7
SACRAMENTO MUNICIPAL UTILITY DISTRICT BR 140233.DM Attachment 1 Panel Coating Specifications and Cleaning Instructions

Attachment 1 Panel Coating Specifications and Cleaning … Dry Film Thickness (nominal) ASTM D1400 0.20 – 0.30 mil primer 0.20 mil primer ... proven fabricators and installers in

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Attachment 1 Panel Coating Specifications and Cleaning … Dry Film Thickness (nominal) ASTM D1400 0.20 – 0.30 mil primer 0.20 mil primer ... proven fabricators and installers in

SACRAMENTO MUNICIPAL UTILITY DISTRICT BR 140233.DM

Attachment 1

Panel Coating Specifications and Cleaning

Instructions

Page 2: Attachment 1 Panel Coating Specifications and Cleaning … Dry Film Thickness (nominal) ASTM D1400 0.20 – 0.30 mil primer 0.20 mil primer ... proven fabricators and installers in

PMS 3405 Black 160 6079 REMAY 77496-A (66022-G) (68029-G, 72722-G, 73420)trim: 8.500" x 11.000" bleed: .125" Digital/IAM Asset No. 77496-A

252 50 100 252 50 100

QC�______ ______ Client�_____ _____

Date ____/____/____ Proof No.��______

SYSTEM OVERVIEW

COMMERCIAL USES

DURABILITY

PRODUCT DESCRIPTION

DURANAR fluoropolymer coil coatings are designed to provide outstanding aestheticsand durability in a wide range ofarchitectural uses under normalenvironmental conditions. Morethan 35 years of field use haveproven them to be the standardof excellence in architectural fluoropolymer finishes. DURA-NAR coil coatings combine PPG proprietary resin and pigment technologies with 70%of the resin system being fluo-ropolymer base resins. The coat-ings are highly resistant to chalk-ing, fading, chipping, and peelingwhen properly applied by anapproved applicator. DURANARcoil coatings meet or exceedAAMA 620/621 and the perfor-mance requirements (section 7)of American ArchitecturalManufacturers Association(AAMA) 2605-05 VoluntarySpecification, PerformanceRequirements and TestProcedures for SuperiorPerforming Organic Coatings onAluminum Extrusions andPanels. They are approved foruse on properly cleaned andtreated aluminum and coatedsteel substrates such as G90 hotdip galvanized, Galfan®,Galvalume®, and Zincalume®*.They are not intended for use onhot or cold rolled steel substratesfor exterior exposure applica-tions.

DURANAR LG, a low luster,matte finish for DURANAR coilcoating formulations, is alsoavailable for use where non-glareis required or desired, such as forairport, government, and military applications. DURANAR LGprovides a unique appearancethat is functional and aestheticallyappealing. Its low-luster reflectanceprovides a smoother appearanceto walls or roof panels, and it isavailable in any color in whichDURANAR coil coatings areoffered.

P R O D U C T D ATA

DURANAR coatings are two-coat systems

consisting of a corrosion inhibitive primer

and a fluoropolymer topcoat. They are

available in a wide range of consistent,

stable colors and are extremely inert,

providing long-term durability as well as

resistance to chemical attack and surface

damage caused by acid rain, salt spray, and

humidity encountered under normal envi-

ronmental conditions. DURANAR coil

coatings require minimal maintenance and

minor scratches can be easily repaired in

the field.

DURANAR coil coatings are formulated

to provide excellent performance against

weathering in all environments. (Where

added protection against industrial or

seacoast influences is required, DURANAR

PLUS, DURANAR XL PLUS, or DURANAR

XL are recommended.) The DURANAR

two-coat system is an excellent choice for

architectural applications such as storefronts,

building panels, curtainwalls, and roof

panels.

DURANAR coil coatings are chemically

inert, providing excellent resistance to color

and gloss fade as well as environmental stress

including acid rain and ultraviolet attack. The

coatings require very little maintenance, and

most surface contaminants may be removed

by conventional detergents or cleaning solvents.

(Harsh chemicals or solvents must not be

used on DURANAR coated surfaces.) All

pigments are tested for a minimum of ten

years in south Florida prior to approval for

use in any DURANAR coil coating system.

Additionally, DURANAR coil coatings are

tested at exposure sites throughout the world

in all types of climatic and industrial condi-

tions to ensure the coatings’ performance

and durability.

DURANAR ®

COATINGS

DURANAR and the PPG logo are registered trademarks of PPG Industries, Inc.* Galfan is a registered trademark of ILZRO

Galvalume is a registered trademark of BIEC International, Inc. Zincalume is a registered trademark of BlueScope Steel Limited. Steelscape, Inc. holds exclusive rightsto the Zincalume trademark within the U.S.

BR 140233.DM - Attachment 1

2

Page 3: Attachment 1 Panel Coating Specifications and Cleaning … Dry Film Thickness (nominal) ASTM D1400 0.20 – 0.30 mil primer 0.20 mil primer ... proven fabricators and installers in

PMS 3405 Black 160 6079 REMAY 77496-A (77261-A )(66022-G/68029-G)trim: 8.500" x 11.000" bleed: .125" Digital/IAM Asset No. 77496-A

252 50 100 252 50 100

QC�______ ______ Client�_____ _____

Date ____/____/____ Proof No.��______

P R O D U C T D ATA

Aluminum Substrate Coated Steel1 SubstrateDry Film Thickness (nominal)

ASTM D1400 0.20 – 0.30 mil primer 0.20 mil primer0.70 – 0.80 mil topcoat 0.75 mil topcoat

GlossASTM D523Standard @ 60° 25 - 35 25 - 35DURANAR LG @ 85° <10 <10

Pencil HardnessASTM D3363 F-2H F-2H

Flexibility2

T-bend, ASTM D4145 0-2 T-bend; No pick-off 2 T-bend; No pick-offAdhesion

ASTM D3359 No adhesion loss No adhesion lossReverse impact 1/16” crosshatch

Reverse ImpactASTM D27941.5 x metal thickness (aluminum) No cracking or adhesion loss No cracking or adhesion loss3.0 x metal thickness (coated steel) No cracking or adhesion loss No cracking or adhesion loss

Acid ResistanceASTM D130810% muriatic acid — 24 hrs. No effect No effect20% sulfuric acid — 18 hrs. No effect No effect

Acid Rain TestKesternich SO2, DIN 50018 15 cycles min. 15 cycles min.

No objectionable color change No objectionable color change Alkali Resistance

ASTM D1308 No effect No effect10%, 25% NaOH, 1 hr.

Salt Spray ResistanceASTM B117 Passes 4000 hrs. Passes 1000 hrs.5% salt fog @ 95°F Less than 1/16” avg. Less than 1/8” avg.

creepage from scribe; creepage from scribe;None or few #8 blisters None or few #8 blisters

Humidity ResistanceASTM D714, Passes 4000 hrs. Passes 1500 hrs.ASTM D2247 No #8 blisters No #8 blisters100% relative humidity @ 95°F

Exterior Exposure10 yrs. @ 45°, south FloridaASTM D2244 Max. 5 fade Max. 5 fadeASTM D4214 Max. 8 chalk Max. 8 chalk

DURANAR SPECIFICATIONS

DURANAR WARRANTY INFORMATION

PPG offers a comprehensive warranty on DURANAR coil coatings. For complete warranty information and a copy of the DURANAR coil coatings warranty, please call PPG at 1-800-258-6398.

PPG Industries, Inc.151 Colfax St.Springdale, PA 15144(800) 258-6398Fax: (724) 274-2600

www.ppgideascapes.comE-mail: [email protected]

9/09Printed in U.S.A.PPG-22

DURANAR ®

COATINGS

1 Coated Steel includes the following types of steel: G90 hot dip galvanized, Galfan, Galvalume, and Zincalume.2 Fracturing or rupturing of substrate will rupture coatings. Heavy gauge and clad steel substrates impose limitations on formability.

DURANAR coatings are generally flexible beyond the point of substrate rupture.

BR 140233.DM - Attachment 1

3

Page 4: Attachment 1 Panel Coating Specifications and Cleaning … Dry Film Thickness (nominal) ASTM D1400 0.20 – 0.30 mil primer 0.20 mil primer ... proven fabricators and installers in

3A Composites proudly partners with the most trusted, proven fabricators and installers in the metal wall panel industry. These experts will transform Alucobond® Material into the cladding system best suited for your designand application. The systems illustrated here are representative of typical attachment methods.

There are three ways to contact a sales representative or get more information including samples, literature and binders:1 Call 800.626.3365

2 Complete the “Contact Us” link at www.AlucobondUSA.com

3 Email [email protected]

In as much as the design, construction, installation and all techniques relating to the various uses of Alucobond® Material and Alucobond® Plus Material are under the control of the purchaser, references contained in this brochure to such matters are for concept purposes only. The uses of Alucobond® Material and Alucobond® Plus Material and all activi-ties relating thereto are the responsibility of the purchaser and not the responsibility of 3A Composites USA Inc. Nothing contained herein is intended to or shall be construed as a warranty, express or implied, as to Alucobond® Material and Alucobond® Plus Material. Technical information with reference to Alucobond® Material and Alucobond® Plus Material test results can be obtained by writing 3A Composites USA Inc. Always consult local building codes before use.

Attachment Methods

Rout & Return Dry Seal

Rout & Return Wet Seal

Rain Screen

3A CoMpoSiteS uSA inC. 800.626.3365 [email protected]

08/10 10,000

McCARRAn inteRnAtionAl AiRpoRtLas Vegas, NV

technical Guide

the World’s FavoriteAluminum Composite Material

BR 140233.DM - Attachment 1

4

Page 5: Attachment 1 Panel Coating Specifications and Cleaning … Dry Film Thickness (nominal) ASTM D1400 0.20 – 0.30 mil primer 0.20 mil primer ... proven fabricators and installers in

technical Data Alucobond Alucobond plus Thickness 3mm 4mm 6mm 4mm PlusNominal Weight (lbs/sq.ft) 0.92 1.12 1.59 1.52Coefficient of Expansion x10-5 (in./in.°F) 1.31 1.18 1.24 1.11Temperature Resistance -55° to 175° F (-50° to 80° C)Minimum Peel Strength 115 N mm/mm

tests and Building CodesGuided by the most comprehensive technical support team in the industry, Alucobond® maintains constant and rigorous code compliance. From conceptual vision to finished project, the Alucobond® sales and service professionals will guide you through the process.

north American Building Code AcceptanceAlucobond® and Alucobond® Plus are accepted by the following code regulatory bodies:› IBC › City of New York› City of Los Angeles› Miami-Dade County Florida› National Building Code of Canada (1998)› State of Florida

Material Code tests Alucobond® has successfully passed the following tests:› ASTM E 84 – Surface burning characteristics › ASTM D1929 – Ignition properties› ASTM D1781 – Peel strength› NFPA 285 – Intermediate scale multi-story (Alucobond® Plus only)

Mamaroneck High SchoolMamaroneck, NY

univeRSity oF CAliFoRniARiverside, CA

Global Brand leader

Polyethylene or Fire Retardant Core

0.020" NominalThicknessAluminum Skin

Coil Coated Paint or Anodized Finish

Alucobond ® is the original ACM (aluminum composite material) and is the preferred architectural cladding for façade and corporate identity applications. Alucobond ® Material is available in a wide range of options and dimensions that can be tailored to your specific project. With its hallmark superior flatness, Alucobond ® offers an extensive selection of standard and custom finishes that span the color spectrum.

physical propertiesMaterial Composition› Aluminum facings in 0.020" nominal thickness (interior and exterior to ensure flatness)› Polyethylene core available in 3mm, 4mm and 6mm thicknesses (PE)› Proprietary fire-resistant core available in 4mm thickness only (Plus)

panel Widths panel lengths› Standard widths 50" and 62" (coil coated) › Standard lengths 122", 146" and 196"› Standard widths 50" and 62" (anodized) › Custom lengths up to a maximum of 360"› Custom width 40"

Minimum Bending Radius› The minimum bending radius of Alucobond® and Alucobond® Plus without routing the

interior skin is 15 times the thickness of the material.

Available Finishes› PVDF, FEVE› Polyester› Modified Polyester› Anodized› Monochromatics, Micas and Metallics› Natural

u.S. XpressChattanooga, TN

RiveRvieW iiChicago, IL

GeoRGiA AquARiuMAtlanta, GA

BR 140233.DM - Attachment 1

5

Page 6: Attachment 1 Panel Coating Specifications and Cleaning … Dry Film Thickness (nominal) ASTM D1400 0.20 – 0.30 mil primer 0.20 mil primer ... proven fabricators and installers in

BR 140233.DM - Attachment 1

6

Page 7: Attachment 1 Panel Coating Specifications and Cleaning … Dry Film Thickness (nominal) ASTM D1400 0.20 – 0.30 mil primer 0.20 mil primer ... proven fabricators and installers in

BR 140233.DM - Attachment 1

7