TDA - L LONG CASED Construction
Double flanged casing is produced in mild steel or galvanised Steel, the impeller having manually adjustable pitch aerofoil
blades is made of PPG, PAG or Aluminium. Finish Painting or galvanised after manufacture are normal finishes
on all parts. Operating Temperature -20C to +55C
Motors Totally enclosed Class F motor, to a min. IP54 protection are
are fitted as standard. Standard motor up to 2.2kW are usually supplied on DOL starting, motor 3.0kW and above are star/ delta starting.
Airflow Direction
Air flowing from impeller to motor are fitted as standard. Air flowing from motor to impeller can be supplied on request.
Option
Spark resistance construction in accordance to AMCA standard 99-0401-86-type C construction can be supplied upon request.
All Dimension in mm.
MODEL A B C D N Weight ( kg )
Max.Motor* FrameSize
MODEL A B C D N Weight
( kg )Max.Motor*FrameSize
315 315 355 395 355 8 10 8 D71 900 900 945 1000 630 18 12 66 D160M
355 355 395 435 355 8 10 10 D80 1000 1000 1050 1100 630 24 12 73 D160M
400 400 440 480 355 12 10 11 D90S 1120 1120 1185 1250 900 24 12 135 D225M
450 450 490 530 400 12 10 14 D90L 1250 1250 1315 1380 1000 24 12 170 D250M
500 500 540 580 500 12 10 18 D90L 1400 1400 1465 1530 1120 32 14 220 D250M
560 560 605 660 500 12 10 22 D112M 1600 1600 1663 1730 1250 32 14 275 D250M
630 630 675 730 500 12 10 24 D112M 1800 1800 1856 1930 1400 32 14 335 D280M
710 710 755 810 500 18 12 40 D112M 2000 2000 2073 2130 1400 32 14 380 D315M
800 800 845 900 560 18 12 49 D132M 2250 2250 2330 2400 1535 36 18 430 D315M
* Motor frame size beyond this range, please consult KRUGER for details --- Weight without motor and impeller. LEA001.E2 Edition 3
D
AXIAL FLOW FAN - direct driven
N x
A
B
C
Printed on April 2011
*** Shaded portion is the recommended operating range based on the duct velocity consideration (friction loss of 1 Pa/m)
2 POLES - 2800 RPM
4 POLES - 1420 RPM
4 POLES - 1420 RPM
0 1 2 3 4 5 6 7
Hst (Pa)
200
400
600
800
1000
1400
Air Flow (M3/S)
315355
400450
500
560
630
8
1200
0
80
40
120
160
240
200
280
320
0.5 1Air Flow (M3/S)
1.5 2 2.5 3 3.5 54 4.5
630
560
500
450
400
355
315
Hst (Pa)
0Air Flow (M3/S)
Hst (Pa)
15
200
400
600
800
1000
1200
3 6 9 12 18 2421 27 30
1250
1120
1000
900
800710
QUICK SELECTION GUIDE 50 Hz
*** Shaded portion is the recommended operating range based on the duct velocity consideration (friction loss of 1 Pa/m)
6 POLES - 900 RPM
6 POLES - 900 RPM
8 POLES - 720 RPM
4 POLES - 1750 RPM
0
50
500Hst (Pa)
Air Flow (M3/S)70605040302010
450
400
350
300
250
200
150
100
2000
18001600
1400
12501120
1000900
800
200 10
500
100
200
400
300
600
700
900
30 40 50 60 70
Hst (Pa)
Air Flow (M3/S)80 90
2000
18001600
14001250
11201000
800
10
90
60
30
210
180
120
150
240Hst (Pa)
Air Flow (M3/S)2 3 4 5 6 7 8 9 10
900
800
710630
560500
450
6 POLES - 900 RPM
QUICK SELECTION GUIDE 50 Hz
*** Shaded portion is the recommended operating range based on the duct velocity consideration (friction loss of 1 Pa/m)
6 POLES - 1150 RPM
6 POLES - 1150 RPM
0
1200Hst (Pa)
Air Flow (M3/S)
400
2
710800
1000
184 6 8 10 12 14 16
200
400
600
800
1000
450500
560630
900
0
Hst (Pa)
Air Flow (M3/S)1 2 3 4 5 6 7 8
100
150
200
300
350
800
710
630
560
500450 50
250
0
200
10
400
600
800
Hst (Pa)
20 30 40 50 60
1400
1600
12501120
1000
900
1000
4 POLES - 1750 RPM
QUICK SELECTION GUIDE 60 Hz