34
Assessing Single Crystal Diamond Quality Guangliang Yang Glasgow University

Assessing Single Crystal Diamond Quality Guangliang Yang Glasgow University

Embed Size (px)

Citation preview

Page 1: Assessing Single Crystal Diamond Quality Guangliang Yang Glasgow University

Assessing Single Crystal Diamond Quality

Guangliang Yang

Glasgow University

Page 2: Assessing Single Crystal Diamond Quality Guangliang Yang Glasgow University

Contents

1. Introduction

2. Experimental set up for diamond rocking curve and topography measurements.

3. Detailed Results of the diamond rocking curve and topography measurements at CHESS.

4. Conclusions.

Page 3: Assessing Single Crystal Diamond Quality Guangliang Yang Glasgow University

1. Introduction

According to the mosaic model, an imperfect crystal is believed to be composed of large number of small mosaic blocks; within each block the distribution of atoms is perfect, but for different blocks, the crystal planes have different orientations.

• The angular spread of the mosaic blocks is usually called the mosaic spread. A large mosaic spread means a poor crystal quality.

• Experimentally, we can estimate the value of the mosaic spread from the rocking curve width.

Page 4: Assessing Single Crystal Diamond Quality Guangliang Yang Glasgow University

Effects of mosaic spread on coherent bremsstrahlung

• When the diamond crystal has a large mosaic spread, there is a variation in the direction of a given reciprocal lattice vector throughout the crystal, and hence the longitudinal component of the reciprocal lattice vector ql will be slightly different for different electrons. A different ql leads to a different xd, (the upper limit of the coherent peak ) and the averaged effect is that the edge of the coherent bremsstrahlung becomes broader

Page 5: Assessing Single Crystal Diamond Quality Guangliang Yang Glasgow University

Techniques for assessing diamond crystal

• Optical polaroid analysis,

Convenient, fast, low resolution;

• X-ray topography,

High resolution, slow;

• X-ray Rocking curve,

High resolution, slow, need special equipments.

Page 6: Assessing Single Crystal Diamond Quality Guangliang Yang Glasgow University

Diamond 1532_3

Page 7: Assessing Single Crystal Diamond Quality Guangliang Yang Glasgow University

2. Experimental set up

X ray source

Asymmetric silicon 111 monochromator

Channel cut silicon 220 monochromator

Diamond sample

CCD detector

Notes: 1. The distance from the x ray source to the first monochromator is 10.1 m.

2. The distance from the first monochromator to the second one is around 2 m.

3. The distance from the first monochromator to the diamond sample is 4.4 m.

4. The distance from the diamond crystal to the CCD detectors is 0.3 m.

5. The angle between the crystal surface and the 111 reflection plane is 6 degrees for

the first monochromator.

6. At the source position, the vertical size of the x ray beam is 1.39mm (FWHM).

Page 8: Assessing Single Crystal Diamond Quality Guangliang Yang Glasgow University

Some picturesCCD detector

GoniometerDiamond

X ray beam

Page 9: Assessing Single Crystal Diamond Quality Guangliang Yang Glasgow University

3. Results.

Bad 50

Good 50

Hall b 20 microns

CCD images for three diamond radiators.

Page 10: Assessing Single Crystal Diamond Quality Guangliang Yang Glasgow University

Rocking curves measured by ion chamber (blue) and CCD camera (black).

Page 11: Assessing Single Crystal Diamond Quality Guangliang Yang Glasgow University

Rocking curves for isolated pixels

Rocking curve at radiation damaged region

The narrowest rocking curve from this measurement.

Note: The pixel size is roughly 20 microns by 20 microns

Page 12: Assessing Single Crystal Diamond Quality Guangliang Yang Glasgow University

Rocking curves measured without (bottom) and with (top) the second monochromator.

Page 13: Assessing Single Crystal Diamond Quality Guangliang Yang Glasgow University

Results for the 20 microns thick diamond

Contour map of the rocking curve width (-220 scan)

Page 14: Assessing Single Crystal Diamond Quality Guangliang Yang Glasgow University

Rocking curve peak position over the measured regions (-220 scan)

Page 15: Assessing Single Crystal Diamond Quality Guangliang Yang Glasgow University

Contour map of the rocking curve width (220 scan)

Page 16: Assessing Single Crystal Diamond Quality Guangliang Yang Glasgow University

Rocking curve peak position over the measured regions (220 scan)

Page 17: Assessing Single Crystal Diamond Quality Guangliang Yang Glasgow University

crystal shape calculated by using the rocking curve peak position of each pixel.

Page 18: Assessing Single Crystal Diamond Quality Guangliang Yang Glasgow University

Diamond rocking curves, a) measured result, b) simulated result.

Page 19: Assessing Single Crystal Diamond Quality Guangliang Yang Glasgow University

Results for the Gwurg diamond

Page 20: Assessing Single Crystal Diamond Quality Guangliang Yang Glasgow University

Rocking curve for a single pixel

Page 21: Assessing Single Crystal Diamond Quality Guangliang Yang Glasgow University

Rocking curve peak position over the measured regions (-220 scan)

Page 22: Assessing Single Crystal Diamond Quality Guangliang Yang Glasgow University

Rocking curve peak position over the measured regions (220 scan)

Page 23: Assessing Single Crystal Diamond Quality Guangliang Yang Glasgow University

Rocking curves for the whole crystal (-220) and (2,-2,0) scans

Page 24: Assessing Single Crystal Diamond Quality Guangliang Yang Glasgow University

crystal shape calculated by using the rocking curve peak position of each pixel.

Page 25: Assessing Single Crystal Diamond Quality Guangliang Yang Glasgow University

Results for diamond 1532 A1

Page 26: Assessing Single Crystal Diamond Quality Guangliang Yang Glasgow University
Page 27: Assessing Single Crystal Diamond Quality Guangliang Yang Glasgow University

Rocking curve for the whole crystal

Page 28: Assessing Single Crystal Diamond Quality Guangliang Yang Glasgow University

Rocking curve for a single pixel

Page 29: Assessing Single Crystal Diamond Quality Guangliang Yang Glasgow University

Conclusions

1. X-ray topograph and rocking curve measurements are very useful techniques for assessing diamond crystal qualities.

2. 2D map of rocking curve width and peak positions can be generated by using a pixel detector in X-ray rocking curve measurement.

3. For very thin diamond crystals, the curvature of diamond crystal plate has a big contribution to the crystal rocking curve width.

4. Further studies on crystal thinning and mounting methods are required.

Page 30: Assessing Single Crystal Diamond Quality Guangliang Yang Glasgow University

X ray source

C1 Station Summary

Source: e-s, Hard bend magnet HB5West, 6 mrad (horizonta) into C1

Source size FWHM (horizontal) = 1.486 mm, FWHM (vertical) = 1.39 mm

Distance to source: 14.5 m to center of hutch

Be windows: 0.030 inch into hutch

Cave slit sizes: 0 to 60 mm (horizontal), 0.25 to 3.0 mm (vertical)

White Beam: 1 horizontal mrad

Monochromators:Double-bounce (with high resolution 4-bounce capability or side

bounce)

Page 31: Assessing Single Crystal Diamond Quality Guangliang Yang Glasgow University

Asymmetric monochromator• Why should we us an asymmetric monochromator? Because the distance from x ray source to the diamond sample is short. It

affects the beam size and beam divergence.

• What does a asymmetric monochromator do? Expand the beam size by a factor of b. Reduce the beam divergence by a factor of b. Where b is asymmetric factor, and b=sin(θ+α)/sin(θ-α). θ is the bragg angle

of the reflection plane, α is the angle between the crystal surface and the reflection plane.

• What did we use at CHESS? A silicon 111 asymmetric monochromator. The angle between the crystal surface and the 111 plane is 6 degrees, At 15

kev, the reflection angle of silicon 111 is 7.53 degree. That makes the asymmetric factor b to be 8.5.

Page 32: Assessing Single Crystal Diamond Quality Guangliang Yang Glasgow University

Non dispersive geometry

• The relative orientation of the monochromator crystal and the diamond crystal defines if the system is dispersive or a non dispersive geometry.

Non dispersive Dispersive

• For the non dispersive setting, the contribution of wavelength spread of the beam to the sample rocking curve width which can be calculated by the following formula.

dω = (dλ/λ)*(tan(θ1)-tan(θ2)).

dλ/λ= sqrt(ωb*ωb + ωd * ωd) *cot(θ1).

• In order to reduce this effect, the monochromator must be carefully selected according to their Darwin width and the reflection angle. In the future a silicon 331 or 333 asymmetric monochromator will be used.

θ1

θ2

monochromator diamond

diamondmonochromator

Page 33: Assessing Single Crystal Diamond Quality Guangliang Yang Glasgow University

Design of an asymmetric monochromator

Page 34: Assessing Single Crystal Diamond Quality Guangliang Yang Glasgow University

Diamond 1482_2