AXPERT-HIVERTMedium Voltage Drive

AXPERT-HIVERT

TOTAL SOLUTION IN MOTION CONTROL

MEDIUM VOLTAGE DRIVE

AN ISO 9001 : 2008 COMPANY

Page 2: AXPERT-HIVERT€¦ · SPEED5 SPEED4 SPEED3 SPEED2 SPEED1 STOP REV FWD b a C/L3 B/L2 A/L1 HV Ready Run MV OFF U V W B c N n OFF HV S/W CONTROL HEAVY FAULT HEAVY FAULT. 06 High-quality

02

Introduction

AMTECH is one of the leading manufacturers of low voltage AC

Drive with world class manufacturing facility and strong in-house

R&D. Now AMTECH has come up with the state-of-art technology

innovated AXPERT- HIVERT Series Medium Voltage VFD. With the

strong technical support system and global network, Amtech is in

position to provide highest up time in the industry.

Product Structure

Transformer Cabinet

Isolating Transformer:

Transformer Cooling Fan:

Secondary multi-winding output

provides phase-shift power supply to the power unit. This can

greatly improve the current waveform on grid side and reduce

the harmonic interference of the equipment to power grid.

Cooling fan specifically for dry

transformer is configured according to different capacity.

Power Unit Cabinet

Controller:

Power Unit:

I/O Board:

LCD Screen/Keypad:

By-pass Cabinet or Switching Cabinet (Optional)

System Cooling Fan

For space vector PWM control, signal acquisition and processing, communication between units via fibe as for completely

electrical isolation.

Modularized design of power units, interchangeable and easy to produce and repair.

For processing of the digital and analog signals of the system, thus to meet the needs of different applications.

For functions such as parameter setup, control, fault saving and communication. Single-chip microcomputer, full

English display and highly reliable.

The by-pass cabinet or switching cabinet may employ isolating breaker, vacuum contactor or the combination, depending on the user's

working conditions. The function of by-pass cabinet is to put the motor into operation in industry frequency grid after the Inverter exits, so

as to ensure the continuity of user's production. The switching cabinet is designed to divert the inverter output to different motors.

High efficiency fan from world renowned manufacturer, advantaged in large air flow and long service life.

r optics

Cooling fan

Transformer cabinet Power Unit/control cabinet Manual bypass cabinet

11kV cabinet outline drawing (including manual bypass cabinet)

Page 3: AXPERT-HIVERT€¦ · SPEED5 SPEED4 SPEED3 SPEED2 SPEED1 STOP REV FWD b a C/L3 B/L2 A/L1 HV Ready Run MV OFF U V W B c N n OFF HV S/W CONTROL HEAVY FAULT HEAVY FAULT. 06 High-quality

03

1.Topology Structure of Main Circuit

3.3kV Series : ,

4.16kV Series : ,

6.6kV Series : ,

11kV Series : ,

Consisting of 9 power units. Every 3 power units are connected in series to form one phase 3-phase Y-type connection.

Consisting of 12 power units. Every 4 power units are connected in series to form one phase 3-phase Y-type connection.

Consisting of 18 power units. Every 6 power units are connected in series to form one phase 3-phase Y-type connection.

Consisting of 27 power units. Every 9 power units are connected in series to form one phase 3-phase Y-type connection.

Working Principle of Inverter

AXPERT-HIVERT Series Medium Voltage Drive adopts AC-DC-AC direct medium voltage input and

output and employs IGBT based power units in series, obtaining MV by means of overlap wave. In full

application of the proven technology for normal voltage inverter, AXPERT-HIVERT series has very high

reliability.

Main Circuit Diagram of AXPERT- HIVERT Medium Voltage Drive 6.6kV Series

Page 4: AXPERT-HIVERT€¦ · SPEED5 SPEED4 SPEED3 SPEED2 SPEED1 STOP REV FWD b a C/L3 B/L2 A/L1 HV Ready Run MV OFF U V W B c N n OFF HV S/W CONTROL HEAVY FAULT HEAVY FAULT. 06 High-quality

04

2. Voltage Overlap Diagram

Each phase of AXPERT- HIVERT Series Medium Voltage Drive consists of multiple power units connected in series, and each power unit is

isolated by the secondary winding of isolating transformer. By changing the quantity of units in series, the phase-shift power supply can easily

obtain the output of different voltage level, without being subjected to the restriction of the power devices for their voltage resistance

performance. Assuming that each phase of an inverter rated 6.6kV consists of 6 power units and the rated voltage of power unit is 690V. the

phase voltage will be 3810V after connection in series (The corresponding line voltage is 6.6kV). Each phase of 11KV Inverter consists of 9

power units, the rated voltage of power unit is 710V, and the working voltage is 710V.

3. Structural Diagram of Power Unit

AXPERT-HIVERT Series Medium Voltage Drive consists of

multiple power units connected in series, and each power

unit is powered by the secondary isolating winding of the

input isolating transformer. The power unit is of AC-DC-AC

structure, equivalent to a low-voltage power source inverter

of 3-phase input single-phase output. As power units are

fully identical in structure and electrical performance, very

easy for maintenance and replacement.

The power unit receives the signal via optical fiber and adopts space vector sinewave pulse (PWM) to control the conductivity and disconnection

of Q1~Q4 IGBT, outputting single-phase pulse width modulation waveform. Each unit is only possible to have three states of output voltage.

When Q1 and Q4 are connected, the output voltage state of LI and L2 will be 1; when Q2 and Q3 are connected, the output voltage state of L1 and

L2 will be -1; and when Q1 and Q2, or Q3 and Q4 are connected, the output voltage state of L1 and L2 will be 0.

Inverter Series Quantity of Series Unit Rated Voltage Unit Working Voltage Output Phase Voltage Output Line Voltage Number of Voltage

Unto for Each Phase (V) (V) (V) (KV) Level tor Each Phase

3.3kV 3 690 635 1905 3.3 7

4.16kV 4 690 600 2402 4.16 9

6.6kV 6 690 635 3810 6.6 13

11kV 9 710 710 6390 11 19

Fuse Diode Rectifier DC BUS Inverter

R

S

T

L1

L2

Q1 Q2

Q3 Q4

3.3kV Series 11kV Series

3300VLine Voltage

1905VPhase Voltage

635

635

635

635

635

635 635

635

635

710

710

710

710

710

710

710

710

710

710

710

710

710

710

710

710

710

710

11000VLine Voltage

6390VPhase Voltage

710

710

710

710

710

710

710

710

710

6.6kV Series

6600VLine Voltage

3810VPhase Voltage

635

635

635

635

635

635

635

635

635

635 635

635

635

635

635

635

635 635

Page 5: AXPERT-HIVERT€¦ · SPEED5 SPEED4 SPEED3 SPEED2 SPEED1 STOP REV FWD b a C/L3 B/L2 A/L1 HV Ready Run MV OFF U V W B c N n OFF HV S/W CONTROL HEAVY FAULT HEAVY FAULT. 06 High-quality

05

4. External System Diagram

READY

ERROR Minor Fault Alarm

RUN

ON HV

OFF HV

REMOTE

FREQ. MATCH

MV ON Permission

Remote Control Indication

Phase Lock Successful

Fatal Fault Output (NO)

Fatal Fault Output (NC)

AI01

AI03

EGND

AI02

AI04

EGND

3-phase Induction Motor

PE

IM 3~

Output Frequency Analog Current Output

Output Frequency Analog Current Output

Output Frequency Common End

Output Current Analog Current Output

Output Current Analog Current Output

Output Current Common End

3-phase MV Input Main Power

3-phase, 4-wire 415VAC control power

Y

R

A

B

C

Forward start/stop (pulse start)

Reverse start/stop (pulse stop)

Emergency Stop

Speed 1

Speed 2

Speed 3

Speed 4

Speed 5

Remote reset

H. V. Breaking

H. V. Breaking

Line Frequency Switching

Analog Current Set

Analog Current Set

Analog Set Command End

Analog Current Feedback

Analog Current Feedback

Analog Feedback Common End

Communication + Signal

Communication - Signal485-

485+

FGND

AFI

AFI

IGND

AII

AII

DCM

OFF HV

RESET

SPEED5

SPEED4

SPEED3

SPEED2

SPEED1

STOP

REV

FWD

b

a

C/L3

B/L2

A/L1

HV Ready

Run

MV OFF

U

V

W

B c

N n

OFF HV

S/W CONTROL

HEAVY FAULT

HEAVY FAULT

Page 6: AXPERT-HIVERT€¦ · SPEED5 SPEED4 SPEED3 SPEED2 SPEED1 STOP REV FWD b a C/L3 B/L2 A/L1 HV Ready Run MV OFF U V W B c N n OFF HV S/W CONTROL HEAVY FAULT HEAVY FAULT. 06 High-quality

06

High-quality Current Input

Perfect Output Performance

Through phase-shift voltage dropping, the secondary winding of isolating transformer on input side will provide isolated power source to

each power unit. For 3.3kV, it is equivalent to 18-pulse, (24-pulse for 4.16kV, 36-pulse for 6.6kV, 54-pulse for 11kV) un-controlled rectifying

input. This eliminates most of the harmonic current caused by each power unit and greatly inhibit the generation of harmonic wave on grid

side.

The harmonic voltage and THD caused to electric grid by the inverter meets the most stringent requirements for THD as specified in IEEE

Std519-1992 and GB/T14549-93 (Quality of Electric Energy Supply Harmonics in Public Supply Networks). The inverter requires no

installation of filter, but it can protect the surrounding equipment from harmonic interference. The power factor within normal range of speed

regulation is over 0.95, so the power-factor compensation capacitor is not required.

Reduce the reactive input and decrease the supply capacity.

The units are connected in series and of PWM overlap output. Each phase consists of 6 units for 6.6kV series inverter, and 9 units for 11kV series.

This results in greatly reduced output of harmonic content, so that the output waveform is nearly perfect sine wave. In comparison with other

types of high voltage large-capacity drives, AXPERT- HIVERT Series MVD has following advantages:

No output filter required.

Able to drive common high-voltage motor without increasing the motor temperature or decreasing the motor capacity.

Motor cable is free of any length restriction.

Protective insulation of motor is free from the damage of dv/dt stress.

Service life of the equipment will not be shortened due to harmonic torque.

Product Characteristics

AXPERT- HIVERT Series Medium Voltage large-capacity drive is a type of medium voltage AC motor speed regulation drive. Our drive adopts

the advanced technology of series connection and wave overlap of the power unit, space vector sinewave PWM control. It also incorporates full

English operating interface and high-performance IGBT based modules , featuring in high reliability, superior performance and easy operation. It

can be used for a wide range of applications such as regulation, energy saving, soft startup and intelligent control of the fan, water pump,

compressors and other similar loads driven by medium voltage AC motor.

Input Current Waveform Output Voltage Waveform Output Current Waveform

Page 7: AXPERT-HIVERT€¦ · SPEED5 SPEED4 SPEED3 SPEED2 SPEED1 STOP REV FWD b a C/L3 B/L2 A/L1 HV Ready Run MV OFF U V W B c N n OFF HV S/W CONTROL HEAVY FAULT HEAVY FAULT. 06 High-quality

07

User-Friendly Interface

The user interface includes 3 indicators, 2 buttons. 1 LCD and 1 mini keypad. If the red indicator on the

left is bright, it indicates that the inverter main power is on and standby. If the green indicator is bright, it

indicates that the inverter is running. If the red indicator on the right is normally bright, it indicates that inverter

is incurred to fatal faults and shall be disconnected from the main power automatically. If the red indicator on the right

blinks, it indicates light fault, in which case the inverter may run continuously but requiring elimination of the fault.

Below the indicators is an industrial LCD display with 240x128 resolution and a mini keypad, on which 8-line characters

can be displayed. From the LCD display and keypad, you can perform all operations of the inverter.

By pressing PRG key, you can switch between four pages, sequentially as system status page, function setup page,

parameter setup page and fault logging page.

Advantage: No mechanical rotating component, long operating reliability, and easy upgrading of software.

Flexible Control Options

Five Options of Frequency Set

AVR (Automatic Voltage Adjustment) Function

PID Function

nLocal Control: Direct control from the button on cabinet door or

the keypad. This is the main control method.

nRemote I/O Control: Realize remote control by connecting to the

remote switch signal via the I/O board.

nHost Control: Isolated RS-485 port and adoption of standard

MODBUS RTU communication protocol. Able to connect with host

system like DCS for optimized coordination control.

nDirect command from main interface.

nSet by analog signal (4-20mA signal).

nSet by host computer via RS-485 port.

nMulti-speed set, suitable for the working conditions in cyclic change.

nIn event of closed-loop operation, it will be automatic set by built-in PID via computation.

According to output voltage feedback, the inverter can automatically

adjust the output voltage to make it free from the influence caused by

the change of grid voltage and loads, and protect the motor from

insulation damage due to long overvoltage or core overheating due to

high magnetic flux density.

Built-in full digital PID is provided for closed-loop control upon the

users' requirements and for realization of operation under constant

press or constant fluid flux. PID parameters can be adjusted online.

Current Limiting Function

Self-diagnosis Function

Instantaneous Power Loss Tracing Function

Other Characteristics

In event the output current of the inverter exceeds the preset value, the

inverter will automatically limit the current output to avoid overcurrent

protection incurred during acceleration or deceleration or due to

sudden change of the loads, thus to minimize the stop times of the

machine.

AXPERT-HIVERT MVD is provided with complete self-diagnosis

capability to monitor the system status online. In event of any fault, the

inverter will be automatically activated to take protective actions and

save the time, cause and location of the fault. This will help the

maintenance personnel find the cause and eliminate the fault quickly.

In event the electric grid is incurred to instantaneous power loss, the

inverter will control the motor to be under power-generating status and

keep decelerated operation. If the electric grid resumes to normal, the

inverter will immediately return to original operating status. The keeping

time is 10 msec and typical value of the fan load is 3 sec.

nHighly efficient, with the system total efficiency up to 96% or over.

nThe control power is simultaneously supplied by 415VAC.

nWide range of input voltage.

nFast braking function.

nResonance frequency avoidance.

nCustomized design available upon the user's request.

Page 8: AXPERT-HIVERT€¦ · SPEED5 SPEED4 SPEED3 SPEED2 SPEED1 STOP REV FWD b a C/L3 B/L2 A/L1 HV Ready Run MV OFF U V W B c N n OFF HV S/W CONTROL HEAVY FAULT HEAVY FAULT. 06 High-quality

1608

1. One Inverter drives one motor

When the inverter exits the operation, it may switch the motor into the grid via the by-pass loop, thus to ensure the continuity of the production activity. If vacuum contactor is selected for the switch K1, K2 and K3, the switching operation may be completed automatically.

Application Program

2. One inverter switches between two motors

To cut your investment, you may select this method if one inverter needs to switch between two motors, i.e. one in service and one on standby.

MV Busbar

DL

MV Cabinet

K1

K2K3

Optional

By-pass Cabinet

D

AXPERTHIVERT

MV Inverter

MV Busbar

DL

MV Cabinet

K1 K2 By-pass Cabinet

AXPERTHIVERT

MV Inverter

DL1 DL2

D1 D2

Product Parameters

1. Technical Parameters6.6kV Series3.3kV Series 11kV Series

Rated input voltage

Input frequency 50Hz/60Hz (±10%)

Modulation technology Space vector PWM control

Control power 415VAC, 1~5 kVA depending upon the power rating

Input power factor >0.96

Efficiency (including transformer) >96%, under rated load, for VFD

Output frequency range 0Hz~120Hz

Output frequency resolution 0.01Hz

Overload capacity 120% for 2 minute

Analog input 2-channel, 4~20mA / 2

Analog output 4-channel, 4~20mA

Communication with host Isolating RS-485 port, MODBUS RTU protocol, other protocol optional

Accel and Decel time 5s~1600s

Digital Input and output Input : 12 / Output : 13 (All potential free contacts)

Operating environmental temperature 0~ 45ºC, derate above

Storage/transportation temperature -40 ~ 70ºC

Cooling mode Forced air cooling

Environmental humidity 90% or below, no condensation

Installation elevation 1000 m, derate above 1000m, consult Amtech for derating

Protection level IP30, consult Amtech for higher protection

Cabinet colors PANTONE cool gray 1U & 2915U, consult Amtech for customization

3.3kV (-20%,+15%) 4.16kV (-20%,+15%) 6.6kV (-20%,+15%) 11kV (-20%,+15%)

>98%

~10V

45ºC, consult Amtech for derating

4.16kV Series

Page 9: AXPERT-HIVERT€¦ · SPEED5 SPEED4 SPEED3 SPEED2 SPEED1 STOP REV FWD b a C/L3 B/L2 A/L1 HV Ready Run MV OFF U V W B c N n OFF HV S/W CONTROL HEAVY FAULT HEAVY FAULT. 06 High-quality

1609

2. Model and IdentificationAXPERTHIVERT

3. Product Series

Rated output voltage (kV), e.g. 3.3, 4.16, 6.6, 11

Rated output current (A), e.g. 077, 130

-

-

Series VMe Drive

-

4.16 SerieskV

6.6 SerieskV

11 SerieskV

3.3 SerieskV

Page 10: AXPERT-HIVERT€¦ · SPEED5 SPEED4 SPEED3 SPEED2 SPEED1 STOP REV FWD b a C/L3 B/L2 A/L1 HV Ready Run MV OFF U V W B c N n OFF HV S/W CONTROL HEAVY FAULT HEAVY FAULT. 06 High-quality

10

Note :

1. The by-pass cabinet and switching cabinet are optional.

2. Size of manual by-pass cabinet, manual switching cabinet and automatic switching cabinet: 1000 wide, 2100 high in minimum, or as high as the inverter if the inverter is over 2100 high; the depth is the same as the inverter cabinet.

3. Size of the automatic by-pass cabinet: 2*1000 wide, 2100 high in minimum, or as high as the inverter if the inverter is 2100 high or higher the depth is the same as the inverter cabinet.

4. Dimensions & specifications are subject to change without notice.

DA=C

F

E

* Transformer is included in Power Cell Cabinet (Refer Fig.2).

MVD Dimension Details

Fig.1 Cabinet Outline with Seperate Transformer Cabinet Fig.2 Cabinet Outline with Transformer

E

F

D

* In case of Fig.2, total width is equal to Power Cell Cabinet width.

Page 11: AXPERT-HIVERT€¦ · SPEED5 SPEED4 SPEED3 SPEED2 SPEED1 STOP REV FWD b a C/L3 B/L2 A/L1 HV Ready Run MV OFF U V W B c N n OFF HV S/W CONTROL HEAVY FAULT HEAVY FAULT. 06 High-quality

11

Application Industries and Fields

AXPERT-HIVERT Series Medium Voltage Drive is a perfect solution for soft start, speed adjusting,energy saving and intelligent control of high voltage AC motors (including synchronous and asynchronous motors).

Typical application industries include :

l

l l l

l l l

Forced draft fan lurry pump rimary fan ompressor

Water pumping energy storage pump Induced draft fan Coal mill

Secondary fan Condensate pump Powder exhaust fan

l l l S P C

Thermal power, Hydro power, Garbage biomass

l l l

l l l l

l

P W F

Submerged pump Brine pump Compressor Pressure blower

Feed water pump for offshore oil platform

ipeline transportation pump ater injection pump eed water pump

Petroleum, Petrochemical, Natural gas

l l l l

l l l l

l l

D M S C

Feeding pump Stirring pump Kiln transmission Ventilation fan

Drainage pump Medium pump

escaling pump ud pump lurry pump lean water pump

Coal mines & minerals

l l l

l l l l

l l l

B P I

Compressor Kneader Compressing blower Forced draft fan

Secondary dust removal blower Water-delivery pump Descaling pump

Feed water pump

last furnace blower rimary dust removal blower nduced draft fan

Steel & nonferrous metallurgy

l l l

l l l

K K R

Coal mill Dust removal fan Cooling fan

iln draft fan iln fan otary kiln transmission

Cement & building materials

l l l l

l l l l

P I F P

Sewage pump Cleaning water pump Lifting pump Reclaimed water pump

ressure blower nduced draft fan orced draft fan ressure pump

Municipal (heat supply, water supply, sewage etc.)

l l l l

l l

G P C A

Soft water pump Water-delivery pump

as blower ressure pump ompressor xial flow pump

Light industry, chemical industry

l l T West stand ind tunnel

Military industry & others

Page 12: AXPERT-HIVERT€¦ · SPEED5 SPEED4 SPEED3 SPEED2 SPEED1 STOP REV FWD b a C/L3 B/L2 A/L1 HV Ready Run MV OFF U V W B c N n OFF HV S/W CONTROL HEAVY FAULT HEAVY FAULT. 06 High-quality

OUR OTHER OFFERINGS

We provide complete motion control system solutions or individual system components to address industry specific requirements and optimize your process.

Our solutions are simple, compatible and environment friendly, resulting in efficient production, cost optimization a n d m i n i m i z i n g h u m a n intervention. It even leads to energy conservation especially i n t y p i c a l F a n , B l o w e r applications.

AXPERT-EAZY AC Drive

AXPERT-VT240S AC Drive

AXPERT-HIVERT Medium Voltage Drive

AXPERT-OPTI torque Soft Starter

AXPERT-EAZY HF-High Frequency Drive

Fans, Blowers, pumps

Compressors, Centrifuges

Agitators & Conveyors

Oil & Gas

Mining

Flagship Solutions

Applications

l

l

l

l

l

l

l

l

l

l

CA

T.N

O.

: A

EIL

/MV

D/1

1-1

2

“Automation made Easy” is our philosophy to simplify the increasing complexi ty of modern production systems through our AMTECH JETTER PROCESS PLC Technology platform.

We simplify the contradictory imperatives in modern auto-mation to provide simplistic but cost effective customized solutions.

NANO, DELTA, M IKRO, JETWEB, JETVIEW, HMI & SCADA, SERVO & AXES CONTROL SYSTEM

Paper Machine Automation

Textiles Manufacturing

Packaging

Winder Machine

Crane & Material Handling Equipment

CNC Machines

Semiconductor Assembly line

Retrofit solutions

Flagship Solutions

Applications

l

l

l

l

l

l

l

l

Amtech 's Power Qual i ty Solutions offer you the synergy of multiple benefits - energy conse rva t i on , enhanced operational efficiency and reliability through a dedicated r a n g e o f p r o d u c t s a n d services.

Passive Harmonic Filter

Active Harmonic Filter

Harmonic Reactor

Static Harmonic Converter

EMI/RFI Filter

Sinus Filter

Active Front end Converter

Harmonic Audit and Solutions to comply with IEEE-519 standard

System design, optimization & pay-back analysis

Consultancy for Power Quality improvement

Energy Audit and solutions by experienced BEE certified professionals

Products

Services

l

l

l

l

l

l

l

l

l

l

l

l

Training on Power Quality Management

We offer technology solutions to independent R&D labs as well as industrial segments, l ike Traction, Renewable Energy sources (Wind, Solar etc.) thereby zeroing your lead time to commercialization.

Traction Drive

High Voltage Power Supply

Battery back-up drive & systems for critical loads

Wind Power Converter

Solar Inverter

Retrofit Solutions

Customized solutions for industry specific applications

Solution for Oil, Gas & Mining

Power Electronics Technology outsourcing

Products

Services

l

l

l

l

l

l

l

l

l

Specifications in this catalog are subject to change without notice.

MOTION CONTROL AUTOMATION POWER QUALITY INDUSTRIAL ELECTRONICS

“DRIVE FOR SUCCESS”“AUTOMATION.MADE EASY”