Upload
udriste-daniel
View
215
Download
0
Embed Size (px)
Citation preview
TS REF. : 36827ter
Exclusive property of SILEC CABLE. No copy or diffusion without the written consent of SILEC CABLE. SILEC trademark is a registered trademark.
S U M M A R Y
1. OPTICAL FIBRE CABLES
All dielectric self supported cable for aerial installation Loose tube cables (flat FRP armoured)
24 G652D single mode fibres Particular sheet of the cable
2. PARTICULAR SHEET FOR OPTICAL FIBRE Particular sheet of the optical fibre G 652D
3. IDENTIFICATION
4. DELIVERY CONDITIONS
5. TABLE OF TEST
TS REF. : 36827ter
Exclusive property of SILEC CABLE. No copy or diffusion without the written consent of SILEC CABLE. SILEC trademark is a registered trademark.
1. ALL DIELECTRIC SELF-SUPPORTING OPTICAL FIBRE CABLES
WITH 24 O.F. FOR SPAN UP TO 330 METERS
1. Colour-coded optical fibres (up to 12 OF/tube)
2. Filling compound.
3. Colour-coded thermoplastic tubes (containing up to 12 optical fibres) or fillers (replacing tubes without fibres).
4. Central high-modulus dielectric strength member + optional coating.
5. Longitudinal watertightness (standard: "clean cables" using swellable materials/elements)
6. Binders + optional tape.
7. Aramid yarns
8. PE inner jacket.
9. Rigid dielectric armour constituted of stranded flat GRP elements.
10. Aramid yarns
11. HDPE outer jacket (standard colour: black)./ Optional : anti-tracking
oversheathing. (a)
(a) an additional outer anti-tracking sheath is recommended if the cable is installed near (< 2.0 m) an extra-high voltage conductor
Cable diameter : 18 mm Cable weight : 280 kg/km
TS REF. : 36827ter
Exclusive property of SILEC CABLE. No copy or diffusion without the written consent of SILEC CABLE. SILEC trademark is a registered trademark.
CABLE DATA SHEET
1. ALL DIELECTRIC SELF-SUPPORTING OPTICAL FIBRE CABLE
WITH 24 O.F. FOR SPAN UP TO 330 METERS
CHARACTERISTICS UNIT SPECIFICATION
Fibre-Count 24
CONSTITUTION Cable design 2 watertight tubes containing 12 optical fibres +
4 fillers Central strength member Filling compound Tube dimensions Strength members around the assembly Inner sheath Armouring (strength members) des renforts de tractions
Outer sheath (a) Outer sheath thickness Cable diameter Cable weight
mm
mm mm
kg/km
non metallic (FRP) synthetic 1.6/2.5
Aramid yarns Polyethylene
Stranded flat FRP elements + aramid yarns
HD polyethylene 2.0 18
280
BENDING RADIUS (IEC & EN 60794-1-2 E10 & E11) Minimum bending radius Minimum kinking radius
mm mm
235* 225*
TENSILE PERFORMANCE (IEC & EN 60794-1-2 E1)
Installation in ducts & direct burial
Maximum tensile force during installation (short term) Maximum permanent tensile force
Aerial installation
Tensile force during operation
daN
daN
3400 *
1350*
see next page CRUSH PERFORMANCE (IEC & EN 60794-1-2 E3)
Maximum strain
daN/cm
40*
IMPACT TEST (IEC & EN 60794-1-2 E4)
Energy
N.m
20 (R = 300 mm,3 impacts) (no fibre break)
TEMPERATURE RANGE - Operating/Storage - Installation
-40°C/+70°C ( < 0.1 dB/km @ 1550 nm)*
-5°C/+40°C
WATERTIGHTNESS Compliant to IEC 60794-1-2-F5 (3m/24h)
RODENT RESISTANCE Yes with standard european rats (Rattus Norvegicus and Long Evans Rattus)
SHOT GUN RESISTANCE yes
PACKING Delivery length, m Drum type Drum size Weight of the loaded drum
m
m kg
4100
G export + battens. 1.9 x 1.15
1620
* : reversible after test
(a) an additional outer anti-tracking sheath (thickness ~0.5 mm) is recommended if the cable is installed near (< 1.5 m) an extra-high voltage conductor
TS REF. : 36827ter
Exclusive property of SILEC CABLE. No copy or diffusion without the written consent of SILEC CABLE. SILEC trademark is a registered trademark.
1. ALL DIELECTRIC SELF-SUPPORTING OPTICAL FIBRE CABLE
WITH 24 O.F. FOR SPAN UP TO 330 METERS
24 OF Cable
MAIN CHARACTERISTICS FOR AERIAL INSTALLATION
Cable Young modulus : 1663 daN/mm2
Cable temperature expansion coefficient : 1.20.10-5
/°C
Cable breaking tensile load : 6805daN
Cable elastic limit : 2265daN
CLIMATIC CONDITIONS FOR AERIAL INSTALLATION
Maximum span : 330 m (initial sag @ +15 °C = 2.5 % of span)
Conditions Installation Winter 1 Winter 2 Average Summer 1 Summer 2
Temperature, °C 15 -40 -40 5 35 35
Wind
pressure or
speed
Pa 0 0 ~550 (55
daN/m2)
~550 (55
daN/m2)
0 ~550 (55
daN/m2)
m/s 0 0 28.58 28.58 0 28.6
km/h 0 0 102.89 102.89 0 103
Ice / frost thickness, mm 0 5 0 0 0 0
kg/m 0 0.29 0 0 0 0
Tensile, daN 462 738 1224 1160 439 1122
Sag, m 8.25 9.24 11.44 12.07 8.67 12.48
Maximum span : 330 m (initial sag @ +15 °C = 3.0 % of span)
Conditions Installation Winter 1 Winter 2 Average Summer 1 Summer 2
Temperature, °C 15 -40 -40 5 35 35
Wind
pressure or
speed
Pa 0 0 ~550 (55
daN/m2)
~550 (55
daN/m2)
0 ~550 (55
daN/m2)
m/s 0 0 28.58 28.58 0 28.6
km/h 0 0 102.89 102.89 0 103
Ice / frost thickness, mm 0 5 0 0 0 0
kg/m 0 0.29 0 0 0 0
Tensile, daN 385 732 1117 1064 370 1032
Sag, m 9.90 10.58 12.54 13.17 10.30 13.58
Maximum span : 330 m (initial sag @ +15 °C = 3.5 % of span)
Conditions Installation Winter 1 Winter 2 Average Summer 1 Summer 2
Temperature, °C 15 -40 -40 5 35 35
Wind
pressure or
speed
Pa 0 0 ~550 (55
daN/m2)
~550 (55
daN/m2)
0 ~550 (55
daN/m2)
m/s 0 0 28.58 28.58 0 28.6
km/h 0 0 102.89 102.89 0 103
Ice / frost thickness, mm 0 5 0 0 0 0
kg/m 0 0.29 0 0 0 0
Tensile, daN 330 646 1021 978 320 951
Sag, m 11.55 11.99 13.72 14.32 11.92 14.72
Note:
This cable can be also installed with a sag of 2 % of span (sag = 6.60 m / installation tensile force @
+15 °C = 580 daN).
TS REF. : 36827ter
Exclusive property of SILEC CABLE. No copy or diffusion without the written consent of SILEC CABLE. SILEC trademark is a registered trademark.
2. PARTICULAR SHEET FOR OPTICAL FIBRE
REDUCED-WATER-PEAK SINGLE MODE OPTICAL FIBRE (G652D)
NOMENCLATURE UNIT SPECIFICATION
TECHNOLOGY Coating
EPOXY - ACRYLATE
GEOMETRICAL CHARACTERISTICS
- wavelength
- mode field diameter
- cladding diameter
- coating diameter
- cladding non circularity
- coating/cladding concentricity error
- core/cladding concentricity error
nm
µm
µm
µm
%
µm
µm
1310
9.1 + 0.5
125 + 1
245 + 10
< 1
< 10
< 0.6
TRANSMISSION CHARACTERISTICS
- cabled cut-off wavelength
- attenuation at 1310 nm (1),
at 1383 nm,
at 1550 nm (1),
at 1625 nm
- transmission curve regularity at 1550 nm
- chromatic dispersion between 1285-1330 nm
- chromatic dispersion at 1550 nm
- PMD (value for fibre in cable)
nm
dB/km
dB/km
dB/km
dB/km
dB
ps/nm.km
ps/nm.km
ps/km 1/2
cc < 1260
< 0.36 (1)
< 0.35
< 0.22 (1)
< 0.26
< 0.1
< 3.5
< 18
< 0.2
STANDARD
ITU-T Recommendation
G652 D
(1) : 10 % of the fibres (in cable) presented in reception can have an attenuation :
< 0.38 dB/km at 1310 nm
< 0.23 dB/km at 1550 nm
TS REF. : 36827ter
Exclusive property of SILEC CABLE. No copy or diffusion without the written consent of SILEC CABLE. SILEC trademark is a registered trademark.
3. IDENTIFICATION
1. MARKING. Hot foil marking every meter on cable outer sheath. We propose the following marking
" Week Year number of fibre OF SM G652D SILEC " + metric marking Metric marking will be expressed in meters.
2 .IDENTIFICATION. Colour-coding of tube and fibres in each tube :
Fibre colour code : red, blue, green, yellow, violet, white , orange , grey, brown, black, aquamarine, pink.
Tube colour code red, blue.
3. DRUM IDENTIFICATION The following information are included on a plate or label fixed on the drum:
- Cable description, - Cable code, - Length and weight of drum, - Drum number, - Order number,
- Year of manufacture, - SILEC CABLE
TS REF. : 36827ter
Exclusive property of SILEC CABLE. No copy or diffusion without the written consent of SILEC CABLE. SILEC trademark is a registered trademark.
4. DELIVERY CONDITIONS
1. CABLE LENGTHS.
Standard delivery lengths: L ± 3 % (value of L: refer to cable particular sheet)
Provisions for irregular lengths:
- up to 10% of the total order length (with a minimum of one L length) may be split in two equal L/2
lengths
- up to 10% of the total order length (with a minimum of one length) may be delivered in irregular
lengths
2. SEALING OF ENDS.
Each cable end is sealed with an heat-shrinkable cap.
TS REF. : 36827ter
Exclusive property of SILEC CABLE. No copy or diffusion without the written consent of SILEC CABLE. SILEC trademark is a registered trademark.
1/2
5. TABLE OF TESTS
1 / ROUTINE TESTS
We propose routine tests according to the following table.
Tests Reference
Sampling
SILEC
CABLE
Acceptance
(*)
Dimensional - outer diameter
- thickness of the sheath
- identification
Optical and transmission
- attenuation (1) in the
specified window(s)
- regularity of attenuation
at 1550 nm(SM) or 850
nm(MM)
Mechanical on the outer sheath
- tensile strength
- elongation at break
Environment
- water penetration (2)
IEC 60811-1-1
IEC 60793-1-40-C
back-scattering
Method
IEC 60811-1-
EN 50290-2-24 (PE)
IEC 60794.1.2-F5B
1 cable (a)
"
"
100 %
100 %
1 cable (b)
"
1 cable (c)
1 cable
"
"
10 % of cable
(10 % of OF)
"
1 cable
"
1 cable
(*) Acceptance test program to be agreed between customer and SILEC at the time of ordering.
Nota : (a) : 1 test/design of cable / week
(b) :1 test per period/ type of outer sheath/ manufacture line
Period = 1 month if PE sheath
(c) : 1 test/design of cable /month
(1) attenuation :
Backscattering measurements performed from one cable end (1.55 µm for SM OF / 0.85/1.3 µm for
MM OF) + optical continuity for all fibres.
In case of limit values, the measurement will perform from both ends and the attenuation is the
average of the both values. In case of doubt, the attenuation will be determined by the cut-back
reference method (IEC 60793-1-40-A).
Attenuation value is significant only for cable length 1 km
For cable length < 1km, only the regularity of transmission at 1550 nm (SM) or 850 nm (MM) will be
controlled.
TS REF. : 36827ter
Exclusive property of SILEC CABLE. No copy or diffusion without the written consent of SILEC CABLE. SILEC trademark is a registered trademark.
2/2
5. TABLE OF TESTS
(Following) (2) Water penetration test
Applicable to the whole cable or only to watertight parts, according to cable design and
specifications.
Conditions : sample length : 3 meters; water height: 1 m; duration: 24 hours
2 / TYPE TESTS (not included in cable’s price) :
We perform ISO 9001 certified Quality Assurance system and internal test procedures
ensuring that the cables supplied meet the requirements of customer.
In this framework, type tests are carried out when initially designing/developing the given
cable type, and are not intended to be repeated on every order or manufactured cable length.
However, on customer's request, the renewal of some type tests may be considered as part of the
order acceptance program, providing an agreement has been reached between the customer and
SILEC at the time of ordering, including, if any, the specific conditions applicable to the
implementation of the tests.
Alternatively, certificates of conformity or test reports, relating to previous supplies and/or
qualification programs of same or similar cable type, can be provided as part of the technical
documentation pertaining to the order.
For information, the following table shows the main type tests relevant to the proposed type of
cable and supporting the characteristics stated in the cable particular data sheet.
Reference IEC 60794.1.2-
EN 60794.1.2
- tensile resistance
- crush resistance
- impact resistance
- kink resistance
- bending resistance
- temperature cycling
E1
E3
E4
E10
E11
F1