  • 2011 Interlogix, a UTC Fire & Security Company. All rights reserved. 1 / 56 P/N 1070341 REV 2.0 ISS 22FEB11

    ATS125x Four-Door DGP Installation Sheet

    EN FR IT NL PL SV 1

  • 2 / 56 P/N 1070341 REV 2.0 ISS 22FEB11

    2

    3

    ATS1116

    ATS125x

    ATSC

    P

    1 15 6

    4 4 4 4 4

    222

    33

    33

    3 3

    777

    8 8

    9

  • P/N 1070341 REV 2.0 ISS 22FEB11 3 / 56

    4

    DGP 0

    DGP 4 DGP 5

    1

    ON SD

    2 3 4 1

    ON SD

    2 3 4 1

    ON SD

    2 3 4

    DGP 1 DGP 21

    ON SD

    2 3 4

    DGP 3

    1

    ON SD

    2 3 4 1

    ON SD

    2 3 4 1

    ON SD

    2 3 4

    DGP 61

    ON SD

    2 3 4

    DGP 7

    DGP 8

    1

    ON

    SD

    2 3 4 1

    ON SD

    2 3 4 1

    ON SD

    2 3 4

    DGP 9 DGP 101

    ON SD

    2 3 4

    DGP 11

    1

    ON SD

    2 3 4 1

    ON SD

    2 3 4 1

    ON SD

    2 3 4 1

    ON SD

    2 3 4

    DGP 12

    5

    PCB ATS125x

    12V 0V D+ D- 12V 0V D+ D-

    ATS1170

    ATS1190

    D-D+0V12V

    D-D+0V12V

    12V0VD+D-

    6

    1

    ON SD

    2 3 4 1

    ON SD

    2 3 4 1

    ON SD

    2 3 4 1

    ON SD

    2 3 4

    1 2 3 4

    8

    ATS125x

    1 C 2

    1 2

    7

    PCB ATS4000

    0VD+D-

    0VD+D-

    0VD+D-

    0V D+ D-

    PCB ATS125x

    9

    PCB ATS125x

    NOCNC

    NO

    C

    NC

  • 4 / 56 P/N 1070341 REV 2.0 ISS 22FEB11

    10 1. DGP Options Output Controllers Batch Number System Code Alarm Code Prefix Digits Start Card Number Poll RAS Number of Cards RAS with LCD Start User Number RAS with RTE Toggle RAS Dual Zone Multiple Badge Time Card to PIN Time Re-lock Delay Time Two Cards Time Region Count Limit 2. Door Options Select Door x, x, x, x 1. Access Options Unlock Time Out Reader Card & PIN Extended Unlock Time In Reader No PIN If TZ Shunting Out Reader No PIN If TZ Shunt Time In Reader Inhibit Region 0 Users Extended Shunt Time` Out Reader Inhibit Region 0 Users Shunt Warning Time Anti-Passback Time Shunt Until Door Closed In Region Cancel Shunt After Door Secures Out Region Low Security Timezone In Reader Two Cards In Reader Card & PIN Out Reader Two Cards 2. Request to Exit Options RTE Timezone RTE Times Door Open In RTE Disabled When Armed RTE Reporting Out RTE Disabled When Armed 3. Alarm Control Alarm Group Exit Denied if Area Armed Reader Has No Alarm Control RAS Number Disabled Entry Denied if Area Armed 4. Reader Options Zone Holds Door Unlocked Report Forced Door Door Unlocked Until Door Opens Report DOTL Unlock Timezone Reader LED Options Unlock Timezone After Entry Pulsed Lock & Unlock Relays Report Door closed & locked Time & Attendance Reader Map Open/Unlocked to Unlocked Reader Duress Report Door Open/Close 5. Hardware Options Unlock Relay Number DOTL Zone Zone Number DOTL Output 3. Initialise Database Monitor 2nd Door Zone RTE Zone 4. Display Card Forced Output Number Interlock Zone 5. Door Groups Shunt Zone Areas 6. Reserved Warning Output Number Fault Output Number 7. System Options Mains Fail Output Number Low Battery Output Number Tamper Output Number 8. Macro Logic 9. Version Number 10. To Local Devices

  • P/N 1070341 REV 2.0 ISS 22FEB11 5 / 56

    11 1. Options de DGP Cartes de sortie Numro de lot Code systme Chiffres prfixe code alarme Numro de carte de dpart RAS scruter Nombre de cartes RAS avec LCD Numro utilisateur de dpart RAS avec DDS Basculer RAS Zone double Dure multiple de badge Dure de carte sur NIP Reverrouiller valeur retard Heure deux cartes Limite du nombre de rgions 2. Options de porte Slectionner porte x, x, x, x 1. Options d'accs Dure de dverrouillage Carte et NIP hors lecteur Dverrouillage prolong Aucun NIP si TH dans le lecteur Shuntage Aucun NIP si TH hors lecteur Dure de shunt Dans lecteur exclut util. rn 0 Dure de shunt prolonge Hors lecteur exclut util. rn 0 Dure d'avertissement shunt Dure d'anti retour Shunt jusqu' fermeture porte Dans la rgion Annuler shunt aprs ferm. porte Hors rgion Tranche horaire basse scurit Deux cartes dans le lecteur Carte et NIP dans le lecteur Deux cartes hors lecteur 2. Options de DDS Tranche horaire de DDS DDS temporise porte ouverte Dans DDS dsactive si arm Transmission de DDS Hors DDS dsactive si arm 3. Contrle d'alarme Groupe d'alarme Sortie refuse si groupe arm Lecteur sans contrle d'alarme Numro de RAS dsactiv Entre refuse si groupe arm 4. Options de lecteur Zone maintient porte dver Transmettre porte force Porte dverr. jusqu' ouverture Transmettre DOTL Tranche horaire de dverrouillage Options LED du lecteur Dverrouiller pdt TH aprs 1re entre Relais ver. Consigner ouverture/fermeture de porte Lecteur heure & prsence Affecter activ dverrouill Lecteur de contrainte Transm. porte ouverte/ferme 5. Options matrielles Dverrouiller sortie n Numro de zone DOTL Numro de zone Numro de sortie DOTL 3. Init. base de donnes Surveiller zone de deuxime porte Numro de zone Demande de sortie4. Afficher carte Numro de sortie force Numros de zone sas 5. Groupes de portes Numro(s) de zone de shunt Groupe(s) affect(s) une porte 6. Rserv Numro de sortie d'avertissement Numro de sortie de dfaut 7. Options du systme Numro de sortie de dfaut secteur Numro de sortie de batterie faible Numro de sortie autoprotge 8. Macro logique 9. Numro de version 10. Vers modules locaux

  • 6 / 56 P/N 1070341 REV 2.0 ISS 22FEB11

    12 1. Opzioni DGP Espansioni uscite Numero di batch Codice di sistema Prefisso codice allarme Primo numero di tessera Interrogazione RAS Numero di tessere RAS con LCD Utente prima tessera RAS con RdU Alterna RAS Doppio bilanciamento Tempo comando multiplo Tempo tra tessera e PIN Ritardo blocco serratura Tempo tra due tessere Numero massimo per regione 2. Opzioni varco Seleziona varco x, x, x, x 1. Opzioni di accesso Ora apertura serratura Tessera e PIN per il lettore d'uscita Ora apertura serratura estesa Nessun PIN se FO nel lett. ingr. Inibizione Nessun PIN se FO nel lett. usc. Tempo di inibizione Lett. ingr. escl. utenti reg. 0 Tempo di inibizione esteso Lett. usc. escl. utenti reg. 0 Durata preavviso di inibizione Anti Pass-Back Varco inibito fin quando non viene chiuso Regione del lettore d'ingresso Ann. deriv. dopo chius. varco Regione del lettore d'uscita Fascia oraria di bassa sicurezza Lettore scheda e PIN ingresso Tessera e PIN per il lettore d'ingresso Lettore scheda e PIN uscita 2. Opzioni richiesta di uscita Fascia oraria RTE RdU temporizza apertura varco RTE in entrata disabilitata quando inserita Segnalazione della Richiesta uscita RTE in uscita disabilitata quando inserita 3. Controllo di allarme Gruppi di allarme Uscita negata se larea inserita Il lettore non ha alcun controllo sull allarme Numero di RAS disattivato Entrata negata se larea inserita 4. Opzioni lettore La zona mantiene il varco sbloccato Segnalare la forzatura del varco Serr. porta ap. fino ap. porta Segnala DOTL Fascia oraria varco sbloccato Opzioni del LED del lettore Fascia or. ap. serr. dopo ingr. Rel di blocco e sblocco a impulsi Tras. chiuso & bloccato Lettore di rilevamento presenza Tras. aperto/sbloccato come sbloccato Anticoercizione lettore Segnalare lapertura/chiusura del varco 5. Opzioni hardware Unlock Relay Number Zona DOTL Numero di zona Uscita DOTL 3. Inizializzare il database Controllo della seconda zona del varco Zona RdU 4. Visualizzare la tessera Zona deriv. Numeri di zone per interblocco 5. Gruppi di varchi Numero di zone inibite Aree assegnate al varco 6. Riservato Numero uscita di avviso Numero uscita di guasto 7. Opzioni sistema Uscita mancanza rete Uscita per batteria bassa Uscita tamper 8. Logica macro 9. Numero di versione 10. Ai dispositivi locali

  • P/N 1070341 REV 2.0 ISS 22FEB11 7 / 56

    13 1. DI-opties Uitgangscontrollers Batchnummer Systeemcode Prefix alarmcode Nummer eerste kaart GI's die gepolled worden Aantal kaarten GI's met LCD Eerste gebruikersnummer GI's met RTE ingeschakeld GI's met wisselfunctie Dubbellus Kaart meerdere keren lezen Tijd tussen kaart en PIN-code Vergrendelvertraging Tijd tussen twee kaarten Limiet regioteller 2. Deuropties Deur selecteren x, x, x, x 1. Toegangsopties Ontgrendeltijd UIT lezer vereist kaart en PIN-code Verlengde ontgrendeltijd IN lezer blokkeert PIN als tijdzone actief is Shunting UIT lezer geen PIN als tijdzone Shunttijd IN lezer blokkeert gebruikers regio 0 Verlengde shunttijd UIT lezer blokkeert gebruikers regio 0 Shunt waarschuwingstijd Anti-passback Shunten tot deur is gesloten Regio IN lezer Einde shunt als deur gesloten Regio UIT lezer Tijdzone laag veiligheidsrisico IN lezerfunctie voor twee kaarten IN lezer vereist kaart en PIN-code UIT lezerfunctie voor twee kaarten 2. Request To Exit opties Tijdzone uitgangsverzoek RTE openingstijden In RTE niet actief bij ingeschakeld gebied Rapportage uitgangsverzoek Uit RTE niet actief bij ingeschakeld gebied 3. Alarmcontrole Alarmgroep Geen UIT als ingeschakeld Lezer heeft geen alarmcontrolefunctie GI-nummer uitgeschakeld Geen toegang bij ingeschakeld gebied 4. Lezeropties Uitgang houdt deur ontgrendeld Geforceerde deur rapporteren Deur ontgrendeld tot deze geopend wordt Meld DTLO Tijdzone ontgrendeling LED opties van lezer Tijdzone ontgrendeling na entree Pulsvergrendeling/ontgrendeling Melding gesloten en ontgrendelde deur Tijd en aanwezigheidslezer Geopende/ontgrendelde deur rapporteren Dwangfunctie Rapporteren openen en sluiten 5. Hardwareopties Nummer ontgrendelrelais DOTL ingangsnummer Ingangsnummer DOTL uitgangsnummer 3. Database initialiseren Ingang tweede deur controleren Ingangsnummer uitgangsverzoek 4. Toon kaart Uitgangsnummer geforceerde deur Ingangsnummers sluis 5. Deurgroepen Shuntingangsnummer(s) Gebieden(en) toegewezen aan deur6. Gereserveerd Waarschuwingsuitgangsnummer Uitgangsnummer foutmelding 7. Systeemopties Uitgang netspanningsuitval Uitgang Accu laag Uitgang Sabotage 8. Macro logica 9. Versienummer 10. Naar lokale remote units

  • 8 / 56 P/N 1070341 REV 2.0 ISS 22FEB11

    14 1. Opcje MZD Kontrolery wyj Numer serii Kod systemowy Liczba cyfr prefiksu kodu alarm. Numer pocztkowej karty Odpytywanie ZAZ Liczba kart ZAZ z LCD Numer pocztkowego uytkownika ZAZ z wczonym daniem wyjcia ZAZ z wczon zamian Linia dualna Interwa dla wielu kart Czas podania kodu PIN karty Opnienie przed zamkniciem Interwal dla dwch kart Limit licznika regionu 2. Opcje drzwi Wybierz drzwi x, x, x, x 1. Opcje dostpu Czas otwarcia Czytnik wyjciowy: karta i PIN Przeduony czas otwarcia Czytnik wejc. bez PIN jeli TZ Blokowanie Czytnik wyjc. bez PIN jeli TZ Czas blokowania Czytnik wejc. blokuje region 0 Przeduony czas blokowania Czytnik wyjc. blokuje region 0 Czas ostrzegania o blokowaniu Anti-passback Blokowanie a do zamknicia drzwi Region wewntrzny Anuluj blok. gdy drzwi chronione Region zewntrzny Okres TZ niskiego poziomu ochrony Czytnik wejciowy: dwie karty Czytnik wejciowy: karta i PIN Czytnik wyjciowy: dwie karty 2. Opcje dania wyjcia Okno czasowe Przyc.Wyj Czas otwarcia drzwi przyciskiem wyj Blok. wewn.P.Wyj gdy zazbrojony Raportowanie Przyc.Wyj Blok. zewn.P.Wyj gdy zazbrojony 3. Sterowanie alarmem Grupa alarmowa Brak wyjcia, gdy strefa zazbr. Czytnik nie ma kontroli alarmu Numer ZAZ zablokowany Brak wstpu, gdy strefa zazbr. 4. Opcje czytnika Linia utrzymuje otwarcie drzwi Raport wymuszonego otwarcia Otwarcie drzwi dopki otwarte Raport DOTL Okno czasowe otwarcia Opcje diod LED czytnika Otwarcie OknCzas tylko gdy uytk. 2-pulsowy przekanik drzwi Raport drzwi normalne/aktywne Czytnik kontroli czasu pracy Przydzia aktywne do otwarte Przymus czytnika Raport drzwi otwarte/zamknite 5. Opcje sprztu Numer przekanika otwarcia Numer linii DOTL Numer linii Numer wyjcia typu DOTL 3. Inicjowanie bazy danych Monitorowanie drugiej linii drzwi Numer linii dania wyjcia 4. Pokazywanie karty Numer wyjcia typu wymuszenie Numery linii wspzalenych 5. Grupy drzwi Numery linii blokowanych Obszar(y) przydzielone do drzwi 6. Zarezerwowane Numer wyjcia typu ostrzeenie Numer wyjcia typu uszkodzenie 7. Opcje systemu Numer wyjcia stanu uszkodzenie zasilania Numer wyjcia stanu wyadowany akumulator Numer wyjcia sabotaowego 8. Programowanie makr 9. Numer wersji 10. Do urzdze lokalnych

  • P/N 1070341 REV 2.0 ISS 22FEB11 9 / 56

    EN: Installation Sheet

    Description This manual provides information for the following four-door access control data gathering panel (DGP): ATS1251, ATS1252, ATS1253 and ATS1254. When referring to the four-door DGP, this can be read as any variant of the ATS125x, unless specifically stated otherwise.

    Table 1: List of existing four-door DGP variants

    Variant Auxiliary power

    Locks power

    Housing Dimensions

    ATS1251 12 V 12 V ATS1642 (big) 480x464x160 mm

    ATS1252 12 V 24 V* ATS1642 (big) 480x464x160 mm

    ATS1253 12 V 12 V ATS1640 (small) 445x315x90 mm

    ATS1254 12 V 24 V* ATS1640 (small) 445x315x90 mm

    * In case of 24 VDC variant always use 2 batteries in series.

    ATS125x four-door DGP overview Figure 1 legend

    Item Description

    1. DIP switches (see DIP switch settings on page 12).

    2. RAM or IUM (optional).

    3. EPROM (factory fitted).

    4. KILL jumper - Factory default ATS125x when shorted.

    5. Battery fuse F1.

    6. Auxiliary power fuse F2.

    7. Databus 1 fuse F3.

    8. Databus 2 fuse F4.

    9. Lock power 1 fuse F5.

    10. Lock power 2 fuse F6.

    11. Siren / switch fuse F7

    12. L1-L4 LED

    13. TERM 1. Use this link to terminate the system databus.

    14. TERM 2. Use this link to terminate the local databus, connection 1 on terminal CON9.

    15. TERM 3. Use this link to terminate the local databus, connection 2 on terminal CON10.

    16. CON14 Input expander connector

    17. CON15 Output expander connecter

    18. Mains terminal

    Connections

    Table 2: ATS125x connections

    Terminal block

    Wire Description

    CON1 , Mains power connection System earth (see details on page 11).

    +, 2 x 12 V batteries, 7.2 Ah (24 V version)* 1 x 12 V battery, 7.2 Ah (12 V version)

    Terminal block

    Wire Description

    CON2 +, Aux. power +, Aux. power S+, S ** External siren output CON3 +, Lock 1 power +, Lock 2 power CON4 NO, COM, NC Door 1 relay

    NO, COM, NC Door 2 relay

    CON5 NO, COM, NC Door 3 relay

    NO, COM, NC Door 4 relay

    CON6 0V, D+, D System databus and panel tamper wiring (see ATS system databus connection on page 11 for details).

    T, C Tamper switch

    CON7 1, 2, 3, 4 Zone 1-4 inputs

    C Common

    CON8 5, 6, 7, 8 Zone 5-8 inputs

    C Common

    CON9 12V, 0V, D+, D Local databus to connect RASs and DGPs (see ATS125x local databus and earth connection on page 11 for details).

    CON10 12V, 0V, D+, D Local databus to connect RASs and DGPs (see ATS125x local databus and earth connection on page 11 for details).

    * In case of 24 VDC variant always use two batteries in series. ** External siren output is a supervised output. Typical EOL resistor

    is 1 k.

    Mains power connection

    Use the mains terminal to connect the mains-supply. A fixed cable, or a flexible mains lead to an earthed mains outlet, can be used. In case fixed wiring is used, insert a dedicated circuit breaker in the power distribution network.

    WARNING: Electrocution hazard. To avoid personal injury or death from electrocution, remove all sources of power and allow stored energy to discharge before installing or removing equipment.

    Battery removal/disposal This product contains one (or more) sealed, rechargeable, BS-type lead-acid battery. It is a maintenance-free, leakproof, long-life battery that should not be removed under normal circumstances. Because removing the battery may affect the product's configuration settings or trigger an alarm, only a qualified installer should remove the battery.

    To remove the battery, do the following:

    1. Make sure that your product settings allow you to open its cover without starting the tamper alarm.

    2. Switch off the mains power, if necessary, and remove the cover.

  • 10 / 56 P/N 1070341 REV 2.0 ISS 22FEB11

    3. Disconnect the battery, sliding the product's wires off the wire connectors. Note, that depending on the battery model, the connectors can be located differently.

    4. Remove the battery from the holder.

    For proper recycling, dispose of all batteries as required by local ordinances or regulations. See the specifications for your product or contact technical support for information on replacement batteries.

    Important notes on mounting Mount the unit using screws or bolts through the four mounting holes in the base.

    Ensure that the unit is mounted on a flat, solid, vertical surface so that the base will not flex or warp when the mounting screws/bolts are tightened.

    Allow 50 mm clearance between the equipment enclosures mounted side by side, and 25 mm between the enclosure and the sidewall.

    Only use units in a clean environment and not in humid air.

    LEDs

    Table 3: ATS125x LEDs

    LED Description

    RST OFF: the microprocessor is functioning normally.

    ON: the system is in the reset state.

    Rx1 Flashing LED indicates polling data is being received from the ATS control panel on the system databus.

    Tx1 Flashing LED indicates the four-door DGP is replying to polling from the ATS control panel on the system databus.

    Rx Flashing LED indicates remote units (readers/interfaces) replying to polling.

    Tx Flashing LED indicates the four-door DGP is polling remote unit(s) (readers/interfaces) on the ATS125x local databus. The Tx LED should always be active.

    L1 to L4 Indicates Unlock Relay is active.

    General installation guidelines The ATS125x DGP has been designed, assembled and tested to meet the requirements related to safety, emission and immunity with respect to environmental electrical and electromagnetic interference, as of current relevant Standards.

    If the following guidelines are followed, the system will give many years of reliable service.

    In addition to the following guidelines, during the installation of the ATS125x DGP, it is essential to follow any country dependent installation requirement of local applicable standard. Only a qualified electrician or other suitable trained and qualified person should attempt to wire this system to the mains or to the public telephone network.

    Ensure that there is a good earth available for the alarm system.

    Maintain a separation between low voltage and mains supply cables. Use separate points of cable entry to the control panel cabinet.

    If the upper and/or lower cabinet entry cable holes are used to route wiring into the control panel, always use a proper pipe fitting system by means of an appropriate conduit and junction box. For this purpose, use only materials of suitable flammability class (HB or better).

    For mains power connection, use the mains connector terminal either through a permanent wiring or a flexible mains cable to an earthed mains outlet. Always use cable ties to fix mains cable, at the dedicated fixing point provided near the mains terminal connector.

    - In case of permanent fixed wiring, insert an easily accessible, dedicated bipolar circuit breaker in the power distribution network.

    - Never attempt to solder mains connection wires end where they will be wired to the terminal connectors.

    Avoid loops of wire inside the control panel cabinet and route cables so that they do not lie on top or underneath the printed circuit board. The use of cable ties is recommended and improves neatness of the wiring within the box.

    The battery used with this unit, must be made of materials of suitable flammability class (HB or better).

    Any circuit connected either directly to the on board relays contact or to external relays contact through the on board electronic output, must be of SELV (safety extra-low voltage) operating circuit.

    - Mains switching relay must not be fitted inside the control panel cabinet

    - Always place a suppression diode (e.g. a 1N4001) across the relay coil

    - Use only relay with good insulation between the contacts and the coil.

    The minimum clearance between equipment closures is 50 mm (between equipment vents).

    Only use units in a clean environment and not in humid air. See Specifications on page 14 for more details on the environment.

    Cabling

    System databus preferred wiring

    The TERM link is on the first and last devices on the system databus. In a star-wiring configuration, the TERM link is only fitted on the devices at the ends of the two longest system databus cable runs.

    Figure 2 legend

    Item Description

    1. GND link (do not fit).

    2. Earth lug to connect shield.

    3. ATS4000 control panel.

    4. ATS4000 TERM link fitted (first device on system databus).

    5. Preferred data cable type is WCAT 52 (2-pair twisted).

    6. ATS1110 LCD RAS (TERM switch not set to On).

    7. Separate 12 V power supply. Required if RAS is more than 100 m from the nearest panel or DGP. Connect to of the databus.

  • P/N 1070341 REV 2.0 ISS 22FEB11 11 / 56

    Item Description

    8. ATS125x TERM link fitted (last device on system databus).

    9. ATS125x four-door DGP

    Note: The local databus (not shown) has the same requirements. The local databus is connected to CON9/CON10 of the ATS125x.

    See ATS system databus connection, ATS125x local databus and earth connection, and earthing details below.

    Earthing

    WARNING: Correct earthing procedure must be followed.

    Earthing of one cabinet containing several devices

    All devices designed for the system have earth connections via metal studs to the metal housing. Take care that these metal studs have a good connection to the housing (beware of paint).

    The earth connections of each piece of equipment in the system can be used to connect the shielding of shielded cables.

    If a device is placed in a plastic housing, the earth lug of this device also has to be connected, except for devices, which are not provided with an earth lug.

    Earthing panels in a single building

    In a single building several cabinets or devices are earthed. A licensed contractor must check the safety earth of this building.

    Earthing panels in more than one building

    If the wiring extends to separate buildings, use more than one common earth system. Use the ATS1740 isolator/repeaters to isolate the system databus. This protects the system against variations in earth potential.

    Shielding The shielding of all shielded cables used in the system should only be connected on ONE side to one common earthing point in a building. If a shielded databus cable is routed via more than one plastic device, the shielding from the in-coming and out-going cable must be connected.

    Figure 3 legend

    Item Description

    1. Mains power with local earth

    2. Mains power connector

    3. System databus

    4. Earth lug

    5. Building 1

    6. Building 2

    7. Device in metal housing

    8. Device in plastic housing

    9. ATS control panel

    ATS system databus connection See Figure 7.

    The system databus is used to connect DGPs (such as ATS125x) and arming stations to the ATS control panel. Remote devices can be up to 1.5 km from an ATS control panel.

    Each remote device is assigned an address and is polled in sequence by the ATS control panel. Up to 12 four-door DGPs can be connected on the main ATS system databus.

    Arming stations and DGPs must be connected via a 2-pair twisted shielded data cable from the system databus connection (WCAT 52 is recommended).

    Connect the shield of the data cable to earth at the ATS control panel. It should be left disconnected at the other end.

    The four-door DGPs have their own built-in power supply and do not require power from the databus. Only the D+, D and 0 V connections are required between the ATS control panel and a four-door DGP.

    ATS125x local databus and earth connection See Figure 5.

    The ATS125x allows for 16 arming stations (LCD-RASs, Smart Card readers) to be connected to the local databus (CON9/CON10).

    The ATS125x local databus consists of 2 electrically independent loops. If there is a failure in one loop, the other loop can still communicate with the remote devices. The location of devices on the first or on the second loop has no influence on the functionality, as both loops behave as one databus.

    Wire the door contacts and Request-to-Exit buttons associated with each door to the ATS125x inputs.

    Any zone used for DOTL (Door Open Too Long) cannot have any wiring connected.

    Each unit is assigned an address and is polled in sequence by the ATS125x on each loop. Remote units can be located anywhere up to 1.5 km from the ATS125x. Each loop must have termination on both ends.

    Table 4: ATS1190 wiring

    12V Red D+ White

    0V Black D Green

    Connection door contact and Request-to-Exit button

    Figure 8 legend

    Item Description

    1. Door contact

    2. Request-to-Exit button (push button)

    Door lock connection

    See Figure 9.

  • 12 / 56 P/N 1070341 REV 2.0 ISS 22FEB11

    DIP switch settings DIP switches 1 to 4 (DGP address) are used to identify this DGP to the Advisor Master control panel, i.e. Assign the DGP address. A four-door DGP can only be addressed, as DGPs 1 to 12. See Figure 4.

    DIP switches 5 and 6 are used for zone expansion configuration. Figure 6 legend

    Item Description

    1. 8 onboard inputs (no expanders)

    2. 8 onboard inputs + 1xATS1202

    3. 8 onboard inputs + 2xATS1202

    4. 8 onboard inputs + 3xATS1202

    DIP switches 7 and 8 are not used.

    Zones, RASs and outputs

    Numbering

    All DGPs, zones, RASs and outputs are numbered according to a set formula. This is used when determining the physical numbers/locations of DGPs, outputs etc. during programming.

    Table 5: Zones, RASs and outputs allocated per DGP

    DGP / panel Zones / RASs / outputs

    DGP / panel Zones / RASs / outputs

    Control panel 116 DGP 7 113128

    DGP 1 1732 DGP 8 129144

    DGP 2 3348 DGP 9 145160

    DGP 3 4964 DGP 10 161176

    DGP 4 6580 DGP 11 177192

    DGP 5 8196 DGP 12 193208

    DGP 6 97112

    Zones

    A four-door DGP has a maximum of 16 zones available (or 32 zones, if occupies 2 addresses). These zones follow the standard zone numbering.

    For example: ATS125x 1 is DGP1 and has 16 zones, which the ATS control panel identifies as zones 17 to 32.

    If all 32 zones are used, the next DGP address is not available.

    For example: DGP1: zones 17-48, DGP2 is not available, DGP3: zones 49-64.

    See Table 7 and Table 8 for more details on default zone and unlock relay settings.

    Note: The ATS125x four-door DGP has only 8 zones on board. Another 24 zones can be connected with ATS1202 zone expanders.

    RASs

    Card readers, keypads (ATS110x, ATS115x), and ATS1170 are polled as RASs. Polling allows the RAS to transfer data to the ATS125x. RASs are connected to the ATS125x local databus. Each RAS has a unique number in the system depending on four-door DGP address and RAS address on local databus. See Table 5 above for more details.

    16 RASs can be connected to each ATS125x local databus. The RAS addresses relate to specific doors on the ATS125x, and to the reader location if readers are mounted on both sides of the same door.

    Table 6: RAS address and reader function

    IN IN OUT OUT

    Door 1 1 5 9 13

    Door 2 2 6 10 14

    Door 3 3 7 11 15

    Door 4 4 8 12 16

    Outputs

    The four-door DGP has one output available as a switched power output (external siren output). There are also four on-board unlock relays available, one for every door (K1 to K4).

    A four-door DGP can address 48 outputs in total using macro logic.

    Output controllers are used to expand the number of outputs on a DGP. Each output controller expands the outputs by eight. Output and zone numbers are always the same as the first 16 zone numbers on the DGP to which they are connected.

    Outputs devices

    ATS1810: Four-way relay card allows the use of output numbers 5 to 8 of the outputs allocated to the DGP address. For example, DGP 1 uses unlock relays 17 to 20 for opening doors, and outputs 21 to 24 are available on the relay card.

    Note: This card cannot be used together with ATS1811/ATS1820 clocked output cards.

    ATS1811: Eight-way relay cards allow use of output numbers 5 to 48 of the outputs allocated to the DGP address. For example, DGP 1 uses unlock relay 17 to 20 for opening doors, and outputs 21 to 63 are available on the relay cards.

    ATS1820: 16-way open collector card. It is the same as ATS1811.

    The four-door DGP can activate outputs 33 to 63 only by utilizing macro logic.

    When using more than two ATS1811 or ATS1820, use a separate power supply.

    ATS125x default zone and relays settings

    Table 7: ATS125x defaults

    Door 1 Door 2 Door 3 Door 4

    Door contact 1 3 5 7

    Request-to-Exit zone 2 4 6 8

    DOTL 9 10 11 12

    Door relay K1 K2 K3 K4

    The zone numbers in this table refer to the physical zone numbers on the ATS125x PCB.

    The system zone numbers relating to these functions for each of the ATS125x can be found in Table 5.

  • P/N 1070341 REV 2.0 ISS 22FEB11 13 / 56

    Door numbering

    Door numbers are determined by:

    The RAS or reader address when connected to the ATS system databus (doors 1 to 16).

    Four-door DGP address (doors 17 to 64).

    Doors 1 to 16 are reserved for RAS 1 to 16 and are connected to the ATS system databus. These only provide basic access control (door opening).

    Doors 17 to 64 are used for door numbers and are controlled by a four-door DGP (ATS125x). These doors provide enhanced access control functions (anti-passback, etc).

    Table 8: Door numbers allocated per DGP

    Device address Door number

    RAS 1 to 16 1 to 16 (door open only)

    1 2 3 4

    DGP 1 17 18 19 20

    DGP 2 21 22 23 24

    DGP 3 25 26 27 28

    DGP 4 29 30 31 32

    DGP 5 33 34 35 36

    DGP 6 37 38 39 40

    DGP 7 41 42 43 44

    DGP 8 45 46 47 48

    DGP 9 49 50 51 52

    DGP 10 53 54 55 56

    DGP 11 57 58 59 60

    DGP 12 61 62 63 64

    Power-up procedure When the installation is complete, ensure that the unit is addressed correctly using DIP switches 1 to 4 (1 to 12 are available).

    Check if the RAM memory in the ATS125x and the Advisor Master control panel is the same.

    On initial power-up, the LEDs on the four-door DGP should indicate as follows:

    RST LED: Off.

    ATS system databus indicator LEDs:

    Rx1: Flashes if the ATS125x receives polling from the ATS control panel.

    Tx1: Off if the ATS125x is not addressed or is not programmed to be polled by the control panel.

    Four-door DGP local databus indicator LEDs:

    Tx: Flashes when the ATS125x is polling remote devices (readers/interfaces) on the local databus; TX should always be active.

    Rx: Flashing indicates remote devices reply to polling.

    Setup procedure The minimal setup only consists of settings required to activate the DGP and the connected RASs for programming.

    1. Set addresses of RASs (readers or keypads) connected to the local databus of the four-door DGP

    2. In the Advisor Master control panel, installer programming (menu 19.4): DGP, activate polling for the four-door DGP and set the DGP type.

    How to access the ATS125x programming menu

    Access to the Door programming menu is via the Advisor Master, Installer menu 28, To remote devices. When programming in the four-door programming menu, you are actually programming the ATS125x.

    If you are denied access to To remote devices, it is because one or more of the above hardware or programming criteria have not been met.

    1. The display shows:

    Remote Device: 1-DGP, 2-RAS Device:

    Enter the type of remote device you wish to program. Select 1 (DGP).

    2. Enter the number of the remote device you wish to program. The DGP number is the same as the DGP address.

    Remote DGP Setup DGP No.:

    The following is briefly displayed:

    Connecting Enter to Abort

    You have now accessed the ATS125x Programming menu for the ATS125x that you have selected. The display shows the four-door programming menu display:

    # Move On * Move back Menu:

    ATS125x programming menus # Menu Description

    1. DGP Options Global options valid for all doors of the selected four-door DGP.

    2. Door Options Options valid for each individual door on the ATS125x.

    3. Initialise Database Allows initialisation of door database. Resets all data in the DGP to default.

    4. Display Card Displays card details on LCD for the last card that is badged.

    5. Door Groups Allows door group details to be viewed.

    6. Reserved

    7. System Options Allows ATS125x outputs to be activated to indicate system faults on the ATS125x.

    8. Program Macro Logic

    Enables outputs and internal events to be generated by logic functions using ATS125x events.

    9. Version Number ATS125x firmware and CPLD version number.

  • 14 / 56 P/N 1070341 REV 2.0 ISS 22FEB11

    # Menu Description

    10. To Local Devices Enables you to access the remote devices on the local databus.

    Note: CARD FORMAT only can be configured via management software.

    See also Programming Map in Figure 10.

    Initialise Database

    Initialise the four-door DGP on initial power up only. This is done via menu option 3, Initialise database.

    Caution: All programming and settings will be reset to factory defaults. Factory defaults are listed in the ATS125x programming guide.

    Poll connected RASs

    Go to menu 1, DGP options.

    Set or select the following options:

    1. Enter RASs connected to be polled. 2. Enter LCD RAS connected.

    For more details on how to program the ATS125x four-door DGP refer to the ATS125x Programming Guide.

    Troubleshooting

    ATS system data bus indicator LEDs Rx1 The yellow Rx1 LED flashes to indicate polling data is

    received on the system data bus from the panel. If the Led does not flash, the control panel is not operational or the bus is faulty

    Check that DGP is powered correctly.

    Check wiring DGP data bus connections.

    Tx1 The red Tx1 LED flashes to indicate the DGP is replying to polling from the control panel. If the Rx1 LED flashes but the Tx1 LED does not, the DGP is not programmed to be polled in the control panel or has a wrong address.

    Check if the DGP connected to the data bus has correct address.

    Check that the DGP is being polled (Advisor Master control panel menu 19.4).

    Four-door DGP local data bus indicator LEDs Tx The red Tx LED flashes when the ATS125x is polling

    remote devices (readers/interfaces) on the local databus. Tx LED should always be active.

    Rx The yellow Rx LED flashes to indicate remote devices reply to polling.

    If the LED does not flash, the RASs are not programmed to be polled, addressed incorrectly or the bus is faulty.

    Check that RASs are powered correctly.

    Check wiring RAS data bus connections.

    Check that the RASs (readers/interfaces) are polled (ATS125x menu 1.4 Poll RAS).

    Check that RASs are addressed correctly.

    Specifications ATS1251

    ATS1253 ATS1252 ATS1254

    General specifications

    End of line resistor Default: 4.7 k, 2 %, 0.25 W (Other: 10 k, 2 %, 0.25 W; 2.2 k, 2%,

    0.25 W)

    Housing See Table 1 on page 9

    PCB 202 x 218 x 48 mm

    Colour Beige

    Operating temperature

    10 to +55C

    Humidity 95% non condensing

    IP protection grade IP30

    Mains power specifications

    Mains input voltage 230 V~ 10%, 50 Hz 10%, 129 VA max. Current consumption at 230 V~

    560 mA max.

    Main board supply voltage (J17)

    30 V~ typical

    Power supply specifications

    Power supply voltage 13.8 0.2 V 27.6 0.2 V Power supply current 4.0 A max. at 13.8

    0.2 V 1.6 A max at 27.6 V

    + 1.1 A max at 13.8 V

    Auxiliary power output

    13.8 0.2 V, 2 A max. Note: Maximum permanent current to power devices external to the control equipment in the absence of alarm conditions.

    Battery power output 13.8 0.2 V 27.6 0.2 V Battery type Lead acid rechargeable

    Max. battery capacity ATS1251: 1 x 26 Ah

    ATS1253: 1 x 7.2 or 1 x 18 Ah

    ATS1252: 2 x 26 Ah

    ATS1254: 2 x 7.2 Ah

    Main board consumption

    100 mA at 13.8 0.2 V

    Remaining current 3.9 A at 13.8 V 1.6 A max at 27.6 V +1 A max at 13.8 V

    Notes:

    Remaining current means all available current that can be used for the following: Auxiliary power (incl. switched), Battery charge, Lock power and Local comms power. You can distribute the total available current over the terminals as long as the maximum remaining current and fuse rating for each output is respected.

    The needed battery current is dependant on the approval grade. See Auxiliary current and battery capacity on page 15 for determining which current should be reserved for charging the battery. Note that Auxiliary power, Lock power and Local comms power is limited by the battery current.

    For the 12 V variant 3900 mA can be distributed. Higher current value drives the power supply into current limit.

    For the 24 V variant 1600 mA can be distributed over 27.6 V contacts (Locks and Battery) and 1000 mA can be distributed over the 13.8 V contacts (Auxiliary power incl. Switched and the Local Comms).

    Fuses F1: Battery 1 5 A, Fast 20x5

    F2: Auxiliary power 1 A, Fast 20x5

  • P/N 1070341 REV 2.0 ISS 22FEB11 15 / 56

    F3: Local databus 1 800 mA, Fast 20x5

    F4: Local databus 2 800 mA, Fast 20x5

    F5: Lock power 1 2 A, Fast 20x5

    F6: Lock power 2 2 A, Fast 20x5

    F7: Switched power 1A, Fast 20x5

    Mains*: Mains fuse 800 mA, Slow 20x5

    *Mains fuse is part of the mains terminal block.

    WARNING: Before removing the mains fuse, the mains power must be disconnected! See Mains power connection on page 9.

    Auxiliary current and battery capacity

    Note: This is only a reference to approval requirements. Please contact your local sales office for more information about valid certification.

    Table 9: 12 V variants auxiliary current and battery capacity

    Approval grade

    Discharge time (h)

    Charge time (h)

    Max Available Auxiliary Current (mA)

    Battery Type:* 7.2Ah 18Ah 26Ah

    EN 1&2 12 72 450 1300 1800

    EN 3&4 60 24 = 175 290

    NF&A2P-2 36 30 = 330 500

    NF&A2P-3 72 30 = 110 200

    VdS-B 30 24 110 450 700

    VdS-C 60 24 = 175 290

    * Available battery capacities depend on the housing as well. Please refer to max. battery capacity in Table 1 on page 9.

    Table 10: 24 V variants auxiliary current and battery capacity

    Approval grade

    Discharge time (h)

    Charge time (h)

    Max Available Auxiliary Current (mA)

    Battery Type:* 2 x 7.2Ah

    2 x 18Ah

    2 x 26Ah

    EN 1&2 12 72 500 1400 1800

    EN 3&4 60 24 = 200 300

    NF&A2P-2 36 30 100 400 600

    NF&A2P-3 72 30 = 150 250

    VdS-B 30 24 120 500 730

    VdS-C 60 24 = 200 300

    * Available battery capacities depend on the housing as well. Please refer to max. battery capacity in Table 1 on page 9.

    All Auxiliary currents mentioned in the tables above are calculated for the 24 V auxiliary. For calculation of the maximum load on 12 V auxiliary outputs a correction factor of 1.6 should be taken into account.

    Formula: Iaux at 12 V = Iaux at 24 V x 1.6

    Example 1:

    One wants to meet Approval grade EN 1&2 with two 18 Ah batteries. The application has a maximum load of 24 V Locks of 800 mA. According Table 10 above it means that the max available auxiliary current is 1400 mA at 24 V.

    This means that besides the 800 mA for the 24 Locks either:

    1400 800 = 600 mA is left at 24 V Aux, or

    600 x 1.6 = 960 mA left at 12 V Aux i.e. AUX power, Locale Comms.

    Example 2:

    One wants to meet Approval grade NF&A2P-2 with two 18 Ah batteries. The application has a maximum Local Comms load (12 V) of 200 mA. According Table 10 above it means that the max available auxiliary current is 400 mA at 24 V.

    This 200 mA at 12 V Local Comms load results in:

    200 / 1.6 = 125 mA at 24 V, and this leaves 400 125 = 275 mA @24 V for Aux (i.e. Locks power).

    Restrictions:

    Max 12 V Aux current: 1000 mA. Max 24 V Aux current: 1600 mA.

    Maximum auxiliary current can be limited by:

    Discharge duration Available charge capacity for battery Auxiliary fuse

    All data based on board without external equipment.

    Cabling distance

    Table 11: Cabling distance

    From To Distance Cable type

    ATS control panel system databus (J10)

    ATS125x system databus (CON6)

    1.5 km (total databus length without repeaters)

    WCAT 52 or equivalent

    Local databus 1 (CON9)

    RAS 1.5 km (total databus length without repeaters)

    WCAT 52 or equivalent

    Local databus 2 (CON10)

    RAS 1.5 km (total databus length without repeaters)

    WCAT 52 or equivalent

    External terminals specification

    Table 12: External terminals

    Termi-nal block

    Wire Description Min Typ Max Unit

    CON1 , AC transformer connection

    20 120

    VACVA

    +, Battery connection 12V variant (ATS1251, ATS1253)

    13.6 13.8 7.2

    14.0 25

    VAh

    Battery connection 24V variant (ATS1252, ATS1254)

    27.4 27.6 2 x 7.2

    27.8 2 x 25

    VAh

    CON2 +, , +,

    Auxiliary power output 13.6 13.8 14.0 2

    VA

    S+, S

    External siren output 13.6 13.8 14.0 1

    VA

    CON3 +, , +,

    Lock power output 12V variant (ATS1251, ATS1253)

    13.6 13.8 14.0 2

    VA

    Lock power output 24V variant (ATS1252, ATS1254)

    27.4 27.6 27.8 2

    VA

  • 16 / 56 P/N 1070341 REV 2.0 ISS 22FEB11

    Termi-nal block

    Wire Description Min Typ Max Unit

    CON4, CON5

    C, NO or NC

    Contacts door relays (each)

    30 2

    VA

    CON9, CON10

    +12 V Power for local bus 13.6 13.8 14.0 2

    VA

    Notes

    Maximum total current consumption for auxiliary power outputs (++/) and external siren should not exceed 2 A.

    Maximum total current consumption should not exceed 3 A, including battery load current.

    Regulatory information Manufacturer UTC Fire & Security Americas Corporation, Inc.

    1275 Red Fox Rd., Arden Hills, MN 55112-6943, USA

    Authorized EU manufacturing representative: UTC Fire & Security B.V. Kelvinstraat 7, 6003 DH Weert, Netherlands

    Certification

    European Union directives

    1999/5/EC (R&TTE directive): Hereby, UTC Fire & Security declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.

    2002/96/EC (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info.

    Contact information www.utcfireandsecurity.com or www.interlogix.com

    FR: Instructions dinstallation

    Information importante Ce manuel fournit les informations sur les DGP 4 portes suivants: ATS1251, ATS1252, ATS1253 et ATS1254. Le terme de DGP 4 portes, se rapporte nimporte quel modle de ATS125x, moins dindication spcifique.

    Tableau 1: Liste des modles de contrleurs 4 portes

    Rf. Alim. auxiliaire

    Alim. ventouses

    Coffret Dimensions

    ATS1251 12 VDC 12 VDC ATS1642 grand 480x464x160 mm

    ATS1252 12 VDC 24 VDC * ATS1642 grand 480x464x160 mm

    ATS1253 12 VDC 12 VDC ATS1640 petit 445x315x90 mm

    ATS1254 12 VDC 24 VDC * ATS1640 petit 445x315x90 mm

    * Utiliser 2 batteries 12 V en srie.

    Prsentation du DGP 4 portes ATS125x

    Figure 1 lgende

    Numro Description

    1. Commutateurs DIP dadressage (voir Configuration des commutateurs DIP en page 19).

    2. RAM ou IUM (optionnel).

    3. EPROM (installe en usine).

    4. KILL - Retour aux paramtres usine de l'ATS125x.

    5. Fusible batterie F1.

    6. Fusible d'alimentation aux. F2.

    7. Fusible du bus de donnes 1, F3.

    8. Fusible du bus de donnes 1, F4.

    9. Fusible dalimentation ventouse 1, F5.

    10. Fusible dalimentation ventouse 2, F6.

    11. Fusible sirne, F7

    12. LEDs L1-L4

    13. TERM 1. Utilisez ce cavalier pour terminer le bus de donnes du systme.

    14. TERM 2. utilisez ce cavalier pour terminer le bus de donnes local, connexion 1 du bornier CON9.

    15. TERM 3. utilisez ce cavalier pour terminer le bus de donnes local, connexion 2 du bornier CON10.

    16. CON14 Connecteur dextension dentres

    17. CON15 Connecteur dextension de sorties

    18. Bornier secteur

    Connexions

    Tableau 2: Connections ATS125x

    Conn. Bornes Description

    CON1 , Connexion au secteur Terre du systme (voir Mise la terre en

    page 18)

    +, Batteries 2 x 12 V, 7.2 Ah (version 24 V) * Batteries 1 x 12 V, 7.2 Ah (version 12 V)

    CON2 +, Sortie dalimentation auxiliaire +, Sortie dalimentation auxiliaire S+, S ** Sirne externe CON3 +, Alimentation ventouse 1 +, Alimentation ventouse 2 CON4 NO, COM, NC Relais de porte 1

    NO, COM, NC Relais de porte 2

    CON5 NO, COM, NC Relais de porte 3

    NO, COM, NC Relais de porte 4

    CON6 0V, D+, D Bus de donnes systme et autoprotection coffret (voir Connexion du bus de donnes du systme en page 18)

    T, C Contact dautoprotection

    CON7 1, 2, 3, 4 Entres de zone 14

    C Commun

    CON8 5, 6, 7, 8 Entres de zone 58

    C Commun

  • P/N 1070341 REV 2.0 ISS 22FEB11 17 / 56

    Conn. Bornes Description

    CON9 12V, 0V, D+, D

    Bus de donnes local pour connecter les RAS et DGP (voir Bus de donnes local ATS125x et raccordement la terre en page 18 pour plus de dtails)

    CON10 12V, 0V, D+, D

    Bus de donnes local pour connecter les RAS et DGP (voir Bus de donnes local ATS125x et raccordement la terre en page 18 pour plus de dtails)

    * Utiliser 2 batteries en srie. ** La sortie sirne extrieure est supervise. A rsistance de fin de

    ligne est de 1 k.

    Connexion au secteur

    Utilisez le bornier secteur pour connecter la centrale. Vous pouvez brancher un cble fixe ou un cordon d'alimentation flexible dans une prise secteur mise la terre. Si vous utilisez un cble fixe, insrez un circuit de protection ddi dans le rseau de distribution d'alimentation.

    AVERTISSEMENT: Risque dlectrocution. Pour viter tous dommages aux personnes ou lectrocution, supprimer toutes les sources d'alimentation avant linstallation ou le remplacement dquipement.

    Retrait/dpose de batterie Ce produit contient une (ou plusieurs) batterie au plomb, rechargeable, de type BS. Elle est sans maintenance, tanche, longue dure et ne doit pas tre normalement retire. Le retrait de la batterie peut affecter la configuration du produit ou dclencher une alarme, seul un installateur qualifi peut retirer la batterie.

    Pour retirer la batterie, suivre les tapes suivantes:

    1. Sassurer quil est possible douvrir le produit sans dclencher dautoprotection.

    2. Retirer lalimentation secteur, si ncessaire, et retirer le couvercle.

    3. Dconnecter la batterie, retirer les fils de connexion. Note, les connecteurs peuvent tre diffrents selon les modles de batterie.

    4. Retirer la batterie de son support.

    Pour un recyclage propre, entreposer toutes les batteries dans un local adquat. Voir les spcifications de votre produit ou contacter le support technique pour obtenir des informations sur le remplacement des batteries.

    Remarques importantes sur le montage Pour installer la centrale, insrez des vis ou des crous dans les quatre trous de fixation situs sur la base de lappareil.

    Assurez-vous que lunit est installe sur une surface verticale solide et plate afin dviter que la base ne flchisse ou ne se dforme lorsque vous resserrez les vis ou les crous.

    Laissez un espace de 50 mm entre les coffrets des appareils installs cte cte et de 25 mm entre le coffret et le mur latral.

    Nutilisez ces units que dans un environnement propre et sans humidit.

    Mount the unit using screws or bolts through the four mounting holes in the base.

    Voyants lumineux

    Tableau 3: LEDs ATS125x

    LED Description

    RST Si ce voyant clignote, les donnes scrutes sont reues de la centrale ATS sur le bus de donnes du systme.

    Rx1 Si ce voyant clignote, le DGP 4 portes rpond la scrutation de la centrale ATS sur le bus de donnes du systme.

    Tx1 Si ce voyant clignote, les units distantes (lecteurs/interfaces) rpondent la scrutation.

    Rx Si ce voyant clignote, le DGP 4 portes scrute la ou les units distantes (lecteurs/interfaces) sur le bus de donnes local ATS125x. Le voyant Tx1 doit toujours tre activ.

    Tx Indique que le relais de dverrouillage est activ.

    L1L4 Indique que le relais de dverrouillage Unlock est actif.

    Recommandations gnrales dinstallation Les contrleurs ATS125x ont t conues, assembles et testes conformment aux normes en vigueur notamment en matire de scurit lectrique, et dimmunit aux interfrences lectromagntiques.

    Installes dans les rgles de lart, ces centrales vous donneront satisfaction de nombreuses annes.

    En plus de ces recommandations dinstallation, il est essentiel de respecter les normes en vigueur et de ne faire effectuer les raccordements au rseau lectrique et tlphonique que par du personnel qualifi.

    Sassurer de la prsence dune bonne terre proximit de la centrale.

    Ne pas mixer les cables secteur et basses tension.Utiliser des entres de cables spares.

    Si les entres de cables suprieures ou infrieures sont utilises pour passer des cables, utiliser des presses toupes adapts et conformes la classe de flammabilit HB minimum.

    Le raccordement du cable secteur 2P + Terre se fait par un cable rigide ou souple connect au bornier prvu cet effet. Bien penser attacher le cable par le rilsan fourni.

    - En cas de raccordement secteur permanent, fates installer un disjoncteur ddi dans le tableau lectrique.

    - Ne pas souder les extrmits du cable secteur qui doivent tre visses dans le bornier secteur.

    Eviter davoir des boucles de cable lintrieur du coffret et trop proche de la carte mre de la centrale aussi bien en dessous quau dessus. Faire un cablage propre en guidant proprement et en attachant les cables.

    La batterie utilise doit tre de matriaux conformes la classe HB minimum.

    Tout circuit command par le relais intgr de la centrale ou pilot par les sorties lectroniques de la centrale dot tre antiparasit.

    - Ne pas installer de relais de puissance dans le coffret centrale

  • 18 / 56 P/N 1070341 REV 2.0 ISS 22FEB11

    - Mettre une diode de roue libre en parallle sur la bobine des relais

    - Utiliser des relais de bonne qualit disolation bobine / contacts.

    La distance entre chaque coffret dot tre de 50 mm minimum (pour la ventilation).

    Utiliser uniquement dans des environnements sains et non humides.

    Cblage

    Recommandations sur les raccordements du bus de donnes du systme

    Le cavalier TERM est mis en place sur le premier et le dernier module du bus de donnes du systme. Dans une configuration de cblage en toile, ce cavalier n'est install que sur les modules situs aux deux extrmits de la plus longue branche du bus de donnes du systme.

    Figure 2 lgende

    Numro Description

    1. Cavalier GND (ne pas l'installer)

    2. Borne de terre pour connexion du blindage

    3. Centrale ATS4000

    4. Cavalier TERM install (premier module dun bus de donnes local)

    5. Type de cble de donnes recommand : WCAT 52 (2 paires torsades)

    6. RAS avec LCD ATS1110 (le commutateur TERM n'est pas rgl sur ON)

    7. Alimentation 12 V spare. Ncessaire si le RAS est situ plus de 100 m de la centrale ou du DGP le plus proche. Connectez le sur le du bus de donnes

    8. Cavalier TERM install (dernier module dun bus de donnes local)

    9. Tout DGP tel que l'ATS125x

    Note: La configuration du bus de donnes local (non affich) est identique. Le bus de donnes local est raccord au connecteur J22 du contrleur ATS125x.

    Voir Connexion du bus de donnes du systme , Bus de donnes local ATS125x et raccordement la terre .

    Mise la terre

    AVERTISSEMENT: Vous devez suivre les instructions de la procdure de mise la terre.

    Mise la terre dun coffret contenant plusieurs cartes

    Tous les modules constituant le systme peuvent tre connects la terre par des cosses. Vous devez vous assurer que ces cosses offrent une bonne continuit vers le coffret (attention la peinture).

    Le raccordement la terre de chaque lment du systme peut tre utilis pour raccorder lcran de chaque cble blind.

    Si un module est plac dans un coffret en plastique, il est inutile de connecter la borne de terre.

    Mise la terre de coffrets d'un mme btiment

    Les quipements d'un mme btiment seront systmatiquement raccords la terre. La terre doit tre teste par un lectricien qualifi.

    Cas de plusieurs btiments

    Si le cblage stend plusieurs btiments, faites appel plusieurs systmes de mise la terre. Utilisez dans ce cas les rptiteurs/isolateurs ATS1740 pour isoler le bus de donnes du systme. De cette faon, le systme sera protg contre les diffrences de potentiel existant sur la terre.

    Blindage des cbles Le blindage des cbles utiliss dans le systme doit tre raccord une seule terre commune du btiment et d'UN SEUL ct. Si le cble du bus de donnes blind passe par plusieurs modules en plastique, la continuit du blindage du cble devra tre assure sur toute sa longueur.

    Figure 3 lgende

    Numro Description

    1. Alimentation secteur avec terre locale

    2. Connecteur secteur

    3. Bus de donnes du systme

    4. Borne de terre

    5. Btiment 1

    6. Btiment 2

    7. Module dans un coffret mtallique

    8. Module dans un coffret en plastique

    9. Centrale ATS

    Connexion du bus de donnes du systme Voir Figure 7.

    Le bus de donnes du systme est utilis pour connecter les DGP (tels que l'ATS125x) et les stations d'armement la centrale ATS. Les modules distants peuvent tre loigns de 1.5 km (maximum) d'une centrale ATS.

    Chaque module distant est affect d'une adresse et est scrut squentiellement par la centrale ATS. Douze DGP 4 portes peuvent tre connects au bus de donnes du systme.

    Les stations darmement et les DGP doivent tre connects par un cble de donnes blind deux paires torsades depuis la connexion du bus de donnes du systme (WCAT 52 de prfrence).

    Mettez la terre le blindage du cble de donnes au niveau de la centrale ATS. Laissez-le dbranch l'autre extrmit.

    Les DGP 4 portes possdent leur propre bloc d'alimentation (ils n'ont pas besoin d'tre aliments par le bus de donnes). Seules les connexions D+, D- et 0 V sont requises entre la centrale ATS et un DGP 4 portes.

    Bus de donnes local ATS125x et raccordement la terre Voir Figure 5.

  • P/N 1070341 REV 2.0 ISS 22FEB11 19 / 56

    L'ATS125x permet de connecter 16 stations d'armement (RAS avec LCD, lecteurs de carte puce) au bus de donnes local (CON9/CON10).

    Le bus de donnes local ATS125x consiste en 2 boucles lectriquement indpendantes. Si une des boucles est en dfaut, lautre boucle continue de communiquer avec les dispositifs distants. Le raccordement des dispositifs sur lune ou lautre est sans importance, les deux boucles fonctionnent comme un seul bus de donnes.

    Raccordez les contacts de porte et les boutons de demande de sortie associs chaque porte aux entres de l'ATS125x.

    Une zone utilise indiquant la porte est ouverte trop longtemps (DOTL Door Open Too Long) ne peut pas tre raccorde.

    A chaque dispositif est assign une adresse et est scrut en squence sur chaque boucle de lATS125x. Les dispositifs distants peuvent tre installs nimporte o jusqu 1.5 km de lATS125x. Chaque boucle doit avoir une terminaison de bus aux deux extrmits. Tableau 4: ATS1190

    12V Rouge D+ Blanc

    0V Noir D Vert

    Connexion du contact de porte et du bouton de demande de sortie

    Figure 2 lgende

    Numro Description

    1. Contact de porte

    2. Bouton de demande de sortie (bouton poussoir)

    Connexion du verrou de porte

    Voir Figure 9.

    Configuration des commutateurs DIP Les commutateurs DIP 1 4 (adresse DGP) sont utiliss pour identifier ce DGP sur la centrale Advisor Master (affectation de l'adresse DGP). Un DGP 4 portes/4 ascenseurs peut tre configur comme cela est indiqu dans la figure (DGP 1 12).

    Les commutateurs DIP 5 6 sont utiliss pour la configuration des extensions de zones. Figure 6 lgende

    Numro Description

    1. 8 entres intgres (aucune extension)

    2. 8 entres intgres + 1xATS1202

    3. 8 entres intgres + 2xATS1202

    4. 8 entres intgres + 3xATS1202

    Les commutateurs DIP 7 8 ne sont pas utiliss.

    Zones, RASs et sorties

    Numrotation

    Tous les DGP, RAS, zones et sorties sont numrots en fonction d'une formule donne. Ceci est utilis lors de la

    dtermination de numros/demplacements physiques de DGP, de sorties, etc. au cours de la programmation.

    Tableau 5: Zones, RAS et sorties alloues par DGP

    DGP / centrale

    Zones / RAS / sorties

    DGP / centrale

    Zones / RASs / sorties

    Centrale 1-16 DGP 7 113-128

    DGP 1 17-32 DGP 8 129-144

    DGP 2 33-48 DGP 9 145-160

    DGP 3 49-64 DGP 10 161-176

    DGP 4 65-80 DGP 11 177-192

    DGP 5 81-96 DGP 12 193-208

    DGP 6 97-112

    Zones

    Un DGP 4 portes a un maximum de 16 zones disponibles (ou 32 zones, sil occupe 2 adresses). Ces zones suivent la numrotation de zones standard.

    Exemple : L'ATS125x 1 est le DGP1 et dispose de 16 zones, que la centrale ATS identifie en tant que zones 17 32.

    Si toutes les 32 zones sont utilises, ladresse du prochain DGP ne sera pas disponible.

    For exemple: DGP1: zones 17-48, le DGP2 nest pas disponible, DGP3: zones 49-64.

    Voir les tableaux en page 12 pour plus de dtails sur les de zones par dfaut et paramtres des relais de dverrouillage.

    Note: Le DGP 4 portes ATS125x na seulement que 8 zones sur la carte mre. Les autres 24 zones sont connectes sur les extensions de zones ATS1202.

    RASs

    Les lecteurs de carte, claviers (ATS110x, ATS115x), et ATS1170 sont scruts comme des RAS. Les RAS sont raccords sur le bus local de l ATS125x. Chaque RAS a un numro unique dans le systme en fonction de ladresse du DGP 4 portes et ladresse du RAS sur le bus local. Voir le Tableau 5 ci-dessus pour plus de dtails.

    Les 16 RAS peuvent tre raccords sur le bus de donnes local de lATS125x. Les RAS sont associes une porte spcifique de lATS125x en fonction de leur adresse, qui dtermine galement lemplacement du lecteur sur la porte.

    Tableau 6: Adresses RAS et fonction lecteur

    ENTREE ENTREE SORTIE SORTIE

    Porte 1 1 5 9 13

    Porte 2 2 6 10 14

    Porte 3 3 7 11 15

    Porte 4 4 8 12 16

    Sorties

    Le DGP 4 portes a une sortie dalimentation commute (sortie sirne extrieure). Il y a galement quatre relais, un pour chaque porte (K1K4). Un DGP 4 portes peut adresser 48 sorties si vous utilisez la macro logique.

  • 20 / 56 P/N 1070341 REV 2.0 ISS 22FEB11

    Les cartes de sortie sont utilises pour augmenter le nombre de sorties sur un DGP. Chaque carte de sortie augmente le nombre de sorties par multiple de huit. Les numros de zone et de sortie sont toujours identiques aux 16 premiers numros de zone du DGP auquel les cartes sont connectes.

    Modules de sortie ATS1810 : La carte 4 relais permet d'utiliser les numros 5 8 des sorties alloues l'adresse DGP. Par exemple, le DGP 1 utilise les relais de dverrouillage 17, 18, 19 et 20 pour ouvrir les portes. Les sorties 21 24 sont disponibles sur la carte relais.

    Note: cette carte ne peut pas tre utilise avec des cartes de sorties ATS1811/ATS1820.

    ATS1811 : La carte 8 relais permet d'utiliser les numros 5 48 des sorties alloues l'adresse DGP. Par exemple, le DGP 1 utilise les relais de dverrouillage 17, 18, 19 et 20 pour ouvrir les portes. Les sorties 21 63 sont disponibles sur les cartes relais.

    ATS1820 : La carte 16 collecteurs ouverts est identique la carte ATS1811.

    Le DGP 4 portes peut activer les sorties 33 63 uniquement en utilisant la macro logique.

    Si vous faites appel plus de deux cartes ATS1811 ou ATS1820, utilisez une alimentation spare.

    Paramtres de zone et de relais par dfaut de l'ATS125x

    Tableau 7: Paramtres ATS125x par dfaut

    Porte 1 Porte 2 Porte 3 Porte 4

    Contact de porte 1 3 5 7

    Zone de demande de sortie 2 4 6 8

    Zone DOTL 9 10 11 12

    Relais de porte K1 K2 K3 K4

    Les numros de zone de ce tableau concernent les numros de zone physique sur le PCB ATS125x.

    Les numros de zone systme correspondant ces fonctions pour chaque centrale ATS125x figurent dans le Tableau 5 en page 19.

    Numrotation des portes

    Les numros de porte sont dtermins par :

    l'adresse du RAS ou du lecteur connect au bus de donnes du systme ATS (portes 1 16),

    l'adresse du DGP 4 portes (17 64).

    Les portes 17 64 sont utilises pour les numros de porte et sont contrles par un DGP 4 portes (ATS125x). Ces portes assurent des fonctions de contrle d'accs avances (anti retour, par exemple).

    Tableau 8: Numros de porte et d'ascenseur par DGP

    Module adresse Numro de porte

    RAS 1 16 1 16 (ouvre-porte uniquement)

    1 2 3 4

    DGP1 17 18 19 20

    DGP2 21 22 23 24

    DGP3 25 26 27 28

    DGP4 29 30 31 32

    DGP5 33 34 35 36

    DGP6 37 38 39 40

    DGP7 41 42 43 44

    DGP8 45 46 47 48

    DGP9 49 50 51 52

    DGP10 53 54 55 56

    DGP11 57 58 59 60

    DGP12 61 62 63 64

    Procdure de mise en route Une fois linstallation termine, sassurer que lunit est adresse correctement laide des commutateurs DIP 1 4 (adresse 1 12 autorise).

    Vrifier si la mmoire RAM sur l ATS125x et la centrale Advisor Master sont les mmes.

    Lors de la mise en route initiale, les voyants prsents sur le DGP 4 portes doivent tre dfinis comme suit :

    Voyant RST: OFF.

    Voyants du bus de donnes du systme ATS :

    Rx1: Clignote si l'ATS125x reoit des instructions de scrutation de la centrale ATS.

    Tx1: Dsactiv si l'ATS125x n'est ni adress ni programm pour tre scrut par la centrale.

    Voyants du bus de donnes local du DGP 4 portes :

    Tx: Clignote lorsque l'ATS125x scrute des modules distants (lecteurs/interfaces) sur le bus de donnes local ; TX doit toujours tre activ.

    Rx: Clignote pour indiquer que les modules distants rpondent la scrutation.

    Programmation minimale La programmation minimale consiste uniquement dclarer le DGP et les RAS connects.

    1. Adresser les RAS (lecteurs ou claviers) connects sur le bus de donnes local du DGP 4 portes

    2. Dans le menu de programmation de la centrale Advisor Master (menu 19.4): DGP, scruter le DGP 4 portes et dfinir le type de DGP.

    Pour accder au menu de programmation

    L'accs au menu de programmation de porte s'effectue via le menu 28 de l'installateur Advisor Master, Aux modules distants . Lorsque vous faites appel au menu de programmation 4 portes, vous programmez le module ATS125x.

  • P/N 1070341 REV 2.0 ISS 22FEB11 21 / 56

    Si l'accs au menu Aux modules distants vous est refus, cela signifie qu'un ou plusieurs des critres matriels ou de programmation ci-dessus n'est pas satisfait.

    1. L'affichage indique :

    Module distant : 1-DGP, 2-RAS Module :

    Entrez le type de module distant programmer. Slectionnez 1 (DGP).

    2. Entrez le numro du module distant programmer. Le numro du DGP est identique l'adresse du DGP.

    Configuration DGP distant N DGP :

    3. L'affichage suivant apparat brivement :

    Connexion en cours ENTER = annuler

    4. Vous venez d'accder au menu Programmation ATS125x du module ATS125x slectionn. L'affichage prsente le menu de programmation 4 portes suivant :

    "#"Poursuivre "*"-Option de menu Reculer :

    Reportez-vous au Menus de programmation de l'ATS125x ci-dessous pour obtenir des informations sur les options disponibles et savoir comment les configurer.

    Menus de programmation de l'ATS125x

    Voir Figure 11. # Menu Description

    1. Options de DGP Options gnrales valides pour l'ensemble des portes du DGP 4 portes slectionn.

    2. Options de porte Options valides pour chaque porte ou ascenseur du module ATS125x.

    3. Initialiser base de donnes

    Autorise l'initialisation de la base de donnes de portes. Rinitialise toutes les donnes du DGP leurs valeurs par dfaut.

    4. Afficher carte Affiche les dtails de la dernire carte badge sur l'cran LCD.

    5. Groupes de portes

    Permet d'afficher les dtails de groupes de portes.

    6. Reserved

    7. Options du systme

    Permet d'activer les sorties ATS125x afin d'indiquer les paramtres par dfaut du systme sur le module ATS125x.

    8. Macro logique de programme

    Permet de gnrer les sorties et vnements internes par fonctions logiques l'aide des vnements ATS1250x.

    9. Numro de version

    Numro de version CPLD et de l'EPROM ATS125x.

    10. Vers modules locaux

    Permet d'accder aux modules distants sur le bus de donnes local.

    Note : Le FORMAT DE CARD ne peut tre configur que par le logiciel de paramtrage.

    Initialisation de la base de donnes

    Initialiser le DGP 4 portes au dmarrage initial. Ceci est raliser via menu option 3, Initialiser base de donnes du menu de programmation

    Attention: Toutes les options de programmation seront remises leur valeur d'usine par dfaut. Les paramtres usine sont indiqus dans le guide de programmation

    Scrutation RAS connects

    Aller dans le menu 1, Options DGP.

    Dfinissez ou slectionnez les options suivantes: 1. Enter les adresses des RAS scruter. 2. Enter les adresses des RAS LCD connects.

    Pour plus de dtails sur la programmation du DGP 4 portes ATS125x se rfrer au Guide de programmation ATS125x.

    Dpannage

    Voyants du bus de donnes systme Rx1 Le voyant jaune Rx1 clignote pour indiquer que des donnes

    de scrutation sont reu sur le bus de donnes systme de la centrale. Si le voyant ne clignote pas, le contrleur nest pas oprationnel ou le bus en dfaut.

    Vrifier que les DGP sont correctement aliments.

    Vrifier le cblage des DGP sur le bus de donnes.

    Tx1 Le voyant rouge Tx1 clignote pour indiquer que le DGP rpond la scrutation de la centrale. Si le voyant Rx1 clignote mais pas le voyant Tx1, le DGP nest pas programm pour tre scrut dans la centrale ou a une mauvaise adresse.

    Vrifier que le DGP est bien connect sur le bus de donnes et a une adresse correcte.

    Vrifier que le DGP est scrut. (Menu centrale 19.4.)

    Voyants du bus de donnes local du DGP 4 portes Tx Le voyant rouge Tx clignote quand lATS125x scrute des

    dispositifs distants (lecteurs/interfaces) sur le bus de donnes local. Le voyant Tx doit toujours tre actif.

    Rx Le voyant jaune Rx clignote pour indiquer que les dispositifs distants rpondent la scrutation.

    Si le voyant ne clignote pas, les RAS ne sont pas programms, non adresss correctement ou le bus en dfaut.

    Vrifier que les RAS sont correctement aliments.

    Vrifier le cblage des RAS sur le bus de donnes.

    Vrifier que les RAS (lecteurs /interfaces) sont scruts. (Menu ATS 125x 1.4, Scruter RAS )

    Vrifier que les RAS sont adresss correctement.

    Spcifications techniques ATS1251

    ATS1253 ATS1252 ATS1254

    Spcifications gnrales

    Rsistances de fin de ligne

    Valeurs par dfaut : 4.7 k, 2 %, 0.25 W(Autre : 10 k, 2 %, 0.25 W; 2.2 k, 2%,

    0.25 W)

    Coffret Voir Tableau 1 en page 16

  • 22 / 56 P/N 1070341 REV 2.0 ISS 22FEB11

    ATS1251 ATS1253

    ATS1252 ATS1254

    PCB 202 x 218 x 48 mm

    Couleur Beige

    Temprature dutilisation

    10 +55C

    Humidit 95% sans condensation

    Indice IP de protection IP30

    Donnes techniques dalimentation

    Alimentation secteur principale

    230V ~ 10%, 50Hz 10%, 129 VA max.

    Consommation 230V~ 560 mA max.

    Alimentation secondaire de la carte mre (J17)

    30 V~ nominal

    Spcifications des alimentations

    Tension de sortie auxiliaire

    13.8 0.2 V 27.6 0.2 V

    Courant disponible max 4.0 A max. @ 13.8 0.2 V

    1.6 A max @ 27.6 V + 1.1 A max @ 13.8 V

    Courant de sortie auxiliaire

    13.8 0.2 V, 2 A max. Note: Courant maximum et permanent pour alimenter les diffrents organes hors condition dalarme.

    Sortie batterie 13.8 0.2 V 27.6 0.2 V Type de batterie Sche, rechargeable

    Capacit de batterie ATS1251: 1 x 26 Ah

    ATS1253: 1 x 7.2 ou 1 x 18 Ah

    ATS1252: 2 x 26 Ah

    ATS1254: 2 x 7.2 Ah

    Consommation de la centrale

    100 mA 13.8 0.2 V

    Courant restant 3.9 A @ 13.8 V 1.6 A max @ 27.6 V +1 A max @ 13.8 V

    Notes

    Le courant restant correspond au courant disponible pouvant tre utilis pour: lalimentation auxiliaire (incluant lalimentation commute), la charge batterie, lalimentation ventouse et du bus local. Le courant maximal peut tre dlivr tant que le courant restant maximum et la valeur du fusible de chaque sortie est respect.

    Le courant ncessaire pour la batterie dpend de lagrment. Voir Courant auxiliaire et capacit batterie ci-dessous pour quel courant doit tre rserv la charge batterie. Noter que les courants disponibles pour lalimentation auxiliaire, lalimentation des ventouses et lalimentation du bus local sont limits par le courant de la batterie.

    Pour les modles 12 V 3900 mA peut tre fourni au maximum. Au del current value drives the power supply into current limit.

    Pour les modles 24 V 1600 mA peut tre fourni sous 27.6 V (ventouses et batterie) et 1000 mA peut tre fourni sous 13.8 V (alimentation auxiliaire, alimentation commute et bus local).

    Fusibles F1: Batterie 1 5 A, rapide 20x5

    F2: Sortie d'alimentation auxiliaire 1 A, rapide 20x5

    F3: Bus de donnes local 1 800 mA, rapide 20x5

    F4: Bus de donnes local 2 800 mA, rapide 20x5

    F5: Lock power 1 2 A, rapide 20x5

    F6: Lock power 2 2 A, rapide 20x5

    F7: Switched power 1A, rapide 20x5

    Secteur*: Fusible secteur 800 mA, lent 20x5

    * Le fusible secteur se trouve dans le bornier secteur.

    ATTENTION: Avant de retirer ce fusible, dconnectez le secteur ! Voir Connexion au secteur en page 17.

    Courant auxiliaire et capacit batterie

    Tableau 9: Courant auxiliaire et capacit batterie ATS1251 & ATS1253 (modle 12 V)

    Type de batterie:* 7.2Ah 18Ah 26Ah

    Homologation Dure de dcharge (h)

    Dure de charge (h)

    Courant auxiliaire max disponible (mA)

    EN 1&2 12 72 450 1300 1800

    EN 3&4 60 24 = 175 290

    NF & A2P - 2 36 30 = 330 500

    NF & A2P - 3 72 30 = 110 200

    VdS - B 30 24 110 450 700

    VdS - C 60 24 = 175 290

    * La capacit batterie dpend galement du type de coffret. Voir Tableau 1 en page 16.

    Tableau 10: Courant auxiliaire et capacit batterie ATS1252 & ATS1254 (modle 24V)

    Type de batterie:* 2 x 7.2Ah

    2 x 18Ah

    2 x 26Ah

    Homologation Dure de dcharge (h)

    Dure de charge (h)

    Courant auxiliaire max disponible (mA)

    EN 1&2 12 72 500 1400 1800

    EN 3&4 60 24 = 200 300

    NF & A2P - 2 36 30 100 400 600

    NF & A2P - 3 72 30 = 150 250

    VdS - B 30 24 120 500 730

    VdS - C 60 24 = 200 300

    * La capacit batterie dpend galement du type de coffret. Voir Tableau 1 en page 16.

    Tous les courants auxiliaires mentionns dans les tableaux ci-dessus sont calculs pour une alimentation axillaire 24 V. Pour le calcul avec une alimentation axillaire 12 V un facteur de correction de 1.6 doit tre pris en compte.

    Formule: Iaux @12V = Iaux @24V x 1.6

    Example 1:

    Pour tre conforme EN grade 1&2 avec 2 batteries de 18 Ah. Lapplication a une charge maximum de 800 mA @ 24 V pour les ventouses. Selon le Tableau 10 ci-dessus, le courant maximum de lalimentation auxiliaire disponible sera de 1400 mA @ 24V.

    Cela signifie que derrire les 800 mA des ventouses 24V:

    1400 800 = 600 mA sont disponibles pour les alimentations @ 24 V ou

    600 x 1.6 = 960 mA sont disponibles pour les alimentations @ 12 V ex. alimentation auxiliaire, bus local

  • P/N 1070341 REV 2.0 ISS 22FEB11 23 / 56

    Example 2:

    Pour tre conforme NF & A2P type 2 avec 2 batteries de 18 Ah. Lapplication a une charge maximum pour le bus local (12 V) de 200 mA. Selon le Tableau 10 en page 22, le courant maximum de lalimentation auxiliaire disponible est de 400 mA @ 24 V.

    Ces 200 mA @ 12V du le bus local rsulte de:

    200 / 1.6 = 125 mA @ 24 V 400 125 = 275 mA @ 24 V pour les alimentations

    auxiliaires (par ex. ventouse).

    Restrictions:

    Max 12 V Aux current: 1000 mA Max 24 V Aux current: 1600 mA

    Le courant maximum de lalimentation auxiliaire peut tre limit par:

    Dure de dcharge La capacit de charge batterie Fusible auxiliaire

    Toutes les caractristiques de la carte sont donnes sans quipement extrieur.

    Distance de cblage

    Tableau 11: Distance de cblage

    De Distance Type de cble

    Bus de donnes systme de la centrale ATS (J10)

    Bus de donnes systme ATS125x (CON6)

    1,5 km (longueur totale du bus de donnes sans rptiteur)

    WCAT 52 ou quivalent

    Bus de donnes local 1 (CON9)

    RAS 1,5 km (longueur totale du bus de donnes sans rptiteur)

    WCAT 52 ou quivalent

    Bus de donnes local 2 (CON10)

    RAS 1,5 km (longueur totale du bus de donnes sans rptiteur)

    WCAT 52 ou quivalent

    Caractristiques en sortie (borniers)

    Tableau 12: Caractristiques en sortie (borniers)

    Repre Borne Description Min Typ Max Unit

    CON1 , Connexion CA du transformateur secondaire

    20 120

    VACVA

    +, Connexion batterie modle 12 V (ATS1251, ATS1253)

    13.6 13.8 7.2

    14.025

    VDCAh

    Connexion batterie modle 24 V (ATS1252, ATS1254)

    27.4 27.6 2x7.2

    27.82x25

    VDCAh

    CON2 +, , +, Sortie dalimentation auxiliaire

    13.6 13.8 14.02

    VDCA

    S+, S Sortie sirne extrieure

    13.6 13.8 14.01

    VDCA

    Repre Borne Description Min Typ Max Unit

    CON3 +, , +, Sortie alimentation ventouse modle 12 V (ATS1251, ATS1253)

    13.6 13.8 14.02

    VDCA

    Sortie alimentation ventouse modle 24 V (ATS1252, ATS1254)

    27.4 27.6 27.82

    VDCA

    CON4, CON5

    C, NO or NC

    Relais de contacts de porte (chacun)

    30 2

    VACA

    CON9, CON10

    +12 V Alimentation du bus local

    13.6 13.8 14.02

    VDCA

    Notes

    La consommation maximum totale des sorties dalimentation auxiliaires (++/) et la sirne extrieure ne doivent pas dpasser 2 A.

    La consommation maximum totale ne doit pas dpasser 3 A, incluant le courant de charge batterie.

    Information rglementaire Fabriquant UTC Fire & Security Americas Corporation, Inc.

    1275 Red Fox Rd., Arden Hills, MN 55112-6943, USA

    Mandataire agr UE: UTC Fire & Security B.V. Kelvinstraat 7, 6003 DH Weert, Pays-Bas

    Certification

    Directives europennes

    UTC Fire & Security dclare, par la prsente, que cet quipement est conforme aux principales exigences et dispositions de la Directive 1999/5/EC.

    2002/96/EC (WEEE) : Les produits marqus de ce symbole peuvent pas tre limins comme dchets municipaux non tris dans lUnion europenne. Pour le recyclage, retourner ce produit votre fournisseur au moment de lachat dun nouvel quipement quivalent,ou des points de collecte dsigns. Pour plus dinformations, voir: www.recyclethis.info.

    Contact www.utcfireandsecurity.com, www.interlogix.com

    IT: Istruzioni dinstallazione

    Nota importante Questo manuale fornisce informazioni per i seguenti concentratori 4-varchi (DGP): ATS1251, ATS1252, ATS1253 e ATS1254. Quando ci si riferisce ad un DGP 4-varchi, questo da considerarsi valido per ogni variante dell ATS125x, tranne quanto specificato diversamente.

    Tabella 1: Lista delle varianti del DGP 4-varchi

    Variante Alimen-tazione ausiliaria

    Alimen-tazione serratura

    Contenitore Dimensioni

    ATS1251 12 V 12 V ATS1642 grande

    480x464x160 mm

    ATS1252 12 V 24 V* ATS1642 grande

    480x464x160 mm

  • 24 / 56 P/N 1070341 REV 2.0 ISS 22FEB11

    Variante Alimen-tazione ausiliaria

    Alimen-tazione serratura

    Contenitore Dimensioni

    ATS1253 12 V 12 V ATS1640 piccolo

    445x315x90 mm

    ATS1254 12 V 24 V* ATS1640 piccolo

    445x315x90 mm

    * In caso della variante a 24 V utilizzare sempre 2 batterie in serie.

    ATS125x 4-varchi DGP informazioni generali La figura 1 illustra la disposizione del DGP 4-varchi.

    Legenda Figura 1

    Oggetto Descrizione

    1. Interruttori DIPSWITCH (vedere Impostazioni interruttori DIPSWITCH a pagina 27)

    2. RAM o IUM (opzionale)

    3. EPROM (inserita di fabbrica)

    4. Ponticello KILL: Impostazione di fabbrica ATS125x quanto chiuso

    5. Batteria fusibile F1

    6. Alimentazione ausiliaria fusibile F2

    7. Bus dati 1 fusibile F3

    8. Bus dati 2 fusibile F4

    9. Alimentazione serratura 1 fusibile F5

    10. Alimentazione serratura 2 fusibile F6

    11. Sirena / Commutata F7

    12. LEDs L1-L4

    13. TERM 1: Usare questo cavallotto per terminare il bus dati di sistema

    14. TERM 2: Usare questo cavallotto per terminare il bus dati locale, connessione 1 sul terminale CON9

    15. TERM 3: Usare questo cavallotto per terminare il bus dati locale, connessione 2 sul terminale CON10

    16. CON14 Connettore espansione ingressi

    17. CON15 Connettore espansione uscite

    18. Terminale rete 220

    Connessioni

    Tabella 2: Connessioni ATS125x

    Conn. Cavo Descrizione

    CON1 , Connessione alimentazione Terra di sistema (vedere Collegamento a

    terra a pagina 26)

    +, Batterie 2 x 12 V , 7.2 Ah (versione 24 V)*Batteria 1 x 12 V , 7.2 Ah (versione 12 V)

    CON2 +, Alimentazione ausiliaria +, Alimentazione ausiliaria S+, S ** Uscita sirena esterna CON3 +, Alimentazione serratura 1 +, Alimentazione serratura 2 CON4 NO, COM, NC Rel varco 1

    NO, COM, NC Rel varco 2

    Conn. Cavo Descrizione

    CON5 NO, COM, NC Rel varco 3

    NO, COM, NC Rel varco 4

    CON6 0V, D+, D Bus dati di sistema e ingresso manomissione centrale (vedere Connessione del bus dati del sistema ATS a pagina 26 per dettagli)

    T, C Ingresso manomissione

    CON7 1, 2, 3, 4 Zone 14 ingressi

    C Comune

    CON8 5, 6, 7, 8 Zone 58 ingressi

    C Comune

    CON9 12V, 0V, D+, D

    Bus dati locale per la connessione di RAS e DGP (vedere Connessione del bus dati locale dellATS125x a pagina 26 per dettagli)

    CON10 12V, 0V, D+, D

    Bus dati locale per la connessione di RAS e DGP (vedere Connessione del bus dati locale dellATS125x a pagina 26 per dettagli)

    * Per modelli a 24 VDC, utilizzare sempre due batterie in serie.

    ** Luscita sirena esterna un uscita supervisionata. Tipicamente la resistenza di fine linea 1 K.

    Connessione alimentazione di rete

    Per la connessione allalimentazione di rete usare la morsettiera predisposta e connettere il cavo ad unutenza di rete con collegamento di terra. Nel caso di collegamento permanente alla rete elettrica, inserire nel circuito di alimentazione di rete un interruttore bipolare dedicato facilmente accessibile.

    ATTENZIONE: Scollegare il DGP dalla rete elettrica prima di aprire il contenitore! Estraendo la spina dalla presa di rete a muro, o aprendo il circuito tramite linterruttore bipolare.

    Sostituzione batterie Questo prodotto contiene una (o pi) batteria tipo BS al piombo ricaricabile, sigillata. Questa una batteria senza manutenzione, a prova di perdita e di lunga durata che non dovrebbe essere rimossa in normali circostanze. Rimuovere la batteria potrebbe avere effetti sulle impostazioni del prodotto o generare un allarme, solo installatori qualificati dovrebbero rimuovere la batteria.

    Per rimuovere la batteria procedure nel seguente modo:

    1. Assicurarsi che le impostazioni del prodotto permettano di poter aprire il coperchio senza attivare allarmi di manomissione.

    2. Togliere lalimentazione di rete, se necessario e rimuovere il coperchio.

    3. Disconnettere la batteria, togliendo i cavi del prodotto dai connettori. Nota, in funzione del modello di batteria, i connettori possono essere posizionati differentemente.

    4. Rimuovere la batteria del contenitore.

    Per il corretto smaltimento, sistemare tutte le batterie come richiesto dalle locali ordinanze o norme. Vedere le specifiche

  • P/N 1070341 REV 2.0 ISS 22FEB11 25 / 56

    per il vostro prodotto o contattare il supporto tecnico per informazioni sulla sostituzione batterie.

    Note importanti sul montaggio Fissare lunit inserendo le viti o i bulloni nei quattro fori di montaggio presenti sulla base.

    Aver cura di montare lunit su una superficie verticale piana e solida, in modo che la base non fletta o si deformi durante il serraggio delle viti/bulloni di fissaggio.

    Spazio minimo tra i contenitori degli apparati: 50 mm (tra le aperture di ventilazione degli apparati). Spazio minimo tra i contenitori e la parete laterale: 25 mm.

    Usare le unit esclusivamente in ambiente pulito e privo di umidit.

    LED

    Tabella 3: ATS125x LEDs

    LED Descrizione

    RST OFF: il microprocessore sta funzionando regolarmente.

    ON: il sistema in stato di reset.

    Rx1 Il LED lampeggiante indica che il concentratore 4 varchi riceve dati dalla centrale ATS sul bus dati di sistema.

    Tx1 Il LED lampeggiante indica che il concentratore 4 varchi (DGP) sta rispondendo al polling eseguito dalla centrale ATS sul bus dati di sistema.

    Rx Il LED lampeggiante indica che le unit remote (lettori/interfacce) presenti sul bus dati locale, stanno rispondendo al polling.

    Tx Il LED lampeggiante indica che il concentratore 4 varchi (DGP) sta eseguendo il polling della/e unit remote (lettori/interfacce) sul suo bus dati locale. Il LED Tx dovrebbe essere sempre attivo.

    L1L4 Indica che il rel di sblocco attivo.

    Linee guida generali per linstallazione I concentratori (DGP) ATS125x sono stati progettati, assemblati e sottoposti a test per soddisfare gli standard correnti relativi alla sicurezza elettrica, alla emissione e alla immunit alle interferenze elettriche ed elettromagnetiche ambientali. Il rispetto delle seguenti indicazioni contribuir a garantire un efficace e duraturo funzionamento dei concentratori per diversi anni.

    Oltre alle presenti indicazioni essenziale rispettare, durante linstallazione concentratori (DGP) ATS125x, tutte le normative vigenti nei paesi in cui linstallazione viene effettuata.

    Solo un elettricista qualificato o un tecnico specializzato ed opportunamente addestrato pu collegare questo sistema alla rete elettrica o alla rete telefonica.

    Assicurarsi che sia disponibile una messa a terra adeguata per il sistema di allarme.

    Mantenere una separazione appropriata tra i cavi di bassa tensione e i cavi di alimentazione di rete. Utilizzare punti di ingresso del cavo separati nell'armadio del dispositivo di controllo.

    Se vengono usati i fori nella parte superiore o inferiore dellarmadio metallico per il passaggio dei cavi, usare

    sempre tubi di raccordo, scatole di giunzione ed accessori appropriati. Usare materiale resistente al fuoco (Classe HB o superiore).

    Per il collegamento alla rete elettrica, collegare i cavi ai morsetti di alimentazione di rete predisposti o tramite una connessione fissa o da una presa di corrente con collegamento di terra. Usare sempre delle fascette per fissare i cavi provenienti dalla rete elettrica agli appositi punti di fissaggio, vicino al morsetto di alimentazione.

    - Nel caso di collegamento perma