S O U T H K E N S I N G T O N S T A T I O N
A R O U N D S T A T I O N D E V E L O P M E N T
P RESEN TAT IO N TO CONS ULTAT I VE WORKI NG GRO UP - NO. 2
2 0 T H A P R I L 2 0 1 6
BuckleyGrayYeoman
Show our understanding of the station’s heritage -
should be the focus of the design development
Provide clarity on options being considered for Thurloe Street
Consider the massing and mix for Pelham Street
What are the proposals for the shopfronts?
What you said last time
When we presented in December.. .
B u c k l e y G r a y Y e o m a n 1
Key Moves:
3 main elements of the proposals
Understanding the Heritage:
The Arcade,
Bui lding Fabric &
Retai l Shopfronts
OUR APPROACH
B u c k l e y G r a y Y e o m a n 2
20-34 Thurloe Street
The Bullnose & Arcade
Pelham Street Opportunities
KEY MOVES
3B u c k l e y G r a y Y e o m a n
Varied scale and massing - generally 3
& 4 storeys, up to 8 storeys
Mainly residential with retail further
along Pelham Street
Mixed material palette - brick,
stonework, some render, tiled mansards
Wide footpath adjacent site - generally
3m (varies) - reduces further to east
Pelham Street
Existing context
4
Historic precedent for development on
Pelham Street
Demolished in 1970s
The first Laura Ashley store in London
was located here
Historic context
©TfL from Royal Borough of Kensington & Chelsea
©TfL from the London Transport Museum Collection
©TfL from Royal Borough of Kensington & Chelsea
5
Precedent
First thoughts
Taking our hints from.....
The local context
Good examples of new-build heritage
residential and retail
Sloane Street
Walton Street
Kings Road
Spitalfields Market
Store Street
6
Options considered
1 Storey Retail
& Basement
2 Storeys
Residential above
1 Storey Retail
3 Storeys (1 set-back)
Residential above
Townhouses
3 Storeys
Residential
- - - - - - - - - Options not pursued ---- - - - -
B u c k l e y G r a y Y e o m a n 7
G
D i s u s e d p l a t f o r m
P e l h a m S t r e e t
1 s t
2 n d
3 r d
S i t e b o u n d a r y
G
1
2
3
Section looking west
Elevation
South Kensington ASD
TFL
DRAWING NOTES:
Drawing Title
000 Drawing NameSCALE
DATE
DRAWING
DWG No. REVISION
Information contained on this drawing is the sole copyright ofBuckley Gray Yeoman and is not to be reproduced without their permission.
DRAWING FILE REF
DRAWN BYXX
Elevation BB_Existing_Proposed
(0:000 @ A3)
Mon. 20XX
DRAWING STATUSConstraints Drawing
PROJECT
CLIENT
REVISION DATE
Studio 4.04 The Tea Building 56 Shoreditch High StreetLondon E1 6JJ T: 020 7033 9913 F: 020 7033 9914
STATUS
X0
0:000 @ A1
All dimensions to be checked on site prior to commencement of any works, and/or preparation of any shop drawings.
Sizes of and dimensions to any structural elements are indicative only. See structural engineers drawings for actual sizes/dimensions.
Sizes of and dimensions to any service elements are indicative only. See service engineers drawings for actual sizes and dimensions.
This drawing to be read in conjunction with all other Architect's drawings, specifications and other Consultants' information.
All proprietary systems shown on this drawing are to be installed strictly in accordance with the Manufacturers/Suppliers recommended details.
Any discrepancies between information shown on this drawing and any other contract information or manufacturers/suppliers recommendations is to be brought to the attention of the Architect.
DO NOT SCALE FROM THIS DRAWING.
DRAWING NOTES:
0 5 10 M
KENSINGTONSOUTH STATION
Our Approach
Proposed section
Retail at ground floor
Residential apartments above:
2 levels plus further setback level
Height relates to opposite townhouses
along Pelham Street
South facing terraces
0 5 10 M
South Kensington ASD
TFL
DRAWING NOTES: Site Plan - Pelham Proposal Ground Floor Level
-SCALE
DATE
DRAWING
DWG No. REVISION
Information contained on this drawing is the sole copyright ofBuckley Gray Yeoman and is not to be reproduced without their permission.
DRAWING FILE REF
DRAWN BYBGY
816_SK-215
(1:500 @ A3)
Mar 2016
DRAWING STATUSSKETCH
PROJECT
CLIENT
REVISION DATE
Studio 4.04 The Tea Building 56 Shoreditch High StreetLondon E1 6JJ T: 020 7033 9913 F: 020 7033 9914
STATUS
-
1:250 @ A1
All dimensions to be checked on site prior to commencement of any works, and/or preparation of any shop drawings.
Sizes of and dimensions to any structural elements are indicative only. See structural engineers drawings for actual sizes/dimensions.
Sizes of and dimensions to any service elements are indicative only. See service engineers drawings for actual sizes and dimensions.
This drawing to be read in conjunction with all other Architect's drawings, specifications and other Consultants' information.
All proprietary systems shown on this drawing are to be installed strictly in accordance with the Manufacturers/Suppliers recommended details.
Any discrepancies between information shown on this drawing and any other contract information or manufacturers/suppliers recommendations is to be brought to the attention of the Architect.
DO NOT SCALE FROM THIS DRAWING.
DRAWING NOTES:
8
Massing approach
B u c k l e y G r a y Y e o m a n 9
Our Approach
20-34 Thurloe Street
Pelham Street Opportunities
The Bullnose & Arcade
10B u c k l e y G r a y Y e o m a n
The existing building
The exterior
Good example of well detailed 19th century
4 storey building. Prominent facade on to
Thurloe Street
Rear of the building has had various
alterations over the years
Separate residential and retail entrances at
ground floor level
11
Retail at ground floor (plus basement)
Mix of residential and commercial units to
upper floors of varying size and quality
Large front rooms with full height windows
overlooking Thurloe Street
Mix of dual aspect and single aspect units
The interior
The existing building
12
Retain the existing building and refurbish
Light touch refurbishment
1
B u c k l e y G r a y Y e o m a n 13
Existing facades and building structure &
fabric retained
Good floor to ceiling heights fronting Thurloe
Street
BUT
Low ceiling heights to rear above first floor
Stepped levels to rear - new lifts not viable
No level access from the street to retail and
residential units - limitation with retained
existing floor levels
South Kensington ASD
TFL
DRAWING NOTES:
Existing Section AA
000 Drawing NameSCALE
DATE
DRAWING
DWG No. REVISION
Information contained on this drawing is the sole copyright ofBuckley Gray Yeoman and is not to be reproduced without their permission.
DRAWING FILE REF
DRAWN BYCP
816-ES-00
(1:200 @ A3)
Mon. 20XX
DRAWING STATUSFeasibility
PROJECT
CLIENT
REVISION DATE
Studio 4.04 The Tea Building 56 Shoreditch High StreetLondon E1 6JJ T: 020 7033 9913 F: 020 7033 9914
STATUS
X0
1:100 @ A1
All dimensions to be checked on site prior to commencement of any works, and/or preparation of any shop drawings.
Sizes of and dimensions to any structural elements are indicative only. See structural engineers drawings for actual sizes/dimensions.
Sizes of and dimensions to any service elements are indicative only. See service engineers drawings for actual sizes and dimensions.
This drawing to be read in conjunction with all other Architect's drawings, specifications and other Consultants' information.
All proprietary systems shown on this drawing are to be installed strictly in accordance with the Manufacturers/Suppliers recommended details.
Any discrepancies between information shown on this drawing and any other contract information or manufacturers/suppliers recommendations is to be brought to the attention of the Architect.
DO NOT SCALE FROM THIS DRAWING.
DRAWING NOTES:
0 5 10 M
Thurloe Street
Pelham Street
Existing section
3.0m2.2m
Challenges & opportunities
2.4m
3.65m
GG
B
11
22
33
4
T h u r l o e S t r e e t
M u s e u m s u b w a y
P l a t f o r m
14
South Kensington ASD
TFL
DRAWING NOTES:
Existing Ground Floor Plan
000 Drawing NameSCALE
DATE
DRAWING
DWG No. REVISION
Information contained on this drawing is the sole copyright ofBuckley Gray Yeoman and is not to be reproduced without their permission.
DRAWING FILE REF
DRAWN BYCP
816-GA-01
(1:200 @ A3)
Mon. 20XX
DRAWING STATUSFeasibility
PROJECT
CLIENT
REVISION DATE
Stage D Design Freeze
Studio 4.04 The Tea Building 56 Shoreditch High StreetLondon E1 6JJ T: 020 7033 9913 F: 020 7033 9914
STATUS
X0
1:100 @ A1
Issued for Stage DRevised for Stage D
Draft Stage E Issue
Stage E Issue
Tender Addendum Issue
All dimensions to be checked on site prior to commencement of any works, and/or preparation of any shop drawings.
Sizes of and dimensions to any structural elements are indicative only. See structural engineers drawings for actual sizes/dimensions.
Sizes of and dimensions to any service elements are indicative only. See service engineers drawings for actual sizes and dimensions.
This drawing to be read in conjunction with all other Architect's drawings, specifications and other Consultants' information.
All proprietary systems shown on this drawing are to be installed strictly in accordance with the Manufacturers/Suppliers recommended details.
Any discrepancies between information shown on this drawing and any other contract information or manufacturers/suppliers recommendations is to be brought to the attention of the Architect.
DO NOT SCALE FROM THIS DRAWING.
DRAWING NOTES:
0 5 10 M
Existing Ground FloorScale: 1:1001
PROJECT NAME
CLIENT NAME
DRAWING NOTES:
Existing Ground Floor Plan
000 Drawing NameSCALE
DATE
DRAWING
DWG No. REVISION
Information contained on this drawing is the sole copyright ofBuckley Gray Yeoman and is not to be reproduced without their permission.
DRAWING FILE REF
DRAWN BYCP
816-EX-01
(1:200 @ A3)
Mon. 20XX
DRAWING STATUSFeasibility
PROJECT
CLIENT
REVISION DATESTATUS
X0
1:100 @ A1
All dimensions to be checked on site prior to commencement of any works, and/or preparation of any shop drawings.
Sizes of and dimensions to any structural elements are indicative only. See structural engineers drawings for actual sizes/dimensions.
Sizes of and dimensions to any service elements are indicative only. See service engineers drawings for actual sizes and dimensions.
This drawing to be read in conjunction with all other Architect's drawings, specifications and other Consultants' information.
All proprietary systems shown on this drawing are to be installed strictly in accordance with the Manufacturers/Suppliers recommended details.
Any discrepancies between information shown on this drawing and any other contract information or manufacturers/suppliers recommendations is to be brought to the attention of the Architect.
DO NOT SCALE FROM THIS DRAWING.
DRAWING NOTES:
0 5 10 M
Existing Ground FloorScale: 1:1001
Proposed Ground Floor Plan
Retain and restore entrances to residential
Existing footprint of retail units retained
Step free access down to ticket hall
Ground floor
Existing Ground Floor Plan
15
Retain and upgrade the existing building
Modernise the existing apartment layouts
Constraints to meeting modern plan standards
Residential upper floors
South Kensington ASD
TFL
DRAWING NOTES:
Existing Second Floor Mezz Plan
000 Drawing NameSCALE
DATE
DRAWING
DWG No. REVISION
Information contained on this drawing is the sole copyright ofBuckley Gray Yeoman and is not to be reproduced without their permission.
DRAWING FILE REF
DRAWN BYCP
816-GA-03
(1:200 @ A3)
Mon. 20XX
DRAWING STATUSFeasibility
PROJECT
CLIENT
REVISION DATE
Stage D Design Freeze
Studio 4.04 The Tea Building 56 Shoreditch High StreetLondon E1 6JJ T: 020 7033 9913 F: 020 7033 9914
STATUS
X0
1:100 @ A1
Issued for Stage DRevised for Stage D
Draft Stage E Issue
Stage E Issue
Tender Addendum Issue
All dimensions to be checked on site prior to commencement of any works, and/or preparation of any shop drawings.
Sizes of and dimensions to any structural elements are indicative only. See structural engineers drawings for actual sizes/dimensions.
Sizes of and dimensions to any service elements are indicative only. See service engineers drawings for actual sizes and dimensions.
This drawing to be read in conjunction with all other Architect's drawings, specifications and other Consultants' information.
All proprietary systems shown on this drawing are to be installed strictly in accordance with the Manufacturers/Suppliers recommended details.
Any discrepancies between information shown on this drawing and any other contract information or manufacturers/suppliers recommendations is to be brought to the attention of the Architect.
DO NOT SCALE FROM THIS DRAWING.
DRAWING NOTES:
0 5 10 M
Existing Second FloorScale: 1:1001
PROJECT NAME
CLIENT NAME
DRAWING NOTES:
Existing Second Floor Mezz Plan
000 Drawing NameSCALE
DATE
DRAWING
DWG No. REVISION
Information contained on this drawing is the sole copyright ofBuckley Gray Yeoman and is not to be reproduced without their permission.
DRAWING FILE REF
DRAWN BYCP
816-EX-03
(1:200 @ A3)
Mon. 20XX
DRAWING STATUSFeasibility
PROJECT
CLIENT
REVISION DATESTATUS
X0
1:100 @ A1
All dimensions to be checked on site prior to commencement of any works, and/or preparation of any shop drawings.
Sizes of and dimensions to any structural elements are indicative only. See structural engineers drawings for actual sizes/dimensions.
Sizes of and dimensions to any service elements are indicative only. See service engineers drawings for actual sizes and dimensions.
This drawing to be read in conjunction with all other Architect's drawings, specifications and other Consultants' information.
All proprietary systems shown on this drawing are to be installed strictly in accordance with the Manufacturers/Suppliers recommended details.
Any discrepancies between information shown on this drawing and any other contract information or manufacturers/suppliers recommendations is to be brought to the attention of the Architect.
DO NOT SCALE FROM THIS DRAWING.
DRAWING NOTES:
0 5 10 M
Existing Second Mezz FloorScale: 1:1001
Existing Upper Floor Plan
Proposed Upper Floor Plan 16
Retain building exterior and re-model interior
Extensive refurbishment
2
B u c k l e y G r a y Y e o m a n 17
South Kensington ASD
TFL
DRAWING NOTES:
Existing Section AA
000 Drawing NameSCALE
DATE
DRAWING
DWG No. REVISION
Information contained on this drawing is the sole copyright ofBuckley Gray Yeoman and is not to be reproduced without their permission.
DRAWING FILE REF
DRAWN BYCP
816-ES-00
(1:200 @ A3)
Mon. 20XX
DRAWING STATUSFeasibility
PROJECT
CLIENT
REVISION DATE
Studio 4.04 The Tea Building 56 Shoreditch High StreetLondon E1 6JJ T: 020 7033 9913 F: 020 7033 9914
STATUS
X0
1:100 @ A1
All dimensions to be checked on site prior to commencement of any works, and/or preparation of any shop drawings.
Sizes of and dimensions to any structural elements are indicative only. See structural engineers drawings for actual sizes/dimensions.
Sizes of and dimensions to any service elements are indicative only. See service engineers drawings for actual sizes and dimensions.
This drawing to be read in conjunction with all other Architect's drawings, specifications and other Consultants' information.
All proprietary systems shown on this drawing are to be installed strictly in accordance with the Manufacturers/Suppliers recommended details.
Any discrepancies between information shown on this drawing and any other contract information or manufacturers/suppliers recommendations is to be brought to the attention of the Architect.
DO NOT SCALE FROM THIS DRAWING.
DRAWING NOTES:
0 5 10 M
Thurloe Street
Pelham Street
Level the floors throughout to create
improved floor to ceiling heights
Add an additional storey
Install a new lift to create
accessible accommodation
Dual aspect flat layouts generally
BUT
Re-alignment of window positions at rear
required to incorporate new levels
Some compromises to meet modern
plan standards
Proposed Section
South Kensington ASD
TFL
DRAWING NOTES:
Existing Section AA
000 Drawing NameSCALE
DATE
DRAWING
DWG No. REVISION
Information contained on this drawing is the sole copyright ofBuckley Gray Yeoman and is not to be reproduced without their permission.
DRAWING FILE REF
DRAWN BYCP
816-ES-00
(1:200 @ A3)
Mon. 20XX
DRAWING STATUSFeasibility
PROJECT
CLIENT
REVISION DATE
Studio 4.04 The Tea Building 56 Shoreditch High StreetLondon E1 6JJ T: 020 7033 9913 F: 020 7033 9914
STATUS
X0
1:100 @ A1
All dimensions to be checked on site prior to commencement of any works, and/or preparation of any shop drawings.
Sizes of and dimensions to any structural elements are indicative only. See structural engineers drawings for actual sizes/dimensions.
Sizes of and dimensions to any service elements are indicative only. See service engineers drawings for actual sizes and dimensions.
This drawing to be read in conjunction with all other Architect's drawings, specifications and other Consultants' information.
All proprietary systems shown on this drawing are to be installed strictly in accordance with the Manufacturers/Suppliers recommended details.
Any discrepancies between information shown on this drawing and any other contract information or manufacturers/suppliers recommendations is to be brought to the attention of the Architect.
DO NOT SCALE FROM THIS DRAWING.
DRAWING NOTES:
0 5 10 M
Thurloe Street
Pelham Street
Existing Section
Challenges & opportunities
3.0m3.0m
3.65m3.65m
G
B
1
2
3
4
T h u r l o e S t r e e t
M u s e u m s u b w a y
P l a t f o r m
18
South Kensington ASD
TFL
DRAWING NOTES:
Existing Ground Floor Plan
000 Drawing NameSCALE
DATE
DRAWING
DWG No. REVISION
Information contained on this drawing is the sole copyright ofBuckley Gray Yeoman and is not to be reproduced without their permission.
DRAWING FILE REF
DRAWN BYCP
816-GA-01
(1:200 @ A3)
Mon. 20XX
DRAWING STATUSFeasibility
PROJECT
CLIENT
REVISION DATE
Stage D Design Freeze
Studio 4.04 The Tea Building 56 Shoreditch High StreetLondon E1 6JJ T: 020 7033 9913 F: 020 7033 9914
STATUS
X0
1:100 @ A1
Issued for Stage DRevised for Stage D
Draft Stage E Issue
Stage E Issue
Tender Addendum Issue
All dimensions to be checked on site prior to commencement of any works, and/or preparation of any shop drawings.
Sizes of and dimensions to any structural elements are indicative only. See structural engineers drawings for actual sizes/dimensions.
Sizes of and dimensions to any service elements are indicative only. See service engineers drawings for actual sizes and dimensions.
This drawing to be read in conjunction with all other Architect's drawings, specifications and other Consultants' information.
All proprietary systems shown on this drawing are to be installed strictly in accordance with the Manufacturers/Suppliers recommended details.
Any discrepancies between information shown on this drawing and any other contract information or manufacturers/suppliers recommendations is to be brought to the attention of the Architect.
DO NOT SCALE FROM THIS DRAWING.
DRAWING NOTES:
0 5 10 M
Existing Ground FloorScale: 1:1001
PROJECT NAME
CLIENT NAME
DRAWING NOTES:
Existing Ground Floor Plan
000 Drawing NameSCALE
DATE
DRAWING
DWG No. REVISION
Information contained on this drawing is the sole copyright ofBuckley Gray Yeoman and is not to be reproduced without their permission.
DRAWING FILE REF
DRAWN BYCP
816-EX-01
(1:200 @ A3)
Mon. 20XX
DRAWING STATUSFeasibility
PROJECT
CLIENT
REVISION DATESTATUS
X0
1:100 @ A1
All dimensions to be checked on site prior to commencement of any works, and/or preparation of any shop drawings.
Sizes of and dimensions to any structural elements are indicative only. See structural engineers drawings for actual sizes/dimensions.
Sizes of and dimensions to any service elements are indicative only. See service engineers drawings for actual sizes and dimensions.
This drawing to be read in conjunction with all other Architect's drawings, specifications and other Consultants' information.
All proprietary systems shown on this drawing are to be installed strictly in accordance with the Manufacturers/Suppliers recommended details.
Any discrepancies between information shown on this drawing and any other contract information or manufacturers/suppliers recommendations is to be brought to the attention of the Architect.
DO NOT SCALE FROM THIS DRAWING.
DRAWING NOTES:
0 5 10 M
Existing Ground FloorScale: 1:1001
Proposed Ground Floor Plan
Existing Ground Floor Plan
Ground floor
New residential entrances - positions retained
Existing footprint of retail units retained
Step free access down to ticket hall
Ground floor
19
Retain and upgrade the existing building
Create accessible apartments and install a new
lift and stairs
Meet current housing standards
South Kensington ASD
TFL
DRAWING NOTES:
Existing Second Floor Mezz Plan
000 Drawing NameSCALE
DATE
DRAWING
DWG No. REVISION
Information contained on this drawing is the sole copyright ofBuckley Gray Yeoman and is not to be reproduced without their permission.
DRAWING FILE REF
DRAWN BYCP
816-GA-03
(1:200 @ A3)
Mon. 20XX
DRAWING STATUSFeasibility
PROJECT
CLIENT
REVISION DATE
Stage D Design Freeze
Studio 4.04 The Tea Building 56 Shoreditch High StreetLondon E1 6JJ T: 020 7033 9913 F: 020 7033 9914
STATUS
X0
1:100 @ A1
Issued for Stage DRevised for Stage D
Draft Stage E Issue
Stage E Issue
Tender Addendum Issue
All dimensions to be checked on site prior to commencement of any works, and/or preparation of any shop drawings.
Sizes of and dimensions to any structural elements are indicative only. See structural engineers drawings for actual sizes/dimensions.
Sizes of and dimensions to any service elements are indicative only. See service engineers drawings for actual sizes and dimensions.
This drawing to be read in conjunction with all other Architect's drawings, specifications and other Consultants' information.
All proprietary systems shown on this drawing are to be installed strictly in accordance with the Manufacturers/Suppliers recommended details.
Any discrepancies between information shown on this drawing and any other contract information or manufacturers/suppliers recommendations is to be brought to the attention of the Architect.
DO NOT SCALE FROM THIS DRAWING.
DRAWING NOTES:
0 5 10 M
Existing Second FloorScale: 1:1001
PROJECT NAME
CLIENT NAME
DRAWING NOTES:
Existing Second Floor Mezz Plan
000 Drawing NameSCALE
DATE
DRAWING
DWG No. REVISION
Information contained on this drawing is the sole copyright ofBuckley Gray Yeoman and is not to be reproduced without their permission.
DRAWING FILE REF
DRAWN BYCP
816-EX-03
(1:200 @ A3)
Mon. 20XX
DRAWING STATUSFeasibility
PROJECT
CLIENT
REVISION DATESTATUS
X0
1:100 @ A1
All dimensions to be checked on site prior to commencement of any works, and/or preparation of any shop drawings.
Sizes of and dimensions to any structural elements are indicative only. See structural engineers drawings for actual sizes/dimensions.
Sizes of and dimensions to any service elements are indicative only. See service engineers drawings for actual sizes and dimensions.
This drawing to be read in conjunction with all other Architect's drawings, specifications and other Consultants' information.
All proprietary systems shown on this drawing are to be installed strictly in accordance with the Manufacturers/Suppliers recommended details.
Any discrepancies between information shown on this drawing and any other contract information or manufacturers/suppliers recommendations is to be brought to the attention of the Architect.
DO NOT SCALE FROM THIS DRAWING.
DRAWING NOTES:
0 5 10 M
Existing Second Mezz FloorScale: 1:1001
Existing Upper Floor Plan
Proposed Upper Floor Plan
Residential upper floors
20
Re-build behind historic facade retention
Retained Facade
3
B u c k l e y G r a y Y e o m a n 21
South Kensington ASD
TFL
DRAWING NOTES:
Existing Section AA
000 Drawing NameSCALE
DATE
DRAWING
DWG No. REVISION
Information contained on this drawing is the sole copyright ofBuckley Gray Yeoman and is not to be reproduced without their permission.
DRAWING FILE REF
DRAWN BYCP
816-ES-00
(1:200 @ A3)
Mon. 20XX
DRAWING STATUSFeasibility
PROJECT
CLIENT
REVISION DATE
Studio 4.04 The Tea Building 56 Shoreditch High StreetLondon E1 6JJ T: 020 7033 9913 F: 020 7033 9914
STATUS
X0
1:100 @ A1
All dimensions to be checked on site prior to commencement of any works, and/or preparation of any shop drawings.
Sizes of and dimensions to any structural elements are indicative only. See structural engineers drawings for actual sizes/dimensions.
Sizes of and dimensions to any service elements are indicative only. See service engineers drawings for actual sizes and dimensions.
This drawing to be read in conjunction with all other Architect's drawings, specifications and other Consultants' information.
All proprietary systems shown on this drawing are to be installed strictly in accordance with the Manufacturers/Suppliers recommended details.
Any discrepancies between information shown on this drawing and any other contract information or manufacturers/suppliers recommendations is to be brought to the attention of the Architect.
DO NOT SCALE FROM THIS DRAWING.
DRAWING NOTES:
0 5 10 M
Thurloe Street
Pelham Street
Retain the historic facade to Thurloe Street
Install a new lift to create accessible
accommodation
Level the floors throughout to create
improved floor to ceiling heights
Dual aspect flat layouts throughout
Add an additional storey
New south facing terraces/winter gardens
BUT
Requires demolition of existing rear facades
and building structure
Proposed Section
South Kensington ASD
TFL
DRAWING NOTES:
Existing Section AA
000 Drawing NameSCALE
DATE
DRAWING
DWG No. REVISION
Information contained on this drawing is the sole copyright ofBuckley Gray Yeoman and is not to be reproduced without their permission.
DRAWING FILE REF
DRAWN BYCP
816-ES-00
(1:200 @ A3)
Mon. 20XX
DRAWING STATUSFeasibility
PROJECT
CLIENT
REVISION DATE
Studio 4.04 The Tea Building 56 Shoreditch High StreetLondon E1 6JJ T: 020 7033 9913 F: 020 7033 9914
STATUS
X0
1:100 @ A1
All dimensions to be checked on site prior to commencement of any works, and/or preparation of any shop drawings.
Sizes of and dimensions to any structural elements are indicative only. See structural engineers drawings for actual sizes/dimensions.
Sizes of and dimensions to any service elements are indicative only. See service engineers drawings for actual sizes and dimensions.
This drawing to be read in conjunction with all other Architect's drawings, specifications and other Consultants' information.
All proprietary systems shown on this drawing are to be installed strictly in accordance with the Manufacturers/Suppliers recommended details.
Any discrepancies between information shown on this drawing and any other contract information or manufacturers/suppliers recommendations is to be brought to the attention of the Architect.
DO NOT SCALE FROM THIS DRAWING.
DRAWING NOTES:
0 5 10 M
Thurloe Street
Pelham Street
Existing Section
3.0m3.0m
3.65m3.65m
Challenges & opportunities
G
B
1
2
3
T h u r l o e S t r e e t
M u s e u m s u b w a y
P l a t f o r m
4
22
South Kensington ASD
TFL
DRAWING NOTES:
Proposed Ground Floor Plan
000 Drawing NameSCALE
DATE
DRAWING
DWG No. REVISION
Information contained on this drawing is the sole copyright ofBuckley Gray Yeoman and is not to be reproduced without their permission.
DRAWING FILE REF
DRAWN BYCP
816-GA-01
(1:200 @ A3)
Mon. 20XX
DRAWING STATUSFeasibility
PROJECT
CLIENT
REVISION DATE
Stage D Design Freeze
Studio 4.04 The Tea Building 56 Shoreditch High StreetLondon E1 6JJ T: 020 7033 9913 F: 020 7033 9914
STATUS
X0
1:100 @ A1
Issued for Stage DRevised for Stage D
Draft Stage E Issue
Stage E Issue
Tender Addendum Issue
All dimensions to be checked on site prior to commencement of any works, and/or preparation of any shop drawings.
Sizes of and dimensions to any structural elements are indicative only. See structural engineers drawings for actual sizes/dimensions.
Sizes of and dimensions to any service elements are indicative only. See service engineers drawings for actual sizes and dimensions.
This drawing to be read in conjunction with all other Architect's drawings, specifications and other Consultants' information.
All proprietary systems shown on this drawing are to be installed strictly in accordance with the Manufacturers/Suppliers recommended details.
Any discrepancies between information shown on this drawing and any other contract information or manufacturers/suppliers recommendations is to be brought to the attention of the Architect.
DO NOT SCALE FROM THIS DRAWING.
DRAWING NOTES:
0 5 10 M
Proposed Ground FloorScale: 1:1001
PROJECT NAME
CLIENT NAME
DRAWING NOTES:
Existing Ground Floor Plan
000 Drawing NameSCALE
DATE
DRAWING
DWG No. REVISION
Information contained on this drawing is the sole copyright ofBuckley Gray Yeoman and is not to be reproduced without their permission.
DRAWING FILE REF
DRAWN BYCP
816-EX-01
(1:200 @ A3)
Mon. 20XX
DRAWING STATUSFeasibility
PROJECT
CLIENT
REVISION DATESTATUS
X0
1:100 @ A1
All dimensions to be checked on site prior to commencement of any works, and/or preparation of any shop drawings.
Sizes of and dimensions to any structural elements are indicative only. See structural engineers drawings for actual sizes/dimensions.
Sizes of and dimensions to any service elements are indicative only. See service engineers drawings for actual sizes and dimensions.
This drawing to be read in conjunction with all other Architect's drawings, specifications and other Consultants' information.
All proprietary systems shown on this drawing are to be installed strictly in accordance with the Manufacturers/Suppliers recommended details.
Any discrepancies between information shown on this drawing and any other contract information or manufacturers/suppliers recommendations is to be brought to the attention of the Architect.
DO NOT SCALE FROM THIS DRAWING.
DRAWING NOTES:
0 5 10 M
Existing Ground FloorScale: 1:1001
Proposed Ground Floor Plan
Existing Ground Floor Plan
New residential entrances - positions retained
Footprint of retail units increased
Step free access down to ticket hall
Ground floor
23
Create accessible flats with new lifts and
stairs
Improve the quality and size of living spaces
Provide terrace space to the rear
South Kensington ASD
TFL
DRAWING NOTES:
Proposed Second Floor Plan
000 Drawing NameSCALE
DATE
DRAWING
DWG No. REVISION
Information contained on this drawing is the sole copyright ofBuckley Gray Yeoman and is not to be reproduced without their permission.
DRAWING FILE REF
DRAWN BYCP
816-GA-03
(1:200 @ A3)
Mon. 20XX
DRAWING STATUSFeasibility
PROJECT
CLIENT
REVISION DATE
Stage D Design Freeze
Studio 4.04 The Tea Building 56 Shoreditch High StreetLondon E1 6JJ T: 020 7033 9913 F: 020 7033 9914
STATUS
X0
1:100 @ A1
Issued for Stage DRevised for Stage D
Draft Stage E Issue
Stage E Issue
Tender Addendum Issue
All dimensions to be checked on site prior to commencement of any works, and/or preparation of any shop drawings.
Sizes of and dimensions to any structural elements are indicative only. See structural engineers drawings for actual sizes/dimensions.
Sizes of and dimensions to any service elements are indicative only. See service engineers drawings for actual sizes and dimensions.
This drawing to be read in conjunction with all other Architect's drawings, specifications and other Consultants' information.
All proprietary systems shown on this drawing are to be installed strictly in accordance with the Manufacturers/Suppliers recommended details.
Any discrepancies between information shown on this drawing and any other contract information or manufacturers/suppliers recommendations is to be brought to the attention of the Architect.
DO NOT SCALE FROM THIS DRAWING.
DRAWING NOTES:
0 5 10 M
Proposed Second FloorScale: 1:1001
PROJECT NAME
CLIENT NAME
DRAWING NOTES:
Existing Second Floor Mezz Plan
000 Drawing NameSCALE
DATE
DRAWING
DWG No. REVISION
Information contained on this drawing is the sole copyright ofBuckley Gray Yeoman and is not to be reproduced without their permission.
DRAWING FILE REF
DRAWN BYCP
816-EX-03
(1:200 @ A3)
Mon. 20XX
DRAWING STATUSFeasibility
PROJECT
CLIENT
REVISION DATESTATUS
X0
1:100 @ A1
All dimensions to be checked on site prior to commencement of any works, and/or preparation of any shop drawings.
Sizes of and dimensions to any structural elements are indicative only. See structural engineers drawings for actual sizes/dimensions.
Sizes of and dimensions to any service elements are indicative only. See service engineers drawings for actual sizes and dimensions.
This drawing to be read in conjunction with all other Architect's drawings, specifications and other Consultants' information.
All proprietary systems shown on this drawing are to be installed strictly in accordance with the Manufacturers/Suppliers recommended details.
Any discrepancies between information shown on this drawing and any other contract information or manufacturers/suppliers recommendations is to be brought to the attention of the Architect.
DO NOT SCALE FROM THIS DRAWING.
DRAWING NOTES:
0 5 10 M
Existing Second Mezz FloorScale: 1:1001
Existing Upper Floor Plan
Proposed Upper Floor Plan
Residential upper floors
24
The Bullnose & Arcade
B u c k l e y G r a y Y e o m a n
Our Approach
Pelham Street Opportunities
20-34 Thurloe Street
25
Massing options considered
B u c k l e y G r a y Y e o m a n
- - - - - - - - - Options not pursued ---- - - - -
Option 1
Option 2
26
Option 1
No additional storeysSmall scale improvements
B u c k l e y G r a y Y e o m a n 27
The proposals
Proposed Ground Floor - Base OptRetail Bullnose and Arcade
0 5 10 M
THURLOE ST
REET
PELHAM STREET
TICKET HALL
OX BLOOD Infill steam vent
3 9 0 s q f t
1 0 3 0 s q f t
2 0 0 s q f t
Proposed Ground Floor
The proposedground floor
Increase the amount of retail but
preserve the essence of the arcade
Maintain small retail units to the arcade
Larger units to the Bullnose - remove some
internal walls
Infill the steam vent
Units range in size from 200sqft to
900 sqft
PROJECT NAME
CLIENT NAME
DRAWING NOTES:Drawing Title
000 Drawing NameSCALE
DATE
DRAWING
DWG No. REVISION
Information contained on this drawing is the sole copyright ofBuckley Gray Yeoman and is not to be reproduced without their permission.
DRAWING FILE REF
DRAWN BYXX
Existing_00
(0:000 @ A3)
DD/MM/YY
DRAWING STATUSStatus
PROJECT
CLIENT
REVISION DATESTATUS
X0
0:000 @ A1
All dimensions to be checked on site prior to commencement of any works, and/or preparation of any shop drawings.
Sizes of and dimensions to any structural elements are indicative only. See structural engineers drawings for actual sizes/dimensions.
Sizes of and dimensions to any service elements are indicative only. See service engineers drawings for actual sizes and dimensions.
This drawing to be read in conjunction with all other Architect's drawings, specifications and other Consultants' information.
All proprietary systems shown on this drawing are to be installed strictly in accordance with the Manufacturers/Suppliers recommended details.
Any discrepancies between information shown on this drawing and any other contract information or manufacturers/suppliers recommendations is to be brought to the attention of the Architect.
DO NOT SCALE FROM THIS DRAWING.
DRAWING NOTES:
Existing Ground Floor
28
Option 2
“Destination” restaurant
First f loor extension
F i r s t G r o u n d
B u c k l e y G r a y Y e o m a n 29
Proposed Ground Floor - Base OptRetail Bullnose and Arcade
0 5 10 M
Main entrance THURLOE ST
REET
PELHAM STREET
TICKET HALL
OX BLOOD
2 0 5 0 s q f t
1 7 0 0 s q f t
Alternative approach
Small retai l units to the arcade maintained
Larger units on the Bullnose, one l inking to
an upper f loor
Signature restaurant opportunity
Proposed Ground Floor
South Kensington ASD
TFL
DRAWING NOTES: Proposed First Floor Opt 03 Retail - Bullnose and Arcade
-SCALE
DATE
DRAWING
DWG No. REVISION
Information contained on this drawing is the sole copyright ofBuckley Gray Yeoman and is not to be reproduced without their permission.
DRAWING FILE REF
DRAWN BYBGY
816_SK-208
(1:100 @ A3)
Feb 2016
DRAWING STATUSSKETCH
PROJECT
CLIENT
REVISION DATE
Stage D Design Freeze
Studio 4.04 The Tea Building 56 Shoreditch High StreetLondon E1 6JJ T: 020 7033 9913 F: 020 7033 9914
STATUS
-
1:50 @ A1
Issued for Stage DRevised for Stage DDraft Stage E IssueStage E IssueTender Addendum Issue
All dimensions to be checked on site prior to commencement of any works, and/or preparation of any shop drawings.
Sizes of and dimensions to any structural elements are indicative only. See structural engineers drawings for actual sizes/dimensions.
Sizes of and dimensions to any service elements are indicative only. See service engineers drawings for actual sizes and dimensions.
This drawing to be read in conjunction with all other Architect's drawings, specifications and other Consultants' information.
All proprietary systems shown on this drawing are to be installed strictly in accordance with the Manufacturers/Suppliers recommended details.
Any discrepancies between information shown on this drawing and any other contract information or manufacturers/suppliers recommendations is to be brought to the attention of the Architect.
DO NOT SCALE FROM THIS DRAWING.
DRAWING NOTES:
0 5 10 M
Areas approx. for review purposes only.
THURLOE ST
REET
PELHAM STREET
TICKET HALL
OX BLOOD
Proposed First Floor
30
UNDERSTANDING THE HERITAGE
B u c k l e y G r a y Y e o m a n 31
PROJECT NAME
CLIENT NAME
DRAWING NOTES:
Proposed Typical Shopfront
816_A-D-ShopfrontSCALE
DATE
DRAWING
DWG No. REVISION
Information contained on this drawing is the sole copyright ofBuckley Gray Yeoman and is not to be reproduced without their permission.
DRAWING FILE REF
DRAWN BYCP
ID-000
(1:40 @ A3)
May 2015
DRAWING STATUSStatus
PROJECT
CLIENT
REVISION DATESTATUS
X0
1:20 @ A1
All dimensions to be checked on site prior to commencement of any works, and/or preparation of any shop drawings.
Sizes of and dimensions to any structural elements are indicative only. See structural engineers drawings for actual sizes/dimensions.
Sizes of and dimensions to any service elements are indicative only. See service engineers drawings for actual sizes and dimensions.
This drawing to be read in conjunction with all other Architect's drawings, specifications and other Consultants' information.
All proprietary systems shown on this drawing are to be installed strictly in accordance with the Manufacturers/Suppliers recommended details.
Any discrepancies between information shown on this drawing and any other contract information or manufacturers/suppliers recommendations is to be brought to the attention of the Architect.
DO NOT SCALE FROM THIS DRAWING.
DRAWING NOTES:
0 55 M
SIGNAGESIGNAGESHOP
SIGNAGE
SOUTH KENSINGTON UNDERGOUND
TFL LONDON
Proposed ShopfrontScale: 1:252
1
4
5
6
7
89
The Arcade shopfronts
3 main heritage shopfront types:
Type 1
Offset door entrance
Signage zone
External signage
Bronze glazing
frames
Low stall-riser
Ventilation grilles
Shopfront Type 1 - Elevation
• Door location
• Recessed door
• Bay projection
• Transom lines
• Frame sizes
• Stallriser height
• Ventilation grille
• Fan light
• Signage
1
2
3
4
5
6
7
8
9
32
PROJECT NAME
CLIENT NAME
DRAWING NOTES:
Proposed Typical Shopfront
816_A-D-ShopfrontSCALE
DATE
DRAWING
DWG No. REVISION
Information contained on this drawing is the sole copyright ofBuckley Gray Yeoman and is not to be reproduced without their permission.
DRAWING FILE REF
DRAWN BYCP
ID-000
(1:40 @ A3)
May 2015
DRAWING STATUSStatus
PROJECT
CLIENT
REVISION DATESTATUS
X0
1:20 @ A1
All dimensions to be checked on site prior to commencement of any works, and/or preparation of any shop drawings.
Sizes of and dimensions to any structural elements are indicative only. See structural engineers drawings for actual sizes/dimensions.
Sizes of and dimensions to any service elements are indicative only. See service engineers drawings for actual sizes and dimensions.
This drawing to be read in conjunction with all other Architect's drawings, specifications and other Consultants' information.
All proprietary systems shown on this drawing are to be installed strictly in accordance with the Manufacturers/Suppliers recommended details.
Any discrepancies between information shown on this drawing and any other contract information or manufacturers/suppliers recommendations is to be brought to the attention of the Architect.
DO NOT SCALE FROM THIS DRAWING.
DRAWING NOTES:
0 55 M
SIGNAGESIGNAGESHOP
SIGNAGE
SOUTH KENSINGTON UNDERGOUND
TFL LONDON
Proposed ShopfrontScale: 1:252
1
23
89
7
6
4
Shopfront Type 2 - Elevation
• Door location
• Recessed door
• Bay projection
• Transom lines
• Frame sizes
• Stallriser height
• Ventilation grille
• Fan light
• Signage
1
2
3
4
5
6
7
8
9
Type 2
Recessed curved entrance
The Arcade shopfronts
Recessed
bulkhead
Curved glass
Recessed door
entrance
Original signage
33
The Arcade shopfronts
PROJECT NAME
CLIENT NAME
DRAWING NOTES:
Existing Sections AA&BB
000 Drawing NameSCALE
DATE
DRAWING
DWG No. REVISION
Information contained on this drawing is the sole copyright ofBuckley Gray Yeoman and is not to be reproduced without their permission.
DRAWING FILE REF
DRAWN BYCP
GS.00
(1:500 @ A3)
Jun. 2015
DRAWING STATUSFeasibility
PROJECT
CLIENT
REVISION DATESTATUS
X0
1:250 @ A1
All dimensions to be checked on site prior to commencement of any works, and/or preparation of any shop drawings.
Sizes of and dimensions to any structural elements are indicative only. See structural engineers drawings for actual sizes/dimensions.
Sizes of and dimensions to any service elements are indicative only. See service engineers drawings for actual sizes and dimensions.
This drawing to be read in conjunction with all other Architect's drawings, specifications and other Consultants' information.
All proprietary systems shown on this drawing are to be installed strictly in accordance with the Manufacturers/Suppliers recommended details.
Any discrepancies between information shown on this drawing and any other contract information or manufacturers/suppliers recommendations is to be brought to the attention of the Architect.
DO NOT SCALE FROM THIS DRAWING.
DRAWING NOTES:
0 5 10 M
TFL SIGNAGE TFL SIGNAGE SIGNAGESIGNAGESIGNAGESIGNAGESIGNAGESIGNAGESIGNAGESIGNAGESIGNAGE
Section AAScale: 1:501
SIGNAGE SIGNAGE SIGNAGE SIGNAGE SIGNAGE SIGNAGE SIGNAGE SIGNAGE SIGNAGE
Section BBScale: 1:502
South Kensington ASD
TFL
DRAWING NOTES:Drawing Title
000 Drawing NameSCALE
DATE
DRAWING
DWG No. REVISION
Information contained on this drawing is the sole copyright ofBuckley Gray Yeoman and is not to be reproduced without their permission.
DRAWING FILE REF
DRAWN BYXX
816_01_opt 07
(0:000 @ A3)
DD/MM/YY
DRAWING STATUSSKETCH
PROJECT
CLIENT
REVISION DATE
Stage D Design Freeze
Studio 4.04 The Tea Building 56 Shoreditch High StreetLondon E1 6JJ T: 020 7033 9913 F: 020 7033 9914
STATUS
X0
0:000 @ A1
Issued for Stage DRevised for Stage DDraft Stage E IssueStage E IssueTender Addendum Issue
All dimensions to be checked on site prior to commencement of any works, and/or preparation of any shop drawings.
Sizes of and dimensions to any structural elements are indicative only. See structural engineers drawings for actual sizes/dimensions.
Sizes of and dimensions to any service elements are indicative only. See service engineers drawings for actual sizes and dimensions.
This drawing to be read in conjunction with all other Architect's drawings, specifications and other Consultants' information.
All proprietary systems shown on this drawing are to be installed strictly in accordance with the Manufacturers/Suppliers recommended details.
Any discrepancies between information shown on this drawing and any other contract information or manufacturers/suppliers recommendations is to be brought to the attention of the Architect.
DO NOT SCALE FROM THIS DRAWING.
DRAWING NOTES:
Proposed First Floor - Opt 02Retail Bullnose and Arcade
0 5 10 M Type 3
Special Condit ions Near Entrances
Curved frontage
Ornate details
Shopfront Type 3 - Elevation
34
The Arcade interior
PROJECT NAME
CLIENT NAME
DRAWING NOTES:
Proposed Typical Shopfront
816_A-D-ShopfrontSCALE
DATE
DRAWING
DWG No. REVISION
Information contained on this drawing is the sole copyright ofBuckley Gray Yeoman and is not to be reproduced without their permission.
DRAWING FILE REF
DRAWN BYCP
ID-000
(1:40 @ A3)
May 2015
DRAWING STATUSStatus
PROJECT
CLIENT
REVISION DATESTATUS
X0
1:20 @ A1
All dimensions to be checked on site prior to commencement of any works, and/or preparation of any shop drawings.
Sizes of and dimensions to any structural elements are indicative only. See structural engineers drawings for actual sizes/dimensions.
Sizes of and dimensions to any service elements are indicative only. See service engineers drawings for actual sizes and dimensions.
This drawing to be read in conjunction with all other Architect's drawings, specifications and other Consultants' information.
All proprietary systems shown on this drawing are to be installed strictly in accordance with the Manufacturers/Suppliers recommended details.
Any discrepancies between information shown on this drawing and any other contract information or manufacturers/suppliers recommendations is to be brought to the attention of the Architect.
DO NOT SCALE FROM THIS DRAWING.
DRAWING NOTES:
0 55 M
SIGNAGESIGNAGESHOP
SIGNAGE
SOUTH KENSINGTON UNDERGOUND
TFL LONDON
Proposed ShopfrontScale: 1:252
Shopfront section detail
PROJECT NAME
CLIENT NAME
DRAWING NOTES:
Drawing Title
000 Drawing NameSCALE
DATE
DRAWING
DWG No. REVISION
Information contained on this drawing is the sole copyright ofBuckley Gray Yeoman and is not to be reproduced without their permission.
DRAWING FILE REF
DRAWN BYXX
GS.01
(0:000 @ A3)
Mon. 20XX
DRAWING STATUSFeasibility
PROJECT
CLIENT
REVISION DATESTATUS
X0
0:000 @ A1
All dimensions to be checked on site prior to commencement of any works, and/or preparation of any shop drawings.
Sizes of and dimensions to any structural elements are indicative only. See structural engineers drawings for actual sizes/dimensions.
Sizes of and dimensions to any service elements are indicative only. See service engineers drawings for actual sizes and dimensions.
This drawing to be read in conjunction with all other Architect's drawings, specifications and other Consultants' information.
All proprietary systems shown on this drawing are to be installed strictly in accordance with the Manufacturers/Suppliers recommended details.
Any discrepancies between information shown on this drawing and any other contract information or manufacturers/suppliers recommendations is to be brought to the attention of the Architect.
DO NOT SCALE FROM THIS DRAWING.
DRAWING NOTES:
0 5 10 M
Section CCScale: 1:501
Section CCScale: 1:501
Remove ad-hoc
fittings”
Remove iron entrance
screens and beam
Consider colour of
heritage elementsDoric columns
Tiffany style pendant lights
Original signs
Respect and augment the l isted
arcade features
35
Bringing this all together
No 2 No 2
PROJECT NAME
CLIENT NAME
DRAWING NOTES:
Existing Sections AA&BB
000 Drawing NameSCALE
DATE
DRAWING
DWG No. REVISION
Information contained on this drawing is the sole copyright ofBuckley Gray Yeoman and is not to be reproduced without their permission.
DRAWING FILE REF
DRAWN BYCP
GS.00
(1:500 @ A3)
Jun. 2015
DRAWING STATUSFeasibility
PROJECT
CLIENT
REVISION DATESTATUS
X0
1:250 @ A1
All dimensions to be checked on site prior to commencement of any works, and/or preparation of any shop drawings.
Sizes of and dimensions to any structural elements are indicative only. See structural engineers drawings for actual sizes/dimensions.
Sizes of and dimensions to any service elements are indicative only. See service engineers drawings for actual sizes and dimensions.
This drawing to be read in conjunction with all other Architect's drawings, specifications and other Consultants' information.
All proprietary systems shown on this drawing are to be installed strictly in accordance with the Manufacturers/Suppliers recommended details.
Any discrepancies between information shown on this drawing and any other contract information or manufacturers/suppliers recommendations is to be brought to the attention of the Architect.
DO NOT SCALE FROM THIS DRAWING.
DRAWING NOTES:
0 5 10 M
TFL SIGNAGE TFL SIGNAGE SIGNAGESIGNAGESIGNAGESIGNAGESIGNAGESIGNAGESIGNAGESIGNAGESIGNAGE
Section AAScale: 1:501
SIGNAGE SIGNAGE SIGNAGE SIGNAGE SIGNAGE SIGNAGE SIGNAGE SIGNAGE SIGNAGE
Section BBScale: 1:502
Proposed East Elevation
No 10 Access No 8 No 6 No 4Access to ticket hall
No 15No 13No 11
PROJECT NAME
CLIENT NAME
DRAWING NOTES:
Existing Sections AA&BB
000 Drawing NameSCALE
DATE
DRAWING
DWG No. REVISION
Information contained on this drawing is the sole copyright ofBuckley Gray Yeoman and is not to be reproduced without their permission.
DRAWING FILE REF
DRAWN BYCP
GS.00
(1:500 @ A3)
Jun. 2015
DRAWING STATUSFeasibility
PROJECT
CLIENT
REVISION DATESTATUS
X0
1:250 @ A1
All dimensions to be checked on site prior to commencement of any works, and/or preparation of any shop drawings.
Sizes of and dimensions to any structural elements are indicative only. See structural engineers drawings for actual sizes/dimensions.
Sizes of and dimensions to any service elements are indicative only. See service engineers drawings for actual sizes and dimensions.
This drawing to be read in conjunction with all other Architect's drawings, specifications and other Consultants' information.
All proprietary systems shown on this drawing are to be installed strictly in accordance with the Manufacturers/Suppliers recommended details.
Any discrepancies between information shown on this drawing and any other contract information or manufacturers/suppliers recommendations is to be brought to the attention of the Architect.
DO NOT SCALE FROM THIS DRAWING.
DRAWING NOTES:
0 5 10 M
TFL SIGNAGE TFL SIGNAGE SIGNAGESIGNAGESIGNAGESIGNAGESIGNAGESIGNAGESIGNAGESIGNAGESIGNAGE
Section AAScale: 1:501
SIGNAGE SIGNAGE SIGNAGE SIGNAGE SIGNAGE SIGNAGE SIGNAGE SIGNAGE SIGNAGE
Section BBScale: 1:502
Proposed West Elevation
No 9No 7No 5No 3No 1
Access to ticket hall
36
How it might look... .
B u c k l e y G r a y Y e o m a n 37
The Bullnose shopfronts
Linking to the station heritage
Take our lead from the original Bullnose
shopfronts
Create a stronger link with the arcade shopfronts
South Kensington ASD
TFL
DRAWING NOTES:
Existing Front Elevation
000 Drawing NameSCALE
DATE
DRAWING
DWG No. REVISION
Information contained on this drawing is the sole copyright ofBuckley Gray Yeoman and is not to be reproduced without their permission.
DRAWING FILE REF
DRAWN BYCP
816-EE-01
(1:200 @ A3)
Mon. 20XX
DRAWING STATUSFeasibility
PROJECT
CLIENT
REVISION DATE
Studio 4.04 The Tea Building 56 Shoreditch High StreetLondon E1 6JJ T: 020 7033 9913 F: 020 7033 9914
STATUS
X0
1:100 @ A1
All dimensions to be checked on site prior to commencement of any works, and/or preparation of any shop drawings.
Sizes of and dimensions to any structural elements are indicative only. See structural engineers drawings for actual sizes/dimensions.
Sizes of and dimensions to any service elements are indicative only. See service engineers drawings for actual sizes and dimensions.
This drawing to be read in conjunction with all other Architect's drawings, specifications and other Consultants' information.
All proprietary systems shown on this drawing are to be installed strictly in accordance with the Manufacturers/Suppliers recommended details.
Any discrepancies between information shown on this drawing and any other contract information or manufacturers/suppliers recommendations is to be brought to the attention of the Architect.
DO NOT SCALE FROM THIS DRAWING.
DRAWING NOTES:
0 5 10 M
SIGNAGE01
SIGNAGESIGNAGESIGNAGE01
01
SIGNAGE
01
01
SIGNAGE SIGNAGE
01
SIGNAGESIGNAGE
Bullose Elevation - Proposed shopfronts
Current shopfronts
38
Reinstatement of original shopfronts to match heritage detail
New retail and residential entrances respect the
original facade locations
Residential entrances lowered to provide level
access
South Kensington ASD
TFL
DRAWING NOTES:
Existing Front Elevation
000 Drawing NameSCALE
DATE
DRAWING
DWG No. REVISION
Information contained on this drawing is the sole copyright ofBuckley Gray Yeoman and is not to be reproduced without their permission.
DRAWING FILE REF
DRAWN BYCP
816-EE-01
(1:200 @ A3)
Mon. 20XX
DRAWING STATUSFeasibility
PROJECT
CLIENT
REVISION DATE
Studio 4.04 The Tea Building 56 Shoreditch High StreetLondon E1 6JJ T: 020 7033 9913 F: 020 7033 9914
STATUS
X0
1:100 @ A1
All dimensions to be checked on site prior to commencement of any works, and/or preparation of any shop drawings.
Sizes of and dimensions to any structural elements are indicative only. See structural engineers drawings for actual sizes/dimensions.
Sizes of and dimensions to any service elements are indicative only. See service engineers drawings for actual sizes and dimensions.
This drawing to be read in conjunction with all other Architect's drawings, specifications and other Consultants' information.
All proprietary systems shown on this drawing are to be installed strictly in accordance with the Manufacturers/Suppliers recommended details.
Any discrepancies between information shown on this drawing and any other contract information or manufacturers/suppliers recommendations is to be brought to the attention of the Architect.
DO NOT SCALE FROM THIS DRAWING.
DRAWING NOTES:
0 5 10 M
SIGNAGE01
SIGNAGESIGNAGESIGNAGE01
01
SIGNAGE
01
01
SIGNAGE SIGNAGE
01
SIGNAGESIGNAGE
Proposed Thurloe Street shopfronts
Original shopfront
Thurloe Street shopfronts
39
Proposed Elevation
Existing Elevation
Thurloe Street
Elevations
B u c k l e y G r a y Y e o m a n 40
How it might look... .