Flare Tanks are used to dispose of gas dischargedfrom the wellhead during well control events.
Two modes of operaon are ulised:
Flare Tank Specicaons:
Operang Pressure Capacity (up to):
5,000 psi
Volume (up to & including): 12m3
Gas Flow Rates (up to): 17.5 mmscf/d.
(Million Standard Cubic Feet per Day)
Praccal Engineerings Range of Flare Tanks for Gas Drilling
Client Customisaon:Flares can be customised to suit specic rig requirements. We have designed
ares to be used across the CSG, Shale/ Gas Sands, Deep Gas and
HPHT (High Pressure, High Temperature) drilling industries.
Gas DisposalThe primary mode of operaon is disposal of gas separated at the rig
degasser. Gas is piped via a large diameter (2-8) low pressure
aring line. The gas is vented to the are stack and ignited by the
are pilots.
Mud-Gas SeparaonAlternately drilling mud and gas mixtures are discharged directly from
the choke manifold via a high pressure (5000psi) panic line. The integral
separaon diverts the gas to the are stack for aring whilst the mud is
separated and retained in the mud storage tank for return to the rig
mud system.
Address: 1 Colebard Street East, Acacia Ridge, QLD 4110.www.praceng.com.au
Creave thinking. Praccal Soluons
8/11/2019 Australia Drilling Flare Tanks
2/2
ICAMS Ignion Controland Management System
Praccal Engineering has developed
the ICAMS module to give the utmost
are control and safety.
The unit maintains pilot operaon and
alerts the operator if the pilot gas bole
requires changing or a fault has been
detected.
Creave thinking. Praccal Soluons
Address: 1 Colebard Street East, Acacia Ridge, QLD 4110.
Features & Benets of our Flare Tank Range
Compliance
All Applicable Australian Standards
(AS) Inc. Structural & Liing
American Petroleum Instute (API)
Regulaons on Flare Systems Australian Gas Authority (AGA) Class 1
safe start check and a connual
self-check.
Safety
Heat ux calculaons are undertaken for each aring system to ensure the
required operator exclusion zone is setup.
The are system ensures that the control panel is outside the zone 2
hazardous area.
User Friendly Operaon
The are tank is supplied with:
A comprehensive installaon,
operaon and maintenance
manual Short succinct informaon
required to setup and
Site operaon training and com-
missioning available as required
Environment
Praccals range of pit-less Flaring
Tanks oer minimum possible
impact on the environment.
The are system removes any need
or expenditure on earthworks,
excavang, lining or remediang a
are pit.
Fast Rig-UpRig-up is quick and simple. One operator
can deploy the are tank and erect the
are stack within 20 minutes.
www.praceng.com.au