13
By : [email protected] / [email protected] PDS/PDMS Engineer MANUAL OF AUTOMATIC PIPE ROUTING USING PDMS - Klik Aveva>PDMS 12.0>Run PDMS

Auto_Pipe_routing_manual

Embed Size (px)

DESCRIPTION

Indonesian language auto pipe router pdms

Citation preview

By : [email protected] / [email protected] PDS/PDMS Engineer

MANUAL OF AUTOMATIC PIPE ROUTING USING PDMS

- Klik Aveva>PDMS 12.0>Run PDMS

By : [email protected] / [email protected] PDS/PDMS Engineer

- Pilih SITE ROUTERSITE pada Design Explorer > Add

- Pilih Design>Pipework

By : [email protected] / [email protected] PDS/PDMS Engineer

- Set Default Pipe Specifications - Pilih A1A > OK

- Create>Pipe

- Kasih nama : misal P2>Enter>OK

By : [email protected] / [email protected] PDS/PDMS Engineer

- OK

- Head to Nozzle > Apply>klik Nozzle Pompa

- Tail to Nozzle>Apply> klik Nozzle Vessel>Dismiss

By : [email protected] / [email protected] PDS/PDMS Engineer

By : [email protected] / [email protected] PDS/PDMS Engineer

- Untuk memunculkan Pipe Router, klik : Utilities>Pipe Router

- Posisi pada Pipe P1 pada Design Explorer (pipe / line number yang mau di Add ke Pipe Router)

- Pada Pipe Router pada Add : CE (pilih CE)

By : [email protected] / [email protected] PDS/PDMS Engineer

- Kemudian pilih P1 : P1/B1 : Not Routed (pada Pipe Router)

- Selanjutnya Pilih : Route : Selected (pada Pipe Router)

By : [email protected] / [email protected] PDS/PDMS Engineer

- Ulangi langkah di atas untuk membuat pipe P1

- Cara memasang komponen, misalnya Valve - Posisi di branch P2/B1 pada Design Explorer, lalu create component - Pilih Valve(Gate Valve)>connect>Done

By : [email protected] / [email protected] PDS/PDMS Engineer

- Pindahkan posisi valve ke tail - Pada Pipe Router > Klik Branch Detail...

- Pada Branch Detail klik : Modify>Toggle Head/Tail Relative (pilih terlebih dahulu Valve1 pada Branch Detail pada components/Constrains)

By : [email protected] / [email protected] PDS/PDMS Engineer

- Lalu pada Pipe Router pilih Pipe P2 kemudian pilih : Route = Selected

By : [email protected] / [email protected] PDS/PDMS Engineer

- Insert Valve pada pipe P1(caranya sama seperti Valve1 pada Pipe P2)

- Klik Branch Detail... pada Pipe Router

By : [email protected] / [email protected] PDS/PDMS Engineer

- Klik pada Branch Detail : Modify>Tail W-P

By : [email protected] / [email protected] PDS/PDMS Engineer

- Pada Modify Tail W-P pilih VALVE 1>OK - Posisi pada Pipe P1 (pada Pipe Router) - Lalu pada Pipe Router pilih : Route = Selected (pilih selected)