6
180 Axial fans, medium pressure AXC ELECTRICAL ACCESSORIES REV p. 340 FRQ p. 325 Aerofoil impeller with adjustable pitch angle for maximum efficiency. • Die cast aluminium hub and blades. Long casing, hot dip galvanized steel, to DIN EN ISO 1461. Spun flanges for high rigidity, according to Eurovent 1/2 Terminal box in IP65 mounted at the outside of the casing for easy wiring. Three-phase motors IP55, insulation class F, in accordance with EN 60034-5/IEC 85 and IEC 60034-30. Suitable for operating temperatures of up to 55°C Inspection hole to verify correct direction of rotation • Truly reversible version AXR on request • 60 Hz range available Inspection hole to verify correct direction of rotation. The Systemair AXC range of long cased medium pressure axial fans is available in sizes from 315 up to 2000 mm impeller diameter. The ad- justable pitch angle setting offers a wide performance and maximum flexibility to match precisely individual airflow requirements. This cata- logue gives an overview up to size 1250. Other sizes and configurations are available from our selection software. The AXC axial fans have been performance tested in accordance with DIN ISO 5801, DIN 24163 and AMCA 210-99 on the Systemair fan test rig. The IE2 three phase motors are equipped with PTC thermistors for optimum motor protection. The motor is speed controllable by frequency converter. Zx ø D ø TK øDa øDi L s øDi øDa øTK Z x D L s AXC 315 315 395 355 8x10 375 2,5 AXC 355 355 435 395 8x10 375 2,5 AXC 400 400 480 450 8x12 450 2,5 AXC 450 450 530 500 8x12 500 2,5 AXC 500 500 590 560 12x12 540 3 AXC 560 560 650 620 12x12 500/750 3 AXC 630 630 720 690 12x12 500/750 3 AXC 710 710 800 770 16x12 500/700/800 3 AXC 800 800 890 860 16x12 500/700 3 AXC 900 900 1005 970 16x15 640/850 4 AXC 1000 1000 1105 1070 16x15 640/850 4 AXC 1120 1120 1260 1190 20x15 700/1000 4 AXC 1250 1250 1390 1320 20x15 850/1050 5 Length depending on motor size DIMENSIONS Axial fans IE2 2009/640/EG

Axial fans, medium pressure Systemair AXC Data sheet · Axial Fans AX C Two stage fan. 182 Axial fans, medium pressure 0 1000 2000 3000 4000 5000 6000 300 250 200 150 100 50 0 1,2

  • Upload
    others

  • View
    17

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Axial fans, medium pressure Systemair AXC Data sheet · Axial Fans AX C Two stage fan. 182 Axial fans, medium pressure 0 1000 2000 3000 4000 5000 6000 300 250 200 150 100 50 0 1,2

180

Axial fans, medium pressure

AXc ElEctricAl AccESSoriES

REV p. 340

FRQ p. 325

• Aerofoil impeller with adjustable pitch angle for maximum efficiency.• Die cast aluminium hub and blades.• Long casing, hot dip galvanized steel, to DIN EN ISO 1461.• Spun flanges for high rigidity, according to Eurovent 1/2• Terminal box in IP65 mounted at the outside of the casing for easy

wiring.• Three-phase motors IP55, insulation class F, in accordance with EN

60034-5/IEC 85 and IEC 60034-30.• Suitable for operating temperatures of up to 55°C• Inspection hole to verify correct direction of rotation• Truly reversible version AXR on request• 60 Hz range available• Inspection hole to verify correct direction of rotation.The Systemair AXC range of long cased medium pressure axial fans is available in sizes from 315 up to 2000 mm impeller diameter. The ad-justable pitch angle setting offers a wide performance and maximum flexibility to match precisely individual airflow requirements. This cata-logue gives an overview up to size 1250. Other sizes and configurations are available from our selection software. The AXC axial fans have been performance tested in accordance with DIN ISO 5801, DIN 24163 and AMCA 210-99 on the Systemair fan test rig. The IE2 three phase motors are equipped with PTC thermistors for optimum motor protection. The motor is speed controllable by frequency converter.

Zx ø D

ø TK

øDa

øDi

Ls

øDi øDa øTK Z x D L sAXC 315 315 395 355 8x10 375 2,5AXC 355 355 435 395 8x10 375 2,5AXC 400 400 480 450 8x12 450 2,5AXC 450 450 530 500 8x12 500 2,5AXC 500 500 590 560 12x12 540 3AXC 560 560 650 620 12x12 500/750 3AXC 630 630 720 690 12x12 500/750 3AXC 710 710 800 770 16x12 500/700/800 3AXC 800 800 890 860 16x12 500/700 3AXC 900 900 1005 970 16x15 640/850 4AXC 1000 1000 1105 1070 16x15 640/850 4

AXC 1120 1120 1260 1190 20x15 700/1000 4AXC 1250 1250 1390 1320 20x15 850/1050 5Length depending on motor size

diMEnSionS

Axi

al fa

ns

IE22009/640/EG

Page 2: Axial fans, medium pressure Systemair AXC Data sheet · Axial Fans AX C Two stage fan. 182 Axial fans, medium pressure 0 1000 2000 3000 4000 5000 6000 300 250 200 150 100 50 0 1,2

181

Axial fans, medium pressure

ESD-F p. 388

VEntilAtion AccESSoriES

EV-AXCp. 387

FSD p. 386

GFL-AXC p. 389

LRK(F) p. 385

MFA-AXC p. 386

RSA p. 384

SD p. 385

MP p. 387

SG p. 357

Axial fans

The human ear perceives tones and intensity based on sound pressure levels. To consider this fact frequency weighting curves were established. In technical acoustics the A-weighting is most common. The level values in the diagrams are A-weighted. They correspond to the sound power levels of a fan emitted on pressure side in a duct.

According to EN 25136 = LW4 in dB(A).

The catalogue values can be expected, if the flow condi-tions of the fan correspond to those which are adequate according to standard when installing the fan. When in-adequately installed or operated incorrectly, the fan can produce much more noise than necessary for the venti-lation task. The fan sound level which is emitted into the duct is important for the selection of the right duct silencers.The efficiency of silencers depends on the frequency. A division of the frequency into bands with the width of an octave is sufficient in ventilation technology. The following example shows how to calculate a spec-trum from the total sound power level. Table 1 shows the correction values in the different frequencies of the mid octave band.

ExampleCalculation of an octave band for:Operating point 6000 m³/h at 115 Pa staticFan model: AXC 500-10 50 Hz 1440 rpm

resultThe calculation gives a duct emission level Lw4 of 78 dB(A).LWA oct = LWA4 - Lcorrection

Acoustic data of the AXc series

Mid octave band frequency Hz 63 125 250 500 1k 2k 4k 8k

Lcorrection dB 7 7 6 7 10 14 18 23

Table 1: Correction values dependent on the frequency

Mid octave band frequency Hz 63 125 250 500 1k 2k 4k 8k

Lw oct dB(A) 72 72 73 72 69 65 61 56

Table 2: Level values of the fan in the octave band

0

50

100

150

2000 2000 4000 6000 8000 10000 12000

83 dB(A)82807876

76

76

82 84 dB(A)

10° 15°

20°40°

30°

80

78 80 84 dB(A)

Pd

L W dB(A)

78

83

25°

m³/s1 2 3

35°p

[Pa]

q [m³/h]

s

AXC 500-10 50 Hz 1440 rpm

High efficiency impellersThe AXC die cast aerofoil aluminium im-pellers can be offered with full or frac-tional solidities, maximum efficiencies can be obtained. Different impeller/hub con-figurations allow high pressure drops. AXR impellers are truly reversible.

Sturdy casingAXC/AXR axial fan casings are heavy gauge, hot dip galvanized, with spun flanges for high rigidity. Long cased execu-tion as standard stock range. Also avail-able with short casing and with an acous-tically insulated box.

MotorsThe built-in motors are equipped with PTC thermistors for optimum motor protection. Single or two speed motors. Speed con-trollable by frequency converter.Efficiency class IE2 as per 2009/640/EC guidelines.

Multi stage fansFor higher pressure drops two stage fans are offered. Two fans in series increase the available static pressure drop.

QualitySystemair is ISO 9001 ap-proved. The Systemair quality is regularly moni-tored by TÜV Süd.

WarrantySystemair offers a three year warranty on all AXC fan models. The Systemair war-ranty conditions apply.

Performance curves and technical details for the required fan duties are available from our selection software, which can be downloaded or used online from our homepage: www .systemair. de. You can, of course, also order it directly from our cus-tomer support.

Axial fans AXc

two stage fan

Page 3: Axial fans, medium pressure Systemair AXC Data sheet · Axial Fans AX C Two stage fan. 182 Axial fans, medium pressure 0 1000 2000 3000 4000 5000 6000 300 250 200 150 100 50 0 1,2

182

Axial fans, medium pressure

0 1000 2000 3000 4000 5000 6000300

250

200

150

100

50

0

1,21,00,80,60,40,2

0

P [k

W]

AXC 315-10 2-pole

1

0 1000 2000 3000 4000 5000 6000 7000 8000 9000

600

700

500

400

300

200

100

0

1,6

1,20,8

0,4

0

P [k

W]

AXC 355-10 2-pole

1 2

2000 6000 10000 14000 18000

600

700

500

400

300

200

100

0

6,0

4,0

2,0

0

P [k

W]

1 2 3 4 5

AXC 450-10 2-pole

0 2000 4000 6000 8000 10000 12000 14000

600

700

500

400

300

200

100

0

4,0

3,0

2,0

1,0

0

P [k

W]

AXC 400-10 2-pole

1 2 3

Axi

al fa

ns

Item no ModelCAX3152001 AXC 315-10-2 (0.75 kW)CAX3152002 AXC 315-10-2 (1.1 kW)

CAX3152003 AXC 315-10-2 (1.5 kW)

Item no Model

CAX4002001 AXC 400-10-2 (0.75 kW)CAX4002002 AXC 400-10-2 (1.1 kW)CAX4002003 AXC 400-10-2 (1.5 kW)CAX4002004 AXC 400-10-2 (2.2 kW)CAX4002005 AXC 400-10-2 (3.0 kW)

Item no ModelCAX4502001 AXC 450-10-2 (1.1 kW)CAX4502002 AXC 450-10-2 (1.5 kW)CAX4502003 AXC 450-10-2 (2.2 kW)CAX4502004 AXC 450-10-2 (3.0 kW)CAX4502005 AXC 450-10-2 (4.0 kW)

Item no Model

CAX3552001 AXC 355-10-2 (0.75 kW)CAX3552002 AXC 355-10-2 (1.1 kW)CAX3552003 AXC 355-10-2 (1.5 kW)CAX3552004 AXC 355-10-2 (2.2 kW)

Page 4: Axial fans, medium pressure Systemair AXC Data sheet · Axial Fans AX C Two stage fan. 182 Axial fans, medium pressure 0 1000 2000 3000 4000 5000 6000 300 250 200 150 100 50 0 1,2

183

Axial fans, medium pressure

0 5000 10000 15000 20000 25000 30000

600

700

800

900

500

400

300

200

100

0

10,0

5,0

0

P [k

W]

1 2 3 4 5 6 7 8

AXC 500-10 2-pole

5000 10000 15000 20000 25000 30000

600

700

800

900

1000

500

400

300

200

100

0

12,0

4,0

8,0

0P

[kW

]

2 3 4 5 6 7 8

AXC 560-9 2-pole

4000 8000 12000 16000 20000

150

200

250

300

100

50

0

1,52,02,5

0,51,0

0

P [k

W]

2 3 4 5 6

AXC 630-9 4-pole

10000 20000 30000 40000

600

800

1000

1200

1400

400

200

0

12,016,020,0

4,08,0

0

P [k

W]

5 10

AXC 630-9 2-pole

Axial fans

Item no Model

CAX5002001 AXC 500-10-2 (1.1 kW)CAX5002002 AXC 500-10-2 (1.5 kW)CAX5002003 AXC 500-10-2 (2.2 kW)CAX5002004 AXC 500-10-2 (3.0 kW)CAX5002005 AXC 500-10-2 (4.0 kW)

Item no Model

CAX6302017 AXC 630-9-2 (2.2 kW)CAX6302018 AXC 630-9-2 (3 kW)CAX6302019 AXC 630-9-2 (4 kW)CAX6302020 AXC 630-9-2 (5.5 kW)CAX6302021 AXC 630-9-2 (7.5 kW)CAX6302022 AXC 630-9-2 (11 kW)CAX6302023 AXC 630-9-2 (15 kW)CAX6302024 AXC 630-9-2 (18.5 kW)

Item no Model

CAX5602019 AXC 560-9-2 (1.1 kW)CAX5602020 AXC 560-9-2 (1.5 kW)CAX5602021 AXC 560-9-2 (2.2 kW)CAX5602022 AXC 560-9-2 (3.0 kW)CAX5602023 AXC 560-9-2 (4.0 kW)CAX5602024 AXC 560-9-2 (5.5 kW)CAX5602025 AXC 560-9-2 (7.5 kW)CAX5602026 AXC 560-9-2 (11 kW)CAX5602027 AXC 560-9-2 (15 kW)

Item no Model

CAX6304005 AXC 630-9-4 (2.2 kW)

CAX6304006 AXC 630-9-4 (3 kW)

Page 5: Axial fans, medium pressure Systemair AXC Data sheet · Axial Fans AX C Two stage fan. 182 Axial fans, medium pressure 0 1000 2000 3000 4000 5000 6000 300 250 200 150 100 50 0 1,2

184

Axial fans, medium pressure

0 5000 10000 15000 20000 25000 30000

150

200

250

300

350

400

450

100

50

0

3,04,05,0

1,02,0

0

P [k

W]

1 2 3 4 5 6 7 8

AXC 710-9 4-pole

10000 20000 30000 40000

200

300

400

500

600

100

0

6,0

9,0

3,0

0

P [k

W]

5 10

AXC 800-9 4-pole

20000 40000 60000 80000

200

300

400

500

600

700

800

900

100

0

20,0

30,0

10,0

0

P [k

W]

5 10

AXC 1000-10 4-pole

5000 15000 25000 35000 45000 55000 65000

200

300

400

500

600

700

100

0

8,0

12,0

16,0

4,0

0

P [k

W]

5 10 15

AXC 900-10 4-pole

Axi

al fa

ns

Item no Model

CAX9004008 AXC 900-10-4 (2.2 kW)CAX9004009 AXC 900-10-4 (3 kW)CAX9004010 AXC 900-10-4 (4 kW)CAX9004011 AXC 900-10-4 (5.5 kW)CAX9004012 AXC 900-10-4 (7.5 kW)CAX9004013 AXC 900-10-4 (11 kW)CAX9004014 AXC 900-10-4 (15 kW)

Item no Model

CAX7104007 AXC 710-9-4 (2.2 kW)CAX7104008 AXC 710-9-4 (3 kW)CAX7104008 AXC 710-9-4 (4 kW)CAX7104012 AXC 710-9-4 (5.5 kW)

Item no ModelCAX10004007 AXC 1000-10-4 (4 kW)CAX10004008 AXC 1000-10-4 (5.5 kW)CAX1000409 AXC 1000-10-4 (7.7 kW)CAX10004010 AXC 1000-10-4 (11 kW)CAX10004011 AXC 1000-10-4 (15 kW)CAX10004012 AXC 1000-10-4 (18.5 kW)CAX10004013 AXC 1000-10-4 (22 kW)CAX10004014 AXC 1000-10-4 (30 kW)

Item no Model

CAX8004011 AXC 800-9-4 (2.2 kW)CAX8004012 AXC 800-9-4 (3 kW)CAX8004013 AXC 800-9-4 (4 kW)CAX8004014 AXC 800-9-4 (5.5 kW)CAX8004015 AXC 800-9-4 (7.5 kW)

Page 6: Axial fans, medium pressure Systemair AXC Data sheet · Axial Fans AX C Two stage fan. 182 Axial fans, medium pressure 0 1000 2000 3000 4000 5000 6000 300 250 200 150 100 50 0 1,2

185

Axial fans, medium pressure

20000 60000 10000 14000 180000

400

600

800

1000

1200

1400

200

0

40,0

60,0

80,0

20,0

0

P [k

W]

10 20 30 40 50

AXC 1250-12 4-pole

Axial fans

Item no Model

CAX11204006 AXC 1120-10-4 (5.5 kW)CAX11204007 AXC 1120-10-4 (7.5 kW)CAX11204008 AXC 1120-10-4 (11 kW)CAX11204009 AXC 1120-10-4 (15 kW)CAX11204010 AXC 1120-10-4 (18.5 kW)

Item no Model

CAX12504007 AXC 1250-12-4 (11 kW)CAX12504008 AXC 1250-12-4 (15 kW)CAX12504009 AXC 1250-12-4 (18.5 kW)CAX12504010 AXC 1250-12-4 (22 kW)CAX12504011 AXC 1250-12-4 (30 kW)CAX12504012 AXC 1250-12-4 (37 kW)CAX12504013 AXC 1250-12-4 (45 kW)CAX12504014 AXC 1250-12-4 (55 kW)

1000

900

800

700

600

500

400

300

200

100

0

20000 40000 60000 80000 100000 120000 140000

0102030405060

10 20 30

P [k

W]

AXC 1120-10 4-pole

8

12

1620

2428 32 36

8 1216

2024 28

32

36