47
Vacuum technology Aspects of flow For current, flow rate is directly proportional to potential difference and inversely proportional to resistance. I = V/R or I = 'V/R For a fluid flow, Q = (P 1 -P 2 )/R or 'P/R Using reciprocal of resistance, called conductance, we have, Q = C (P 1 -P 2 )

Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000

  • Upload
    vothuan

  • View
    217

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000

Vacuum technology

Aspects of flow

For current, flow rate is directly proportional to potential difference and inversely proportional to resistance.

I = V/R or I = 'V/R

For a fluid flow, Q = (P1-P2)/R or 'P/R

Using reciprocal of resistance, called conductance, we have, Q = C (P1-P2)

Page 2: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000

There are two kinds of flow, volumetric flow and mass flow

Volume flow rate, S = vAv – the average bulk velocity, A the cross sectional areaS = V/t, V is the volume and t is the time.Mass flow rate is S x density.G = UvA or UV/tMass flow rate is measured in units of throughput, such as torr.L/sThroughput = volume flow rate x pressureThroughput is equivalent to power.Torr.L/s o (g/cm2)cm3/s o g.cm/s o J/s o W

It works out that, 1W = 7.5 torr.L/s

Page 3: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000
Page 4: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000

Types of low1. Laminar: Occurs when the ratio of mass flow to viscosity (Reynolds number) is low for a given diameter.This happens when Reynolds number is approximately

below 2000.Q ~ P12-P22

2. Above 3000, flow becomes turbulentQ ~ (P12-P22)0.53. Choked flow occurs when there is a flow restriction

between two pressure regions. Assume an orifice and the pressure difference between the two sections, such as 2:1. Assume that the pressure in the inlet chamber is constant. The flow relation is, Q ~ P1

4. Molecular flow: When pressure reduces, MFP becomes larger than the dimensions of the duct, collisions occur between the walls of the vessel. Q~P1-P2

There are also other flows such as surface diffusion, permeation and diffusion of one gas through another.

Page 5: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000
Page 6: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000

Different kinds of flow patters

Page 7: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000

Number of molecules striking unit area from all sides,n = [3.5 x 1022 P]/(MT)0.5 per cm2 per sTo convert this to volume that strikes per unit area we need to divide by number density.S = n/N = 3640 (T/M)0.5 cm3/s . cm2

For air at RT, this gives, 3640(295/28.7) =11.6 L/s.cm2

Page 8: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000

Flow through an orificeAssume the flow through an orifice as shown below.Pressure in the top chamber is constant and it is very small or near zero below.The flow through orifice is, A x 11.6 L/s., A is the area in sq. cm.

Molecules come to the orifice from all angles, but the flowcan be represented in termsof a velocity. 11.6 L/cm2.s = 11,600 cm3/cm2.s = 116 m/s

Page 9: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000

Conductance

C = Q/(P1-P2) = pvA/'pP is the pressure, v is the velocity, A cross sectionalarea and 'p is the pressure difference.

Pumping speed

In the case of an orifice, this can be given as, S = C = Q/P as P2 is much smaller than P1.

For constant pumping speed, S = Vln(P1/P2)/(t1-t2)

V is the volume of the chamber, P1 and p2 are two pressure points and t1 and t2 are times at which these pressure points occurred.

Page 10: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000

How to measure pumping speed?S = Q/P-Po, P is the pressure when gas is leaked and Po is the ultimate pressure.

Page 11: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000

Pumps

There is no single pump for UHV technology. Various pumps are used to take the system from atmosphere to UHV

Page 12: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000

Time for pumping

This is a difficult parameter to calculate or predict in view ofseveral aspects such as out gassing (virtual leak). When one disregards outgassing, -Vdp/dt = SpT = (V/S)ln(Po/Pf)

This is valid only in the high pressure region, above 10 torrand above this rage many factors, such as permeation, outgassing, etc. become important.

Page 13: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000

Typical vacuum system

Page 14: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000

Virtual leaks

There are several possibilities of such leaks in every vacuum system.

An example,

Page 15: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000

Typical vacuum system and process of evacuation

Page 16: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000

Process of evacuation

Initial pumping Crossover region

Page 17: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000

Coarse vacuum pumps

Rotary pumpsMechanical diagrams

Page 18: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000

Double stage pump

Page 19: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000

Pumping speed

Page 20: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000

Diffusion (vapour jet) pumps

Page 21: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000

Vapour streams

Page 22: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000

Diffstack pump

Page 23: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000

Variation of pumping speed

Page 24: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000

UHV Chamber

Page 25: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000
Page 26: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000
Page 27: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000

Back streaming

Page 28: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000

Turbomolecular Pumps

Page 29: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000
Page 30: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000
Page 31: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000
Page 32: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000
Page 33: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000

Why a turbo is better?

Page 34: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000

Cryo Pumps

Page 35: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000

Getter Pumps

Page 36: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000

Ion Pumps

Page 37: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000

UHV Instrumentation

Flanges

Page 38: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000

Valves

Page 39: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000

UHV fittings

Feedthroughs, view ports, gas admittance valves

Page 40: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000

Pressure measurement, mechanical

Page 41: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000

Capacitance

Page 42: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000
Page 43: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000
Page 44: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000
Page 45: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000
Page 46: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000
Page 47: Aspects of flow For current, flow rate is directly ...mmrc.caltech.edu/XPS Info/Electron Spectroscopies 2007/L5 Vacuum... · This happens when Reynolds number is approximately 2000

A chamber contains all these, in addition to your experiment!