AUTOMATIC POWER FACTOR CONTROLLERS

AUTOMATIC POWER FACTOR CONTROLLERS

  • Upload
    michi

  • View
    88

  • Download
    8

Embed Size (px)

DESCRIPTION

AUTOMATIC POWER FACTOR CONTROLLERS. AUTOMATIC POWER FACTOR CONTROLLERS. DCRL3 - 3 BUILT-IN STEPS DCRL5 - 5 BUILT-IN STEPS ICON LCD WITH BACKLIGHT Alarm messages in 6 languages OPTICAL PORT ON FRONT EXPANDIBILITY WITH EXP… MODULES RS232, RS485, USB communications interface Additional steps - PowerPoint PPT Presentation

Citation preview

Diapositiva 1

AUTOMATIC POWER FACTOR CONTROLLERS

1AUTOMATIC POWER FACTOR CONTROLLERS

DCRL3 - 3 BUILT-IN STEPSDCRL5 - 5 BUILT-IN STEPS

ICON LCD WITH BACKLIGHTAlarm messages in 6 languagesOPTICAL PORT ON FRONTEXPANDIBILITY WITH EXP MODULESRS232, RS485, USB communications interfaceAdditional stepsDigital outputsHigh accuracy TRMS measurementsWide selection of electrical measures, including voltage and current THD with harmonic analysis up to 15th order.Wide power supply range (100-440VAC)Voltage input separated from power supply, suitable for VT connection in medium-voltage applications.2M60GB200114

2BACKLIGHT ICON LCDAUTOMATIC POWER FACTOR CONTROLLERSHelpful in bad lighting conditions

Main measurements regarding power factor correction viewed

The user can select the default measurement to display

With rotation mode activated all the measurements rotate automatically every 5 seconds on the display

Possibility to signal the alarm with backlight flashing.

In presence of alarm, a scrolling text appears on the display in 6 selectable languages.

3M60GB200114

Output statusCooling fan statusSecondary displayActive alarmAutomatic modeManual modeMain displayInductive / capacitiveBar graphAlphanumeric display

Step statusBACKLIGHT ICON LCDAUTOMATIC POWER FACTOR CONTROLLERS4M60GB200114

The bar-graph can be programmed with three different viewings:kvar ins/tot: amount of kvar actually inserted, with reference to the total reactive power installed in the panelCurr act/nom: Percentage of actual plant current with reference to the maximum current of the CTDelta kvar: Bar graph with center zero. It represents the positive/negative delta-kvar needed to reach the setpoint, compared to the total kvar installed.AUTOMATIC POWER FACTOR CONTROLLERS

The icons on the right side of the display indicate the step status:The controller displays the imminent connection or disconnection of the steps by their identification number (left) flashing The flashing can last for some time in cases in which the insertion of a step is not possible due to the reconnection time (discharge time of the capacitor).

When an alarm is generated, the display will show an alarm icon, the code and the description of the alarm in the language selected.5M60GB200114BACKLIGHT ICON LCD SCREEN

5AUTOMATIC POWER FACTOR CONTROLLERS

6BACKLIGHT ICON LCDBar graphParametersSetup menu

MeasurementsM60GB200114

AUTOMATIC POWER FACTOR CONTROLLERS

OPTICAL PORT ON FRONTAdvantagesNo need to disconnect the panel power supply to connect with the device

Electrical safety (no physical connection)

Easy access to the unit from the front.

CX01 IR to USB converterCX02 - IR to Wi-Fi dongle7M60GB200114

CX01CX02

AUTOMATIC POWER FACTOR CONTROLLERSUsing CX02 (WiFi), the following is possible:Project upload/download Controller cloning.PC link through USB (CX01) or WiFi (CX02) for:ProgrammingDiagnosticsData downloadingFirmware upgrade.OPTICAL PORT ON FRONT8M60GB200114

AUTOMATIC POWER FACTOR CONTROLLERSDIMENSIONSFront panel: 96x96mmDepth: 65mm (with or without modules).

9M60GB200114

9

AUTOMATIC POWER FACTOR CONTROLLERSEXPANSION MODULESPlug-in connection at the back of the base unitPower supplied by the base unitIncrease the number of outputs Add communication features.Additional stepsEXP10 06: 2 415 VAC 1,5A relaysNO and COM contacts for each output.Digital output modulesEXP10 03: 2 250VAC 5A relaysNC, NO and COM contacts for each output.Communication modulesEXP1010 Opto-isolated USB interface EXP1011 Opto-isolated RS232 interfaceEXP1012 Opto-isolated RS485 interface.

10M60GB200114

AUTOMATIC POWER FACTOR CONTROLLERStool-less installationFixing clips

11M60GB200114

AUTOMATIC POWER FACTOR CONTROLLERS

EXP 8000 Removable plastic accessory for labellingtool-less installation12M60GB200114

12AUTOMATIC POWER FACTOR CONTROLLERSMAIN CHARACTERISTICSAuxiliary power supplyRated voltage: 100440VAC.Voltage inputs2 inputs (L1, L2)Voltage range: 85720VAC (L-L).Voltage and current harmonic analysisTHDVTHDIApprovals and compliance IEC/EN 61010-1, IEC/EN 61000-6-2 IEC/ EN 61000-6-3UL508 and CSA C22.2 n14cULus pendingEACCurrent inputs1 inputCT secondary rated current: /5A or /1A (selectable)Current range: 125mA6A (/5A), 25mA1.2A (/1A)Output relays4 N/O + 1 C/O = 5 relays (expandable up to 7 with EXP1006)2 N/O + 1 C/O = 3 relays (expandable up to 5 with EXP1006).

13M60GB200114

AUTOMATIC POWER FACTOR CONTROLLERSSELLING POINTSUser InterfaceBacklight icon display with more informationExcellent legibility on bad light conditionBacklight flashing in case of alarmViewing of texts, measurements, and alarms in 6 languages (English, Italian, French, Spanish, Portuguese, German)Programmable bar graphs programmable.InstallationWide voltage range (85720VAC) in compact sizeThe installation depth does not change with the EXP expansion installedInstallation without toolsSimple programming from front panel.14M60GB200114

AUTOMATIC POWER FACTOR CONTROLLERSSELLING POINTSApplicationSingle-phase and three-phase installationCogenerating systems with dedicated setpointMedium voltage application with voltage transformers (VT)Measurement viewing relevant VT primaryDevice settings considering the primary side of the VTs (i.e. capacitor bank reactive power, protections, etc.)2-level password to protect functions and parameter setupReduced number of switchings by algorithmEqual usage of steps with the same reactive powerTHDV, THDI measurement and harmonic analysis up to 15th orderAdvanced protection for capacitor banks.15M60GB200114

SELLING POINTSExpandabilityBasic controller functionality can be easily extended using EXP series expansion modulesIncrease number of stepsAdding communication features.

Optical communication portStandard USB or Wi-Fi pointCommunication with PC, smartphone, and tablet to carry out programming, diagnostics and data download without removing power to the electric panel.AUTOMATIC POWER FACTOR CONTROLLERS16M60GB200114

DCRL vs DCRKDCRK5DCRK5 240DCRK5 440DCRK5 480DCRK5 525DCRK7DCRK7 240DCRK7 440DCRK7 480DCRK7 525DCRL5DCRL5 +EXP1006CT secondary/5A or /1A without special code managementDCRK3DCRK3 240DCRK3 440DCRK3 480DCRK3 525DCRL3AUTOMATIC POWER FACTOR CONTROLLERS17M60GB200114

Measures AvailableDCRL3/5DCRK3/5/7Cos Instantaneous power factorAverage weekly power factorVoltage and currentVoltage and current MaxElectric panel temperatureMax electric panel temperature Reactive power to reach set-pointTotal reactive powerCapacitor overloadMax capacitor overloadActive and apparent power-Current and voltage harmonic analysis-THD capacitor current-THDV, THDI-var-measured value per step-Number of switchings per step-Connection time insertion per step-AUTOMATIC POWER FACTOR CONTROLLERSProtectionsDCRL3/5DCRK3/5/7Over voltageUnder voltageOver currentOver compensationUnder compensationCapacitor overloadOver temperatureMains micro-breakingsProgrammable alarm propertyCapacitor bank failure-THDV max-THDI max-Protection password-Maintenance request-DCRL vs DCRK18M60GB200114

AUTOMATIC POWER FACTOR CONTROLLERSNEW MEASUREMENTS AND PROTECTIONSActive and apparent power Current and voltage harmonics analysisTHD capacitor currentTHDV,THDIWith the addition of these measurements and the alarms regarding THD max (voltage and current), the user can completely know the status of the systemThis information can be helpful for advanced analysis in case of system anomalies to introduce the necessary corrections.var-measured value per stepNumber of switchings per stepConnection time per stepThese measurements and the relative alarms, maintenance request and capacitor bank failure provide useful information for the power factor correction system supervisionThis information can be used to schedule the maintenance of the installations.19M60GB200114

DCRL3/DCRL5DCRG8User InterfaceDisplay typeBacklight icon LCDLCD graphic 128x80 pixel with backlightKeys45LEDs-1 alarm ledInputVoltage2 ph3 ph+NCurrent1ph3 or 1phCT secondary/5A or /1A/5A or /1A4 quadrant operationLV and MV applicationsStepsNumber of steps (relay)3 or 5 base unit5 or 7 with EXP10068 base unit10, 12, 14, 16 (with EXP)Fast steps compatibility (transistor)- (with EXP1001)Mixed transistor and relay configurations-8 + 8Other functionsBuilt-in temperature sensorInput for ext. temperature sensor-with EXPEvent logging-Master-Slave function-Customisable internal variables-Limit thresholdsRemote-controlled variablesUser alarmsEnergy consumption pulsesCountersDCRL vs DCRG8AUTOMATIC POWER FACTOR CONTROLLERSDCRL3/DCRL5DCRG8Setpointcos 3 set point Generating cos tan -HousingDimensions96x96x65 mm144x144x44 mm (73mm with EXP)IP protection degreeIP54IP54 (IP65 optional)Operating temperature-20...+60C -3070CStorage temperature-30...+80C-3080CEXP compatibilityCommunication interfaceEXP1010 - USBEXP1011 - RS232EXP1012 - RS485 EXP1013 - Ethernet -EXP1014 - Profibus DP-EXP1015 - GPRS/GSM modem-Additional stepsEXP1006 2 relays stepsEXP1001 4 static steps-Digital I/OsEXP1003 2 relays with 1 C/O eachEXP1000 4 inputs-EXP1002 2 inputs + 2 static outputs-Analog I/OsEXP1004 2 analog inputs-EXP1005 2 analog outputs-EXP1016 Capacitor harmonic protection-20M60GB200114

AUTOMATIC POWER FACTOR CONTROLLERSSETUP SOFTWARE DCRJ SW

You can use the DCRJ Remote control software to transfer set-up parameters from the DCRL to the hard drive of the PC and vice versa and read the measurements.21M60GB200114

AUTOMATIC POWER FACTOR CONTROLLERSWeb basedServer Multiclient structureOne software for many devices (multichannel)SUPERVISION AND CONTROL SOFTWARESynergy is a supervision and control software for:Electrical parameters (from voltage and current to energy)Environmental and process parameters (temperature, pressure, flux).Beyond providing data in tables and graphic pages, it offers:alarm generationchart plottingcommand sending to devices.22M60GB200114

AUTOMATIC POWER FACTOR CONTROLLERSAPPLICATIONS FOR SMARTPHONES AND TABLETSLovato applications let the user:Set up the deviceSend commands to the deviceRead valuesDownload statistics and eventsSend the retrieved data by e-mail.Wi-Fi connection between the smartphone/tablet and CX02The user is guided to be connected to the deviceAutomatic application upgrade if an Internet connection is availableCompatible with iOS and Android.23M60GB200114

AUTOMATIC POWER FACTOR CONTROLLERS

Thanks for your attention!www.LovatoElectric.com