AU-Graphic Devices - Rehab

Embed Size (px)

Citation preview

  • 7/24/2019 AU-Graphic Devices - Rehab

    1/5

    Prof. and Head of the Department DATE : 22.07.2013

    Department of Electronics and Instrumentation Engineering REF: GRA/BLR/ANM/13-14/051

    Annamalai University

    Annamalainagar608 002.

    Dear Sir

    Sub : Quotation for Rehabilitative Lab Equipments.

    We are extremely thankful to you for the above enquiry for your department. In continuation to the same we

    are herewith enclosing our quotation along with Terms and condition and product brochure for your kind

    perusal.

    We request you to kindly go through the proposal and should you desire additional information / clarification

    feel free to contact us.

    We once again thank you for the enquiry and look forward to hear from you.

    Thanking you

    Yours Truly

    For Graphic Devices

    K.Srikanth

    Regional Director - South

  • 7/24/2019 AU-Graphic Devices - Rehab

    2/5

    QUOTATION - REHABILITATIVE LAB EQUIPMENTS

    Prof. and Head of the Department DATE : 22.07.2013

    Department of Electronics and Instrumentation Engineering REF: GRA/BLR/ANM/13-14/051

    Annamalai University

    Annamalainagar608 002.

    Sr no. Description QtyPrice in

    Rupees(INR)

    1 Rehabilitative Lab Equipment Setup

    Comprising of :

    a)LEGSYSWearable sensor for Gait analysis

    b)BALANSENSBalance and Mobility analysis

    c) Tread Mill

    d) BALANCE / Wobble Board

    e) BERA System

    a)LEGSysis easily portable and can be set up and utilized

    anywhere. Conduct gait tests at your office, in patients homes, or

    anywhere in between Wireless wearable system that is portable and easy to use

    Quickly analyze gait without the restraints of a gait

    laboratory, such as limited walking space

    Proprietary technology validated using state-of-the-art

    camera-based motion capture

    Automatically generated reports demonstrate patient

    progress toward measurable goals

    Sensors

    Sensor Size: 7.3 cm x 4.0 cm x 1.8 cm

    Weight: 30g (1.06 oz) g

    Sample Frequency: 50 Hz Battery Life: 4 hours

    Memory Capacity: 256 Mb (> 4 hours of data)

    Data Transmission: Bluetooth

    Software measures

    Basic Parameters

    Stride Length, Stride/Step Duration, Speed, Cadence

    Gait Cycle Timing

    Stance Percent, Swing Percent, Double Support Percent

    Stride-To-Stride Variability

    Speed, Stride Length, Stride Duration

    01 8,60,000-00

  • 7/24/2019 AU-Graphic Devices - Rehab

    3/5

    b)BalanSensuses two motion sensors and advanced algorithms

    based on human body mechanics. Run balance tests on the sidelines, in the clinicvirtually

    anywhere

    Wireless wearable system that is portable and easy to use

    Quickly analyze balance without the need for force plates

    Patient history allows you to assess return-to-baseline

    following injury

    Instant charting and analysis.

    Healthy normative data for comparison.

    Customizable report contents

    Sensors Sensor Size: 7.3 cm x 4.0 cm x 1.8 cm

    Weight: 30g (1.06 oz) g

    Sample Frequency: 50 Hz

    Battery Life: 4 hours

    Memory Capacity: 256 Mb (> 4 hours of data)

    Data Transmission: Bluetooth

    Provide over 17 measurements that include :

    Centre of Mass (COM) motion

    Anterior-Posterior motion

    Medial-lateral motion Ankle and hip angles

    Sway velocity, Sway area

    Reciprocal Compensatory Index (RCI)

    c) Tread Mill

    d) BALANCE / Wobble Board

    e) BERA System

    I - BERA Amplifier

    Operating Voltage : 8 Volts DC

    Out Put Pin Connection Details : BNC connector

    CMRR : 80 dB

    Gain : 1000

    Output : 1 V peak to peak per mV of input

    Enclosure :ABS

    Input :3 Electrode system

    Sensor Input Connector Details :Five Pin Female Connector

    Output :Compatible with DSO (with

    Average mode display)

  • 7/24/2019 AU-Graphic Devices - Rehab

    4/5

    II - BERA Audio Stimulator

    Operating Voltage :12 Volts DC

    Out Put Pin Connection Details :Phono Socket

    Gain :Adjustable

    Output :120 dB

    Enclosure :ABS

    Click Repetition Rate :0 Hz to 10 Hz

    Synch Output :50 milli sec pulse per click

    III - Power Supply

    Charger input :230V AC mains

    Battery :12V DC rechargeable (1.5 AH)

    Fuse :Fuse 500mA

    Enclosure :ABS

    Total in Rs. 8,60,000-00

    For Graphic Devices

    K.Srikanth

    Regional Director

  • 7/24/2019 AU-Graphic Devices - Rehab

    5/5

    TERMS & CONDITIONS

    VALIDITY OF THE OFFER

    ORDER

    :

    :

    90 Days from the date of Quotation

    Order has to be in the name

    PAYMENT TERMS : 100% advance along with Purchase Order

    TAXES : Price is inclusive of all taxes

    DELIVERY PERIOD : 46 WEEKS

    INSTALLATION : Free of cost

    WARRANTY : 12 months from date of installation or 13

    months from the date of shipment, whichever

    is earlier, subject to warranty conditions

    For Graphic Devices

    K.Srikanth

    Regional DirectorSouth