    HK AURORA/PSY LIGHTING

    SPECIFICATION

    Company Name

    Product Name 75W

    Part No 075-H

    For customer fill

    Confirmed department

    Confirmed result

    Signature

    Approve)

    Auditing)

    Make)

  • 8/11/2019 Aurora Appendix Product Reference

    3/23

    Features :

    1. Astheworld'sfirstnewproducts,LEDbigbulbcoulddisplacethecompactTraditionalCFLlight.

    2. Uniquestructure,wideangled(360),WiderangeofIrradiatedArea.

    3. Smartheatdispersionstructure(patentdesign).

    4. Offerthewellmixedfacular,withouttheshadowresult,longoperatinglifeandlowlumensdepreciation.

    5. Variouslampholderareavailable,awiderangeofapplications.(E39/E40,E26/E27)

    6. WidevoltageAC85265V.

    7. UsingFansforbettercooling

    8. UsingFanprotectioncircuit,whenfanscouldnotwork,thepowerofwholelampwillbereduced50%to

    ensurethesafetyofthelamps.

    9. MeettheCEstandard

    Product Appearance :

    Dimensions

  • 8/11/2019 Aurora Appendix Product Reference

    4/23

    MAIN SPECIFICATIONS t=20)

    PSY/AURORA-CORN LIGHT-075H

    5730

    7500LM

    COLD WHITE, NATUAL ,WARM WHITE

    >72

    CIRCLE

    35000

    AC 85 265

    50/60 Hz

    346

    752W

    0.95

  • 8/11/2019 Aurora Appendix Product Reference

    5/23

    Research Report:

  • 8/11/2019 Aurora Appendix Product Reference

    6/23

    Fixing Ways:

    UP OR DOWNSIDE

    CORRECT WRONG

    Packing

    15

    L W H Kg

    Inner Box

    120mm 120mm 340mm 1.0

    Outer Box

    615mm 255mm 360mm 11

    2*510PCS

  • 8/11/2019 Aurora Appendix Product Reference

    7/23

    Applications :

    BOTH INDOOR AND OUTDOOR WITH FULL PROTECTION

  • 8/11/2019 Aurora Appendix Product Reference

    8/23

    Issued November 2009 12498

    DATA SHEET

    C60 & C120

    MCB

    Based on Schneider Electric Catalogue

  • 8/11/2019 Aurora Appendix Product Reference

    9/23

    Protection

    Circuit Breaker Limitation Capability

    The limitation capability of a circuit breaker is that characteristic wherebyonly a current less than the prospective fault current is allowed to flow undershort-circuit conditions.

    This is illustrated by limitation curves which give:

    " The limited peak current in relation to the

    RMS value of the prospective short-circuitcurrent (the short-circuit current being thatcurrent which would flow continuously in theabsence of protection equipment).

    " The limited current stress in relation to theRMS value of the prospective short-circuitcurrent.

    " Current limiting capability. The advanceddesign of the Multi-9 range provides currentlimitation with far better protection than con-ventional circuit breakers. For example, on a

    6A rating with a prospective short circuit of5000A, the current will be limited at 350A or7%.

    Installation of current limiting circuit breakersoffers several advantages:

    # Better network protectionCurrent limiting circuit breakers considerablyreduce the undesirable effects of short-circuitcurrents in an installation.

    # Reduced thermal effectsCable heating is reduced, hence longer cablelife.

    # Reduced mechanical effectsElectrodynamic forces reduced, thus electri-cal contacts are less likely to be deformed orbroken.

    # Reduced electromagnetic effectsMeasuring equipment situated near an elec-

    trical circuit less affected.

    Trip Unit Variations Circuit Breaker Marking

    Curve Btripping:3 to 5 times the ratedcurrent (In);protection of generators,

    persons, very longcables.

    Curve Ctripping:5 to 10 In;protection of circuits,

    general applications.

    Curve Dtripping:

    10 to 14 In;protection of high surgecircuits, welders, trans-formers, motors.

    Curve MA(magnetic only)tripping: 12 In;protection of motor

    starters (+ thermal pro-

    tection when combinedwith contactor).

    Circuit Protection

    A choice of several curvesWhatever circuit has to be pro-tected, a C60 or C120 circuit

    breaker provides the perfectsolution with a suitable curve.

    1. Circuit Breaker Model Number

    2. Tripping Curve

    3. Circuit Breaker Current Rating

    4. Operating Voltage

    5. Rated Breaking Capacity

    6. Circuit Breaker Part Number

    7. Electrical Diagram - No. of Poles

    8. I2t classification

    Merlin Gerin Multi 9 SystemMiniature circuit breakersTripping curvesMarkings & limitation capability

    1

    2

    3

    4

    5

    8

    C60H

    C63415V~10000

    3

    2 ....

    1

    2

    3

    4

    5

    6

    6 7

    multi 9

    1249

  • 8/11/2019 Aurora Appendix Product Reference

    10/23

    protection

    circuit-breakers up to 63 A

    C60a circuit-breakers4.5 kA, C curveAS/NZS 4898 Approval No: N13634

    functions

    description technical dataC60a circuit-breakers

    c power circuitv voltage rating: 240 V ACv number of cycles (O-C): 10 000v foolproof terminal design- moving barrier prevents incorrect cableinsertion- cable strand centering guides ensure

    correct cable positions and strand groupingv isolation with positive contact indicationv bistable din clip, simplifies disassembly

    c environmentv tropicalisation: treatment 2(relative humidity: 95 % at 55 C)v connection: tunnel terminals for thefollowing cables:- up to 25A : 25mm2stranded- 32 to 63A : 35mm2stranded

    The circuit-breakers combine the followingfunctions:- protection of circuits against short-circuitcurrents,

    - protection of circuits against overloadcurrents,- control,

    - protection of persons against indirectcontact.

    - C60a circuit-breakers are used in the

    domestic sectors where single phase faultlevels are less than or equal to 4.5kA.

    C curve

    utilisationcables feeding conventional loads.

    technical data

    cpower circuitv tripping curves: the magnetic trip unitoperates between 5 and 10 In

    v breaking capacity- according to AS/NZS 4898 Icu ultimatebreaking capacity (0-C0 cycle):

    type rating catalogue width quantity

    (A) number in mod. per box

    of 9 mm

    C curve C60a

    1P 6 11354 2 1210 11355 2 1216 11356 2 12

    20 11357 2 1225 11339 2 12

    32 11358 2 12

    40 11359 2 1250 11360 2 12

    63 11361 2 12

    1

    2

    catalogue numbers

    11357

    - isolation,

    rating voltage breaking

    (A) (V) capacity

    Icu (A)

    1...63 240 4500

    1249

  • 8/11/2019 Aurora Appendix Product Reference

    11/23

    protection

    circuit-breakers up to 63 A

    C60N circuit-breakers6kA, C curveAS/NZS 4898 Approval No: N13634

    functions

    description technical data common toC60N circuit breakers

    c power circuitv voltage rating: 240/415 V AC- for 2P single phase 240/480VvI2t classification: 3v number of cycles (O-C): 20 000v foolproof terminal design- moving barrier prevents incorrect cableinsertion- cable strand centering guides ensure

    correct cable positions and strand groupingv isolation with positive contact indicationv bistable din clip, simplifies disassembly

    c environmentv tropicalisation: treatment 2(relative humidity: 95 % at 55 C)v connection: tunnel terminals for thefollowing cables:- up to 25A : 16mm2flexible with cable end

    : 25mm2stranded- 32 to 63A : 25mm2flexible with cable end

    : 35mm2stranded

    C curve

    utilisationcables feeding conventional loads.

    technical data

    cpower circuitv tripping curves: the magnetic trip unitsoperate between 5 and 10 Inv breaking capacity according toAS/NZS 4898, Icu ultimate breaking capacity

    (O-CO cycle):

    rating type voltage breaking

    capacity(A) (V) Icu (A)

    163 1P 240/415 6 0002P 415...480 6 0003P 415 6 000

    The circuit-breakers combine the followingfunctions:- protection of circuits against short-circuitcurrents,

    - protection of circuits against overloadcurrents,- control,

    - isolation,- protection of persons against indirectcontact.

    catalogue numbers type rating catalogue(A) number

    C curve C60N

    1P 1 25797

    2 25798

    4 25800

    6 25801

    10 25802

    16 25803

    20 25804

    25 25805

    32 25806

    40 25807

    50 25808

    63 25809

    2P 1 25811

    2 25812

    4 25814

    6 2581510 25816

    16 25817

    20 25818

    25 25819

    32 25820

    40 25821

    50 25822

    63 25823

    3P 1 258252 25826

    4 25828

    6 25829

    10 25830

    16 25831

    20 2583225 25833

    32 25834

    40 25835

    1

    2

    3

    4

    5

    6

    25804

    1

    2

    1

    2

    3

    4

    25818

    Width in mod

    of 9mm - 2

    Width in modof 9mm - 4

    Width in modof 9mm - 6

    1249

  • 8/11/2019 Aurora Appendix Product Reference

    12/23

    protection

    circuit breakers up to 125A

    C120N circuit-breakers10kA, B, C curves - AS/NZS 489810kA, D curve AS 3947-2

    function The circuit-breakers combine the followingfunctions:- protection of circuits against short circuitcurrents,

    - protection of circuits against overloadcurrents,- control,

    Technical data common to C120N circuitbreakers

    c power circuitv current rating: 63 to 125 Av voltage rating 415 V ACvinsulation voltage Ui: 500 Vvimpulse withstand voltage Uimp: 6 kVv breaking capacity:- according to AS/NZS 4898 Icv ultimate

    breaking capacity (O-CO cycle)type voltage breaking cap.

    (V) Icu (A)1, 2, 3, 4P 240/415 10000

    vaccording to AS3947-2 Icu ultimatebreaking capacity (O-CO cycle)

    type voltage breaking cap.(V) Icu (kA)

    1P 240 10

    415 32, 3, 4P 400415 10

    v mechanical durability:- 20000 cycles (O-C)v electrical durability:

    - 63 A: 10000 cycles (O-C)- 80125 A: 5000 cycles (O-C)v I2t classification: 3v isolation with positive contact indication:opening is indicated by a green strip on thedevice operating handle. This indicatorshows opening of all the polesv foolproof terminal design- moving barrier prevents incorrect cableinsertion- cable strand centering guides ensurecorrect cable positions and strand groupingv bistable din clip: simplifies disassemblyv 63 to 125A: - up to 35mm2 flexible with

    cable end- up to 50mm2 stranded

    description

    - isolation,- protection of persons against indirectcontact.

    B curve

    utilisationwhen there are small inrush currents(generators, long cables).

    technical data

    c power circuitvtripping curve:

    the magnetic trip units operate between3 and 5 In.

    C curve

    utilisationcables feeding conventional loads.

    technical data

    c power circuitvtripping curve:the magnetic trip units operate between 5and 10 In.

    D curve - For industrial use only

    utilisationloads with a high inrush current(motors, transformers).

    technical data

    c power circuitv tripping curve:the magnetic trip units operate between10 and 14 In.

    Approval No:Q00542

    Approval No:Q00542

    1249

  • 8/11/2019 Aurora Appendix Product Reference

    13/23

    protection

    circuit-breakers up to 125 A

    C120N circuit-breakers10kA, B, C curves - AS/NZS 489810kA, D curve AS 3947-2

    18340

    18344

    1

    2

    31

    42

    catalogue numbers

    18349

    18355

    531

    642

    7531

    8642

    type rating B C D

    (A) Curve Curve Curve

    B curve C120N

    1P 63 18340 18356 18378

    80 18341 18357 18379

    100 18342 18358 18380

    125 18343 18359 18381

    2P 63 18344 18360 18382

    80 18345 18361 18383

    100 18346 18362 18384

    125 18347 18363 18385

    3P 63 18348 18364 18386

    80 18349 18365 18387

    100 18350 18367 18388

    125 18351 18369 18389

    4P 63 18352 18371 18390

    80 18353 18372 18391

    100 18354 18374 18392

    1 25 18355 18377 18393

    Width in mod

    of 9mm - 3

    Width in mod

    of 9mm - 6

    Width in mod

    of 9mm - 9

    Width in modof 9mm - 12

    1249

  • 8/11/2019 Aurora Appendix Product Reference

    14/23

    Dimensions

    C60a/N/H circuit breakers Vigi C60

    C120N/H circuit breakers

    C60/C120 auxiliaries

    Vigi C120

    27

    54

    81

    81 45

    44

    73

    16

    5.5 5.5

    6.5

    7

    34

    7max3

    max

    21.2

    84.3

    108

    2P

    1P

    3P

    4P

    OFF OFF OFF OFF

    108

    2P 2P

    3P 3-4P

    4P

    81 90

    87

    18

    45

    44

    6354

    95

    73

    16

    5.5

    OFF OFF OFF OFF

    9 9 18 36

    81 45

    1644

    5.5 73

    81 45

    1644

    5.5 73

    OF+SD/

    OF

    OF+SD/OFOF, SD

    OF, S

    MX

    MN

    MN s

    36

    81OFF

    12

    81OFF OFF OFF OFF

    12

    20

    81OFF OFF

    C60 accessories

    C120 accessories

    1249

  • 8/11/2019 Aurora Appendix Product Reference

    15/23

    Product data sheetCharacteristics

    A9R11463iID 4P 63A 30mA AC-type

    Main

    Range of product IID

    Device short name IID

    Poles description 4P

    Neutral position Left

    Network type AC

    Complementary

    Device location in system Outgoer

    [In] rated current 63 A

    Network frequency 50/60 Hz

    [Ue] rated operational voltage 400 V EN 61008-1 AC 50/60 Hz

    400/415 V IEC 61008-1 AC 50/60 Hz

    Residual current tripping technology Voltage independent

    Earth-leakage sensitivity 30 mA

    Earth-leakage protection time delay Instantaneous

    Earth-leakage protection class Class AC

    Rated breaking and making capacity 1500 A Idm1500 A Im

    Rated conditional short-circuit current 10 kA

    Contact position indicator Yes

    Control type Toggle

    Local signalling Trip indicator

    Mounting mode Removable comb busbar installed

    Mounting support DIN rail

    9 mm pitches 8

    Width 72 mm

    Connections - terminals Tunnel terminal with flap

    Environment

    Standards EN 61008-1

    IEC 61008-1

    RoHS EUR status Compliant

    RoHS EUR conformity date 1001

  • 8/11/2019 Aurora Appendix Product Reference

    16/23

    3RH Contactor Relays

    3RH2 contactor relays, 4- and 8-pole

    3/58 SIRIUS Innovations Supplement 2011

    3

    Overview

    Contactor relays and coupling relaysSize S00 with accessories

    Contactor relay

    Coupling relay for auxiliary circuits

    Solid-state timing relay block

    1-pole auxiliary switch block, cable entry from above

    2-pole auxiliary switch block, cable entry from above

    1-pole auxiliary switch block, cable entry from below

    2-pole auxiliary switch block, cable entry from below

    4-pole auxiliary switch block(terminal designations according to EN 50011 or EN 50005)

    2-pole auxiliary switch block, solid-state compatible versionTerminal designations according to EN 50005

    Solder pin adapter for contactor relays with 4-pole auxiliary switch block

    Solder pin adapter for contactor relays and coupling relays

    Additional load module for increasing the permissible residual current

    Surge suppressor with LED

    Surge suppressor without LED

    3

    4

    5

    6

    7

    8

    9

    10

    11

    14

    12

    13

    1

    2

    10

    11

    11

    NSB0_

    02058

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    14

    Siemens AG 2011

  • 8/11/2019 Aurora Appendix Product Reference

    17/23

    3RH Contactor Relays

    3RH2 contactor relays, 4- and 8-pole

    3/59SIRIUS Innovations Supplement 2011

    AC and DC operation

    IEC 60947, EN 60947.

    The 3RH2 contactor relays have screw, ring lug terminal orspring-type terminals. Four contacts are available in the basicunit.

    The 3RH2 contactor relays are suitable for use in any climate.They are finger-safe according to EN 50274. The devices withring lug terminal connection comply with degree of protectionIP20 when fitted with the related terminal cover.

    Contact reliability

    High contact stability at low voltages and currents, suitable forsolid-state circuits with currents 1 mA at a voltage of 17 V.

    Surge suppression

    RC elements, varistors, diodes or diode assemblies (combina-tion of a diode and a Zener diode) can be plugged onto all con-tactor relays from the front for damping opening surges in thecoil. The plug-in direction is determined by a coding device.

    Note:The OFF-delay of the NO contact and the ON-delay of theNC contact are increased if the contactor coils are attenuatedagainst voltage peaks (noise suppression diode 6 to 10 times;diode assemblies 2 to 6 times, varistor +2 to 5 ms).

    Auxiliary switch blocks

    The 3RH2 contactor relays can be expanded by up to fourcontacts by the addition of snap-on auxiliary switch blocks.

    The auxiliary switch block can easily be snapped onto the frontof the contactors. The auxiliary switch block has a centrally po-sitioned release lever for disassembly.

    The contactor relays with 4 contacts according to EN 50011,with the identification number 40E, can be extended with 80E to44E auxiliary switch blocks to obtain contactor relays with8 contacts according to EN 50011. The identification numbers80E to 44E on the auxiliary switch blocks apply to the completecontactors. These auxiliary switch blocks (3RH29 111GA..)

    cannot be combined with contactor relays with identificationnumbers 31E and 22E; they are coded.

    All contactor relays with 4 contacts according to EN 50011, iden-tification numbers 40E to 22E, can be extended with auxiliaryswitch blocks 40 to 02 to obtain contactor relays with 6 or 8 con-tacts in accordance with EN 50005. The identification numberson the auxiliary switch blocks apply only to the attached auxiliaryswitch blocks.

    In addition, fully mounted 3RH22 8-pole contactor relays areavailable; the mounted 4-pole auxiliary switch block in the 2ndtier is not removable. The terminal designations are according toEN 50011.

    These versions are built according to special Swiss regulationsSUVA and are distinguished externally by a red labeling plate.

    Of the auxiliary contacts (integrated plus mountable) possibleon the device, no more than four NC contacts are permitted.

    Order No. scheme

    Note:

    The Order No. scheme is presented here merely for informationpurposes and for better understanding of the logic behind theorder numbers.

    For your orders, please use the order numbers quote in thecatalog in the Selection and ordering data.

    Hilfsschtze

    DIN EN50 005,

    8 oder 6 Kontakte

    NSB0_

    021

    05

    Ident. No. 31E, 22EIdent. No. 40E

    Ident. No. 80E,

    71E, 62E, 53E, 44E

    Aux. switch blocks,

    EN 50 011,

    4 contacts

    Ident. No. 40, 31,

    22, 20, 11, 02

    Aux. switch blocks,

    EN 50 005,

    4 or 2 contacts

    Ident. No. 80E,

    71E, 62E, 53E, 44E

    Contactor relay,

    EN 50 011

    8 contacts

    Contactor relay,

    EN 50 005,

    8 or 6 contacts

    Contactor relay, EN 50 011,4 contacts

    Digit of the Order No. 1st -3rd

    4th 5th 6th 7th 8th 9th 10th 11th 12th

    13th 14th 15th 16th

    @@@ @ @ @ @ @ @ @ @ @ @ @ @ @

    SIRIUS contactor relays 3 R H

    2nd generation 2

    Device type (e. g. 1 = 4-pole contactor relay, 3 = 8-pole contactor relay) @

    Number of NO contacts (e. g. 2 = 2 NO) @

    Number of NC contacts (e. g. 2 = 2 NC) @

    Connection type (1 = screw, 2 = spring, 4 = ring lug) @

    Operating range / solenoid coil circuit (e. g. A = AC standard / without) @

    Rated control supply voltage (e. g. K6 = 110/120 V, 50/60 Hz ) @ @

    No significance @

    Special version @ @ @ @

    Example 3 R H 2 1 2 2 1 A K 6 0

    Siemens AG 2011

  • 8/11/2019 Aurora Appendix Product Reference

    18/23

    3RH Contactor Relays

    3RH2 contactor relays, 4- and 8-pole

    3/60 SIRIUS Innovations Supplement 2011 Illustrations are approximate

    3

    Selection and ordering data

    AC operation

    For other voltages see page 3/62.

    For accessories see pages 3/93 to 3/97.

    1) The 3RH21 contactor relays are also available with ring lug terminal con-nection. Please insert the number "4" into the 8thposition of the part num-ber for versions with ring lug terminal connection.

    2) Coil operating rangeat 50 Hz: 0.8 to 1.1 x Usat 60 Hz: 0.85 to 1.1 x Us.

    3) For AC-15/AC-14 the following applies: Ie= 6 A for mounted auxiliarycontacts.

    Size S00

    3RH21 . .-1. . . . 3RH21 . .-2. . . . 3RH22 . .-1. . . . 3RH22 . . -2 . . . .

    Rated opera-tional currentat240 V

    Contacts Rated control supplyvoltage Usat 50/60 Hz2)

    Screw terminals1) Weightapprox.

    Spring-typeterminals

    Weightapprox.Ident.

    No.Version

    Order No. Order No.

    A NO NC V AC kg kg

    For screw and snap-on mounting onto TH 35 standard mounting railTerminal designations according to EN 50011

    4 NO, identification number 40E 3 NO + 1 E, identification number 31E 2 NO + 2 NE, identification number 22E

    10 40E 4 -- 24 3RH21 40-1AB00 0.220 3RH21 40-2AB00 0.240110/120 3RH21 40-1AK60 0.220 3RH21 40-2AK60 0.240220/240 3RH21 40-1AP60 0.220 3RH21 40-2AP60 0.240

    31E 3 1 24 3RH21 31-1AB00 0.220 3RH21 31-2AB00 0.240110/120 3RH21 31-1AK60 0.220 3RH21 31-2AK60 0.240220/240 3RH21 31-1AP60 0.220 3RH21 31-2AP60 0.240

    22E 2 2 24 3RH21 22-1AB00 0.220 3RH21 22-2AB00 0.240110/120 3RH21 22-1AK60 0.220 3RH21 22-2AK60 0.240220/240 3RH21 22-1AP60 0.220 3RH21 22-2AP60 0.240

    With permanently mounted auxiliary switch block

    4 NO + 4 NC, identification number 44E 6 NO + 2 NC, identification number 62E

    103) 44E 4 4 110/120 3RH22 44-1AK60 0.270 3RH22 44-2AK60 0.300

    62E 6 2 110/120 3RH22 62-1AK60 0.270 3RH22 62-2AK60 0.300

    Siemens AG 2011

  • 8/11/2019 Aurora Appendix Product Reference

    19/23

    YW SeriesControl Units22

    Note: Specify a lens color code in place ofin the Type No.

    Clear lenses are used for PW (pure white) illumination of pilot lights.

    Pilot Lights

    Style Illumination Type Operating Voltage Type No. Lens Color Code

    FlushFull Voltage Without Lamp 250V AC/DC max. YW1P-1EQ0

    A (amber), C (clear),G (green), R (red), S (blue),

    W (white), Y (yellow)

    LED

    6V AC/DC YW1P-1EQ2

    A (amber), G (green),PW (pure white), R (red),S (blue), W (white), Y (yellow)

    Built-in LED lamp: LSED-

    12V AC/DC YW1P-1EQ3

    24V AC/DC YW1P-1EQ4

    110V AC/DC YW1P-1EQH

    230/240V AC/DC YW1P-1EQM3

    Incandescent

    6V AC/DC YW1P-1EQ5 A (amber), C (clear),G (green), R (red), S (blue),W (white), Y (yellow)

    Built-in incandescent lamp: LS-T

    12V AC/DC YW1P-1EQ6

    24V AC/DC YW1P-1EQ7

    Flush

    Transformer Type

    LED

    100/110V AC YW1P-1EH2

    A (amber), G (green),PW (pure white), R (red),S (blue), W (white), Y (yellow)

    Built-in LED lamp: LSED-6

    200/220V AC YW1P-1EM2

    115/120V AC YW1P-1EH22

    230/240V AC YW1P-1EM42

    Incandescent

    100/110V AC YW1P-1EH5

    A (amber), C (clear),G (green), R (red), S (blue),W (white), Y (yellow)

    Built-in incandescent lamp: LS-T6

    200/220V AC YW1P-1EM5

    115/120V AC YW1P-1EH25

    230/240V AC YW1P-1EM45

    Flush Marking TypeFull Voltage

    Without Lamp 250V AC/DC max. YW1P-1BEQ0A (amber), G (green), R (red),S (blue), W (white), Y (yellow)

    LED

    6V AC/DC YW1P-1BEQ2

    A (amber), G (green),PW (pure white), R (red),S (blue), W (white), Y (yellow)

    Built-in LED lamp:LSED-

    12V AC/DC YW1P-1BEQ3

    24V AC/DC YW1P-1BEQ4

    110V AC/DC YW1P-1BEQH

    230/240V AC/DC YW1P-1BEQM3

    Incandescent

    6V AC/DC YW1P-1BEQ5A (amber), G (green), R (red),S (blue), W (white), Y (yellow)

    Built-in incandescent lamp: LS-T

    12V AC/DC YW1P-1BEQ6

    24V AC/DC YW1P-1BEQ7

    Flush Marking TypeTransformer Type

    LED

    100/110V AC YW1P-1BEH2A (amber), G (green),PW (pure white), R (red),S (blue), W (white), Y (yellow)

    Built-in LED lamp:LSED-6

    200/220V AC YW1P-1BEM2

    115/120V AC YW1P-1BEH22

    230/240V AC YW1P-1BEM42

    Incandescent

    100/110V AC YW1P-1BEH5

    A (amber), G (green), R (red),S (blue), W (white), Y (yellow)

    Built-in incandescent lamp: LS-T6

    200/220V AC YW1P-1BEM5

    115/120V AC YW1P-1BEH25

    230/240V AC YW1P-1BEM45

  • 8/11/2019 Aurora Appendix Product Reference

    20/23

    YW SeriesControl Units 22

    Note: Specify a lens color code in place of in the Type No.

    Clear lenses are used for PW (pure white) illumination of pilot lights.

    Style Illumination Type Operating Voltage Type No. Lens Color Code

    ExtendedFull Voltage Without Lamp 250V AC/DC max. YW1P-2TEQ0

    A (amber), C (clear),G (green), R (red), S (blue),W (white), Y (yellow)

    LED

    6V AC/DC YW1P-2TEQ2

    A (amber), G (green),PW (pure white), R (red),S (blue), W (white), Y (yellow)

    Built-in LED lamp: LSED-

    12V AC/DC YW1P-2TEQ3

    24V AC/DC YW1P-2TEQ4

    110V AC/DC YW1P-2TEQH

    230/240V AC/DC YW1P-2TEQM3

    Incandescent

    6V AC/DC YW1P-2TEQ5 A (amber), C (clear),G (green), R (red), S (blue),W (white), Y (yellow)

    Built-in incandescent lamp: LS-T

    12V AC/DC YW1P-2TEQ6

    24V AC/DC YW1P-2TEQ7

    ExtendedTransformer Type

    LED

    100/110V AC YW1P-2TEH2

    A (amber), G (green),PW (pure white), R (red),S (blue), W (white), Y (yellow)

    Built-in LED lamp: LSED-6

    200/220V AC YW1P-2TEM2

    115/120V AC YW1P-2TEH22

    230/240V AC YW1P-2TEM42

    Incandescent

    100/110V AC YW1P-2TEH5

    A (amber), C (clear),G (green), R (red), S (blue),W (white), Y (yellow)

    Built-in incandescent lamp: LS-T6

    200/220V AC YW1P-2TEM5

    115/120V AC YW1P-2TEH25

    230/240V AC YW1P-2TEM45

    DomeFull Voltage Without Lamp 250V AC/DC max. YW1P-2EQ0

    A (amber), C (clear),G (green), R (red), S (blue),W (white), Y (yellow)

    LED

    6V AC/DC YW1P-2EQ2

    A (amber), G (green),PW (pure white), R (red),S (blue), W (white), Y (yellow)

    Built-in LED lamp: LSED-

    12V AC/DC YW1P-2EQ3

    24V AC/DC YW1P-2EQ4

    110V AC/DC YW1P-2EQH

    230/240V AC/DC YW1P-2EQM3

    Incandescent

    6V AC/DC YW1P-2EQ5 A (amber), C (clear),G (green), R (red), S (blue),W (white), Y (yellow)

    Built-in incandescent lamp: LS-T

    12V AC/DC YW1P-2EQ6

    24V AC/DC YW1P-2EQ7

    DomeTransformer Type

    LED

    100/110V AC YW1P-2EH2

    A (amber), G (green),PW (pure white), R (red),S (blue), W (white), Y (yellow)

    Built-in LED lamp: LSED-6

    200/220V AC YW1P-2EM2

    115/120V AC YW1P-2EH22

    230/240V AC YW1P-2EM42

    Incandescent

    100/110V AC YW1P-2EH5

    A (amber), C (clear),G (green), R (red), S (blue),W (white), Y (yellow)

    Built-in incandescent lamp: LS-T6

    200/220V AC YW1P-2EM5

    115/120V AC YW1P-2EH25

    230/240V AC YW1P-2EM45

  • 8/11/2019 Aurora Appendix Product Reference

    21/23

    YW SeriesControl Units22

    Dimensions (Pilot Lights)

    29.8

    29.6

    24

    29.8

    29.6

    24

    63.3 9.5

    46.2 9.5

    Gasket

    Locking RingM3.5 Terminal Screw

    Gasket

    Locking RingM3.5 Terminal Screw

    Panel Thickness 0.8 to 6

    Panel Thickness 0.8 to 6

    29

    .8

    29.6

    24

    29.8

    29.6

    24

    63.3 10

    46.2 10

    Gasket

    Locking RingM3.5 Terminal Screw

    Gasket

    Locking RingM3.5 Terminal Screw

    Panel Thickness 0.8 to 6

    Panel Thickness 0.8 to 6

    15 5

    M3.5 Terminal Screw

    Panel Thickness 0.8 to 6

    Panel Thickness 0.8 to 6

    29

    .8

    29.6

    24

    29

    .8

    29 6

    24

    46.2 15.5

    Gasket

    Locking Ring

    Gasket

    Locking Ring

    M3.5 Terminal Screw

    Panel Thickness 0.8 to 6

    Panel Thickness 0.8 to 6

    63 3 15 5

    Gasket

    Locking RingM3.5 Terminal Screw

    29

    .8

    29 6

    24

    46.2 15.5

    Gasket

    Locking Ring

    29

    .8

    29.6

    24

    M3.5 Terminal Screw

    Flush

    Full Voltage

    Transformer Type

    Flush Marking Type

    Full Voltage

    Transformer Type

    Extended

    Full Voltage

    Transformer Type

    Dome

    Full Voltage

    Transformer Type

  • 8/11/2019 Aurora Appendix Product Reference

    22/23

    Catalog Dimensions in Inches and (mm)

    Type Symbol Amps A E F N C D

    2.38 .50 .03 .14 1.44 .54HRCI-CB CIF06B 1-30A

    (60.40) (12.70) (0.81) (3.50) (35.50) (13.80)

    HRCI-CB Industrial Ceramic Body Fuse CIF06Clip-In Mounting

    Form No. HRCI-CBPage 1 of 2

    Data Sheet: 4128

    Bussmann

    6-3-04 SB04168

    A

    C

    D E

    N F

    Catalog Symbol: CIF06B (1 - 30A)

    600Vac; 250Vdc

    Interrupting Rating: 200,000A RMS Symmetrical

    CSA C22.2 NO. 106-M92 (3-30A only)

    Industrial miniature fuse with offset blades for clip-in mounting.

    Ground ceramic body with plated endcaps.

    Provides both short circuit and overload protection.

    CIF06 fits the 30A SafeLOC fuseholder.

    Dimensional Data

  • 8/11/2019 Aurora Appendix Product Reference

    23/23

    HRCI-CB Industrial Ceramic Body Fuse CIF06Clip-In Mounting

    Bussmann

    Time/Current-Curves (Cat. No. CIF06)Peak Let-Through Curves (Cat. No. CIF06)

    10,0

    00

    1,0

    00

    100

    101

    1,000

    100

    10

    1

    .1

    CURRENT IN AMPERES

    T

    IMEIN

    SECONDS

    .01

    3 6 10

    15

    2530

    AMPERERATING2

    0

    1

    10

    100

    1,000

    10,000

    3 610

    15

    20

    25

    FUSE RATING (AMPERES)

    AMPERE2S

    ECONDS(I2t)

    100,000

    30

    Total I2t at 600V

    Total I2t at 460V

    Pre-Arcing I2t

    100

    101.1

    1,000

    100

    10

    1

    PROSPECTIVE CURRENT (SYM. RMS KA)

    PEAKCURRENT(KA)

    0.1

    61015202530

    AMPERE

    RATING

    3

    Energy Let-Through Curves (Cat. No. CIF06)

    Power Dissipation @ Rated Amps

    Catalog No. Watts

    1CIF06

    3CIF06B 1.8

    6CIF06B 1.5

    10CIF06B 3.4

    15CIF06B 2.4

    20CIF06B 3.2

    25CIF06B 3.6

    30CIF06B 3.6

    The only controlled copy of this Data Sheet is the electronic read-only version located on the BussmannNetwork Drive. All other copies of this Data Sheet are by definition uncontrolled.This bulletin is intendedto clearly present comprehensive product data and provide technical information that will help the enduser with design applications. Bussmann reserves the right, without notice, to change design or con-struction of any products and to discontinue or limit distribution of any products. Bussmann alsoreserves the right to change or update, without notice, any technical information contained in thisbulletin. Once a product has been selected, it should be tested by the user in all possible applications.