    INTRODUCTION

    The 2004 ed ition o f the Atw oo d Wa ter Heate r Service Manua l is a res ource c rea ted to

    help service technicians identify Atwood product by serial number, diagnose service

    prob lems and efficiently a nd effec tively proces s w arra nty claims.

    In 2003, Atwo od reloc a ted the S w itch, Thermosta t a nd EC O that w a s insta lled on the

    ba ck of comb ina tion 6 a nd 10 ga llon G a s/Elec tric Wa ter Heate rs. A do uble sw itch is

    now loc a ted inside the RV for convenience and a joint ECO a nd T-Stat is loc ated on

    the g as side of the w a ter heater. This lea ves only the relay a nd hea ting element on the

    backside of the water heater.

    Eac h of the ma nuals within this se ries offers a ge neral overview of the product a s w ell

    as more specific product information. For each product within the manual, you will

    find model identification, recommended tools and equipment, a sequence of

    operation, wa rnings , a nnual ma intenanc e proced ures , pa rts a nd troubles hootingguides , w arra nty proc edures, flat rate s ched ules , a nd replac ement pa rt reference

    charts.

    Due to the rapidly c hang ing persona l computer revolution w e ha ve plac ed

    troubles hooting information in a variety of place s to ma ke sure tha t the mos t a cc urate

    information is a vaila ble. The b es t pla ce to find the current informa tion a bo ut Atw oo d

    products is our website: www.atwoodmobile.com. At our website brochures may be

    do wnload ed, trouble s hooting guides review ed a nd the lates t information bulletins ca n

    be read. In addition all Atwood Authorized Service Centers are listed on our site,

    ac ces sible via an ea sy-to-use s earch system.

    S ervice for all Atwo od prod ucts is hand led out of our Roc kford loc ation. S hould youhave any q uestions reg arding our prod ucts or the informa tion c onta ined in this

    ma nua l simply dia l 1-800-825-4328. Be sure to have the Model a nd Serial Number whenyou call.

    Atwood Service Department

    Disclaimer: The data presented in this publication is obtained from the most reliable sources, and is believed to be accurate as of thedate of publication. Responsibility for typographical errors or omission of data cannot be assumed by the publishers.

  • 7/28/2019 Atwood Water Heater Service

    2/40

    2

    NOTES

    THIS PAGE INTENTIONALLY LEFT B LANK

  • 7/28/2019 Atwood Water Heater Service

    3/40

    3

    TABLE OF CONTENTS

    Atwood Water Heaters

    Atwood Letter 1

    Aftermarket Model Identification 4

    Pilot Models

    Ques tions 5Model Number Expla na tion /Fea tures 6

    Recommended Tools &Eq uipment 7

    G a s Thermos ta t C ontrols &P ilot Assemblies 8

    P ilot S eq uence of Opera tion 9

    P ilot &Ma in Burner 10

    Trouble S hooting G uide 11

    Engine Hea t Excha nge S ys tem /Afterma rket Hea ting Elements 12

    Bolt-In Heating Element, Thermostat &ECO /110 VAC Trouble Shooting Wiring Sc hematic 13

    Sc rew-In Heating Element, Thermosta t &ECO /110 VAC Trouble S hooting Wiring S chematic 14

    Electronic Ignition Models

    Ques tions 15

    Model Number Expla na tion /Fea tures 16

    Recommended Tools &Eq uipment 17

    DS I S eq uence of Opera tion 18

    Trouble S hooting G uide - Electronic Ig nition 19-20

    Informa tion G uide - Intermittent Ignition 21-22

    P otted Cha nnel C ircuit B oa rds /Therma l Cut Off Device /Thermos ta t 23

    Wiring S chema tics 24

    General Water Heater Information

    Ques tions 25

    Pressure Tempera ture Relie f Va lve /Water Hea ter Tank Corros ion /Atwood Clad Tank 26

    Flushing Ta nk /Winterizing Ins truc tions 27

    Wa ter Hea ter Terminology 28

    Warranty 29

    Warranty Procedures 29

    Return Goods Policy (RETURN ADDRESS) 30

    Flat Rate Schedule 31

    Pilot Water Heater Parts Breakdown 32-34Replacement Part Reference

    G10B, G10C /G610-3B, GH610-3 /G4SM /G6A-2, G6A-3, G6A-6, G6A-6P, G6A-7, G6A-7P /GC6A, GC6A-3,

    G C 6A-6, G C6A-7 /G H6-3, G H6-6, G H6-7 /G C6AA-7, GC 6AA-7P / GC 6AA-8, GC 6AA-8P / G610-3,

    GC 10-1, G C10-2, GC 10-2P /G C10A-2 /G C10A-2P /G 10-1, G10-1P, G10-2, G10-2P

    Electronic Ignition Water Heater Parts Breakdown 35-37Replacement Part Reference

    G610-3E, GH610-3E /GCH6-4E, GCH6-6E, /GC6A-7E /GC6AA-7E /GC6AA-8E /GC6AA-9E, GC6AA-10E

    G 6A-2E, G6A-3E, G6A-4E, G 6A-6E, G6A-7E, G6A-8E /G 6A-3E, GH6-3E /G H6-4E, GH6-6E, G H6-7E,

    GH6-8E /G CH6A-7E, GC H6A-8E, GC H6A-9E /G CH6A-10E /

    GCH10A-2E, GCH10A-3E /GCH10-4E /G10-1E /GH10-2E, GH10-3E / GC10-1E, GC10-2E /GC10A-2E /

    GC 10A-3E /G C10A-4E

    Service Tank Kit Part Numbers 38

    Marine Water Heater Parts Breakdown 39

    Atwood Training Tapes and Manuals ORDER BLANK

  • 7/28/2019 Atwood Water Heater Service

    4/40

    4

    Aftermarket Gas Water HeatersIncludes Doors & Switches (when appropriate)

    G6A-7 ----------------------------------6 gal. w/pilot

    GC6AA-8 ------------------------------6 gal. combo w/pilot

    GC6AA-10E ----------------------------6 gal. electronic gas combo

    GCH6A-10E----------------------------6 gal. electronic gas combo w/heat exchangeG6A-8E --------------------------------6 gal. electronic

    GH6-7 ----------------------------------6 gal. w/pilot, heat exchange

    GH6-8E --------------------------------6 gal. electronic w/heat exchange

    G10-2----------------------------------10 gal. w/pilot

    GC10A-2------------------------------10 gal. combo

    G10-3E--------------------------------10 gal. electronic

    GC10A-4E ----------------------------10 gal. electronic combo

    GCH10A-4E --------------------------10 gal. electronic combo w/heat exchange

    Marine Water HeatersEHM6-4WFHX ------------------------4 gal. marine, front heat exchange & special hook-upEHM6-SMFHX ------------------------6 gal. electric marine w/heat exchange

    H6-FHX --------------------------------6 gal. marine special

    EHM6-ATC ----------------------------6 gal. marine, heat exchange & temp. control

    EHM6-SMSS --------------------------6 gal. marine, rear heat exchange & special hook-up

    EHM11-SSDHXT --------------------6 gal. marine, stainless steel dual heat exchange tube

    EHM11-SMFHX --------------------11 gal. electric marine w/heat exchange

    EHM11-SST--------------------------11 gal. electric, heat exchange stainless steel tank

    H11-FHX------------------------------11 gal. marine special

    EHPM10 ------------------------------11 gal. electric marine w/special tube

    EH-20----------------------------------20 gal. electric marine w/heat exchange

    E20 ------------------------------------20 gal. electric marine

    M arine International Water HeatersEHM6-220-FHX ----------------------6 gal. marine, heat exchange, 220 volts

    EHM6-220SST ------------------------6 gal. marine, heat exchange, 220 volts, stainless steel housing

    EHM6-220-FHX ----------------------6 gal. marine, heat exchange, 220 volt, 1000 watt element

    EHM11-220--------------------------11 gal. marine, heat exchange, 220 volts

    EHM11-220SST --------------------11 gal. marine, heat exchange, 220 volts, stainless steel housing

    EHM11-220SS-4WFHX ----------11 gal. marine, heat exchange, w/special hook-up

    EHM11-220SS-IMFHX ------------11 gal. marine, heat exchange, 220 volt, 1000 watt element

    EH20-220 ----------------------------20 gal. marine, heat exchange, 220 voltsE20-220 ------------------------------20 gal. marine, 220 volts

    European Water HeatersEURI6A-6E ----------------------------6 gal. International Electronic 3-bar valve

    EURIH6-6E ----------------------------6 gal. International Electronic w/heat exchange

    EURICH6-6E --------------------------6 gal. International Electronic Combo w/heat exchange

  • 7/28/2019 Atwood Water Heater Service

    5/40

    5

    PILOT M ODELS

    QUESTIONS

    The following questions should be answered during this portion of the manual:

    Are the Robertsha w a nd White Rodg ers thermosta t ga s c ontrol valves inter-cha ngea ble?

    What is the minimum ga s press ure required for proper wa ter heater opera tion?

    Where on the wa ter heater ga s c ontrol ca n gas press ure be tested ?

    Ca n the pilot flame b e ad justed?

    Wha t is minimum millivolt output of the thermoc ouple req uired for proper ga s c ontrol ope ration?

    How ca n you test a thermoco uple?

    How tight should the thermoco uple co nnection be a t the ga s c ontrol?

    What is an E.C. O., where is it loc a ted a nd w ha t is its function?

    What is a proper ma in burner a ir shutter ad justment?

    What is the proper control a nd ma in burner a lignme nt?

    How c an you ea sily chec k the ca libration of a c ontrol?

  • 7/28/2019 Atwood Water Heater Service

    6/40

    6

    Atwood 6 and 10 gallon Pilot Water HeatersAtwood water heaters are designed and approved for use only in recreation vehicles (travel trailers, 5th wheels,

    moto r homes , etc .). They a re offered in two s izes : 6 and 10 ga llon c a pa cities .

    TYPE OF GAS IGNITION -

    This unit is ignited outs ide of the tra iler by a ma tc h, piezo ignitor or other ignition device . The w a ter

    temperature is a djusta ble at the thermosta t c ontrol.

    EXPLANATION OF MODEL NUMBER:

    Pilot Models

    G C H 6 AA - 7 P

    P ilot Relig ht

    Version

    Type of hea ting element

    (G C _ A - _ = bo lt on, G C _ A A-_ = s crew in)

    Gallon capacity (6 or 10)

    Engine Heat Exchange

    Combination gas and 110 VAC electric

    Propane Ga s

    NOTE: When replac ing the e lement o n a co mbination ga s/110 VAC unit, a lw a ys chec k the ba ckof the hea ter for the type o f element it has . It will either be a bo lt-on or sc rew -in

    element. They a re no interchang ea ble.

    FEATURES All units operate on propane gas.

    A hea t excha nge o ption is a vaila ble for motor homes. The wa ter heater tank must ha ve fac tory eq uipped

    heat excha nge tubes welded on it a lrea dy. They ca nnot be a dde d later. A new wa ter heater tank with this

    option is the only way to obtain this feature. Skin mounting allows the water heater to be hooked up with plumbing and electrical before the sidewall is

    erected.

    The ta nk has a clad aluminum lining tha t protects a ga inst c orrosion and does not need to be repla ced on

    a yearly or more frequent basis like anode rods do. A more detailed explanation of cladding is found in the

    ba ck of this ma nua l.

    95% of all servicing can be done on the outside of the water heater. 110 VAC heating components are the

    exception since they are located on the back of the water heater inside the trailer.

    A flush flange is a vaila ble for all mod els. This ma kes the a cc es s do or flush w ith the trailer sidew a ll.

    There a re multiple prote ct ion fea tures in the form of a press ure-temp era ture relief va lve, a limit sw itc h in

    the gas thermostat and an externally sealed combustion chamber.

    On combina tion wa ter heaters, the ga s mod e a nd the 110 VAC hea ting mode c an be o pera ted a t the same

    time since each mode has its own thermostat.

    Both the six and ten gallon units have the lightest weight in the industry.

    On a ll tra ilers purcha se d a fter J une 1, 1997 Atw ood Limited Wa rra nty is for a period of tw o ye a rs. This

    includes all rea sona ble la bor cha rges .

    We ha ve 650+ S ervice Centers throughout the United S tates .

  • 7/28/2019 Atwood Water Heater Service

    7/40

    7

    Recommended Tools and Equipment

    U-Tube Manometer - This is the mo st a cc ura te d evice for meas uring g a s p ress ure. If you use a dial-typema nometer, it should be ca librated period ica lly w ith this type o f ma nometer.

    Thermostat Wrench - This tool a llow s for eas ier and sa fer remova l of the ga s thermos tat control. Ana djusta ble version for d ifferent size co ntrols is a vailab le through mo st RV distributors o r you ma y fa brica te o ne

    from a ngle iron. We do not reco mmend using a pipe w rench b eca use it may da mag e the co ntrol caus ing it to

    go out of ca libration.

    Multi-meter - This is the m os t versa tile me ter and will tes t AC vo lta ge a nd c ontinuity. A co ntinuity tes t ca n beused to test for a blown E.C.O. on a g as control.

    Magnet Assembly Thermocouple Tester - This a ss embly ca n be o bta ined a t an electronics or hardw a re sto reThis s a me a ss embly ca n also b e removed from a Rob ertshaw co ntrol. It will verify if a thermoco uple is go od .

    For tes ting, s crew a thermoc ouple into the tes ter, hea t the thermocouple for 25 se co nds and then press the

    plunger do wn. If the plunger pops up in les s tha t 25 seco nds , the thermocouple is fa ulty.

    Common Hand Tools - 1/8 a nd 1/4 nut drivers, open e nd w renches , flat blad e a nd P hillips sc rew drivers.

    Leak Test Solution - A solution that bubbles when applied to gas fittings or connections showing when a gasleak is present.

    THERMOSTAT WRENCH

    76543210

    1234567

    Manometerconnection

    Correctwa terlevel

    Fill here

    U-TUBE M ANOMETERwith 1/8 pipe nipple

    M ULTI-M ETER TO TESTAC VOLTAGE AND CONTINUITY

    MAGNET ASSEMBLY TO TESTTHERMOCOUPLE

  • 7/28/2019 Atwood Water Heater Service

    8/40

    8

    Gas Thermostat Controls and Pilot Assemblies

    Only tw o ma kes of ga s c ontrols ha ve been used on our pilot mod el water heaters. They a re the Robertsha w

    Unitrol a nd White Rod ge r (formerly J a de or ITT).

    The Ro be rtsha w c ontrol ca me in tw o d ifferent s izes of g a s inlets: 3/8inverted fla re and 3/8 N.P.T. The

    inverted inlet c ontrol is no longer a va ila ble. Therefore, the w a ter hea ter ga s line c onnec tion w ill ha ve to be

    mod ified to 3/8 N.P.T. in order to us e the c urrent R ob ertsha w c ontrol.

    The White R od ge r co ntrol is the va lve w e a re using o n a ll prod uct ion to da y. Formerly it had a 3/8N.P.T.

    inlet. Now it is only a va ila ble w ith a 1/4inlet. This improvem ent e limina tes the a da pter fitting into the c ontrol

    a llow ing the use o f only a s ingle 45 de g ree elbow (3/8fla re x 1/4N.P.T.). If yo u a re replac ing a current 1/4

    inlet mo de l control w ith a ea rlier mod el 3/8inlet c ontrol you ma y ha ve in stoc k, the a da pter fitting tha t

    mates the control and elbow fitting is still available.

    Although the controls appear quite different in size, the White Rodger and Robertshaw control are

    intercha nge a ble. Their ma nifolds w ill bo th line up w ith the b urner tube prope rly.

    Bo th controls have a port to test ga s press ure through the va lve. This ca n be ac complished by removing the

    co ver sc rew a nd inserting a 1/8 pipe nipple. After atta ching your ma nomete r hose to this fitting, the

    ma nometer s hould reg iste r 10 W.C . through the valve w hile it is opera ting.

    There a re tw o m a in pilot a ss emb lies that you w ill encounter in the field.

    The first is a n ea rlier mode l Robertsha w pilot a ss emb ly w ith a 1/4pilot g a s line tha t mounted on the left

    side of the ma in burner.

    The c urrent pilot is the J a de a ss emb ly w ith a 1/8pilot g a s line a nd it mounts on the right s ide of the ma in

    burner.

    The Rob ertsha w pilot is no long er ava ila ble and the J a de pilot must b e sub st ituted. When insta lling a J a de

    a ss embly in pla ce of a Robertshaw as semb ly, if there is not a loca tion on the right s ide of the ma in burner to

    mount the J a de pilot, a new burner that ha s the proper mounting holes w ill ha ve to b e purcha sed .

    Note: The size of the ga s line do es not ha ve

    any affect on the size of the pilot flame. Only

    the gas pressure and pilot orifice regulate the

    height of the pilot flame.

    ROBERTSHAW UNITROL

    3/8 Inverted inlet3/8 N.P.T. outlet(no longer available)

    3/8 N.P.T. inlet3/8 N.P.T. outlet

    WHITE RODGERS (JADE, ITT)

    3/8 N.P.T. outlet(no longer available)

    1/4 N.P.T. inlet3/8 N.P.T. outlet(replaces all Robertshaw

    and J ade controls)

    JADE ROBERTSHAW(obsolete, replace with J ade)

  • 7/28/2019 Atwood Water Heater Service

    9/40

    9

    Pilot Sequence of Operation

    PILOT OPERATION

    Gas Pressure 11 W.C. to control is necessary. Set with two gas appliances running.

    Gas Control supplies gas to pilot orifice when control ON/OFF pilot knob is held at pilot position.

    Pilot Orifice meters gas to heat thermocouple. Flame should be high enough to engulf thethermocouple.

    Thermocouple generates millivoltage to the gas controls magnet assembly.

    Magnet when it receives 12 millivolts or more it allows gas to flow freely to pilot withoutholding pilot knob.

    E.C.O. passes millivolts through the gas control and back to thermocouple. Tripspermanently open if water temperature exceeds 190F.

    MAIN BURNER OPERATION

    Gas Control supplies gas to main burner when control knob is set to ON position and thetemperature lever is set to desired temperature after pilot is lit.

    Ma in Burner Orifice meters gas through burner tube.

    Ma in Burner pilot ignites gas when it reaches end of this tube. Flame height adjusted by sliding airshutter. Ideal setting is 1/4 way open (.20 ). Flam e s hould b e prima rily blue w itha tra ce of yellow.

    Temperature Knob setting of knob determines burner cycle and water temperature. Temperature range is70F - 140F.

    Pilot Flame

    Thermocouple

    ON/OFF Pilot Knob

    Air Shutter

    ONE SHOTE.C.O. 1 90 Gas Inlet

    11" W.C.Pressure

    JADE CONTROL SYSTEM

    Temperature Lever

    Pilot Orifice (i nside)

  • 7/28/2019 Atwood Water Heater Service

    10/40

    10

    Pilot and Main Burner

    Pilot AdjustmentOnly the gas pressure, gas valve and the pilot orifice regulate the height of the pilot flame. Early model gas

    co ntrols ha ve a pilot a djustm ent s crew, b ut this sc rew has very little effect on the p ilot. The pilot

    a djustme nt has bee n removed from the c urrent White Rod ge r control. The fla me s hould b e high eno ugh to

    engulf the thermoco uple a t a ll times . A pilot flame a ny larger co uld blow the E.C .O. in the g a s co ntrol. This

    is typically the result of enlarging the pilot orifice hole with a pin or similar item. For further correctivemeasures, refer to the trouble-shooting guide.

    M ain Burner AdjustmentThe g a s press ure, a ir shutter clea nliness of the burner tube a nd o rifice regula te the ma in burner fla me. The

    main burner flame should be mainly blue with a trace of yellow and fairly quiet. If it is not, adjust the gas

    press ure to 11 W.C. , ens ure tha t the ma in burner air shutter is 1/4 w a y op en a nd verify tha t the ma in

    burner flame spreader is square to the end of the main burner. For further corrective measures, refer to the

    trouble-shooting g uide .

    Main Burner AlignmentThe ma nifold a nd ma in burner sho uld b e a s perfectly aligned a s po ss ible. In other w ords, the g a s va lve

    sho uld b e rotated a t the sa me a ngle as the ma in burner tube. If it is not, rota te the ga s c ontrol a nd/or the

    orifice holder so that the orifice disperses gas straight down the center of the burner tube. If the valve must

    be ba cked off any, check for wa ter lea ks at the coupling the c ontrol screws into before you operate the

    wa ter heater.

    Pilot Flame

    Thermocouple

    On/Off Pilot Knob

    Air Shutter

    Temperature Lever

    Flame Spreader

    Burner Tube

    GasValve

    OrificeHolder

    MainBurnerTub

    e

    (orientation found in water heater)

  • 7/28/2019 Atwood Water Heater Service

    11/40

    11

    Guides are only intended for use on Atwood products by service technicians who have successfully completed

    Atwood training. This guide s hould be use d in conjunction with the app ropriate Instruction Manua l provide d w ith theprod uct and any a pplica ble Industry stand ards. This is not intended to be a c omplete list. P lea se d irect q uestions

    co ncerning s ervice of Atwoo d products to 800-825-4328 before proceeding.

    CAUSE SOLUTION

    PILOT OUTAGEGas pressure incorrect --------------------------Set pressure to a minimum of 11 W.C. with two or more appliances runningBlocked U tube --------------------------------Remove obstructionImproper main burner alignment --------------Re-align main burner and main burner orifice holder and gas valveImproper air adjustment ------------------------Adjust main burner air shutter approximately 1/4 openWeak thermocouple------------------------------Replace thermocouplePoor pilot flame ----------------------------------Clean or replace pilot orificeWeak gas control magnet ----------------------Replace gas controlDefective E.C.O. in control ----------------------Replace gas control and check the pilot flame. It should be high enough to engulf

    the thermocouple at all times.PILOT OUTAGE WHEN BUTTON OR KNOB IS RELEASED

    Thermocouple not hot --------------------------Hold button or knob for 30 seconds before releasingThermocouple loose ----------------------------Tighten connection at gas controlWeak thermocouple------------------------------Replace thermocoupleWeak gas control magnet ----------------------Replace gas controlDefective E.C.O. in control ----------------------Replace gas control

    MAIN BURNER WILL NOT IGNITEBlocked main burner orifice --------------------Clean or replace orificeMain burner flame spreader mis-alignment --Square flame spreader to end of main burnerBlocked main burner ----------------------------Remove blockageImproper air adjustment ------------------------Adjust main burner air shutter approximately 1/4 openBlocked U tube --------------------------------Remove blockageGas control out of calibration ------------------Replace gas control

    ERRATIC M AIN BURNER FLAMEImproper gas pressure--------------------------Set inlet pressure to a minimum of 11 W.C. with two or more appliances runningImproper air adjustment ------------------------Adjust main burner air shutter approximately 1/4 openPartial blockage of main burner ----------------Remove blockagePartial blockage of main burner orifice--------Clean or replace orificeFlame spreader misaligned----------------------Re-align spreader or replace main burnerBlockage in U tube ----------------------------Remove blockagePoor gas supply----------------------------------Replace gas supplyExhaust grille blocked --------------------------Remove blockageImproper main burner alignment --------------Re-align main burner, main burner orifice holder and gas valve

    SMOKING AND SOOTINGGas pressure incorrect --------------------------Set pressure to a minimum of 11 W.C. with two or more appliances runningPoor gas supply----------------------------------Replace gas supply

    Improper pilot flame ----------------------------Clean or replace pilot orificeImproper air adjustment ------------------------Adjust main burner air shutter approximately 1/4 openFlame spreader mis-aligned --------------------Re-align or replace main burnerBlocked main burner ----------------------------Remove blockageImproper main burner alignment --------------Re-align main burner, main burner orifice holder and gas valveBlocked U tube --------------------------------Remove blockage

    INSUFFICIENT WATER TEMPERATURETemperature selector out of place--------------Re-set to desired positionBypass levers improperly positioned ----------Reposition leversImproper air adjustment ------------------------Adjust main burner air shutter approximately 1/4 way openPartial main burner blockage ------------------Remove blockageImproper main burner adjustment ------------Re-align main burner and main burner orifice holderFlame spreader mis-aligned --------------------Re-align or replace main burnerBlocked U tube --------------------------------Remove blockage

    Pilot Water Heater

    TROUBLE SHOOTIN G GUIDE

    Effec tive: 5/26/98

  • 7/28/2019 Atwood Water Heater Service

    12/40

    12

    Engine Heat Exchange System

    The engine hea t excha nge s yste m a llow s a moto r home to hea t the w a ter while traveling. This c onvenient

    option allows you to arrive at your destination with hot water. Operating a pilot or electronic water heater on

    ga s w hile in trans it is a da ngerous pra ctice.

    This s ystem c onsists o f a U-sha ped a luminum tube tha t is a ttac hed to the o utside o f the tank with welds. S AE

    hoses are attached to both ends of this tube and are spliced into the engine coolant system.

    When the engine is running, the hot coolant flows past the tank through this tube and by means of heat

    trans fer through the w elds, hea ting the w a ter. The des ign of this sys tem w ill not a llow the w a ter to rea ch a

    bo iling p oint. It will typica lly hea t the w a ter to a bo ut 130 F. in ab out 2-3 hours of d riving.

    Customer supplied SAE 053 A type"E" hose clamp

    or evuivalent

    Heat Exchanger Tubes

    Annualar Grove

    Heat ExchangerTubes

    Coolant System Hose(5/8" dia. SAE 20R3or equivalent)

    Customersupplied tee

    Temperatures produce d by these heating elements

    ca n exc eed the 190F. limit of t he EC O on pilot m od el

    ga s c ontrol va lves. This g a s c ontrol valve conta ins a

    one-shot ECO. When this ECO blows, the control is

    completely non-functional and must be replaced.

    THIS WILL BE A NON-WARRANTABLE SITUATION.

    When Aftermarket hea ting e lements a re inserted

    into the drain plug, customers are more prone not

    to flush their tanks. Not flushing the ta nk

    a cc elerates tank corrosion on b oth our pilot a nd

    electronic ignition water heaters creating a situation

    where the tank may have to b e replac ed. THIS WILL

    BE A NON-WARRANTABLE SITUATION.

    Aftermarket Heating Elements

    WARNINGEXPLOSION / BURN INJURY

    Aftermarket hea ting elements ca n la ck critica l sa fety controls.

    Use of these devices ca n lea d to a n out of control heating of wa ter tank and a

    ca tas trophic w et side explosion.

    YOU DO NOT NEED AN AFTERMARKET HEATING ELEMENT ON AN ATWOOD WATER HEATER. THE USE OF AFTERMARKET HEATINGELEMENT DEVICES MAY ALSO RESULT IN DAMAGE TO COMPONENTS OR WATER HEATER. Atwoods w ritten wa rranty s tates

    - failure or damage resulting from any alteration to our water heater is the owners responsibility. ANY

    ALTERATION, LIKE THE ADDITION OF AN AFTERMARKET HEATING ELEMENT DEVICE, WILL VOID THE WARRANTY.

  • 7/28/2019 Atwood Water Heater Service

    13/40

    13

    Ground

    Switch

    Element

    Fixed Thermostat

    Manual ResetHigh TemperatureLimit Switch

    ( 3 )-GREEN

    ( 1 )-BLACK BLACK

    ( 2 )-WHITE BLACK

    Hot Lead

    Ground Lead

    Common Lead

    Early mo de l wa ter hea ters w ith 110 VAC hea ting

    capacity used a bolt-on heating element and a one

    piece thermos ta t/E.C.O..

    This 110 VAC sy ste m ha s a n a djusta ble rec ta ngular

    thermosta t that is surfac e mounted to the inner tank

    a nd reta ined b y a ste el clip. The tempe rature settings

    a re HI, MEDIUM, a nd LOW. If the thermos ta t is

    ma king unobs tructed conta ct with the aluminum tank

    and it is set to the HI position, it should heat the water

    to 130 F. It w ill take longer to heat a tank of wa ter on

    electric than gas.

    The hea ting e lement w a s cha nged in 1996 from

    1500W to 1400W bringing the amperage draw down

    to 12.7 amps and allowing more cushion for the

    15 amp circuit breaker that is normally placed in line.

    This c hange ad ds a few minutes to the hea ting time.

    There a re 110 VAC a fterma rket c onvers ion kits b eing

    offered by distributors in w hich the hea ting e lement is

    screwed into the tank where the drain plug is located.

    We d o no t offer suc h a kit. Our kit includes the ta nk

    with the 110 VAC components already installed in it.

    In the case where the 110VAC portion of the water

    heater is not heating water, the following diagnostic

    steps a nd repa irs should b e investiga ted:

    Turn POWER OFF to the appliance beforeremoving junction box cover.

    Perform the following steps with POWER ON towater heater.

    1. Verify switch-A is in ON position.

    2. Insure there is 110VAC to the unit (mea sure

    voltage across the black and white lead to the

    a pplia nce with P OWER ON). If none, tra ce w iring

    back and make appropriate wire repair.

    Perform the following steps with POWER OFF towater heater.

    3. ECO Re-set B utton-D should b e depress ed.

    4. Check for continuity betw een sc rew-B and sc rew -

    C of thermos ta t. If none, replac e thermosta t.

    5. If w a ter is insufficiently hot, chec k ECO /

    Thermos ta t-E is o n high.

    6. Verify a g ood wire co nnection betw een thermosta t

    sc rew -C a nd hea ting element sc rew-G . Co rrect if

    necessary.

    7. There should b e c ontinuity b etw een hea ting

    element screw -G a nd sc rew -F. If none, element is

    ba d a nd s hould b e repla ced . Do not over-tighten

    self-tapping screws when installing new element.

    8. Check for continuity between element screw-G

    and flange of element. If there is, element has

    shorted. Element should be replaced.

    9. Verify ground c onnec tion.

    NOTE: Heating element can be operated on an emptytank for a limited period of time before it self destructs.

    BOLT-INHeating Element, Thermostat & ECO

    110VAC Trouble-ShootingWiring Schematic

    Temperature

    Adjustment Dial

    ECORe-Set

    Button

    UP

  • 7/28/2019 Atwood Water Heater Service

    14/40

    14

    Current produc tion w a ter hea ters w ith the 110 VAC

    heating option use a screw-in heating element, asepa rate pre-set thermostat and a sepa rate ECO.

    The s crew -in hea ting element is rated a t 1400 wa tts

    just like the bolt-on element. It is an incalloy element

    and can be run for a limited amount of time in a dry

    tank without shorting out.

    C AUTION: If the he a ting element is a llowe d t o run

    with a dry tank, allow the tank to cool down for 2-3

    hours before adding water. Adding water before

    the tank cools sufficiently could collapse the tank.

    The thermosta t and EC O are pre-set s urfac e-mounted

    disc s. The thermostat is s et at 140 F and is the samethermosta t used on the ga s side of the electronic

    ignition w a ter heate rs. The ECO is a ba ckup

    thermostat and will trip if the thermostat fails and the

    wa ter temperature exceeds 170 F.

    When the 110VAC portion of the water heater is not

    heating wa ter, the follow ing d iag nostic steps andrepairs should be investigated:

    Turn POWER OFF to the appliance before removing

    junction box cover.

    Perform the following steps with POWER ON towater heater.

    1. Verify s w itc h is in ON po s ition.

    2. Insure there is 110VAC to the unit (mea sure

    voltage across the black and white lead to the

    appliance with POWER ON). If none, trace wiring

    back and make appropriate wire repair.

    Perform the following steps with POWER OFF towater heater.3. Manual reset ECO high limit switch-A should be

    depressed . C heck for continuity betw een

    TERMINAL B and TERMINAL C of ECO.

    4. Check for continuity between TERMINAL D and

    TERMINAL E of thermostat. If there is none, replace

    thermostat.

    5. If water is insufficiently hot, insure thermostat is

    flush with tank.

    6. Verify a g ood w ire c onnec tion be tw een ECO

    TERMINAL-C a nd hea ting element TERMINAL-F.

    Co rrect if neces sa ry.

    7. Check for continuity between heating element

    TERMINAL-F and TERMINAL-G. If none, element is bad

    and should be replaced. Do not over-tighten self-

    tapping screws when installing new element.

    8. There s hould NOT BE CONTINUITY betw een element

    screw-G and flange of element. If there is, element

    has shorted. Element should b e repla ced .

    9. Verify g round c onne ct ion.

    NOTE: Heating element ca n be operated on an emptytank for a limited period of time before it self destructs.

    Ground

    Switch

    Element

    Fixed Thermostat

    Manual ResetHigh TemperatureLimit Switch

    ( 3 )-GREEN

    ( 1 )-BLACK BLACK

    ( 2 )-WHITE BLACK

    Hot Lead

    Ground Lead

    Common Lead

    SCREW-INHeating Elem ent, Thermostat & ECO

    110VAC Trouble-ShootingWiring Schematic

    UP

    G C DF B E

    A

  • 7/28/2019 Atwood Water Heater Service

    15/40

    15

    ELECTRONIC IGNITION MODELS

    QUESTIONS

    The following questions should be answered during this portion of the manual:

    What is minimum ga s press ure for proper w a ter heater operation?

    Where on the ga s s olenoid valve ca n ga s pressure be tested ?

    What is the minimum volta ge nee ded for opera tion?

    Wha t is the prope r w iring hoo k-up for the w a ter hea ter circ uitry?

    C a n the Circuit B oa rd Tes ter be use d on both Fenwa l a nd Cha nnel circuit bo a rds ?

    How c an the C ircuit Boa rd Tester be used to chec k a " flying lea d" circuit boa rd?

    What co nditions c a n ca use tra cks on the bac k of the circuit boa rd to blow?

    What is a proper ma in burner a ir shutter a djustm ent?

    Wha t is the function of the thermal cut-off?

  • 7/28/2019 Atwood Water Heater Service

    16/40

    16

    Atwood 6 and 10 gallon Electronic Ignition Water HeatersAtwood water heaters are designed and approved for use only in recreation vehicles (travel trailers, 5th wheels,

    moto r homes , etc .). They a re offered in two s izes : 6 and 10 ga llon c a pa cities .

    TYPE OF GAS IGNITION -

    This unit is ignited ins ide of the trailer by a remote ON/OFF sw itch. The wa ter tempera ture is preset a t 140 F.

    EXPLANATION OF MODEL NUMBER:

    Electronic ModelsG C H 6 A - 9 E

    Elec tronic Ignition

    Version

    Type of hea ting element

    (G C _ A - _ _ = bolt on, G C _ A A-_ _ = s c rew in)

    Gallon capacity (6 or 10)

    Engine heat excha nge

    Co mbination ga s a nd 110VAC electric

    Propane Ga s

    NOTE: When replac ing the e lement o n a co mbination ga s/110 VAC unit, a lw a ys chec k the ba ckof the hea ter for the type o f element it has . It will either be a bo lt-on or sc rew -in

    element. They a re not interchang ea ble.

    FEATURES All units operate on propane gas.

    A pre-se t thermosta t se t for 140 F. An afterma rket retro-fit a djusta ble thermos ta t is a vaila ble and

    ad justable from 110 to 150 F.

    A heat excha nge o ption is a vaila ble. The w a ter heater tank must have fa ctory eq uipped hea t excha nge

    tubes w elded on it a lrea dy. They ca nnot be a dd ed late r. A new w a ter heater ta nk w ith this fea ture must b e

    insta lled to use the hea t excha nger.

    Skin mounting allows the water heater to be hooked up with plumbing and electrical before the sidewall is

    erected.

    This hea ter has a co mpa rab le, if not s uperior, a node type protec tion for the ta nk. The ta nk is m a nufac tured

    with a c lad aluminum lining tha t protects a ga inst c orrosion but does not need to b e replac ed yea rly a s a n

    anode rod. A more detailed explanation of cladding is found in the back of this manual.

    95% of a ll se rvicing is do ne on the o utside of the w a ter heate r. 110 VAC hea ting c ompo nents a re the

    exception. Since they are located on the back of the water heater inside the trailer.

    A flush fla nge is a vaila ble for all mod els. This m a kes the a cc es s do or flush w ith the s idew a ll.

    There a re multiple prote ct ion fea tures in the form of a press ure-temp era ture relief va lve, a limit sw itc h in

    the gas thermostat and an externally sealed combustion chamber.

    Both the six and ten gallon units have the lightest weight in the industry.

    On a ll tra ilers purcha se d a fter J une 1, 1997 the Atw ood Limited Wa rra nty is for a period of tw o ye a rs. This

    includes all rea sona ble la bor cha rges .

    We ha ve 700+ S ervice Centers throughout the United S tates .

  • 7/28/2019 Atwood Water Heater Service

    17/40

    17

    Recommended Tools and Equipment

    U-Tube Manometer - This is the mo st a cc ura te d evice for meas uring g a s p ress ure. If you use a dial-typema nometer, it should be ca librated period ica lly w ith this type o f ma nometer.

    Multi-meter - This is the m os t versa tile me ter and will tes t co ntinuity a nd 12VDC . Thes e tes ts w ill a llow one toverify voltag e problems or faulty co mponents. The entire e lectronic sys tem c an be teste d with this meter.

    Circuit Board Tester - The tes ter is c a pa ble of testing a ny of the circuit bo a rds (Fenwa l a nd C hannel mode ls)that we have used on our water heaters. It is a simple table top device that will diagnose the following items on

    a circuit boa rd: pow er circuit, s ense circuit, s pa rk ge neration a nd the lock-out mode. For use on c ircuit boa rds

    with a flying lea d co nnection, splice a wire into the b la ck w ire o f the tes ter harness with a 1/4 male terminal on

    the free end .

    Common Hand Tools - 1/8 a nd 1/4 nut drivers, open e nd w renches , flat blad e a nd P hillips sc rew drivers.

    Leak Test Solution - A solution that bubbles when applied to gas fittings or connections showing where a gasleak is present.

    7654

    32101234567

    Manometerconnection

    Correctwa terlevel

    Fill here

    MULTI-M ETER TO TESTCONTINUITY & VOLTAGE

    U-TUBE M ANOM ETERwith 1/8 pipe nipple

    CIRCUIT BOARD TESTERMPD 32779

  • 7/28/2019 Atwood Water Heater Service

    18/40

    18

    DSI Sequence of Operation

    Gas Supply 11 W.C to solenoid valve is necessary

    12VDC Battery Voltage source to water heateror filtered sideof Convertor

    ON/OFF Switch It supplies 12VDC to water heater

    Thermal Cut-Off A one shot heat sensing fuse thats normally closed and sends power to the thermostat.When tripped by excessive heat (190F), (i.e. blocked burner or flue tube) it cuts power to

    the circuit board and shuts down ignition.

    Thermostat A normally closed non-adjustable temperature switch that sends current to the circuitboard. It opens when the water temperature reaches approximately 140F.

    Circuit Board The next step is the direct spark ignition system. For a period of 6-8 seconds the circuitboard will send voltage to both the gas solenoid valve and the electrodes. If ignition doesnot occur, the board goes into a lock-out condition and the non-ignition light illuminated atthe ON/OFF switch.

    E.C.O.A normally closed safety temperature switch thatsends voltage to solenoid valve. The switch opens ifthe water temperature exceeds 180F.

    Gas ValveThe dual solenoid valve that opens and sends gas toelectrodes when a minimum of 10.5 VDC is applied to it.

    ElectrodesCreates a spark to ignite gas. If the electrodes do notsense a flame in 6-8 seconds, a signal is sent to theboard to shut the gas valve down and the system goesinto safety lock-out.

    NOTE: If this situation exists, the ON/OFF switch must beturned off and back on again.

  • 7/28/2019 Atwood Water Heater Service

    19/40

    19

    Guides are only intended for use on Atwood products by service technicians who have successfully completed

    Atwood training. This guide s hould be used in co njunction with the a ppropria te Instruction Manua l provide d w ith the

    product and any a pplica ble Industry stand ards. This is not intended to be a c omplete list. P lea se direc t ques tions

    co ncerning s ervice of Atwo od products to 800-825-4328 before proceeding.

    CAUSE SOLUTION

    WAT ER HEAT ER L OCK OUT - SPARK PRESENT BUT NO GAS

    Gas pressure incorrect ------------------------------------------Set inlet pressure at a minimum 11 W.C. with two or more gasappliances running

    Low voltage--------------------------------------------------------Correct power supply - 10.5 VDC minimumBlocked main burner tube --------------------------------------Clean burner tube

    Blocked main burner orifice ------------------------------------Clean or replace orificeLoose wires on E.C.O.--------------------------------------------Secure wire connectionsLoose wire connections on solenoid valve --------------------Secure wire connectionsLoose valve wire on wiring harness ----------------------------Repair wire on edge connector or replace wiring circuit board harnessDefective E.C.O. --------------------------------------------------Replace E.C.O.Defective circuit board--------------------------------------------Replace circuit boardDefective solenoid valve------------------------------------------Replace coils or solenoid valveNo gas to solenoid valve ----------------------------------------Correct gas supplyDirty connector on circuit board --------------------------------Clean edge connector

    WAT ER HEAT ER L OCK OUT - GAS PRESENT BUT NO SPARK

    High tension lead wire loose ------------------------------------Secure wire connection on circuit boardElectrodes loosely attached to main burner ------------------Secure electrodes to main burnerImproper electrode gapping ------------------------------------Re-position spark gap to 1/8 and into path of flameDirty electrodes --------------------------------------------------Clean electrodesWires loose in electrode porcelain------------------------------Replace electrodesCracked porcelain on electrode----------------------------------Replace electrodesDefective circuit board--------------------------------------------Replace circuit board

    WAT ER HEAT ER L OCK OUT - GAS AND SPARK PRESENT

    Gas pressure incorrect ------------------------------------------Set inlet pressure at a minimum 11 W.C. with two or more gasappliances running

    Low voltage--------------------------------------------------------Correct power supply - 10.5 VDC minimumPoor electrical ground--------------------------------------------Secure electrical groundElectrodes out of flame pattern --------------------------------Re-adjust electrodesElectrodes sparking to screw fastening burner to flue tube Adjust electrodes away from screwDirty electrodes --------------------------------------------------Clean electrodes

    Partial obstruction in main burner ------------------------------Clean main burnerPartially obstructed main burner orifice------------------------Clean main burner orifice or replaceImproper air adjustment ----------------------------------------Adjust main burner air shutter approximately 1/4 openFlame spreader on main burner out of adjustment ----------Adjust flame spreader so that it is square to the end burner tube out

    of alignment of the main burnerManifold not aligned with main burner ------------------------Re-align solenoid valve with main burnerPartially opening solenoid valve --------------------------------Replace solenoid valve

    Defective circuit board--------------------------------------------Replace circuit board

    Electronic Ignition Water He ater

    TROUBLE SHOOTING GUID E

    Effe c tive : 5/26/98

    continued

  • 7/28/2019 Atwood Water Heater Service

    20/40

    20

    Electronic Ignition Water Heater (continued) Effe c tive : 5/26/98

    CAUSE SOLUTION

    EXCESSIVE OR INSUFFICIENT WATER TEMPERATURES

    By-pass kit valves not set properly ----------------------------Place valves in proper positionThermostat not seated against tank----------------------------Reseat thermostatDefective thermostat----------------------------------------------Replace thermostat

    ERRATIC BURNER FLAME OR SOOTING

    Low gas pressure ------------------------------------------------Set inlet pressure at a minimum 11 W.C. with two or more gasappliances running

    Poor gas supply --------------------------------------------------Replace gas supplyImproper air adjustment ----------------------------------------Adjust main burner air shutter approximately 1/4 way open. Flame

    should be mainly blue and quiet.Poor main burner alignment ------------------------------------Adjust valve and main burner alignmentMisaligned burner flame spreader ------------------------------Align flame spreader so it is square with end of burner tube.Blocked burner orifice--------------------------------------------Clean orifice. DO NOT enlarge orificeObstructed main burner------------------------------------------Clean main burnerObstructed U tube----------------------------------------------Clean U tubeObstructed exhaust grille ----------------------------------------Remove obstruction

    NO SPARK AND NO GAS

    No voltage --------------------------------------------------------Correct power supply - minimum 10.5 VDCDirty edge connector on circuit board--------------------------Clean edge connectorDefective thermal cut-off ----------------------------------------Replace thermal cut-offDefective ON/OFF switch ----------------------------------------Replace switchDefective circuit board--------------------------------------------Replace circuit boardDefective thermostat----------------------------------------------Replace thermostat

  • 7/28/2019 Atwood Water Heater Service

    21/40

    21

    Guides are only intended for use on Atwood products by service technicians who have

    successfully completed Atwood training. This guide s hould be use d in co njunction w ith

    the a ppropriate Instruction Manual provided with the product and any app lica ble Industry

    S tanda rds . This is not intended to be a c omplete list. P lea se d irect q uestions conc erning

    service of Atwoo d products to 800-825-4328 before proceeding.

    1. CHECK ALL OF THE WIRE CONNECTIONS.

    P oor or corrod ed w ire c onnec tions ca use mo st o f the intermittent problems in wa ter heaters. You

    sho uld g o through a nd pull a ll of the w ires off any s pa de co nnections. Then rec onnec t them a nd

    ensure the co nnections a re tight a nd c orros ion free.

    We w a nt to po int out two co nnections often o verlooked.

    First, check the (green) ground wire of the circuit board. This w ire s crews do w n under

    the circuit board mounting screw. If that screw for the board is loose, you may not have asecure ground.

    Second, check the four wire edge connector going into the circuit board. Remove thecircuit boa rd . Ta ke a penc il eras er and clea n the ma rks o ff the c onne c tion of the c irc uit

    board. Reconnect the four wire edge connector onto the circuit board and then immediately

    remove it. Look at the edge connection of the board. You need to see four good scratches

    in the co nnection. If you do not s ee four scratc hes, then you w ill need to repair the ed ge

    connector or replace the wire harness.

    2. CHECK THE INTEGRITY AND POSITION OF THE SPARK PROBE ASSEMBLY.

    The ga p betw een the spa rking probe a nd the ground probe sho uld b e

    1/8 inc h. The probe s s hould be c lea n a nd free of cra cks , fla king a nd

    corrosion. Position the probes so that they are in the path of the gasflow. Cracks in the ceramic insulator can also be the source of an

    intermittent p rob lem. To c hec k for cra c ks ins ert a fiber wa sh er or any

    other type o f insula tion ma teria l in the 1/8 g a p b etw een the rod s.

    Remove the ga s valve from the circuit a nd turn the unit on. If you s ee

    a spa rk jumping from the ce ra mic to the g round rod or brac ket,

    replace the spark probe.

    3. CHECK THE ALIGNMENT OF THE MAIN BURNER TO THE ORIFICE.

    P os ition the ma in burner tube (A) so that the g a s co ming o ut

    of the orifice (B) is going straight down the middle of the

    burner tube. If the a lignment is off, the ga s w ill bounc e d ow n

    the tube w hich w ill a lter the g a s flow onc e it rea ches thespark. Manually shift the valve (C) with your hands to achieve

    this alignment.

    4. CHECK THE ALIGNMENT OF THE FLAME SPREADER ON THE BURNER TUBE.

    At the end of the burner tube there is a dime-shaped deflector

    disk. This disk sprea ds the fla me o ut for proper hea t d ist ribution.

    Alig n the fla me s prea de r (A) so tha t it is pa rallel to the end of the

    tube and positioned in the center of the end of the tube. If the

    flame spreader is out of position, it could divert the gas away

    from the spark and cause intermittent ignition.

    INTERM ITTENT IGNITION

    Electroni c Igni tion Water Heater

    INFORMATION GUIDE

    Effe c tive : 8/21/00

    continued

    1/8"

    C B A

    A

    1/4 open

  • 7/28/2019 Atwood Water Heater Service

    22/40

    22

    Intermittent Ignition Water Hea ter (continued) Effe c tive : 8/21/00

    5. CHECK THE AIR ADJ USTMENT.

    The burner tube ha s a n a djusta ble air shutter on it a t the end whe re it goe s over the orifice .

    P os ition the a ir shutter so tha t it is 1/4 of the w a y open. We a re looking for a b lue fla me w ith

    small traces of yellow in the flame. If the flame is fairly quiet then it is adjusted correctly.

    6. CHECK THE CLEANLINESS OF THE ORIFICE.

    The orifice is the hex hea d b ra ss fitting tha t is sc rew ed onto the bras s ma nifold of the va lve. You

    will have access to this part once the burner has been removed. Remove the brass orifice andclean with isopropyl alcohol. NEVER enlarge the size of the orifice.

    7. CHECK FOR OBSTRUCTIONS IN THE MAIN BURNER TUBE.

    The c lea nliness of this tub e is very important. S pide r w ebs , so ot a nd o ther debris c a n

    a cc umula te, ca using problems w ith ga s flow do wn the tube. We rec ommend cleaning the burner

    tube w ith a b rush a nd not c ompress ed a ir. Co mpres se d a ir ma y not fully remove the ob struction.

    8. CHECK THE CLEANLINESS OF THE FLUE TUBE.

    The flue tube is the 2-1/2 inc h diame ter tube tha t sta rts a t the bo ttom rig ht co rner of the w a ter

    hea ter (whe re the ma in burner fla me enters) a nd c omes out the top left. This tube c a n bec ome

    bloc ked b y de bris like inse ct ne s ts o r so ot. To c lea n remo ve the me ta l flue bo x in the top left

    co rner of the w a ter heater. To fa cilita te c lea ning unfold a wire ha nger, w ra p a ra g a round the enda nd use this to s wa b out the tube.

    9. CHECK THE VOLTAGE TO THE VALVE.

    Make sure tha t the volta ge to the g a s s olenoid valve is b etw een 10.5 a nd 13.5 volts DC . Volta ge

    drops c a n occ ur a t almost a ny comp onent. Turn on ano ther twe lve volt ap plia nces w hen you

    chec k the volta ge s o tha t you ca n see ho w the c onverter is w orking w ith a load . The volta ge

    itself can be intermittent. With linear converters the 12 VDC varies depending on the 115 VAC.

    If the 115 VAC is high then the 12 VDC will be high, and if the 115 VAC is low then the 12 VDC

    w ill be low. If the po we r to the w a ter heate r is co nnecte d to the unfiltered side o f the c onverter,

    move it to the filtered side.

    10. CHECK THE GAS PRESSURE OF THE RV.Make sure the gas pressure of the RV is checked with preferably the furnace and the range on

    to s imula te a loa d. The pres sure should b e 11 inch w a ter column under loa d. B es ide s g a s

    pres sure being a t the proper level there a re othe r stra nge things that ca n ha ppen inside ga s lines

    that ca use intermittent prob lems . We ha ve se en oil build up in a ga s line tha t mea nt there w a s

    good pressure to one appliance but not the correct pressure to another appliance. Moisture

    could also build up in the gas line that would freeze and partially block the line. Intermittent

    pres sure from the reg ula tor of the bo ttles is still a nother area that sho uld be investiga ted.

    11. INTERMITTENT CIRCUIT BOARD.

    If you have gone through all of the above checks and the intermittent problem is still occurring,

    only then c heck the c ircuit bo a rd. Ensure the c ircuit boa rd is c lea n a nd reas ona bly moisture free

    before you change it.

    There a re tw o ma jor points tha t s hould have sto od out to you from this list.

    First, the majority of intermittent ignition problems on Atwood electronic ignition water heaters

    can be corrected by cleaning certain components or making simple adjustments.

    S ec ond , ignition p rob lems ca n be found in other compo nents than the c ircuit boa rd. The c ircuit

    bo a rd is not the end a ll s olution to ignition problems . This minds et developed a num be r of yea rs

    a g o w ith the introd uction of the first c irc uit bo a rds tha t w ere not very relia ble. Weve lea rned a lot

    since t hen. Tec hnolog y ha s p rog res s ed ma king to da ys circ uit bo a rds very relia ble. The c irc uit

    boa rd c an o nly do wha t the other compo nents of the wa ter heater allow it to d o.

  • 7/28/2019 Atwood Water Heater Service

    23/40

    23

    * * POTTED CHANNEL CIRCUIT BOARDSAtwo od **potted circuit boa rds ca n be te sted using a

    multi-meter. This tes t mus t be p erformed w ith the

    circuit board removed, and the meter set to the ohmssc a le. This w ill chec k the co ntinuity of a ll tra cks on

    the harness c onnection of the bo ard.

    The following steps should be used to test each track.

    A. Cross leads of meter to ensure it is registeringcontinuity.

    B. TO TEST POWER TRACK:Place negative lead of the multi-meter to ground (greenwire) track of edge connection and positive lead of themulti-meter to top power (brown wire) track of edgeconnection. If no continuity, board is defective. *Atwooddoes not warranty this installation related failure.

    C. TO TEST LAMP TRACK:Place negative lead of the multi-meter to ground (greenwire) track of edge connection and positive lead of themulti-meter to lamp (blue wire) track of edgeconnection. If no continuity, this indicates blown lamptrack. Circuit board will still fire unit but lamp light willnot come on. This is caused by a short in the blue wirebetween the unit and the switch. Wiring must becorrected before the board is replaced. *Atwood doesnot warranty this installation related failure.

    D. TO TEST VALVE TRACK:Place negative lead of the multi-meter to ground (greenwire) track of edge connection and positive lead of the

    multi-meter to valve (red wire) track of edge connection.If no continuity, this indicates a blown valve track. If the valve wire is shorting under the flue box Atwood will warranty the board.

    If the E.C.O. terminals are contacting the drawn pan Atwood will warranty the board only if the innertank of the water heater was installed flush on thefloor of the coach.

    If the inner tank of the water heater does not restflush against the floor of the coach *Atwood doesnot warranty this installation related failure.

    * Installation related failures on circuit boards are theresponsibility of the coach manufacturer.

    ** Non potted circuit boards can be checked by turning theboard over and visually inspecting each track for a burnmark or break in the track itself. A burn mark or brokentrack indicates the board is blown. Depending on whichtrack is blown determines whether it is covered underAtwoods warranty as stated in section B, C and D.

    THERMAL CUT-OFF DEVICECurrent Atwood direct ignition water heaters are equipped

    with a thermal cut-off device. This device is located on theincoming power wire and is connected to the thermostat. Thethermal cut-off is designed to permanently break circuit andshut down the water heater before excessive heat can causedamage due to obstructions in the main burner tube or fluetube caused by spiders or mud wasps. These obstructionscan cause the main burner flame to burn outside the mainburner tube. When the flame or the heat from the flamecontacts the thermal cut-off, the circuit will open.

    If there is no heat damage to the thermal cut-off, and if it isdetermined defective, Atwood will cover the replacement ofthis device under warranty. We will allow .25 hour at your

    Atwood approved warranty rate. If there is heat damage thedevice performed its safety feature and no warranty labor willbe allowed. Any obstructions should be removed, alignmentchecked and gas pressure taken before a new thermal cut-offis installed.

    Note: When replacing a thermal cut-off, also examine the grillin the access door while the door is in the closedposition. The wide aluminum band of the grill shouldbe at the bottom. If it is at the top, this condition maytrap exhaust heat and possibly also cause thermal cut-off to trip. To correct, remove the grill from the doorand snap back in place with the wide aluminum band at

    the bottom.

    THERMOSTATThe thermostat on this water heater is pre-set at 140 F. Thewater heater will cycle off when the water temperaturereaches 140 F. and will generally take 20-25 minutes toreach this temperature. It will cycle back on when the watertemperature cools down to approximately 115 F. In the latterpart of the heating cycle though, it is very common for thepressure-temperature relief valve to weep. Refer to the pagecovering weeping relief valves to remedy this situation.

    If a customer is dissatisfied with the temperature of the

    water, first check the water temperature with a cookingthermometer and verifying that the initial cycle is within thetime noted above. If not, an adjustable thermostat may bepurchased allowing the water temperatures to be adjustedfrom 110 - 150 F. It fits in place of the original thermostat.

  • 7/28/2019 Atwood Water Heater Service

    24/40

    24

    Water Heater Wiring Schematics

    Gas SolenoidValves

    ECOSwitch

    Non-IgnitionLight

    Fixed TemperatureControl Therm ostat

    RemoteSwitch

    12 volt DC

    Spark & Sense

    Thermal Cut-Off

    RED

    RED

    BLUE

    BROWN

    GREEN

    GREEN

    BROWN BROWN

    GREEN

    ( 6 ) ( 4 )

    ( 3 ) ( 2 )

    GREEN

    BLUE

    (6)(4)(3)(2)

    BATTERY

    REMOTE

    SWITCH

    BROWN

    Do t t e d l i n e s a r e w i r e d b y c u s t ome r

    When servicing controls, label all wires prior to disconnection.

    Wiring errors can cause personal injury or property damage.

    Verify proper op eration a fter servicing.

    CAUTION

    Wiring Schematic G 6A-7E, G H6-7E,G C6A-7E, G CH6-7E, G C6AA-7E,

    G 6A-8E, G H6-8E, G C6AA-8E,

    G CH6AA-8E, G CH6A-9E

    Va lve

    Re d

    Re d

    Re d

    White

    Circuit

    Board

    Brown

    Brown

    Blue

    Green

    Re d

    Sparker

    Battery

    123

    456

    Wire Connection

    Wiring Schematic G 6A-3E,G6A-4E, G H6-3E, G H6-4E,

    GC H6-4E, G 6A-6E, GC H6-6E,

    GH6-6E Wat er Heate rs

    (Front Mount ECO a nd

    Thermos tat Models).

    EC O TSTAT

    Wiring SchematicG 6A-2E, G 6A-3E, G H6-4E,

    G H6-3E Wat er Heate rs

    (Rea r Mount ECO a nd

    Thermos ta t Mode ls).

    Va lveWhite

    Green

    Re d

    Brown Blue

    Circuit

    Board Orange

    Sparker

    WhiteGround

    Battery

    WhiteNon-ignition

    Light

    J unction Bo x on Ba ck of Unit

    Wire Connection

    REM OTE

    SWITCH

  • 7/28/2019 Atwood Water Heater Service

    25/40

    25

    GENERAL INFORMATION

    QUESTIONS

    The following questions should be answered during this portion of the manual:

    What causes the pressure-temperature relief valve to weep when unit is in heating cycle?

    How can weeping pressure-temperature relief valves be reduced or eliminated?

    What are the proper draining procedures to help reduce lime deposits and extend tank life?

    Will a ta nk split for a ny other reas on b es ide s freezing?

    What functions do the retaining rings se rve when repla cing a n inner tank?

    What a re the most c ommon w a ys to w interize a tank?

  • 7/28/2019 Atwood Water Heater Service

    26/40

    26

    PRESSURE-TEMPERATURE RELIEF VALVEWeeping or dripping of a pressure-temperature relief valve while the water heater is running DOES NOT mean it isdefective. This is normal expansion of water as it is heated in the closed water system of a recreation vehicle. TheAtwood water heater tank is designed with an internal air gap at the top of the tank to reduce the possibility of weepingand dripping. In time, the expanding water will absorb this air. To replace the air follow these steps:

    Step 1: Turn off water heater

    Step 2: Turn off incoming water supply

    Step 3: Open the closest hot water faucet in the coach

    Step 4: Pull handle of pressure-temperature relief valve straight out and allow water to flow until it stops.

    Step 5: Allow pressure-temperature relief valve to snap shut, turn on water supply and close faucet.

    WATER HEATER TANK CORROSIONPinhole leaks from galvanic corrosion may cause the water heater tank to fail.

    Microscopic particles of metals (like iron and copper) suspended in water, set up a reaction inside the water heater thatis not unlike the principle on which an automotive battery operates. The aluminum tank is the anode and the metals inthe water serve as the cathode. Consequently, the aluminum gradually sacrifices itself and aluminum particles are carriedaway with the water flow.

    A white scaly material (aluminum oxide) often is formed around the points where the heaviest action is taking place andheat accelerates the process. Severity of the problem varies considerably in different locales depending on the metal andmineral content of the water. White deposits inside the water heater tank are usually from water impurities that havesettled out.

    Periodic flushing of the water heater tank under pressure is recommended to slow down this process. For flushing

    instructions see your owners manual or contact Atwood for a copy of our recommended procedure.

    ATWOOD CLAD TANKThe Atwood water heater tank is constructed of a core of high strength aluminum. The interior of the tank consists of a15% thickness of type 7072 aluminum (pure aluminum and zinc) that is fused to the core during the rolling process.This material protects the tank from the affects of heavy metals and salts found in waters throughout the country. It isanodic to these heavy metals and acts much like an anode in a steel glass lined tank except it will last much longer.There is also no need to replace an anode on a yearly basis.

    Flushing the tank on a regular basis has been found to be helpful in insuring the best performance of your water haterand adding to the useful life of the tank. For flushing instructions see your owners manual or contact Atwood for a copyof our recommended procedures.

    Air Expansion Pocket

    Relief Valve

    125/150 psi210

    Hot Water Outlet

    Cold Water Inlet1/2" N.P.T.Drain Plug

  • 7/28/2019 Atwood Water Heater Service

    27/40

    27

    FLUSHING YOUR WATER HEATER TO REMOVETHE ROTTEN EGG ODOR

    1. Turn off your main wa ter supply. Drain you wa ter

    hea ter tank. Reinstall drain plug. Remove thepress ure-tempe rature relief va lve. With a funnel

    use 4 pa rts w hite vinega r to two pa rts w a ter. (In a

    6 ga llon ta nk that w ould b e 4 ga llons vinega r to 2

    ga llons wa ter).

    2. C ycle the wa ter heate r, letting it run unde r norma l

    operation 4-5 times. At no time do you remove the

    vinega r from the ta nk Once this has b een

    co mpleted , remove the d rain plug a nd d rain the

    water heater.

    3. After thoroughly draining the tank, to remove the

    se diment, flush the w ate r heater.

    If you elect to use air press ure, it may be a ppliedeither through the inlet or outlet on the rear of the

    tank or applied through the pressure-temperature

    relief valve. Remove the pressure-temperature

    relief valve and insert your air pressure through

    the p res sure-tempera ture relief va lve c oupling . In

    either cas e, w ith the drain valve o pen, the a ir

    pressure will force the remaining water out of the

    unit.

    If air pressure is unavailable, your unit can be

    flushed with fres h wa ter. Fresh wa ter should b e

    pumped into the ta nk either with the o nboa rd

    pump or external wa ter pres sure. External

    press ure ma y b e hos ed into the unit either

    through the inlet or outlet found on the rear of the

    ta nk or the pres sure-tempera ture relief va lve

    coupling loc ate d on the front o f the unit.

    Continue this flushing process for approximately

    five minutes allowing ample time for the fresh

    wa ter to ag itate the stag nant wa ter on the

    bottom of the tank and forcing the deposits

    through the d rain op ening.

    4. Upon completion of the steps above, replace the

    drain plug and the pressure-temperature relief

    valve.

    5. Refill tank with fres h wa ter that c onta ins no

    sulphur.

    The Atwo od wa ter heater is d esigned for use in a

    Rec rea tion Vehicle. If you use your vehicle freq uently

    or for long period s o f time, flushing the w ate r heater

    se veral times a yea r will prolong the life of the storag e

    tank.

    WINTERIZING INSTRUCTIONS

    1. Turn off your main water supply, that is, your pump oryour water hook up source.

    2. Drain your water heater inner tank. Upon doing so, youwill note that, due to the location of the drain plug,approximately two quarts of water will remain in thebottom of the tank. This water contains most of theharmful corrosive particles. If while draining the unit, younote that it is flowing sporadically or trickling, instead offlowing steadily, we recommend one of two things. Youshould first open your relief valve to allow air into the

    tank and secondly, take a small gauge wire or coathanger device and prod through the drain opening toeliminate any obstructions.

    3. After thoroughly draining the tank, you should then flushit with air pressure or fresh water. If you elect to use airpressure, it may be applied either through the inlet oroutlet on the rear of the tank. It may also be appliedthrough the relief valve part. In this case, it will benecessary to first remove the relief valve support flange.In either case, with the drain valve open, the air pressurewill force the remaining water, along with the corrosiveparticles, out of the unit. However, if air pressure isunavailable, your unit can be flushed with fresh water.

    Fresh water should be pumped into the tank either withthe assistance of the on-board pump or with theassistance of external water either through the inlet oroutlet found on the rear or the relief valve couplinglocated on the front of the unit. Continue this flushingprocess for approximately five minutes allowing ampletime for the fresh water to agitate the stagnant water onthe bottom of the tank and thus forcing the depositsthrough the drain opening.

    4. Upon completion of the steps above, replace the drainplug and the pressure-temperature relief valve.

    5. After this procedure, there will be approximately two

    quarts of water left at the bottom of the inner tank.Should this water freeze it will not cause any splitting ofthe tank.

  • 7/28/2019 Atwood Water Heater Service

    28/40

    28

    Terminology Definition

    AGA American Gas Association

    Access Door hinged cover on outside of waterheater

    By Pass Kit a combination of hoses and valvesthat can aid in the winterization of

    the water heaterCGA Canadian Gas Association

    Calibration the condition determining whetherthe thermostat is registeringtemperatures properly

    Cam-Loc Fastener a door securing device

    Circuit Board an electronic panel that controls thespark, solenoid valve and sensesthe main burner flame

    Drawn Pan metal pan attached to the waterheater tank and fastened to coach

    sidewall to isolate combustion tooutside of coach

    DSI direct spark ignition a.k.a.electronic ignition

    E.C.O. (energy cut off) high temperature re-set shut offdevice

    Electrolysis electro chemical corrosive processthat can cause pinholes in tanks

    Fenwal Tester a diagnostic circuit board analyzer

    Flame Spreader a round deflective piece found atthe combustion end of main burner.

    Flue Box a chamber that separates air intakeand exhaust

    Flue Tube combustion and water heatingsurface area on inside of tank

    Flying Lead flame sensing wire that issometimes found hard wired tocircuit board

    Front of Water Hea ter access door side of water heater

    Gas Solenoid Valve a 12 volt DC device that turns on oroff the flow of gas

    Immersion Element an AC electrical heating coil that isimmersed directly into water

    Inverted Flare type of connection using doubleflare fitting and tube nut

    Inner Tank patented, designed vessel for

    heating water

    Jade Knob Clip a horse shoe retainer clip on mainshaft of J ade Gas thermostat thatallows for proper moving ofON/OFF knob and shaft

    Terminology Definition

    Main Burner a gas and air mixing tube

    Main Burner Air Shutter the slotted sleeve on tube thatallows for gas and air adjustment

    Main Burner Orifice a precision drilled fitting thatregulates the BTU's of

    combustion

    N.P.T. (Nat'l Pipe Thread) a plumbing measurement standard

    Pilot Assembly A gas tube, orifice & thermocouple

    Pilot Orifice a precision drilled thimble shapedcomponent that meters gas flowto pilot

    Pilot Relight Ignition Module 12 volt electronic panel thatprovides spark ignition and flamesense to maintain pilot flame

    Pressure-Temperature a pressure and temperature safety

    Relief Valve device used on water heatingvessels.

    Ring and Gasket retaining fiber & metal rings thatsecure combustion pan to tank

    Sight Glass burner flame viewing port onaccess door

    Spark Probe Assembly a spark electrode & flame sensing

    Thermal Cut-Off heat sensing diode that cutspower to circuit board if a flamebacks out of the burner tube orflue tube normally caused by an

    obstruction in these areas

    Thermostat (gas) a temperature sensitive device forturning on and off the flow of gas(T-stat)

    Thermostat (120 volt AC) a surface mount temperaturesensitive device that turns on/offheating element

    Thermostat (12 Volt DC) a surface mount temperaturesensitive device that turns on/offthe voltage to the circuit board

    Thermocouple a device, when heated, generatesmillivolts of electricity

    UL Underwriters Laboratories

    "U" Tube also referred to as a flue tube onsome water heater models

    Winterization process of preparing a waterheater for cold winter storage

    WATER HEATER TERMINOLOGY

  • 7/28/2019 Atwood Water Heater Service

    29/40

    29

    ATWOOD WATER HEATERLIMITED WARRANTY

    Atwoo d Mobile P roducts w arrants to the o riginal owner and s ubject

    to the below mentioned conditions, that this product will be free ofdefects in ma terial or workmanship for a pe riod of two years fromthe original da te of purcha se. Atwo od s liab ility hereunder is limited

    to the replac ement of the product, repair of the product, orreplac ement of the product with a reconditioned product at thedisc retion of the ma nufac turer. This wa rranty is void if the prod uct

    has been da maged by a ccident , unreaso nable use , neglect ,

    tampering or other ca uses not a rising from d efects in ma terialwo rkma nship. This wa rran ty extends to the origina l ow ner of the

    product only and is subject to the following conditions:

    1. For a period o f two yea rs from the da te of purcha se, Atwood w illreplace the complete water heater if the inner tank leaks due tocorrosion. This wa rranty includes reasona ble labor cha rges

    required to replace the complete water heater.2. For two years from the da te of purchase, Atwood will repair or

    repla ce a ny pa rt defec tive in material or workmans hip. This

    wa rranty includes reasona ble lab or charges , required to removeand replac e the pa rt. Service c alls to customers loca tion a re notcons idered pa rt of these c harges a nd a re, therefore, the

    responsibility of the owner.3. This wa rran ty does no t cover the follow ing items c lass ified a s

    normal maintenanc e:

    a . adjustment o f g as pressureb. cleaning or replac ement of burner orifice

    c . c leaning or adjustment of burner tubed. cleaning or ad justment of f luee. cleaning or a djustment of pilot a nd thermoco uplef. ad justment of press ure-temperature relief valve

    4. In the event of a warranty claim, the owner must contact, inadvance, either a certified Atwood Service Center or theAtwood Service Department. Warranty claim service must be

    performed at a certified Atwood Service Center (a list will beprovided at no charge) or as approved by the Consumer ServiceDepartment, Atwood Mobile Products, 4750 Hiawatha Drive,Rockford, IL 61103-1298 USA. Phone: (815-877-5700).5. Return parts (or wa ter heater) must be s hipped to Atwo od

    Prepaid. Credit for shipping costs will be included with the

    wa rranty c laim. The defec tive pa rts (or wa ter heater) bec ome theproperty of Atwoo d Mobile P roducts a nd must b e returned to theCons umer Service Department, Atwood Mobile P roducts, 4750

    Hia wa tha Drive, Ro ckford, IL 61103-1298 USA.

    6. This wa rranty ap plies on ly if the unit is ins ta lled a cc ording to theinstallation instructions provided and complies with local and statecodes.

    7. The wa rran ty period o n replac ement pa rts (or wa ter heater) is theunused portion of the original warranty period.

    8. Da ma ge o r failure resulting from misus e (including failure to seek

    proper repair service), misapplication, alterations, water damage,or freezing are the ow ners respo nsibility.

    9. Atwoo d does not as sume responsibility for any loss of use of

    vehicle, loss of time, inconvenience, expense for gasoline,telephone, travel, lodg ing, loss or da mag e to p ersonal propertyor revenues. S ome s tates do not a llow the exclusion o r limitation

    of incidental or conseq uential da mag es, s o the a bove limitationsor exclusions may not a pply to you.

    10. Any implied wa rranties a re limited to tw o (2) years. So me s tates

    do not allow limitations on how long an implied warranty lasts, sothe a bove limitation ma y not a pply to you. This w arranty g ives

    you specific legal rights and you may also have other rights whichvary from sta te to s tate.

    11. Replac ement parts (components or ta nks) purcha sed outside ofthe original wa ter heater wa rra nty ca rry a 90 da y wa rra nty. This

    includes the part at no charge and reasonable labor charges torepla ce it.

    This Atwo od hea ter is des igned for use in recreational vehicles for the

    purpose of hea ting wa ter as stated in the data plate a ttached to thewa ter heater. Any other use, unless authorized in writing b y the AtwoodEngineering Depa rtment, voids this wa rranty.

    Warranty ProceduresAtwood water heater, furnace, range, hardware or detectorwarranties can be submitted in one of two ways.

    If you are already set up with an owner care program with anOEM, you should submit the faulty part and claim throughtheir system.

    To submit a claim directly through Atwood the followinginformation is required:

    1. Owners Name and Address.

    2. Date of Purchase - obtain from copy of original bill of sale.

    3. Model and Serial Number - The model and serial number,which is located on every water heater, furnace and rangeis required on all Atwood appliance claims.

    4. Manufacturer, Model, Year and VIN # of RV.

    5. Work Performed - Describe in detail findings of existingproblem and corrective measure taken.

    6. Return Parts - A MUST RETURN parts list is attached.Failure to return parts listed will result in denial of your

    warranty claim.7. Return Good Number - a Return Goods Number (RGN)

    must accompany all returned parts. This number may beobtained by calling the Atwood Mobile Products ServiceDepartment at 1-800-825-4328. The RGN must be clearlymarked on the outside of each carton. Failure to do so willresult in your shipment being refused at our receivingdepartment.

    8. Return Freight - Atwood does not accept C.O.D.shipments. Freight to return parts to Atwood should beindicated on your claim or repair order and you will bereimbursed.

    9. Travel Time - Because our warranty is based on thecustomers ability to present the unit for service, and in anattempt to maintain our low cost products, reimbursementfor mileage, service calls and travel time WILL NOT BEALLOWED.

    10. Payment for Warranty Service - All parts are replaced atno charge, freight prepaid upon our inspection. Labor, onnet 30 accounts is paid by credit memo within 30 days ofreceipt of parts.

    11. Flat Rate Schedule - A reasonable flat rate schedule forwarranty repairs has been set for each Atwood productand/or parts. Should unusual circumstances take you

    beyond the standard time allowance, you must have priorapproval by contacting the Atwood Mobile ProductsService Department at 1-800-825-4328, and press option5 after the recording.

  • 7/28/2019 Atwood Water Heater Service

    30/40

    30

    Return Goods PolicyEffective August 7, 1995, all Atwood defective returns will no longerbe repaired at the warehouses and returned to customers. Defectivereturns will be shipped back to the respective manufacturing facilityfor problem cause analysis within 30 days of sales. Full credit will beissued if the cause analysis determines Atwood is responsible. If thecause analysis determines the customer is responsible, partial or nocredit will be issued.

    Warranty Returns - the warranty policy, must return policy andapproved labor rates provide the framework for warranty returns byproduct line.

    Non-Defective Returns - A restocking fee of 20% will be chargedfor handling of overstock returns or standard stock items orderedincorrectly by the customer providing the product is received inresalable condition. Product that has been specifically designed ata customers request is non-returnable. Obsolete or out datedproduct will not be accepted for credit.

    Shipping Dam age - Once the product has been accepted at its finaldestination it is the customers responsibility to file a damage claimwith the carrier.

    Follow Warranty Procedures for Atwood returns.

    Return PartsWhen returning parts, there are three divisions responsible forspecific product and their claims. Prior to returning parts, a ReturnGoods Number (RGN) must be obtained by calling the AtwoodMobile Product Service Department at 800-825-4328.

    Shipping - Reasonable shipping charges are reimbursed ondefective and warranty parts if the analysis determines Atwood isresponsible for the disposition. All products not shipped via Atwoodtrucks should be shipped prepaid via UPS ground unless negotiatedat the time the RGN is given. No collect shipments will be accepted.

    Packaging -The RGN must be identified on each container & allpacking information. Product returned must be properly packagedto prevent shipping damage. Full credit will not be issued onproduct sent back on an open skid or improperly packaged.Additional product boxes are available upon request.

    Submit claims to the correct division. Failure to do so makes claimprocessing a more difficult and lengthy process delaying payment of yourclaims. Together we can maintain a speedy and efficient warranty program.

    WATER HEATERS//HARDWARE (jacks, couplers, 5th wheel & braking systems)

    Atwood Mobile Products4750 Hiawatha DriveRockford, IL 60013

    Must Return Parts ListUnder Atwoods Warranty Administration Program we require,with the return of warranty claims, the specific parts noted below.Failure to accompany your claims with these parts will result inthe non-shipment of a replacement part, or the non-processingof the appropriate credit until such time as the part is received byAtwood.

    Before returning the part, a RGN (Re turn Goods Number) must beobtained. This number can be acquired for all products exceptseating, by calling the Atwood Mobile Products ServiceDepartment at 1-800-825-4328. To obtain RGNs for seatingcomponents, please call 1-219-522-7891. Without this RGNappearing on the outside of the shipping carton, the shipmentwill be refused at our receiving department.

    FURNACE

    All parts

    HARDWARECouplersJ acksActuatorsMaster cylindersShock absorbersFoundation brakesPower jacksPower jack motorsAll 5th Wheel items

    RANGE & OVENSRegulatorsOven thermostatsSafety pilot valvesBurner valvesManifoldsTop pilot valves12v ignition moduleBurners w/ignitionelectrodeComplete ranges (BY

    APPROVAL ONLY)

    SEATING COMPONENTS

    All parts

    WATER HEATERComplete water heatersInner tanksGas thermostat valvesCircuit boardsGas solenoid valvesElectric thermostatsHeating elementsPilot assemblies

    Spark probe assembliesE.C.O. & T-stat kitsThermal cut-offsPressure-TemperatureRelief

    Valves

    FOR EFFICIENT PROCESSING OF CLAIM1. Call for a RGN number.2. Fill Warranty Service Report form out completely.3. Using tape or a tag mark the returning part with the

    RGN #.4. Package part including the Warranty Service Report in

    the box.5. On the outside of the package clearly mark the RGN

    number.

    6. Return part to the correct Division of Atwood MobileProducts.

    FURNACE/LP DETECTORS

    Atwood Mobile ProductsSalt Lake City Operations1874 South Pioneer RoadSalt Lake City, UT 84104

    CO DETECTOR

    KIDDE Safety (1-800-880-6788)1394 South Third StreetMebane, NC 27302

    RANGE/COOK TOPS/DROP- INS/SOL-A-VENTSAtwood Mobile ProductsWedgewood Operations6320 Kelly Willis RoadGreenbrier, TN 37073

  • 7/28/2019 Atwood Water Heater Service

    31/40

    31

    J une 17, 2003

    Flat RateSchedule

    Water Heaters

    TIME ALLOWANCE SCHEDULE in hours

    Replacement of: Standard Pilot Electronic IgnitionModel Model

    Access Door........................................................................................................ .30 .......................................................................................... .30 ......................................................

    Circuit Board .................................................................................................... N/A .......................................................................................... .50 ......................................................

    Co mplete Wa ter Hea ter ........................................................ 1.50 ...................................................................................... 1.75 * ..................................................

    Dra in Va lve or P lug ................................................................................ .30 .......................................................................................... .30 * ..................................................

    Elec tric On-Off S w itch..................................................................

    .50..........................................................................................

    .50 *..................................................

    Heating Element .................................................................................... 1.00 ...................................................................................... 1.00 * ..................................................

    Inne r Ta nk ............................................................................................................ 2.00 ...................................................................................... 2.30 ......................................................

    Main Burner.......................................................................................................... .50 .......................................................................................... .50 ....................................................

    On-Off Light Wa ll Sw itc h ...................................................... N/A .......................................................................................... .75 ......................................................

    Pilot Assembly ............................................................................................ .50 ........................................................................................ N/A ......................................................

    P ilot Ignitor Mod ule ............................................................................ .50 ........................................................................................ N/A ......................................................

    P ress ure-Temp. Relief Va lve ............................................ .50 .......................................................................................... .50 * ..................................................

    Relay .......................................................................................................................................................................................................................................... .50 * ..................................................

    S oleno id Va lve .............................................................................................. N/A .......................................................................................... .50 ......................................................

    Spark &Probe Assembly ...................................................... N/A .......................................................................................... .50 ......................................................

    Therma l Cut Off ........................................................................................ N/A .......................................................................................... .30 ......................................................

    Thermos ta t &E.C.O. ...................................................................... N/A .......................................................................................... .50 * ..................................................

    Thermo sta t-electric .............................................................................. .50 .......................................................................................... .50 ......................................................

    Thermos ta t-ga s ...................................................................................... 1.00 ........................................................................................ N/A ......................................................

    * ind ica tes time a llow ed for Elec tric/Marine units

    Note: All fla t rates include diag nos tic time a nd w hen a pplica ble,gas leak test.

  • 7/28/2019 Atwood Water Heater Service

    32/40

    32

    13

    8

    76

    15

    5 3

    9

    11

    10

    16

    17

    18

    19

    10

    20

    10

    12

    11

    4

    6 &10 gal.