2
AEMCLAP Accreditations PLANNED FOR 2006 Service Features • F ast report turn around - Raw data available within 24 hours of test completion. Report available in 48 hours. • Secure W ebsite - Clients will be provided with a secure Website where data and reports will be posted for their convenience. • Remote monitoring - We will provide a method of monitoring tests based on the clients needs: -VHS -DVD -Live Webcam EMC Testing • SAE J1113-4 Conducted Immunity (BCI) • SAE J1113-11 Immunity to Conducted Transients on Power Leads • SAE J1113-12 Electrical Interference by Conduction and Coupling • SAE J1113-13 Immunity to Electrostatic Discharge • SAE J1113-21 Immunity to Electromagnetic Fields (up to 8GHz) • SAE J1113-22 Immunity to Radiated Magnetic Fields from Power Lines • SAE J1113-25 Immunity to Radiated Electromagnetic Fields - Tri-Plate Line Method • SAE J1113-27 Immunity to Radiated Electromagnetic Fields - Reverberation Method • SAE J1113-41 Test Limits and Methods of Measurement of Radio Disturbance Characteristics from Vehicle Components and Modules • SAE J1113-42 Conducted Transient Emissions • SAE J551 • GM, Ford, Daimler-Chrysler, Renault, Nissan, Mazda, Honda, Audi, Toyota, Jaso, BMW, VW, Hyundai, Fiat OEM Specific Requirements as well, including GMW3097 Feb04, Ford ES-XW-7T-1A278-AC, DC 10614, Renault/Nissan 36-00-808, Nissan 28400 NDS, Mazda MES PA 66920 • ISO 7637 Series (-1, 2, 3) Electrical disturbance by conduction and coupling • ISO 11452-4 Bulk Current Injection (BCI) • ISO 11452-2 Radiated RF Immunity (ALSE) • ISO 10605 Electrostatic Discharge (ESD) • European Directive 2004/104/EC Emissions Tests • Radiated Emissions • CISPR 25, Nissan, Ford, ISO, SAE, Fiat, Audi, GM, Chrysler, Honda and many others • Use R+S Receiver ESIB 26.5 with low loss cables • AEMCLAP Certified measurements in our 3m/CISPR25 Anechoic and CISPR25 Anechoic Chamber from 10 kHz to 26.5 GHz • Conductive / Non-conductive table top • AEMCLAP Certified Site • 8' diameter turntable capable of handling 2200 lbs. Max. Line Conducted Emissions • Horizontal and Vertical ground planes / 3m Chamber and CISPR25 Chambers Immunity Tests Electrostatic Discharge (ESD) • +/- 15 kV Contact Discharge, +/- 30 kV Air Discharge. • Humidity & Temperature controlled rooms and lab. • Waveform verification target with 2 GHz Oscilloscope. • Various ESD tips from standard IEC/EN test to tips designed for automotive including the necessary one to perform GMW3097 Feb04, Ford ES-XW-7T-1A278-AC and DC 10614 and many other ones. EMC, performance and vibration test capabilities and test equipment. Automotive Services Automotive Services EMC TESTING /服务特点 /2006年计划的 AEMCLAP 认可 / EMC 测试 /发射测试 /抗扰度测试

Automotive ServicesAutomotive Services EMC TESTING€¢ SAE J1113-25 Immunity to Radiated Electromagnetic Fields - Tri-Plate Line Method • SAE J1113-27 Immunity to Radiated Electromagnetic

  • Upload
    vanque

  • View
    218

  • Download
    0

Embed Size (px)

Citation preview

AEMCLAP Accreditations PLANNED FOR 2006

Service Features• Fast report turn around - Raw data available within 24 hours of test

completion. Report available in 48 hours.• Secure Website - Clients will be provided with a secure Website

where data and reports will be posted for their convenience.• Remote monitoring - We will provide a method of monitoring tests

based on the clients needs:-VHS-DVD-Live Webcam

EMC Testing• SAE J1113-4 Conducted Immunity (BCI)• SAE J1113-11 Immunity to Conducted Transients on Power Leads• SAE J1113-12 Electrical Interference by Conduction and Coupling• SAE J1113-13 Immunity to Electrostatic Discharge• SAE J1113-21 Immunity to Electromagnetic Fields (up to 8GHz)• SAE J1113-22 Immunity to Radiated Magnetic Fields from Power Lines• SAE J1113-25 Immunity to Radiated Electromagnetic Fields - Tri-Plate Line Method• SAE J1113-27 Immunity to Radiated Electromagnetic Fields - Reverberation Method• SAE J1113-41 Test Limits and Methods of Measurement of Radio Disturbance Characteristics from Vehicle

Components and Modules• SAE J1113-42 Conducted Transient Emissions• SAE J551• GM, Ford, Daimler-Chrysler, Renault, Nissan, Mazda, Honda, Audi, Toyota, Jaso, BMW, VW, Hyundai, Fiat

OEM Specific Requirements as well, including GMW3097 Feb04, Ford ES-XW-7T-1A278-AC, DC 10614,Renault/Nissan 36-00-808, Nissan 28400 NDS, Mazda MES PA 66920

• ISO 7637 Series (-1, 2, 3) Electrical disturbance by conduction and coupling• ISO 11452-4 Bulk Current Injection (BCI)• ISO 11452-2 Radiated RF Immunity (ALSE)• ISO 10605 Electrostatic Discharge (ESD)• European Directive 2004/104/EC

Emissions Tests• Radiated Emissions• CISPR 25, Nissan, Ford, ISO, SAE, Fiat, Audi, GM, Chrysler, Honda and many others• Use R+S Receiver ESIB 26.5 with low loss cables• AEMCLAP Certified measurements in our 3m/CISPR25 Anechoic and CISPR25 Anechoic Chamber

from 10 kHz to 26.5 GHz• Conductive / Non-conductive table top• AEMCLAP Certified Site• 8' diameter turntable capable of handling 2200 lbs. Max.

Line Conducted Emissions• Horizontal and Vertical ground planes / 3m Chamber and CISPR25

Chambers

Immunity TestsElectrostatic Discharge (ESD)• +/- 15 kV Contact Discharge, +/- 30 kV Air Discharge.• Humidity & Temperature controlled rooms and lab. • Waveform verification target with 2 GHz Oscilloscope. • Various ESD tips from standard IEC/EN test to tips designed for automotive including the necessary one

to perform GMW3097 Feb04, Ford ES-XW-7T-1A278-AC and DC 10614 and many other ones.

EMC, performance and vibration test capabilities and test equipment.

Automotive ServicesAutomotive Services EMC T E S T I NG

/服务特点

/2006年计划的AEMCLAP认可

/EMC 测试

/发射测试

/抗扰度测试

Bulk Current Injection (BCI)• Use of dual directional power meter and probes for Forward, Reverse and Net

power measurements for every test if necessary.• Fixtures specifically designed per standards to improve repeatability• Specific equipment per standard used for testing to ensure proper testing and

repeatability• Can perform testing to Ford, GM, Chrysler, Fiat, Nissan, Honda, Mazda, Audi,

ISO or any other BCI standard.• Ability to go up to 1GHz in frequency

Radiated Electromagnetic Fields (RF)• Tested in new 3m Anechoic chamber or new SMART 200 reverberation chamber• Uniform field per IEC/EN specification.• Variety of modulations (AM, FM, Pulsed)• Field strengths designed for >600 V/m at a distance of 1m CW or pulsed

from 1-8GHz• Calibrated fields available up to 8 GHz

- 1kW amplifier from 80 MHz- 1 GHz- 250W amplifiers from 1 GHz - 8 GHz

• Isolated shielded support room for clients support equipment• Separate shielded control room and isolated shielded amplifier room.• 8 foot by 8 foot door opening• Meets and exceeds requirements for 16 different standards.• CISPR 25 ground studs 90cm off floor• Air pressure @ 125PSI• 100V/m fiber optic CCTV (Have access to viewing the product with a fiber optic

camera system that shows no effect due to the high field strength produced) • Fiber optically controlled mast and turntable• Automated Radiated Immunity and Radiated Emissions testing capability

Available power• up to 380V AC @ 150 Amps (50Hz or 60Hz single or three phase)• up to 65V DC @ 150 AmpsEach power line is independently filtered.

CISPR25 EMC Chamber Specifications• Certified from 10 kHz - 18GHz• Radiated Emissions capable of 2m up to 26.5GHz measurements• Radiated Immunity from 80MHz - 8GHz @ 200 V/m CW• Radiated Immunity from 1.2GHz - 1.4GHz @ 600 V/m CW or pulsed• Radiated Immunity from 2.7GHz - 3.1GHz @ 600 V/m CW or pulsed• Calibrated Uniform field all 16 points from 26MHz - 8GHz• Interior working dimensions of 20 feet x 20 feet x 12 feet• Shielding performance greater than 100dB from 1kHz - 18GHz• Isolated shielded support room for clients support equipment• Separate shielded control room and isolated shielded amplifier room.• 8 foot by 8 foot door opening• Meets and exceeds requirements for 16 different standards.• CISPR 25 ground studs 90cm off floor• 100V/m fiber optic CCTV (Have access to viewing the product with a fiber optic

camera system that shows no effect due to the high field strength produced) • Automated Radiated Immunity and Radiated Emissions testing capability

Available power• up to 380V AC @ 150 Amps (50Hz or 60Hz single or three phase)• up to 65V DC @ 150 AmpsEach power line is independently filtered.

SMART 200 EMC Chamber Specifications• Certified from 10 kHz - 18GHz• Radiated Immunity from 80MHz - 8GHz @ 200 V/m CW• Radiated Immunity from 1.2GHz - 1.4GHz @ 600 V/m CW or pulsed• Radiated Immunity from 2.7GHz - 3.1GHz @ 600 V/m CW or pulsed• Calibrated Uniform field all 16 points from 26MHz - 8GHz• Radiated Emissions capable of 1m up to 18GHz measurements• Interior working dimensions of 15.5 feet x 11 feet x 10 feet• Shielding performance greater than 100dB from 1kHz - 18GHz• Isolated shielded support room for clients support equipment• 7 foot by 4 foot door opening• CISPR 25 ground studs 90cm off floor• 100V/m fiber optic CCTV (Have access to viewing the product with a fiber optic

camera system that shows no effect due to the high field strength produced) • Automated Radiated Immunity and Radiated Emissions testing capability

Available power• up to 380V AC @ 150 Amps (50Hz or 60Hz single or three phase)• up to 65V DC @ 150 AmpsEach power line is independently filtered.

FCC Testing

CE Testing IEC/EN 61000

• 3M Anechoic EMC Chamber- Capabilities from 26 MHz to 8GHz. Can be usedfor testing in accordance to: SAE, ISO, GM, Ford, Chrysler, Nissan, Audi, Fiat,Honda, Mazda, CISPR 25,11,16,22, SAE J1113, SAE J551 and many other ones.

• Typical industry standards include Automotive, GM 3097, 3100, DC 10614, FordAB/AC, Nissan, Mazda, Fiat, Honda, Audi, Chrysler, SAE, ISO, Mazda

• Peripheral support utilities are available: Compressed air (125 PSI @ 30 CFM,oiled or purified @ 2 Microns), External gas venting (200 CFM), AC Power up to 380 VAC @ 50 Amps (50 or 60 Hz) single or three phase, DC Power up to 65 VDC @ 150 Amps. Full color internal monitoring system, with multiple camera angles provided. Generators, Chillers, Power Loads, Inert Gases, EMC hardened computers, can be made available.

• EUT (equipment under test) can be either tabletop or floor standing equipment.• SMART 200 reverberation Chamber- Capabilities from 26 MHz to 8GHz.

Can be used for testing in accordance to any standard that considers mode stirring or mode tuning as acceptable test methods including GMW3097 Feb04,Ford ES-XW-7T-1A278-AC, SAE J1113-27 and other ones.

Conducted Transients Immunity• Tested with new Schaffner 5500 system.• Pulses verifications included before each test.• Able to perform the latest Ford ES-XW-7T-1A278-AC CI220 pulses A,B and C

using the Schaffner 5500 system.• Able to perform the latest Ford ES-XW-7T-1A278-AC CI260 pulse F using the

Schaffner 5500 system.• Able to perform the latest Ford ES-XW-7T-1A278-AC CI230 pulses with no

current limitation using the Schaffner 5500 system applying the 4 power cyclingwaveforms simultaneously if necessary.

• Can perform testing to Ford, GM, Chrysler, Fiat, Nissan, Honda, Mazda, Audi,ISO and many other standards.

3m/CISPR25 EMC Chamber Specifications• Certified from 10 kHz - 18GHz• Radiated Immunity from 80MHz - 8GHz @ 200 V/m CW• Radiated Immunity from 1.2GHz - 1.4GHz @ 600 V/m CW or pulsed• Radiated Immunity from 2.7GHz - 3.1GHz @ 600 V/m CW or pulsed• Calibrated Uniform field all 16 points from 26MHz - 8GHz• Radiated Emissions capable of 3m up to 18GHz measurements• Interior working dimensions of 26 feet x 20 feet x 18 feet• Shielding performance greater than 100dB from 1kHz - 18GHz• 2m diameter turntable rated for 2200 lbs

Building T52-8, No. 1201 Gui Qiao Road, Shanghai, China 201206 Ph: 86 21 5031 9089 Fax: +86 21 5899 6319

©2005 Intertek ETL Entelaw w w. i n t e r t e k - a u t o m o t i v e . c o m

Frequency Ranges Field Strength V/m Antenna

80 MHz to 2 GHz >200 Bi Log @ 1m distance

200 MHz to 18 GHz >200 Horn @ 1m distance

1.2 GHz to 1.4 GHz >600 High Gain Horn @ 1m distance