B&R Revision Information Version 2.6.0.3009 PVI Runtime/Development 10-Okt-2008

AS2603009_RevInfoE

  • Upload
    meho

  • View
    31

  • Download
    4

Embed Size (px)

DESCRIPTION

great ............

Citation preview

  • B&R Revision Information

    Version 2.6.0.3009 PVI Runtime/Development10Okt2008

  • ContentsB&R Revision Information (10.10.2008)Version 2.6.0.3009 PVI Runtime/Development..........................................................................................................................1

    Contents......................................................................................................................................................................................................................................1Requests and problems by ID number........................................................................................................................................................................................1Requests and problems by version.............................................................................................................................................................................................2Requests and problems by product/component..........................................................................................................................................................................3

    1A4000.02 Automation Runtime........................................................................................................................................................................................3AR AR010.............................................................................................................................................................................................................3AR PP400.............................................................................................................................................................................................................3

    1A4000.02 Automation Net/PVI.........................................................................................................................................................................................3ICOMM.....................................................................................................................................................................................................................3INA2000 Line...........................................................................................................................................................................................................3INAFRM...................................................................................................................................................................................................................3PocketPC.................................................................................................................................................................................................................4PVI DataLogger.......................................................................................................................................................................................................4PVI Manager............................................................................................................................................................................................................4PVI OPC Server.......................................................................................................................................................................................................4PVI Services .NET...................................................................................................................................................................................................4PVI Setup.................................................................................................................................................................................................................5PVI Web Server.......................................................................................................................................................................................................5Security Library........................................................................................................................................................................................................5Tools PVITransfer.................................................................................................................................................................................................6Tools PVITransfer 3.01.00.0002...........................................................................................................................................................................7WinNT CAN Treiber.................................................................................................................................................................................................7

    Revision Information Version 2.6.0.3009 PVI Runtime/Development i

  • B&R Revision Information (10.10.2008)Version 2.6.0.3009 PVI Runtime/DevelopmentThe current revision information can be downloaded from the B&R Homepage download area (http://www.brautomation.com/download).

    ContentsRequests and problems by ID number Requests and problems by version Requests and problems by product/component

    Requests and problems by ID number

    ID Valuation known since planned for solved since Description

    74445 Newfunction V2.3.0.0009 V2.6.0.3101 V2.6.0.3101 Windows CE 5.0 support

    130600 Problem V2.5.2.3001 V2.5.2.3002 PviServices in Windows CE.NET

    131395 Newfunction V2.5.2.3001 V2.5.2.3002 Reading a structure's data type now possible

    131700 Problem V2.5.2.3001 V2.5.2.3002 Exception when accessing a structure array with PlcString or BOOLvariables on SG3 targets

    131720 Problem V2.5.2.3001 V2.5.2.3002 Error 12004 if accessing to variable object before the connected event131805 Problem V2.5.0.3017 V2.5.2.3002 VariableCollection Remove method doesn't work.140685 Problem V2.5.2.3056 V2.5.2.3060 Active variables no longer switched inactive after lost connection140940 Problem V2.5.2.3060 Windows CE: Connected event of CPU object not executed141000 Problem V2.5.2.3060 Exception when writing to an array element in Windows CE144330 Problem V2.5.2.3060 V2.5.2.3061 OPC Server not registered correctly144920 Problem V2.5.2.3160 V2.5.3.3101 Incorrect resolution of complete DNS name149175 Problem V2.6.0.3106 V2.6.0.3106 USB / LPT dongle request blocks communication for approx. 300 ms153295 Problem V2.5.3.3105 Problems with the Ethernet online connection via the node number (/DA=)153875 Problem V2.5.3.3105 V2.6.0.3102 V2.6.0.3102 Termination condition no longer works158920 Problem V3.0.64.SP07 V2.6.0.3102 V2.5.3.3109 USB dongle doesn't work in Windows Vista159200 Problem V2.5.3.3107 B&R CAN driver doesn't work in Windows Vista

    159250 Newfunction V2.5.3.3107 V2.6.0.3101 V2.6.0.3102New command "ARUpdateFileGenerate": Adding the sysconf to the ARupdate file

    162985 Newfunction V2.5.3.3109 V2.6.0.3101 V2.6.0.3102 I/O monitor support for SGC Targets

    163610 Problem V2.6.0.0003 V2.6.0.3101 V2.6.0.3102 "Create remote install structure" does not work without operating system file163705 Problem V2.5.3.3009 V2.6.0.3001 V2.6.0.3001 ErrorCode is not reset after a connection is broken and reestablished164075 Problem V2.5.3.3109 V2.6.0.3101 V2.6.0.3102 Variable watch: Structure components are only shown partially164325 Problem V2.5.3.3007 V2.6.0.3101 V2.6.0.3102 "WriteVariableListToPLC" command doesn't work with TIME variables164952 Problem V2.6.0.3003 V2.6.0.3004 OPC server returns no data anymore165020 Problem V2.5.3.3109 V2.6.0.3101 V2.6.0.3102 CF creation doesn't work if one has read only access to the project directory165650 Problem V2.5.3.3009 V2.6.0.3001 V2.6.0.3001 Structures can no longer be resolved correctly.

    165735 Problem V3.0.70.4 V2.6.0.3101 V2.6.0.3102 CF creation: Problems (CPU never finishes booting) with AR 2.92 for largeHW configurations166440 Problem V2.5.3.3007 V2.6.0.3106 V2.6.0.3106 When the PVI manager is active, a dongle can only be read once166575 Problem V2.6.0.3106 V2.6.0.3106 Dongle not recognized 2nd time AR010 is started

    166950 Problem V2.5.3.3109 V2.6.0.3101 V2.6.0.3102 CD creation: The file "bootrom_pp400.sys" is missing from the outputdirectory166965 Problem V2.6.0.3102 V2.6.0.3101 Connection loss when downloading project168160 Problem V2.5.3.3109 V2.6.0.3002 V2.6.0.3002 Callbacks overwrite the write buffer of structure members

    168200 Problem V2.5.3.0028.SP05[U2.90] V2.6.0.3102 V2.6.0.3102 Error during MEMCARD UPDATE169020 Problem V2.5.3.3109 V2.6.0.3102 V2.6.0.3102 Error messages when opening the PVI OPC Configurator169627 Problem V2.5.3.3109 V2.6.0.3102 V2.6.0.3102 Crash when deleting data modules

    170110 NewfunctionV2.5.3.0026.SP01[M2.90] V2.6.0.3103 V2.6.0.3103 X20CS1020 and X20CS1030: Outgoing INA connections don't work

    170490 Problem V2.5.3.3009 V2.6.0.3008 V2.6.0.3008 PviWebserver Registry keys for line DLLs missing170755 Problem V3.0.70.5 V2.6.0.3103 V2.6.0.3103 Variables not shown after repeated download171325 Problem V2.6.0.3102 V2.6.0.3103 V2.6.0.3103 In Windows Vista PVI Manager doesn't work as service.173570 Problem V2.5.3.3109 V2.6.0.3104 V2.6.0.3104 "RemoteInstallGenerate" command doesn't copy directory for USER partition

    173985 Problem V3.0.71.1 V2.6.0.3106 V2.6.0.3106 With a certain registration sequence, RF=0 results in a data event neverbeing triggered.

    174135 Newfunction V2.6.0.3103 V2.6.0.3107 V2.6.0.3107 New command: "CFService": Partitions a CF

    174307 Problem V2.6.0.3106 V2.6.0.3106 bootrom.sys delays boot by approx. 6 seconds174670 Problem V2.6.0.3002 V2.6.0.3104 V2.6.0.3104 CF images can't be restored on 64 MB Silicon Systems CF cards

    175420 Problem V2.6.0.3104 V2.6.0.3107 V2.6.0.3107 "CFGenerate" command: Path for USER partition data can not be enteredas a relative path

    176650 Problem V2.6.0.3104 V2.6.0.3107 V2.6.0.3107 CF creation: Image file can no longer be created after process is canceled176695 Problem V2.6.0.3104 V2.6.0.3107 V2.6.0.3107 Dialog box for selecting the CF appears in the background

  • 177495 Problem V2.6.0.3104 V2.6.0.3107 V2.6.0.3107 CD creation: No relative paths are entered for the command"CFRestoreFiles"

    179015 Problem V2.6.0.3106 V2.6.0.3107 V2.6.0.3107 With Windows 2000, CF can only be created once without administratorrights

    179095 Problem V2.6.0.3103 V2.6.0.3107 V2.6.0.3107 Exit code not set when error occurs

    179100 Problem V2.6.0.3103 V2.6.0.3107 V2.6.0.3007 Section numbers are not output during PVI developer setupSection numbersare not output during PVI developer setup

    179825 Problem V2.6.0.3104 V2.6.0.3109 V2.6.0.3109 / 3.01.00.0002 User mode: "Initialization..." dialog box stays on screen179840 Problem V2.6.0.3104 V2.6.0.3109 V2.6.0.3109 / 3.01.00.0002 User mode: Progress bar remains in the same place for very long time

    179845 Newfunction V2.6.0.3109 V2.6.0.3109 / 3.01.00.0002 User mode: Updates to the layout

    184495 Problem V2.6.0.3108 V2.6.0.3109 V2.6.0.3109 / 3.01.00.0002 "CFRestoreFiles" command with partition data doesn't create a BootLoaderwith PP400 CF

    185265 Problem ARSG4_2.95.2_B02.95 V2.6.0.3109 Checksum errors at download

    Requests and problems by version

    ID valuation known since planned for solvedsince Description

    153295 Problem V2.5.3.3105 Problems with the Ethernet online connection via the node number (/DA=)159200 Problem V2.5.3.3107 B&R CAN driver doesn't work in Windows Vista185265 Problem ARSG4_2.95.2_B02.95 V2.6.0.3109 Checksum errors at download131805 Problem V2.5.0.3017 V2.5.2.3002 VariableCollection Remove method doesn't work.131720 Problem V2.5.2.3001 V2.5.2.3002 Error 12004 if accessing to variable object before the connected event131700 Problem V2.5.2.3001 V2.5.2.3002 Exception when accessing a structure array with PlcString or BOOL variables on SG3targets130600 Problem V2.5.2.3001 V2.5.2.3002 PviServices in Windows CE.NET

    131395 Newfunction V2.5.2.3001 V2.5.2.3002 Reading a structure's data type now possible

    141000 Problem V2.5.2.3060 Exception when writing to an array element in Windows CE140940 Problem V2.5.2.3060 Windows CE: Connected event of CPU object not executed140685 Problem V2.5.2.3056 V2.5.2.3060 Active variables no longer switched inactive after lost connection144330 Problem V2.5.2.3060 V2.5.2.3061 OPC Server not registered correctly144920 Problem V2.5.2.3160 V2.5.3.3101 Incorrect resolution of complete DNS name158920 Problem V3.0.64.SP07 V2.6.0.3102 V2.5.3.3109 USB dongle doesn't work in Windows Vista165650 Problem V2.5.3.3009 V2.6.0.3001 V2.6.0.3001 Structures can no longer be resolved correctly.163705 Problem V2.5.3.3009 V2.6.0.3001 V2.6.0.3001 ErrorCode is not reset after a connection is broken and reestablished168160 Problem V2.5.3.3109 V2.6.0.3002 V2.6.0.3002 Callbacks overwrite the write buffer of structure members164952 Problem V2.6.0.3003 V2.6.0.3004 OPC server returns no data anymore

    179100 Problem V2.6.0.3103 V2.6.0.3107 V2.6.0.3007 Section numbers are not output during PVI developer setupSection numbers are notoutput during PVI developer setup

    170490 Problem V2.5.3.3009 V2.6.0.3008 V2.6.0.3008 PviWebserver Registry keys for line DLLs missing

    74445 Newfunction V2.3.0.0009 V2.6.0.3101 V2.6.0.3101 Windows CE 5.0 support

    166965 Problem V2.6.0.3102 V2.6.0.3101 Connection loss when downloading project164325 Problem V2.5.3.3007 V2.6.0.3101 V2.6.0.3102 "WriteVariableListToPLC" command doesn't work with TIME variables

    159250 Newfunction V2.5.3.3107 V2.6.0.3101 V2.6.0.3102 New command "ARUpdateFileGenerate": Adding the sysconf to the AR update file

    162985 Newfunction V2.5.3.3109 V2.6.0.3101 V2.6.0.3102 I/O monitor support for SGC Targets

    166950 Problem V2.5.3.3109 V2.6.0.3101 V2.6.0.3102 CD creation: The file "bootrom_pp400.sys" is missing from the output directory165020 Problem V2.5.3.3109 V2.6.0.3101 V2.6.0.3102 CF creation doesn't work if one has read only access to the project directory164075 Problem V2.5.3.3109 V2.6.0.3101 V2.6.0.3102 Variable watch: Structure components are only shown partially163610 Problem V2.6.0.0003 V2.6.0.3101 V2.6.0.3102 "Create remote install structure" does not work without operating system file

    165735 Problem V3.0.70.4 V2.6.0.3101 V2.6.0.3102 CF creation: Problems (CPU never finishes booting) with AR 2.92 for large HWconfigurations

    168200 Problem V2.5.3.0028.SP05[U2.90] V2.6.0.3102 V2.6.0.3102 Error during MEMCARD UPDATE153875 Problem V2.5.3.3105 V2.6.0.3102 V2.6.0.3102 Termination condition no longer works169627 Problem V2.5.3.3109 V2.6.0.3102 V2.6.0.3102 Crash when deleting data modules169020 Problem V2.5.3.3109 V2.6.0.3102 V2.6.0.3102 Error messages when opening the PVI OPC Configurator

    170110 NewfunctionV2.5.3.0026.SP01[M2.90] V2.6.0.3103 V2.6.0.3103 X20CS1020 and X20CS1030: Outgoing INA connections don't work

    171325 Problem V2.6.0.3102 V2.6.0.3103 V2.6.0.3103 In Windows Vista PVI Manager doesn't work as service.170755 Problem V3.0.70.5 V2.6.0.3103 V2.6.0.3103 Variables not shown after repeated download173570 Problem V2.5.3.3109 V2.6.0.3104 V2.6.0.3104 "RemoteInstallGenerate" command doesn't copy directory for USER partition174670 Problem V2.6.0.3002 V2.6.0.3104 V2.6.0.3104 CF images can't be restored on 64 MB Silicon Systems CF cards166575 Problem V2.6.0.3106 V2.6.0.3106 Dongle not recognized 2nd time AR010 is started174307 Problem V2.6.0.3106 V2.6.0.3106 bootrom.sys delays boot by approx. 6 seconds149175 Problem V2.6.0.3106 V2.6.0.3106 USB / LPT dongle request blocks communication for approx. 300 ms166440 Problem V2.5.3.3007 V2.6.0.3106 V2.6.0.3106 When the PVI manager is active, a dongle can only be read once173985 Problem V3.0.71.1 V2.6.0.3106 V2.6.0.3106 With a certain registration sequence, RF=0 results in a data event never being triggered.179095 Problem V2.6.0.3103 V2.6.0.3107 V2.6.0.3107 Exit code not set when error occurs

    Revision Information Version 2.6.0.3009 PVI Runtime/Development 2

  • 174135 Newfunction V2.6.0.3103 V2.6.0.3107 V2.6.0.3107 New command: "CFService": Partitions a CF

    177495 Problem V2.6.0.3104 V2.6.0.3107 V2.6.0.3107 CD creation: No relative paths are entered for the command "CFRestoreFiles"176695 Problem V2.6.0.3104 V2.6.0.3107 V2.6.0.3107 Dialog box for selecting the CF appears in the background176650 Problem V2.6.0.3104 V2.6.0.3107 V2.6.0.3107 CF creation: Image file can no longer be created after process is canceled

    175420 Problem V2.6.0.3104 V2.6.0.3107 V2.6.0.3107 "CFGenerate" command: Path for USER partition data can not be entered as a relativepath179015 Problem V2.6.0.3106 V2.6.0.3107 V2.6.0.3107 With Windows 2000, CF can only be created once without administrator rights

    Requests and problems by product/component1A4000.02 Automation Runtime

    AR AR010

    ID#166575 : solved problem, known since unbekannt, solved since V2.6.0.3106

    Dongle not recognized 2nd time AR010 is started

    If the PVI manager and AR010 are running on a PC at the same time, AR010 no longer recognizes the dongle. If the PVI manager is closed,the problem goes away.

    AR PP400

    ID#174307 : solved problem, known since unbekannt, solved since V2.6.0.3106

    bootrom.sys delays boot by approx. 6 seconds

    If a PLC (AR10x, PP300, PP400) is booted when the network cable is unplugged, the boot process is delayed by 5 seconds.

    1A4000.02 Automation Net/PVI

    ICOMM

    ID#168200 : solved problem, known since V2.5.3.0028.SP05 [U2.90], solved since V2.6.0.3102

    Error during MEMCARD UPDATE

    In rare cases, deleting the Memcard before creating the Memcard update causes an error.

    ID#166965 : solved problem, known since unbekannt, solved since V2.6.0.3101

    Connection loss when downloading project

    If many PVs are registered with an open watch window at the time of the download, connection losses can occur.

    ID#170110 : new function since V2.6.0.3103

    X20CS1020 and X20CS1030: Outgoing INA connections don't work

    You can't establish a connection to another device from an interface an an X20CS1020 or X20CS1030 module, because of limitations in theINA addressing string.

    ID#162985 : new function since V2.6.0.3102

    I/O monitor support for SGC Targets

    INA2000 Line

    ID#170755 : solved problem, known since V3.0.70.5, solved since V2.6.0.3103

    Variables not shown after repeated download

    ID#169627 : solved problem, known since V2.5.3.3109, solved since V2.6.0.3102

    Crash when deleting data modules

    ID#185265 : known problem since ARSG4_2.95.2_B02.95, correction planned for V2.6.0.3109

    Checksum errors at download

    INAFRM

    ID#144920 : solved problem, known since V2.5.2.3160, solved since V2.5.3.3101

    Incorrect resolution of complete DNS name

    If the complete DNS name is specified in the DAIP parameter (e.g. /DAIP=ar106_02.brautomation.co.at), it is resolved incorrectly. Only DNSnames less than 120 characters can be specified.

    ID#153295 : known problem since V2.5.3.3105

    Problems with the Ethernet online connection via the node number (/DA=)

    Revision Information Version 2.6.0.3009 PVI Runtime/Development 3

  • If two or more network cards are used on an AS/PVI computer, then an error message appears if only the node number (/DA) is used whenestablishing the connection. However, this behavior only occurs with AR SG4 I2.90 and J2.90.

    PocketPC

    ID#74445 : new function since V2.6.0.3101

    Windows CE 5.0 support

    PVI support for Windows CE 5.0 platforms (PP100, PP40/50, Windows Pocket PC)

    PVI DataLogger

    ID#153875 : solved problem, known since V2.5.3.3105, solved since V2.6.0.3102

    Termination condition no longer works

    PVI Manager

    ID#173985 : solved problem, known since V3.0.71.1, solved since V2.6.0.3106

    With a certain registration sequence, RF=0 results in a data event never being triggered.

    If a process object is only setup with EV=e and then EV=d or EV=ed is set, the data event is not triggered until the next cyclic read. WhenRF=0, no cyclic read is triggered. Now a read is always started after a change to the "ed" events.

    ID#171325 : solved problem, known since V2.6.0.3102, solved since V2.6.0.3103

    In Windows Vista PVI Manager doesn't work as service.

    In Windows Vista the PVI Manager can not be operated as a service.

    ID#166440 : solved problem, known since V2.5.3.3007, solved since V2.6.0.3106

    When the PVI manager is active, a dongle can only be read once

    Once the PVI manager is started, the dongle can only be read one more time. If you call BrSecChk.exe again, the dongle can no longer befound. The problem only occurs with the LPT1 dongle holder on the APC.A USB dongle can be read multiple times even when the PVI manager is running.

    ID#149175 : solved problem, known since unbekannt, solved since V2.6.0.3106

    USB / LPT dongle request blocks communication for approx. 300 ms

    When using a USB or LPT dongle, communication with the PLC is blocked for approximately 300 ms each minute.

    PVI OPC Server

    ID#164952 : solved problem, known since unbekannt, solved since V2.6.0.3004

    OPC server returns no data anymore

    In a configuration with multiple PVI connections (local and remote), after a short failure of one or more remote PVI connections data is nolonger received from the OPC server.

    PVI Services .NET

    ID#168160 : solved problem, known since V2.5.3.3109, solved since V2.6.0.3002

    Callbacks overwrite the write buffer of structure members

    If the write buffer of a structure is written with Var.Active=True, the write buffer is overwritten before the structure is written to the control(changing the value on the control causes callbacks).

    ID#165650 : solved problem, known since V2.5.3.3009, solved since V2.6.0.3001

    Structures can no longer be resolved correctly.

    With PviServices 2.5.3.27 (Development 2.5.3.3009), structures can no longer be resolved.

    ID#163705 : solved problem, known since V2.5.3.3009, solved since V2.6.0.3001

    ErrorCode is not reset after a connection is broken and reestablished

    After a connection is broken and reestablished, the ErrorCode property is not reset for the CPU and variable object in the connected event.

    ID#141000 : solved problem, known since unbekannt, solved since V2.5.2.3060

    Exception when writing to an array element in Windows CE

    An exception occurred in Windows CE if writing to an array element.

    ID#140940 : solved problem, known since unbekannt, solved since V2.5.2.3060

    Revision Information Version 2.6.0.3009 PVI Runtime/Development 4

  • Windows CE: Connected event of CPU object not executed

    The connected event of the CPU object is not executed on Windows CE targets.

    ID#140685 : solved problem, known since V2.5.2.3056, solved since V2.5.2.3060

    Active variables no longer switched inactive after lost connection

    A PviServices variable object can no longer be switched inactive with "var.Active = false" after a connection is lost.

    ID#131805 : solved problem, known since V2.5.0.3017, solved since V2.5.2.3002

    VariableCollection Remove method doesn't work.

    If a variable is added to a variable collection and then removed, then it's no longer possible to add the same variable again.

    ID#131720 : solved problem, known since V2.5.2.3001, solved since V2.5.2.3002

    Error 12004 if accessing to variable object before the connected event

    ID#131700 : solved problem, known since V2.5.2.3001, solved since V2.5.2.3002

    Exception when accessing a structure array with PlcString or BOOL variables on SG3 targets

    An exception could occur when accessing a structure variable that contains plcStrings and BOOL variables.

    ID#130600 : solved problem, known since V2.5.2.3001, solved since V2.5.2.3002

    PviServices in Windows CE.NET

    If PviServices are used in Windows CE, an exception may occur when generating the service object.

    ID#131395 : new function since V2.5.2.3002

    Reading a structure's data type now possible

    The StructName property can be used to determine the name of a structure. However, the variable must have been uploaded beforehand forthis.

    PVI Setup

    ID#179100 : solved problem, known since V2.6.0.3103, solved since V2.6.0.3007

    Section numbers are not output during PVI developer setupSection numbers are not output during PVI developer setup

    When setting up the PVI developer, no sections numbers are shown in the component selection list. These section numbers are needed forautoinstall mode.

    ID#179095 : solved problem, known since V2.6.0.3103, solved since V2.6.0.3107

    Exit code not set when error occurs

    When the PVI setup is opened from the command line (in autoinstall mode), the exit code is not set when the following errors occur: The PVI setup is installed in a writeprotected directory The PVI manager is running

    ID#169020 : solved problem, known since V2.5.3.3109, solved since V2.6.0.3102

    Error messages when opening the PVI OPC Configurator

    When starting the PVI OPC Configurator, error messages appeared stating that the OS9 Arcnet and MTC lines could not be loaded.

    ID#144330 : solved problem, known since V2.5.2.3060, solved since V2.5.2.3061

    OPC Server not registered correctly

    Because the OPC Server was registered incorrectly, it could not be started automatically by the client.This problem only occurred if version 2.5.2.3060 was installed on a new PC. When updating, the OPC Server was correctly registered.

    PVI Web Server

    ID#170490 : solved problem, known since V2.5.3.3009, solved since V2.6.0.3008

    PviWebserver Registry keys for line DLLs missing

    If the setup is run on a computer that has never had an older PVI setup installed, the B&R PVI webserver can't be used, because it can't findthe corresponding registry keys for the line DLL.

    Security Library

    ID#158920 : solved problem, known since V3.0.64.SP07, solved since V2.5.3.3109

    USB dongle doesn't work in Windows Vista

    Revision Information Version 2.6.0.3009 PVI Runtime/Development 5

  • Tools PVITransfer

    ID#179015 : solved problem, known since V2.6.0.3106, solved since V2.6.0.3107

    With Windows 2000, CF can only be created once without administrator rights

    If a CF is created in Windows 2000 without administrator rights, on some PCs this process can't be repeated. During the second attempt no CFis displayed, so the process no longer works.The PC must be restarted in order for a second CF to be generated. This problem does not occur when the user has administrator rights.

    ID#177495 : solved problem, known since V2.6.0.3104, solved since V2.6.0.3107

    CD creation: No relative paths are entered for the command "CFRestoreFiles"

    If a CD is created from a .pil file that contains the "CFRestoreFiles" command, it will not work. The problem is that the paths are not entered asrelative paths for the "CFRestoreFiles" command.

    ID#176695 : solved problem, known since V2.6.0.3104, solved since V2.6.0.3107

    Dialog box for selecting the CF appears in the background

    If a CF is created automatically using the .pil file, under certain circumstances the dialog for selecting the CF appears in the background.

    ID#176650 : solved problem, known since V2.6.0.3104, solved since V2.6.0.3107

    CF creation: Image file can no longer be created after process is canceled

    If the process is cancelled while creating an image file, an image file can then no longer be created. The dialog window must be closed andreopened before an image can be created again.

    ID#175420 : solved problem, known since V2.6.0.3104, solved since V2.6.0.3107

    "CFGenerate" command: Path for USER partition data can not be entered as a relative path

    For the CFGenerate command, if the path for the USER partition data is entered as a relative path, even though it is correct it will result in anerror message stating that the directory does not exist.

    ID#174670 : solved problem, known since V2.6.0.3002, solved since V2.6.0.3104

    CF images can't be restored on 64 MB Silicon Systems CF cards

    If an image is created from a 64 MB SanDisk or Silicon Systems CF card, the image file can be restored, but the resulting CF card doesn'twork. The respective target system (e.g. PP400) can't be started with this CF card.This problem only occurs when the image is restored on a 64 MB card from Silicon Systems. If the image is restored on a 64 MB card fromSanDisk, the error doesn't occur.

    ID#173570 : solved problem, known since V2.5.3.3109, solved since V2.6.0.3104

    "RemoteInstallGenerate" command doesn't copy directory for USER partition

    If a directory is specified for the USER partition, it is not copied when generating the remote install structure.

    ID#166950 : solved problem, known since V2.5.3.3109, solved since V2.6.0.3102

    CD creation: The file "bootrom_pp400.sys" is missing from the output directory

    When a CD is created from a PP300/PP400 project, the file "bootrom_pp400.sys" is missing from the created directory. As a result, the CDthat is created cannot be used to setup a CompactFlash card for a PP300/PP400 device.

    Workaround:The file "bootrom_pp400.sys" must be manually copied from the PVI Transfer installation folder to the output directory.

    ID#165735 : solved problem, known since V3.0.70.4, solved since V2.6.0.3102

    CF creation: Problems (CPU never finishes booting) with AR 2.92 for large HW configurations

    When the PVI Transfer Tool is used to create a CF for AR 2.92 (or higher), and the HW configuration is large, the CPU gets stuck in the bootprocedure and never finishes. The reason for this is that the default setting for the SYSTEM partition of the PVI Transfer Tool is too small.

    Workaround:The size of the SYSTEM partition must be increased manually before creating the CF.

    ID#165020 : solved problem, known since V2.5.3.3109, solved since V2.6.0.3102

    CF creation doesn't work if one has read only access to the project directory

    When the user only has read only access to the project from which a CF should be created, the CF creation is completed without errors, butthe resulting CF is empty.The problem occurs, for example, when a user tries to create a CF from a project that is stored on a network (where he or she has read onlyrights). The CF is created without errors, but is empty.

    ID#164325 : solved problem, known since V2.5.3.3007, solved since V2.6.0.3102

    "WriteVariableListToPLC" command doesn't work with TIME variables

    Revision Information Version 2.6.0.3009 PVI Runtime/Development 6

  • If the command "WriteVariableListToPLC" is used to write a TIME variable to the PLC, the TIME value does not reach the PLC correctly. If,however, the function "WriteVariable" is used, everything works fine.

    ID#164075 : solved problem, known since V2.5.3.3109, solved since V2.6.0.3102

    Variable watch: Structure components are only shown partially

    If the command "VariableWatch" is used to monitor multiple structure components from the same structure, only the first structure componentis ever shown, all others are not.

    ID#163610 : solved problem, known since V2.6.0.0003, solved since V2.6.0.3102

    "Create remote install structure" does not work without operating system file

    If you select the option "Installation/Update of Automation Runtime" and begin the process of creating a remote install structure without havinga valid .pil file, the PVI Transfer Tool will crash.

    ID#174135 : new function since V2.6.0.3107

    New command: "CFService": Partitions a CF

    The new "CFService" command can be used to partition a CF card without copying data to it.

    ID#159250 : new function since V2.6.0.3102

    New command "ARUpdateFileGenerate": Adding the sysconf to the AR update file

    The "ARUpdateFileGenerate" command is used to generate an AR update file (.br) from an AR base file (.s*). The AR update file can then betransferred directly to the PLC, where it updates Automation Runtime. You can also add .br modules such as sysconf.br to the AR update file.

    Tools PVITransfer 3.01.00.0002

    ID#184495 : solved problem, known since V2.6.0.3108, solved since V2.6.0.3109

    "CFRestoreFiles" command with partition data doesn't create a BootLoader with PP400 CF

    If the command "CFRestoreFiles" is used to generate a CF with partition data for a PP400, the PP400 doesn't boot. On the PP400 you get themessage "No boot device present. Halting".

    ID#179840 : solved problem, known since V2.6.0.3104, solved since V2.6.0.3109

    User mode: Progress bar remains in the same place for very long time

    If multiple commands are called in sequence in user mode (using "include" command), the progress bar stops moving for a long time. Thisproblem occurs when a command is used that takes a long time (e.g. CFRestore). For the user, it appears that the process has frozen.

    ID#179825 : solved problem, known since V2.6.0.3104, solved since V2.6.0.3109

    User mode: "Initialization..." dialog box stays on screen

    In user mode, the "Initialization" output stays in the middle of the screen throughout the initialization phase. During long initialization phasesthis dialog box is usually in the way, and the process cannot be stopped during this time.

    ID#179845 : new function since V2.6.0.3109

    User mode: Updates to the layout

    The following changes were made to user mode: In order to display the progress better, there are now 2 progress bars (current command and total progress) New command "CustomModeSettings": This command makes it possible to turn the online status on/off (connection status and PLCinformation) during runtime.

    WinNT CAN Treiber

    ID#159200 : known problem since V2.5.3.3107

    B&R CAN driver doesn't work in Windows Vista

    The B&R CAN driver does not work in Windows Vista, and so INA 2000 via CAN and CAN direct cannot be used in Windows Vista either.

    Revision Information Version 2.6.0.3009 PVI Runtime/Development 7

    ContentsB&R Revision Information (10.10.2008)Version 2.6.0.3009 PVI Runtime/DevelopmentContentsRequests and problems by ID numberRequests and problems by versionRequests and problems by product/component1A4000.02 Automation RuntimeAR - AR010AR - PP400

    1A4000.02 Automation Net/PVIICOMMINA2000 LineINAFRMPocketPCPVI DataLoggerPVI ManagerPVI OPC ServerPVI Services .NETPVI SetupPVI Web ServerSecurity LibraryTools - PVITransferTools - PVITransfer 3.01.00.0002WinNT CAN Treiber