ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 1 of 49
AHMEDABAD
ELECTRICAL RESEARCH &DEVELOPMENT ASSOCIATION
VADODARA, INDIA
AUTOMATED REPORTS GENERATION SYSTEM
FOR HIGH VOLTAGE TESTING DIVISION
SOFTWARE DESIGN DOCUMENT
HCCT-SDD-1120, Revision 0
Approval Signatures
AUTHOR: Atul Shah ____(Name) (Signature) DateApplitech Infotech
REVIEWED BY: Shalin Patel ____(Name) (Signature) Date
Applitech Infotech
APPROVED BY: R. B. Desai ____(Name) (Signature) Date
ERDA
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
2/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 2 of 49
Revision Log
Description ofRevision
Author Revision Number RevisionDate
Issued For Review Atul Shah 0 11/20/09
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
3/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 3 of 49
Table of Contents
1
AHMEDABAD............................................................................................................1
ELECTRICAL RESEARCH & DEVELOPMENT ASSOCIATION....................1
VADODARA, INDIA..................................................................................................1
AUTOMATED REPORTS GENERATION SYSTEM FOR HIGH VOLTAGE
TESTING DIVISION..................................................................................................1
SOFTWARE DESIGN DOCUMENT.......................................................................1
HCCT-SDD-1120, Revision 0.....................................................................................1Approval Signatures...................................................................................................1
Revision Log.................................................................................................................2
Table of Contents........................................................................................................3
1. Introduction ..............................................................................................................4
2. System Overview ......................................................................................................4
2.1 System Login Module ....................................................................................................4
2.2 Administration Module................................................................................................. 5
2.2.1 Customer Information............................................................................................... 5
To modify the customer details system provides a view with the searching facility is
shown below. On selection of any item above interface available with existing details to
the user.................................................................................................................................... 6
6
2.2.2 User Information ........................................................................................................6
To modify as well as assign the access privileges to the administrator system provides
a view with the searching facility is shown below. On selection of any item above
interface available with the existing details to the user........................................................ 8
82.2.3 Parameter Value .......................................................................................................10
2.2.4 Core Specification .....................................................................................................12
2.2.5 Backup .......................................................................................................................14
2.3 Report Creation Module .............................................................................................16
2.3.1 Current Transformer Testing .................................................................................16
2.3.2 CT-PT Testing ..........................................................................................................29
2.3.3 Potential Transformer Testing(PT Testing) ...........................................................40
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
4/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 4 of 49
1. IntroductionElectrical Research and Development Association (ERDA) is engaged in testing
activities of various kinds of transformers. ERDA performs no of testing like High
Voltage, Shot Circuit, Di-electrical, Meter Error Reading and others.
To reducing the time and eliminating the errors in a report generation process,
Applitech Infotech has developed the automated reports generation system for High
Voltage Testing Division. To capturing a automatic data in a testing accuracy class
system provides the online solution by integrating with excel files.
This document describes the specifications and features of our application software.
Also shall apply to implement the automated report generation system with in thedepartment or an organization.
2. System Overview
2.1 System Login ModuleThe user logs onto the computer terminal using the windows login information
provided to the user. After logging onto the terminal, he/she will open the web
browser and go to the login page of Automated Report Generation System.
The user will enter the username and password information in the login window of an
application home page. The user will only have access to screens for the systemdepending on the users access rights. Admin users will have access to all screens. A
screen shot of the application login page is shown below:
After successful login by the user, based on the access previllages, a Menu pageavailable to the user.
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
5/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 5 of 49
2.2 Administration Module.2.2.1
Customer Information.The interface for entering the customer information is shown below:
The following table provides the details on each field shown on the screen above.
Field Name Description Mandatory/Optional Values Comments
Name Enter the unique
Name of
Customer
Mandatory User defined Non Editable
in
Modification
Billing Address Enter the
address of a
customer to print
on invoice
Mandatory User defined
Communication
Address
Enter the
address of acustomer to
communicate
Optional User defined
Reporting
Address
Enter the
address of a
report sent to
Optional User defined
Email Enter the mail
address to
communicate
with the
customer
Optional User defined
Phone No Enter the contact
details of a
customer
Optional User defined
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
6/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 6 of 49
Fax Enter the Fax
No
Optional User defined
To modify the customer details system provides a view with the searching facility is
shown below. On selection of any item above interface available with existing details
to the user.
2.2.2 User InformationThe interface for entering the user information is shown below:
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
7/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 7 of 49
The following table provides the details on each field shown on the screen above.
Field Name Description Mandatory/Optional Values Comments
User Name Enter the unique
name of a user
Mandatory User defined Not Editable
in
Modification
Designation Enter the
designation
Mandatory User defined
Type of User Select from the
list
Mandatory Select from
Administrative,
Normal
For
Administrative
user select the
administrative
while for
others selectNormal
Login ID Enter the unique
Login ID name
Mandatory User defined Not Editable
in
Modification
Password Enter the
password
Mandatory User defined Min length 6
digit; Not
Editable in
Modification
Email ID Enter the mail
address of a user
Mandatory User defined
Securityquestion Select thesecurity
question
Mandatory Select from thelist. Values in aselection list
available from
parameter
value under
type security
question.
Your Answer Enter the answer
for selected
security
question
Mandatory User defined
Status For valid user
select Activewhile for not
valid select
Inactive
Optional Select from the
List
Default it
stores Active
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
8/49
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
9/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 9 of 49
User can change his/her password by logged into the account by default password. On
click of Change Password following screen is available to the user.
In case of forgot password, system provides the forgot password option to user while
logged in. On click of forgot password following interface avaialble to the user anduser has to submit the correct answer of a security question. If answer is correct,
system generates a new password and auto mail to users mail ID with the password
information.
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
10/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 10 of 49
2.2.3 Parameter ValueSystem provides the number of default parameter types to the user for configuring therequired values. At the time of transactions selection of these values available to user
according to the parameter. Default list of a Parameters type is given below.
No Type Description Remarks
01 Class Under the type user can able to create the different
class values.
02 Ratio CT Under the type user can able to create the different
ratio related to Current Transformer Testing.
03 Security Question Under the type user can able to create the different
security questions for users security.04 Burden % Only system administrator can able to create the
different values for Burden %.
05 Current Rated % Only system administrator can able to create the
different values for Current Rated %.
06 Connected to gather to
earth
Under the type user can able to create the different
values related to power frequency dry withstand test
on primary winding.
07 NSV Under the type user can able to create the different
NSV values along with IL and HSV.
08 Enable Capture Default value is Y. For manual entries in a Testing
accuracy class modify and set the value to N09 Ratio CTPT Under the type user can able to create the different
ratio related to CTPT and Potential Transformer
Testing.
10 Phase Pattern Under the type user can able to create the different
Phase Pattern used in CTPT report for secondary
winding terminals.
11 Current Report Start According to the requirement user can set the start
date of a year to control the duplication into report
no.
12 Previous Report Start According to the requirement and allow to backdate
entries user can set the start date of a previous year to
control the duplication into report no.
13 Frequency Voltage % Under the type user can able to create different
frequency Voltage % according to the requirement in
dry withstand test on secondary winding and on
primary winding.
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
11/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 11 of 49
A screen shot of the parameter value screen is shown below:
The following table provides the details on each field shown on the screen above.
Field Name Description Mandatory/Optional Values CommentsParameter
Type
Select the
parameter
type.
Mandatory From the
Parameter
Type Master
Non editable
in
modification
Parameter
Value
Enter the
unique value
with in a type
Mandatory User defined Non editable
in
modification
Status Select Active
for valid
while
Inactive for
not valid
Mandatory Select from
the list
To change the status of a parameter value following view available to the user. On
click of any item interface with the values available to the user.
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
12/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 12 of 49
2.2.4 Core Specification
One or more cores are available on Current transformer and Voltage transformer
available with the specific values of a current or a voltage. Per CT, CTPT and PT
testing, according to the requirement user need to configure the core specification ifnot exist into a standard list of core specification. User can able to configure the core
specification of a Current transformer under CT Type wile for CTPT & PT type
CTPT available to the user. The interface for entering the core specification is shown
below:
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
13/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 13 of 49
The following table provides the details on each field shown on the screen above.
Field Name Description Mandatory/Optional Values Comments
Unit Type Select the Unit type from
the list
Mandatory Select CT
for
Current
Transfor
mer
while
CTPT for
CTPT
testing as
well asPT
Testing
Non editable
in
modification
Core Sr No. Enter the Sr. No of a unit Mandatory Non editable
in
modification
Core Enter the standard
current applied to a core
Mandatory Non editable
in
modification
Burden(VA) Enter the standard
burden applied to the unit
Mandatory Non editable
in
modification
Limit Class Select from the list Mandatory From The
Paramete
r Value
Master
under the
type
Class
Non editable
in
modification
ISF/ALF Enter the standard value
of ISF
Optional Non editable
in
modificationCore
Specification
(Core No-
Core(A)/Bur
den/Class)
System generates auto Auto From the
available
values
Non editable
in
modification
Status Select Active for valid
while InActive for not
valid
Mandatory Select
from the
list
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
14/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 14 of 49
To change the status of a core specification following view available to the user. On
click of any item interface with the values available to the user.
2.2.5 BackupSystem provides the Backup option to administrator for taking a backup of a data. To
get the successful backup administrator has to ensure that none of user logged into the
system i.e. system should in exclusive mode.
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
15/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 15 of 49
On completion of a backup user will get the following screen.
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
16/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 16 of 49
2.3 Report Creation Module2.3.1 Current Transformer Testing
A screen shot of the parameter value screen is shown below:
The following table provides the details on each field shown on the screen above.
HEADER INFORMATION
Field Name Description Mandatory/Opt
ional
Values Comments
Name Select thecustomer
name
Mandatory From theCustomer
information
Address System
display
automatically
Auto From the
Customer
Information
Not Editable
in Add/Modify
Customer Ref Date Enter the
customer
reference
date
Mandatory User defined Date format:
DD.MM.YYY
Y
Customer Ref No Enter the
customerreference No
Mandatory User defined Duplication
controls onCustomer Ref
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
17/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 17 of 49
Date and
Customer Ref
NoSHS Date Enter the
SHS Date
Optional User defined Date format:
DD.MM.YYY
Y
SHS No Enter the
SHS No
Optional User defined If SHS date
and SHS No
available then
system check
the duplication
on SHS Date
and SHS No
Gate Inward Date Enter theGate Inward
Date
Optional User Defined Date format:DD.MM.YYY
Y
Gate Inward No Enter the
Gate Inward
No
Optional User defined If GI date and
GI No
available then
system check
the duplication
on GI Date
and GI No
Work Order Date Enter the
Work Order
Date
Optional User defined Date format:
DD.MM.YYY
Y
Work Order No Enter the
Work order
no
Optional User defined If WO date
and WO No
available then
system check
the duplication
on WO Date
and WO No.
Also if WO
detailsavailable then
only user can
able to select
the test details.
Date of Sample
Receipt
Enter the
Date of
Sample
receipt
Optional User defined Date format:
DD.MM.YYY
Y
Date of Testing Enter the
date of
testing
Optional User defined Date format:
DD.MM.YYY
YTest Report Date Enter the Optional User defined Date format:
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
18/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 18 of 49
Test Report
Date
DD.MM.YYY
Y
Test Report No Enter theTest report
No
Optional User defined If TR date andTR No
available then
system check
the duplication
on TR Date
and TR No.
Also system
not allows the
report entry if
TR dates less
than parametervalue previous
report starts
date.
Tested By Select from
the list
Optional From User
Master
Checked By Select User
from List
Optional From User
Master
Value assign
from Report
approval by
authorized
user.
MFD.BY Enter the
name of
client
Optional User defined
No of Core Enter the no
of core
required
Mandatory User defined Numerical
value are only
allow
Ratio Select the
ratio from
the list
Mandatory From Parameter
value Master
under the type
Ratio
User can able
to select
multiple Ratio
Core Specification Select theCore
Specification
from the list
Mandatory From Corespecification
under the Unit
Type CT
Systemautomatically
check the No
of Core is
equal to select
the Core
Specification
NSV Select the
NSV
Mandatory From Parameter
Value Master
under the unit
type CT
I.L Systemautomatically
Auto From Parameter Value Master
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
19/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 19 of 49
display the
value
HSV Systemautomatically
display the
value
Auto From Parameter Value Master
S.T Current(kA) Enter the
value of
Standard
Transformer
Current
Optional User defined
Frequency Enter the
frequency of
the currenttransformer
testing
Mandatory User defined
v.k(min) Enter the v.k
for the
current
transformer
Optional User defined
IEX(min)@VK Enter the
IEX in
minute and
VK value
Optional User defined
RCT(max)@75C Enter the
RCT Value
Optional User defined
INS.Class Enter the
Insulation
Class Value
for the
Current
Transformer
Testing
Optional User defined
Model Enter the
Model Name
Optional User defined
Sr. No Enter the
Serial No of
the Sample
Mandatory User defined
Type Enter the
Type of
Sample
Mandatory User defined
Drawing No Enter the
Drawing No
of Sample
Optional User defined
ERDA
Identification No
Enter the
ERDAIdentification
Mandatory User defined
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
20/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 20 of 49
No
Remark Enter the
remarks ifany
Optional User defined
Test Details Select the
required test
to be perform
on the
Current
Transformer
Optional From Test
Detail Master
under type CT
Work order
date and Work
order no must
be entered
Result Select the
result on
completion
of allselected tests
Optional 1. Confirm
2. Not
confirm
3. Resultas per
Remarks
4. Under
Testing
While adding
new test result
will be 4
defaults.Section will be
shown to the
user if all tests
data are
available into
the system.
Remark For result as
per remarks
selected,
Enter the
Test Result if
any
Optional User defined Section will be
shown to the
user if all tests
data are
available into
the system.
Note Please enter
the general
notes if any
Optional User defined Section will be
shown to the
user if all tests
data are
available into
the system.
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
21/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 21 of 49
TEST DETAILS
TEST NAME: TERMINAL MARKING AND POLARITY.
The user interface for the Terminal Marking and Polarity Test is shown below.
The following table provides the details on each field shown on the screen above.
Field Name Description Mandatory/Optiona
l
Values Comments
Primary Winding
Terminals
Enter the
value of the
primary
winding
value for theSample
Mandatory User
defined
Secondary
Winding
Terminals
System
generates
default
details
based on
the no of
core and
Ratio
selected
Mandatory User
defined
User can
change if
any
Terminal markingand polarity found
Select theTerminal
Mandatory 1.O.K 2.Not O.k.
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
22/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 22 of 49
marking and
Polarity
found value
TEST NAME: DETERMINATION OF ERRORS ACCORDING TO THE
REQUIREMENTS OF APPROPRIATE ACCURACY CLASS.
The user interface for the testing Accuracy Test is shown below. To capturing a
automatic data in a testing accuracy class click on capture button, Applitech Infotech
has provided the online solution by integrating with excel files. To enter the manual
entry user has to set the Capture from parameter value from Y to N.
The following table provides the details on each field shown on the screen above.
Field Name Description Mandatory/Optional Values Comments
Ratio Select the
Ratio from
the list
Mandatory From
Header
Details
CoreSpecification Select theCore Mandatory FromHeader
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
23/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 23 of 49
Specification
from the list
Details
Burden (%) Select theBurden (%)
Mandatory FromParameter
Value under
type Burden
(%)
Current Rated
(%)
Select the
Current Rated
(%)
Mandatory From
Parameter
Value under
type
Current
Rated (%)
Phase AngleError(Min)
Enter thePhase Angle
Error
Mandatory User Define
Ratio Error
(%)
Enter the
Ratio Error
(%)
Mandatory User Define
Accuracy
Class
Enter the
Accuracy
Class
Mandatory User Define System Check
All Row are
unique on
Ratio, Core
Specification,
Applied
Burden and
Current Rated
%
TEST NAME: POWER FREQUENCY DRY WITHSTAND TEST ON
PRIMARY WINDING.
The user interface for the primary winding Test is shown below.
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
24/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 24 of 49
Field Name Description Mandatory/Optio
nal
Values Comment
Power
Frequency
Voltage(kv)
System
generates
default details
based on the no
HSV entered.
Also select the
power
frequency
voltage % from
list available
Mandatory Frequency
voltage % from
parameter value
master under the
type Frequency
Voltage.
ConnectedTo Earth
Select one ormore value
from the list
Mandatory FromParameterValue
under the tyoe
Connected to
earth
Duration Enter the
Duration and
select Minute or
Second from the
list
Mandatory User Defined
TEST NAME: POWER FREQUENCY DRY WITHSTAND TEST ON
SECONDARY WINDING.
The interface for Power frequency dry withstand test on secondary winding test is
shown below.
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
25/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 25 of 49
Field Name Description Mandatory/Option
al
Values Comment
PowerFrequency
Voltage(KV)
Enter the PowerFrequency
Voltage(KV) and
select power
frequency
voltage %
Mandatory User Defined
Defaultvalue 3
Secondary
winding
terminals
System
automatic
generate
secondary
winding terminal
values based onthe No of Core
and Ratio
Selected in to the
Header details
Mandatory User defined
CT Result Enter the CT
result
Mandatory User
Defined
Default No
disruptive
and
withstood
TEST NAME: OVER VOLTAGE INTER- TURN TEST.
The interface for Over voltage inter turn test on secondary winding test is shown
below.
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
26/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 26 of 49
Field Name Description Mandatory/Optional Values Comment
SecondaryWinding
Terminal
Select fromthe list, also
select % value
Mandatory System autogenerates
the list
value based
on the No of
Core Header
details
% valuefrom the
Parameter
Master.
Rated
Secondary
Current(amp)
Enter the
Rated
Secondary
Current(amp)
Mandatory User Define
CT Result Enter the CTResult
Mandatory User Define
Duration Enter the
value of
Duration
Mandatory User Define Select
Minute or
Second from
the list
TEST NAME: INSTRUMENT SECURITY FACTOR TEST.
The interface of Instrument Security Factor Test is shown below.
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
27/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 27 of 49
Field Name Description Mandatory/Optional Values Comment
Ratio Select from
the list
Mandatory List value
based onthe Ratio
selected in
Header
Details
System
Check onlyOne Ratio
enter the
value
Core
Specification
Select from
the list
Mandatory List values
based on
the Selected
core with
the
specified
ISFavailable on
Header
Details
Core(A) System
Automatic
display from
the selected
core
Auto User
defined
Excitation
Current
System
Automatic
generated
based on
formula
Auto User
defined
Formula:
Cold
Resistance
(mOhms)
Enter the Cold
Resistance
Mandatory User Define
Ambient
Temperature
Enter the
Ambient
Temperature
Mandatory User Define
Voltage
Measured
Enter the
VoltageMeasured
Mandatory User Define
SLV System Auto
Generate SLV
value based
on fix
Formula
Auto Read only Formula:
Therefore ISF System Auto
Generate
Therefore ISF
value based
on fixFormula
Auto Read only Formula:
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
28/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 28 of 49
TEST NAME: MEASUREMENT OF PARTIAL DISCHARGE.
The interface of Partial Discharge Measurement is shown below.
Field Name Description Mandatory/Optional Values Comment
Pre-Stress
Voltage(Um)
Enter the Pre-
Stress
Voltage(Um)
Mandatory User
Define
System
automatically
display
default value
Duration(Sec) Enter the
Duration
with sign
Mandatory User
Define
System
automatically
display
default value
Reduce
Voltage(Um)
Enter the
Reduce
Voltage
Mandatory User
Define
System
automatically
display
default value
Duration
Maintained(Min)
Enter the
Duration
Maintained
with sign
Mandatory User
Define
System
automatically
display
default value
Magnitude
Voltage(pC)
Enter the
MagnitudeVoltage
Mandatory User
Define
System
automaticallydisplay
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
29/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 29 of 49
default value
Limit Of Pd
Quantity(pC)
Enter the
Limit if PDQuantity
Mandatory User
Define
System
automaticallydisplay
default value
2.3.2 CT-PT Testing
A screen shot of the CT-PT screen is shown below:
The following table provides the details on each field shown on the screen above.
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
30/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 30 of 49
HEADER INFORMATION
Field Name Description Mandatory/O
ptional
Values Comments
Name Select the
customer name
Mandatory From the
Customer
information
Address System display
automatically
Auto From the
Customer
Information
Not Editable
in Add/Modify
Customer Ref Date Enter the
customer
reference date
Mandatory User defined Date format:DD.MM.YYYY
Customer Ref No Enter the
customer
reference No
Mandatory User defined Duplication
controls on
Customer Ref
Date and
Customer Ref
No
SHS Date Enter the SHS
Date
Optional User defined Date format:DD.MM.YYYY
SHS No Enter the SHS
No
Optional User defined If SHS date
and SHS Noavailable then
system check
the duplication
on SHS Date
and SHS No
Gate Inward Date Enter the Gate
Inward Date
Optional User Defined Date format:
DD.MM.YYY
Y
Gate Inward No Enter the Gate
Inward No
Optional User defined If GI date and
GI No
available thensystem check
the duplication
on GI Date
and GI No
Work Order Date Enter the Work
Order Date
Optional User defined Date format:
DD.MM.YYY
Y
Work Order No Enter the Work
order no
Optional User defined If WO date
and WO No
available then
system checkthe duplication
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
31/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 31 of 49
on WO Date
and WO No.
Also if WOdetails
available then
only user can
able to select
the test details.
Date of Sample
Receipt
Enter the Date
of Sample
receipt
Optional User defined Date format:
DD.MM.YYY
Y
Date of Testing Enter the date
of testing
Optional User defined Date format:
DD.MM.YYY
YTest Report Date Enter the Test
Report Date
Optional User defined Date format:
DD.MM.YYY
Y
Test Report No Enter the Test
report No
Optional User defined If TR date and
TR No
available then
system check
the duplication
on TR Date
and TR No.
Also system
not allows the
report entry if
TR dates less
than parameter
value previous
report starts
date.
Tested By Select from the
list
Optional From User
Master
Created User
Show Here.
Checked By Select User from List
Optional From User Master
Value assignfrom Report
approval by
authorized
user.
Sample Name Enter the
Sample Name
Optional User defined
MFD.BY Enter the name
of client
Optional User defined
No of Core Enter the no of
core required
Mandatory User defined Numerical
value are only
allowRatio CT Select the ratio Mandatory From Parameter User can able
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
32/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 32 of 49
from the list value Master
under the type
Ratio and Unittype CT
to select
multiple Ratio
Ratio PT Select the ratio
from the list
Mandatory From Parameter
value Master
under the type
Ratio and Unit
type CTPT
User can able
to select
multiple Ratio
Core Specification Select the Core
Specification
from the list
Mandatory From Core
specification
under the Unit
Type CTPT
System
automatically
check the No
of Core is
equal to selectthe Core
Specification
No. Of CTS/PTS Enter the
number of CTS
and PTS
Optional User defined
Phase Select the
Phase
Optional From Parameter
Value Master
under the unit
type Phase
System
automatically
generate the
phase no
depends on
selection of
phase
Conn Enter the
Connection
value for the
PT
Optional User defined
NSV Select the NSV
from the list
Mandatory From Parameter
Value Master
under the unit
type CTPT
I.L Systemautomatically
display the
value
Auto From Parameter Value Master
Systemautomatically
generate Value
here But
Editable Field.
H.S.V System
automatically
display the
value
Auto From Parameter
Value Master
System
automatically
generate Value
here But
Editable Field.
Rated V Enter the Rated
Voltage for theSample
Optional User defined
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
33/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 33 of 49
S.T Current Enter the value
of Standard
CTPT
Optional User defined
V.F Enter the value
of Standard
CTPT
Optional User defined
Frequency Enter the
frequency of
the CTPT
testing
Mandatory User defined
Insulation. Class Enter the
Insulation
Class Value for
the CTPTTesting
Optional User defined
Sr. No Enter the Serial
No of the
Sample
Mandatory User defined
Type Enter the Type
of Sample
Mandatory User defined
Drawing No Enter the
Drawing No of
Sample
Optional User defined
ERDAIdentification No Enter theERDA
Identification
No
Mandatory User defined
Remark Enter the
remarks if any
Optional User defined
Test Details Select the
required test to
be perform on
the CTPT
Optional From Test
Detail Master
under type CT
PT
Work order
date and Work
order no must
be entered
Result Select the
result oncompletion of
all selected
tests
Optional 1. Confirm
2. Notconfirm
3. Result
as per
Remarks
4. Under
Testing
While adding
new test resultwill be 4
defaults.
Section will be
shown to the
user if all tests
data are
available into
the system.
Remark For result as
per remarks
selected, Enterthe Test Result
Optional User defined Section will be
shown to the
user if all testsdata are
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
34/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 34 of 49
if any available into
the system.
Note Please enter the general
notes if any
Optional User defined Section will beshown to the
user if all tests
data are
available into
the system.
TEST DETAILS
TEST NAME: VERIFICATION OF TERMINAL MARKING AND
POLARITY.
The user interface for the Terminal Marking & Polarity Test CTPT is shown below.
The following table provides the details on each field shown on the screen above.
Field Name Description Mandatory/Optional Values Comments
Primary Winding
Terminals CT
Enter the
Value of the
Primary
Winding CT
Value for
the Sample
Mandatory Auto/
User
defined
System auto
generate
value based
on Phase,
No of Core
and Core
Specificatio
nPrimary Winding Enter the Mandatory Auto/ System auto
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
35/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 35 of 49
Terminals PT Value of the
Primary
Winding PTValue for
the Sample
User
defined
generate
value based
on Phase, No of Core
and Core
Specificatio
n
Secondary
Winding
Terminals CT
Enter the
Value of the
Secondary
Winding CT
Value for
the Sample
Mandatory Auto/
User
defined
System
Automatic
generate
based on
the no of
core and
Ratioselected in
the header
details
Secondary
Winding
Terminals PT
Enter the
Value of the
Secondary
Winding PT
Value for
the Sample
Mandatory User
defined
System
Automatic
generate
based on
the no of
core and
Ratio
selected in
the header
details
Terminal marking
and polarity found
Select the
Terminal
marking and
Polarity
found value
from the list
Optional 1.O.K
2.Not O.k.
Value Select
From The
List.
TEST NAME: DETERMINATION OF ERROS ACCORDING TO THEREQUIREMENT OF THE APPROPRIATE ACCURACY CLASS.
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
36/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 36 of 49
The user interface for the testing Accuracy Test is shown below. To capturing
a automatic data in a testing accuracy class system, Applitech Infotech has providedthe online solution by integrating with excel files. To enter the manual entry user has
to set the Capture from parameter value from Enable Capture Y Or N.
Enable Capture Y = automatic data in a testing accuracy class system.
Enable Capture N= User defined.
The following table provides the details on each field shown on the screen above.
Field Name Description Mandatory/Optional Values Comments
Phase Select thePhase From
the list
Mandatory FromHeader
Details
System Autogenerate
based on
header details
Ratio Select the
Ratio from the
list
Mandatory From
Header
Details
Core
Specification
Select the
Core
Specification
from the list
Mandatory From
Header
Details
Burden (%) Select the
Burden (%)
Mandatory From
Parameter
Value under
type Burden
(%)
Current
Rated (%)
Select the
Current Rated
(%)
Mandatory From
Parameter
Value under
type Current
Rated (%)
Phase AngleError(Min)
Enter thePhase Angle
Mandatory User Define
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
37/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 37 of 49
Error
Ratio Error
(%)
Enter the
Ratio Error(%)
Mandatory User Define
Accuracy
Class
Enter the
Accuracy
Class
Mandatory User Define System Check
All Row are
unique on
Ratio, Core
Specification,
Applied
Burden and
Current Rated
%
TEST NAME: INSTRUMENT SECURITY FACTORTEST ON CTS.
The user interface for Instrument Security FactorTest CTPT shown below:
The following table provides the details on each field shown on the screen above.
Field Name Description Mandatory/Optional Values CommentRatio Select from
the list
Mandatory List value
based on
the Ratio
selected in
Header
Details
System
Check only
One Ratio
enter the
value
Core
Specification
Select from
the list
Mandatory List values
based on
the Selected
core with
thespecified
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
38/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 38 of 49
ISF
available on
HeaderDetails
Core(A) System
Automatic
display from
the selected
core
Auto Read only
Excitation
Current
System
Automatic
generated
based on
formula
Auto Auto /User
defined
Formula:
Cold
Resistance
(mOhms)
Enter the Cold
Resistance
Mandatory User Define
Ambient
Temperature
Enter the
Ambient
Temperature
Mandatory User Define
Voltage
Measured
Enter the
Voltage
Measured
Mandatory User Define
SLV System AutoGenerate SLV
value based
on fix
Formula
Auto Read only Formula:
Therefore ISF System Auto
Generate
Therefore ISF
value based
on fix
Formula
Auto Read only Formula:
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
39/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 39 of 49
TEST NAME: VISUAL EXAMINATION OF HOT DIP GALVANIZING.
The user interface for Visual examination of hot dip galvanizingshown below:
The following table provides the details on each field shown on the screen above.
Field Name Description Mandatory/Optional Values Comment
Requirement Enter the
Requirement
for the
Sample
Optional User defined
Observation Enter the
Observation
for theSample
Optional User defined
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
40/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 40 of 49
2.3.3 Potential Transformer Testing(PT Testing)A screen shot of the PT Testing screen is shown below:
The following table provides the details on each field shown on the screen above.
HEADER INFORMATION
Field Name Description Mandatory/Opt
ional
Values Comments
Name Select the
customer
name
Mandatory From the
Customer
information
Address System
display
automatically
Auto From the
Customer
Information
Not Editable
in Add/Modify
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
41/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 41 of 49
Customer Ref Date Enter the
customer
referencedate
Mandatory User defined Date format:
DD.MM.YYY
Y
Customer Ref No Enter the
customer
reference No
Mandatory User defined Duplication
controls on
Customer Ref
Date and
Customer Ref
No
SHS Date Enter the
SHS Date
Optional User defined Date format:
DD.MM.YYY
Y
SHS No Enter theSHS No
Optional User defined If SHS dateand SHS No
available then
system check
the duplication
on SHS Date
and SHS No
Gate Inward Date Enter the
Gate Inward
Date
Optional User Defined Date format:
DD.MM.YYY
Y
Gate Inward No Enter the
Gate Inward
No
Optional User defined If GI date and
GI No
available then
system check
the duplication
on GI Date
and GI No
Work Order Date Enter the
Work Order
Date
Optional User defined Date format:
DD.MM.YYY
Y
Work Order No Enter the
Work orderno
Optional User defined If WO date
and WO Noavailable then
system check
the duplication
on WO Date
and WO No.
Also if WO
details
available then
only user can
able to select
the test details.
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
42/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 42 of 49
Date of Sample
Receipt
Enter the
Date of
Samplereceipt
Optional User defined Date format:
DD.MM.YYY
Y
Date of Testing Enter the
date of
testing
Optional User defined Date format:
DD.MM.YYY
Y
Test Report Date Enter the
Test Report
Date
Optional User defined Date format:
DD.MM.YYY
Y
Test Report No Enter the
Test report
No
Optional User defined If TR date and
TR No
available then
system checkthe duplication
on TR Date
and TR No.
Also system
not allows the
report entry if
TR dates less
than parameter
value previous
report starts
date.
Tested By Select from
the list
Optional From User
Master
Checked By Select User
from List
Optional From User
Master
Value assign
from Report
approval by
authorized
user.
MFD.BY Enter the
name of
client
Optional User defined
No of Core Enter the no
of core
required
Mandatory User defined Numerical
value are only
allow
Ratio Select the
ratio from
the list
Mandatory From Parameter
value Master
under the type
Ratio
User can able
to select
multiple Ratio
Core Specification Select the
Core
Specification
from the list
Mandatory From Core
specification
under the Unit
Type PT
System
automatically
check the No
of Core isequal to select
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
43/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 43 of 49
the Core
Specification
NSV Select the NSV from
the list
Mandatory From Parameter Value Master
under the unit
type PT
I.L System
automatically
display the
value
Auto From Parameter
Value Master
System
automatically
generate Value
here But
Editable Field.
H.S.V System
automatically
display thevalue
Auto From Parameter
Value Master
System
automatically
generate Valuehere But
Editable Field.
S.T Current(kA) Enter the
value of
Standard
Transformer
Current
Optional User defined
Frequency (Hz) Enter the
frequency of
the current
transformer
testing
Mandatory User defined
V.K(min) Enter the v.k
for the
current
transformer
Optional User defined
IEX(min)@VK Enter the
IEX in
minute and
VK value
Optional User defined
RCT(max)@75C Enter theRCT Value
Optional User defined
INS.Class Enter the
Insulation
Class Value
for the
Current
Transformer
Testing
Optional User defined
Model Enter the
Model Name
Optional User defined
Sr. No Enter theSerial No of
Mandatory User defined
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
44/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 44 of 49
the Sample
Type Enter the
Type of Sample
Mandatory User defined
C/O Enter the
Carry off
value for the
sample
Optional User defined
Drawing No Enter the
Drawing No
of Sample
Optional User defined
ERDA
Identification No
Enter the
ERDA
IdentificationNo
Mandatory User defined
Remark Enter the
remarks if
any
Optional User defined
Test Details Select the
required test
to be perform
on the
Current
Transformer
Optional From Test
Detail Master
under type PT
Work order
date and Work
order no must
be entered
Result Select the
result on
completion
of all
selected tests
Optional 1. Confirm
2. Not
confirm
3. Result
as per
Remarks
4. Under
Testing
While adding
new test result
will be 4
defaults.
Section will be
shown to the
user if all tests
data are
available into
the system.
Remark For result as per remarks
selected,
Enter the
Test Result if
any
Optional User defined Section will beshown to the
user if all tests
data are
available into
the system.
Witness By Please enter
the general
notes if any
Optional User defined Section will be
shown to the
user if all tests
data are
available into
the system.
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
45/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 45 of 49
TEST DETAILS
TEST NAME: VERIFICATION TERMINAL MARKING AND POLARITY.
The user interface for the Terminal Marking & Polarity Test is shown below:
Field Name Description Mandatory/Optiona
l
Values Comments
Primary Winding
Terminals
Enter the
value of the
primary
winding
value for the
Sample
Mandatory User
defined
SecondaryWinding
Terminals
Systemgenerates
default
details
based on
the no of
core and
Ratio
selected
Mandatory User defined
User canchange if
any
Terminal marking
and polarity found
Select the
Terminal
marking andPolarity
Mandatory 1.O.K
2.Not O.k.
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
46/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 46 of 49
found value
TEST NAME: DETERMINATION OF ERROS ACCORDING TO THE
REQUIREMENT OF THE APPROPRIATE ACCURACY CLASS.
The user interface for the testing Accuracy Test is shown below. To capturing
a automatic data in a testing accuracy class system, Applitech Infotech has provided
the online solution by integrating with excel files. To enter the manual entry user has
to set the Capture from parameter value from Enable Capture Y Or N.
Enable Capture Y = automatic data in a testing accuracy class system.
Enable Capture N= User defined.
The following table provides the details on each field shown on the screen above.
Field Name Description Mandatory/Optional Values Comments
Ratio Select the
Ratio from
the list
Mandatory From
Header
Details
Core
Specification
Select the
Core
Specification
from the list
Mandatory From
Header
Details
Burden (%) Select the
Burden (%)
Mandatory From
ParameterValue under
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
47/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 47 of 49
type Burden
(%)
Current Rated(%)
Select theCurrent Rated
(%)
Mandatory FromParameter
Value under
type
Current
Rated (%)
Phase Angle
Error(Min)
Enter the
Phase Angle
Error
Mandatory User Define
Ratio Error
(%)
Enter the
Ratio Error
(%)
Mandatory User Define
Accuracy
Class
Enter the
Accuracy
Class
Mandatory User Define System Check
All Row are
unique on
Ratio, Core
Specification,
Applied
Burden and
Current Rated
%
TEST NAME: POWER FREQUENCY DRY WITHSTAND TEST ONSECONDRAY WINDING.
The user interface for the secondary winding Test is shown below:
The following table provides the details on each field shown on the screen above.
Field Name Description Mandatory/Option Values Comment
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
48/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 48 of 49
al
Power
FrequencyVoltage(KV)
Enter the Power
FrequencyVoltage(KV) and
select power
frequency
voltage %
Mandatory User
Defined
Default
value 3
Secondary
winding
terminals
System
automatic
generate
secondary
winding terminal
values based on
the No of Coreand Ratio
Selected in to the
Header details
Mandatory User defined
CT Result Enter the CT
result
Mandatory User
Defined
Default No
disruptive
and
withstood
TEST NAME: MEASUREMENT OF PARTIAL DISCHARGE.
The interface of Partial Discharge Measurement is shown below:
8/14/2019 Automated Reports Generation System for High Voltage Division Software Design
49/49
ERDADOC# HCCT-SDD-1120
REVISION: 0
AUTOMATED REPORTS GENERATIONSYSTEM FOR HIGH VOLTAGE DIVISION
ISSUE DT:11/20/09
SOFTWARE DESIGN DOCUMENT PAGE 49 of 49
Field Name Description Mandatory/Optional Values Comment
Pre-Stress
Voltage(Um)
Enter the Pre-
StressVoltage(Um)
Mandatory User
Define
System
automaticallydisplay
default value
Duration(Sec) Enter the
Duration
with sign
Mandatory User
Define
System
automatically
display
default value
Reduce
Voltage(Um)
Enter the
Reduce
Voltage
Mandatory User
Define
System
automatically
display
default value
DurationMaintained(Min)
Enter theDuration
Maintained
with sign
Mandatory User Define
Systemautomatically
display
default value
Magnitude
Voltage(pC)
Enter the
Magnitude
Voltage
Mandatory User
Define
System
automatically
display
default value
Limit Of Pd
Quantity(pC)
Enter the
Limit if PD
Quantity
Mandatory User
Define
System
automatically
displaydefault value