2
COMMERCIAL www.braycommercialdivision.com 1 Bray Controls Commercial Division 13788 West Road, Suite 200A Houston, Texas 77041 [email protected] Phone: 1-888-412-2729 Fax: 1-888-412-2720 COMMERCIAL www.braycommercialdivision.com FN-Series Submittal/Technical Data 1/08/16 FN Series Actuators - For use on ATT PIC Valves Specifications ATT Actuators FN.0.2 FN.0.4 FN.1.2 Supply voltage 24V AC/DC ±10%, 50/60 Hz Motor Bi-directional synchronous (2-position / 3-point floating) Power consumption Input Impedance 3VA 3VA 3VA, 5VA peaks Control signal Analog 0(2)-10V DC Digital Analog 0(2)-10V DC Position output 0(2)-10V DC - 0(2)-10V DC Failsafe function No No Yes >30kΩ - >30kΩ Auto stroke Yes No Yes Operation time 50 Hz: 90 seconds 50 Hz: 90 Seconds 50 Hz: 45 Seconds Actuation force 50 lbf, 225N ±5% 50 lbf, 225N ±5% 50 lbf, 225N ±5% Ambient temperature -0.4°F to +122°F Humidity rating <95% Non Condensing Protection IP54, class II Cable 4 wires 22 AWG halogen free cable, 3.2 feet 3 wires 22 AWG halogen free cable, 3.2 feet 4 wires 22 AWG halogen free cable, 3.2 feet Weight 0.55 lbs 0.55 lbs 0.66 lbs FN.0.2 & FN.0.4 Series FN.1.2 Series Auto Stroke Option With the auto stroke option activated, the actuator will make one full cycle every 24 hours, if the actuator constantly has been in fully open or fully closed position during the previous 24 hours. This operation will clear up any possible impurities accumulated in the valve, and re-calculate the end positions.

ATT Actuators FN.0.2 FN.0.4 FN.1 - Bray Commercial Division · PDF fileFN Series Actuators - For use on ATT PIC Valves Specifications ATT Actuators FN.0.2 FN.0.4 FN.1.2 ... fully

Embed Size (px)

Citation preview

Page 1: ATT Actuators FN.0.2 FN.0.4 FN.1 - Bray Commercial Division · PDF fileFN Series Actuators - For use on ATT PIC Valves Specifications ATT Actuators FN.0.2 FN.0.4 FN.1.2 ... fully

COMMERCIAL

www.braycommercialdivision.com1

Bray Controls Commercial Division13788 West Road, Suite 200AHouston, Texas [email protected]: 1-888-412-2729Fax: 1-888-412-2720

COMMERCIAL

www.braycommercialdivision.comFN-Series – Submittal/Technical Data1/08/16

FN Series Actuators - For use on ATT PIC Valves Specifications

ATT Actuators FN.0.2 FN.0.4 FN.1.2

Supply voltage 24V AC/DC ±10%, 50/60 Hz

Motor Bi-directional synchronous

(2-position / 3-point floating)

Power consumption

Input Impedance

3VA 3VA 3VA, 5VA peaks

Control signalAnalog 0(2)-10V DC

DigitalAnalog 0(2)-10V DC

Position output 0(2)-10V DC - 0(2)-10V DC

Failsafe function No No Yes

>30kΩ - >30kΩ

Auto stroke Yes No Yes

Operation time 50 Hz: 90 seconds 50 Hz: 90 Seconds 50 Hz: 45 Seconds

Actuation force 50 lbf, 225N ±5% 50 lbf, 225N ±5% 50 lbf, 225N ±5%

Ambient temperature -0.4°F to +122°F

Humidity rating <95% Non Condensing

Protection IP54, class II

Cable 4 wires 22 AWG halogenfree cable, 3.2 feet

3 wires 22 AWG halogenfree cable, 3.2 feet

4 wires 22 AWG halogenfree cable, 3.2 feet

Weight 0.55 lbs 0.55 lbs 0.66 lbs

FN.0.2 & FN.0.4 Series FN.1.2 Series

Auto Stroke OptionWith the auto stroke option activated, the actuator will make one full cycle every 24 hours, if the actuator constantly has been in fully open or fully closed position during the previous 24 hours.

This operation will clear up any possible impurities accumulated in the valve, and re-calculate the end positions.

Page 2: ATT Actuators FN.0.2 FN.0.4 FN.1 - Bray Commercial Division · PDF fileFN Series Actuators - For use on ATT PIC Valves Specifications ATT Actuators FN.0.2 FN.0.4 FN.1.2 ... fully

COMMERCIAL

www.braycommercialdivision.com2

Valve model: C, DShown with

FN.0.4, FN.0.2 Actuator

B

A E

Note * Add end connection length to body length.Note ** Weight does not include end connections or actuator.Note *** For valve body.

ModelNumber

ValveModel

ValveSize

CartridgeSize

BodyTappings

A BFC

(FN.0.4 & FN.0.2)

D(FN.1.2)

End connections E** ***Weight

(lbs.)Cv

(GPM)NPTfemale

NPTmale Sweat

ATT-B-050-X-X/Act.ATT-B-075-X-X/Act.

ATT-B-100-X-X/Act.

ATT-B-100-X-X/Act.ATT-B-125-X-X/Act.

ATT-C-050-X-X/Act.

ATT-C-075-X-X/Act.

ATT-C-100-X-X/Act.

ATT-D-100-X-X/Act.

ATT-D-125-X-X/Act.

ATT-D-150-X-X/Act.

B

1/2”

1/4”

1/4”

1/4”

3.23

1.22 5.12 5.71 N/A N/A N/A

1.2

3.03/4” 3.70 1.31”

BSP Only 4.02 1.4

1” H(1-1/2”

dia.)5.04 1.85 6.02 6.50 N/A N/A N/A

4.114.5

1 1/4” 3.7

C

1/2”

L & M (3/4”dia.)

H(1-1/2”

dia.)

L & M (3/4”dia.)

4.80 1.30 5.12 5.71

0.87 0.99 0.791.9 3.03/4” 0.87 0.99 0.79

1” N/A 1.54 0.87

D

1”

6.61 1.62 6.02 6.50

1.38 1.57 1.34

4.7 14.51 1/4” 1.38 1.57 1.461 1/2”

ValveWidth

1.33”1.33”2.33”

BSP Only

2.33”

2.33”

1.84”1.84”1.84”

2.64”

2.64”

2.64”

ActuatorWidth

2.03”

2.03”2.03”

BSP Only

2.03”

2.03”

2.03”

2.03”

2.03”

2.03”

2.03”

2.03” 1.57 1.65 N/A

Valve model: C, DShown with

FN.1.2 Actuator

B

A E

Valve model: BShown with

FN.0.4, FN.0.2 Actuator

C, D† C, D† C, D†FFF

B

A

ATT - Valve/Actuator Dimensions

ATT - Strainer Dimensions

Dimensions may vary, depending on the actuator. Dimensions are shown for the largest spring return actuator currently available.Dimensions are shown in inches and are approximate.

A

C

B

1/2” 3.9 1.1 2.33/4” 3.9 1.1 2.31”

2”

5.3 1.3 2.6

7.7 1.9 3.71 1/4”

7.5 1.9 3.71 1/2”

152025

32

40

50 9.5 1.6 4.3

A B CConnection

in. mm