1 If you want to connect an AX100-Series Fibre Channel storage system - AX100SC or AX100 - through one or two switches to a Novell NetWare ® server, this document is for you. You can use the procedures in this document to install configurations with a new or existing storage system that you want to connect to a new or existing server. The main topics are AX100 Support Website ........................................................................ 2 Terminology ........................................................................................... 3 Before You Start ..................................................................................... 4 Installing HBAs in the Server .............................................................. 7 Installing or Updating the HBA Driver ............................................. 9 Installing PowerPath on the Server .................................................. 11 Installing the Navisphere Server Utility .......................................... 14 Installing the UPS (AX100 Only) ....................................................... 16 Unpacking the Storage System.......................................................... 17 Installing the Storage System............................................................. 19 Installing Additional Disks ................................................................ 23 Installing the Switches in the Cabinet .............................................. 30 Connecting ac Power to an AX100SC Storage System................... 33 Connecting ac Power to an AX100 Storage System........................ 37 Connecting the Storage-System and Switch Management Ports .42 Initializing the Storage System .......................................................... 45 Connecting Switches to the Storage System and Server................ 56 AX100-Series Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server Revision A06 July 25, 2005

AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

  • Upload
    others

  • View
    26

  • Download
    1

Embed Size (px)

Citation preview

Page 1: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

If you want to connect an AX100-Series Fibre Channel storage system - AX100SC or AX100 - through one or two switches to a Novell NetWare® server, this document is for you. You can use the procedures in this document to install configurations with a new or existing storage system that you want to connect to a new or existing server.

The main topics are

◆ AX100 Support Website........................................................................2◆ Terminology ...........................................................................................3◆ Before You Start .....................................................................................4◆ Installing HBAs in the Server ..............................................................7◆ Installing or Updating the HBA Driver .............................................9◆ Installing PowerPath on the Server .................................................. 11◆ Installing the Navisphere Server Utility ..........................................14◆ Installing the UPS (AX100 Only).......................................................16◆ Unpacking the Storage System..........................................................17◆ Installing the Storage System.............................................................19◆ Installing Additional Disks ................................................................23◆ Installing the Switches in the Cabinet ..............................................30◆ Connecting ac Power to an AX100SC Storage System...................33◆ Connecting ac Power to an AX100 Storage System........................37◆ Connecting the Storage-System and Switch Management Ports .42◆ Initializing the Storage System..........................................................45◆ Connecting Switches to the Storage System and Server................56

AX100-Series

Installing a Fibre Channel StorageSystem with a Switch Connection to a

NetWare Server

Revision A06

July 25, 2005

1

Page 2: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

2

AX100 Support Website

◆ Registering the Server with the Storage System ............................ 59◆ Configuring a New Storage System................................................. 62◆ Configuring an Existing Storage System......................................... 66◆ Preparing Virtual Disks to Receive Data ......................................... 69◆ Sending NetWare Disk Information to the Storage System.......... 73◆ Verifying Your Configuration ........................................................... 74

AX100 Support WebsiteThe AX100 support website contains the storage-system release notes and the most recent versions of documents and of the interactive troubleshooting trees. For information on accessing the AX100 support website, refer to the support information that shipped with your storage system.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 3: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Terminology

TerminologyThis document uses the terms new and existing to refer to storage systems, servers, and host bus adapters (HBAs) as follows:

The document also uses SP to refer to a storage processor in the storage system. An AX100SC storage system has only one SP, so it is called a single-SP storage system. An AX100 storage system has two SPs, so it is called a dual-SP storage system.

Existing HBA The host bus adapter (HBA) that is already installed in a server.

Existing server The server that is already configured for and connected to an AX-Series storage system.

Existing storage system An AX-Series storage system that is already connected to a server and configured for storage.

Host A computer that is or will be connected to an AX-Series storage system. This computer is called either a management host or a server, depending on how it is or will be connected to the storage system.

Management host A host from which you manage AX-Series storage systems. It must be on the same LAN as the storage-system management ports. A management host may also be server.

New HBA The HBA that was not already installed in the server.

New server A server that is not already connected to or set up for an AX-Series storage system.

New storage system A storage system that is not connected to a server or configured for storage. It is just as it was shipped to you.

Server A host that is already or will be connected through a switch to the Fibre channel ports on a AX-Series storage systems. A server can also be a management host.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3

Page 4: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

4

Before You Start

Before You StartBefore you start the installation procedure

❑ Review the Supported Configurations in the "Technical descriptions" section on the AX100 website to confirm that the following are supported:

❑ The server hardware that will access the storage system

❑ The operating system version running on the server hardware.

❑ Read the AX100 Release Notes, which are in the "Release Notes" section on the AX100 support website.

❑ Complete the configuration planning worksheets in Planning Your AX100-Series Fibre Channel Storage-System Configuration. This guide is in the "Plan" section on the AX100 support website and on the AX100-Series Documentation CD.

For a new storage system installation, you need

❑ An AX100SC or AX100 storage system and the power cord(s), rails, and CDs that ship with it.

❑ For an AX100 storage system (dual-SP system), an uninterruptible power supply (UPS) kit, including the power cords, UPS sense (serial) cable, and mounting hardware.

❑ Standard ac power for each power supply in the storage system from an independent ac source or a cabinet/rack power distribution unit.

❑ The storage-system serial number located on a label on the back of the chassis (see below).

HW S/N XXX 000NNNNNNNN

EMC3030

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 5: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Before You Start

❑ The following management port network information, which the person responsible for your network should provide:

❑ Static IP address for each SP in the storage system.

❑ Subnet mask for the LAN to which you will connect the storage system.

❑ Default gateway for the LAN to which you will connect the storage system.

For any installation, you need

❑ A management host on the network to which you will connect the storage-system management ports and with a supported Internet browser for running Navisphere® Express. This host can also be the server. For supported hosts and browsers, refer to Supported Configurations in the "Technical descriptions" section on the AX100 support website.

❑ A NetWare® host that is or will be a server with Fibre Channel connections to the storage system. This server must have all required updates, such as hot fixes or patches, installed. For supported hosts and required updates, refer to Supported Configurations in the "Technical descriptions" section on the AX100 support website.

❑ One or more supported QLogic Fibre Channel host bus adapters (HBAs), which may already be installed in the server. These adapters must have the latest supported BIOS and driver. For information on supported HBAs, BIOS, and drivers, refer to Supported Configurations in the "Technical descriptions" section on the AX100 support website.

Never mix Fibre Channel HBAs from different vendors in the same server.

❑ One or two customer-installable switches, which may already be installed for an existing storage system or server. (For information on customer-installable switches, refer to Supported Configurations in the "Technical descriptions" section on the AX100 support website.)

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 5

Page 6: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

6

Before You Start

❑ The following cables, which may already be connected for a configuration with an existing storage system, server, or switches:

❑ A CAT 5 or higher LAN cable for each SP and for each switch if you want to use the switch management software.

❑ An optical cable for each storage-processor (SP) Fibre Channel port you will use on the storage system and for each HBA you will use in the server. (Each storage processor has two ports.) For cable specifications, refer to Technical Specifications in the "Technical description" section on the AX100 support website.

❑ A method for writing data to a virtual disk on the storage system to test the path from a new HBA to the storage system. You can download an I/O simulator (Iometer) from the following website: http://www.iometer.org/.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 7: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Installing HBAs in the Server

Installing HBAs in the ServerFor the server to communicate with the storage system through the Fibre Channel ports, the server must have one or more supported Fibre Channel host bus adapters (HBAs). If the HBAs are already installed, go to Installing or Updating the HBA Driver (page 9). Read this section for all other configurations.

Before You Start

To complete this procedure, you need one or more supported QLogic Fibre Channel HBAs with the latest supported BIOS and driver. For information on supported HBAs, BIOS, and drivers, refer to Supported Configurations in the "Technical descriptions" section on the AX100 support website. Never mix Fibre Channel HBAs from different vendors in the same server.

Install HBAs

CAUTION!HBAs are very susceptible to damage caused by static discharge and need to be handled accordingly. Before handling HBAs, observe the following precautions:

• Store HBAs in anti-static bags.

• Use a ground (ESD) strap whenever you handle HBAs.

• Never plug or unplug HBAs with the power on. Severe component damage can result.

1. If the server is running, shut it down as follows:

a. Shut down the server’s operating system.

b. Power down the server.

c. Unplug the server power cord from the power outlet.

2. Remove the outer covers from the server so that you can access the PCI bus slots.

For information on how to remove the covers from the server, refer to the installation documentation supplied with the server.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 7

Page 8: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

8

Installing HBAs in the Server

3. Put on an ESD wristband, and clip its lead to bare metal on the server’s chassis.

4. For the HBA you are adding, do the following:

a. If the server has a removable PCI card cage, remove it.

b. Locate an empty PCI bus slot.

c. Remove the filler panel from the slot and save it.

d. If your server has a low profile, replace the mounting bracket on the HBA bracket with the low-profile mounting bracket provided with your HBA.

e. Carefully align the HBA with the slot, and then firmly and evenly press the HBA into the slot.

f. Secure the HBA to the slot with the screw or clip from the filler panel.

g. If you have another HBA to install, repeat steps b through f.

h. If you removed a PCI card cage, replace it.

5. Replace the covers you removed from the server.

6. Remove the ESD wristband.

7. Plug the server power cord into the power outlet.

8. Power up the server.

You have completed the installation of the HBA.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 9: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Installing or Updating the HBA Driver

Installing or Updating the HBA DriverThe server must run a supported HBA driver. For information on the supported HBA drivers, refer to Supported Configurations in the "Technical descriptions" section on the AX100 support website.

If the server is already running a supported HBA driver, go to Installing PowerPath on the Server (page 11).

Read this section for all other configurations.

Before You Start To complete this procedure, you need

❑ The latest version of a supported HBA driver. You can download the latest supported version and instructions for installing it from the HBA vendor’s website.

QLogic HBA websitehttp://www.qlogic.com/go/emc_approved

The HBA driver is also on the installation CD that ships with the HBA. This version may not be the latest supported version.

❑ Any updates, such as hot fixes or patches, to the server’s operating system that are required for the HBA driver version you will install.

For information on any required updates, refer to one of the following:

• Supported Configurations in the "Technical descriptions" section on the AX100 support website

• The HBA vendor’s website (see above)

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 9

Page 10: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

10

Installing or Updating the HBA Driver

Install or Update the HBA Driver1. Install any updates, such as hot fixes or patches, to the server’s

operating system that are required for the HBA driver version you are installing.

2. After installing any updates, reboot the server.

3. Install the driver following the instructions on the HBA vendor’s website.

4. Reboot the server when the installation program prompts you to reboot.

Some driver updates may require you to reboot the server.

5. If the installation program did not prompt you to reboot, reboot the server when the driver installation is complete.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 11: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Installing PowerPath on the Server

Installing PowerPath on the ServerFor all configurations you must install PowerPath® on each server that you will connect to the storage system. PowerPath manages the data paths between the server and storage system.

If PowerPath is already running on the server, do one of the following:

◆ For a new AX100SC (single-SP) storage system, go to Unpacking the Storage System (page 17).

◆ For a new AX100 (dual-SP) storage system, go to Installing the UPS (AX100 Only) (page 16).

◆ For an existing storage system (that is, one already connected to another server), go to Connecting Switches to the Storage System and Server (page 56).

Before You StartTo complete this procedure, you need to

❑ Locate the PowerPath for NetWare CD that shipped with the storage system.

Install PowerPath on the Server1. Insert the PowerPath installation CD in the CD drive.

2. At the console prompt, type cdrom and press Enter to mount the CD.

3. Make sure the SCSISAN.CDM module is not installed:

a. At the console prompt, type

NWCONFIG

b. At the Configuration Options main menu, select NCF Files Options.

c. Select Edit STARTUP.NCF File

d. When the system prompts you to specify the server boot path, press Enter.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 11

Page 12: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

12

Installing PowerPath on the Server

e. If SCSISAN.CDM is listed, comment it out.

f. Press F10 to return to the Configurations Options main menu.

4. At the Configuration Options main menu, select Product Options and press Enter.

5. At the Other Installation Actions window, select Install a not listed and press Enter.

A Previously Specified Paths window opens. If you have previously installed PowerPath 3.0.x, this window lists the CD path, which is one of the following:

• EMC_PP_300:\Netware — PowerPath 3.0.0 (Enterprise or Enterprise Plus)

• EMC_PP_302:\Netware — PowerPath 3.0.2 (Base)

• EMC_PP_303:\Netware — PowerPath 3.0.3

• EMC_PP_305:\Netware — PowerPath 3.0.5

6. If EMC_PP_305:\NetWare is listed in the Previously Specified Paths window, select it; otherwise, select any path, and press Enter.

When the system prompts you to install software from the selected path or specify a different one:

• If you selected EMC_PP_305:\NetWare in the previous step, press Enter to install from that path.

• If you did not select EMC_PP_305:\NetWare in the previous step, press F3 and when prompted to specify a directory path, enter

emc_pp_305:\netware

7. At the PowerPath Installation Script menu, select Install/Upgrade PowerPath Driver.

The installation script copies the driver to the system and then opens the EMC PowerPath Registration Utility screen.

8. At the prompt Do you have a new registration key or keys to enter?[n], type n and press Enter.

You see this message: License registration is NOT required to manage the

CLARiiON AX series array.

The system prompts you for the type of reboot.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 13: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Installing PowerPath on the Server

9. Select Shut Down to shut down and power off the server.

10. Power up the server.

CAUTION!If you use the server -ns command to bring up NetWare, you must either load the PowerPath driver manually or remove all redundant paths. Failure to do so may result in virtual disk corruption.

Install a PowerPath PatchCheck the PowerPath information on the "Register to download software" section on the AX100 support website for a patch to the version of PowerPath that you just installed. If such a patch is available, install it, as described in the readme file that accompanies the patch.

What Next? For information on using PowerPath, refer to PowerPath in Action in the "Technical descriptions" section on the AX100 support website or the AX100-Series Documentation CD.

If you are connecting the server to a new AX100SC (single-SP) storage system, go to Unpacking the Storage System (page 17).

If you are connecting the server to a new AX100 (dual-SP) storage system, go to Installing the UPS (AX100 Only) (page 16).

If you are connecting a server to an existing storage system (that is, one already connected to another server), go to Connecting Switches to the Storage System and Server (page 56).

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 13

Page 14: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

14

Installing the Navisphere Server Utility

Installing the Navisphere Server UtilityRead this section for all configurations.

You must run the Navisphere Server Utility on each server connected to the storage system to register the server’s HBAs with the storage system. We recommend that you install it on each server also. If your AX-Series Server Support CD is version 1.1 or higher, you must install it if you want the server to access snapshots (copies of virtual disks) on the storage system.

Before You Start

To complete this procedure, you need the AX-Series Server Support CD that shipped with the storage system.

Install the Server Utility

1. Insert the AX-Series Server Support CD into the server’s CD drive, if it is not already inserted.

2. At a NetWare console, log in as a user with administrative privileges.

3. If DNS is functioning, verify that the IP addresses and names of your DNS servers are registered in the SYS:\ETC\RESOLV.CFG file.

If they are not registered, edit RESOLV.CFG to add the information.

4. On the NetWare server, verify that the SYS:\ETC\HOSTS contains an entry for the server itself, even if you will use DNS.

For example, if the IP address is 10.0.0.1 and the server name is server1, add 10.0.0.1 server1 to the NetWare server’s SYS:\ETC\HOSTS file. The host entry server1 identifies the host and will appear as the visible entry when you assign virtual disks to the server.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 15: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Installing the Navisphere Server Utility

5. Install the Navisphere Server Utility as follows:

a. From the NetWare client command prompt, change the directory to /NETWARE/NAVIHOST directory on the drive containing the CD.

For example:

cd D: /NETWARE/NAVIHOST

b. From the NetWare client command prompt, enter

INSTALL drive

where drive is the remote drive corresponding to the SYS volume on the NetWare server.

For example, INSTALL H: would cause the installation script to create the H:\EMC\NAVIHOST directory with all the required Navisphere Server Utility subdirectories.

6. Set the utility to restart automatically each time the server reboots:

a. On the NetWare server, enter

NWCONFIG

b. From the Installation Options menu, follow the path

NCF files options > Available NCF Files Options > Edit AUTOEXEC.NCF file

c. Add the following command to the end of the AUTOEXEC.NCF file:

LOAD SYS:\EMC\NAVIHOST\AXNAVHST UPDATE

d. Press ESC.

e. At the prompt to save the AUTOEXEC.NCF files, click Yes and press ESC twice.

f. At the prompt to exit the install process, click Yes.

7. Remove the CD from the CD drive.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 15

Page 16: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

16

Installing the UPS (AX100 Only)

Installing the UPS (AX100 Only)Read this section if you are installing a new AX100 (dual-SP) storage system.

You install the storage system and the uninterruptible power supply (UPS) in a 19-inch NEMA-standard cabinet/rack. The UPS is for dual-SP storage systems only.

Before You Start

To complete this procedure, you need a UPS and the cables and the mounting kit that shipped with it.

Install a UPS in a Cabinet

1. Unpack the UPS and save the packaging.

2. Install the UPS in the cabinet, as described in the documentation provided with the UPS.

CAUTION!The UPS ships with the battery cable disconnected. Be sure to connect this cable firmly when you install the UPS. If this cable is not securely connected, the Replace Battery light turns on.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 17: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Unpacking the Storage System

Unpacking the Storage SystemRead this section if you are installing a new storage system.

1. Unpack the storage system as shown on the shipping carton.

CAUTION!The disks in slots marked 0-2 (AX100SC, single-SP storage system) and 0-3 (AX100, dual-SP system) are preloaded with storage-system software according to their slot assignment before shipment. Do not move a preloaded disk from its assigned slot to another slot. Doing so causes the storage system to function improperly. Remove a preloaded disk only to replace it.

Figure 1 Location of Disks 0-3

2. Locate and record the serial number of the storage system (Figure 2).

You need this number later when you initialize the storage system.

EMC2794a

0 1 2 3

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 17

Page 18: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

18

Unpacking the Storage System

Figure 2 Serial Number Location

HW S/N XXX 000NNNNNNNN

EMC3030

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 19: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Installing the Storage System

Installing the Storage SystemRead this section if you are installing a new storage system.

You install the storage system in a 19-inch NEMA-standard cabinet/rack.

Before You Start

To complete this procedure, you need the mounting hardware that shipped with the storage system.

Install the Storage System in a Cabinet

1. Refer to Figure 3 as you install each rail in the cabinet:

a. From the front of the cabinet, insert the alignment pins in the rear channel of the cabinet. Note that the pins insert in the 1/2-inch space between channel holes (marked by a — slash mark in some cabinets).

b. Pull the adjustable rail forward, and attach it with two screws to the inside of the front channel in the two center holes.

c. From the rear of the cabinet, secure each rail to the rear channel. Leave the screws slightly loose to allow for adjustment after the storage system is loaded on the rails.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 19

Page 20: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

20

Installing the Storage System

Figure 3 Installing Storage-System Mounting Rails in a 19-inch NEMA Cabinet

2. If the plastic front bezel is attached, remove it.

3. Remove the four screws that are secured with washers and nuts to black plastic latch brackets and discard the washers and nuts (Figure 4).

Figure 4 Removing the Latch Bracket Screws, Washers, and Nuts

Alignment Pins

EMC2829

Adjustable Rail

Right Front

Right Rear

Screw (2)

Mounting Rail

Screw (2)

Alignment Pin (2)

Mounting Rail

EMC3035

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 21: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Installing the Storage System

WARNING

The equipment is heavy and should be installed into a rack by two people. To avoid personal injury and/or damage to the equipment, do not attempt to lift and install the unit into a rack without a mechanical lift and/or help from another person.

4. From the front of the cabinet, slide the storage system onto the rails so that the cutouts in the rear of the chassis fit into the tabs on the back of each rail (Figure 5).

If the chassis does not slide all the way into the cabinet, you may need to further loosen the screws that hold the rear of the rails in place, then adjust the rail to allow the tabs to fit into the cutouts.

Figure 5 Sliding the Chassis into the Cabinet

EMC2799

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 21

Page 22: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

22

Installing the Storage System

5. Use the four latch bracket screws to secure the storage system and latch brackets to each front channel (Figure 6).

6. Snap the front bezel onto the storage system (Figure 6).

Figure 6 Securing the Chassis and Installing the Front Bezel

What Next? If you have additional disks to install, continue to the next section, Installing Additional Disks (page 23).

If you do not have additional disks to install, go to Installing the Switches in the Cabinet (page 30).

EMC2935

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 23: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Installing Additional Disks

Installing Additional DisksRead this section if you received any disks that are not already installed in the storage system.

Handling FRUs

This section describes the precautions that you must take and the general procedures you must follow when removing, installing, and storing disk drive modules or any other Field Replaceable Unit (FRU).

Power Issues and FRUsThe storage system is designed to be powered up continually and hot repairable. Front bezels should be attached and each compartment should contain a FRU or filler panel to ensure EMI compliance and proper air flow over the FRUs.

You should not remove a faulty FRU until you have a replacement available.

When you replace or install FRUs, you can inadvertently damage the sensitive electronic circuits in the equipment by simply touching them. Electrostatic charge that has accumulated on your body discharges through the circuits. If the air in the work area is very dry, running a humidifier in the work area will help decrease the risk of ESD damage. Follow the procedures below to prevent damage to the equipment.

Read and understand the following instructions:

◆ Provide enough room to work on the equipment. Clear the work site of any unnecessary materials or materials that naturally build up electrostatic charge, such as foam packaging, foam cups, cellophane wrappers, and similar items.

◆ Do not remove replacement or upgrade FRUs from their antistatic packaging until you are ready to install them.

◆ Before you service a storage system, gather together the ESD kit and all other materials you will need. Once servicing begins, avoid moving away from the work site; otherwise, you may build up an electrostatic charge.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 23

Page 24: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

24

Installing Additional Disks

◆ An ESD wristband is supplied with your storage system. To use it, attach the clip of the ESD wristband (strap) to any bare (unpainted) metal on the storage system; then put the wristband around your wrist with the metal button against your skin.

◆ Use the ESD kit when handling any FRU. If an emergency arises and the ESD kit is not available, follow the procedures in the Emergency Procedures (Without an ESD Kit) section.

Emergency Procedures (Without an ESD Kit) In an emergency when an ESD kit is not available, use the following procedures to reduce the possibility of an electrostatic discharge by ensuring that your body and the subassembly are at the same electrostatic potential.

These procedures are not a substitute for the use of an ESD kit. Follow them only in the event of an emergency.

◆ Before touching any FRU, touch a bare (unpainted) metal surface of the cabinet or storage system.

◆ Before removing any FRU from its antistatic bag, place one hand firmly on a bare metal surface of the storage system, and at the same time, pick up the FRU while it is still sealed in the antistatic bag. Once you have done this, do not move around the room or touch other furnishings, personnel, or surfaces until you have installed the FRU.

◆ When you remove a FRU from the antistatic bag, avoid touching any electronic components and circuits on it.

◆ If you must move around the room or touch other surfaces before installing a FRU, first place the FRU back in the antistatic bag. When you are ready again to install the FRU, repeat these procedures.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 25: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Installing Additional Disks

Add Disk Modules

CAUTION!Disk modules are extremely sensitive electronic components. Always handle a disk module gently, and observe the following guidelines:

◆ Always replace a disk module with another of the same model. Contact your sales/service representative for a list of approved disk replacements.

◆ Follow the instructions in the preceding section, Handling FRUs (page 23).

◆ Always wear a properly attached ESD wristband when removing or replacing a disk module.

◆ Place modules on a soft, antistatic surface, such as an industry-standard antistatic foam pad or the container used to ship the module. Never place a disk module directly on a hard surface.

◆ Never hit modules, stack modules, or allow them to tip over or fall.

◆ Avoid touching any exposed electronic components and circuits on the disk module.

You must remove the storage system’s front bezel to gain access to the disk modules. The bezel is required for EMI compliance when the storage system is powered up. Remove it only to replace or add a disk module.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 25

Page 26: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

26

Installing Additional Disks

Unlock and Remove the Front Bezel Follow these steps to remove the front bezel and gain access to the disk modules (Figure 7).

1. Insert the key that shipped with your storage system into the bezel lock, and turn it to release the lock.

2. Press the two latch buttons on the bezel surface toward each other to release the bezel from the cabinet.

3. Pull the bezel off the cabinet and put it on a clean, static-free surface.

Figure 7 Unlocking and Removing the Front Bezel

EMC2937

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 27: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Installing Additional Disks

Remove a Disk Filler ModuleLocate the slot where you want to install the disk module, and remove the filler module (Figure 8).

Figure 8 Removing a Disk Filler Module

EMC2810

Filler

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 27

Page 28: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

28

Installing Additional Disks

Install a Disk Module1. Make sure an ESD wristband is attached to your wrist and the

storage system (see the precautions on page 24).

2. Align the module with the guides in the slot.

3. Gently push the module completely into the slot (Figure 9). To ensure that the module seats completely, push in on the disk label as you engage the latch.

Figure 9 Installing a Disk Module

The disk module’s Active light flashes to indicate the disk’s spin-up sequence.

EMC2812

Label(Push Here)

Disk

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 29: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Installing Additional Disks

Install and Lock the Front BezelRefer to Figure 10 as you do the following:

1. Align the bezel with the storage system.

2. Gently push the bezel into place on the cabinet until it latches.

3. Secure the bezel by turning the key in the lock.

Figure 10 Installing and Locking the Front Bezel

EMC2935a

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 29

Page 30: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

30

Installing the Switches in the Cabinet

Installing the Switches in the CabinetRead this section if you are installing a new switch.

1. Install each rail in the cabinet (Figure 11).

a. From the front of the cabinet, insert the alignment pin into the rear channel, so the pin goes in the center hole of a 1U space, with 5/8-inch spaces on either side of the hole.

b. Pull the adjustable rail forward, and attach it to the inside of the front channel with screws in the upper and lower of the three holes.

Figure 11 Installing Switch Mounting Rails in a 19-inch NEMA Cabinet

AlignmentPin

EMC2877

Rear

Front

Adjustable Rail

AlignmentPin

Right Front

Screw (2)

SwitchMounting Rail

Right Rear

SwitchMounting Rail

Screw (2)

Alignment Pin

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 31: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Installing the Switches in the Cabinet

2. Attach a slide rail to each side of the switch with two screws per rail (Figure 12).

Figure 12 Attaching Slide Rails to the Switch

3. From the front of the cabinet, insert the slide rails on the side of the switch into the channel on the rails in the cabinet, and push the switch into the cabinet (Figure 13).

Figure 13 Sliding the Switch into the Cabinet

EMC2876

A-B

A-B

A

A

B

A-B

B

A

A

B

A-B

A-B

A

A

B

A-B

A-B

A

A

B

Rear

Front

Switch

EMC2875

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 31

Page 32: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

32

Installing the Switches in the Cabinet

4. Secure the switch and latch brackets to the front channels with a screw on each side (Figure 14).

5. Snap the front bezel onto the latch brackets (Figure 14).

Figure 14 Securing the Switch and Attaching the Front Bezel

What Next? For an AX100SC (single-SP) storage system, continue to the next section, Connecting ac Power to an AX100SC Storage System (page 33).

For an AX100 (dual-SP) storage system, go to Connecting ac Power to an AX100 Storage System (page 37).

A-B

A-B

A

A

B

A-B

A-B

A

A

B

Rear

Front

Switch

EMC2936

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 33: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Connecting ac Power to an AX100SC Storage System

Connecting ac Power to an AX100SC Storage SystemRead this section if you are connecting power to anAX100SC (single-SP) storage system. If you are connecting power to anAX100 (dual-SP) storage system, go to Connecting ac Power to an AX100 Storage System (page 37).

Before You Start

To complete this procedure, you need the ac power cables appropriate to your power source. These cables shipped with the storage system.

Connect ac Power to the AX100SC Storage System

CAUTION!Do not connect the power cord to an ac power source until the storage system and the switches are installed in the cabinet. The storage system powers up as soon as it is connected to an ac source.

As you perform the procedure below, refer to Figure 15.

1. Plug a storage-system power cord into the power connector on the power supply in the storage system.

2. Secure the power cord with the retention bail at the connector.The retention bail prevents the power cord from pulling out of the connector and causing the storage system to power down unexpectedly.

3. Plug the storage-system power cord into the ac power source in the cabinet (power distribution unit) or other source.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 33

Page 34: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

34

Connecting ac Power to an AX100SC Storage System

Figure 15 Connecting ac Power to an AX100SC Storage System

The first time you connect the storage system to an ac power source, it immediately begins to power up: BIOS, POST, and operating system boot. The green power lights (LEDs) on the front and back of the storage system turn on and remain on as long as power is applied to the storage system (Figure 16). The amber SP Boot/Fault light flashes to indicate powerup progress. The Disk Activity lights on the front of the storage system light intermittently as the disks spin up and disk I/O begins.

EMC2950

RetentionBail

ONI

OFFO

ONI

OFFO

ONI

OFFO

ONI

OFFO

ONI

OFFO

ONI

OFFO

EMC2940

AX100SC

04

15

26

37

!

Switch

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 35: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Connecting ac Power to an AX100SC Storage System

When powerup is complete (usually in 5-6 minutes), the SP Boot/Fault light goes off. If the storage system does not power up within several minutes, refer to the "Troubleshoot" section on the AX100 support website or the AX100-Series Documentation CD.

Figure 16 AX100SC Storage-System Lights (LEDs)

If the amber System Fault light is on after powerup, a fault exists somewhere in the storage system. If the amber light specific to a power supply, SP, or disk is on, then that part is faulted.

CAUTION!Press the power button only briefly to power up the storage system. Pressing the power button for more than four seconds while the storage system powers up may affect initialization parameters.

Fault Disk Activity

EMC2934

Power

Front Lights

FE 0

FE 1

Power SP A Boot/Fault Power Supply A FaultEMC2955

SP A

Rear Lights

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 35

Page 36: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

36

Connecting ac Power to an AX100SC Storage System

If You Need to Power Down the Storage SystemFor an orderly shutdown that protects your cache data, use the storage-system power button. The storage system takes a full minute to power down after you press the power button. So after powering down the storage system, wait one minute before powering it on again. If storage-system power is turned off by the power button or by a software shutdown, you must press the power button to re-apply power. If you power down the storage system by unplugging the power cord, the storage system powers up as soon as it is reconnected to the ac power source.

What Next? Go to Connecting the Storage-System and Switch Management Ports (page 42).

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 37: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Connecting ac Power to an AX100 Storage System

Connecting ac Power to an AX100 Storage SystemRead this section if you are connecting power to anAX100 (dual-SP) storage system. If you are connecting power to an AX100SC (single-SP) storage system, go to Connecting ac Power to an AX100SC Storage System (page 33).

Before You Start

To complete this procedure, you need❑ The serial cable that shipped with the UPS. This cable allows

Navisphere Express to monitor UPS status. You may also need an RJ45-DB9 adapter cable that shipped in the AX100-Series accessory box to connect the UPS serial cable to the storage system.

❑ The ac power cables appropriate to your power source. These cables shipped with the storage system.

Connect the UPS Serial Cable to the AX100 Storage System

CAUTION!Be sure to use the unique serial cable supplied with your UPS; a standard null-modem or other service serial cable may look identical, but will not work. You may need to attach an adapter cable to connect the UPS serial cable to the AX100 UPS port.

If the UPS serial cable has two DB9 connectors:

1. Locate an RJ45-DB9 adapter cable in the AX100-Series accessory box.

2. Plug the adapter cable into the UPS serial cable.

3. Plug the free end of the UPS serial cable into the serial port on the UPS (Figure 17).

4. Plug the free end of the adapter cable into the UPS connector (labeled with a +- battery icon) on SP A (Figure 17).

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 37

Page 38: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

38

Connecting ac Power to an AX100 Storage System

If the UPS serial cable has one DB9 and one RJ45 connector:

1. Plug one end of the UPS serial cable into the serial port on the UPS (Figure 17).

2. Plug the free end of the UPS serial cable into UPS connector (labeled with a +- battery icon) on SP A (Figure 17).

Connect ac Power to the AX100 Storage SystemAs you perform this procedure, refer to Figure 17.

CAUTION!Do not connect the power cord to an ac power source until the storage system, the UPS, and the switches are installed in the cabinet. The storage system powers up as soon as it is connected to an ac source.

1. Plug a storage-system power cord into the power connector on both power supplies in the storage system.

2. Secure each power cord with the retention bail at the connector.The retention bail prevents the power cord from pulling out of the connector and causing the storage system to power down unexpectedly.

3. Plug each storage-system power cord into an ac power source as follows:

Do not connect more than one power supply to the UPS.

a. Plug the storage-system power cord connected to the SP A power supply into the power outlet on the UPS.

b. For a 100V or 120V UPS, plug the attached UPS power cord into an ac power source.

c. For a 230V UPS, plug one end of the loose UPS power cord into the UPS power outlet and the other end into an ac power source in the cabinet (power distribution unit).

d. Plug the power cord connected to the SP B power supply into the ac power source in the cabinet (power distribution unit).

Do not connect the SP B power supply to the same power source/circuit as the UPS.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 39: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Connecting ac Power to an AX100 Storage System

Figure 17 Connecting ac Power to an AX100 Storage System

EMC2879a

RetentionBail

To UPS

To PDUPower

ONI

OFFO

ONI

OFFO

ONI

OFFO

ONI

OFFO

ONI

OFFO

ONI

OFFO

+ -

EMC2947

UPS

UPS Serial Cable(Shipped with UPS)

AX100

RJ45-DB9Adapter Cable

110V or 230V Power Cable

(Appropriate to Power Source)

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 39

Page 40: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

40

Connecting ac Power to an AX100 Storage System

The first time you connect the storage system to an ac power source, it immediately begins to power up: BIOS, POST, and operating system boot. The green power lights (LEDs) on the front and back of the storage system turn on and remain on as long as power is applied to the storage system (Figure 18). The amber SP Boot/Fault light flashes to indicate powerup progress. The Disk Activity lights on the front of the storage system light intermittently as the disks spin up and disk I/O begins.

When powerup is complete (usually in 5-6 minutes), the SP Boot/Fault light goes off. If the storage system does not power up within several minutes, refer to the "Troubleshoot" section on the AX100 support website or the AX100-Series Documentation CD.

Figure 18 AX100 Storage-System Lights (LEDs)

If the amber System Fault light is on after powerup, a fault exists somewhere in the storage system. If the amber light specific to a power supply, SP, or disk is on, then that part is faulted.

Fault Disk Activity

EMC2934

Power

Front Lights

FE 0

FE 1

FE 0

FE 1

Power SP A Boot/Fault Power Supply A FaultPower Supply B FaultSP B Boot/FaultEMC2928d

SP B SP A

Rear Lights

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 41: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Connecting ac Power to an AX100 Storage System

CAUTION!Press the power button only briefly to power up the storage system. Pressing the power button for more than four seconds while the storage system powers up may affect initialization parameters.

If You Need to Power Down the Storage SystemFor an orderly storage-system shutdown that protects your cache data, use the storage-system power button (not the UPS power switch). The storage system takes a full minute to power down after you press the power button. So after powering down the storage system, wait one minute before powering it on again. If storage-system power is turned off by the power button or by a software shutdown, you must press the power button to re-apply power. If you power down the storage system by unplugging the power cord, the storage system powers up as soon as it is reconnected to the ac power source.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 41

Page 42: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

42

Connecting the Storage-System and Switch Management Ports

Connecting the Storage-System and Switch Management PortsRead this section if you are installing a new storage system.

You manage the storage system from a management host, which can be a server that has access to the management ports over a specified 10/100 LAN. In addition, when you first set up the storage system, you must initialize it from a host, which can be a server, connected to the same network subnet as the storage-system management ports. The management ports are located on the rear of the chassis and labeled 10/100.

You manage the switch from a host connected to the same network as the switch.

Before You Start

To complete this procedure, you need a standard CAT 5 or higher LAN cable for

❑ Each management port on each storage-system SP that you will connect to the 10/100 LAN

❑ Each switch if you want to manage the switch with the switch vendor’s management software.

Be sure you do not connect the LAN cable to the serial or UPS ports.

Cable the Storage-System and Switch Management Ports to the Network

1. For each SP, connect one end of a LAN cable to the 10/100 management port on the SP and the other end to the network from which you will manage the storage system (Figure 19).

Be sure you do not connect the LAN cable to the serial or UPS ports.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 43: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Connecting the Storage-System and Switch Management Ports

Figure 19 Storage-System LAN Connections (AX100 Shown)

2. If you want to use the switch management software, connect one end of a LAN cable to the LAN management port on each switch and the other end to the network from which you will manage the switch (Figure 20).

EMC3040

UPS

Serial 10/100 - Management LAN Port

Serial 10/100 - Management LAN Port

CAT-5 Cables

Management

10/100 LAN

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 43

Page 44: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

44

Connecting the Storage-System and Switch Management Ports

Figure 20 Switch and LAN Connections (AX100 Shown)

ONI

OFFO

ONI

OFFO

ONI

OFFO

ONI

OFFO

ONI

OFFO

ONI

OFFO

04

15

26

37

!

To LANTo LAN

To LAN

+ -

EMC2956

Switch

AX100

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 45: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Initializing the Storage System

Initializing the Storage SystemRead this section if you are installing a new storage system.

After the storage system is fully powered up for the first time, you need to use the Navisphere Storage System Initialization Utility to initialize it. Initialization sets network parameters for storage-system management and/or creates a management user account for the storage system so you can manage it over the LAN.

You install the Navisphere Storage System Initialization Utility on either a NetWare client or the NetWare host.

Before You StartTo complete this procedure, you need

❑ The completed configuration planning worksheets from Planning Your AX100-Series Fibre Channel Storage-System Configuration in the "Plan" section on the AX100 support website or the AX100-Series Documentation CD.

❑ The storage-system serial number located on a label on the back of the chassis (see below).

❑ A static IP address for each storage processor in the storage system (example, http://123.45.6.7).

❑ The subnet mask of the LAN to which the storage system is connected.

❑ The default gateway address of the LAN to which the storage system is connected.

HW S/N XXX 000NNNNNNNN

EMC3030

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 45

Page 46: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

46

Initializing the Storage System

❑ A NetWare host on the same subnet as the storage system. This requirement is for initialization only.

❑ The AX-Series Server Support CD that shipped with the storage system.

Install the Navisphere Storage System Initialization Utility on a NetWare Client1. Insert the AX-Series Server Support CD into the CD drive of a

NetWare client on the same subnet as the storage system.

2. From the main menu, click Install Products on Server.

3. From the Install Products menu, click Navisphere Storage System Initialization Utility to open the installation wizard.

4. Proceed through the screens until the installation is complete.

A user interface (UI) and a text-based version of the utility are installed.

Start the Navisphere Storage System Initialization Utility on a NetWare Client1. Before continuing, make sure that the storage system is powered

up completely:

• The Fault lights on each SP must be off and the Power light must be on. These lights are on the back of the storage system (Figure 21).

• The amber system Fault light visible from the front of the storage system must be off (Figure 21).

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 47: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Initializing the Storage System

Figure 21 Storage-System Lights (LEDs)

2. Start the Navisphere Storage System Initialization Utility by clicking Start > Programs > EMC > Navisphere > Navisphere Storage System Initialization.

3. Read the license agreement and click I accept and Next.

The utility automatically scans the subnet for AX100-Series storage systems. When this storage-system discovery operation is complete, the utility lists, by hardware serial number, all uninitialized and initialized storage systems it discovered. The hardware serial number is on a label on the rear of the chassis(see page 45).

If the storage system you are installing was not discovered, verify the cable connections between the storage system and the computer running the utility.

FE 0

FE 1

FE 0

FE 1

Power SP A Boot/Fault Power Supply A FaultPower Supply B FaultSP B Boot/FaultEMC2928d

SP B SP A

Rear Lights

Fault Disk Activity

EMC2934

Power

Front Lights

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 47

Page 48: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

48

Initializing the Storage System

Run the Navisphere Storage System Initialization Utility on a NetWare Client1. From the Uninitialized Systems list, select the storage system

and click Next.

2. Using the information from the Storage-System Management Ports section of the completed storage-system configuration planning worksheet, enter the following network parameters for the storage-system 10/100 management ports, and click Next:

3. Enter the name you want for the storage system, which cannot exceed 32 characters.

4. Using the information from the Storage-System Management Ports section of the completed storage-system configuration planning worksheet, enter the following management user account settings for the storage system:

5. Click Next to view the summary of the management user account settings for storage system.

6. If the settings are correct, click Finish.

Storage Processor A - IP IP address for SP A management port.

Storage Processor B - IP IP address for SP B management port.

Subnet Mask Subnet mask associated with the LAN to which the storage-system management port is connected.

Default Gateway Default gateway address for the LAN to which the storage-system management port is connected.

User name User name for the management port. A valid user name must start with a letter, can contain only letters and numbers, cannot exceed 32 characters, and is case sensitive. For example, blindmice3 is a valid user name and is a different name from BLINDMICE3.

Password Password for the user connected to the management port. A valid password can contain only letters and numbers, cannot exceed 32 characters, and is case sensitive. For example, mousetrap2 is a valid password and is a different password from MOUSETRAP2.

Confirm password Previously entered password for password verification.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 49: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Initializing the Storage System

7. In the message box about the storage system having been initialized, click OK.

If you entered an SP IP address for the first time or changed an SP IP address, the utility reboots the storage system and the SP Boot/Fault light on the back of each SP starts blinking (Figure 22). The reboot takes several minutes to complete. When it has completed, the SP Boot/Fault light on each SP stops blinking and remains off.

Figure 22 SP Boot/Fault and Power Supply Fault Lights (AX100 Shown)

If you installed the Navisphere Storage System Initialization Utility on a server (a host that will have data access to the storage-system disks), leave the utilities CD in the drive because you will need it to install the Navisphere Server Utility on the server. If you installed the Navisphere Storage System Initialization utility on a host that you will use only to initialize or manage the storage system (a host that will have no data access to the storage-system disks), remove the CD from the drive.

FE 0

FE 1

FE 0

FE 1

Power SP A Boot/Fault Power Supply A FaultPower Supply B FaultSP B Boot/FaultEMC2928d

SP B SP A

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 49

Page 50: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

50

Initializing the Storage System

Install the Navisphere Storage System Initialization Utility on a NetWare Host1. Insert the AX-Series Server Support CD into the CD drive of the

computer on the same subnet as the storage system.

2. Log in to the NetWare server as a user with privileges for the SYS volume.

You can log in as admin or any user with administrative privileges.

3. From a NetWare client, map a drive to the NetWare server’s SYS volume.

For example:

H:

4. From a NetWare client command prompt, change the directory to the \NETWARE\NAVIINIT directory on the drive containing the CD.

For example:

CD D: \NETWARE\NAVIINIT

5. From a NetWare client command prompt, enter

INSTALL drive

where drive is the remote drive corresponding to the SYS volume on the NetWare server. (For example, INSTALL H: would cause the installation script to create the H:\EMC\NAVIINIT directory with all the subdirectories required for the Navisphere Storage System Initialization Utility.)

6. If DNS is functioning, verify that the IP addresses and names of your DNS servers are registered in the SYS:\ETC\RESOLV.CFG file.

If they are not registered, edit RESOLV.CFG to add the information.

7. On the NetWare server, verify that the SYS:\ETC\HOSTS contains an entry for the server itself, even if you will use DNS.

For example, if the IP address is 10.0.0.1 and the server name is server1, add 10.0.0.1 server1 to the NetWare server’s SYS:\ETC\HOSTS file. The host entry server1 identifies the host and will appear as the visible entry when you assign virtual disks to the server.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 51: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Initializing the Storage System

Run the Navisphere Storage System Initialization Utility on a NetWare Host1. Before continuing, make sure that the storage system is powered

up completely:

• The Fault lights on each SP must be off and the Power light must be on. These lights are on the back of the storage system (Figure 23).

• The amber system Fault light visible from the front of the storage system must be off (Figure 23).

Figure 23 Storage-System Lights (LEDs)

2. At a NetWare console prompt, log in as admin or a user with administrative privileges.

3. Start the Navisphere Storage System Initialization Utility:

LOAD SYS:\EMC\NAVIINIT\NAVIINIT

FE 0

FE 1

FE 0

FE 1

Power SP A Boot/Fault Power Supply A FaultPower Supply B FaultSP B Boot/FaultEMC2928d

SP B SP A

Rear Lights (AX100)

Fault Disk Activity

EMC2934

Power

Front Lights

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 51

Page 52: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

52

Initializing the Storage System

4. Read the license agreement and enter y to accept it.

The utility automatically scans the subnet for AX100-Series storage systems. When this storage-system discovery operation is complete, the utility lists, by hardware serial number, all uninitialized and initialized storage systems it discovered. The hardware serial number is on a label on the rear of the chassis(see page 45).

If the storage system you are installing was not discovered, verify the cable connections between the storage system and the computer running the utility.

5. Enter the item number of the storage system you want to initialize and press Enter.

6. Using the information from the Storage-System Management Ports section of the completed storage-system configuration worksheet, follow the instructions on the screen to change the storage system’s name, if desired, and to set the following network parameters for the storage-system 10/100 management ports:

7. Enter the name you want for the storage system, which cannot exceed 32 characters.

Storage Processor A - IP IP address for SP A management port.

Storage Processor B - IP IP address for SP B management port.

Subnet Mask Subnet mask associated with the LAN to which the storage-system management port is connected.

Default Gateway Default gateway address for the LAN to which the storage-system management port is connected.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 53: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Initializing the Storage System

8. Using the information from the Storage-System Management Ports section of the completed storage-system configuration planning worksheet, follow the instructions on the screen to set the following management user account settings for the storage system.

9. When you have set the parameters to the values you want, apply the values by typing a.

10. Exit the utility by typing e.

If you entered an SP IP address for the first time or changed an SP IP address, the utility reboots the storage system and the SP Boot/Fault light on the back of each SP starts blinking (Figure 24). The reboot takes several minutes to complete. When it is completed, the SP Boot/Fault light on each SP stops blinking and remains off.

Figure 24 SP Boot/Fault and Power Supply Fault Lights (AX100 Shown)

User name User name for the management port. A valid user name must start with a letter, can contain only letters and numbers, cannot exceed 32 characters, and is case sensitive. For example, blindmice3 is a valid user name and is a different name from BLINDMICE3.

Password Password for the user connected to the management port. A valid password can contain only letters and numbers, cannot exceed 32 characters, and is case sensitive. For example, mousetrap2 is a valid password and is a different password from MOUSETRAP2.

Confirm password Previously entered password for password verification.

FE 0

FE 1

FE 0

FE 1

Power SP A Boot/Fault Power Supply A FaultPower Supply B FaultSP B Boot/FaultEMC2928d

SP B SP A

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 53

Page 54: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

54

Initializing the Storage System

Change the Management Network Parameters and User Account SettingsIf you need to change the management network parameters or user account settings after you initialized the storage systems, you must

◆ Shut down the storage system.

◆ Reset the storage system.

◆ Rerun the initialization utility to set the parameters.

To Shut Down the Storage SystemYou can shut down the storage system with Navisphere Express or the power switch.

To Start Navisphere Express1. Open an Internet browser, such as Internet Explorer or Netscape,

on the server or on any host on the same LAN as the storage system.

2. Enter the IP address of an SP in the storage system.

This address is the one you assigned when you initialized the storage system.

If Navisphere Express does not open, make sure that the storage system is not rebooting. When the reboot is complete, the SP Boot/Fault light on the back of each SP is off and not blinking.

If the storage system is not rebooting and Navisphere Express still does not open, go to the "Troubleshoot" section on the AX100 support website or the AX100-Series Documentation CD.

3. Log in to Navisphere Express by entering the username and password that you specified when you initialized the storage system.

To Shut Down the Storage System with Navisphere Express

1. In the Navisphere Express navigation pane under System, click Service.

2. In the System Shutdown page, click Shutdown.

To Shut Down the Storage System with the Power SwitchPress the power button down for about a second.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 55: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Initializing the Storage System

To Reset the Storage System1. After shutting down the storage system, wait about two minutes

for the storage system to power down.

2. Press the power button and hold it down for one second after the green Power light comes on (Figure 25) - a total of about four to five seconds.

Figure 25 Storage-System Power Button and Light (LED)

FE 0

FE 1

FE 0

FE 1

Power LEDEMC2928e

SP B SP A

Power On/Off Button

Rear (AX100)

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 55

Page 56: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

56

Connecting Switches to the Storage System and Server

Connecting Switches to the Storage System and ServerRead this section for all configurations.

Use optical cables to connect switch ports to storage-system Fibre Channel ports (labeled FE 0 and FE 1 on each SP) and to server HBA ports.

Before You StartTo complete this procedure, you need an optical cable for each SP port you will use on the storage system and each switch port you will use. For cable specifications, refer to Technical Specifications in the "Technical descriptions" section on the AX100 support website.

Handling Optical CablesOptical cables are susceptible to damage, so take the following precautions when handling them:

◆ Keep the covers on all optical cables until you are ready to insert them.

◆ Avoid tight bends. If you need to make a 90º bend, do it over 6 to 12 inches.

◆ Do not use optical cables to support weight (including their own, unsupported weight if they are long).

◆ Do not pull long runs of cable; instead, lay the cable in place or pull only a few feet at a time.

◆ Place the cables where no one can step on them or roll equipment over them.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 57: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Connecting Switches to the Storage System and Server

Cable the Switch to the Storage SystemOn the customer-installable switch, use ports 0 and 4 only for SP connection and ports 1-3 and 5-7 only for HBA connections. The switch is preconfigured so that any SP connected to ports 0 or 4 communicates with any HBA connected to ports 1-3 and 5-7.

For highest availability with a multiple-HBA server

◆ Single-SP system - Connect FE 0 to port switch 0 and FE 1 to switch port 4.

◆ Dual-SP system - Connect either FE port on SP A to switch port 0 and either FE port on SP B to switch port 4.

As you perform the procedure below, refer to Figure 26.

1. Remove the protective cover from the optical connector on switch port 0 or switch port 4 and from one end of the optical cable, and plug the cable into the switch port.

2. Remove the protective covers from the FE connector on the SP and from the free end of the optical cable, and plug the cable into the FE connector.

3. For each additional FE port you want to connect to the switch, repeat steps 1 and 2.

Figure 26 Storage-System Front End (FE) and Optical Cable Connectors (AX100 Shown)

F E 0

F E 1

F E 0

F E 1

FE 1FE 0FE 1FE 0

emcn2945

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 57

Page 58: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

58

Connecting Switches to the Storage System and Server

Cable the Switch to the Server1. Remove the protective covers from the HBA port connector on

the server and from one end of the optical cable, and plug the cable into the HBA connector.

2. Remove the protective covers from the free end of the optical cable and from the lowest-numbered unused switch port 1-3, 5-7, and plug the cable into the switch port (Figure 27).

You must use these ports in order from 1-3, 5-7.

3. For each additional switch port that you want to connect to the server, repeat steps 1 and 2.

4. Power up the switch.

Figure 27 Switch Connections (Sample AX100 Cabling Shown)

ONI

OFFO

ONI

OFFO

ONI

OFFO

ONI

OFFO

04

15

26

37

!

+ -

EMC2927b

Switch

AX100

04

15

26

37

To SP

To SP

To Server HBA

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 59: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Registering the Server with the Storage System

Registering the Server with the Storage SystemRead this section for all configurations.

You must run the Navisphere Server Utility on each server connected to the storage system to register the server’s HBAs with the storage system.

Run the Server Utility to Register the Storage System with the Server

1. At a NetWare console, log in as a user with administrative privileges.

2. From the NetWare console enter

LOAD SYS:\EMC\NAVIHOST\AXNAVHST

If the server utility does not start, the storage system may still be rebooting. When the reboot is complete, the SP Boot/Fault light on the back of each SP is off and not blinking. If the reboot is complete, try running the utility again. If the utility still does not start, you may have an early version of AX Server Utility. Try starting it by entering LOAD SYS:\EMC\NAVIHOST\NAVIHOST.

3. In the Server Utility, enter 1 to select Update Server Information.

The utility automatically scans for connected AX100-Series storage systems, and displays a list of the ones it finds.

4. In the Server Utility, enter u to register the server with each storage system the utility found.

The utility sends to each storage system the server’s name and IP address and the NetWare device name and volume or file system information for each virtual disk in the storage system that the server sees.

5. Enter c (cancel) to stop the utility.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 59

Page 60: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

60

Registering the Server with the Storage System

Start Navisphere Express1. Open an Internet browser, such as Internet Explorer or Netscape,

on the server or on any host on the same LAN as the storage system.

2. Enter the IP address of an SP in the storage system.

The IP address is one you assigned when you initialized the storage system (from the Storage-Management Ports section of the planning guide).

If Navisphere Express does not open, make sure that the storage system is not rebooting. When the reboot is complete, the SP Boot/Fault light on the back of each SP is off and not blinking.

If the storage system is not rebooting and Navisphere Express still does not open, go to the "Troubleshoot" section on the AX100 support website or the AX100-Series Documentation CD.

3. Log in to Navisphere Express by entering the username and password.

The username and password are the ones that you specified when you initialized the storage system (from the Storage-Management Ports section of the planning guide).

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 61: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Registering the Server with the Storage System

Verify HBA Registration1. In the Navisphere Express navigation pane, under Manage, click

Connections to display the Manage Connections page.

2. Verify that the SP/Port status is Active for each HBA connected to the storage system.

• If the status is Active (unregistered), register the HBA with the storage system by running the Navisphere Server Utility as described in Registering the Server with the Storage System (page 59).

• If the status is Inactive, either the physical connection between the HBA and the storage system is faulty or the storage system is not powered up. Go to the "Troubleshoot" section on the AX100 support website or the AX100-Series Documentation CD.

What Next? For a new storage system, continue to the next section, Configuring a New Storage System (page 62).

For an existing storage system, go to Configuring an Existing Storage System (page 66).

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 61

Page 62: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

62

Configuring a New Storage System

Configuring a New Storage SystemRead this section if you are configuring a new AX100SC or AX100 storage system. A new storage system is one that was not already connected to a server when you started the installation procedure.

Before You Start

You need to complete the configuration planning worksheets from Planning Your AX100-Series Fibre Channel Storage-System Configuration in the "Plan" section on the AX100 support website or the AX100-Series Documentation CD.

Start Navisphere Express If It Is Not Already Running

1. Open an Internet browser, such as Internet Explorer or Netscape, on the server or on any host on the same LAN as the storage system.

2. Enter the IP address of an SP in the storage system.

This address is the one you assigned when you initialized the storage system.

If Navisphere Express does not open, make sure that the storage system is not rebooting. When the reboot is complete, the SP Boot/Fault light on the back of each SP is off and not blinking.

If the storage system is not rebooting and Navisphere Express still does not open, go to the "Troubleshoot" section on the AX100 support website or the AX100-Series Documentation CD.

3. Log in to Navisphere Express by entering the username and password that you specified when you initialized the storage system.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 63: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Configuring a New Storage System

Configure a New Storage System1. Locate your completed storage-system configuration planning

worksheet so you can refer to it in the steps that follow.

2. Create a hot spare.

A hot spare is a single global spare disk that serves as a temporary replacement for any failed disk in the storage system. The storage system automatically reconstructs data from the failed disk onto the hot spare, so the data is always available.

To create a hot spare - in the Navisphere Express navigation pane, under Manage, click Hot Spare. For details on creating a hot spare, use the Navisphere Express Help Center.

3. Create one or more disk pools on which to create virtual disks.

A disk pool is a set of disks, all with the same capacity and redundancy, on which you create one or more virtual disks. A RAID 5 disk pool must include at least three disks and a RAID 1/0 must include at least two disks. The storage system supports a maximum of six disk pools.

To create a disk pool - In the Navisphere Express navigation pane, under Manage, click Disk Pools. For details on creating a disk pool, use the Navisphere Express Help Center.

For an AX100 (dual-SP) storage system, you should create at least two disk pools, since the software assigns each disk pool you create to an SP as follows: disk pool 1 to SP A, disk pool 2 to SP B, disk pool 3 to SP A, and disk pool 4 to SP B. All the virtual disks you create on a disk pool are automatically assigned to the same SP as the disk pool, so if you create only one disk pool on an AX100 storage system, all virtual disks on the storage system are assigned to SP A and all data received or sent goes through SP A only.

The disk modules marked 0 through 3 contain storage-system software or reserved space according to their slot assignment. Do not move any disk marked 0 through 3 from its assigned slot. Remove it only to replace the disk module. Part of the space on these disks is reserved or preloaded with system data, and as a result, is not available for your data. If you combine

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 63

Page 64: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

64

Configuring a New Storage System

operating system disks in a disk pool with other disks, each of the other disks loses space for your data equal to the system data space on an operating system disk.

4. Create one or more virtual disks on the disk pools.

A virtual disk is a grouping of disk partitions into one span of disk storage space. Each virtual disk you create is distributed equally across the disks in the disk pool. A virtual disk looks like an individual disk to the server's operating system. Each disk pool supports 128 virtual disks.

To create a virtual disk, in the Navisphere Express navigation pane, under Manage, click Virtual Disks. For details on creating a virtual disk, use the Navisphere Express Help Center.

If you want to connect additional servers to the storage system, you can create virtual disks for them now. You have to wait until the servers are connected and registered before you can assign these virtual disks to them.

5. Assign one or more virtual disks to the server.

To send data to or receive data from the virtual disks, you must assign the virtual disks to a server.

To assign a virtual disk to a server - In the Navisphere Express navigation pane, under Manage, click Virtual Disks.

For details on assigning a virtual disk to a server, use the Navisphere Express Help Center.

6. Verify that the virtual disks were assigned to the server by looking at the Manage Servers page.

To display the Manage Servers page - In the Navisphere Express navigation pane, under Manage, click Servers.

You should see the virtual disks you assigned to the server listed in the Virtual Disks column of the server’s row.

If you do not see virtual disks, go to the "Troubleshoot" section on the AX100 support website or the AX100-Series Documentation CD.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 65: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Configuring a New Storage System

7. Use the Event Notification page to configure the storage system to send an E-mail message when the storage system encounters a problem.

To display the Events Notification page - In the Navisphere Express navigation pane, under System, click Settings, and then click Event Notification.

For details on configuring the storage system to send E-mail messages, use the Navisphere Express Help Center.

8. Configure PowerPath:

/etc/opt/emcpower/powercf -qpowermt config

9. On the server, verify that PowerPath sees all the paths to the virtual disks with the PowerPath command:

powermt display dev=all

What Next? Go to Preparing Virtual Disks to Receive Data (page 69).

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 65

Page 66: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

66

Configuring an Existing Storage System

Configuring an Existing Storage SystemRead this section if you are configuring an existing AX100SC or AX100 storage system. An existing storage system is one that was already connected to a server when you started the installation procedure.

Before You Start

You need to complete the configuration planning worksheets from Planning Your AX100-Series Fibre Channel Storage-System Configuration in the "Plan" section on the AX100 support website or the AX100-Series Documentation CD.

Start Navisphere Express If It Is Not Already Running

1. Open an Internet browser, such as Internet Explorer or Netscape, on the server or on any host on the same LAN as the storage system.

2. Enter the IP address of an SP in the storage system.

This address is the one you assigned when you initialized the storage system.

If Navisphere Express does not open, make sure that the storage system is not rebooting. When the reboot is complete, the SP Boot/Fault light on the back of each SP is off and not blinking.

If the storage system is not rebooting and Navisphere Express still does not open, go to the "Troubleshoot" section on the AX100 support website or the AX100-Series Documentation CD.

3. Log in to Navisphere Express by entering the username and password that you specified when you initialized the storage system.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 67: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Configuring an Existing Storage System

Configure an Existing Storage System1. Locate your completed storage-system configuration planning

worksheet so you can refer to it in the steps that follow.

2. If you need additional disk pools for virtual disks for the server, create one or more disk pools.

A disk pool is a set of disks, all with the same capacity and redundancy, on which you create one or more virtual disks. A RAID 5 disk pool must include at least three disks and a RAID 1/0 must include at least two disks. The storage system supports a maximum of six disk pools.

To create a disk pool - In the Navisphere Express navigation pane, under Manage, click Disk Pools. For details on creating a disk pool, use the Navisphere Express Help Center.

The disk modules marked 0 through 3 contain storage-system software or reserved space according to their slot assignment. Do not move any disk marked 0 through 3 from its assigned slot. Remove it only to replace the disk module. Part of the space on these disks is reserved or preloaded with system data, and as a result, is not available for your data. If you combine operating system disks in a disk pool with other disks, each of the other disks loses space for your data equal to the system data space on an operating system disk.

3. If you need additional virtual disks for the server, create one or more virtual disks on the disk pools.

Each disk pool supports a maximum of 128 virtual disks.

To create a virtual disk - In the Navisphere Express navigation pane, under Manage, click Virtual Disks. For details on creating a virtual disk, use the Navisphere Express Help Center.

4. Assign one or more virtual disks to the server.

To send data to or receive data from the virtual disks, you must assign the virtual disks to a server.

To assign a virtual disk to a server - In the Navisphere Express navigation pane, under Manage, click Virtual Disks.

For details on assigning a virtual disk to a server, use the Navisphere Express Help Center.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 67

Page 68: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

68

Configuring an Existing Storage System

5. Verify that the virtual disks were assigned to the server by looking at the Manage Servers page.

To display the Manage Servers page - In the Navisphere Express navigation pane, under Manage, click Servers.

You should see the virtual disks you assigned to the server listed in the Virtual Disks column of the server’s row.

If you do not see virtual disks, go to the "Troubleshoot" section on the AX100 support website or the AX100-Series Documentation CD.

6. Configure PowerPath:

/etc/opt/emcpower/powercf -qpowermt config

7. On the server, verify that PowerPath sees all the paths to the virtual disks with the PowerPath command:

powermt display dev=all

What Next? Go to Preparing Virtual Disks to Receive Data (page 69).

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 69: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Preparing Virtual Disks to Receive Data

Preparing Virtual Disks to Receive DataRead this section for all configurations.

Before NetWare can access a virtual disk, you must create a partition and volume on it.

Create and Mount NWFS Partitions and Volumes on Virtual Disks

NetWare Cluster Service requires NSS (not NWFS) partitions and volumes. To create NSS partitions and volumes, go to Create NetWare NSS Partitions on Virtual Disks (page 71).

Create NetWare NWFS Partitions on Virtual Disks1. Before continuing, make sure the virtual disks you created are

completely (100 percent) initialized.

a. Start Navisphere Express.

b. In the Navisphere Express navigation pane under Manage, click Virtual Disk.

c. In the Manage Virtual Disks screen, if the status of any virtual disk is Initializing, wait until the initialization is complete.

2. At the NetWare server command, type

NWCONFIG

3. From the Configuration Options menu, follow the path:

Standard Disk Options > Modify Disk Partitions and Hot Fix

4. From the Available Disk Drives list, select the virtual disk you want to partition.

If a partition table has never been created on the selected drive, a dialog box appears saying so. In this dialog box, you can press Enter to continue because creating the partition as follows also creates the partition table.

5. In the Initializing the Partition Table dialog box, click Yes.

6. From the Disk Options menu, select Create NetWare disk partitions.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 69

Page 70: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

70

Preparing Virtual Disks to Receive Data

7. In the Disk Partition Information dialog box:

a. Accept or decrease the NetWare partition size.

b. Accept or change the size of the data area or the hot fix redirection area.

c. Press ESC and click Yes at the prompt to create the partition.

8. For each additional disk that you want to partition, repeat steps 4 through 7.

What Next? To create and mount NWFS volumes, continue to the next section.

Create and Mount NetWare NWFS Volumes1. From the Configuration Options menu, click NetWare Volume

Options, and then follow the path:

Standard Disk Options > Netware Volume Options.

2. From the list of volume disk segments with free space available, select the partition on which to create the volume.

3. Click Make this segment a new volume.

4. In the Disk Segment Parameters dialog box:

a. Enter the disk segment volume name.

b. Enter the disk segment size.

c. Press F10 to return to the Volume Disk Segment list.

5. Press ESC to return to Volume List.

6. To create additional volumes, repeat steps 2 through 5.

7. Press ESC and click Yes to save your volume changes.

If you have directory services configured, you must enter your administrator name and password before the volume is created. The volumes are created and a dialog box informs you of the number of volumes that were installed in the directory.

8. Press Enter to continue.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 71: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Preparing Virtual Disks to Receive Data

9. If you want to mount all volumes now, from the Select an Action menu, select Mount all volumes.

If you want to mount some, but not all, volumes now, press ESC repeatedly until the Configuration Options menu appears. Then exit the NWCONFIG utility. At the NetWare server command prompt, for each volume you want to mount, enter a mount command in the form:

mount volume_name

where volume_name is the name you specified in step 4a.

The server can now write to and read from the volumes.

What Next? Go to Save the PowerPath Configuration (page 72).

Create and Mount NSS Partitions and Volumes on Virtual DisksNSS Volumes are required for Novell Cluster Services on NetWare 5.X.

Create NetWare NSS Partitions on Virtual Disks1. At the NetWare server command prompt, enter this command:

NWCONFIG

2. From the Configuration Options menu, follow the path:

NSS Disk Options > Storage

3. From the Available NSS Storage Options menu, select Update Provider Information and then select MMPRV-NSS Media Manager Provider.

4. Press any key to continue.

5. From the Available NSS Storage Options menu, select Assign Ownership.

6. From the NSS menu, select a storage deposit (free space) for the NSS partition.

7. Enter a size for the partition, or accept the default.

8. Select Yes to confirm your choice.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 71

Page 72: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

72

Preparing Virtual Disks to Receive Data

9. When the Available NSS Storage Options menu reappears, press ESC.

10. For each additional disk that you want to partition, repeat steps 5 through 9.

Create and Mount NetWare NSS Volumes1. At the NetWare server command prompt enter

NWCONFIG

2. From the Configuration Options menu, follow the path:

NSS Disk Options > NSS Volume Options

3. Enter your administrator name and password to authenticate to NDS.

4. From the Available NSS Options menu, select Create.

5. From the Create Options menu, select NSS Volume.

6. From the Select a Managed Object menu, select the NSS partition where you want to create the NSS volume.

7. Enter the name of the NSS volume.

8. Select Yes to confirm your decision.

9. For each partition you created in the previous section, create a volume as in steps 4 through 8.

10. When you finish creating volumes, press ESC repeatedly until the Configuration Options menu appears. Then exit the NWCONFIG utility.

11. At the NetWare server command prompt, for each volume you want to mount, enter the mount command:

mount volume_name

where volume_name is the name you specified in step 7.

The server can now write data to and read from the volumes.

Save the PowerPath Configuration

Save the server’s PowerPath configuration:

powermt save

This command creates the powermt.ctm configuration file.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 73: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Sending NetWare Disk Information to the Storage System

Sending NetWare Disk Information to the Storage SystemRead this section for all configurations.

You must rerun the Navisphere Server Utility to send to the storage system the NetWare device name and volume or file system information for each virtual disk that the server sees. Navisphere Express displays this information on its Details page for each virtual disk.

Start the Server Utility

From the NetWare console enter

LOAD SYS:\EMC\NAVIHOST\AXNAVHST

If the server utility does not start, the storage system may still be rebooting. When the reboot is complete, the SP Boot/Fault light on the back of each SP is off and not blinking. If the reboot is complete, try running the utility again. If the utility still does not start, you may have an early version of the AX Server Utility. Try starting it by entering LOAD SYS:\EMC\NAVIHOST\NAVIHOST.

The utility automatically scans for connected AX100-Series storage systems, and displays a list of the ones it finds.

Register the Server with the Storage System

In the Server Utility, enter u to register the server with each storage system the utility found.

The utility sends to each storage system the server’s name and IP address and the NetWare device name and volume or file system information for each virtual disk in the storage system that the server sees.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 73

Page 74: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

74

Verifying Your Configuration

Verify That the Storage System Received the Disk Information1. For each virtual disk in the storage system that is connected to the

server, display its Navisphere Express Details page:

a. In the Navisphere Express navigation panel, under Manage, click Virtual Disks.

b. On the Manage Virtual Disk page, click the virtual disk to display its Details page.

2. Verify that the Details page displays the volume or file system and device name for the virtual disk.

Verifying Your ConfigurationRead this section for all configurations.

Before you store data on virtual disks, you should use the procedure below to verify that:

◆ The server can send data to the storage system.

◆ PowerPath shows the paths from the server to the virtual disk that you expect for your configuration.

Before You StartIf you are not familiar with PowerPath, read PowerPath in Action in the "Technical descriptions" section on the AX100 support website or the AX100-Series Documentation CD.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server

Page 75: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

Verifying Your Configuration

Verify Your Configuration with PowerPath1. Save the server’s PowerPath configuration with the following

PowerPath command:powermt save

This command creates the powermt.ctm configuration file.

2. If you connected a new server to an existing storage system, stop all applications accessing the storage system and disable user logins to the server.

3. View the virtual disks available to the server:

powermt display dev=all

4. Choose one available virtual disk to receive data (I/O) for the test.

5. View the paths to the chosen virtual disk:

powermt display dev=x every=2

where x is a pseudo device that represents the chosen virtual disk.

6. Start sending data to a virtual disk by writing data to it.

7. Identify the HBA sending data to the virtual disk by viewing the output of the powermt display dev=x every=2 command, and disconnect the cable to that HBA.

8. View the output of the powermt display dev=x every=2 command, and verify that:

• The state of the uncabled paths becomes “dead.”

• Data continues to be sent on the remaining path(s) to the virtual disk, indicating that the failover path was successful and that PowerPath is working properly.

If PowerPath is not working properly, refer to the "Troubleshoot" section on the AX100 support website or the AX100-Series Documentation CD.

9. Reconnect the cable that you disconnected from the HBA.

10. If you caused any virtual disks to fail over, restore the disks to their original SP:powermt restore

11. For each HBA connected to the storage system, repeat steps 3 through 10.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 75

Page 76: AX100-Series -- Installing a Fibre Channel Storage …AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server 3 Terminology Terminology

76

Verifying Your Configuration

What Next? You have completed the installation for one storage system connected to one server. If you have another server to connect to the storage system, start with Installing HBAs in the Server (page 7). If you have another storage system to connect to a server, start with

◆ Unpacking the Storage System (page 17) for a new AX100SC storage system

◆ Installing the UPS (AX100 Only) (page 16) for a new AX100 storage system

◆ Connecting Switches to the Storage System and Server (page 56) for an existing storage system

Copyright © 2004-2005 EMC Corporation. All Rights Reserved.

EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without notice.

THE INFORMATION IN THIS PUBLICATION IS PROVIDED "AS IS." EMC CORPORATION MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WITH RESPECT TO THE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Use, copying, and distribution of any EMC software described in this publication requires an applicable software license.Trademark Information

EMC2, EMC, CLARiiON, Navisphere, and PowerPath are registered trademarks and Access Logix, FLARE, MirrorView, SAN Copy, and SnapView are trademarks of EMC Corporation.All other trademarks mentioned herein are the property of their respective owners.

AX100-Series - Installing a Fibre Channel Storage System with a Switch Connection to a NetWare Server