1/20For a Safe and Efficient Pigging Process
Argus Pig Valves
7/27/2019 Argus Products
2/20
Argus Machine Co. Ltd. has provided design expertise, quality manufacturing and reliable service to theoil and gas industry since 1958. Argus has a quality assurance program that is certified to API Q1 andISO 9001:2000. We hold five API licenses, assuring audited quality in all our products. For your piggingoperation we provide:
A double block & bleed valve that can launch or receive pigs.
Safe, efficient, cost effective means of pigging.
Capable of launching and receiving Bullet, Scraper and Spherical type pigs.
Threaded tailpiece stopper allows for the use of a longer pig, providing more effective pigging. Patented trunnion mounted ball for extended seat life and ease of operation.
Significantly reduces emissions compared to conventional launchers and traps.
Standard temperature range is -50F (-46C) to +250F (+121C).
Major components manufactured from forged A350-LF2.
Nickel plated trim for both sweet and sour services.
Designed in accordance with ASME, API, MSS and NACE requirements.
Covered by CRN #OC2161.2.
Patents applied for and granted.
Copyright
7/27/2019 Argus Products
3/20
ARGUS PIG VALVE WEIGHTS AND DIMENSIONS
2" A B C D E BALL CORE APPROX. Wt.
(Overall Length) I.D. (lbs) (kg)
150 ANSI RF 11.50 * (292) 5.62 (143) 4.00 (102) 7.62 (194) 5.50 (140) 2.50 (64) 135 (61)
150 ANSI RTJ 11.88 * (302) 5.62 (143) 4.00 (102) 7.62 (194) 5.50 (140) 2.50 (64) 135 (61)
300/600 ANSI RF 14.25 * (362) 5.62 (143) 4.00 (102) 7.62 (194) 5.50 (140) 2.50 (64) 145 (66)
300/600 ANSI RTJ 14.62 * (371) 5.62 (143) 4.00 (102) 7.62 (194) 5.50 (140) 2.50 (64) 145 (66)
900 ANSI RF 14.50 (368) 5.62 (143) 4.00 (102) 7.62 (194) 5.50 (140) 2.50 (64) 175 (80)
900 ANSI RTJ 14.62 (371) 5.62 (143) 4.00 (102) 7.62 (194) 5.50 (140) 2.50 (64) 175 (80)
LINE PIPE 11.00 * (279) 5.62 (143) 4.00 (102) 7.62 (194) 5.50 (140) 2.50 (64) 135 (61)
3" A B C D E BALL CORE APPROX. Wt.
(Overall Length) I.D. (lbs) (kg)
150 ANSI RF 12.75 * (324) 6.39 (162) 4.76 (121) 8.38 (213) 6.26 (159) 3.57 (90) 190 (86)
150 ANSI RTJ 13.12 * (333) 6.39 (162) 4.76 (121) 8.38 (213) 6.26 (159) 3.57 (90) 190 (86)
300 ANSI RF 14.00 * (356) 6.38 (162) 4.75 (121) 8.38 (213) 6.25 (159) 3.56 (90) 210 (95)
300 ANSI RTJ 14.12 * (359) 6.38 (162) 4.75 (121) 8.38 (213) 6.25 (159) 3.56 (90) 210 (95)
600 ANSI RF 14.00 (356) 6.38 (162) 4.75 (121) 8.38 (213) 6.25 (159) 3.56 (90) 210 (95)
600 ANSI RTJ 14.12 (359) 6.38 (162) 4.75 (121) 8.38 (213) 6.25 (159) 3.56 (90) 210 (95)
900 ANSI RF 15.00 (381) 6.39 (162) 4.76 (121) 8.38 (213) 6.26 (159) 3.57 (90) 230 (105
900 ANSI RTJ 15.12 (384) 6.39 (162) 4.76 (121) 8.38 (213) 6.26 (159) 3.57 (90) 230 (105
4" A B C D E BALL CORE APPROX. Wt.
(Overall Length) I.D. (lbs) (kg)
150 ANSI RF 15.50 * (394) 7.50 (191) 5.62 (143) 10.75 (273) 7.88 (200) 4.56 (116) 320 (146
150 ANSI RTJ 16.00 * (406) 7.50 (191) 5.62 (143) 10.75 (273) 7.88 (200) 4.56 (116) 320 (146
300 ANSI RF 16.00 * (406) 7.50 (191) 5.62 (143) 10.75 (273) 7.88 (200) 4.56 (116) 330 (150
300 ANSI RTJ 16.62 * (422) 7.50 (191) 5.62 (143) 10.75 (273) 7.88 (200) 4.56 (116) 330 (150
600 ANSI RF 17.00 (432) 7.50 (191) 5.62 (143) 10.75 (273) 7.88 (200) 4.56 (116) 350 (159
600 ANSI RTJ 17.12 (435) 7.50 (191) 5.62 (143) 10.75 (273) 7.88 (200) 4.56 (116) 350 (159
900 ANSI RF 18.00 (457) 7.50 (191) 5.62 (143) 10.75 (273) 7.88 (200) 4.56 (116) 390 (177
900 ANSI RTJ 18.12 (460) 7.50 (191) 5.62 (143) 10.75 (273) 7.88 (200) 4.56 (116) 390 (177
1500 ANSI RTJ 21.62 (549) 7.50 (191) 5.62 (143) 15.38 (391) 8.25 (210) 4.75 (121) 600 (273
6" A B C D E BALL CORE APPROX. Wt.
(Overall Length) I.D. (lbs) (kg)
150 ANSI RF 18.00 * (457) 9.00 (229) 7.12 (181) 12.12 (194) 9.25 (235) 6.75 (172) 580 (264
150 ANSI RTJ 18.38 * (467) 9.00 (229) 7.12 (181) 12.12 (194) 9.25 (235) 6.75 (172) 580 (264
300 ANSI RF 18.88 * (480) 9.00 (229) 7.12 (181) 12.12 (194) 9.25 (235) 6.75 (172) 620 (282
300 ANSI RTJ 19.38 * (492) 9.00 (229) 7.12 (181) 12.12 (194) 9.25 (235) 6.75 (172) 620 (282
600 ANSI RF 22.00 (559) 9.00 (229) 7.12 (181) 12.12 (194) 9.25 (235) 6.75 (172) 700 (318
600 ANSI RTJ 22.12 (562) 9.00 (229) 7.12 (181) 12.12 (194) 9.25 (235) 6.75 (172) 700 (318
900 ANSI RF 24.00 (610) 9.00 (229) 7.12 (181) 16.63 (422) 9.50 (241) 6.75 (172) 770 (350
900 ANSI RTJ 24.12 (613) 9.00 (229) 7.12 (181) 16.63 (422) 9.50 (241) 6.75 (172) 770 (350
1500 ANSI RTJ 28.00 (711) 10.31 (262) 8.63 (219) 17.47 (444) 10.00 (254) 7.00 (178) 1680 (764
8" A B C D E BALL CORE APPROX. Wt.(Overall Length) I.D. (lbs) (kg)
150 ANSI RF 23.50 * (597) 11.44 (291) 11.00 (279) 19.12 (486) 11.62 (295) 9.00 (229) 1915 (871)
150 ANSI RTJ 23.88 (607) 11.44 (291) 11.00 (279) 19.12 (486) 11.62 (295) 9.00 (229) 1915 (871)
300 ANSI RF 24.50 (622) 11.44 (291) 11.00 (279) 19.12 (486) 11.62 (295) 9.00 (229) 1965 (893)
300 ANSI RTJ 25.00 (635) 11.44 (291) 11.00 (279) 19.12 (486) 11.62 (295) 9.00 (229) 1965 (893)
600 ANSI RF 26.00 (660) 11.44 (291) 11.00 (279) 19.12 (486) 11.62 (295) 9.00 (229) 2085 (948)
600 ANSI RTJ 26.12 (663) 11.44 (291) 11.00 (279) 19.12 (486) 11.62 (295) 9.00 (229) 2085 (948)
900 ANSI RF 29.00 (737) 11.44 (291) 11.00 (279) 19.12 (486) 11.62 (295) 9.00 (229) 2215 (1007
900 ANSI RTJ 29.12 (740) 11.44 (291) 11.00 (279) 19.12 (486) 11.62 (295) 9.00 (229) 2215 (1007
1500 ANSI RTJ 33.12 (841) 12.69 (322) 11.00 (279) 21.00 (533) 12.94 (329) 9.38 (238) 3000 (1364
NOTES: 1. DIMENSIONS MARKED WITH * DO NOT MEET API SPECIFICATION 6D FOR FACE TO FACE LENGTH.
2. DIMENSIONS ARE IN INCHES; PARENTHESES ARE IN MILLIMETERS.3. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE.
Copyright
7/27/2019 Argus Products
4/20
PIG LAUNCHING & RECEIVING SEQUENCE
Step 1
Open position.
Step 2Close Valve.
Upstream and downstream issealed off.
Vent body cavity pressure.
Step 3Remove entry plug.
Insert pig into valve ball cavity.
Step 4Re-install entry plug.
Close vent valve.
Step 5Open valve.
Flowline pressure movesthe pig downstream.
Pig Launching
Step 1Open position.
Stopper in valve cavitystops pig.
Step 2Close Valve.
Upstream and downstream issealed off.
Vent body cavity pressure.
Step 3Remove entry plug.
Remove pig from valve ballcavity.
Step 4Re-install entry plug.
Close vent valve.
Step 5Open valve.
Flow brings the next pig alongto be trapped.
Pig ReceivingWhen used as a pig receiver the tailpiece stopper is used toreceive the pig.
ARGUS PIG VALVES INCREASED SAFETY, DECREASED EMISSIONS
3" 4" 6" 8"
Volume
(ft3)
Argus Pig Valve Conventional Barrel
0
1
2
3
4Argus Pig Valve vs.
Conventional BarrelPHYSICAL VOLUME (ft3)
SIZE ARGUS PIG VALVE CONVENTIONAL BARREL
3" 0.053 0.479
4" 0.106 1.086
6" 0.326 2.220
8" 0.706 3.491
Criteria used for this analysis:
(1) Argus valves are ANSI class 600
(2) Barrels are based on schedule 80 pipe
(3) Barrel dimensions:
3" Pipeline 4" x 72 inches long
4" Pipeline 6" x 72 inches long
6" Pipleine 8" x 72 inches long
8" Pipeline 10" x 84 inches long
Copyright
7/27/2019 Argus Products
5/20
ARGUS MULTI-PIG LAUNCHER
Close Pig Valve.
Shut-Off Valve on Pressure EnergizingLine must be closed.
Relieve pressure in Pig Launcher byopening the Blow-Down Valve.
Open Drain Valve on bottom of Pig Valve.
Unscrew Pressure Alert Valve on Closureto verify that the Pig Valve and Launcherare fully de-pressurized.
Open Closure and remove Pig Weightusing the Pig Weight Retriever (suppliedwith Launcher).
Install Pigs Nose First into theLauncher and re-install Pig Weightabove the Pigs.
Re-install Cap and Pressure Alert Vaon Closure.
Close Blow-Down Valve and Drain VShut-Off valve should be closed (SpReturn)
Open Shut-off Valve on PressureEnergizing Line.
Check Closure, Pressure Alert ValveBlow-Down Valve and Drain Valve foany leakage.
Pig Valve is now ready to launch pig
Faster, more efficient pigging operation, reduces downtime Reduces chance of exposure to pipeline media, ensuring a safer pigging operation Substantial reduction of hydrocarbon emissions Electric and pneumatic actuation is available Ideally suited for remote locations, lowering operating costs Substantial reduction in size of footprint Substantial weight and footprint reduction for offshore applications
REDUCE EMISSIONS WITH THE ARGUS MULTI-PIG LAUNCHER
PHYSICAL VOLUME (ft3)
SIZE ARGUS 6+1 CONVENTIONAL
MULTI-PIG LAUNCHER BARREL (**)
3" 0.337 3.353
4" 0.682 7.602
6" 2.248 15.54
8" 4.850 24.44
Criteria used for this analysis:
** For every seven pig runs
(1)Argus valves are ANSI class 600
(2) Barrels are based on schedule 80 pipe
(3) Barrel dimensions:
3" Pipeline 4" x 72 inches long
4" Pipeline 6" x 72 inches long
6" Pipleine 8" x 84 inches long
8" Pipeline 10" x 84 inches long 3" 4" 6" 8"
Volume
(ft3)
Argus6+1 Multi-Pig Launcher Conventional Barrel (**
0
5
10
15
20
25
Argus Multi-Pig Launcher vs.
Conventional Barrel
Copyright
7/27/2019 Argus Products
6/20Copyright
PIGGING WITH CONVENTIONAL BARRELSConventional launching and receiving of pigs using barrels and traps is costly and complicated. Additional lines andshut-off valves are required for the by-pass line, launcher and receiver. Installation and operation of this set up istime consuming.
PIGGING WITH THE ARGUS PIG VALVEWith the Argus Pig Valve, much of the above noted equipment is eliminated. Launching and receiving pigs is simplydone with the use of a single valve at each location.
Receiver
Launcher
Receiver
Launcher
7/27/2019 Argus Products
7/20
ARGUS URETHANE CUP & DISC PIGS
Copyright
4" ARGUS PIG
(STANDARD)
8" ARGUS PIG
(STANDARD)
4" ARGUS PIG
(BI-DIRECTIONAL)
PIPE WALLNOMINAL THICKNESS
PIG LENGTHCOLOUR DUROMETER
PIG SIZE inchesinches
(Shore A)(mm)
(mm)
YELLOW 70
2 INCH
.154 TO .188 4.50
BLUE 80(3.91 TO 4.78) (114.3)BLACK 90
PURPLE 60
.109 TO .125 5.75 GREEN 70
(2.77 TO 3.13) (146.0) RED 80
ORANGE 90
GREY 60
.156 TO .188 5.75 YELLOW 70
3 INCH (3.96 TO 4.78) (146.0) BLUE 80
BLACK 90
BI-DIRECTIONAL
5.75
GREEN 70
.109 TO .125 (146.0) RED 80
(2.77 TO 3.13) ORANGE 90
BI-DIRECTIONAL5.75
YELLOW 70
.156 TO .188(146.0)
BLUE 80
(3.96 TO 4.78) BLACK 90
PURPLE 60
.109 TO .125 7.50 GREEN 70
(2.77 TO 3.13) (190.5) RED 80
ORANGE 90
GREY 60
.156 TO .188 7.50 YELLOW 70
4 INCH (3.96 TO 4.78) (190.5) BLUE 80
BLACK 90
BI-DIRECTIONAL7.50
GREEN 70
.109 TO .125(190.5)
RED 80
(2.77 TO 3.13) ORANGE 90
BI-DIRECTIONAL7.50
YELLOW 70
.156 TO .188(190.5)
BLUE 80
(3.96 TO 4.78) BLACK 90
PURPLE 60
.109 TO .125 10.50 GREEN 70
(2.77 TO 3.13) (266.7) RED 80
6 INCHORANGE 90
GREY 60
.156 TO .280 10.50 YELLOW 70
(3.96 TO 7.11) (266.7) BLUE 80
BLACK 90
YELLOW 70
8 INCH.250 TO .375 14.75
BLUE 80(6.35 TO 9.53) (374.6)
BLACK 90
7/27/2019 Argus Products
8/20
ARGUS PIGGING SOLUTIONS FOR EVERY NEED
The Argus Pig Valve - a true double block and bleed valve that also allows pigs to be easily inserted or removed. It
provides you with a safer, more convenient and cost effective alternative to conventional pigging equipment. Call us for
your application and for a distributor near you.
SOLD & SERVICED BY:
Designed and Manufactured by:
Argus Machine Co. Ltd.
5820 97th Street Edmonton, AB Canada T6E 3J1
Phone: (780) 434 - 9451 Fax: (780) 434 - 9909
www.argusmachine.com
2007 Argus Machine Co. Ltd. All rights
1002-1-300
Design & Specifications subject to change without prior notice
Printed in Canada
ISO 9001: 2000
Reg i s t ra t i on Num b er: 0686
E d m o n to n , A l be r t a C a n a d a
Member
7/27/2019 Argus Products
9/20
Argus Pressure SwitchFor Reliable Pressure Control
7/27/2019 Argus Products
10/20
Switch to Argus!
Standard, Simple, and Reliable The Argus Pressure Switch has set the standard with a design that
provides unsurpassed durability and reliability.
Consider these features:
Microswitch trip mechanism makes field replacement
convenient.
Pressure sensing capsule utilizes an Inconel
diaphragm to withstand sour and corrosive media in
oil, gas and steam applications. All parts in contact with
the media meet the requirements of NACE MR0175.
Accurately responsive to working pressures ranging
from a minimum of 20 PSI (138 kPa) to a maximum
of 5000 PSI (34,470 kPa). All Argus switches are
proof-tested to 7500 PSI (51,710 kPa) and will sustain
rupture tests up to 20,000 PSI (137,900 kPa).
Functionally simple, yet versatileeach pressure spring
covers a wide range, with only a few variations required
to cover the full spectrum of pressure settings.
Tested over 1,000,000 cycles.
All models use the same trim to prevent misapplication
in the field.
Rugged design prevents the need for resetting after
installation.
External trip point adjustmentno need to remove the
switch housing cap.
Automatic or manual reset models available.
Optional vibration lock for severe, shock, or vibrating
service.
Bears the CSA NRTL/C mark, signifying that it is
certified for use in Canada and the United States.
Upon request all models are available with factory-
installed wiring harnesses.
All main components are manufactured from rolled bar
and sheet stock.
Patented
NRTL/C
Patented
7/27/2019 Argus Products
11/20
Product Specifications
General SpecificationsType: Automatic or Manual Reset Microswitch: Precision Snap Acting SPDT
Press. Sensing Element: Diaphragm
Setting: External Electrical Rating: Amp @ 125 VDC
Dead Band: Fixed Amp @ 250 VDC
Std. Process Connection: 2 NPT Male Thread 5 Amps @ 125, 250 or 480 VAC
Electrical Connection: NPT Female Thread 50/60 Hz
Service: Sour Low Temp. Proof Pressure: 7500 PSI (51,710 kPa)
Basic Dimensions: Automatic Reset-3.75 OD x 10.38 L
Manual Reset-3.75 OD x 11.06 Lg
Set Point Repeatability: 1% of Adjustable Range Approximate Weight: 10 lbs (4.54 kg)
Process Oper. Temp.: -50F to +600F Enclosure: Type 4
(-46C to +315C) Classification: CSA Class I, Div. 1 & 2, Group D
Hazardous Locations
Switch Housing Temp.: -50F to +185F
(-46C to +85C)
Argus Model No. Pressure Range
Automatic Manual (PSI) (kPa)
AEF-1.0 MBF-1.0 20 100 140 690
AEF-2.0 MBF-2.0 40 200 275 1380
AEF-8.0 MBF-8.0 80 800 550 5515
AEF-14 MBF-14 150 1400 1035 9650
AEF-20 MBF-20 250 2000 1720 13,790
AEF-50 MBF-50 1500 5000 10,340 34,470
MaterialsProcess Housing: ASTM A350-LF2 Class 1
-coated to combat corrosion
Electrical Housing: ASTM '6061-T6' Aluminum Pressure Diaphragm: Inconel, Grade 718
coated to combat corrosion
Seals: Fluorosilicone Microswitch: Beryllium Copper Spring
Design Specifications:ABSA: CRN No. OF2161.2134
ASME: B31.3 (Process Piping)
CSA: C22.2 No. 30 and C22.2 No.14 (Explosion-Proof Enclosures for Hazardous Locations)
NACE: MR-01-75 (Standard Material Requirements for Sour Service)
Patents: Applied for and Granted
Available Options:Access Collar Tamper-Proof Block Tamper-Proof Cap
Grayloc (GR-20) Process Connection (3720 PSI MOP @ 600F) Vibration Lock
Securemax (2SJ20) Process Connection (4025 PSI @ 600F)
Wiring Harness (See back page)
* Specifications are subject to change without prior noti
12
14
12
7/27/2019 Argus Products
12/20
Argus Wiring Harness
Argus Wiring Harness c/w Quick Connect 90 Elbow
Wiring Harness 3-Wire (14 Gauge)Length Part No.
15 ft. WH200006
20 ft. WH200007
30 ft. WH200008
40 ft. WH200009
50 ft. WH200010
60 ft. WH200011
Wiring harness may be factory installed on all models upon request
2006 Argus Machine Co. Ltd. All rights reserv
2006-1-3000-11
SOLD & SERVICED BY:
Designed and Manufactured by:
Argus Machine Co. Ltd.5820 97th Street Edmonton, AB Canada T6E 3J1
Phone: (780) 434 - 9451 Fax: (780) 434 - 9909
www.argusmachine.com
esign & Specifications subject to change without prior notice
rinted in Canada
Edmonton
Certified to
API Q1
5CT-0301
5L-0228
6A-0300
6D-0225
7-0106
Member
iring HarnessLength
15 ft.
20 t.
30 ft.
4 ft.
t.
60 ft.
7/27/2019 Argus Products
13/20
EDMONTON MANUFACTURING / ASSEMBLY DIVISIONS5820 - 97 STREET T6E 3J1 (780) 434-9451Assembly Fax (780) 434-9909 Manufacturing Fax (780) 438-1502
CALGARY SALES OFFICE#1540, 540 - 5 AVENUE SW T2P 0M2 (403) 263-3517
Fax (403) 263-3956
NISKU MANUFACTURING2327 - 5 STREET T9H 8H7 (780) 955-9314
Fax (780) 955-0220
The Next Generation ofOilfield Control
Switch, gauge and transmitter functions in a SINGLE device.
Argus Machine Co. Ltd.Since 1958
If you are monitoring pressure consider these features:
s0RESSURE Range 0 to 20680 kPa (0 to 3000 PSI)
s -46C to 85C (-50F to 185F)
s 2 NPT process connection
s$UAL3EAL#ERTIFIED
s On/off control coupled with pressure transmitting
s Dual high and low set points using two independent
programmable relayss Variable time delay of 0 to 99 seconds
s Programmable dead band
s User controlled automatic and manual reset options
s Programmable normally-open/normally-closed,independent on each relay
s User interface/programming can be performed live inhazardous environments
s Power options: 12 & 24V DC and 120V AC
Designed to meet:
s ANSI/ISA-12.27.01 s ASME B31.3
s CSA C22.2 No. 30 (Class 1 Division 1 & 2, Group DLocations)
s CSA C22.2 No. 142
E D M O N T O N s C A L G A R Y s N I S K U
EDMONTON MANUFACTURING / ASSEMBLY DIVISIONS5820 - 97 STREET T6E 3J1 (780) 434-9451Assembly Fax (780) 434-9909 Manufacturing Fax (780) 438-1502
CALGARY SALES OFFICE#1540, 540 - 5 AVENUE SW T2P 0M2 (403) 263-3517
Fax (403) 263-3956
NISKU MANUFACTURING2327 - 5 STREET T9H 8H7 (780) 955-9314
Fax (780) 955-0220
The Next Generation ofOilfield Control
Switch, gauge and transmitter functions in a SINGLE device.
Argus Machine Co. Ltd.
Since 1958
If you are monitoring pressure consider these features:
s0RESSURE Range 0 to 20680 kPa (0 to 3000 PSI)
s -46C to 85C (-50F to 185F)
s 2 NPT process connection
s$UAL3EAL#ERTIFIED
s On/off control coupled with pressure transmitting
s Dual high and low set points using two independent
programmable relayss Variable time delay of 0 to 99 seconds
s Programmable dead band
s User controlled automatic and manual reset options
s Programmable normally-open/normally-closed,independent on each relay
s User interface/programming can be performed live inhazardous environments
s Power options: 12 & 24V DC and 120V AC
Designed to meet:
s ANSI/ISA-12.27.01 s ASME B31.3
s CSA C22.2 No. 30 (Class 1 Division 1 & 2, Group DLocations)
s CSA C22.2 No. 142
www.argusmachine.com
7/27/2019 Argus Products
14/20
Argus Pressure Transmitter
Pressure Range 0 - 3000psi Response Times
Sensor Sampling Rate 10Hz
Over Pressure 4500psi Relays
7/27/2019 Argus Products
15/20
Pressure Isolation Valve
7/27/2019 Argus Products
16/20
The Argus PIV allows you to calibrate your safety equipment or perform maintenance without shutting in the line. In the open
position you have pressure gauge indication and process control. Close it and safely calibrate your Argus Pressure Switch or
Argus Pressure Pilot with ease. Once your maintenance is complete, simply return to the open position and youre back on line.
Its that easy!
The one-piece A350-LF2 body construction and NACE trim will handle the full spectrum of service conditions and temperature
ranges. Designed to provide safe, economical isolation from flowing product in crude oil, natural gas and condensate flow lines.
Pressure Isolation Valve
Designed & Manufactured by:
Argus Machine Co. Ltd.5820 - 97 Street, Edmonton, Alberta, Canada T6E 3J1Phone: (780) 434-9451 Fax: (780) 434-9909www.argusmachine.com
Features:
Short body pattern reduces the risk of freezing (optional volume displacer available).
One piece body construction.
Pressure equalization to prevent body cavity pressure buildup.
Bi-directional shutoff to full operating pressure.
Two position lockable handle.
Self-adjusting stem packing for trouble free service.
Positive ball core position indication.
Two " female NPT accessory ports.
Stem is backseated and blowout proof.
Specifications:
Body: A350-LF2 Ball: 316 Stainless SteelStem: 17-4 PH S.S. Bolting: Stainless Steel
Rated: 4000 PSI @ +100 F (27,580 kPa @ +38 C)*
Temp range: -50 F to +250 F (-46 C to +121 C)
Connections: 2" male NPT x 2" female NPT 150-1500 ANSI Class Integral Flange x 2" female NPT
Designed in accordance with ASME B16.34 and B31.3
for low temp sour service to meet NACE requirements.
*Rating for 2" NPT connections
Flange connection rating governed by ANSI class.
Note: Design and specifications may change without notice.
Printed in Canada
2006 Argus Machine Co
All rights rese
4000-2-1000-
7/27/2019 Argus Products
17/20
Argus Self-Contained Hydraulic Pump Module (HPM)
For dependable zero emission shutdown in local or remote locations, use the Argus Self-Contained Hydraulic PumpModule for Emergency Shutdown Systems. Designed with environmental preservation in mind, this system does notrequire an external source of power and is adaptable for use with either quarter turn or linear actuators.
Consider these Features: Simplified Control Circuit designed for use with the Argus Two-Line Pressure Pilot. Modular Design all functioning components are manifold mounted outside of the reservoir, to simplify
maintenance and reduce downtime. Single Pressure System eliminates the need for low pressure regulators and relief valves on the control circuit. Sealed System pressure vacuum breather combats the formation of condensation in the fluid reservoir. Manual Override is standard for quick shutdowns. Non-Foaming Hydraulics deflector fitting prevents entrapment of air in the hydraulic oil. Filtered Hydraulics filter elements strategically placed throughout the system assist in preventing damage to
system components. Coated Components to combat corrosion. Enhanced Safety The use of an optional closed circuit fusible plug with our system returns fluid directly to the
reservoir (rather than to atmosphere) in the event of a fire.
General Specifications for the HPM:Maximum System Supply Pressure ................................... 1500 PSI (10,342 kPa)Temperature Range: ............................................................ -50F to +200F (-46C to +93C)Boxed Dimensions: ............................................................. 10L x 8W x 23H (25.4 cm x 20.3 cm x 58.4 cm)Approximate Weight:........................................................... 26 lbs (11.8 kg)
Materials:Seals: .................................. Fluorosilicone , Highly Saturated Nitrile, & Low Temperature Nitrile
Components:....................... Aluminum, 6061-T6-Coated to combat corrosion
Fasteners & Fittings: ........... Plated Steel & Stainless Steel
7/27/2019 Argus Products
18/20
2006 Argus Machine Co.
All rights rese4000-2-1000-1
Designed and Manufactured by:
Argus Machine Co. Ltd.5820 97 Street, Edmonton, Alberta Canada T6E 3J1Phone: (780) 434-9451 Fax: (780) 434-9909www.argusmachine.com
Note: Design & Specifications may change without notice.Printed in Canada
Operating Procedures:
To start up the ESD system, lift the arming lever on the Latching Trip Valve.
Operate the hydraulic hand pump to open the flow-line valve.
If the flow-line pressure does not come within the high and low set points of the Pressure Pilot, oil flowing through
the Bias Restrictor will slowly allow the ESD valve to close.
If the flow-line pressure does come within the high and low set points of the Pressure Pilot, oil supplied through
the Bias Restrictor energizes the Latching Trip Valve. When the Latching Trip Valve is energized the arming lever
unlatches. The Pressure Pilot takes over control of the ESD system automatically.
System Schematic
SYSTEM 'SHUT- IN' FEATURES:
1. FLOW LINE PRESSURE GOES OUTSIDE
THE SET POINTS OF THE 'HIGH-LOW' PILOT.
2. HEAT SOURCE CAUSING THE MELTING OF
THE 'LOW MELT ALLOY' FOUND IN THE
FUSIBLE FITTING.
3. LOSS OF PNEUMATIC SIGNAL
TO N.O. RELAY VALVE.
4. LOSS OF ELECTRICAL SIGNAL
TO N.O. SOLENOID VALVE.
ARGUS
FUSIBLE
FITTING
SIGNAL
PORT
HYDRAULIC PUMP MODULE
MANIFOLD
FILTER
HAND
PUMP
INLET
CHECK
OIL
RESERVOIR
LEAK
TIGHT
OUTLET
CHECK
RELIEF
VALVE
DEFLECTOR
ORIFICE
OVER-RIDEVALVE
BIAS
RESTRICTOR
FLOW
LINE
ARGUS
ISOLATION
VALVE
ARGUS
HIGH-LOW
PILOT
SIGEXH
FIELD
TEST GAUGE
EXHAUST
PORT
VALVE
ACTUATOR
ACTUATOR
PORT
AUXILIARY
ACTUATOR
PORTS
AUXILIARY
EXHAUST
PORT
PNEUMATIC
SIGNA
L ARGUS
NORMALLY OPEN
RELAY VALVE
'EXH'
PORT
'IN'
PORT
P
1
2
3
4
S
A
E1
E2
A2
A1
'EXH'
PORT
NORMALLY OPEN
SOLENOID VALVE
MANUAL
RESET
'IN'
PORT LATCHING
TRIP VALVE
7/27/2019 Argus Products
19/20
Argus Hydraulic Pressure Pilot
Argus has taken the next step in providing you with a superior product. By incorporating the sensing
capsule design of the Argus Pressure Switch, which has been field proven for a number of years, we now
offer you this same technology in the Argus Pressure Pilot.
Consider these features:
Simplifies Control Circuits Designed for use with the Argus Self-Contained Hydraulic Pump
Module. Controls a maximum circuit pressure of 1500 PSI (10,342 kPa), utilizing the same
hydraulic pressure as the actuator.
Utilizes an Inconel pressure sensing capsule (patented) to withstand sour and corrosive
media in oil and gas applications from 50F (-46C) to plus 250F (+121C). All parts in
contact with the media meet the requirements of NACE MR0175.
Functionally simple, yet versatile, - each pressure spring covers a wide range, with only a few
variations required to cover the full spectrum of pressure settings.
Accurately responsive to working pressures ranging from a minimum of 20 PSI (138 kPa) to a
maximum of 5000 PSI (13,789 kPa). All Argus Pilots are proof-tested to ensure seal integrity.
All models use the same trim to prevent misapplication in the field.
All main components are manufactured from rolled bar and sheet stock.
Rugged design prevents the need for resetting after installation.
Easily adjustable set points. Separate springs for high and low pressure.
Exceeding set point pressure will not alter the set point calibration.
No brass or bronze components.
General Specifications:
Pressure Sensing Element: ................................................. Patented
Setting: ............................................................................... External
Process Connection: ........................................................... 2 NPT Male Thread(1)
Port Connections: ............................................................... 1/8 NPT Female Thread
Service Conditions: ............................................................. Sweet and Sour(2)
Instrument Media: ............................................................... Hydraulic Fluid
Temperature Range: ............................................................ -50F to +250F (-46C to +121C)
Maximum Operating Pressure: ........................................... 5000 PSI (34,473 kPa)
Basic Dimensions: .............................................................. 3.38 OD x 15 Lg. (8.59 cm x 38.1 cm)
Approximate Weight:........................................................... 22 lbs (10kg)
(1) Other connections may be available on request. Contact factory for your specific application.(2) Argus Pressure Pilots are manufactured to meet the requirements of NACE MR0175.
7/27/2019 Argus Products
20/20
Designed and Manufactured by:
Argus Machine Co. Ltd.5820 97 Street, Edmonton, Alberta Canada T6E 3J1Phone: (780) 434-9451 Fax: (780) 434-9909www.argusmachine.com
The Argus Pressure Pilot only requires two instrument lines, and four fittings to connect into a control
circuit. Teamed with the Argus Self-Contained Hydraulic Pump Module the field operator now has precise
system control and trouble free service.
Materials:
Process Housing: .................................................. ASTM A350-LF2 Coated to combat corrosion
Seals: .................................................................... Fluorosilicone , Low Temperature Nitrile, & Highly Saturated Nitrile
Poppet Block: ........................................................ Aluminum, 6061-T6-Coated to combat corrosionPressure Diaphragm: ............................................ Inconel, Grade 718
Design Specifications:
Designed and manufactured to meet the requirements of:
ASME: ................................................................... B31.3 (Process Piping)
NACE: .................................................................... MR0175 (Standard Material Requirements for Sour Service)
Patents: ................................................................. Applied For
Set Point Ranges:
Hydraulic Models: AHPL (Argus Hydraulic Pilot Low Pressure) AHPH (Argus Hydraulic Pilot High Pressure)
HIGH (Increasing) 130 to 2600 PSI (896 to 17,927 kPa) 400 to 5000 PSI (2758 to 34,474 kPa)
LOW (Decreasing) 20 to 600 PSI (138 to 4137 kPa) 50 to 800 PSI (345 to 5516 kPa)
** Contact Argus to confirm available set points
When ordering your Argus Pressure Pilot, please ensure you have the following information readily
available to ensure a proper fit with your application:
Operating Environment:
Service Media: Crude Oil, Natural Gas, Other Service Conditions: Sweet, Sour, Other
Maximum Working Pressure:
Minimum & Maximum Operating & Ambient Temperatures
Special Requirements: ie. Isolation Valve, Flanged Connections, etc.
* Contact factory or your local representative for more information.
System Specifications:
High and Low Set Point Pressure