2
RESPIROMETRY EASILY MEASURE BACTERIAL PERFORMANCE IN ACTIVATED SLUDGE ASbioscope OUR (Oxygen Uptake Rate) DO (Dissolved Oxygen) Critical Oxygen Point Temperature Settlement QUICK EASY PORTABLE RESPIROMETRY Strathkelvin Instruments

ASbioscope Strathkelvin InstrumentsBioscope critical point = 0.6 mg/l 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 Strathkelvin Instruments Rowantree Avenue Newhouse, Scotland

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ASbioscope Strathkelvin InstrumentsBioscope critical point = 0.6 mg/l 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 Strathkelvin Instruments Rowantree Avenue Newhouse, Scotland

RESPIROMETRY

EASILY MEASURE BACTERIAL PERFORMANCE IN

ACTIVATED SLUDGE

ASbioscope

▲ OUR (Oxygen Uptake Rate)

▲ DO (Dissolved Oxygen)

▲ Critical Oxygen Point

▲ Temperature

▲ Settlement

QUICK

EASY

PORTABLE

RESPIROMETRY

StrathkelvinInstruments

Page 2: ASbioscope Strathkelvin InstrumentsBioscope critical point = 0.6 mg/l 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 Strathkelvin Instruments Rowantree Avenue Newhouse, Scotland

AS Bioscope

RESPIROMETRY - WITHOUT THE LAB

WITH THE AS BIOSCOPE YOU CAN:

▲ Profile biodegradation rates by assessing how your plant is performing under real-time conditions.

▲ Compare bacterial health with the last ten measurements at a specified point.

▲ Optimize Energy by determining the critical oxygen point

▲ Measure DO and temperature levels at any selected point in your plant, including RAS lines and clarifiers.

▲ Assess SVI & sSVI performance

FEATURES

▲ MS Windows touch-screen interface

▲ Software automatically calculates

OUR and Critical Oxygen point

▲ Simple data transfer to PC

▲ Measuring point history file created

• Remotely at your PC

• In the field via touch screen

• Bar-code location ID in the field

▲ Automatic temperature

compensation

The information and the illustrations in this brochure regarding appearance, service, measure, weight, consumption, maintenance times and so forth are approximate, in no way binding and subject to change. All information is correct at the time of publication. We reserve the right to deviate in construction, design, color, as well as make changes in our delivery options.

OXYGEN UPTAKE RATE (O.U.R.)BIODEGRADATION PROFILE

CRITICAL OXYGEN POINT ANALYSISsSVI TESTS

RUN SCREEN

TECHNICAL SPECIFICATIONS

▲ Sensor: . . . . . . . . . . . . . . . . . . . Luminescent Dissolved Oxygen sensor (LDO)

▲ Data Storage: . . . . . . . . . . . . . . Bioscope Tablet/SD card or USB thumb drive

▲ Environmental: . . . . . . . . . . . . . Altitudes up to 2000m (~6560 ft.)Pollution Degree 10°C to 40°C Ambient Temperature20 to 80% RH.

▲ Safety: . . . . . . . . . . . . . . . . . . . Complies with EN61010-1

▲ Storage temperature range: . . . -20 to +60°C

▲ MC Compliance: . . . . . . . . . . . . EN50081-1 and EN50082-1

▲ Weight (dry): . . . . . . . . . . . . . . . 5kg. With carrying case 12kg

▲ Power:. . . . . . . . . . . . . . . . . . . . Three Rechargeable batteries type 18650

▲ Operating System: . . . . . . . . . . MS Windows Tablet; Dell Venue 8 Pro 5830

Oxygen concentration (mg/l)

% meanresp. rate

0 1 2 3

Bioscope critical point = 0.6 mg/l150

140

130

120

110

100

90

80

70

60

50

40

30

20

10

0

Strathkelvin InstrumentsRowantree AvenueNewhouse, Scotland ML1 5RX+44 (0) 1698 730 [email protected] - www.strathkelvin.com

StrathkelvinInstruments

Liquid Analytical Resource, LLC1701 Creek Road, Suite DWest Bend, WI 53090Phone: 262-429-1310Fax: 262-429-1313email: [email protected]