Australia Drilling Flare Tanks

Embed Size (px)

Citation preview

  • 8/11/2019 Australia Drilling Flare Tanks

    1/2

    Information Technology Solutions

    Flare Tanks are used to dispose of gas dischargedfrom the wellhead during well control events.

    Two modes of operaon are ulised:

    Flare Tank Specicaons:

    Operang Pressure Capacity (up to):

    5,000 psi

    Volume (up to & including): 12m3

    Gas Flow Rates (up to): 17.5 mmscf/d.

    (Million Standard Cubic Feet per Day)

    Praccal Engineerings Range of Flare Tanks for Gas Drilling

    Client Customisaon:Flares can be customised to suit specic rig requirements. We have designed

    ares to be used across the CSG, Shale/ Gas Sands, Deep Gas and

    HPHT (High Pressure, High Temperature) drilling industries.

    Gas DisposalThe primary mode of operaon is disposal of gas separated at the rig

    degasser. Gas is piped via a large diameter (2-8) low pressure

    aring line. The gas is vented to the are stack and ignited by the

    are pilots.

    Mud-Gas SeparaonAlternately drilling mud and gas mixtures are discharged directly from

    the choke manifold via a high pressure (5000psi) panic line. The integral

    separaon diverts the gas to the are stack for aring whilst the mud is

    separated and retained in the mud storage tank for return to the rig

    mud system.

    Address: 1 Colebard Street East, Acacia Ridge, QLD 4110.www.praceng.com.au

    Creave thinking. Praccal Soluons

  • 8/11/2019 Australia Drilling Flare Tanks

    2/2

    ICAMS Ignion Controland Management System

    Praccal Engineering has developed

    the ICAMS module to give the utmost

    are control and safety.

    The unit maintains pilot operaon and

    alerts the operator if the pilot gas bole

    requires changing or a fault has been

    detected.

    Creave thinking. Praccal Soluons

    Address: 1 Colebard Street East, Acacia Ridge, QLD 4110.

    Features & Benets of our Flare Tank Range

    Compliance

    All Applicable Australian Standards

    (AS) Inc. Structural & Liing

    American Petroleum Instute (API)

    Regulaons on Flare Systems Australian Gas Authority (AGA) Class 1

    safe start check and a connual

    self-check.

    Safety

    Heat ux calculaons are undertaken for each aring system to ensure the

    required operator exclusion zone is setup.

    The are system ensures that the control panel is outside the zone 2

    hazardous area.

    User Friendly Operaon

    The are tank is supplied with:

    A comprehensive installaon,

    operaon and maintenance

    manual Short succinct informaon

    required to setup and

    Site operaon training and com-

    missioning available as required

    Environment

    Praccals range of pit-less Flaring

    Tanks oer minimum possible

    impact on the environment.

    The are system removes any need

    or expenditure on earthworks,

    excavang, lining or remediang a

    are pit.

    Fast Rig-UpRig-up is quick and simple. One operator

    can deploy the are tank and erect the

    are stack within 20 minutes.

    www.praceng.com.au