8/11/2019 Arico v-series Temperature Controllers
1/4
V Series Temperature Controllers
User's manual
(21)Specifications
1 100240VAC10H, 50/60HZ
2. 2 * 4
3. 4
4. 0.5% 25J )
5. TC: J BK@@@ @@@RTD: Pt100
6. G@ @@
@ 250V NO:7A / NC:5A@@ @@@@Digital. DC24V/20mA
@ 010VA05VA15V
@ 020mAA420mA
Alarm1/2 & Aux.outputlG
RelayG250V NO:7A / NC:5A
Digital VoltageGDC24V/20mA
(* V Series output for aux. and alarm1/2 : 250V/5A)
7.
8. ON/OFF, PID
9.
10. 055J (32K130K)
@@@@@ 10%80%
. Power SupplyG
DisplayG digits
KeyG machinery keys
AccuracyG full scale (
Main InputG
OutputGMain output
RelayGVoltageG
Analog volt.G
Analog currentG
FunctionGHeating and cooling
Control ModeG
Alarm ModeG10
AmbientGTemperatureG
HumidityG (non-condensing)
(22)Wiring
Thank you for purchasing model V Series PID
Temperature Controller.
Before installing, connecting or using the instrument,
please go through this instruction manual
carefully and use the unit in proper manner.
VNA0000006
ARICO Technology Co., Ltd. reserves the right to
make any kind of design or functional modification
at any moment without prior notice.
Website:www.arico.com.tw E-mail:infoI arico.com.twVer.:1.0.8
V V3
V2 BV5
V4
8/11/2019 Arico v-series Temperature Controllers
2/4
(11)Faceplate (12)Key Operation
Level Key
Set Key
Increment Key
Decrement Key
(23)PID Control
1BEntry into level select mode and select level, and press intoparameter mode.
2BIn parameter mode, press level key leave parameter mode to
3BIn setting mode, press level key for saving parameter and return to
mode.parameter
Press for 2 sec to return to normal mode.
1BPress set key enable set value.
2BIn parameter mode, press set key for enable to set parameter.
3BIn setting mode, press set key for saving parameter or settingreturn to parameter mode.digit, and
1BIn level select mode, key to entry parameter modepress increment
2BIn parameter mode, key for selecting parameter.press increment
3BIn setting mode, key to increase the setting valueuntil high limit.
press increment
1BIn level select mode, press decrement key to entry parameter mode
2BIn parameter mode, key for selecting parameter.press decrement
3BIn setting mode, key to decrease the setting valueuntil low limit,,
press decrement
Press + at the same time for 2 sec to start or stop self-tuning.
Press decrement key for 2 sec to start or stop control output.
Press increment key for 2 sec to start or stop manual output.
Press set key for 8 sec to set the pass word "0044" automatically
Press to return to the head of level in parameter mode.
1. Output control mode
Main : PID Aux. : PID
Main : on/off Aux. : on/off
Main : on/off Aux. : PID
Main : PID Aux. : on/off
2. Output heating &cooling control mode
Main :heating Aux. :cooling
Main :cooling Aux. :heating
Auxiliary output function assists main output function in avoiding
the temperature out of control. They have opposite modes to
control.
3. Alarm Hysteresis band :
The output cycle time is one of important factor in control.It's
necessary to evaluate the heating and cooling system effici-
ency to set the output cycle time.suggest that the output
cycle time >20sec in relay output. If the output cycle time=0,
it will be analog output mode for that the higher temperature
stability system is desired,and the time=1~19 are for voltage
output mode and lower stability system.
4. Proportional Band : P
Range=1~100 or and it 's avalible to set by user.
5. Integral Time : I
The time is fluctuation.I
6. Differential Tim e : D
Range=0~250 units,1unit=0.1sec and 0 for disable.It's
avalible to set by user.
7. What is the "PID" Control?
"P" is proportional band and unit = or .It can describe
with the following equation:
P = [ ( SV - PV ) * 100 ] / proportional band
"D" is differential time and unit=0.1sec. If "D"=10,10*0.1=1
sec, it means that differential action will be executed once
per sec. The setting is smaller and the time is shorter and
the output percentage is fewer.
8. PID Value Self Tuning :
PID value self tuning has three types: The first is disable
for self tuning,the second is only once ,and the other is
every times after power on.
But it only will be executed by the following situations:
The setting value of heating system should be higher than
the present temperature for 45 or 85 .Or the setting
value of cooling system should be lower than the present
tem perature for 45 or 85 .If this function was executed
is desired,it's necessary to start this one, to set value,and
to comfirm that the temperature range is enough to execute it, then turn off the power supply and restart the instrument,
we will see the PID value and the flashing of decimal point
in the right-down horn.It will be shuted after changing value
during self tuning.
PVGNorm al modeGPres ent temp. Value
Level select modeGParameter level 1~4
Parameter modeGParameter name
SVGNormal modeGSetting valueBManual output percentage
Parameter modeGParameter value
OUT1GMain o utput indic ator
OUT2GAux. output indicator
AL1GAlarm 1 output indicator
AL2GAlarm 2 output indicator
Level select mode.
8/11/2019 Arico v-series Temperature Controllers
3/4
(41)Other Parameter Function (42)Error Messages
(32)Alarm Function (33)ON/OFF Control
Thermocouple
breaking
(43)Special Function
(44)Order Code
In ON/OFF control type, we can
set ON/OFF hysteresis band to
control temperature in desired range.
(34)Manual Control Type
The user can force to set output percentage.
(35)Output Function
ON/OFF hysteresis band
Alarm Range :
It's avalible to set alarm
0 to 99 in unit
Alarm Hysteresis band :
range from or
It's avalible to set alarmhysteresis band from 0 to 10in unit orAnd avoid temperature tounstable and fast change incritical point.
Alarm rang e Alarm rang e
Alarm rang e Alarm range
1. Relay Output :
It's better to set output cycle time >20sec in relay output. The setting
time is larger and the duration of relay is longer.
2. Digital voltage Output :
It's available to set output cycle time from 1 to 60 sec as user's
need in digital voltage output (24V).
3. Analog Output :
It's available to set the high and low limits of analog output after
the value of output cycle time equal 0. The range of analog
output are 0~20mA or 0~10V.
1. Password
Password has 4 digits.The units digit controls the using ofparameter level 1~4, the tens digit controls the setting of
Parameter level 1~4, and the other digits should be set by 0. The example is the following :
Password = 0023The parameter level 1~3 can be used and the level 1~2 canbe set.
*DP:Decimal point
2. Thermocouple type
3. Unit
The unit : or
4. Temperature Offset
The tem
perature offest range :
-99~+99 /
5. Main Output Percentage High Lim it :
This function can magnify and minifyof PID control.the output percentage
The related equation as the following: Output percentage after tuning = ( output percentage before
it ) / 100 tuning * output percentage high lim
6. Aux. Output Percentage High Lim it :
This function can magnify and minify the output percentageof PID control. The related equation as the following:
Output percentage after tuning = ( output percentage before
7. Restore The Default :
tuning * output percentage high limit ) / 100
This function will restore the default from the user's settings.
1.PID Self Tuning :The condition for starting : Present value should be lower than
setting for 45 . Present value will flash during executingself-tuning.
2.Manual Output Control : Under manual output control,setting value is manual output
percentage and setting output key to tuning output percentagedirectly.
(31)Dimension
TC type
Open
Short
JP1
JP2
PT type
Short
Open
J0 TYPE
J1 TYPE
K0 TYPE
K1 TYPE
PT0 TYPE
PT1 TYPE
No alarm
Low limit
High limit
Lo/Hi limit
Low limit standby
Lo/Hi limit standby
Reverse Lo/Hi limit
Absolute
Reverse Lo limit
Reverse Hi limit
Reverse Absolute
Unit: mm
J TYPE without DP,Range: 0~900 XC / 32 1200
J TYPE with DP, Range: 0.0~900.0 XC / 32.0~999.9 XF
K TYPE without DP,Range: 0~1200 XC / 32~1500 XF
K TYPE with DP, Range: 0.0~999.9 XC / 32.0~999.9 XF
PT TYPE without DP,Range: -200~500 XC / -328~900 XF
PT TYPE with DP, Range: -199.9~500.0 XC / -199.9~900.0 XF
~ XF
Model
1GMode
V100G48 48 mm
V200G48 96 mm
V300G72 72 mm
V400G96 96 mm
V500G96 48 mm
2 3GMain Output / Aux. Output
OGNone
RGRelay ( * )
VGDigital volt. Output 24V/20mA
IGAnalog current output 0~20mA, 4~20mA
LGAnalog volt. output 0~10V, 0~5V, 1~5V
/
4 / 5GAlarm 1 / 2
OGNone
RGRelay ( * )
VGDigital volt. output 24V/20mA
1 2 3 4 5
8/11/2019 Arico v-series Temperature Controllers
4/4
(36)Parameter Configuration Flow Chart
PV
SV:default=50C
Level 1 Level 2 Level 3
Main outputPercentageRange=0~100%
Aux. outputpercentageRange=0~100%
Alarm 1 Hi value
Range=0~99 J /K
Alarm 2 value
Range=0~99J /K
PID auto tuning:none
:Execute once :execute every
times
Control mode
See Table 1
Main & Aux. O/PHeating/coolingModeSee Table 2
Main O/P cycletimeRange=0~60sec
Aux. O/P cycletimeRange=0~60sec
Main O/P propor-Tional bandRange=0~100C/F
Aux. O/P propor-tional bandRange=0~100C/F
Main O/P different-ial timeRange=0~250/0.1s
Aux. O/P D time
Range=0~250/0.1s
Level 4
Alarm 1 mode
See Table 3
Manual O/P mode:enable
:disable
Alarm 1 deadbandRange=0~10 J /K
Alarm 2 mode
See Table 3
Alarm 2 dead
bandRange=0~10 J /K
Analog O/P lowlimitRange=0~200
Analog O/P highlimitRange=0~200
Password
Range=0000~9999
Thermocoupletype
See Table 4
Unit= orJ K
Input temp.offsetRange=-99~+99J/K
Main O/P propor-tional high limitRange=0~200
Aux. O/P propor-tional high limitRange=0~200
Restore default:usable
:disable
Main output hyst-eresis bandRange:1~100J /KDisplay in on/offcontrol mode
Aux. output hyst-eresis bandRange:1~100J/KDisplay in on/offcontrol mode
Main output I timeRangeG0~250/0.1sec
Aux. output I timeRangeG0~250/0.1sec
SV low limit
Range:Thermocouple
Low limit ~
(J /K)
SV high limit:Range: ~Thermocouple high limit
(J /K)
ake 5 Main O/P control model
use self tuning
control model
use auto tuning
control model
matters needing attention:
When use At control model.
Will have the excess temperature
henomenon in at calculation process.
inished until the calculation.
he calculation period PV right
ottom decimal point will glitter.
Level 2
Main & aux. output heating & cooling mode:Set the control modes of main & aux. heat-ing & cooling
Main output cycle time : Set the cycle timeof main output.
Aux. output cycle time : Set the cycle time
of aux. output.
Main output proportional band : Set thevalue P of main output proportional band.
Main output differential time : Set the valueD of main output differential time.
Aux. output differential time : Set the valueD of aux. output differential time.
Aux. output proportional band : Set thevalue P of aux. output proportional band.
Main output hysteresis band : Set thevalue of main output hysteresis bandDisplay and adjust in on/off control mode
Aux. output hysteresis band : Set thevalue of aux. output hysteresis bandDisplay and adjust in on/off control mode
Aux. output integral time : Set thevalue of aux. output integral time
Main output integral time : Set thevalue of main output integral time
SV high limit : Set the S V high limit fromSV low limit to the thermocouple highlimit
SV low limit : Set the SV low limit fromthe thermocouple low range to SV highlimit
Cooling delay : Set the range of PV exceedSV, the system will execute the cooling
Control mode : Set the control modes ofmain and aux. output.
Table 1 Output control mode
Main : PID Aux. : PID
Main : on/off Aux. : on/off
Main : on/off Aux. : PID
Main : PID Aux. : on/off
Table 2 Output heating &cooling control mode
Main :heating Aux. :cooling
Main :cooling Aux. :heating
Table 3 Alarm mode
Table 4 Input thermocouple type
*DP:Decimal point
Parameter description
Level 1
Level 3
Level 4
Main output percentage : Display the perc-entage of main output, and it was controledby PID control function.
Alarm 2 value : Set the range of alarm 2
Aux. output percentage : Display thePercentage of aux. output.
PID auto tuning : Execute the PID valueautomatically.
Manual output mode : Switch usable & dis-able for manual output.
Alarm 1 mode : Set the alarm 1 action mode
Alarm 1 hysteresis band : Set the value ofalarm 1 hysteresis band.
Alarm 2 mode : Set the alarm 2 action mode
Alarm 2 hysteresis band : Set the value ofalarm 2 hysteresis band.
Analog output low limit : Output the low limitwhen analog output
Analog output high limit : Output the highlimit when analog output
Password : Set the password to change theparameter using and setting.
Thermocouple type : Set the thermocoupletype.
Unit : or are selectable
Input temperature offset : Set offset value toincrease or decrease the present tempera-ture.
Main output percentage high limit : Set thepercentage high limit of main output
Aux. output percentage high limit : Set thepercentage high limit of aux. output
Default value : Restore default from theuser settings.
Range=0~99 J /K
Alarm 1 Low value
auto tuning switch
Yes:start AT tuning
NO:stop AT tuning
Main O/P
control model
Set Take 5
Cooling delayRangeG0~30J /K
Alarm 1 value : Set the low alarm range of
alarm 1
Alarm 1 value : Set the Hi alarm range of
alarm 1
Auto tuning model switch
Main output control model:Set the Auto tuning or Self tuning
J0 TYPE
J1 TYPE
K0 TYPE
K1 TYPE
PT0 TYPE
PT1 TYPE
(Take 6)
(Take 6)
(Take 6)
Soft start outputtime rangeG0~60min
Soft start output
Percent rangeG0~100%
Soft start output time : Heater dehumidifyTime
Soft start output percent : Heater dehumidifyOutput percent
(Take 6)
No alarm
Low limit
High limit
Lo/Hi limit
Low limit standby
Lo/Hi limit standby
Reverse Lo/Hi limit
Absolute
Reverse Lo limit
Reverse Hi limit
Reverse Absolute
ake 6 :the Main O/P control
model( ) set to mode
he PID parameter shows:
J TYPE without DP,Range: 0~900C/32 1200F
J TYPE with DP, Range: 0.0~900.0C/32.0~999.9F
K TYPE without DP,Range: 0~1200C/32~1500F
K TYPE with DP, Range: 0.0~999.9C/32.0~999.9F
PT TYPE without DP,Range: -200~500C/-328~900F
PT TYPE with DP, Range: -199.9~500.0C/-199.9~900.0F
~
Present value
digital filter time
0~60 sec