Qualified Abatement Services, Inc.
1935 McGraw Street, Detroit, MI 48208 Phone: 313/361-6003 Fax: 313/361-6143
ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former Residential Building Located At 12121 Outer Drive West, Detroit, Michigan Date: 11/13/13
Prepared by: Prepared for: Qualified Abatement Services, Inc. 1935 McGraw Street Detroit, Michigan 48208 Phone: (313) 361-6003 Fax: (313) 361-6143
Michigan Land Bank Cadillac Place 3022 West Grand Blvd. , Suite 4-600 Detroit, MI 48202
Qualified Abatement Services, Inc.
Asbestos Containing Material Report
1
Client Name: Michigan Land Bank
Project Name: Michigan Land Bank ACM Assessments
Project Number: 13-011
Project Site Address (Complete): 12121 Outer Drive West, Detroit, Michigan
Size of Building (SF): 4,500 SF
Date of Site Visit: 11/13/13
Site Contact Name: Thomas B. Ross
Site Contact Phone Number: (313) 361-6003
Asbestos Inspection Performed by: Tracy Chaalan (A31317)
Areas Not Accessible: All Interior Areas Accessed
On November 13, 2013, State of Michigan Asbestos Inspector Tracy Chaalan (A31317) from Qualified conducted a pre-demolition Asbestos Containing Material Survey of the unoccupied residential property located at 12121 Outer Drive West in Detroit, Michigan (Site). The purpose of this survey was to task an accredited asbestos inspector to complete a pre-demolition asbestos and hazardous materials survey of the site and provide recommendation options for removal and disposal prior to demolition of the building. The vacant property consists of a three story, wood brick frame multi-residential building. Inspectors entered the building through the side door. On the 1st floor there are 6 apartments, On the 2nd floor there are 7 apartments and the 3rd floor it is completely shelled. Laboratory reports are included in Appendix A. Photographs of the site are included in Appendix B.
Qualified Abatement Services, Inc.
1935 McGraw Street, Detroit, MI 48208 Phone: 313/361-6003 Fax: 313/361-6143
2
The following sections summarize Qualified Abatement Services, Inc.’s findings:
TABLE 1 (HAZARDOUS MATERIALS INVENTORY)
Tires Back of Building 10 Paint Back of Building 1 Gallon
Air Conditioning Units In walls Outer Left Side 2 Paint Apartment 103 1 Gallon
Gas Tank Apartment 103 1 Television Apartment 103 1
Paint Hallway 1 (5 Gallon) Paint Maintenance Room 3 (5 Gallon) Paint Front Landing 1 (5 Gallon)
Fluorescent Bulbs Throughout 14 Television 2nd Floor 2
The following suspect asbestos containing materials (ACM) were determined to be asbestos containing (>1%):
TABLE 2 (ASBESTOS CONTAINING MATERIALS)
Material/Item Description Location Approximate Material Quantity
ID # Material Location Approximate Quantity Result
7-EC-B Exterior Caulk Exterior of Building 800 LF
(58 Windows 2 Doors)
10% Chrysotile
Qualified Abatement Services, Inc.
1935 McGraw Street, Detroit, MI 48208 Phone: 313/361-6003 Fax: 313/361-6143
3
The following suspect ACM were sampled and found to not contain more than one percent asbestos:
TABLE 3 (NON-ACM SUSPECT MATERIAL)
NAD = No Asbestos Detected NA = Not Applicable
ID # Material Location Approximate Quantity Result
1-RMH-A,B,C Roofing Shingles House Roof in Back of Building 4,500 SF (1 Layer of Debris) NAD
2-SR-A,B,C,D, E,F,G,H, I, J Sheet Rock 1st Floor: 6 Apartments and Hall
Walls and Ceilings 19,600 SF Trace >1%
3-MLF-A,B,C Multi-Layer
Flooring (1x1 Brown)
Kitchens (2nd Floor: 7 Apartment & 1st Floor: 6 Apartments) 1,200 SF NAD
4-LS A,B,C Light Shield 1st Floor 6 SF (2 Shields) NAD
5-FT-A,B,C Floor Tile (1x1 Brown)
2nd Floor Hall: Right Middle Apartment 103 40 SF NAD
5-FT-a,b,c Floor Tile Mastic 2nd Floor Hall: Right Middle Apartment 103 40 SF NAD
6-FT-A,B,C Floor Tile (9x9 Black/White) 2nd Floor: Apartment 202 Kitchen 100 SF NAD
6-FT-a,b,c Floor Tile Mastic 2nd Floor: Apartment 202 Kitchen 100 SF NAD
8-SR-A,B,C,D, E,F,G,H, I,
J,K,L Sheet Rock 2nd Floor: 7 Apartments and Hall
Walls and Ceilings 20,400 SF NAD
Qualified Abatement Services, Inc.
1935 McGraw Street, Detroit, MI 48208 Phone: 313/361-6003 Fax: 313/361-6143
4
No other suspect ACM or Hazardous Materials were observed on the Site. Although not anticipated based on surface observations, underground structures that could contain ACM may be present and should be managed accordingly if encountered during Site redevelopment. Asbestos is a hazardous substance. Its condition, handling and disposal are regulated by federal, state, and local agencies. ACMs generally do not pose a health threat unless the asbestos fibers are disturbed, become airborne and are inhaled. Contractors working in an area where asbestos is present must be informed of the type and location of ACMs. Abatement of ACMs, including non-friable ACMs, must be performed by a Michigan licensed, certified and registered asbestos abatement contractor in accordance with state and federal Occupational Safety and Health Administration (OSHA) and local air quality management regulations. Lead-based paint may be present on the site and is a hazardous substance. Its condition, handling and disposal are regulated by federal, state, and local agencies. LBP generally does not pose a health threat unless particles are disturbed, become airborne and are inhaled or ingested. Contractors and their employers that will be disturbing the building during demolition should follow all applicable requirements in the OSHA Lead in Construction Standard. Further testing may be required of debris generated from demolition activities to determine whether the debris should be disposed as hazardous waste under the Resource Conservation and Recovery Act (RCRA) in accordance with 40-CFR Part 261 Subpart C.
RECOMMENDATIONS:
Except for the following items listed below, Section 61.145(c) of the Asbestos NESHAP requires that each owner or operator of a demolition or renovation activity involving RACM remove all such material from a facility being demolished or renovated before any activity begins that would break up, dislodge, or similarly disturb the material or preclude access to the material for subsequent removal.
ACM need not be removed before demolition if it:
(i) Is a Category I non-friable ACM that is not friable.
(ii) Is on a facility component that is encased in concrete or other similarly hard material and is adequately wet whenever exposed during demolition.
(iii) Was not accessible for testing and therefore was not discovered until after demolition began and, as a result of the demolition, cannot be safely removed. If not removed for safety reasons, the exposed RACM and any asbestos-contaminated debris must be treated as asbestos-containing waste material and kept adequately wet at all times until disposed of.
(iv) Is a Category II non-friable ACM and the probability is low that the material will become crumbled, pulverized, or reduced to powder during demolition.
Demolition with Roofing Materials in Place is covered under the NESHAP regulations (40 CFR Part 61 Subpart M).
Qualified Abatement Services, Inc.
1935 McGraw Street, Detroit, MI 48208 Phone: 313/361-6003 Fax: 313/361-6143
5
Roofing materials were generally not tested during this inspection and therefore the roofing material should be assumed to be Category I asbestos-containing roofing materials. Since demolition activities do not include sanding, grinding, cutting, or abrading, Category I asbestos-containing roofing materials not in poor condition and not friable are not considered RACM and are allowed to remain in place during demolition. If the asbestos-containing roofing material is not in poor condition and is not friable, it may be disposed of in a landfill which accepts ordinary demolition waste.
The asbestos-containing roofing material may not be ground up for recycling into other products. In addition, contractors should ensure they follow all OSHA regulations pertaining to demolition of Category I ACM materials. Category I or II nonfriable ACM that is not subject to 61.150(a)(3) would still have to be disposed of in a landfill that accepts building debris, in a landfill that operates in accordance with 61.154, or at a facility that operates in accordance with 61.155. Qualified Abatement Services, Inc. recommends:
A licensed asbestos abatement company should remove the following materials prior to demolition: 1. Asbestos containing exterior caulking should be removed within a regulated work area
demarcated with danger asbestos sign and tape. Utilizing drop cloths below work areas. Keeping materials adequately wet before, during and after removal. Asbestos waste to be placed in properly labeled danger asbestos bags or impermeable containers properly sealed, labeled and disposed as asbestos waste.
LIMITATIONS: The results, findings, conclusions, and recommendations expressed in the report are based only on conditions that were noted during Qualified Abatement Services, Inc. Asbestos Containing Material and Hazardous Materials Survey of the vacant above-referenced residential property located in Detroit, Michigan. Any conditions or materials that could not be visually identified through limited destructive sampling were not inspected and may differ from those conditions or materials noted. The user of this report should keep in mind that conditions may change with time and observations made by Qualified Abatement Services, Inc. at the time of the Site reconnaissance may not be consistent with future observations made by others. Additional materials may be encountered during the demolition process and may require further sampling to determine disposal criteria. The report is designed to aid the building owner, architect, construction manager, general contractors, and potential asbestos abatement contractors in locating asbestos building materials to be removed prior to demolition activities.
Qualified Abatement Services, Inc.
1935 McGraw Street, Detroit, MI 48208 Phone: 313/361-6003 Fax: 313/361-6143
6
Under no circumstances is the report to be utilized as a bidding document or as a project specification document. Contractors bidding the demolition of this Site should field verify project information. Qualified Abatement Services, Inc. appreciates the opportunity to be of service to The Michigan Land Bank on this project. In the meantime if you have questions regarding the information in this report or if we can be of further assistance do not hesitate to contact the undersigned at (313) 361-6003 Sincerely, QUALIFIED ABATEMENT SERVICES, INC.
Thomas B. Ross Project Manager
Attachments
Qualified Abatement Services, Inc.
1935 McGraw Street, Detroit, MI 48208 Phone: 313/361-6003 Fax: 313/361-6143
APPENDIX A
LABORATORY ANALYTICAL RESULTS AND CHAIN OF CUSTODY FORMS
Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)
Location:
Layer:
Roofing Material
Fiberglass - 30%No Asbestos Observed
NOAsbestos Present: 48880 - 01
black,fibrous,homogenous
1935 McGrawDetroit, MI 48208
Appearance:
Sample Information Asbestos Type/Percent Non-Asbestos
Cust. #: Other - 70%
Project # 13011
11/25/13
Lab ID #:
11/13/1311/20/1311/25/13
13-48880Mr. Thomas B. Ross
Date Analyzed:
Project: 12121 Outer Dr. W
1
Report To:
1of
Qualified Abatement Services
ARI Report # Date Collected: Date Received:
Date Reported:
1-RMH-A
House l layer Debris in BackMaterial:
Location:
Layer:
Location:
Layer:
House l layer Debris in BackMaterial:
of 1
Roofing Material
black,fibrous,homogenous
Roofing Material 1-RMH-C
House l layer Debris in Back
48880 - 03
Appearance:
Other - 70%Material: Cust. #:
black,fibrous,homogenous
NOAsbestos Present: Fiberglass - 30%
Appearance:
1
Lab ID #:
1
Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
For Layered Samples, each component will be analyzed and reported separately.
1of
No Asbestos Observed
Robert T. Letarte Jr., Laboratory Director
Asbestos Present: 1-RMH-B
Lab ID #: Fiberglass - 30%Cust. #:
48880 - 02No Asbestos Observed
NOOther - 70%
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 1 of 20
Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)
1935 McGrawDetroit, MI 48208
Project # 13011
11/25/13
11/13/1311/20/1311/25/13
13-48880Mr. Thomas B. Ross
Date Analyzed:
Project: 12121 Outer Dr. W
Report To:
Qualified Abatement Services
ARI Report # Date Collected: Date Received:
Date Reported:
Location:
Layer:
Lab ID #: 2-SR-1 A No Asbestos Observed
Sample Information Asbestos Type/Percent Non-Asbestos
Fiberglass - 10%48880 - 04
Cust. #:
white,fibrous,nonhomogenous
NO
lst FL 6 Apts. & HallMaterial:
Asbestos Present: Cellulose - 10%
1 of 2
Sheet Rock Other - 80%
Appearance:
Location:
Layer:
Location:
Layer:
NVLAP Lab Code 102118-0
Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
For Layered Samples, each component will be analyzed and reported separately.
1 of 2
Robert T. Letarte Jr., Laboratory Director
Material:
Appearance: white,fibrous,nonhomogenous
Sheet Rock Other - 80%
Asbestos Present: NO Cellulose - 10%
lst FL 6 Apts. & Hall
Appearance: white,fibrous,homogenousPOINT COUNT RESULT
Mudlst FL 6 Apts. & Hall
Lab ID #:
Material: Cust. #:
Asbestos Present: 2-SR-1 A48880 - 04a
Lab ID #: Cust. #:
2 of 2
48880 - 05Fiberglass - 10%No Asbestos Observed2-SR-1 B
Chrysotile - 0.75%NO Other - 99.25%
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 2 of 20
Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)
1935 McGrawDetroit, MI 48208
Project # 13011
11/25/13
11/13/1311/20/1311/25/13
13-48880Mr. Thomas B. Ross
Date Analyzed:
Project: 12121 Outer Dr. W
Report To:
Qualified Abatement Services
ARI Report # Date Collected: Date Received:
Date Reported:
Location:
Layer: 2 of 2
lst FL 6 Apts. & Hall POINT COUNT RESULTMaterial: Mud
NO
Appearance: white,fibrous,homogenous
Cust. #: 2-SR-1 B Chrysotile - 0.25%
Sample Information Asbestos Type/Percent Non-Asbestos
Other - 99.75%Lab ID #: 48880 - 05a Asbestos Present:
Location:
Layer:
Location:
Layer:
NVLAP Lab Code 102118-0
1 of 2
lst FL 6 Apts. & HallAppearance: white,fibrous,nonhomogenous
Material: Sheet Rock Other - 80%
Asbestos Present: NO Cellulose - 10%Fiberglass - 10%No Asbestos Observed
Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
Robert T. Letarte Jr., Laboratory Director
Appearance:
For Layered Samples, each component will be analyzed and reported separately.
2 of
POINT COUNT RESULT
2white,fibrous,homogenous
lst FL 6 Apts. & Hall
Chrysotile - 0.5%Material: Cust. #: 2-SR-1 C
Mud
Other - 99.5%Lab ID #: 48880 - 06a Asbestos Present: NO
Lab ID #: 48880 - 062-SR-1 CCust. #:
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 3 of 20
Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)
1935 McGrawDetroit, MI 48208
Project # 13011
11/25/13
11/13/1311/20/1311/25/13
13-48880Mr. Thomas B. Ross
Date Analyzed:
Project: 12121 Outer Dr. W
Report To:
Qualified Abatement Services
ARI Report # Date Collected: Date Received:
Date Reported:
Location:
Layer:
No Asbestos Observed Fiberglass - 10%
1
lst FL 6 Apts. & HallAppearance: white,fibrous,nonhomogenous
Cust. #: 2-SR-1 D
Sample Information Asbestos Type/Percent Non-Asbestos
Asbestos Present:
Sheet Rock Other - 80%
1 of
Material:
Lab ID #: Cellulose - 10%NO48880 - 07
Location:
Layer:
Location:
Layer: 1
NVLAP Lab Code 102118-0
Robert T. Letarte Jr., Laboratory Director
Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
For Layered Samples, each component will be analyzed and reported separately.
1 ofAppearance: white,fibrous,nonhomogenous
lst FL 6 Apts. & Hall
Cust. #: 2-SR-1 F No Asbestos Observed Fiberglass - 10%Material: Sheet Rock Other - 80%
Asbestos Present: NO Cellulose - 10%Lab ID #:
Material: Sheet Rock
Appearance: white,fibrous,nonhomogenousof 1
Other - 80%lst FL 6 Apts. & Hall
Lab ID #: 48880 - 08No Asbestos ObservedAsbestos Present: Cellulose - 10%
Fiberglass - 10%NO
48880 - 09
Cust. #: 2-SR-1 E
1
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 4 of 20
Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)
1935 McGrawDetroit, MI 48208
Project # 13011
11/25/13
11/13/1311/20/1311/25/13
13-48880Mr. Thomas B. Ross
Date Analyzed:
Project: 12121 Outer Dr. W
Report To:
Qualified Abatement Services
ARI Report # Date Collected: Date Received:
Date Reported:
Location:
Layer:
NO
Sample Information Asbestos Type/Percent Non-Asbestos
48880 - 10 Cellulose - 10%Lab ID #: Asbestos Present:
1
Sheet Rock2-SR-1 GCust. #:
Material:
1 of
No Asbestos Observed Fiberglass - 10%Other - 80%
Appearance: white,fibrous,nonhomogenouslst FL 6 Apts. & Hall
Location:
Layer:
Location:
Layer: 1 of
Robert T. Letarte Jr., Laboratory Director
Fiberglass - 10%Other - 80%
1
NVLAP Lab Code 102118-0
No Asbestos ObservedMaterial: Sheet RockCust. #: 2-SR-1 I
48880 - 11 NOLab ID #: Asbestos Present: Cellulose - 10%
Other - 80%Material: Cust. #: Fiberglass - 10%2-SR-1 H
Sheet Rock
white,fibrous,nonhomogenous11 of
NOLab ID #: 48880 - 12 Asbestos Present:
Appearance: lst FL 6 Apts. & Hall
No Asbestos Observed
Cellulose - 10%
lst FL 6 Apts. & Hall
Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
For Layered Samples, each component will be analyzed and reported separately.
Appearance: white,fibrous,nonhomogenous
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 5 of 20
Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)
1935 McGrawDetroit, MI 48208
Project # 13011
11/25/13
11/13/1311/20/1311/25/13
13-48880Mr. Thomas B. Ross
Date Analyzed:
Project: 12121 Outer Dr. W
Report To:
Qualified Abatement Services
ARI Report # Date Collected: Date Received:
Date Reported:
Location:
Layer:
Cellulose - 10%
Material: Sheet Rock Other - 80%
Sample Information Asbestos Type/Percent Non-Asbestos
Fiberglass - 10%Lab ID #: 48880 - 13 Asbestos Present: Cust. #: 2-SR-1 J No Asbestos Observed
NO
lst FL 6 Apts. & HallAppearance: white,fibrous,nonhomogenous
1 of 1
Location:
Layer:
Location:
Layer:
Other - 100%Lab ID #: 48880 - 14
brown,nonfibrous,homogenous
Asbestos Present:
Kitchens
NO
Appearance:
Cust. #: 3-MLF-A No Asbestos Observed
1
Material: Floor Tile
Lab ID #: 48880 - 14a
of 4
Asbestos Present: Cust. #: 3-MLF-A No Asbestos Observed
KitchensMaterial: Glue
of 4
NO Other - 100%
Appearance: yellow,nonfibrous,homogenous
Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
For Layered Samples, each component will be analyzed and reported separately.
2
Robert T. Letarte Jr., Laboratory Director
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 6 of 20
Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)
1935 McGrawDetroit, MI 48208
Project # 13011
11/25/13
11/13/1311/20/1311/25/13
13-48880Mr. Thomas B. Ross
Date Analyzed:
Project: 12121 Outer Dr. W
Report To:
Qualified Abatement Services
ARI Report # Date Collected: Date Received:
Date Reported:
Location:
Layer:
Sample Information Asbestos Type/Percent Non-Asbestos
Material: Floor Tile
NO Other - 100%Cust. #: Lab ID #: 48880 - 14b
3-MLF-A No Asbestos ObservedAsbestos Present:
KitchensAppearance: brown,nonfibrous,homogenous
3 of 4
Location:
Layer:
Location:
Layer:
48880 - 14c Asbestos Present: NO Other - 100%Cust. #: 3-MLF-A No Asbestos ObservedLab ID #:
4
Material: Glue
yellow,nonfibrous,homogenousKitchens
48880 - 15
of 4Appearance:
Asbestos Present: Cust. #: 3-MLF-B No Asbestos Observed
KitchensMaterial: Floor Tile
NO Other - 100%Lab ID #:
Appearance: brown,nonfibrous,homogenousof 4
Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
For Layered Samples, each component will be analyzed and reported separately.
1
Robert T. Letarte Jr., Laboratory Director
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 7 of 20
Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)
1935 McGrawDetroit, MI 48208
Project # 13011
11/25/13
11/13/1311/20/1311/25/13
13-48880Mr. Thomas B. Ross
Date Analyzed:
Project: 12121 Outer Dr. W
Report To:
Qualified Abatement Services
ARI Report # Date Collected: Date Received:
Date Reported:
Location:
Layer:
Sample Information Asbestos Type/Percent Non-Asbestos
Material: Glue
NO Other - 100%Cust. #: Lab ID #: 48880 - 15a
3-MLF-B No Asbestos ObservedAsbestos Present:
KitchensAppearance: yellow,nonfibrous,homogenous
2 of 4
Location:
Layer:
Location:
Layer:
48880 - 15b Asbestos Present: NO Other - 100%Cust. #: 3-MLF-B No Asbestos ObservedLab ID #:
3
Material: Floor Tile
brown,nonfibrous,homogenousKitchens
48880 - 15c
of 4Appearance:
Asbestos Present: Cust. #: 3-MLF-B No Asbestos Observed
KitchensMaterial: Glue
NO Other - 100%Lab ID #:
Appearance: yellow,nonfibrous,homogenousof 4
Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
For Layered Samples, each component will be analyzed and reported separately.
4
Robert T. Letarte Jr., Laboratory Director
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 8 of 20
Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)
1935 McGrawDetroit, MI 48208
Project # 13011
11/25/13
11/13/1311/20/1311/25/13
13-48880Mr. Thomas B. Ross
Date Analyzed:
Project: 12121 Outer Dr. W
Report To:
Qualified Abatement Services
ARI Report # Date Collected: Date Received:
Date Reported:
Location:
Layer:
Sample Information Asbestos Type/Percent Non-Asbestos
Material: Floor Tile
NO Other - 100%Cust. #: Lab ID #: 48880 - 16
3-MLF-C No Asbestos ObservedAsbestos Present:
KitchensAppearance: brown,nonfibrous,homogenous
1 of 4
Location:
Layer:
Location:
Layer:
48880 - 16a Asbestos Present: NO Other - 100%Cust. #: 3-MLF-C No Asbestos ObservedLab ID #:
2
Material: Glue
yellow,nonfibrous,homogenousKitchens
48880 - 16b
of 4Appearance:
Asbestos Present: Cust. #: 3-MLF-C No Asbestos Observed
KitchensMaterial: Floor Tile
NO Other - 100%Lab ID #:
Appearance: brown,nonfibrous,homogenousof 4
Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
For Layered Samples, each component will be analyzed and reported separately.
3
Robert T. Letarte Jr., Laboratory Director
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 9 of 20
Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)
1935 McGrawDetroit, MI 48208
Project # 13011
11/25/13
11/13/1311/20/1311/25/13
13-48880Mr. Thomas B. Ross
Date Analyzed:
Project: 12121 Outer Dr. W
Report To:
Qualified Abatement Services
ARI Report # Date Collected: Date Received:
Date Reported:
Location:
Layer:
Sample Information Asbestos Type/Percent Non-Asbestos
Material: Glue
NO Other - 100%Cust. #: Lab ID #: 48880 - 16c
3-MLF-C No Asbestos ObservedAsbestos Present:
KitchensAppearance: yellow,nonfibrous,homogenous
4 of 4
Location:
Layer:
Location:
Layer:
48880 - 17 Asbestos Present: NO Fiberglass - 70%Cust. #: 4-LS-A No Asbestos Observed Other - 30%Lab ID #:
1
Material: Light Shield
yellow,fibrous,nonhomogenouslst Floor
48880 - 18
of 1Appearance:
Asbestos Present: Cust. #: 4-LS-B No Asbestos Observed
lst FloorMaterial: Light Shield
NO Fiberglass - 70%Other - 30%
Lab ID #:
Appearance: yellow,fibrous,nonhomogenousof 1
Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
For Layered Samples, each component will be analyzed and reported separately.
1
Robert T. Letarte Jr., Laboratory Director
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 10 of 20
Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)
1935 McGrawDetroit, MI 48208
Project # 13011
11/25/13
11/13/1311/20/1311/25/13
13-48880Mr. Thomas B. Ross
Date Analyzed:
Project: 12121 Outer Dr. W
Report To:
Qualified Abatement Services
ARI Report # Date Collected: Date Received:
Date Reported:
Location:
Layer:
Sample Information Asbestos Type/Percent Non-Asbestos
Material: Light Shield
NO Fiberglass - 80%Cust. #: Lab ID #: 48880 - 19
4-LS-C No Asbestos ObservedAsbestos Present:
lst Floor
Other - 20%
Appearance: yellow,fibrous,nonhomogenous1 of 1
Location:
Layer:
Location:
Layer:
48880 - 20 Asbestos Present: NO Other - 100%Cust. #: 5-FT-A No Asbestos ObservedLab ID #:
1
Material: Floor Tile
brown,nonfibrous,homogenous2nd FL Right Middle Apt. Hall 103
48880 - 20a
of 2Appearance:
Asbestos Present: Cust. #: 5-FT-A No Asbestos Observed
2nd FL Right Middle Apt. Hall 103Material: Glue
NO Other - 100%Lab ID #:
Appearance: clear,nonfibrous,homogenousof 2
Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
For Layered Samples, each component will be analyzed and reported separately.
2
Robert T. Letarte Jr., Laboratory Director
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 11 of 20
Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)
1935 McGrawDetroit, MI 48208
Project # 13011
11/25/13
11/13/1311/20/1311/25/13
13-48880Mr. Thomas B. Ross
Date Analyzed:
Project: 12121 Outer Dr. W
Report To:
Qualified Abatement Services
ARI Report # Date Collected: Date Received:
Date Reported:
Location:
Layer:
Sample Information Asbestos Type/Percent Non-Asbestos
Material: Floor Tile
NO Other - 100%Cust. #: Lab ID #: 48880 - 21
5-FT-B No Asbestos ObservedAsbestos Present:
2nd FL Right Middle Apt. Hall 103Appearance: brown,nonfibrous,homogenous
1 of 2
Location:
Layer:
Location:
Layer:
48880 - 21a Asbestos Present: NO Other - 100%Cust. #: 5-FT-B No Asbestos ObservedLab ID #:
2
Material: Glue
clear,nonfibrous,homogenous2nd FL Right Middle Apt. Hall 103
48880 - 22
of 2Appearance:
Asbestos Present: Cust. #: 5-FT-C No Asbestos Observed
2nd FL Right Middle Apt. Hall 103Material: Floor Tile
NO Other - 100%Lab ID #:
Appearance: brown,nonfibrous,homogenousof 2
Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
For Layered Samples, each component will be analyzed and reported separately.
1
Robert T. Letarte Jr., Laboratory Director
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 12 of 20
Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)
1935 McGrawDetroit, MI 48208
Project # 13011
11/25/13
11/13/1311/20/1311/25/13
13-48880Mr. Thomas B. Ross
Date Analyzed:
Project: 12121 Outer Dr. W
Report To:
Qualified Abatement Services
ARI Report # Date Collected: Date Received:
Date Reported:
Location:
Layer:
Sample Information Asbestos Type/Percent Non-Asbestos
Material: Glue
NO Other - 100%Cust. #: Lab ID #: 48880 - 22a
5-FT-C No Asbestos ObservedAsbestos Present:
2nd FL Right Middle Apt. Hall 103Appearance: clear,nonfibrous,homogenous
2 of 2
Location:
Layer:
Location:
Layer:
48880 - 23 Asbestos Present: NO Other - 100%Cust. #: 6-FT-A No Asbestos ObservedLab ID #:
1
Material: Floor Tile
black,nonfibrous,homogenous2nd FL Kitchen Rt. lst Apt. 202
48880 - 23a
of 2Appearance:
Asbestos Present: Cust. #: 6-FT-A No Asbestos Observed
2nd FL Kitchen Rt. lst Apt. 202Material: Glue
NO Other - 100%Lab ID #:
Appearance: clear,nonfibrous,homogenousof 2
Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
For Layered Samples, each component will be analyzed and reported separately.
2
Robert T. Letarte Jr., Laboratory Director
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 13 of 20
Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)
1935 McGrawDetroit, MI 48208
Project # 13011
11/25/13
11/13/1311/20/1311/25/13
13-48880Mr. Thomas B. Ross
Date Analyzed:
Project: 12121 Outer Dr. W
Report To:
Qualified Abatement Services
ARI Report # Date Collected: Date Received:
Date Reported:
Location:
Layer:
Sample Information Asbestos Type/Percent Non-Asbestos
Material: Floor Tile
NO Other - 100%Cust. #: Lab ID #: 48880 - 24
6-FT-B No Asbestos ObservedAsbestos Present:
2nd FL Kitchen Rt. lst Apt. 202Appearance: white,nonfibrous,homogenous
1 of 2
Location:
Layer:
Location:
Layer:
48880 - 24a Asbestos Present: NO Other - 100%Cust. #: 6-FT-B No Asbestos ObservedLab ID #:
2
Material: Glue
clear,nonfibrous,homogenous2nd FL Kitchen Rt. lst Apt. 202
48880 - 25
of 2Appearance:
Asbestos Present: Cust. #: 6-FT-C No Asbestos Observed
2nd FL Kitchen Rt. lst Apt. 202Material: Floor Tile
NO Other - 100%Lab ID #:
Appearance: white,nonfibrous,homogenousof 2
Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
For Layered Samples, each component will be analyzed and reported separately.
1
Robert T. Letarte Jr., Laboratory Director
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 14 of 20
Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)
1935 McGrawDetroit, MI 48208
Project # 13011
11/25/13
11/13/1311/20/1311/25/13
13-48880Mr. Thomas B. Ross
Date Analyzed:
Project: 12121 Outer Dr. W
Report To:
Qualified Abatement Services
ARI Report # Date Collected: Date Received:
Date Reported:
Location:
Layer:
Sample Information Asbestos Type/Percent Non-Asbestos
Material: Glue
NO Other - 100%Cust. #: Lab ID #: 48880 - 25a
6-FT-C No Asbestos ObservedAsbestos Present:
2nd FL Kitchen Rt. lst Apt. 202Appearance: clear,nonfibrous,homogenous
2 of 2
Location:
Layer:
Location:
Layer:
48880 - 26 Asbestos Present: NO Other - 100%Cust. #: 7-EC-A No Asbestos ObservedLab ID #:
1
Material: Exterior Caulk
white,nonfibrous,homogenous58 Windows, 2 Doors
48880 - 27
of 1Appearance:
Asbestos Present: Cust. #: 7-EC-B Chrysotile - 10%
58 Windows, 2 DoorsMaterial: Exterior Caulk
YES Other - 90%Lab ID #:
Appearance: beige,fibrous,homogenousof 1
Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
For Layered Samples, each component will be analyzed and reported separately.
1
Robert T. Letarte Jr., Laboratory Director
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 15 of 20
Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)
1935 McGrawDetroit, MI 48208
Project # 13011
11/25/13
11/13/1311/20/1311/25/13
13-48880Mr. Thomas B. Ross
Date Analyzed:
Project: 12121 Outer Dr. W
Report To:
Qualified Abatement Services
ARI Report # Date Collected: Date Received:
Date Reported:
Location:
Layer:
Sample Information Asbestos Type/Percent Non-Asbestos
Material: Exterior CaulkCust. #: Lab ID #: 48880 - 28
7-EC-CAsbestos Present:
58 Windows, 2 Doors NOT ANALYZEDAppearance:
of
Location:
Layer:
Location:
Layer:
48880 - 29 Asbestos Present:
Other - 80%
NO Cellulose - 10%Cust. #: 8-SR-2 A No Asbestos Observed Fiberglass - 10%Lab ID #:
1
Material: Sheet Rock
white,fibrous,nonhomogenous7 Apts. & Hall 2nd FL
48880 - 30
of 1Appearance:
Asbestos Present: Cust. #: 8-SR-2 B No Asbestos Observed
7 Apts. & Hall 2nd FLMaterial: Sheet Rock
NO Cellulose - 10%Fiberglass - 10%
Lab ID #:
Appearance: white,fibrous,nonhomogenousof 1
Other - 80%
Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
For Layered Samples, each component will be analyzed and reported separately.
1
Robert T. Letarte Jr., Laboratory Director
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 16 of 20
Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)
1935 McGrawDetroit, MI 48208
Project # 13011
11/25/13
11/13/1311/20/1311/25/13
13-48880Mr. Thomas B. Ross
Date Analyzed:
Project: 12121 Outer Dr. W
Report To:
Qualified Abatement Services
ARI Report # Date Collected: Date Received:
Date Reported:
Location:
Layer:
Sample Information Asbestos Type/Percent Non-Asbestos
Material: Sheet Rock Other - 80%
NO Cellulose - 10%Cust. #: Lab ID #: 48880 - 31
8-SR-2 C No Asbestos ObservedAsbestos Present:
7 Apts. & Hall 2nd FL
Fiberglass - 10%
Appearance: white,fibrous,nonhomogenous1 of 1
Location:
Layer:
Location:
Layer:
48880 - 32 Asbestos Present:
Other - 80%
NO Cellulose - 10%Cust. #: 8-SR-2 D No Asbestos Observed Fiberglass - 10%Lab ID #:
1
Material: Sheet Rock
white,fibrous,nonhomogenous7 Apts. & Hall 2nd FL
48880 - 33
of 1Appearance:
Asbestos Present: Cust. #: 8-SR-2 E No Asbestos Observed
7 Apts. & Hall 2nd FLMaterial: Sheet Rock
NO Cellulose - 10%Fiberglass - 10%
Lab ID #:
Appearance: white,fibrous,nonhomogenousof 1
Other - 80%
Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
For Layered Samples, each component will be analyzed and reported separately.
1
Robert T. Letarte Jr., Laboratory Director
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 17 of 20
Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)
1935 McGrawDetroit, MI 48208
Project # 13011
11/25/13
11/13/1311/20/1311/25/13
13-48880Mr. Thomas B. Ross
Date Analyzed:
Project: 12121 Outer Dr. W
Report To:
Qualified Abatement Services
ARI Report # Date Collected: Date Received:
Date Reported:
Location:
Layer:
Sample Information Asbestos Type/Percent Non-Asbestos
Material: Sheet Rock Other - 80%
NO Cellulose - 10%Cust. #: Lab ID #: 48880 - 34
8-SR-2 F No Asbestos ObservedAsbestos Present:
7 Apts. & Hall 2nd FL
Fiberglass - 10%
Appearance: white,fibrous,nonhomogenous1 of 1
Location:
Layer:
Location:
Layer:
48880 - 35 Asbestos Present:
Other - 80%
NO Cellulose - 10%Cust. #: 8-SR-2 G No Asbestos Observed Fiberglass - 10%Lab ID #:
1
Material: Sheet Rock
white,fibrous,nonhomogenous7 Apts. & Hall 2nd FL
48880 - 36
of 1Appearance:
Asbestos Present: Cust. #: 8-SR-2 H No Asbestos Observed
7 Apts. & Hall 2nd FLMaterial: Sheet Rock
NO Cellulose - 10%Fiberglass - 10%
Lab ID #:
Appearance: white,fibrous,nonhomogenousof 1
Other - 80%
Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
For Layered Samples, each component will be analyzed and reported separately.
1
Robert T. Letarte Jr., Laboratory Director
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 18 of 20
Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)
1935 McGrawDetroit, MI 48208
Project # 13011
11/25/13
11/13/1311/20/1311/25/13
13-48880Mr. Thomas B. Ross
Date Analyzed:
Project: 12121 Outer Dr. W
Report To:
Qualified Abatement Services
ARI Report # Date Collected: Date Received:
Date Reported:
Location:
Layer:
Sample Information Asbestos Type/Percent Non-Asbestos
Material: Sheet Rock Other - 80%
NO Cellulose - 10%Cust. #: Lab ID #: 48880 - 37
8-SR-2 I No Asbestos ObservedAsbestos Present:
7 Apts. & Hall 2nd FL
Fiberglass - 10%
Appearance: white,fibrous,nonhomogenous1 of 1
Location:
Layer:
Location:
Layer:
48880 - 38 Asbestos Present:
Other - 80%
NO Cellulose - 10%Cust. #: 8-SR-2 J No Asbestos Observed Fiberglass - 10%Lab ID #:
1
Material: Sheet Rock
white,fibrous,nonhomogenous7 Apts. & Hall 2nd FL
48880 - 39
of 1Appearance:
Asbestos Present: Cust. #: 8-SR-2 K No Asbestos Observed
7 Apts. & Hall 2nd FLMaterial: Sheet Rock
NO Cellulose - 10%Fiberglass - 10%
Lab ID #:
Appearance: white,fibrous,nonhomogenousof 1
Other - 80%
Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
For Layered Samples, each component will be analyzed and reported separately.
1
Robert T. Letarte Jr., Laboratory Director
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 19 of 20
Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)
1935 McGrawDetroit, MI 48208
Project # 13011
11/25/13
11/13/1311/20/1311/25/13
13-48880Mr. Thomas B. Ross
Date Analyzed:
Project: 12121 Outer Dr. W
Report To:
Qualified Abatement Services
ARI Report # Date Collected: Date Received:
Date Reported:
Location:
Layer:
Sample Information Asbestos Type/Percent Non-Asbestos
Material: Sheet Rock Other - 80%
NO Cellulose - 10%Cust. #: Lab ID #: 48880 - 40
8-SR-2 L No Asbestos ObservedAsbestos Present:
7 Apts. & Hall 2nd FL
Fiberglass - 10%
Appearance: white,fibrous,nonhomogenous1 of 1
Location:
Layer:
Location:
Layer:
Asbestos Present: Cust. #: Lab ID #:
Material:
ofAppearance:
Asbestos Present: Cust. #: Material:
Lab ID #:
Appearance: of
Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
For Layered Samples, each component will be analyzed and reported separately.
Robert T. Letarte Jr., Laboratory Director
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 20 of 20
Qualified Abatement Services, Inc.
1935 McGraw Street, Detroit, MI 48208 Phone: 313/361-6003 Fax: 313/361-6143
APPENDIX B
SITE PHOTOGRAPHS
ASBESTOS CONTAINING MATERIAL SURVEY VACANT RESIDENTIAL PROPERTY
12121 OUTER DRIVE WEST DETROIT, MIICHIGAN
Project No. 13-011 Qualified Abatement Services, Inc.
View of the Front of 12121 Outer Drive West
View of the Side of 12121 Outer Drive West
ASBESTOS CONTAINING MATERIAL SURVEY VACANT RESIDENTIAL PROPERTY
12121 OUTER DRIVE WEST DETROIT, MIICHIGAN
Project No. 13-011 Qualified Abatement Services, Inc.
View of the Side of 12121 Outer Drive West
View of the Back of 12121 Outer Drive West
ASBESTOS CONTAINING MATERIAL SURVEY VACANT RESIDENTIAL PROPERTY
12121 OUTER DRIVE WEST DETROIT, MIICHIGAN
Project No. 13-011 Qualified Abatement Services, Inc.
View of Tires in Back of Building
View of Paint Can in the Back of Building
ASBESTOS CONTAINING MATERIAL SURVEY VACANT RESIDENTIAL PROPERTY
12121 OUTER DRIVE WEST DETROIT, MIICHIGAN
Project No. 13-011 Qualified Abatement Services, Inc.
View of Air Conditioning Unit
View of Paint, Gas Can and Televisions in Apartment #103
ASBESTOS CONTAINING MATERIAL SURVEY VACANT RESIDENTIAL PROPERTY
12121 OUTER DRIVE WEST DETROIT, MIICHIGAN
Project No. 13-011 Qualified Abatement Services, Inc.
View of Paint Can in Hallway
View of Paint Cans in Maintenance Room
ASBESTOS CONTAINING MATERIAL SURVEY VACANT RESIDENTIAL PROPERTY
12121 OUTER DRIVE WEST DETROIT, MIICHIGAN
Project No. 13-011 Qualified Abatement Services, Inc.
View of Paint Can in Front Landing
View of Fluorescent Bulb
ASBESTOS CONTAINING MATERIAL SURVEY VACANT RESIDENTIAL PROPERTY
12121 OUTER DRIVE WEST DETROIT, MIICHIGAN
Project No. 13-011 Qualified Abatement Services, Inc.
View of Television on 2nd Floor