Automated 2D IR Spectroscopy using a high

repetition rate laser system and mid IR pulse shaper

Sudipta MukherjeeZanni Group

Department of ChemistryUniversity of Wisconsin at Madison

Page 2: Automated 2D IR Spectroscopy using a high repetition rate laser system and mid IR pulse shaper Sudipta Mukherjee Zanni Group Department of Chemistry University

2D IR Spectroscopy-The vibrational analogue of 2D NMR

• Molecular Structures-Vibrational frequency ,coupling, anharmonicity, transition dipole angles

• Ultrafast Dynamics-fast time resolution(fs/ps)• Environment-Lineshape analysis

2

Merits of 2D IR Spectroscopy

Scientific Problems

•Characterization of Transmembrane Proteins eg CD3ξ(receptor in T cells),Ovispirin(antibiotic polypeptide),M2(ion channel)etc•Studying folding kinetics eg HIAPP(HUMAN ISLET AMYLOID POLYPEPTIDE)

j

ij

ijj

i

jiprobe

pu

mp

| 0 0 >

| i 0 >| 0 j >

| 2i 0>

| 0 2j>| i j >

0

Ei

Ej

2Ei iEi Ej ij

2Ej j

local modes normal modes(a) (b)

Page 3: Automated 2D IR Spectroscopy using a high repetition rate laser system and mid IR pulse shaper Sudipta Mukherjee Zanni Group Department of Chemistry University

3

Examples of FTIR and 2D IR spectra of HIAPP

HIAPP-Human Islet Amyloid Polypeptide-Type 2 diabetes

Page 4: Automated 2D IR Spectroscopy using a high repetition rate laser system and mid IR pulse shaper Sudipta Mukherjee Zanni Group Department of Chemistry University

Traditional ways of doing 2D IR spectroscopy

Hole Burning Method•Easier • time resolution –less

Pulsed Photon Echo Method

•Difficult •Better time resolution

Page 5: Automated 2D IR Spectroscopy using a high repetition rate laser system and mid IR pulse shaper Sudipta Mukherjee Zanni Group Department of Chemistry University

Nd:YVO4

CW laserTi:Sapphire

Oscillator

StretcherRegenerative Amplifier

CompressorNd

:YL

Fn

s la

ser -BBO based

OPA

DifferenceFrequency

Mixingw/ AgGaS2

800 nm, 88 MHz. 2 nJ/pulse

idlerGe AOM

PulseShaper

Tunable mid-IR3-10 m, 2-5 J/pulse

800 nm, 1kHz, 1mJ/pulse

signal

beam dump

optical chopper

k1

kpump-probe= k1+k1+k2

sample

k1+k1 k2

monochromatorMCT array

--+

--+

Our Experiment set-up: automatic 2D IR spectrometer

Page 6: Automated 2D IR Spectroscopy using a high repetition rate laser system and mid IR pulse shaper Sudipta Mukherjee Zanni Group Department of Chemistry University

6

How to generate the double pulses-pulse shaper

•Ge-AOM is used as a modulated grating•Phase and amplitude tailored by a 75 Mhz acoustic wave of bandwidth 50 Mhz

Page 7: Automated 2D IR Spectroscopy using a high repetition rate laser system and mid IR pulse shaper Sudipta Mukherjee Zanni Group Department of Chemistry University

7

Advantages of the pulse shaping method•Easier alignment. •Little maintenance.•Fast data collection.• Absorptive spectra-no phasing needed!• Complicated pulse shapes, higher dimension.

Page 8: Automated 2D IR Spectroscopy using a high repetition rate laser system and mid IR pulse shaper Sudipta Mukherjee Zanni Group Department of Chemistry University

8

However….

Page 9: Automated 2D IR Spectroscopy using a high repetition rate laser system and mid IR pulse shaper Sudipta Mukherjee Zanni Group Department of Chemistry University

9

• More averaging over larger number of laser shots.S/N almost 6 times•Even faster data collection-0.3 s•Even lower sample concentration to mimic physiological conditions.

Moving towards even faster data collection

30 Khz laser!!A complete laser system including oscillator, cryo cooled amplifier and pump lasers-KM LABS

•Rep Rate:50 KHz•Pulse Duration:40 fs(expected)•Pulse Energy:300-500 uJ

Cryo-cooling and Downchirped Pulse Amplification gives high rep rate withnot much loss of power.

Page 10: Automated 2D IR Spectroscopy using a high repetition rate laser system and mid IR pulse shaper Sudipta Mukherjee Zanni Group Department of Chemistry University

Summary:

10

•Hence programmable pulse generation in MID IR achieved.

•Easier implementation of 2D IR spectroscopy.

•We expect to get even better structural resolution with our new laser system.

•Understand the role of intermediates in HIAPP folding.

Page 11: Automated 2D IR Spectroscopy using a high repetition rate laser system and mid IR pulse shaper Sudipta Mukherjee Zanni Group Department of Chemistry University

Acknowledgement

• Dr Martin Zanni• Sang-Hee Shim • Dave Strasfeld • Ann Woys • Wei Xiong • Emily Blanco• Yun Ling• Dr Chris Middleton• Dr Prabudhdha Mukherjee

Thanks for your attention!