into freshwater as they pass between the cold plates cooled by the cooling water.

Page 12: B1 Freshwater Generator

1) Seawater feed2) Heating medium in3) Heating out4) Seawater cooling in5) Seawater cooling out6) Freshwater out7) Evaporated steam8) Demister9) Condenser10) Evaporator11) Brine out

Page 13: B1 Freshwater Generator
Page 14: B1 Freshwater Generator

By

ZAKWAN BIN DERAMAN

Page 15: B1 Freshwater Generator

TYPES OF FRESHWATER GENERATORS• Plate Type Freshwater Generator• Tubular Type Freshwater Generator• Reverse Osmosis Freshwater Generator

Page 16: B1 Freshwater Generator

PRO & CONTRA

Page 17: B1 Freshwater Generator

Plate Type Freshwater Generator

Advantage/s•Flexible installation•Easy maintenance•Compatible with variety of heating sources

Disadvantage/s

•High cost for Titanium(Plate)

Page 18: B1 Freshwater Generator

Tubular Type Freshwater Generator

Advantage/s •No fuel consumption•Compact structure•Can be used as cooler

Disadvantage/s

•Lower power consumption when overhearted

Page 19: B1 Freshwater Generator

Reverse Osmosis Freshwater Generator

Advantage/s•Flexible design•Wide range production•Regular chemical dosing

Disadvantage/s

•Maintenance high

Page 20: B1 Freshwater Generator

By

LIM GUOWEI

Page 21: B1 Freshwater Generator

Main parts of fresh water generator

Page 22: B1 Freshwater Generator

1. Evaporator

Page 23: B1 Freshwater Generator

• Main function of evaporator is to raise the sea water temperature by steam or hot water passing outside the tubes.

• When sufficient heat is provided, it will boil and resulting in vapor rising.

Page 24: B1 Freshwater Generator

2. Demister

Page 25: B1 Freshwater Generator

• All the vapor entering the distilling section has to pass through demister

• The demister will letting vapour to pass through freely but any water particles will impinge onto the wire mesh.

Page 26: B1 Freshwater Generator

3. Condenser

Page 27: B1 Freshwater Generator

• Condenser takes sea water as cooling water supply and condensate the hot vapor into water droplet and drop on water catchment’s tray.

Page 28: B1 Freshwater Generator

4. Salinity Detector

Page 29: B1 Freshwater Generator

• Salinometer measures the density of the distillate.

• With an acceptable reading the distillate pump discharges it through a flow controller and a non-return valve to the storage tank.

• If the density is unacceptable, the salinometer provides a signal which stops the pump this pass over the double loop to re-enter the evaporator feed line for re-distillation or pass to bilge.

Page 30: B1 Freshwater Generator

5. Brine Ejector

Page 31: B1 Freshwater Generator

• Water supply is introduced into a nozzle• The pressure drops at the narrow part of the

nozzle inducing a vacuum relative to the atmosphere.

• The vacuum part will pull brine solution and eject it overboard.

Page 32: B1 Freshwater Generator

• Water supply is introduced into a nozzle• The pressure drops at the narrow part of the

nozzle inducing a vacuum relative to the atmosphere.

• The vacuum part will pull brine solution and eject it overboard.

Thank You

Question & Answer