Upload
jillianix
View
32
Download
1
Tags:
Embed Size (px)
DESCRIPTION
lift
Citation preview
MID RISE
Escalator & Moving Walk
SIGMA constantly endeavors to improve products so that information in this catalog is subject to change without notice.
2009. 12 Printed in Korea / Revision No. 3
Sigma Commercial Escalators are well suited for today’s urban structures. Newtechnological advancements have been applied to make escalator the world-best indesign and safety. New technology and aero-dynamic design make Sigma escalatorsappealing while improved strength and safety features offer security to users.
Sigma escalators will continue to meet customer demands with higher goals thanexpected. With certificates to meet various standards around the world, we offer the bestquality and safety with Sigma escalators.
02 03
The Essence of World Best Technologies..
Escalator touches the heart of people all around the world
Lotus Shopping Center Thailand
Tsuenwan PlazaHong Kong
Yangon Trade CenterMyanmar
Yuzana PlazaMyanmar
Diamond PlazaVietnam
Pearl Continental HotelPakistan
Metro Shopping MallBangladesh
UTC BorakBangladesh
Al-Khaleej Shopping CenterU.A.E
Homoud TowerKuwait
Central PlazaKuwait
Grand Hyatt HotelIndonesia
Incheon International AirportKorea
Rockwell CenterPhilippines
Dubai Business CenterU.A.E
Zara CenterAmman
Centro SambilVenezuela
CTRO.C. Galerias EL ParaisoVenezuela
Baiyoke Sky HotelThailand
DesignArtistic design with smooth and natural lines
RobustStrength with comfort andlow noise
SafetyElimination of thesource of safety hazards
Low Noise & Minimal VibrationSIGMA owns the largest and perfect noise testing room,which keeps all the passengers apart from noise annoyance.
Artistic design, best safety and best ride
New concept of engineering
Safe and low noise escalator
04
Better World with Sigma Escalators...
TECHNOLOGYBetter design for a better world...
DESIGN
Glass panel
Clear Glass
Floor
Stainless steel
Direction indicator Various colors for handrails
Aluminium (Option) Aluminium (Option)
※Above colors may differ from the actual color due to printing
SIGMA escalator’s unique design and various
design options make assimilation with building
aesthetics possible.
∙Ebony (Black) ES-01∙Scarlet ES-10 (Option)∙Sapphire ES-27 (Option)∙Crimson ES-20 (Option)∙Mid Grey ES-12 (Option)∙Emerald ES-29 (Option)
05
Standard Option
(Option)
� Comb Plate Switch � Safety Guard at upper and lower machine rooms
� Step Safety Switch � Entry Switch � Skirt Guard Safety Device
� Driving Chain Safety Device
� Step Roller Safety Device � Step Chain Safety Device � Emergency Stop Device � Expanded Maintenance Area
Safety is the foundation of design...
SAFETY INNOVATION
06 07
Handrail inlet engineered through
emergency tests.
If engaging force is over 5kg, the deflect
cover will be separated safely.
Entry Box Engineered to prevent fingers getting
caught between frame and handrail
(Gap 2mm)
HandrailSurpass EN Code requirements
(Gap 3mm)Gap between
step and skirt guard
∙Self-diagnostic functions with remote communication
∙Engineered through field know-how
∙Advanced safety system with robust design
Skirt Guard Safety DeviceStop escalator if objects are caught between step and skirt.
Comb Plate Safety SwitchStop escalator if objects are caught between comb plate and step treads.
Entry SwitchStop escalator if hand or object is pulled into the handrail inlet.
Driving Chain Safety DeviceStop escalator if the driving chain breaks or excessively loosen.
Step Safety SwitchStop escalator if steps are operating in abnormal manner due to fracturedstep.
Emergency Stop DeviceIn an emergency, stop the escalator immediately if pressed.
Step chain Safety DeviceStop escalator if the step chainbreaks or becomes loose.
Step Roller Safety DeviceStop escalator if steps are operating in abnormal manner due to reasons such as foreign matters being caught between steps.
Green LightTake care of the passengers for riding safety.
Non-reversing Safety DeviceStop escalator if its direction of operating is reversed.
Handrail Static DevicePrevent static electricity with handrail brush installed blocking static electricity
08 09
Structure & Safety Device
Additional safety device options
Overspeed DetectorStop escalator if operating above normal speed
Auxiliary BrakeStop escalator if the driving chain breaks or over speed
Brake Lining Wear Safety DeviceStop escalator if the lining of main brake is worn abnormally
Handrail Speed DetectorStop escalator if handrail speed is below normal due to
handrail breakge or elongations
Handrail Broken Safety DeviceStop escalator if handrail breaks or stops
EMERGENCY STOP DEVICE
CONTROLLER
TRUSS
STEP
DECK
RAILSKIRT GUARD
HANDRAIL
GLASS PANEL
DRIVING UNIT
HANDRAIL DRIVING PULLEY
HANDRAIL ENTRY BOX
COMB
FLOOR
Layout & Technical Data\
10 11
Layout (Rise: 2050mm ~ 6000mm) Technical Data (Rise 2050mm~6000mm)
WORKING POINT WORKING POINT
H(RI
SE)
K
FL.
FL.
W3
MIN.PIT WIDTH
MIN
.PIT
DEP
TH
W2W1W
FINISHED FLOOR (BY OTHERS)
FINISHED FLOOR(BY OTHERS)
L=L1+A+B+100
MIN.M
H(RI
SE)
J
MIN
.K
D
Y
Y
800 J
FL.
L1=(30。=1.732×H,35。=1.428×H)
L=L1+A+B+100
RAILING
(BY OTHERS)
(BY OTHERS)
EXTERIOR PANEL
W.PPOWER SUPPLY
F。
W.P
R1
R2
FINISHEDFLOOR
200
G
E
GUARD AT CEILING
MIN
.230
0
C
50
600
AB50
Part Standard OptionControl TypeStepCombSkirt GuardFloorLubricationEntry Box
PLCSTS StepPlasticSteel Plate Painting with Black ColorSTSAuto LubricationSteel Plate Bended with Black Color Painting
Micom Controller, VVVF ControllerAL StepAluminumSTS SkirtAluminum FloorAuto LubricationSTS Bended
Specification
Dimensions
No. ofFlat Step
Angle ofInclination
Rise(H) TypeStepWidth
BA C D E F G J K M
2
30。 2050
~
6000
600 604 29152145 1865 1595
800 950 1020 1100
30 2300
2220 1940 1670 35 2000
29152415299029902490
8001000600800
1000
80410046048041004
35。
[Note]- When L is over (30 * : 15500, 35 * : 13800)mm, an immediate support is required.(In case of EN115 compliance, L is 15,553mm) - For no intermediate support and when L is over (30 * : 15500, 35 * : 13800)mm, consult SIGMA for further details.- Given dimensions may change without prior notice.
(units : kg)Reaction
No. ofFlat Step
Angle ofInclination
600 Type
R1
230。 0.64H+2500 0.64H+1900
0.52H+2800 0.52H+23000.80H+3100 0.80H+25000.67H+3400 0.67H+270035。
R2
800 & 1000 Type
R1 R2
Electric Data
No. ofFlat Step
Angle ofInclination
Type
230。
35。
Motor (kW)Power Source Lead In Wire (mm2)
MCCB Capacity Of Building (A)
600 ≤5.0m800 & 1000 ≤3.85m
600 ≤5.0m800 & 1000 ≤3.7m
5.54
25
≤6.0m -≤5.15m ≤6.0m≤6.0m -≤5.0m
7.55.535
≤6.0m9.58
45
Rise H(m)
No. ofFlat Step
Angle ofInclination
Type W W1 W2 W3
30。/ 35。2600
800
1000
609
809
1009
820
1020
1220
1150
1350
1550
1250
1450
1650
(units : mm)
(units : mm)
(Based on 400V)
Rise(H)
2050~
6000
“Y” Detail (Steel structure) “Y” Detail (Concrete structure)
12 13
Layout & Technical Data
“Y” Detail (Steel structure) “Y” Detail (Concrete structure)
Layout (Rise: 6050mm ~ 8400mm) Technical Data (Rise 6050mm~8400mm)
Dimensions
No. ofFlat Step
Angle ofInclination
Rise (H) CBStepWidth
Type D E G J K
30。3 6050~8400600 604800 8041000 1004
2556 2390 2006 800 950 1100 1180
- Maximum N, M dimension should be less than 13,000mm.
A
344034402940
Electric Data
No. ofFlat Step
Angle ofInclination
Type
30。3
Motor (kW)Power Source Lead In Wire (mm2)
MCCB Capacity Of Building (A)
600 6050 ≤ H ≤ 8400800 & 1000 -
9.58
45
-6050 ≤ H ≤ 7800
118
50
-7850 ≤ H ≤ 8400
131460
Rise H(mm)
(units : mm)
No. ofFlat Step
Angle ofInclination
Rise (H) W3W2W1Type W
30。3 6050~8400600800
1000
6098091009
82010201220
115013501550
125014501650
(units : mm)
Part Standard OptionControl TypeStepCombSkirt GuardFloorLubricationEntry Box
PLCSTS StepPlasticSteel Plate Painting with Black ColorSTSAuto LubricationSteel Plate Bended with Black Color Painting
Micom Controller, VVVF ControllerAL StepAluminumSTS SkirtAluminum FloorAuto LubricationSTS Bended
Specification
(Based on 400V)
FINISHEDFLOOR
(units : kg)Reaction
No. ofFlat Step
Angle ofInclination
3 30。6050 ~ 6500 0.47M+15006550 ~ 8400 0.47M+2100
0.47N+800 0.47(M+N)+15000.47N+1100 0.47(M+N)+1500
R1
600 & 800 & 1000 Type
R2 R3Rise (H)
14
SIGMA Moving Walk keeps you on the move...
MOVING WALK
15
Modern “Moving Walk”-Creating a pleasant buildingculture in many countries around the world
Where SIGMA Moving Walk keeps you on the move :
Airport / Shopping Center / Subway Station / Railway Station / Hospital /
Exhibition Center / Museum / Amusement Park etc.,
How SIGMA Moving Walk keeps you on the move :
Convenient / Smooth / Reliable / Safe
SKIRT GUARD
COMB PLATE
PALLET
INSIDE DECK HANDRAIL
GLASS PANEL
DEMARCATION LINES
COMB
COVER PLATE
OUTSIDE DECK
SCT Model
15
Safety Devices
1 Emergency Stop Button If pressed in an emergency, stops the moving walk immediately.
2 Comb Plate Safety Switch Stops if objects are caught between comb plate and pallet treads.
3 Pallet Chain Safety Device Stops if the pallet chain breaks or becomes loose.
4 Handrail Inlet Safety Device Stops if hand or object is pulled into the handrail inlet.
5 Driving Chain Safety Device Stops if the driving chain breaks or excessively looses.
6 Maintenance Switch Cuts off operating circuits when maintenance inspection or repairis performed.
7 Green Light Green light lamps are provided below the flat pallet at both landings.
8 Non Reversing Safety Device Stops if its direction of thravel is reversed.
9 Skirt Guard Safety Device Stops if objects are caught between allet skirts.
10 Handrail Speed monitoring Device Stops if handail speed is below normal due to handrail breakage or elongation.
11 Over Speed Detector Stops if operating above normal speed.
12 Prevents static electricity with handrail running loop installed blocking static
electricty.
Handrail Static Electricity
Preventer
●
●
●
●
●
●
●
●
●
□
●
□
●
●
●
●
●
●
●
●
●
□
●
□
Safety Devices SCT SETDescription
●Standard □Option
16 17
Service Factor for Support loads
T P Q
Dimensions
ModelAngle of
InclinationRise(H) C D E G J KAType B
80010008001000
2790229028902390
2290
23901960 1960 843 760
1040
1080
1120
1160
Reaction
No. of Support R1 R2 R3 R43 (L1+L2)×T+P
L1×T+P
L3×T+Q
L3×T+Q
0.459 1122.5 510
-
(L1+L2)×1.35×T4
(L1+L2+L3)×1.35×T
(L2+L3)×1.35×T
(units : kg)
SCT & SET Model (Rise: 2500mm ~ 7000mm)
(units : mm)
Specification & Construction
Technical Data for SCT & SET Model (Rise 2500mm~7000mm)
Part Description
Balustrade
Floor
Pallets
Handrail Synthetic Rubber
AluminiumGlassAluminium / GrayStainless Steel (Standard) / Aluminium (Option)Stainless Steel (Standard) / Aluminium (Option)Stainless Steel (Standard) / Aluminium (Option)Without
Handrail FramePanelComb
Comb PlateCover Plate
PalletDemarcation Line
Specification
Type 1000 Type
1200mmEffective Width
Pallet WidthSpeed
GradientMotor
Operation
1004mm30m/min
Slope type : 12。AC Three-phase induction motor
Reversible key switch
SCT12
/SET1212。
2500~6000
6050~7000
ModelAngle of
InclinationRise(H) W2 W3WType W1
8001000800
1000
81410148141014
1026122610261226
1356155613561556
1456165614561656
SCT12
/SET1212。
2500~6000
6050~7000
Electric Data
Model Type800
1000SCT/SET
Motor (kW)Power Source Lead In Wire (mm2)
MCCB Capacity Of Building (A)
H ≤ 3500H ≤ 2850
5.5425
H ≤ 5400H ≤ 4400
85.535
H ≤ 7000H ≤ 6250
118
50
-H ≤ 7000
131460
Rise H(mm)
18
Works By Others
Building Construction
Electrical Wiring
1 Cutting and patching of any holes needed to install the escalator / moving walk
2 Providing bases and supports for installation
3 Providing clear access to well ways
4 Providing a pit and moisture proofing at the lower end of escalator / moving walk
(If there are rooms occupied below this level, the pit must be of fire-resistant construction)
5 Finishing the floor and ceiling around the escalator / moving walk after installation
6 Installation of safety railings around the escalator / moving walk
7 Installation of exterior truss panels or other external decoration
8 Installation of delta guard at all intersections either between escalator / moving walk and ceiling
9 Installation of barriers and safety railings in the space between paired escalator / moving walk
10 Finishing ceiling edges, etc., around wells
11 Installation of safety net in the ceiling space, if required
12 Providing clear access for equipment and all necessary building renovation work for existing buildings
where escalator / moving walk are to be installed
13 Providing proper finish works for existing building installations
14 Proper safety protection, within 500mm from the handrail out side and 2,100mm from flooring, against any
columns or open ceilings, etc.
15 Any connection works for interfaces with building’s fire emergency protocols
No. Works by Others
16 Installation of power line wiring to the upper machine room
17 Installation of maintenance line wiring to upper machine room
18 Installation of earth(ground) lines to upper machine room
19 Installation of power supply and switches for lighting
20 Installation of building equipment such as sprinkler system, public address systems and signs
21 Installation of power supply and switches for lighting in lower ends
22 Installation of 4 non-Voltage lines(2 upper, 2 lower) for fire shutters
No. Works by Others
Arrangement Type
Arrangements
[Single] [Parallel]
[Scissors] [Double Scissors]
[Criss Cross]
[Note]
These pictures are for Arrangement Type of Escalator.
Also, Arrangement Type of Moving walk is the same as well.
19