2
Complete range of Electro Surgical Solutions Add Hi-Tech Precision to your Surgical Expertise... H i g h P e r f o r m a n c e With all Reusable Attachments Argon Plasma Coagulator

Argon XMT-MK-AP1 rev 04 JUL-19 - MEDICA

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Argon XMT-MK-AP1 rev 04 JUL-19 - MEDICA

Complete range of

Electro Surgical Solutions

Add Hi-Tech Precision to your Surgical Expertise...

H i g h P e r f o r m a n c e

With al l Reusable Attachments

Argon Plasma Coagulator

Page 2: Argon XMT-MK-AP1 rev 04 JUL-19 - MEDICA

OUTPUT FLOW RANGE• Cut and Coag Flow rates:0.1-12 Standard Ltr/Min. with resolution of - 0.1 Ltr/Min for flowrates between 0.1-5 lpm - 0.2 Ltr/Min for flowrates between 5-10 lpm - 0.5 Ltr/Min for flowrates between 10-12 lpm

MODES• Cut : Open, Laparo

Coagulation : Open, Laparo, Gastro, Pulse• Introduced new Pulse mode with various pulse effects.•

GAS FILTRATION SYSTEM0.5 Micron external filter for Gas input0.1 Micron external filter for Gas output

INDICATOR

• Cylinder Gas level indicator : 0 to 100%

• Visual indicator for system warnings & errors.

• Beep tones for warning and errors.

• Over pressure indicator

DESIGN STANDARDClassification according to the EC- Directive 93/ 42/ EEC: Class IIbGeneral Safety Standards: IEC 60601-1-1, IEC 60601-2-2 EMI/EMC Compatibility Standard: IEC 60601-1-2IS Safety Standard: IS 7583

INPUT POWER (other ratings available on request)Operating Voltage : 165-265 Volt AC, 50-60 Hz, Fuse : 2 AFrequency : 50-60 Hz Current : 2 Amp

DIMENSIONSL x W x H in cm - 38.0 x 31.0 x 12.0, Weight in kg < 8.0

• Unit with 5" LCD Touch Panel.

• Fully microprocessor controlled : To achieve high degree of clinical precision.

• Argon Gas Level indicator with built in high pressure regulator.

• Separate flow setting for cut & coagulation.

• Device can switch between Electro-surgery Cut/Coag and Argon assist cut/coag.

• User set able flow rate range : 0.1 to 12 Ltr/Min.

• Internal purging facility which fill the accessory with non-ionized gas before surgery.

• Facility to detect over pressure from body and give an alarm in such condition.

• Internal leakage detection for Argon gas.

• Accessory selection option provided for Gastroscopy, Open and Laparoscopy surgery.

• Ten user settable programs with procedure, surgeon name, flow & modes can be saved in the system.

• Single hose pipe connection between the system and the cylinder.

• Decreases smoke while performing cut and coagulation.

• Its is based non-contact coagulation technique, it performs coagulation with less carbonization.

• Decreases blood loss, rebleeding, minimal tissue damage.

• Argon is inert, non-combustible and easily ionizable gas.

• The RF energy ionizes argon gas and produces plasma which helps in non-contact coagulation &

improves the quality of coagulation.

• Heavier than air, displacing Nitrogen & Oxygen have avoid tissue burning & smoke.

• Produces flexible eschar.

• Gastroscopy • Colonoscopy • Bronchoscopy • Laparoscopy Surgery • Onco Surgery, Open and General Surgical applications

XM

T/M

K/A

P1 r

ev

: 04 J

UL/1

9 C

opyr

ight by

XM

TP

L

INPUT GAS PRESSURE• Maximum input pressure of Argon Gas 150 Bar

OUTPUT GAS PRESSURE• 2.5 ± 0.5 bar