8
SECURITY IMPROVEMENTS AT THERESA MAHLER EARLY EDUCATION SCHOOL 990 CHURCH STREET SAN FRANCISCO, CA 94114 SFUSD Project No. 12064 CCTV SURVEILLANCE SYSTEM INSTALLATION SCOPE OF WORK FOR THIS PROJECT IS NEW CAMERAS AND SECURITY MONITORING SYSTEM, ALONG WITH NEW VIDEO RECORDING NVR (1) AND ALL CABLING, CONDUIT, WIREWAY , POWER SUPPLIES AND NECESSARY INFRASTRUCTURE TO PROVIDE A WORKING AND OPERABLE SYSTEM PER PLANS AND SPECIFICATIONS. NEW AIPHONE VIDEO ENTRY INTERCOM STATIONS , CONSISTING OF DOOR STATIONS, MASTER STATIONS AND CONTROLLER, POWER SUPPLIES AND CABLING, CONDUIT, BOXES, ETC. SFUSD HAS SPECIFIC CCTV REQUIREMENTS, SEE SPECIFICATIONS FOR VENDORS, CAMERAS, DISPLAY SCREENS, CABLING, ETC. (NOTE THAT ALL NEW HOLES, PENETRATIONS, DRILLING, ANCHORS, ETC. WILL NEED TO BE INSPECTED BY DISTRICT HAZ MAT CONSULTANT. ALL DISTRICT PROCEDURES MUST BE FOLLOWED FOR ALL WALL AND FLOOR PENETRATIONS AND ATTACHMENTS.) PROJECT SITE LOCATION THERESA S MAHLER EES 990 CHURCH STREET SAN FRANCISCO, CA 94114 TY-01 TITLE PAGE, SCOPE AND DRAWING INDEX SITE NO. SCALE DATE CHECKED BY S.F.U.S.D. PROJECT NO. SHEETS DRAFTER OF XXXX 05/31/18 JSM - 12064 CONSTRUCTION DESIGN & FACILITIES 135 Van Ness Avenue San Francisco, California 94102 Tel (415) 355-6979 Fax (415) 355-6988 Architect Engineer School Name and Address Project Name Date No. Revisions SHEET NO. DRAWING TITLE Approvals AS NOTED SFUSD SAN FRANCISCO PUBLIC SCHOOLS Consultant Name and Address 05/15/2018 - BID ISSUE G U T T M A N N B L A E V O E T C O N S U L T I N G E N G I N E E R S E P F THERESA MAHLER EARLY EDUCATION SCHOOL 990 CHURCH STREET SAN FRANCISCO, CA 94114 SFUSD PROJ. #12064 SECURITY IMPROVEMENTS TY- 01 TITLE PAGE, SCOPE AND DRAWING INDEX TY- 02 WIRE LEGEND , SYMBOLS AND ABBREVIATIONS TY- 03 GENERAL NOTES AND PROJECT NOTES TY- 2.1 CCTV SURVEILLANCE AND VIDEO ENTRY INTERCOM PARTIAL FLOOR PLAN - MISSION CAMPUS TY- 5.1 SECURITY SYSTEM BLOCK RISER DIAGRAM & CAMERA MATRIX SCHEDULE TY - 7.1 SECURITY DETAILS TY - 7.2 SECURITY DETAILS TY - 7.3 SECURITY DETAILS

AT EARLY EDUCATION SCHOOL 990 CHURCH … · conduit fill is the sole responsibility of the ... CAT 6. CABLE FOR SECURITY CAMERA VIDEO TRANSMISSION RJ 45 TERMINATED/CERTIFIED PER …

Embed Size (px)

Citation preview

Page 1: AT EARLY EDUCATION SCHOOL 990 CHURCH … · conduit fill is the sole responsibility of the ... CAT 6. CABLE FOR SECURITY CAMERA VIDEO TRANSMISSION RJ 45 TERMINATED/CERTIFIED PER …

SECURITY IMPROVEMENTS

AT

THERESA MAHLEREARLY EDUCATION SCHOOL

990 CHURCH STREETSAN FRANCISCO, CA 94114

SFUSD Project No. 12064

CCTV SURVEILLANCE SYSTEM INSTALLATION

SCOPE OF WORK FOR THIS PROJECT IS NEW CAMERAS AND SECURITY MONITORING SYSTEM, ALONG WITH NEW VIDEO RECORDING NVR (1) AND ALL CABLING, CONDUIT, WIREWAY ,

POWER SUPPLIES AND NECESSARY INFRASTRUCTURE TO PROVIDE A WORKING AND OPERABLE SYSTEM PER PLANS AND SPECIFICATIONS.

NEW AIPHONE VIDEO ENTRY INTERCOM STATIONS , CONSISTING OF DOOR STATIONS, MASTER STATIONS AND CONTROLLER, POWER SUPPLIES AND CABLING, CONDUIT, BOXES, ETC.

SFUSD HAS SPECIFIC CCTV REQUIREMENTS, SEE SPECIFICATIONS FOR VENDORS, CAMERAS, DISPLAY SCREENS, CABLING, ETC.

(NOTE THAT ALL NEW HOLES, PENETRATIONS, DRILLING, ANCHORS, ETC. WILL NEED TO BE INSPECTED BY DISTRICT HAZ MAT CONSULTANT. ALL DISTRICT PROCEDURES MUST BE

FOLLOWED FOR ALL WALL AND FLOOR PENETRATIONS AND ATTACHMENTS.)

PROJECT SITE LOCATION

THERESA S MAHLER EES

990 CHURCH STREET

SAN FRANCISCO, CA 94114

TY-01

TITLE PAGE, SCOPE AND

DRAWING INDEX

SITE NO.

SCALE

DATECHECKED BY

S.F.U.S.D. PROJECT NO.

SHEETS

DRAFTER

OF

XXXX05/31/18 JSM -

12064

CONSTRUCTION

DESIGN &

FACILITIES

135 Van Ness Avenue

San Francisco, California 94102

Tel (415) 355-6979

Fax (415) 355-6988

Architect Engineer

School Name and Address

Project Name

Date No. Revisions

SHEET NO.

DRAWING TITLE

Approvals

AS NOTED

SFUSD SAN FRANCISCOPUBLIC SCHOOLS

Consultant Name and Address

05/15/2018 - BID ISSUE

G U T T M A N N B L A E V O E T

C O N S U L T I N G E N G I N E E R S

E

P F

THERESA MAHLER

EARLY EDUCATION SCHOOL

990 CHURCH STREET

SAN FRANCISCO, CA 94114

SFUSD PROJ. #12064

SECURITY

IMPROVEMENTS

TY- 01 TITLE PAGE, SCOPE AND DRAWING INDEX

TY- 02 WIRE LEGEND , SYMBOLS AND ABBREVIATIONS

TY- 03 GENERAL NOTES AND PROJECT NOTES

TY- 2.1 CCTV SURVEILLANCE AND VIDEO ENTRY INTERCOM PARTIAL FLOOR PLAN - MISSION CAMPUS

TY- 5.1 SECURITY SYSTEM BLOCK RISER DIAGRAM & CAMERA MATRIX SCHEDULE

TY - 7.1 SECURITY DETAILS

TY - 7.2 SECURITY DETAILS

TY - 7.3 SECURITY DETAILS

AutoCAD SHX Text
DRAWING INDEX
AutoCAD SHX Text
VICINITY PLAN
AutoCAD SHX Text
PROJECT SCOPE
AutoCAD SHX Text
2351 Powell Street
AutoCAD SHX Text
&
AutoCAD SHX Text
415 655 4000 415 655 4001
AutoCAD SHX Text
San Francisco, CA. 94133-1449
AutoCAD SHX Text
Page 2: AT EARLY EDUCATION SCHOOL 990 CHURCH … · conduit fill is the sole responsibility of the ... CAT 6. CABLE FOR SECURITY CAMERA VIDEO TRANSMISSION RJ 45 TERMINATED/CERTIFIED PER …

RATED WALL

ALL PENETRATIONS THROUGH RATED

WALLS MUST BE FIRE SEALED AND CAULKED

A AMPERES

ACAMS ACCESS CONTROL AND ALARM MONITORING SYSTEM

AFF ABOVE FINISHED FLOOR

AWG AMERICAN WIRE GAUGE

BAS BUILDING AUTOMATION SYSTEM

BDF BUILDING DISTRIBUTION FACILITY

C CONDUIT

CAT3 CATEGORY 3 TWISTED PAIR UTP CABLE

CAT5E CATEGORY 5E TWISTED PAIR UTP CABLE

CAT6 CATEGORY 6 TWISTED PAIR UTP CABLE

CATV COMMUNITY ANTENNA TELEVISION

CEC CCTV EQUIPMENT CABINET

DIV DIVISION

(E) EXISTING

EC ELECTRICAL CONTRACTOR

EMS ELECTRIC MANAGEMENT SYSTEM

EMT ELECTRICAL METALLIC TUBING

(ER) EXISTING REPLACE

(F) FUTURE

FACP FIRE ALARM CONTROL PANEL

FATC FIRE ALARM TERMINAL CABINET

FO FIBER OPTIC

REX REQUEST TO EXIT

SAD SEE ARCHITECTURAL DRAWINGS

SEC SECURITY EQUIPMENT CABINET

SM SINGLEMODE OPTICAL FIBER

SCTP SCREENED TWISTED PAIR

STR STRAND(S) OF FIBER

STP SHEILDED TWISTED PAIR

TBB TELECOM BONDING BACKBONE

TBC TELECOM BONDING CONDUCTOR

TGB TELECOM GROUNDING BUSBAR

TMGB TELECOM MAIN GROUNDING BUSBAR

TYP TYPICAL

UON UNLESS OTHERWISE NOTED

UPS UNINTERRUPTIBLE POWER SUPPLY

UTP UNSHEILDED TWISTED PAIR

V VOLTS

WP WEATHERPROOF

NOT ALL ABBREV. MAY BE

USED ON THIS PROJECT

GC GENERAL CONTRACTOR

IDF INTERMEDIATE DISTRIBUTION

FACILITY

JB JUNCTION BOX

LCP LIGHTING CONTROL PANEL

MDF MAIN DISTRIBUTION FACILITY

MH MAINTENANCE HOLE

MM MULTIMODE FIBER OPTIC CABLE

MPOE MINIMUM POINT OF ENTRY

MT EMPTY

N or (N) NEW

NC NORMALLY CLOSED

NO NORMALLY CLOSED

NTS NOT TO SCALE

OC ON CENTER

OSP OUTSIDE PLANT

PB PULL BOX

PNL PANEL

PR PAIR (OF COPPER CONDUCTORS)

PVC POLYVINYL CHLORIDE

TY-02

WIRE LEGEND , SYMBOLS

AND ABBREVIATIONS

SYMBOL DESPCRIPTION

SECURITY TERMINAL OR SYSTEMS CABINET

BOX

N/A

RING

N/A

MT. HT CONDUIT

3/4" MIN

NOTES

SEE KEYED NOTES, GENERAL NOTES AND

SPECIFICATIONS FOR SIZE AND TYPE

STC RSTC

SECURITY CAMERA - DOME TYPE FIXED FOCAL LENGTH

WP

SECURITY CAMERA - DOME TYPE FIXED FOCAL LENGTH

WEATHERPROOF

SECURITY AND ACCESS CONTROL SYMBOL LEGEND

WP

SECURITY CAMERA - DOME TYPE PTZ WEATHERPROOF

IC

M

IC

CA

SECURITY DOOR ENTRY SYSTEM CAMERA AND CALL STATION

SECURITY DOOR ENTRY VIDEO MONITOR STATION

MFR.

MFR.

MFR.

+102"

+120"

+120"

+72" TO

TOP

NVR

VSW

JOY

M24

M32

NETWORK VIDEO RECORDER, RACK MOUNTED

VIDEO SWITCHER, RACK MOUNTED

CAMERA POWER SUPPLY, WALL MOUNTED

DESK MOUNTED JOY STICK CONTROLLER AT PRINCIPALS OFFICE

24" VIDEO DISPLAY DESK MOUNTED AT PRINCIPALS OFFICE WITH WALL

MOUNT BRACKET/ARM

32" VIDEO WALL MOUNTED MONITOR FOR PUBLIC VIEW OF CAMERAS

WITH WALL MOUNT BRACKET/ARM

MFR.

MFR.

MFR.

N/A

N/A

N/A

N/A

N/A

+48 - +54"

RACK

RACK

+72" MAX

N/A

N/A

+96 MAX

+48 - +54"

N/A

N/A

N/A

N/A

N/A

40% FILL

3/4" MIN

40% FILL

3/4" MIN

40% FILL

3/4" MIN

40% FILL

3/4" MIN

40% FILL

3/4" MIN

40% FILL

PWR

SEC

DOOR POWER SUPPLY, WALL MOUNTED

PWR

DOOR

AIPHONE POWER SUPPLY, WALL MOUNTED

PWR

AIPH

PATCH PANEL FOR CAT 6 CABLES FROM CAMERAS

PP

TVM

TVM

XXCAMERA ID TAG CALLOUT

D

P1

VIDEO SYSTEM WIRE LEGEND INDEX

P2

T25

T100

V1

V2

MODEL

CONDUIT WIRE FILL CHART

SEE SPECS

SEE SPECS

SEE SPECS

SEE SPECS

SEE SPECS

SEE SPECS

SEE SPECS

SEE SPECS

SEE SPECS

SEE SPECS

SEE SPECS

SEE SPECS

SEE SPECS

SEE SPECS

SEE SPECS

SITE NO.

SCALE

DATE

CHECKED BY

S.F.U.S.D. PROJECT NO.

SHEETS

DRAFTER

OF

XXXX05/31/18 JSM -

12064

CONSTRUCTION

DESIGN &

FACILITIES

135 Van Ness Avenue

San Francisco, California 94102

Tel (415) 355-6979

Fax (415) 355-6988

Architect Engineer

School Name and Address

Project Name

Date No. Revisions

SHEET NO.

DRAWING TITLE

Approvals

AS NOTED

SFUSD SAN FRANCISCOPUBLIC SCHOOLS

Consultant Name and Address

05/15/2018 - BID ISSUE

G U T T M A N N B L A E V O E T

C O N S U L T I N G E N G I N E E R S

E

P F

THERESA MAHLER

EARLY EDUCATION SCHOOL

990 CHURCH STREET

SAN FRANCISCO, CA 94114

SFUSD PROJ. #12064

SECURITY

IMPROVEMENTS

Technical Reference

Conduit Capacity Chart

Conduit Size 1/2

I.D. Inches

Permissible Area*

Cable O.D

Inch

.100

.125

.150

.175

.200

.225

.250

.275

.300

.325

.350

.375

.400

.425

.450

.475

.500

.525

.550

.575

.600

.625

.650

.675

.700

.725

.750

.775

.800

.825

.850

.875

.900

.925

.950

.975

1.00

1.025

1.05

1.075

1.100

1.125

1.150

1.175

1.20

1.225

1.250

1.275

1.300

1.325

1.350

1.375

1.400

1.425

1.450

1.475

1.500

Cable Area

sq. Inch

.00785

.01227

.01767

.02405

.03142

.03976

.04909

.0594

.07069

.08296

.09621

.011045

.012566

.14186

.15904

.17721

.19635

.21648

.23758

.25967

.28274

.3068

.33183

.35785

.38484

.41282

.44179

.47173

.50265

.53456

.56745

.60132

.63617

.67201

.70882

.74662

.7854

0.825

0.866

0.908

0.950

0.994

1.039

1.084

1.131

1.179

1.227

1.277

1.327

1.379

1.431

1.485

1.539

1.595

1.651

1.709

1.767

15

10

7

5

4

3

2

1

1

1

1

1

1

1

1

1

1

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

27

17

12

9

6

5

4

3

3

2

1

1

1

1

1

1

1

1

1

1

1

1

1

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

44

28

19

14

11

8

7

6

5

4

3

3

2

2

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

WEST PENN WIRE

76

48

34

25

19

15

12

10

8

7

6

5

4

4

3

3

3

2

2

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

103

66

46

34

26

20

16

13

11

10

8

7

6

5

5

4

4

3

3

3

3

2

2

1

1

1

1

1

1

1

1

1

1

1

1

1

1

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

171

109

76

56

42

33

27

22

19

16

14

12

10

9

8

7

7

6

5

5

4

4

4

3

3

3

3

3

2

2

2

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

0

0

0

0

0

0

0

0

298

191

132

97

74

59

47

39

33

28

24

21

18

16

14

13

12

11

10

9

8

7

7

6

6

5

5

5

4

4

4

4

3

3

3

3

3

3

2

2

2

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

450

288

200

147

112

89

72

59

50

42

36

32

28

25

22

20

18

16

15

13

12

11

10

10

9

8

8

7

7

6

6

6

5

5

5

4

4

4

3

3

3

2

2

2

2

2

2

2

2

2

2

1

1

1

1

1

1

588

376

261

192

147

116

94

77

65

55

48

42

36

32

29

26

23

21

19

17

16

15

14

13

12

11

10

9

9

8

8

7

7

7

6

6

6

6

4

4

4

3

3

3

3

3

3

3

3

3

2

2

2

2

2

2

2

751

481

334

245

188

148

120

99

83

71

61

53

47

41

37

33

30

27

25

22

21

19

17

16

15

14

13

12

11

11

10

10

9

9

8

8

7

7

5

5

5

5

4

4

4

4

4

3

3

3

3

3

3

3

3

2

2

.622

0.12

3/4

.824

0.21

1

1.049

0.34

1 1/4

1.380

0.60

1 1/2

1.610

0.82

2

2.067

1.34

2 1/2

2.469

1.92

3

3.068

2.95

3 1/2

3.548

3.96

4

4.026

5.09

EXAMPLES:

Example A.

Sample Cable:

227- .260” O.D.

Example B.

Three different Cables:

227 - .260” sqd. = .0676

D434 - .411” sqd. = .1689

6350 - .275” sqd. = .0756

+

.3169

x .7854

.2489

CABLE WITH CONFIDENCE

On the Permissible Area-

equal to or greater. The

closest area is .034 Use a

1” Conduit

Go down the Cable O.D.

inch col-umn. Find the

number equal to or greater

than the cable O.D. Go

across to find the number

of cables in the appropriate

conduit size.

.269”- Closest .275”

13 in a 11/2” Conduit.

Important Note: This

conduit capacity chart is to

be used as a general

guideline. Because local

codes can vary from the

NEC. West Penn Wire

cannot be held responsible

for this information as it

pertains to your

installation. Proper

conduit fill is the sole

responsibility of the

installer and it is your

responsibility to see that

your installation will pass

local codes.

PTCH

AutoCAD SHX Text
ABBREVIATIONS
AutoCAD SHX Text
360
AutoCAD SHX Text
02
AutoCAD SHX Text
1 PAIR
AutoCAD SHX Text
#18/2 TP
AutoCAD SHX Text
N/A
AutoCAD SHX Text
TWISTED PR
AutoCAD SHX Text
POWER CABLE FOR CAMERA POWER 18/2 , FOR FIXED CAMERA , WEST PENN #224 OR EQUAL
AutoCAD SHX Text
ITEM
AutoCAD SHX Text
NO.
AutoCAD SHX Text
INDICATOR
AutoCAD SHX Text
NO. OF
AutoCAD SHX Text
CONDUCTORS
AutoCAD SHX Text
COLOR
AutoCAD SHX Text
SIZE AWG.
AutoCAD SHX Text
WIRE TYPE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
WIRE LEGEND INDEX
AutoCAD SHX Text
01
AutoCAD SHX Text
4 PAIR
AutoCAD SHX Text
#24 TSP
AutoCAD SHX Text
N/A
AutoCAD SHX Text
CAT 6
AutoCAD SHX Text
CABLE FOR SECURITY CAMERA VIDEO TRANSMISSION RJ 45 TERMINATED/CERTIFIED PER EIA.TIA STANDARDS
AutoCAD SHX Text
03
AutoCAD SHX Text
1 PAIR
AutoCAD SHX Text
#12 TP
AutoCAD SHX Text
N/A
AutoCAD SHX Text
TWISTED PR
AutoCAD SHX Text
POWER CABLE FOR CAMERA POWER 12/2 , FOR DOOR STRIKE, WEST PENN #227 OR EQUAL
AutoCAD SHX Text
04
AutoCAD SHX Text
25 PAIR
AutoCAD SHX Text
#24 TP
AutoCAD SHX Text
N/A
AutoCAD SHX Text
TWISTED PR
AutoCAD SHX Text
MULTI PAIR (25 PAIR) CAT-5e CABLE FOR TRUNK VIDEO TRANSMISSION BETWEEN IDF AND MDF
AutoCAD SHX Text
06
AutoCAD SHX Text
100 PAIR
AutoCAD SHX Text
#18 TP
AutoCAD SHX Text
N/A
AutoCAD SHX Text
TWISTED PR
AutoCAD SHX Text
MULTI PAIR (100) CAT-3 CABLE FOR TRUNK VOICE TRANSMISSION BETWEEN IDF AND MDF
AutoCAD SHX Text
07
AutoCAD SHX Text
1 PAIR
AutoCAD SHX Text
#18/2 TP
AutoCAD SHX Text
N/A
AutoCAD SHX Text
TWISTED PR
AutoCAD SHX Text
VIDEO INTERCOM CABLE BETWEEN MASTER STATION AND DOOR STATION. WEST PENN #224 OR EQUAL
AutoCAD SHX Text
08
AutoCAD SHX Text
1 CABLE
AutoCAD SHX Text
RG6 COAX
AutoCAD SHX Text
N/A
AutoCAD SHX Text
COAXIAL
AutoCAD SHX Text
BASEBAND VIDEO CABLE FOR MONITOR DISPLAY, RG-6 TYPE 95% COPPER BRAID
AutoCAD SHX Text
2351 Powell Street
AutoCAD SHX Text
&
AutoCAD SHX Text
415 655 4000 415 655 4001
AutoCAD SHX Text
San Francisco, CA. 94133-1449
AutoCAD SHX Text
AutoCAD SHX Text
09
AutoCAD SHX Text
4 PAIR
AutoCAD SHX Text
#24 TSP
AutoCAD SHX Text
N/A
AutoCAD SHX Text
CAT 6
AutoCAD SHX Text
CABLE FOR SECURITY CAMERA VIDEO NVR PATCH RJ 45 TERMINATED/CERTIFIED PER EIA.TIA STANDARDS
Page 3: AT EARLY EDUCATION SCHOOL 990 CHURCH … · conduit fill is the sole responsibility of the ... CAT 6. CABLE FOR SECURITY CAMERA VIDEO TRANSMISSION RJ 45 TERMINATED/CERTIFIED PER …

1. THE PURPOSE OF THIS SHEET IS TO ILLUSTRATE AND DEFINE TYPICAL SYMBOLS, AND

SYSTEMS OF SYMBOLS, WHICH MAY OCCUR ON THE TELECOMMUNICATIONS

DRAWINGS. THE ILLUSTRATION OF A SYMBOL, OR SYSTEM OF SYMBOLS, ON THIS

SHEET DOES NOT NECESSARILY INDICATE THAT THE BUILDING ITEM OF THE

DESCRIBED SYSTEM BY THE SYMBOL IS USED AS PART OF THIS PROJECT. REFER TO

THE PLANS, ELEVATIONS, SECTIONS, SCHEDULES, DETAILS, AND SPECIFICATIONS TO

DETERMINE THE SCOPE OF THE WORK.

2. THE WORK - INCLUDING MATERIALS, METHODS, ASSEMBLIES, ETC - SHALL COMPLY

WITH THE MINIMUM REQUIREMENTS OF THE GOVERNING LAWS, ORDINANCES, AND

REGULATIONS OF ALL FEDERAL, STATE, AND LOCAL AUTHORITIES HAVING

JURISDICTION OVER THE PROJECT, AS WELL AS THOSE GREATER REQUIREMENTS

INDICATED BY THE CONTRACT DOCUMENTS. NO PART OF THE CONTRACT

DOCUMENTS MAY BE CONSTRUED TO REQUIRE OR PERMIT WORK CONTRARY TO A

GOVERNING LAW, ORDINANCE, OR REGULATION.

3. THE TELECOMMUNICATIONS DRAWINGS ARE PART OF THE OVERALL PROJECT

DRAWINGS WHICH, WHEN COMPLETE, CONSISTS OF DRAWINGS LISTED BY THE

"INDEX OF DRAWINGS". THE WORK DESCRIBED BY THE DRAWINGS OF ANY ONE

DISCIPLINE MAY BE AFFECTED BY THE WORK AND REQUIREMENTS DESCRIBED ON

DRAWINGS OF ANOTHER DISCIPLINE AND MAY REQUIRE REFERENCE TO THE

DRAWINGS OF ANOTHER DISCIPLINE. PARTIAL SETS OF DRAWINGS ARE INCOMPLETE

AND SHOULD NOT BE DISTRIBUTED OR UTILIZED BY THE CONTRACTOR. MANAGE,

SUPERVISE, REVIEW, AND COORDINATE THE WORK OF SUB-CONTRACTORS, TRADES,

AND SUPPLIERS WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS BEFORE

COMMENCING CONSTRUCTION AND TO ASSURE THAT PARTIES ARE AWARE OF

REQUIREMENTS, REGARDLESS OF WHERE THE REQUIREMENTS OCCUR IN THE

CONTRACT DOCUMENTS, WHICH MAY AFFECT THE WORK OF THAT PARTY.

4. THE ARCHITECTURAL DRAWINGS ESTABLISH AND COORDINATE THE FINISHED

APPEARANCE AND EXACT LOCATION OF EXPOSED ELEMENTS OF THE WORK OF

TRADES, INCLUDING THAT WORK THAT IS ILLUSTRATED PRIMARILY ON THESE

DRAWINGS. LOCATIONS SHOWN ON THESE DRAWINGS ARE DIAGRAMMATIC. REFER

TO ARCHITECTURAL DRAWINGS FOR DIMENSIONED LOCATIONS.

5. MAINTAIN A COPY OF THE SPECIFICATIONS AND DRAWINGS AT THE JOB SITE.

PRESENT THE SPECIFICATIONS AND DRAWINGS UPON REQUEST. MAINTAIN DAILY

MARKUPS OF ACTUAL INSTALLATION AND PRESENT FOR REVIEW UPON REQUEST.

6. REFER TO WRITTEN SPECIFICATIONS FOR PROJECT SCOPE, GENERAL

REQUIREMENTS, PRODUCT SPECIFICATIONS, AND INSTALLATION REQUIREMENTS.

WHERE QUANTITY AND QUALITY DIFFER, THE HIGHER OF EACH SHALL PREVAIL.

7. PROVIDE NECESSARY EQUIPMENT AND ACCESSORIES FOR A FULLY FUNCTIONAL

SYSTEM THAT MEETS INTENDED DESIGN WHETHER EXPRESSLY SPECIFIED OR NOT

AND ALL INCIDENTALS PERTAINING TO THE INSTALLATION TO FORM A COMPLETE AND

WORKING SYSTEM.

8. PROVIDE MATERIALS AND EQUIPMENT LISTED BY UNDERWRITERS LABORATORIES

FOR THE PURPOSE USED AND BEARING THEIR LABEL.

9. PRIOR TO PERFORMING WORK, IMMEDIATELY NOTIFY THE OWNER, OR OWNER'S

REPRESENTATIVE, IN WRITING OF OBSERVATIONS OR CONDITIONS DISCOVERED

THAT WOULD PREVENT INSTALLATION ACCORDING TO DRAWINGS AND

SPECIFICATIONS.

10. BRING A SET OF MARKED UP PLANS TO WEEKLY CONSTRUCTION MEETINGS FOR

OWNER'S, OR OWNER'S REPRESENTATIVE'S, APPROVAL PRIOR TO PRODUCTION OF

AS-BUILT DRAWINGS FOR RECORD DOCUMENTATION.

11. REMOVE ABANDONED CABLING LEFT OVER CONDUIT, WIRE, SCRAPS, ETC. LEAVE

PREMISES CLEAN AND FREE OF TRASH OR DEBRIS RESULTING FROM WORK. AND

PROPERLY RECYCLE APPLICABLE MATERIAL ACCORDING TO ALL CODE

REQUIREMENTS FOR SUCH MATERIAL.

12. INSTALL EQUIPMENT, DEVICES, AND PATHWAYS, SUCH AS CABLE TRAY, RUNWAY,

CONDUITS, CABLE HANGERS, AND PULLBOXES, ETC., ACCORDING TO STATE

AND LOCAL CODES AND REGULATORY REQUIREMENTS FOR SEISMIC BRACING.

13. CONDUIT ROUTING, WHERE SHOWN ON DRAWINGS, IS DIAGRAMMATIC IN NATURE.

FIELD DETERMINE CONDUIT ROUTES TO SUIT FIELD CONDITIONS WHILE CONFORMING

TO SPECIFICATIONS. PREPARE SHOP DRAWINGS SHOWING EXACT CONDUIT ROUTES,

INDICATING PENETRATION TYPES (e.g., FRAMED WALL, CONCRETE WALL, ETC.).

COORDINATE REQUIREMENTS WITH OTHER TRADES.

14. INSTALL CONDUIT PATHWAYS PER TIA/EIA-568-B AND BICSI TDMM AND BEST

INDUSTRY STANDARDS AND PRACTICES.

15. ROUTE CONDUIT, CABLE TRAYS, J-HOOKS AND OTHER PATHWAYS PERPENDICULAR

OR PARALLEL TO BUILDING LINES, IN GENERAL. CABLING INSTALLED AT ANGLES AND

SKEWED ABOVE CEILINGS WILL NOT BE ALLOWED.

16. CONDUITS WITH LESS THEN 2" INSIDE DIAMETER WILL HAVE A BEND RADIUS OF NO

LESS THAN 6 TIMES THE INSIDE DIAMETER. CONDUITS WITH A 2" OR GREATER INSIDE

DIAMETER WILL HAVE A BEND RADIUS OF NO LESS THAN 10 TIMES THE INSIDE

DIAMETER.

17. CONDUIT RUNS SHALL NOT EXCEED 180 DEGREES OR TWO 90-DEGREE BENDS

WITHOUT AN APPROPRIATE NEMA RATED PULL BOX OR/AND INCREASE CONDUIT BY

ONE TRADE SIZE FOR EACH ADDITIONAL BEND OF UP TO 90 DEGREES, UNLESS LAST

BEND IS WITHIN 12 INCHES OF THE CONDUIT END.

18. WHEN ROUTING CONDUIT IN CONCRETE, MAINTAIN A GRADUATED BEND RADIUS TO

MAINTAIN CONDUIT CAPACITY. THE USE OF 90-DEGREE 'ELBOW' FITTINGS IS

EXPRESSLY PROHIBITED UNLESS PRIOR AUTHORIZATION IS RECEIVED FROM OWNER,

OR OWNER'S REPRESENTATIVE, IN WRITING.

19. PROPERLY FIRE SEAL CONDUIT AND RACEWAY PENETRATIONS THROUGH FIRE

RATED WALLS AND FLOORS TO MAINTAIN THE FIRE SEPARATION RATING. PROVIDE

FIRE SEALING ASSEMBLIES THAT ARE UL LISTED FOR THE APPLICATION.

COORDINATE REQUIREMENTS WITH LOCAL FIRE MARSHALL PRIOR TO INSTALLATION.

DO NOT MIX PRODUCTS BETWEEN MANUFACTURED ASSEMBLIES.

20. PROVIDE EXPANSION/DEFLECTION FITTINGS FOR CONDUITS AT STRUCTURAL

EXPANSION JOINT CROSSINGS.

21. PROVIDE PLASTIC BUSHINGS ON EXPOSED ENDS OF CONDUIT AND SLEEVES,

WHETHER VISIBLE OR NOT.

22. PROVIDE EMT 4" TRADE SIZE CONDUITS FOR BACKBONE PATHWAYS WITH 40"

MINIMUM BEND RADIUS FITTINGS, UON.

23. PROVIDE MINIMUM OF 1 INCH SIZE CONDUIT FOR HORIZONTAL DISTRIBUTION AND

TELECOMMUNICATIONS DEVICES. CONSOLIDATION OF CONDUITS IS ALLOWED WHEN

EQUAL OR GREATER CONSOLIDATED AREA IS PROVIDED.

24. PROVIDE DEDICATED CONDUIT STUB PER TELECOMMUNICATIONS DEVICE BOX.

DAISY-CHAINING DEVICE BOXES IS PROHIBITED UNLESS SPECIFICALLY NOTED ON

FLOOR PLANS.

25. CONDULET ("LB", ETC.) FITTINGS ARE EXPRESSLY PROHIBITED FOR

TELECOMMUNICATIONS SYSTEM PATHWAYS.

26. PROVIDE A PULL STRING OR PULL ROPE IN EMPTY/UNUSED DISTRIBUTION CONDUITS

AND CONDUITS SERVING TELECOMMUNICATIONS DEVICES SUITABLE FOR A 200 LB

PULL TENSION MINIMUM.

27. PROVIDE DEDICATED SUPPORTS (e.g., CLIPS & WIRES) FOR CABLE SUPPORT

HANGERS (OR SIMILAR PATHWAY COMPONENTS) INTENDED FOR

TELECOMMUNICATIONS CABLES.

28. ALL NEW TELECOM DEVICES FOR NEW CONSTRUCTION SHALL BE FLUSH MOUNTED

AND RECESSED IN WALLS, ALL CONDUITS, CABLING, ETC. SHALL BE CONCEALED IN

WALLS AND ABOVE SUSPENDED AND HARD LID CEILINGS.

29. PROVIDE SLEEVES AS REQUIRED WHERE CABLES PASS THROUGH RATED WALLS

30. SURFACE WIREWAY OR DEVICES SHALL BE ALLOWED AS SHOWN ON DRAWINGS,

U.O.N..

38. LABEL TELECOMMUNICATIONS CABLES ACCORDING TO SPECIFICATIONS.

PROVIDE LABELS AT BOTH ENDS, FACEPLATES, PATCH PANELS, ETC.

LABELING SCHEMA SHALL BE COORDINATED SO THAT ALL LABELING,

WHETHER ON FACEPLATE OR CABLE MATCHES CABLE DESCRIPTORS

END TO END. PROVIDE SAMPLE LABELS TO THE OWNER, OR OWNER'S

REPRESENTATIVE AND OBTAIN WRITTEN APPROVAL PRIOR TO LABELING

(VERIFY FORMAT AND REQUIRED FIELDS OF INFORMATION).

39. COMPONENTS NOT RELATED TO THE SUPPORT OF THE

TELECOMMUNICATIONS ROOM(S) FUNCTION (E.G.,PIPING, DUCTWORK,

PNEUMATIC TUBING, ETC.) SHALL NOT BE INSTALLED IN, PASS THROUGH,

OR ENTER THE TELECOMMUNICATIONS ROOM.

40. IT IS FORBIDDEN TO ROUTE ANY LIQUID CARRYING SYSTEMS, INCLUDING

VALVES OR RUBBER TUBING COMPONENTS CONTAINING LIQUID

THROUGH TELECOM ROOMS AND SPACES

41. OUTLET AND DEVICE LOCATIONS SHOWN ARE APPROXIMATE AND SHALL

BE COORDINATED IN THE FIELD WITH SFUSD. WIREWAY, CONDUITS,

OUTLETS, ETC. WILL REQUIRE ADJUSTMENT IN PATHWAYS, FOR BUILDING

FEATURES, ARCHITECTURAL FEATURES AND AVOIDING CONFLICT WITH

FURNITURE, SHELVING, DESKS, ETC. WIREWAYS,CONDUITS , ETC. SHALL

BE ROUTED IN A MANNER TO COORDINATE WITH ALL EXISTING

CONDITIONS ON SITE.

31. DO NOT SHARE SUPPORTS WITH OTHER TRADES/SYSTEMS, INCLUDING SECURITY

AND/OR AUDIOVISUAL SYSTEMS. PROVIDE WIRES, HANGERS, ETC. SEPARATE FROM

THE CEILING SUPPORT SYSTEM AND OTHER INSTALLED SYSTEMS, A DEDICATED

SUPPORT SYSTEM IS REQUIRED FOR TELECOMMUNICATIONS CABLING.

32. PROVIDE TELECOMMUNICATION CONDUITS FOR CABLING ROUTED THROUGH

NON-ACCESSIBLE CEILING SPACE (e.g., 'HARD LID' CEILING), UON. SIZE CONDUITS

TO MAINTAIN A FILL CAPACITY NO LESS THAN 40% PLUS 50% SPARE CAPACITY.

33. INSTALL TELECOMMUNICATIONS DEVICES AT HEIGHTS NOTED ON SYMBOLS LIST

OR DEVICE SCHEDULE, UNLESS OTHERWISE SHOWN ON THE DRAWINGS OR

STATED IN SPECIFICATIONS. MOUNTING HEIGHTS ARE FROM FINISHED FLOOR TO

THE CENTERLINE OF THE DEVICE. REFER TO ARCHITECTURAL ELEVATION

DRAWINGS FOR ADDITIONAL INFORMATION OR EXACT LOCATIONS OF

WALL/CEILING/FLOOR MOUNTED DEVICES. VERIFY HEIGHTS ARE THE SAME AS

ACCOMPANYING POWER RECEPTACLES AND NOTIFY OWNER, OR OWNER'S

REPRESENTATIVE OF ANY DISCREPANCY.

34. PROVIDE A 24" MINIMUM SEPARATION BETWEEN 'BACK-TO-BACK'

TELECOMMUNICATION POWER OR SIGNAL DEVICES IN FRAMED WALLS.

35. DO NOT TIE CABLES TO OTHER STRUCTURES NOT INTENDED FOR THIS SPECIFIC

USE. DO NOT TIE CABLES TO CABLE TRAY.

36. ROUTE TELECOMMUNICATIONS CABLES PERPENDICULAR OR PARALLEL TO

BUILDING LINES, IN GENERAL. ROUTE TELECOMMUNICATIONS CABLES NO LESS

THAN 6 INCHES FROM ANY POWER SOURCE OR FLORESCENT LIGHTING FIXTURE,

AND NO LESS THAN 4 FEET FROM ANY TRANSFORMER OR MOTOR.

37.. GROUP AND DRESS EXPOSED TELECOMMUNICATIONS CABLE GROUPS USING

VELCRO TIES, UON. GROUP NO MORE THAN 20 CABLES IN A NGLE BUNDLE AS

ESTABLISHED FOR PoE EQUIPMENT.

TY-03

GENERAL NOTES AND

PROJECT NOTES

1. DEVICES NOT ASSOCIATED WITH OR SHOWN ADJACENT TO

CABLE TRAY SHALL BE ROUTED IN CONDUIT TO CABLE TRAY

TO CABLE TRAY SYSTEM. CONDUIT RUNS FOR SAME SYSTEMS

MAY BE COMBINED BY SIZING TO THE NEXT TRADE SIZE

AND/OR ENSURING A MAXIMUM OF 40% FILL RATIO. A

MAXIMUM OF 2 RUNS FROM VOICE AND DATA SHALL BE

PERMITTED PER CONDUIT RUN.

2. CABLE TRAY SHALL BE FILLED TO A MAXIMUM OF 50% PER

THE CABLE TRAY FILL CHART.

3. DO NOT COMBINE CABLES FROM OTHER SYSTEMS INTO

COMMON CONDUIT RUNS. EACH SYSTEM SHALL HAVE A

SEPARATE CONDUIT RUN TO THE CABLE TRAY.

4. ALL CABLE TRAY IS TO BE INSTALLED TO MAKE EFFICIENT

USE OF THE SPACE ABOVE SUSPENDED CEILING SYSTEMS.

COORDINATE ALL TRAY LOCATIONS WITH ELECTRICAL AND

MECHANICAL SYSTEMS TRAVERSING HALLWAYS AND CORRIDORS,

ADJUST ROUTES AS NECESSARY. CABLE TRAY SHALL HAVE A

MINIMUM OF 9" WORKING CLEARANCE ABOVE TRAY.

5. REFER TO RISER DIAGRAMS FOR SYSTEMS INTERCONNECTION

AND CABLING REQUIREMENTS

6. COORDINATE VOICE AND DATA OUTLET LOCATIONS WITH

ELECTRICAL OUTLETS AND INSTALL A STUD BAY APART ALONG

COMMON USE WALLS.

7. COORDINATE ALL MOUNTING HEIGHTS OF DEVICES, OUTLETS,

ETC.., IN CASEWORK AND FURNITURE, SEE ARCHITECTURAL

ELEVATIONS FOR MOUNTING HEIGHTS OF OUTLETS AND

DEVICES.

8. CABLE TRAY THROUGH EXTENDED HARD LID AREAS SHALL BE

TRANSITIONED WITH SLEEVES AND FIRE STOPPING OR BY

PLACING MULTIPLE 4" CONDUITS BETWEEN ACCESSIBLE

CEILING SPACES, WHILE MAINTAINING CABLE TRAY CAPACITIES.

9. IT IS THE INTENT THAT ALL VOICE, DATA BE

INSTALLED IN THE COMMON CABLE TRAY SYSTEM ONLY.

OTHER SYSTEMS SUCH AS PAGING, SECURITY, ETC. SHALL BE

INSTALLED IN A J-HOOK SYSTEM, PARALLEL TO THE CABLE

TRAY. LIKE SYSTEMS CABLES SHALL BE INSTALLED ON

SEPARATED HOOKS IN THE J-HOOK PATHWAY AND BUNDLED

WITH VELCRO TYPE STRAPS, AND BY PLACING CABLES IN

ADJACENT J-HOOKS IN THE CABLE ROUTE. DRESS CABLING IN

COMMON GROUPS AND TYPES.

10. NEW CONDUITS, ETC..... ARE TO BE INSTALLED AROUND

BUILDING STRUCTURES, FEATURES, BEAMS, SUPPORTS ETC.....,

CONDUITS FEEDING DEVICES SHALL BE ROUTED DOWN TO THE

INSTALLATION HT. OF THE DEVICES AND STUBBED INTO

THE COMMON AREA TO CONNECT TO CABLE TRAYS.

PREPLANNING PATHWAYS AND ROUTES IS REQUIRED TO BE

FIELD COORDINATED PRIOR TO INSTALLATION. INCLUDE ALL

COSTS FOR ROUTES HORIZONTAL AND VERTICAL TO FACILITATE

DESIGN AND INTENT. PROVIDE NECESSARY BACKING OR

FURRING OF WIREWAY, CABLE TRAY, CONDUIT ETC.. TO

ROUTE AROUND MECHANICAL AND/OR ELECTRICAL SYSTEMS.

11. ALL CONDUIT CABLE RUNS TO CABLE TRAY SHALL BE

SLEEVED THRU WALLS WITH CONDUIT AND BUSHED WITH SNAP

ON BUSHINGS EACH END PRIOR TO CABLE INSTALLATION.

ROUTES WHICH PASS THRU RATED WALLS SHALL USE THE

APPROPRIATE SIZED FLAMESTOPPER OR U.L. ASSEMBLY,

SIMILAR TO IDF, SIZED FOR CABLE FILL. THIS APPLIES TO

ALL CABLES IN CEILING SPACE WITH PASS THRU GYP BOARD

WALLS IN ROUTE TO CABLE TRAY.

12. CONDUIT AND RATED SLEEVES FEEDING CABLE TRAYS SHALL

BE USED 100% OF CAPACITY PRIOR TO CABLING BEING

ADDED OR EXTENDED TO THE NEXT OPEN SLEEVE.

13. ALL CONDUITS SHALL HAVE PLASTIC SNAP ON BUSHINGS NOT

PRESS ON STYLE, INSTALLED PRIOR TO ANY CABLE

INSTALLATION.

14. REFER TO ARCHITECTURAL DRAWINGS (REFLECTED CEILING

PLANS, AND INTERIOR ELEVATIONS, ETC....) FOR

COORDINATION, WHICH INCLUDES LIGHTING FIXTURES,

SWITCHES, OUTLETS, SECURITY SYSTEMS, SMOKE DETECTORS,

MECHANICAL SYSTEMS ETC.... FOR DEVICE AND SYSTEM

COMPONENT LOCATIONS.

15. MAINTAIN FIRE RATING OF ALL FLOORS, CEILING AND

WALLS PENETRATED BY ELECTRIC WORK.

16. ALL DEVICES INDICATED MOUNTED BACK TO BACK

SHALL BE SEPARATED BY A WALL STUD. BOXES ARE

NOT TO BE MOUNTED IN SAME WALL CAVITY. PROVIDE

3M BRAND FIRE BARRIER MOLDABLE PUTTY MPP-1 AND

APPLY TO BOX MOUNTED IN FIRE RATED WALL PER

CONTRACT DOCUMENTS. IN FIRE RATED WALLS AND

PARTITIONS, OFFSET OUTLET BOXES A MINIMUM OF 24

INCHES HORIZONTALLY.

17. ALL ELECTRICAL EQUIPMENT SHALL BE BRACED OR ANCHORED

TO RESIST A HORIZONTAL FORCE ACTING IN

ANY DIRECTION PER THE FOLLOWING CRITERIA:

A. FIXED EQUIPMENT ON GRADE. 33% OF OPERATING

WEIGHT

B. FIXED EQUIPMENT ON STRUCTURE. 50% OF

OPERATING WEIGHT

C. COMMUNICATION SYSTEMS/CONDUIT/CABLE TRAY,

ETC.... ON GRADE: 50% OF OPERATING WEIGHT

D. COMMUNICATION SYSTEMS/CONDUIT/CABLE TRAY ON

STRUCTURE. 75% OF OPERATING WEIGHT

ALL CABLE TRAY AND SYSTEMS SHALL BE INSTALLED TO MEET

SEISMIC ZONE 4 REQUIREMENTS. PROVIDE ALL LATERAL

BRACING AND BUILDING ATTACHMENTS TO PRECLUDE

MOVEMENT OF CONDUITS, CABLE TRAYS, ETC.... WITHIN THE

HORIZONTAL AND VERTICAL PLANES.

18. SUPPORT AND SEISMIC BRACING OF ALL CONDUITS AND

CABLE TRAY SHALL BE IN ACCORDANCE WITH THE SMACNA

GUIDELINES FOR SEISMIC RESTRAINTS OF ELECTRICAL SYSTEMS

AND PRE-APPROVED ANCHORAGE DETAILS WHICH ARE PRE

APPROVAL, B-LINE BY OSHPD APPROVAL No. R0114

19. PROVIDE ANCHORS IN HARDENED CONCRETE (NORMAL OR

LIGHTWEIGHT). PROVIDE CAST-IN-PLACE ANCHORS IF

EXPANSION ANCHORS ARE USED.

20. DETAILS SHOWN ON THESE DRAWINGS ONLY SHOWS THE

INTENT OF THE DESIGN. ACTUAL EQUIPMENT ANCHORAGE

SHALL BE COORDINATED WITHIN THE STRUCTURAL BLDG..

REQUIREMENTS.

21. ALL DATA AND VOICE CABLES SHALL NOT BE PLACED WITHIN

THE BUILDING EXCEEDING 295', WHICH IS THE ESTABLISHED

MAXIMUM LENGTH LIMIT. CONTRACTOR TO COORDINATE

SHORTEST ROUTE AND PATHWAYS FROM INDIVIDUAL OUTLETS

TO EACH FLOORS TELECOM/IDF ROOM.

22. CABLE TRAY SHALL BE INSTALLED WITHOUT BARRIERS FOR

VOICE AND DATA CABLING IN THE HORIZONTAL TRAY

WITHIN CORRIDORS TO ALLOW FULL USE OF TRAY.

23. THE SECURITY SYSTEM SHALL NOT PREVENT EGRESS

THROUGH ANY CONTROLLED DOOR IN THE EVENT OF ANY

FIRE ALARM WITHIN THE BLDG.. OCCUPANTS SHALL HAVE FREE

EGRESS THROUGH ALL DOORS WHICH ARE PROVIDED WITH

DOOR PANIC HARDWARE. ALL EXIT DOORS ARE AND SHALL

BE OPERABLE WITHOUT SPECIAL KEYS OR HARDWARE, SPECIAL

KNOWLEDGE OR EFFORT.

24. WEATHERPROOF OR MOISTURE RESISTANT TYPE OUTLETS,

SWITCHES, ETC.. SHALL BE PROVIDED WITH A HINGED CAP OR

SCREW ON TYPE CAB ASSEMBLY OVER EACH ENTRANCE TO

THE CONNECTOR, RECEPTACLE OR DEVICES TO PRECLUDE

WATER DAMAGE.

25. COORDINATE ALL DOOR HARDWARE INTERFACE CONTROLS,

CONNECTIONS TO OTHER SYSTEMS, POWER SUPPLIES, ETC..

WITH OTHER TRADES. PROVIDE FULL LAYOUT AND

INTERCONNECT DETAILS WITHIN THE SHOP DRAWING PHASE

FOR ALL CARD ACCESS DOOR CONTROL ASSEMBLIES

26. COORDINATE ALL CABLE TRAY RUNS, CONDUITS, DEVICES,

OUTLETS, ETC.. INSTALLED ABOVE HARD LID OR T-GRID TYPE

CEILINGS WITH REFLECTED CEILINGS PLANS, ELECTRICAL

PLANS, MECHANICAL PLANS AND ARCHITECTURAL PLANS AND

DETAILS FOR FORM, FIT AND FUNCTION.

27. CONTRACTOR TO PROVIDE COORDINATED SHOP DRAWINGS FOR

TELECOM, VOICE, DATA AND SECURITY SYSTEM CABLING,

INFRASTRUCTURE, DEVICES, MOUNTING, ETC.. SEE

SPECIFICATIONS.

28. ALL WORK SHALL BE IN ACCORDANCE WIT H THE LATEST

EDITION OF THE CALIFORNIA ELECTRICAL CODE UNDER ARTICLES

720, 725 AND 800 AND THE NATIONAL ELECTRICAL CODE. THE

CONTRACTOR SHALL NOT INTERMIX ANY HIGH VOLTAGE POWER

WIRES (120VAC) WITH ANY LOW VOLTAGE SIGNAL OR CONTROL

WIRES IN ANY CONDUIT.

29. VERIFY ALL FIELD DIMENSIONS AND CONDITIONS, NOTIFY

ARCHITECT OF ANY DISCREPANCIES FOUND. VERIFY DIMENSIONS

OF ALL OWNER FURNISHED OPERATING EQUIPMENT TO ENSURE

PROPER COORDINATION WITH CONSTRUCTION

30. SCHEDULE ALL WORK INCLUDING CONSTRUCTION ACCESS AND

STORAGE WITH THE OWNER OR THOSE DESIGNATED BY THE

OWNER. THE CONSTRUCTION SCHEDULE SHALL BE APPROVED BY

THE OWNER PRIOR TO THE START OF CONSTRUCTION.

31. ALL UTILITIES REQUIRED FOR THE CONTINUOUS OPERATION OF

ALL EXISTING FACILITIES MUST BE MAINTAINED IN SERVICE AT

ALL TIMES (AS APPLICABLE).

32. CONTRACTOR SHALL PROVIDE DUST AND DEBRIS PROTECTION AS

NECESSARY TO CONTAIN DUST AND DEBRIS WITHIN THE

CONSTRUCTION AREA, BROOM CLEAN ALL AREAS DAILY.

33. COORDINATE WITH THE OWNER TO DETERMINE IF REMOVED DEMO

ITEMS (AS APPLICABLE) WILL BE RETAINED BY THE OWNER.

COORDINATE STORAGE AND INVENTORY OF DEMO DEVICES AND

DELIVER TO OWNER. DISPOSAL OF OLD EQUIPMENT, DEMO ITEMS

NOT RETAINED SHALL BE DONE IN ACCORDANCE WITH ALL

FEDERAL, STATE AND LOCAL CODES.

34. ALL WORK SHALL BE EXECUTED IN A CAREFUL AND ORDERLY

MANNER, WITH THE LEAST POSSIBLE DISTURBANCE TO THE

PUBLIC AND OCCUPANTS OF EXISTING BUILDINGS. NO

INTERRUPTION TO WORKING PERSONNEL WILL BE PERMITTED,

WORK IN AREAS SHALL BE DONE AFTER NORMAL WORKING

HOURS.

35. CONTRACTOR SHALL PROVIDE ALL BARRIERS, SIGNS, AREA

PROTECTION, SAFETY BARRIERS, ETC. TO KEEP PERSONNEL OUT

OF WORK AREA.

36. NO POWER SHALL BE SHUT DOWN DURING NORMAL WORKING

HOURS WITHOUT PRIOR CONSENT OF OWNER.

37. CONTRACTOR SHALL ASSUME SOLE RESPONSIBILITY FOR SAFETY

OF ALL PERSONS ON OR ABOUT THE CONSTRUCTION SITE IN

ACCORDANCE WITH APPLICABLE LAWS AND CODES. GUARD ALL

HAZARDS IN ACCORDANCE WITH SAFETY PROVISIONS OF THE

LATEST MANUAL OF ACCIDENT PREVENTION, PUBLISHED BY THE

ASSOCIATED GENERAL CONTRACTORS OF AMERICA.

38. COORDINATION WITH OTHER CONTRACTORS:

IF ANY PART OF THE CONTRACTORS WORK DEPENDS

UPON THE WORK OF ANOTHER CONTRACTOR OR TRADE,

THIS CONTRACTOR SHALL INSPECT SUCH WORK AND

PROMPTLY REPORT IN WRITING TO THE PROJECT

ARCHITECT ANY DEFECTS IN SUCH WORK THAT RENDER IT

UNSUITABLE TO RECEIVE THE WORK THIS THIS

CONTRACTOR. FAILURE TO INSPECT AND REPORT SHALL

CONSTITUTE AN ACCEPTANCE OF THE OTHER

CONTRACTORS OR TRADES WORK, EXCEPT AS TO DEFECTS

WHICH DEVELOP IN OTHER CONTRACTORS WORK AFTER

EXECUTION OF THIS CONTRACTORS WORK.

39. THE CONTRACTOR SHALL ALWAYS MAINTAIN AT THE JOB SITE AN

UPDATED "RECORD" SET OF DRAWINGS AND AS-BUILTS OR AS

INSTALLED DRAWINGS. THE DRAWINGS SHALL BE AVAILABLE TO

THE ARCHITECTS, ENGINEERS AND OR INSPECTORS UPON

REQUEST.

40. CABLE RUNS SHALL NOT BE SPLICED UNLESS TWO OR MORE

DEVICES ARE CONNECTED TO THE SAME CIRCUIT OR THE DEVICE

IS PROVIDED WITH FACTORY PIGTAIL WIRES. WHERE SPLICING IS

REQUIRED, THE SPLICE SHALL BE SOLDERED AND TAPED.

SPLICING SHALL BE DONE IN A TERMINAL BOX OR CABINET, OR

AT THE BACK BOX OF THE DEVICE OR TERMINAL LUGS. ALL

SPLICE BOXES MUST BE ACCESSIBLE AND CLEARLY MARKED ON

THE RECORD DRAWINGS (NOT APPLICABLE TO TELECOM OR

FIBER)

41. ALL WIRES AND CABLES SHALL BE COLOR CODED AND SHALL

BE CONNECTED IN A UNIFORM MANNER. TRANSPOSING OR

CHANGING OF COLOR CODES SHALL NOT BE PERMITTED. WIRE

AND CABLE SIZES, NUMBER OF CONDUCTORS, SHIELDING OR

OTHER ITEMS LISTED ON THESE DRAWINGS SHALL NOT BE

ALTERED OR CHANGED IN TYPE GAUGE OR ELECTRICAL CAPACITY.

42. ALL WIRING AND CABLING, INCLUDING SHIELDS MUST BE FREE

OF SHORTS, GROUNDS AND STRAY OR INDUCED VOLTAGES. ALL

UNDERGROUND OR BELOW GRADE CABLES AND WIRES MUST BE

RATED FOR WET LOCATIONS. ALL EXPOSED CABLE BELOW 12'

AFF SHALL BE IN CONDUIT U.O.N.

43. THE MAIN SECURITY CABLING CABLE TRAY, J-HOOK ROUTES

SHALL RUN PARALLEL AND PERPENDICULAR TO THE BUILDING

AND ADJACENT TO VOICE AND DATA CABLING SYSTEMS. EACH

CONTRACTOR AND SYSTEM SUPPLIER SHALL BE RESPONSIBLE

FOR PROVIDING ALL J-HOOK PATHWAYS AND ROUTES FOR

RESPECTIVE SYSTEMS BEYOND CABLE TRAYS, THIS INCLUDES ALL

CONDUITS, BOXES, FITTINGS ETC.

44. ALL CABLING WITHIN SYSTEMS SHALL BE INSTALLED WITH WRAP

AROUND IMPRINTED TYPE LABELING SYSTEM AS FOLLOWS:

A. CABLES WITHIN 6" UPON ENTRY TO ANY PANEL,

TERMINATION OR SPLICE BOX

B. ALL WIRE LEADS WITHIN 2" FROM ANY TERMINAL BLOCK

CONTRACTOR SHALL SUBMIT SAMPLES FOR APPROVAL OF

MARKING SYSTEM LABELS

ALL ELECTRICAL POWER SUPPLIED TO EQUIPMENT OR DEVICES

SHALL BE ON AN EMERGENCY SYSTEM (WHERE AVAILABLE). ALL

CONDUCTORS AND CIRCUIT BREAKERS SHALL BE SIZED IN

ACCORDANCE WITH THEIR CONNECTED LOADS (20 AMP

MINIMUM) ALL CIRCUITS SHALL BE DEDICATED. A GROUND

CONDUCTOR SHALL ALWAYS BE INSTALLED IN POWER WIRING

CONDUITS, ALL EQUIPMENT AND PANELS SHALL BE GROUNDED.

45. WHERE A CIRCUIT FOR SECURITY EQUIPMENT IS ORIGINATING

FROM A LOAD CENTER UTILIZED FOR OTHER ELECTRICAL

PURPOSES, THE BRANCH CIRCUIT BREAKER FOR SECURITY

EQUIPMENT SHALL BE THE LOCKABLE TYPE TO PREVENT ANY

ACCIDENTAL DISRUPTION AND POWER DISCONNECTION. ALL

SECURITY BRANCH CIRCUITS SHALL BE DEDICATED.

46. THE CONTRACTOR SHALL SEAL ALL CONDUIT OR SLEEVE

PENETRATIONS THROUGH ALL WALLS, FLOORS AND CEILING

USING U.L. APPROVED AND LISTED METHODS AND COMPOUNDS,

REGARDLESS OF RATINGS IN ACCORDANCE WITH APPLICABLE

BUILDING CODES. THIS PERTAINS TO ALL WALLS, FLOORS,

CEILINGS, ETC. WHETHER RATED OR NOT.

47. ALL ROUTING OF WIRING AND RELATED CONDUITS IF SHOWN ARE

DIAGRAMMATIC IN NATURE. CONTRACTOR SHALL FIELD VERIFY

EXACT ROUTING, FORM, FIT AND FUNCTION PRIOR TO

INSTALLATION.

48. CONTRACTOR SHALL PROVIDE PULL STRINGS, ROPES OR LINES

AS APPLICABLE FOR CONDUIT SIZE, SYSTEM AND FUNCTION.

49. ALL CONDUITS SHALL RUN PARALLEL OR PERPENDICULAR TO

WALLS, CEILINGS, FLOORS, ETC.. IF MORE THAN TWO 90 DEGREE

BENDS ARE TO BE INSTALLED IN A CONDUIT RUN, OR THE

CONDUIT IS LONGER THAN 100 FEET THE

CONTRACTOR SHALL PROVIDE THE NECESSARY PULL BOXES,

APPROPRIATELY SIZED AND FOR FUNCTION (NEMA1, 3R, ETC.).

CONDUITS SHALL BE SIZED AS SHOWN OR LARGER AS REQUIRED

TO COMPLY WITH CODE, MINIMUM CONDUIT SIZE 1" U.O.N.

50. CONTRACTOR SHALL CLEAN AND THOROUGHLY CHECK ALL

INSTALLED WORK PRIOR TO CONCEALING OF WORK. CLEAN ALL

EXPOSED SURFACES AND NEW EQUIPMENT UPON INSTALLATION

AND PRIOR TO PLACING INTO SERVICE. THE CONTRACTOR SHALL

REPAIR, CLEAN, ETC. ALL SOILED SURFACES, PAINTED SURFACES

OR DAMAGED ARCHITECTURAL BUILDING FINISHES TO MATCH THE

ADJACENT ERAS, WHERE REQUIRED PRIOR TO COMPLETION.

CLEANING, PATCHING, PAINTING TO RESTORE SURFACES TO

ORIGINAL FINISHES SHALL BE THE RESPONSIBILITY OF THIS

CONTRACTOR FOR SYSTEMS AND/OR DEVICES INSTALLED BY THIS

WORK SCOPE.

51. ALL EQUIPMENT AND DEVICES SHALL BE INSTALLED WITH

CONSIDERATION TO BARRIER FREE ACCESSIBILITY, AS DEFINED IN

CALIFORNIA TITLE 24.

52. WHERE CONCRETE FLOORS ARE TO BE CORED, AN X-RAY

SHALL BE TAKEN TO ENSURE THAT NO STRUCTURAL ELEMENTS

WILL BE DAMAGED DURING CORING.

53. SHOULD THE CONTRACTOR BE REQUIRED TO CHANGE ANY

DEVICE OR INSTALLATION TO SUIT THE ARCHITECTURAL FEATURES

OF THE BUILDING, THE WORK SHALL BE INCLUDED AS PART OF

THIS WORK SCOPE, ADJUSTED AND MODIFIED AS NECESSARY.

CHANGES AFFECTING BUILDING APPEARANCE SHALL BE BROUGHT

TO THE ATTENTION OF THE ARCHITECT PRIOR TO INSTALLATION.

54. COORDINATE ALL LOW VOLTAGE SYSTEMS WORK, INSTALLATION

AND CONNECTION WITH OTHER TRADES AND WITH OWNER

REQUIREMENTS.

55. THE CONTRACTOR SHALL UNDERTAKE THIS WORK IN ITS

ENTIRETY IN ACCORDANCE WITH DESIGN AND PURPOSE. ALL

WORK SHALL BE PERFORMED IN A PROFESSIONAL MANNER,

QUALITY, EFFICIENCY AND WORKMANSHIP.

56. THE CONTRACTOR SHALL INCLUDE ANY COORDINATION, RELAYS,

TIMERS, NETWORK CARDS, TERMINAL STRIPS, ETC. AS REQUIRED

FOR A COMPLETE AND OPERATIONALLY FUNCTIONING SYSTEM TO

INTERFACE WITH ELEVATOR CONTROLLERS, FIRE ALARM SYSTEMS,

DOOR HARDWARE AND AUTOMATIC DOOR OPENING DEVICES,

WHERE APPLICABLE.

57. ALL EXIT DOORS SHALL REMAIN FREE OPENING FROM EXIT SIDE

VIA PANIC HARDWARE, U.O.N.

58. PENETRATIONS THROUGH FIRE-RATED FLOORS, WALLS AND

CEILINGS SHALL BE PROTECTED IN ACCORDANCE WITH CBC

SECTION 709.6 AND 710.1. SYSTEMS SHALL BE INSTALLED IN

ACCORDANCE WITH MANUFACTURERS INSTALLATION INSTRUCTIONS

AND APPROVED LISTING. MANUFACTURERS INSTALLATION

INSTRUCTIONS AND APPROVED LISTINGS SHALL BE PROVIDED

FOR REVIEW UPON REQUEST. ANY SUBSTITUTIONS OF APPROVED

MATERIALS OR METHODS SHALL BE SUBMITTED FOR APPROVAL

PRIOR TO INSTALLATION

59. IN THE EVENT OF DISCREPANCIES BETWEEN THE SPECIFICATIONS

AND CONTRACT DRAWINGS, WHICHEVER IS THE MORE STRINGENT

REQUIREMENT OR MANDATES THE HIGHEST QUALITY OR QUANTITY,

SHALL PREVAIL.

61. NO PIPES OR CONDUITS SHALL BE PLACED OR ROUTED

THROUGH TELECOMMUNICATIONS OR SERVER ROOMS UNLESS

THEY ARE DEDICATED TO THE TELECOM OR SERVER ROOM. ALL

DEDICATED PIPES AND CONDUITS SHALL BE ROUTED AS HIGH AS

PRACTICABLE IN THE ROOM, TIGHT TIGHT TO CEILING TO

PRECLUDE INTERFERENCE WITH OTHER SYSTEMS, LIGHTING,

POWER ETC. FEEDING RACKS AND EQUIPMENT.

62. ALL HORIZONTAL FIBER OPTIC CABLES SHALL BE INSTALLED IN

CONTINUOUS INNER DUCT FROM SERVER ROOMS TO IDF ROOMS.

INNER DUCT SHALL BE SECURED TO CABLE TRAY BELOW

COPPER CABLES.

63. VELCRO TY-WRAPS ARE TO BE USED WITHIN THE TR'S ONLY

NO ELECTRICAL TAPE OR TY-WRAPS ARE TO BE USED WITHIN

THE CEILING SPACES.

64. CONTRACTOR SHALL NOTIFY A UCD COMMUNICATIONS RESOURCE

REPRESENTATIVE A MINIMUM OF 48 HOURS IN ADVANCE BEFORE

THEY TEST AND CABLING WITHIN THE BUILDING. NO TESTING

SHALL BE PERFORMED UNTIL A COMMUNICATION RESOURCES

REPRESENTATIVE APPROVES THE TEST EQUIPMENT, METHODS AND

TEST SETTINGS. ANY TESTING COMPLETED BEFORE CR

APPROVAL WILL BE NULL AND VOID AND SHALL BE RETESTED

AT NO ADDED COST TO UCD IN COMPLIANCE OF CR STANDARDS

AND THE ABOVE CRITERIA.

65. ALL VOICE CABLING AND CROSSCONNECTS SHALL TESTED WITH A

FIELD RECORDABLE DEVICE AND RECORDS PRESENTED UPON

COMPLETION. TESTING SHALL COMPLY WITH NOTE #64 ABOVE.

66. ALL FIBER TESTING AND CROSSCONNECTS SHALL BE TESTED

WITH A FIELD RECORDABLE DEVICE AND RECORDS PRESENTED

UPON COMPLETION. TESTING SHALL COMPLY WITH NOTE

#64 ABOVE.

SITE NO.

SCALE

DATECHECKED BY

S.F.U.S.D. PROJECT NO.

SHEETS

DRAFTER

OF

XXXX05/31/18 JSM -

12064

CONSTRUCTION

DESIGN &

FACILITIES

135 Van Ness Avenue

San Francisco, California 94102

Tel (415) 355-6979

Fax (415) 355-6988

Architect Engineer

School Name and Address

Project Name

Date No. Revisions

SHEET NO.

DRAWING TITLE

Approvals

AS NOTED

SFUSD SAN FRANCISCOPUBLIC SCHOOLS

Consultant Name and Address

05/15/2018 - BID ISSUE

G U T T M A N N B L A E V O E T

C O N S U L T I N G E N G I N E E R S

E

P F

THERESA MAHLER

EARLY EDUCATION SCHOOL

990 CHURCH STREET

SAN FRANCISCO, CA 94114

SFUSD PROJ. #12064

SECURITY

IMPROVEMENTS

AutoCAD SHX Text
PROJECT NOTES
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text
2351 Powell Street
AutoCAD SHX Text
&
AutoCAD SHX Text
415 655 4000 415 655 4001
AutoCAD SHX Text
San Francisco, CA. 94133-1449
AutoCAD SHX Text
Page 4: AT EARLY EDUCATION SCHOOL 990 CHURCH … · conduit fill is the sole responsibility of the ... CAT 6. CABLE FOR SECURITY CAMERA VIDEO TRANSMISSION RJ 45 TERMINATED/CERTIFIED PER …

FACULTY LOUNGE 104

STOR 102AOFFICE 111TOIL 109TOFFICE 108

TOILET 103ATOILET 103B

CLASSROOM 102

CORRIDOR 112

JANITOR J70

TOILET 102T

PANTRY 107

KITCHEN 106

TOILET 101T

STOR 101

STOR 101A

CLASSROOM 101

CLASSROOM 103

PORCH 114PORCH 113

CO

RR

ID

OR

1

05

TO

IL

1

10

T

1

1

1

1IC

W

M

IC

W

M

IC

W

M

IC

M

2

1

1

9

0

°

9

0

°

9

0

°

IC

CA

9

0

°

9

0

°

9

0

°

90°90°

+108-120"+108-120"

+108-120"

+108-120"

90°90°

+108-120"+108-120"

90°

+144"

9

0

°

9

0

°

M32

3

4

5

6

7

8

9

10

11

+108" -

+120"

+108" -

+120"

+108" -

+120"

+108" -

+120"

+108" -

+120"

J

J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J

JJ

JJ

J J J J J J J J

JJ

JJ

JJ

JJ

JJ

JJ

JJ

12

13

14 14 14

15

1617

18

19

19

19

19

20

S

21

22

23

24

1

2

3

45

6

7

8

9

10

11

12

13

SITE NO.

SCALE

DATE

CHECKED BY

S.F.U.S.D. PROJECT NO.

SHEETS

DRAFTER

OF

XXXX05/31/18 JSM -

12064

CONSTRUCTION

DESIGN &

FACILITIES

135 Van Ness Avenue

San Francisco, California 94102

Tel (415) 355-6979

Fax (415) 355-6988

Architect Engineer

School Name and Address

Project Name

Date No. Revisions

SHEET NO.

DRAWING TITLE

Approvals

AS NOTED

SFUSD SAN FRANCISCOPUBLIC SCHOOLS

Consultant Name and Address

05/15/2018 - BID ISSUE

G U T T M A N N B L A E V O E T

C O N S U L T I N G E N G I N E E R S

E

P F

THERESA MAHLER

EARLY EDUCATION SCHOOL

990 CHURCH STREET

SAN FRANCISCO, CA 94114

SFUSD PROJ. #12064

SECURITY

IMPROVEMENTS

TY-2.1

CCTV AND ENTRY SYSTEM

SITE PLAN

THIS ROOM HAS ACCESSIBLE T-GRID CEILING

EXISTING RACK TO MOUNT NVR AND AIPHONE

CONTROLLER, MOVE RAILS OUT TO ACCOMMODATE

NEW EQUIPMENT DEPTH TO THAT DATA CABLES TO

NOT TOUCH FRONT DOOR.

NEW AIPHONE DOOR STATION. INSTALL WIREWAY ON

INTERIOR WALL FOR STATION AND PUNCH THRU TO

OUTSIDE STATION AT +48" FOR THIS UNIT. IF WALL CAN

BE FISHED OPEN CABLE TO ACCESSIBLE CEILING IS

PREFERRED.

TYPICAL NEW EXTERIOR CAMERA LOCATION , SEE

DETAILS

TYPICAL NEW AIPHONE MASTER STATION ON WALL AT

+48" AFF, FISH WIRE IN WALL OR ROUTE SURFACE

WIREMOLD TO STATION AT HIS LOCATION,

COORDINATE FINAL LOCATION WITH SITE STAFF

PRINCIPAL

NEW MASTER STATOIN ON WALL IN CLASSROOM BY

DOOR, WALL MOUNTED UNIT

NEW SECURITY MONITOR IN PASSABLE WAY, MOUNT

AT +1-8" ON SWING ARM OUT MOUNTING BRACKET AT

THIS LOCATION. EXTEND 120VAC POWER FROM

NEAREST OUTLET AT THIS LOCATION USING

WIREMOLD 500 OR 700 TO MATCH WALL COLOR AND

LOCATE BEHIND MONITOR FOR DUPLEX BOX

1

2

3

4

5

KEYED NOTES:

6

7

ROUTE NEW CABLES INTO EQUIPMENT RACK,

FOLLOWING SAME PATHWAYS INTO CABINET, MOUNT

UPS IN BOTTOM OF CABINET AND MOVE OTHER

NETWORK EQUIPMENT TO TOP AS NEEDED TO

FACILITATE INSTALLATION OF NEW SECURITY

EQUIPMENT, USE EXISTING POWER AT THIS LOCATION

NEW MASTER STATION ON WALL BY PHONE

COORDINATE FINAL LOCATION WITH SITE PRINCIPALS

AT THIS LOCATION, WALL MOUNTED UNIT.

NEW CAMERA MOUNTED ON FACIA OF OVERHANG SO

THAT IT LOOKS AT THE HIGH PLAY YARD AREA.

NEW CAMERA ON BUILDING LOOKING AT PLAY AREA

TYPICAL NEW

3

4

" CONDUIT ON BEAM AND SUPPORT OF

OVERHANG

NEW TRUNK CONDUIT ALONG BUILDING, TYPICALLY

3

4

"

AT THIS LOCATION

NEW TRUNK CONDUIT AT THIS LOCATION ALONG

BUILDING SIZE FOR CABLE COUNT - MINIMUM 1"

CONDUIT

NEW NEMA 3R BOX RECOMMEND 12 X 12 X 4 AT THIS

LOCATION ON BLDG AT +108-120"

NEW 2" CONDUIT FROM JUNCTION STUBBED INTO

ACCESSIBLE CEILING SPACE OF FACULTY LOUNGE

8

9

10

11

12

13

14

15

16

BUSH END OF CONDUIT STUB INTO BLDG.

NEW 2" CONDUIT FROM JUNCTION STUBBED INTO

ACCESSIBLE CEILING SPACE OF FACULTY LOUNGE

NEW J-HOOKS FOR AIPHONE CABLING THROUGH

BLDG.

NEW WALL MOUNTED MASTER STATION, FISH WALL AS

POSSIBLE, OR USE EXISTING DROP PATHWAYS TO

ESTABLISH NEW STATION FOR THE SECRETARIES

LOCATIONS

NEW SURFACE MOUNTED ELECTRIC STRIKE AT THIS

LOCATION , MOUNT TO VERTICAL COLUMN TRANSITION

FROM CONDUIT TO W/P BOX AND ARMORED CABLE TO

SERVICE.

NEW

3

4

" CONDUIT STUBBED INTO CEILING SPACE FOR

STRIKE CABLING.

STUB INTO ACCESSIBLE CEILING SPACE WITH

3

4

"

CONDUIT AND CONTINUE CABLE TO RACK FOR POWER,

INSTALL DOOR POWER SUPPLY BELOW RACK

INSTALL DOOR POWER SUPPLY ON WALL BELOW RACK

AN CONNECT TO POWER IN RACK

17

18

19

20

ALTERNATE WIRING APPROACH CAN USE J-HOOKS AND

ROUTE CCTV CAMERA AND POWER CABLES VIA CONDUIT

STUBS TO CAMERAS EXTERIOR TO BLDG. IN LIEU OF

CONDUIT AROUND THE BLDG., HOWEVER ADDITIONAL

HAZMAT COORDINATION SHALL BE REQUIRED FOR DRILLING

THROUGH STRUCTURE

21

22

23

24

ALL NEW CONDUITS, WIREWAYS, ETC. SHALL

BE PAINTED TO MATCH. USE COLOR

MATCHING TECHNOLOGY OR GET PAINT

NUMBERS FROM SFUSD BUILDINGS AND

GROUNDS DEPT.

AutoCAD SHX Text
2351 Powell Street
AutoCAD SHX Text
&
AutoCAD SHX Text
415 655 4000 415 655 4001
AutoCAD SHX Text
San Francisco, CA. 94133-1449
AutoCAD SHX Text
Page 5: AT EARLY EDUCATION SCHOOL 990 CHURCH … · conduit fill is the sole responsibility of the ... CAT 6. CABLE FOR SECURITY CAMERA VIDEO TRANSMISSION RJ 45 TERMINATED/CERTIFIED PER …

TY5.1

SECURITY SYSTEM BLOCK

RISER DIAGRAM AND

CAMERA MATRIX

PWR

TO UPS

120VAC

CCTV CAMERA SURVEILLANCE RISER BLOCK DIAGRAM - MISSION SITE

SCALE: NONE-

1

PATCH PNL

NVR

POWER SUP.

93 4

LEVEL 1 / GROUND FLOOR

D, P1 (TYPICAL)

1 2 6 7 85

(N) (N) (N)(N)(N)(N)(N)(N)

SITE NO.

SCALE

DATECHECKED BY

S.F.U.S.D. PROJECT NO.

SHEETS

DRAFTER

OF

XXXX05/31/18 JSM -

12064

CONSTRUCTION

DESIGN &

FACILITIES

135 Van Ness Avenue

San Francisco, California 94102

Tel (415) 355-6979

Fax (415) 355-6988

Architect Engineer

School Name and Address

Project Name

Date No. Revisions

SHEET NO.

DRAWING TITLE

Approvals

AS NOTED

SFUSD SAN FRANCISCOPUBLIC SCHOOLS

Consultant Name and Address

05/15/2018 - BID ISSUE

G U T T M A N N B L A E V O E T

C O N S U L T I N G E N G I N E E R S

E

P F

THERESA MAHLER

EARLY EDUCATION SCHOOL

990 CHURCH STREET

SAN FRANCISCO, CA 94114

SFUSD PROJ. #12064

SECURITY

IMPROVEMENTS

(N)

M32

V2

MAIN OFFICE

TO DISTRICT

NETWORK SWITCH

WAN/LAN

PATCH

CAMERA RES. TYPE NEW OREXISTING SIGNAL CABLE POWER CABLE PATCH PANEL

PORT DVR PORT

1 1080HD FIXED (N) (N) (N) 1 DVR-1-1

2 1080HD FIXED (N) (N) (N) 2 DVR-1-2

3 1080HD FIXED (N) (N) (N) 3 DVR-1-3

4 1080HD FIXED (N) (N) (N) 4 DVR-1-4

5 1080HD FIXED (N) (N) (N) 5 DVR-1-5

6 1080HD FIXED (N) (N) (N) 6 DVR-1-6

7 1080HD FIXED (N) (N) (N) 7 DVR-1-7

8 1080HD FIXED (N) (N) (N) 8 DVR-1-8

9 1080HD FIXED (N) (N) (N) 9 DVR-1-9

CCTV CAMERA SURVEILLANCE MATRIX - MISSION SITE

SCALE: NONE-

2

10 DVR-1-10

11 DVR-1-1112 DVR-1-12

13 DVR-1-1314 DVR-1-14

15 DVR-1-15

16 DVR-1-16

1110

(N)(N)(N)(N)

12 13

10 1080HD FIXED (N) (N) (N)

11 1080HD FIXED (N) (N) (N)

12 1080HD FIXED (N) (N) (N)

13 1080HD FIXED (N) (N) (N)

SPARESPARESPARE

AutoCAD SHX Text
2351 Powell Street
AutoCAD SHX Text
&
AutoCAD SHX Text
415 655 4000 415 655 4001
AutoCAD SHX Text
San Francisco, CA. 94133-1449
AutoCAD SHX Text
Page 6: AT EARLY EDUCATION SCHOOL 990 CHURCH … · conduit fill is the sole responsibility of the ... CAT 6. CABLE FOR SECURITY CAMERA VIDEO TRANSMISSION RJ 45 TERMINATED/CERTIFIED PER …

SECURITY DETAILS

TY-7.1

NOTE: ALL CONDUIT SHALL BE INSTALLED UNDER BUILDING EAVES AND/OR UNDERSIDE OF WALKWAY COVERS

INSTALL TIGHT TO ALL SURFACES

TO PREVENT FINGER ACCESS

ABOVE OR BEHIND.

STEEL COMPRESSION COUPLING (EMT ONLY)

2-HOLE STRAP (TYP)

(ROUTE MULTIPLE CONDUITS WITH UNISTRUT)

OR THREADED RIGID COUPLING

CONDUIT SIZE A B

3/4" TO 1" 6" 18"

1¼" TO 2" 12" 24"

2½" TO 4" 12" 48"

(ROUTE MULTIPLE CONDUITS WITH

UNISTRUT BRACING AND SUPPORT)

PACKING

WOOL, ETC.

BACKEROD,

MINERAL

MATERIAL

FSP PUTTY

NELSON

(OPTIONAL)

METAL SLEEVE

1/2" DEPTH

BOTH SIDES

STEEL SLEEVE

OF FSP PUTTY

CAULK OVER

1" MAX

METAL PIPE

OR CONDUIT

CONCRETE WALL

(SOLID OR BLOCK)

1" FOR 3 HOURS

1/2" FOR 1-2 HOURS

System No.

C-AJ-1004

I

S

A

S

R

L

C

I

F

D

E

F Rating 3 Hr. T Rating 1/2 or 3/4 Hr.

4" MAXIMUM

FIREPROOFING CONDUIT THROUGH CONCRETE WALL

_

1

SCALE: NONE

CONDUIT STRAPPING REQUIREMENTS

_

2

SCALE: NONE

MINERAL WOOL

PACKING

BLOCK WALL

OR UL CLASSIFIED

SOLID CONCRETE

OR CONDUIT

METAL PIPE

3M FIRE BARRRIER

CP 25WB+ CALUK

DRYWALL

STUD WALL

SINGLE CHANNEL

TWO CHANNEL

MULTI-CHANNEL

MINIMUM PENETRATION:1"

SIZE & TYPE AS

REQUIRED

FIRE RATED

GYPSUM

WOOD OR STEEL STUD

WALLBOARD

1 1/2" MIN.

1/4"MAX

1/2"1/2"

FS-195 WRAP-STRIP

METAL PIPE

OR CONDUIT

3M FIRE BARRIER

System No.

W-L-1006

F Rating 2 Hr. T Rating 0 Hr.

I

S

A

S

R

L

C

I

F

D

E

2" MAXIMUM

Nelson FSP Putty - Min 1-1/2" depth

in the annular space around the pipe.

Apply an additional 1/8" crown around

the pipe where it exits the wall on

both sides.

SCALE: NONE_

4

TYPICAL CONCRETE WALL PENETRATION DETAIL

_

3

SCALE: NONE

TYPICAL WIREWAY MOUNTING DETAIL

_

5

SCALE: NONE

TYPICAL FIRE PROOFING CONDUIT THROUGH

GYP/STUD WALL

NOTE: CONDUIT STRAPPING IS REQUIRED PER DETAILS IRREGARDLESS OF WHAT ELECTRICAL CODE REQUIRES

WIREWAY OR BOX

CONDUIT SLEEVE

W/ BUSHING

FIRE CAULK &

SEAL PENETRATION

SIZE PENETRATION

TO NEC FOR 40% FILL

CEILING

1" MIN PENATRATION INTO

OR BUILDING STUD

SCALE:-

7 TYPICAL STUB FROM WIREWAY TO DEVICE BOX/BOX TO BOX

NONE

FLOOR

+48" AFF MAX.

TO OPERABLE CONTROL

SCALE:-

6 TYIPCAL STATION MOUNTING HEIGHT

NONE

SITE NO.

SCALE

DATE

CHECKED BY

S.F.U.S.D. PROJECT NO.

SHEETS

DRAFTER

OF

XXXX05/31/18 JSM -

12064

CONSTRUCTION

DESIGN &

FACILITIES

135 Van Ness Avenue

San Francisco, California 94102

Tel (415) 355-6979

Fax (415) 355-6988

Architect Engineer

School Name and Address

Project Name

Date No. Revisions

SHEET NO.

DRAWING TITLE

Approvals

AS NOTED

SFUSD SAN FRANCISCOPUBLIC SCHOOLS

Consultant Name and Address

05/15/2018 - BID ISSUE

G U T T M A N N B L A E V O E T

C O N S U L T I N G E N G I N E E R S

E

P F

THERESA MAHLER

EARLY EDUCATION SCHOOL

990 CHURCH STREET

SAN FRANCISCO, CA 94114

SFUSD PROJ. #12064

SECURITY

IMPROVEMENTS

RIGHT FACING MOUNTINGLEFT FACING MOUNTING

BACK BOX FRONT STATION FRONT STATION SIDE VIEW

SCALE:-

8 MOUNTING LOCATION FOR CALL STATION

NONE

MINERAL WOOL

PACKING

BLOCK WALL

OR UL CLASSIFIED

SOLID CONCRETE

OR CONDUIT

METAL PIPE

3M FIRE BARRRIER

CP 25WB+ CALUK

OUTLINE OF CUSTOM SHIELD

OR SHROUD FOR WEATHER

PROTECTION, VIKING ELECTRONICS

OR SIMILAR MADE FROM STAINLESS

STEEL, SIMILAR TO AIPHONE SBX-ACE

AIPHONE STATOIN

AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
A
AutoCAD SHX Text
Tested in accordance with:
AutoCAD SHX Text
ASTM E-814
AutoCAD SHX Text
ANSI/UL 1479
AutoCAD SHX Text
L
AutoCAD SHX Text
C
AutoCAD SHX Text
US
AutoCAD SHX Text
U
AutoCAD SHX Text
24" MAX
AutoCAD SHX Text
ASTM E-814
AutoCAD SHX Text
ANSI/UL 1479
AutoCAD SHX Text
Tested in accordance with:
AutoCAD SHX Text
L
AutoCAD SHX Text
C
AutoCAD SHX Text
US
AutoCAD SHX Text
U
AutoCAD SHX Text
2351 Powell Street
AutoCAD SHX Text
&
AutoCAD SHX Text
415 655 4000 415 655 4001
AutoCAD SHX Text
San Francisco, CA. 94133-1449
AutoCAD SHX Text
Page 7: AT EARLY EDUCATION SCHOOL 990 CHURCH … · conduit fill is the sole responsibility of the ... CAT 6. CABLE FOR SECURITY CAMERA VIDEO TRANSMISSION RJ 45 TERMINATED/CERTIFIED PER …

SECURITY DETAILS

TY-7.2

Front View

Side View

Top View

8-1/4”

9” 1-3/4”

3/4”

-

1

SCALESCALE:

Mounting

Screw

Lockdown

Screw

(optional)

Set Screw

Location

Mounting

Screw

-

2

SCALESCALE:

C

L

Set Screw

Location

RUN

WIRING

IN

CENTER

COLUMN

-

3

NONESCALE:

C

L

SITE NO.

SCALE

DATECHECKED BY

S.F.U.S.D. PROJECT NO.

SHEETS

DRAFTER

OF

XXXX05/31/18 JSM -

12064

CONSTRUCTION

DESIGN &

FACILITIES

135 Van Ness Avenue

San Francisco, California 94102

Tel (415) 355-6979

Fax (415) 355-6988

Architect Engineer

School Name and Address

Project Name

Date No. Revisions

SHEET NO.

DRAWING TITLE

Approvals

AS NOTED

SFUSD SAN FRANCISCOPUBLIC SCHOOLS

Consultant Name and Address

05/15/2018 - BID ISSUE

G U T T M A N N B L A E V O E T

C O N S U L T I N G E N G I N E E R S

E

P F

THERESA MAHLER

EARLY EDUCATION SCHOOL

990 CHURCH STREET

SAN FRANCISCO, CA 94114

SFUSD PROJ. #12064

SECURITY

IMPROVEMENTS

HES 9600 ELECTRIC STRIKE INSTALL DETAIL

MULLION OR CENTER COLUMN -TYPICAL

HES 9600 ELECTRIC STRIKE DIMENSIONAL

DRAWING - TYPICAL

HES 9600 ELECTRIC STRIKE INSTALL DETAIL

-TYPICAL

EXISTING CLASSROOM CONDITION NEW INSTALL CLASSROOM CONDITION

SCALE:-

4 WALL PHONE MOUTING AND RELOCATION DETAIL FOR VIDEO INTERCOM

NONE

NEW VIDEO INTERCOM

ON WALL ABOVE PHONE

NEW SHALLOW PANCAKE BOX

ON WALL FOR NEW PHONE CABLING AND OUTLET

NEW VERTICAL WIREMOLD 500 OR 700

WHITE TO CONNECT TO STATION

NEW VERTICAL WIREMOLD 500 OR 700

WHITE TO CONNECT TO STATION

NEW SHALLOW PANCAKE BOX

ON WALL FOR NEW PHONE CABLING AND

OUTLET, THIS BOX IS ONLY FOR MOUNTING

EXISTING PHONE TO MAINTAIN PROPER SPACING

FOR NEW VIDEO INTERCOM UNIT

INSTALL NEW SHALLOW BOX ON WALL AND REINSTALL

FACEPLATE AND CABLE AND RECONNECT PHONE

CAT5E

TO POWER SUPPLIES

CAT5E

MOUNTED IN NEW RACK

FLOOR

+48" AFF

#14 OR #12 CABLE 2 CONDUCTOR OVER SIZE FOR DISTANCE

TO STRIKE AND POWER SUPPLY

MAX.

SCALE:-

5 AIPHONE ENTRY SYSTEM WIRING / BLOCK DIAGRAM (PROVIDE FOR DOOR & MASTER STATIONS)

NONE

SCALE:-

6 CAMERA DROPS FOR CONDUIT AND BACKBONE ALONG BUILDING

NONE

CONDUITS ALONG BLDGCONDUITS ALONG BLDG

CONDUITS ALONG BLDGCONDUITS ALONG BLDG

CAST

W/P BOX

CAST

W/P BOX

CONDUIT TO

CAMERA

CONDUIT SWEEPS TO

DUAL CAMERAS

ALTERNATE OR OPTIONAL

CONFIGURATION ON BLDG.

AutoCAD SHX Text
2351 Powell Street
AutoCAD SHX Text
&
AutoCAD SHX Text
415 655 4000 415 655 4001
AutoCAD SHX Text
San Francisco, CA. 94133-1449
AutoCAD SHX Text
AutoCAD SHX Text
AX-DVF
AutoCAD SHX Text
AX-DVF
Page 8: AT EARLY EDUCATION SCHOOL 990 CHURCH … · conduit fill is the sole responsibility of the ... CAT 6. CABLE FOR SECURITY CAMERA VIDEO TRANSMISSION RJ 45 TERMINATED/CERTIFIED PER …

SECURITY DETAILS

TY-7.3

SITE NO.

SCALE

DATECHECKED BY

S.F.U.S.D. PROJECT NO.

SHEETS

DRAFTER

OF

XXXX05/31/18 JSM -

12064

CONSTRUCTION

DESIGN &

FACILITIES

135 Van Ness Avenue

San Francisco, California 94102

Tel (415) 355-6979

Fax (415) 355-6988

Architect Engineer

School Name and Address

Project Name

Date No. Revisions

SHEET NO.

DRAWING TITLE

Approvals

AS NOTED

SFUSD SAN FRANCISCOPUBLIC SCHOOLS

Consultant Name and Address

05/15/2018 - BID ISSUE

G U T T M A N N B L A E V O E T

C O N S U L T I N G E N G I N E E R S

E

P F

THERESA MAHLER

EARLY EDUCATION SCHOOL

990 CHURCH STREET

SAN FRANCISCO, CA 94114

SFUSD PROJ. #12064

SECURITY

IMPROVEMENTS

APPROX 8' 6" A.F.F.

EXTERIOR WALL

FINISHED SIDEWALK

INTERIOR WALL MOUNT FIXED CAMERA

SCALE: NONE-

1

APPROX 10' A.F.F.

3/4" C. TO SECURITY

PANELS/EQUIPMENT

FINISHED SIDEWALK

EXTERIOR WALL

EXTERIOR DUAL FIXED DOME DETAIL

SCALE: NONE-

2

APPROX 8' 6" ' A.F.F.

3/4" C. TO SECURITY

PANELS/EQUIPMENT

FINISHED FLOOR

INTERIOR WALL

INTERIOR DUAL FIXED DOME DETAIL - SIDE ENTRANCE

SCALE: NONE-

3

APPROX 8' 6" ' A.F.F.

3/4" C. TO

CHANNEL

FINISHED FLOOR

INTERIOR WALL

INTERIOR DUAL FIXED DOME DETAIL - TOP ENTRANCE WIREWAY

SCALE: NONE-

5

3/4" CONDUIT

OR CHASE

NIPPLE

WIREWAY CHANNEL

3/4" C. TO SECURITY

PANELS/EQUIPMENT

3/4" CONDUIT

OR CHASE

NIPPLE

APPROX 8' 6" ' A.F.F.

3/4" C.

FINISHED FLOOR

INTERIOR WALL

INTERIOR DUAL FIXED DOME DETAIL - TOP ENTRANCE

SCALE: NONE-

4

3/4" CONDUIT

OR CHASE

NIPPLE

APPROX 10' A.F.F.

EXTERIOR WALL

FINISHED SIDEWALK

EXTERIOR WALL MOUNT FIXED CAMERA

SCALE: NONE-

6

3/4" C. TO SECURITY

PANELS/EQUIPMENT

(NO FLEX ALLOWED)

AutoCAD SHX Text
2351 Powell Street
AutoCAD SHX Text
&
AutoCAD SHX Text
415 655 4000 415 655 4001
AutoCAD SHX Text
San Francisco, CA. 94133-1449
AutoCAD SHX Text