2
AWS INVERTER COOLING CAPACITY FROM 640 TO 1800 KW Engineered for flexibility and performance™ KBRAC00907-12EN - McQuay reserves the right to change design and specifications without prior notice. A Global Leader In System Solutions for Air Conditioning, Heating, Ventilating and Refrigeration McQuay Italia S.p.A. - Via Piani di Santa Maria, 72 - 00040 Ariccia - Roma - Italy T. +39 06.937311 - F. +39 06.9374014 - www.mcquayeurope.com McQuay (UK) Ltd. - 69 Questor Estate - Pearsons Way - Dartford - Kent DA1 1JN T. +44 01322.424950 - F. +44 01322.424951 - [email protected] Misto Gruppo di prodotti provenienti da foreste correttamente gestite, da altre provenienze controllare e da legno o fibre riciclate www.fsc.org Cert no. SA-COC-002023 © 1996 Forest Stewardship Council AIR COOLED CHILLERS INVERTER ‘AWS’ Family 620÷2000 kW R134a Single Screw with VFD McQuay EFFICIENCY LEADERSHIP TIPICAL SCREW CHILLER EFFICIENCY LEVELS ‘McEnergy’ Family 100÷620 kW R134a Single Screw with VFD ACZC Family 170÷680 kW R410A MultiScroll STEP 1 STEP 2 CHOOSE McQuay CHILLER CHOOSE McQuay AIR HANDLER OR TERMINAL UNIT AWS INVERTER PROVIDES MINIMUM INRUSH CURRENT COMPARED TO TRADITIONAL STARTING METHODS. The use of variable speed motors eliminates the fluctuations on the power supply line and reduces the stress on the electrical equipment. This allows to reduce size (and costs!) of the protection devices to be installed on the power supply line. AWS INVERTER UNITS ARE FEATURING AN AMAZING 0,97 DISPLACEMENT POWER FACTOR AT WHATEVER CHILLER LOAD AND OPERATING CONDITION. It allows minimum current absorption and consequently reducing the cost of the electrical installation. AWS Inverter does not require the installation of traditional capacitors for power factor correction and avoiding potential penalties related to reactive power. Amp limit due to existing electrical installation EXISTING UNIT Installed cooling capacity INSTALLATIONS AMPERE LIMIT cooling capacity cooling capacity +25% +50% 0.8 POWER FACTOR 0.85 POWER FACTOR POWER FACTOR 0.97 INCREASE COOLING OUPUT WITHOUT CHANGING THE EXISTING POWER SUPPLY LINE! AWS Inverter superior energy efficiency combined with the highest possible displacement power factor allows to increase the installed cooling capacity (up to +50%) without modifying the existing power supply line. AWS FAMILY 750 700 650 600 KW 1000 1250 1500 800 1050 1300 1550 850 1100 1350 1600 1750 900 1150 1400 1650 1800 950 1200 1450 1700 1850 1900 AWS SE AWS XE AWS PREMIUM AWS Inverter ESEER 5.8 ESEER 4.6 ESEER 4.3 ESEER 4 640 820 750 640 1800 1300 1860 1720 ESEER Easdale International Infinity (800 m 3 /h - 140.000 m 3 /h) Floor Standing MFU (3,5 kW - 11,0 kW) Cassette MCK-A (1,2 kW - 8,0 kW) Ducted MCW (2,2 kW - 9,4 kW) Easdale Infinity Essential (500 m 3 /h - 30.000 m 3 /h) MINIMUM INRUSH CURRENT MINIMUM INRUSH CURRENT MAX POWER FACTOR MAX POWER FACTOR EFFICIENCY CLASS C EFFICIENCY CLASS A EFFICIENCY CLASS A APPLIED SYSTEM R-134a

AWS fAmIly - · PDF fileMcQuay “AWS Inverter” highest efficiency at both full and part load AWS Inverter series offers the highest eer part load values in the hvac air cooled chiller

  • Upload
    lamlien

  • View
    215

  • Download
    3

Embed Size (px)

Citation preview

Page 1: AWS fAmIly - · PDF fileMcQuay “AWS Inverter” highest efficiency at both full and part load AWS Inverter series offers the highest eer part load values in the hvac air cooled chiller

AWS InverterCoolIng CApACIty from 640 to 1800 kW

Engineered for flexibility and performance™

KB

RA

C00

907-

12E

N -

McQ

uay

rese

rves

the

right

to c

hang

e d

esig

n an

d s

pec

ifica

tions

with

out p

rior

notic

e.

A Global Leader In System Solutions for Air Conditioning, Heating, Ventilating and Refrigeration

McQuay Italia S.p.A. - Via Piani di Santa Maria, 72 - 00040 Ariccia - Roma - ItalyT. +39 06.937311 - F. +39 06.9374014 - www.mcquayeurope.comMcQuay (UK) Ltd. - 69 Questor Estate - Pearsons Way - Dartford - Kent DA1 1JNT. +44 01322.424950 - F. +44 01322.424951 - [email protected]

MistoGruppo di prodotti provenienti daforeste correttamente gestite, da altre provenienze controllare e da legno o �bre riciclatewww.fsc.org Cert no. SA-COC-002023© 1996 Forest Stewardship Council

AIr CooleD CHIllerSInverter

‘AWS’ family 620÷2000 kWr134a Single Screw with vfD

mcQuay effICIenCy leADerSHIp

tIpICAl SCreW CHIller effICIenCy levelS

‘mcenergy’ family 100÷620 kWr134a Single Screw with vfD

ACZC family 170÷680 kWr410A multiScroll

Step 1

Step 2

CHooSe mcQuay CHIller

CHooSe mcQuay AIr HAnDler or termInAl UnIt

AWS Inverter provides minimum inrush current compared to traditional starting methods.The use of variable speed motors eliminates the fluctuations on the power supply line and reduces the stress on the electrical equipment.This allows to reduce size (and costs!) of the protection devices to be installed on the power supply line.

AWS Inverter units are featuring an amazing 0,97 displacement power factor at whatever chiller load and operating condition.It allows minimum current absorption and consequently reducing the cost of the electrical installation.AWS Inverter does not require the installation of traditional capacitors for power factor correction and avoiding potential penalties related to reactive power.

Amp limit due to existing electrical

installation

EXISTINGUNIT

Installed cooling capacity

InstallatIons ampere lImIt

cooling capacity

cooling capacity

+25%

+50%

0.8poWer FaCtor

0.85poWer FaCtor

poWer FaCtor

0.97

IncreASe coolIng ouput WIthout chAngIng the exIStIng poWer Supply lIne!AWS Inverter superior energy efficiency combined with the highest possible displacement power factor allows to increase the installed cooling capacity (up to +50%) without modifying the existing power supply line.

AWS fAmIly

750700650600kw 1000 1250 1500800 1050 1300 1550850 1100 1350 1600 1750900 1150 1400 1650 1800950 1200 1450 1700 1850 1900

AWS Se

AWS Xe

AWS premIUm

AWS Inverter eSeer 5.8

eSeer 4.6

eSeer 4.3

eSeer 4

640

820

750

640

1800

1300

1860

1720

eSee

r

Easdale International Infinity(800 m3/h - 140.000 m3/h)

floor Standing mfU(3,5 kW - 11,0 kW)

Cassette mCk-A(1,2 kW - 8,0 kW)

Ducted mCW(2,2 kW - 9,4 kW)

Easdale Infinity Essential(500 m3/h - 30.000 m3/h)

MINIMUM INRUSH CURRENT

MINIMUM INRUSH CURRENTMAX POWER FACTOR

MAX POWER FACTOR

EFFICIENCY

CLASS C

EFFICIENCY

CLASSA

EFFICIENCY

CLASSA

APPLIED SYSTEM

r-134a

Page 2: AWS fAmIly - · PDF fileMcQuay “AWS Inverter” highest efficiency at both full and part load AWS Inverter series offers the highest eer part load values in the hvac air cooled chiller

McQuay “AWS Inverter” highest efficiency at both full and part loadAWS Inverter series offers the highest eer part load values in the hvac air cooled chiller market, up to 36 % better than traditional technology. this allows a significant reduction of the system running costs in compliance with the most stringent requirements in terms of energy consumption and environmental regulations. these aspects, together with building sustainable design, are becoming more and more crucial factor in the real estate market. aws inverter leads the industry in energy efficiency, quiet operation and responsible refrigerant management: ideal for building owners who want to pursue leadership in energy and environmental design (leed®).

The combination of variable speed single screw compressor and chiller control logic allow to automatically modulate the fan speed to achieve the optimum head pressure set-point and consequencely the best global chiller energy performanceat part load. Resulting ESEER values are 25% higher than traditional screw units, reaching the highest ESEER values for this technology.

12 dB(A) noISe reDUCtIon to meet tHe moSt StrIngent regUlAtIonSDuring the night, when the background noise is decreasing, the acoustical impact of a chiller becomes more critical for neighbors that want quiet. At these conditions the outdoor temperature is lower as well as the cooling load.

AWS Inverter works in partial regime and the inverter devices adjust the speed of compressors and fans supplying the required cooling output and providing better sound performances.

ExtrEmEly WidE rangE ofopEration, With outsidE ambiEnt up to 50°C

AWS Inverter is equipped with mcQuay single-screw compressor and its condensing section is properly sized in order to achieve +50°c ambient temperature and still allowing stepless unloading down to 8% capacity. (referred to three compressors model)differently from other technologies available on market (eg. centrifugals) with single screw compressor no any unefficient “on-off” operation will be experienced at part loads.thanks to this unique design aws inverter is featuring one of the widest working envelope of the market.

saving footprint & installation timE

AWS Inverter are lighter and smaller than other air cooled chillers available from the market. its compact footprint is ideal for replacement projects, allowing easy transport and installation thus resulting in structural elements cost savings. singlE-sCrEW ComprEssor:

mCQuay «in housE» tEChnology

compressor, the “heart” of the chiller, is fully developed, manufactured and serviced by mcQuay.mcQuay single screw compressor inverter driven: the top of screw tecnology with integrated oil separator, best energy efficiency both at full and part loads and with a proven reliability thanks thousands units running all around the world.

plug & play unit ConCEpt

AWS Inverter design allows faster chiller installation with consequent reduction of commissioning cost.• Standard factory functional test• Full refrigerant and oil charge• Integrated Control Logic• Single evaporator• Single main power connection point• Optional on-board inline dual-pumps

in-built rEdundanCy“multiplE units” on a singlE skidAWS Inverter is designed with 2 or 3 (depending on capacity) independent refrigerant circuits.all critical components (e.g. compressor, eeXv ecc…) are independent on each circuit allowing highest reliability standards.

pid ControllEr With optimizEd mCQuay softWarE and ‘nEtWork rEady’ fEaturEs

AWS Inverter is equipped with on-board pid controller, with a standard user-friendly in-built display, or an optional graphical touch screen. controller is ready to be integrated with a wide range of bms through standad communication

protocols. the controller’s display allows viewing of the unit’s operating status and its multi-button keypad and rolling wheel allows

the operator easy access to the unit main functions.

from 100% loAD

continuous modulation

to 8% loAD

Single Shell&Tube Evaporator

equipped with Victaulic

connections for an easy and fast

hydraulic unit connection

Water pump selectableaccording to custom

available pressure needs

aWs Inverter 1.000 kW unit 8.5 meters long

tipical competitor 1.000 kW unit11 meters long

1.5 m less

1 2

* Based on AWS INVERTER 230.2 ST rated at 700 kW, with 12/7 °C Evap. and 35 °C OAT

Single Power Connection Point to semplify the installation reducing systems start-up costs

Single Screw Compressor

Single Screw Compressor

Electronic Expansion Device(EXXV)

Electronic Expansion

Device(EXXV)

Coils Coils

50AMBIENT

°C

*