16
ARMCOR AIR SOLUTIONS PRODUCT GUIDE

ARMCOR AIR SOLUTIONS...Jul 20, 2016  · advice, supply of quality efficient heat recovery equipment, followed by well-balanced support to the sector. Armcor Air Solutions Heat Recovery

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ARMCOR AIR SOLUTIONS...Jul 20, 2016  · advice, supply of quality efficient heat recovery equipment, followed by well-balanced support to the sector. Armcor Air Solutions Heat Recovery

ARMCOR AIR SOLUTIONSPRODUCT GUIDE

Page 2: ARMCOR AIR SOLUTIONS...Jul 20, 2016  · advice, supply of quality efficient heat recovery equipment, followed by well-balanced support to the sector. Armcor Air Solutions Heat Recovery

2 | www.armcor.com.au

whO we AReArmcor Air Solutions is a dynamic professional company respected by the air-conditioning industry for its track record in providing advice, supply of quality efficient heat recovery equipment, followed by well-balanced support to the sector.

Armcor Air Solutions Heat Recovery and Air Handling Units are manufactured in Australia, providing a quality product with flexible design and lead times.

heAD OFFICe

Melbourne109-111 Northcorp Blvd, Broadmeadows VIC 3047T 1800 244 556e [email protected] w www.armcor.com.au

DISTRIBUTORS

Northern New South walesMcIntosh AirconditioningT 02 4962 1155e [email protected] www.mcintoshair.com.au

TasmaniaHVAC SuppliesT 03 6331 4209e [email protected] www.hvac-supplies.net

western AustraliaTurner EngineeringT 08 9236 3800e [email protected] www.turnerengineering.com.au

Northern QueenslandNorthern AirconditioningT 07 4774 3506e [email protected] www.northernairconditioning.com.au

Page 3: ARMCOR AIR SOLUTIONS...Jul 20, 2016  · advice, supply of quality efficient heat recovery equipment, followed by well-balanced support to the sector. Armcor Air Solutions Heat Recovery

CONTENTSCeiling Mounted Units - 4

Ceiling Units with EC Plug Fans - 6

Heat Recovery Fan Coil Units - 7

External Mounted Units - 8

Swimming Pool Units - 9

Reverse Cycle Package Units - 10

Indirect Evaporative Units - 11

Dehumidification Pre-Conditioner Units - 12

Rotary Heat Wheels - 13

Air Handling Units - 14

Project Showcase - 15

1800 244 556 | 3

Page 4: ARMCOR AIR SOLUTIONS...Jul 20, 2016  · advice, supply of quality efficient heat recovery equipment, followed by well-balanced support to the sector. Armcor Air Solutions Heat Recovery

CEILING UNITS

Model No Airflow(L/s)

Ext Static (Pa)

DimensionsH x L x W (mm)

Supply Air Spigot (mm)

Return Air Spigot (mm)

Weight(Kg) Phase

Filter SizeH x L x W

(mm)

XC 200 CM-1 200 120 270 x 900 x 600 200 200 27 1 305 x 255 x 10

XC 300 CM-1 300 220 430 x 1150 x 950 300 300 90 1 400 x 500 x 50

XC 400 CM-1 400 200 430 x 1150 x 950 350 350 90 1 400 x 500 x 50

XC 600 CM-1 600 200 430 x 1550 x 1250 400 400 190 1 400 x 700 x 50

XC 800 CM-1 800 150 550 x 1550 x 1250 400 400 210 1 520 x 700 x 50

XC 900 CM-1 900 150 700 x 1550 x 1250 400 x 400 400 x 400 230 1 670 x 700 x 50

XC 1000 CM-1 1000 120 830 x 1550 x 1250 450 x 450 450 x 450 245 1 800 x 700 x 50

XC 1200 CM-1 1200 110 830 x 1550 x 1250 450 x 450 450 x 450 245 1 800 x 700 x 50

CeILING MOUNTeD UNITS - SeRIeS 1

TeChNICAL TABLe

STANDARD FeATUReS• 200 L/sec - 1200 L/sec• Sensible or Enthalpy Heat Exchanger• Direct Drive Fans• Access Doors for Fans and Filters• Inbuilt 50mm Panel Filters• Hanging Brackets

W

C

L1

FreshAir

ExhaustAir

SupplyAir

ReturnAir

4 | www.armcor.com.au

Morphett Vale Primary, AdelaideHisense Arena, Melbourne

Page 5: ARMCOR AIR SOLUTIONS...Jul 20, 2016  · advice, supply of quality efficient heat recovery equipment, followed by well-balanced support to the sector. Armcor Air Solutions Heat Recovery

Model No Airflow(L/s)

Ext Static (Pa)

Dimensions H x L x W (mm)

Supply Air Spigot(mm)

Return Air Spigot

(mm)

Weight (Kg) Phase

Filter SizeH x L x W

(mm)

XC 200 CM-2 200 120 270 x 1100 x 600 200 200 35 1 305 x 255 x 10

XC 300 CM-2 300 220 430 x 1440 x 950 300 300 125 1 400 x 500 x 50

XC 400 CM-2 400 200 430 x 1400 x 950 350 350 125 1 400 x 500 x 50

XC 600 CM-2 600 200 430 x 1900 x 1250 400 400 200 1 400 x 700 x 50

XC 800 CM-2 800 150 550 x 1900 x 1250 400 400 210 1 520 x 700 x 50

XC 900 CM-2 900 150 700 x 1900 x 1250 400 x 400 400 x 400 225 1 670 x 700 x 50

XC 1000 CM-2 1000 120 830 x 1900 x 1250 450 x 450 450 x 450 240 1 800 x 700 x 50

XC 1200 CM-2 1200 110 830 x 1900 x 1250 450 x 450 450 x 450 240 1 800 x 700 x 50

CEILING UNITS

TeChNICAL TABLe

CeILING MOUNTeD UNITS - SeRIeS 2 OPTIONAL eXTRAS• 0-10V DC Speed Controller• Manual Speed Controller• Counterflow Heat Exchanger• Corrosion Resistant CoatingC

L2

W

FreshAir

ExhaustAir

SupplyAir

ReturnAir

1800 244 556 | 5

Redcliffe State High School, BrisbanePort of Brisbane Offices, Brisbane

Page 6: ARMCOR AIR SOLUTIONS...Jul 20, 2016  · advice, supply of quality efficient heat recovery equipment, followed by well-balanced support to the sector. Armcor Air Solutions Heat Recovery

L

W

CEILING UNITS WITH EC PLUG FANSSTANDARD FeATUReS• 200 L/sec - 1,200 L/sec• EC Plug Fans• Access Panels• Sensible or Enthalpy Heat Exchanger• Inbuilt Filters• Controls to suit BMS• Series 2 Option

Model No Airflow(L/s)

Ext Static (Pa)

DimensionsH x L x W (mm)

Supply Air Spigot

(mm)

Return Air Spigot

(mm)

Weight(Kg) Phase Filter Size

H x L x W (mm)

XC 200 CM-EC 200 120 270 x 900 x 600 200 200 33 240v/1 305 x 255 x 10

XC 300 CM-EC 300 200 430 x 1150 x 950 300 300 90 240v/1 400 x 500 x 50

XC 400 CM-EC 400 200 430 x 1150 x 950 350 350 90 240v/1 400 x 500 x 50

XC 600 CM-EC 600 200 430 x 1550 x 1250 400 400 210 240v/1 400 x 700 x 50

XC 800 CM-EC 800 200 550 x 1550 x 1250 400 400 240 415/3 520 x 700 x 50

XC 900 CM-EC 900 200 700 x 1550 x 1250 400 x 400 400 x 400 250 415/3 670 x 700 x 50

XC 1000 CM-EC 1000 200 830 x 1550 x 1250 450 x 450 450 x 450 260 415/3 800 x 700 x 50

XC 1200 CM-EC 1200 200 830 x 1550 x 1250 450 x 450 450 x 450 260 415/3 800 x 700 x 50

CeILING UNIT wITh eC PLUG FAN - SeRIeS 1

TeChNICAL TABLe

FreshAir

ExhaustAir

SupplyAir

ReturnAir

6 | www.armcor.com.au

Marsden Primary School, AdelaideMarysville Vibe Hotel

Page 7: ARMCOR AIR SOLUTIONS...Jul 20, 2016  · advice, supply of quality efficient heat recovery equipment, followed by well-balanced support to the sector. Armcor Air Solutions Heat Recovery

TeChNICAL TABLe

STANDARD FeATUReS• 300 L/sec - 1,200 L/sec• EC Plug Fans • Sensible or Enthalpy Heat Exchange• Chilled or Hot Water Coils• DX Coil with Optional Remote Condenser• Hanging Brackets• Access Doors• Inbuilt Filters

Model No Airflow(L/s)

DimensionsH x L x W (mm)

External Static (Pa)

Chilled Water Coil

(kW)

Hot Water Coil (kW)

DX Coil

Power (Volts/Phase)

Filter Type Inbuilt

XC 300 CM FCU 300 430 x 1650 x 1200 300 6 6 8 240/1 50mm Panel

XC 400 CM FCU 400 430 x 1650 x 1200 300 8 8 11 240/1 50mm Panel

XC 600 CM FCU 600 430 x 1900 x 1650 300 12 12 16 240/1 50mm Panel

XC 800 CM FCU 800 520 x 1900 x 1650 300 18 18 18 415/3 50mm Panel

XC 900 CM FCU 900 700 x 1900 x 1650 300 20 20 20 415/3 50mm Panel

XC 1000 CM FCU 1000 830 x 1900 x 1650 300 24 24 23 415/3 50mm Panel

XC 1200 CM FCU 1200 830 x 1900 x 1650 300 28 28 28 415/3 50mm Panel

FreshAir

ExhaustAir

SupplyAir

ReturnAir

HEAT RECOVERY FAN COIL UNITS

1800 244 556 | 7

Page 8: ARMCOR AIR SOLUTIONS...Jul 20, 2016  · advice, supply of quality efficient heat recovery equipment, followed by well-balanced support to the sector. Armcor Air Solutions Heat Recovery

EXTERNAL MOUNTED UNITSeXTeRNAL MOUNTeD UNITS

Model No Airflow (L/s)

Ext Static (Pa)

Dimensions H x L x W (mm)

Supply Air Spigot(mm)

Return Air Spigot (mm)

Weight(Kg) Fans Phase

XC 300 EM 300 200 1100 x 1200 x 600 350 x 350 400 x 300 225 Forward Curved 240/1

XC 400 EM 400 200 1100 x 1200 x 600 350 x 350 400 x 300 225 Forward Curved 240/1

XC 600 EM 600 200 1300 x 1300 x 900 600 x 350 600 x 350 330 Forward Curved 240/1

XC 800 EM 800 200 1300 x 1500 x 900 600 x 350 600 x 450 350 Forward Curved 240/1

XC 1000 EM 1000 250 1400 x 1600 x 900 600 x 450 650 x 450 420 EC Plug 415/3

XC 1200 EM 1200 250 1500 x 1800 x 1300 1000 x 350 1000 x 500 470 EC Plug 415/3

XC 1500 EM 1500 250 1500 x 2000 x 1300 1000 x 350 1000 x 500 500 EC Plug 415/3

XC 2000 EM 2000 250 2000 x 2200 x 1700 1400 x 500 1400 x 600 650 EC Plug 415/3

XC 2500 EM 2500 250 2000 x 2200 x 2100 1400 x 500 1800 x 600 720 EC Plug 415/3

XC 3000 EM 3000 250 2000 x 2200 x 2500 1600 x 600 2200 x 600 800 EC Plug 415/3

XC 4000 EM 4000 250 2000 x 2200 x 2900 1800 x 600 2400 x 600 1120 EC Plug 415/3

XC 5000 EM 5000 250 2000 x 2200 x 3300 2200 x 600 2800 x 600 1450 EC Plug 415/3

XC 6000 EM 6000 250 2000 x 2200 x 4100 2800 x 600 3600 x 600 1660 EC Plug 415/3

XC 7000 EM 7000 250 2000 x 2200 x 4900 3200 x 600 4400 x 600 1900 EC Plug 415/3

XC 8000 EM 8000 250 2000 x 2200 x 5700 3600 x 600 5200 x 600 2100 EC Plug 415/3

TeChNICAL TABLe

STANDARD FeATUReS• 300 L/sec - 10,000 L/sec• 50mm Colourbond Panel• EC Plug Fans or Forward Curved Fans• Sensible or Enthalpy Heat Exchanger• Support Base• Metu Frames

OPTIONAL eXTRAS• Hot Water Coil• Chilled Water Coil• Economy Cycle• Inbuilt Filters• Corrosion Resistant Coating• Return Air Bypass• Top Discharge• Counterflow Heat Exchanger

FreshAir

ExhaustAir

SupplyAir

ReturnAir

L

W

8 | www.armcor.com.au

Page 9: ARMCOR AIR SOLUTIONS...Jul 20, 2016  · advice, supply of quality efficient heat recovery equipment, followed by well-balanced support to the sector. Armcor Air Solutions Heat Recovery

Armcor Air Solutions offers a range of Xchange Energy Recovery Units specially designed for Indoor Swimming Pool Applications.The Xchange EP Series units are designed to operate with full fresh air to remove condensation, chlorine and other contaminates to maintain a safe, non-corrosive pool environment.The Xchange EP Series is incorporated with a polypropylene heat media. This media is designed to operate within corrosive pool environments without deterioration and carries an ARI Certified Performance Test Certificate.

STANDARD FeATUReS• 300 L/sec - 10,000 L/sec• Powdercoated EC Plug Fans• Corrosion Resistant Coating• Polypropylene Heat Media

FreshAir

ExhaustAir

SupplyAir

ReturnAir

L

W

SWIMMING POOL UNITS

1800 244 556 | 9

OPTIONAL eXTRAS• Hot Water Coil• Chilled Water Coil• DX Coil• Inbuilt Compressors• Remote Condenser• Inbuilt Filters• Economy Cycle• Condensing Boilers• Stainless Steel Drain Trays• Support Base• Metu Frames

Page 10: ARMCOR AIR SOLUTIONS...Jul 20, 2016  · advice, supply of quality efficient heat recovery equipment, followed by well-balanced support to the sector. Armcor Air Solutions Heat Recovery

Reverse Cycle Package units use 100% outdoor air for heating and air-conditioning the occupied area. Using Armcor Air Solutions heat recovery media the fresh air load is reduced by up to 75%. Increased energy savings can be achieved using an inbuilt economy cycle.

STANDARD FeATUReS• 500 L/sec - 10,000 L/sec• High Efficiency EC Plug Fans• 50mm or 75mm Colourbond Panel Cabinet• Sensible or Enthalpy Heat Exchanger• Support Base with Lifting Lugs• Drip Trays• Access Doors• Low Level Controls

OPTIONAL eXTRAS• Digital Compressors• Electronic TX Valves• Hot Water Coil• Economy Cycle• Return Air Bypass• High Level Interface• Co2 Sensor• Polypropylene Heat Media• Remote Condensor

REVERSE CYCLE PACKAGE UNITS

10 | www.armcor.com.au

Southern Cross UniversityRockhampton Girls Grammar

INBUILT PACKAGe UNITS

Inbuilt Package units are available with Danfoss Scroll Compressors using R407C.

CondensorAir

FreshAir

SupplyAir

ReturnAir

ExhaustAir

Page 11: ARMCOR AIR SOLUTIONS...Jul 20, 2016  · advice, supply of quality efficient heat recovery equipment, followed by well-balanced support to the sector. Armcor Air Solutions Heat Recovery

Indirect evaporative cooling systems are designed to pre-cool fresh air in drier climates, especially where there is a need for large amounts of air.Using a sensible heat exchanger a substantial reduction in temperature can be achieved without increasing the moisture content normally associated with evaporative cooling.These units are very economical to run, using water instead of the refrigeration cycle to reduce the temperature. These systems are simple and effective and more importantly help reduce carbon emissions.

STANDARD FeATUReS• 300 L/sec - 10,000 L/sec• Celdeck Pads• Sensible Heat Exchanger• EC Backward Curved Fans• Colourbond Panel Casing• Economy Cycle• Automatic Sump Dump

OPTIONAL eXTRAS• Gas Heating Package• DX Package• High Level Interface• Inbuilt Filters• Chilled and Hot Water Coils

APPLICATIONS• Aged Care Building Facilities• Large Foyers and Entrance Areas• Stairwell Pressurisation• Apartment Lobbies• Industrial Applications• Commercial Airconditioning• Large Retail Stores• Schools

FreshAir38°

20%rh

FreshAir38°

20%rh

ExhaustAir31°c

45%rh

SupplyAir

22°c50%rh

INDIRECT EVAPORATIVE UNITS

1800 244 556 | 11

North East Water, AlburyIkea Marsden Park, Sydney

Page 12: ARMCOR AIR SOLUTIONS...Jul 20, 2016  · advice, supply of quality efficient heat recovery equipment, followed by well-balanced support to the sector. Armcor Air Solutions Heat Recovery

The Dehumidification Pre-Conditioner units are designed to pre-condition both the temperature and humidity of a building’s fresh air supply. This system is the ideal solutions where humid conditions exist or where it is not practical to recover exhaust air.

STANDARD FeATUReS• 500 L/sec - 10,000 L/sec• Economy Cycle• Chilled Water Coils or DX Coils• Sensible Heat Exchanger• EC Plug Fans

OPeRATIONThe DHP Unit is designed to cool and dehumidify hot and humid outside air and supply the air at the return air temperature. As the air crosses the sensible heat exchanger, it is cooled by a cooling coil and then crosses the heat exchanger again to reheat to room return air temperature. This design enables free cooling and reheat.

• Inbuilt Bag Filters• Bypass Damper• Low Level Controls• Single or Twin Stage Compressors

SensibleHeat

Exchanger

Inbuilt Filters

Bypass Damper

EC Plug Fans

DX or Chilled Water Coil

FreshAir

SupplyAir

OPTIONAL eXTRAS• High Level Interface• Corrosion Resistance Coating• Hot Water Coil• Digital Scroll Compressors

DEHUMIDIFICATION PRE-CONDITIONER UNITS

12 | www.armcor.com.au

NIER Stage 1A, NewcastleBeijing Tea Shopping Centre, China

Page 13: ARMCOR AIR SOLUTIONS...Jul 20, 2016  · advice, supply of quality efficient heat recovery equipment, followed by well-balanced support to the sector. Armcor Air Solutions Heat Recovery

ROTARY HEAT WHEEL UNITRotary Heat Wheels provide high performance heat recovery efficiencies up to 85%.We have integrated the rotary heat wheel into our Colourbond Panel Cabinets combined with fans and optional heating or cooling coils, provides a complete range of customised units to suit any application.

STANDARD FeATUReS• 500 L/sec - 10,000 L/sec• Colourbond Panel Cabinet• Rotary Heat Wheel• Inbuilt Bag Filters• EC Plug Fans• Support Base

FreshAir

ExhaustAir

SupplyAir

ReturnAir

Inbuilt Filters

Support BaseHot Water Coil Cold Water Coil

EC Plug Fans

Rotary Heat WheelReturn Air Bypass

1800 244 556 | 13

• Fully wired to Switchboard• Drip Trays• Metu Frames• Economy Cycle

Page 14: ARMCOR AIR SOLUTIONS...Jul 20, 2016  · advice, supply of quality efficient heat recovery equipment, followed by well-balanced support to the sector. Armcor Air Solutions Heat Recovery

AIR HANDLING UNITS

14 | www.armcor.com.au

STANDARD FeATUReS• 300 L/sec - 15,000 L/sec• 50mm or 75mm Colourbond Panel Cabinet• EC Plug Fans or AC Plug Fan• Chilled & Hot Water Coils• Drip Tray• Filter Tracks• Large Access Doors• 0-10V DC Controlled Fans• Metu Frames

OPTIONAL eXTRAS• Multizone Applications• Filter Plenums• Internal Lights• Vertical or Horziontal Design• Sloping Roof

Supply Air

ReturnAir

Melbourne Airport T4

Bag Filter Hot Water Coil

Chilled Water Coil

AC/EC Plug FanPrefilter

Page 15: ARMCOR AIR SOLUTIONS...Jul 20, 2016  · advice, supply of quality efficient heat recovery equipment, followed by well-balanced support to the sector. Armcor Air Solutions Heat Recovery

PROJECT SHOWCASE

1800 244 556 | 15

1

1 Melbourne Airport T4

5 Melbourne Park Redevelopment

2 Arts West University, Melbourne

6 Ivanhoe Aquatic Centre

3 Gungahlin Aquatic and Leisure Centre, Canberra

7 SMCT New Function Centre, Springvale

4 Hawthorn Town Hall

8 Wagga Wagga Courthouse

3

5

7

2

4

6

8

Page 16: ARMCOR AIR SOLUTIONS...Jul 20, 2016  · advice, supply of quality efficient heat recovery equipment, followed by well-balanced support to the sector. Armcor Air Solutions Heat Recovery

109-111 Northcorp BlvdBroadmeadows VIC 3047T 1800 244 556e [email protected] www.armcor.com.au