ASHRAE Insulation Standards · According ASHRAE Insulation Standards R40 R35 R30 R25 R20 R15 R10 R5 0 New ASHRAE R-Value Code ASHRAE 90.1 2004 ASHRAE 90.1 2007 ASHRAE 189.1 ASHRAE

Embed Size (px)

Citation preview

Page 1: ASHRAE Insulation Standards · According ASHRAE Insulation Standards R40 R35 R30 R25 R20 R15 R10 R5 0 New ASHRAE R-Value Code ASHRAE 90.1 2004 ASHRAE 90.1 2007 ASHRAE 189.1 ASHRAE

According

ASHRAE Insulation Standards

R40

R35

R30

R25

R20

R15

R10

R5

0

ASHRAE 90.1 2004 ASHRAE 90.1 2007 ASHRAE 189.1 ASHRAE 90.1 2010 New ASHRAE R-Value Code(The American Society of Heating,Refrigerating and Air-ConditioningEngineers) are being adoptedthroughout the country.Accordingly we thought it might behelpful to recap the code.Currently there are three ASHRAE90.1 Standards in play. ASHRAE90.1 is the nation’s model standardfor establishing energy performancerequirements of the buildingenvelope and system requirementsfor commercial buildings, residentialbuildings higher than three stories,and semi-conditioned buildings.

ASHRAE 90.1 - 2004 Many states still recognize and useASHRAE Standard 90.1-2004 whichhas been the energy code referencedin the International Building Code(IBC) and the International EnergyConservation Code (IECC).

ASHRAE 90.1 - 2007 In 2007, for the first time in over19 years, ASHRAE increased theminimum required prescriptive R-value for roof and wall insulationlevels in Standard 90.1.

The above-deck roof insulation requirements - previously at R-15 - went to R-20, an increase of33%, in every climate zone in the U.S. except 1. Similar increases were approved for walls. Theincreased roof and wall insulation values apply to all commercial and high-rise residential buildingscovered by Standard 90.1. These changes now become a part of the newest edition of the Standard –90.1-2007. The International Energy Conservation Code incorporates the ASHRAE 90.1-2007 intotheir standard. The IECC is being adopted rapidly by state and local code jurisdictions across theUnited States.

ASHRAE 189.1 - 2009The newly approved ASHRAE Standard 189.1 - 2009 became the first Standard for the Design ofHigh-Performance Green Buildings Except Low-Rise Residential Buildings, providing minimumrequirements for the design of sustainable buildings to balance environmental responsibility,resource efficiency, occupant comfort and well-being, and community sensitivity. ASHRAEStandard 189 uses the U.S. Green Building Council’s LEED Green Building Rating System as a keyresource offering a baseline that will drive green building into mainstream building practices.

ASHRAE 90.1 – 2010The next standard of code compliance will be ASHRAE 90.1 - 2010. The requirements forcommercial roofs with polyiso insulation are expected to range from R-20 in the southeast to R-35in the far north. ASHRAE has set aggressive goals for improved energy conservation in the nation’senergy performance standard for commercial buildings – targeting a 30% improvement in efficiencyfor the 2010 version of the standard.

PossibleImpacts

Higher CostRetro-fits

In many climate zones there willbe the additional cost of insulationplus the cost of curb height andedge detail changes.

MaintenanceIt seems logical that customers

investing in a new roof will want toprotect their investment so that theroof can go through a restorationphase where membrane only iseither replaced or coated

Return OnInvestment

Calculations Contractors may be asked toprovide a ROI calculationcomparing the cost of insulation toenergy savings. Contractors can useon-line calculators such as NRCA’sEnergyWise calculator or theDOE’s calculator.

New Concerns No one is exactly sure what thelateral movement of 7” ofinsulation will have on membrane.Additionally expect to see more“hail guard” type cover boards andwalkway being specified to protectinsulation. Correct fasteningpatterns will be critical to systemintegrity.

Joint Labor Management CommitteeWorking Together to Build the Best Roofs