0405 097 553 www.alldd.com.auQBSA Lic. 1084590
ArchitecturalBuilding DesignResidentialCommercialRenovations
all design
and
draf
ting
THIS DRAWING IS THE COPYRIGHT AND PROPERTY OF ALL DESIGN AND DRAFTING. IT IS NOT TO BE COPIED, RETAINEDOR USED FOR ANOTHER PURPOSE. ALL NON SPECIFIED MATERIALS, COLOURS, FINISHES,FURNITURE,VEHICLES, DOOR ANDWINDOW OPERATION AND LANDSCAPING ARE FOR PRESENTATION PURPOSED ONLY.
C
NEW 10 UNIT DEVELOPMENT FORCALEZAC PTY.LTD5 KAURI STREET, COOROY QBCC
DRAWING LIST
BA00 COVER SHEETBA01 OVERALL SITE PLANBA02 LOT 10 SITE PLANBA03 LOT 11 SITE PLANBA04 SITE ELEVATIONS 1BA05 SITE ELEVATIONS 2BA06 UNIT TYPE A FLOOR & ROOF PLANBA07 UNIT TYPE A ELEVATIONSBA08 UNIT TYPE A ELECTRICAL PLANBA09 UNIT TYPE B FLOOR & ROOF PLANSBA10 UNIT TYPE B ELEVATIONSBA11 UNIT TYPE B ELECTRICAL PLANBA12 UNIT TYPE C FLOOR & ROOF PLANSBA13 UNIT TYPE C ELEVATIONSBA14 UNIT TYPE C ELECTRICAL PLANBA15 TYPICAL SECTIONS, DETAILS AND SPECIFICATION
3000
UNIT 1TYPE A
UNIT 2TYPE C
UNIT 3TYPE C
UNIT 4TYPE C
UNIT 5TYPE C
UNIT 6TYPE A
UNIT 7TYPE B
UNIT 8TYPE C
UNIT 9TYPE C
UNIT 10TYPE C
Boundary 76.44 m
Boun
dary
26.5
0 m
LOT 10 AREA 2026sqmSITE COVER 38%
LOT 11 AREA 2026sqmSITE COVER 37%
EXISTING LOT 22 AREA TOTAL 4052sqm
Boundary 76.44 m
Boundary 76.44 m
Boun
dary
26.5
0 m
KAU
RI S
TREE
T
EXISTING SEWER
PROPOSED RELOCATED SEWER & 3m EASEMENT
PROP
OSED
NEW
CRO
SSIN
GPR
OPOS
ED N
EW C
ROSS
ING
3000
3000
6300
7000
3000
6300
7000
3000
6300
6300
4900
2600
4900
4900
2500 2500
7304
6854
OM
P
6854
OM
P
7304
6854
OM
P
7304
7304 6854
6854
OM
P
7304
6854
OM
P
7304
6854
OM
P
7304
6854
OM
P
7304
6854
OM
P
7304
6854
OM
P
7304
5550 OMP
6000
5550 OMP
6000
OM
P
1550 2000 33
85 3840
OM
P
1550 2000
OM
P
1550 2000
OM
P
1550 2000
5550 OMP
6000
5550 OMP
6000
OM
P
1550 2000
1550 2000
OM
P
1550 2000
OM
P
1550 2000
2000
OM
P
1550
OMP
2520
3420
OMP
3234
4134
OMP
2520
3420
OMP
2520
3420
OMP
2520
3420
OMP
3124
4024
OMP
2520
3420
OMP
2520
3420
4900
2600
4900
2500 2500
4900
s
NORTH
w e
NEW CROSSINGTO COUNCILSTD PLANS
NEW CROSSINGTO COUNCILSTD PLANS
LETTER BOX BANK
LETTER BOX BANK
0405 097 553 www.alldd.com.auQBSA Lic. 1084590
ArchitecturalBuilding DesignResidentialCommercialRenovations
all design
and
draf
ting
Scale
Date
Project number
THIS DRAWING IS THECOPYRIGHT AND PROPOERTY OFALL DESIGN AND DRAFTING. IT ISNOT TO BE COPIED, RETAINED ORUSED FOR ANOTHER PURPOSE.
CClient:
Project:
Address:
Property Details:
CALEZAC PTY LTD
MULTI HOUSINGDEVELOPMENT
LOT 10 & 11KAURI STREET COOROYQLD 4563
PROPOSED LOT 10RECONFIGURATION OF LOT 22 ON C56016 Drawing no.
Issue Details:
06-11-2015
11489
Development Application10 11/04/2015
Amendments11 12/11/2015
Pre BA12 06/11/2015
QBCCPre BA13 15/12/2015
Pre BA14 16/12/2015
Pre BA15 27/01/2016
OVERALL SITE PLAN
BA011:250 (A3)
118.0 123.0 122.0
122.0 121.0 121.0
120.0
120.0
119.0
117.0
116.0
115.0
115.0
116.0 11
7.0
118.0
11
8.0
119
.0
120.0
120.0
121.0 121.0
122.0
119.0
2
BA04
PROPOSED SEWER
EXISTING SEWER
PROPOSED 3m EASEMENT
UNIT 1TYPE A
UNIT 2TYPE C
UNIT 3TYPE C
UNIT 4TYPE C
UNIT 5TYPE C
1
BA04
1
BA052
BA05
PATH
DECK
PATH
PATH
PATH
PATH
PATH
PATH
PATH
PATH
PATH
DECK DECK DECKDECK
PATH
s
NORTH
w e
122.06 FFL121.46 FFL 120.46 FFL
119.35 FFL118.13 FFL
Boundary 76.44 m
Boun
dary
26.5
0 m
Boundary 76.44 m
Boun
dary
26.5
0 m
RL 119.35 RL 118.13RL 118.13RL 119.35RL 120.46RL 120.46RL 121.46RL 121.46RL 122.06RL 122.06 121.21
121.21
120.71
120.71
120.21
120.21
119.60
119.60
119.10
119.10
118.38
118.38
1:20
2000 2000 2000
1:9 1:20
7590OR 1:10
2000 2000 2000 2000 2000
1:8 1:5.19 1:8 1:8 1:5.9 1:8 1:8 1:5 1:8
8304OR 1:8.2
NOTE:ALL CONTOUR LINES REPRESENT EXISTING LEVELSALL RL'S REPRESENT PROPOSED LEVELS
EXTENT OF POSSIBLE RETAINING MAXIMUMPROPOSED HEIGHT 1.2m.
R
R R R R
I
I
GPGPGP
STORMWATER LEGENDGP GROSS POLLUTANT TRAPI ON SITE SILT TRAP, INFILTRATION &
OVERFLOW SYSTEMR RAINWATER DETENTION TANK UNDER EACH
DWELLING WITH SLOW LEAK ORIFICE, EST.TANK 10,000L PER UNIT
SEE ENGINEERING DRAWINGS FOR DETAILS
EXISTING SEWER MHNEW SEWER MH
NEW SEWER MH
FRONT FENCESETBACK AVERAGEOF 1m ANDARTICULATED ATMAX 5m INTERVALS1.8m SELECTEDPOOL SYLE FENCE
AREA BETWEENBOUNDARY &FENCE DENSELYLANSCAPED
GATE
GATE
F2F2F2
F2 F2 F2
F2F2
F2F2
F1F1
F1
F1
F1
F1
F1
F3 F3 F3F3
GATE GATE GATE
GATE
GATE
2.5m
x 4
.9m
CO
NC
RET
EVI
SITO
RC
ARPA
RK
2.6m
x 4
.9m
CO
NC
RET
ETU
RN
ING
BAY
CONCRETETURNINGBAY
2.5m
x 4
.9m
CO
NC
RET
EVI
SITO
RC
ARPA
RK
F1 FENCE TYPE 11.8m HIGH SELECTED POOL STYLE
F2 FENCE TYPE 21.8m COLOURBOND FENCE
F3 1.8m TIMBER SLAT PRIVACY SCREEN FENCE
FENCE LEGEND
0405 097 553 www.alldd.com.auQBSA Lic. 1084590
ArchitecturalBuilding DesignResidentialCommercialRenovations
all design
and
draf
ting
Scale
Date
Project number
THIS DRAWING IS THECOPYRIGHT AND PROPOERTY OFALL DESIGN AND DRAFTING. IT ISNOT TO BE COPIED, RETAINED ORUSED FOR ANOTHER PURPOSE.
CClient:
Project:
Address:
Property Details:
CALEZAC PTY LTD
MULTI HOUSINGDEVELOPMENT
LOT 10 & 11KAURI STREET COOROYQLD 4563
PROPOSED LOT 10RECONFIGURATION OF LOT 22 ON C56016 Drawing no.
Issue Details:
06-11-2015
11489
Development Application10 11/04/2015
Amendments11 12/11/2015
Pre BA12 06/11/2015
QBCCPre BA13 15/12/2015
Pre BA14 16/12/2015
Pre BA15 27/01/2016
LOT 10 SITE PLAN
BA02
1 : 200
SITE PLANLOT 101
1:200 (A3)
118.0
114
115.0
118.0
118.0
117.0 117.0
116.0
11
6.0
115.0 115.0
114.0 114.0
113.0 113.0
112.0
112.0
113.0
114.0
114.0
115.0
116.0 117.0 118.0
11
8.0
119
.0
120.0 120.0
119.0 119.0
118.0 118.0
s
NORTH
w e2.
5m x
4.9
mC
ON
CR
ETE
VISI
TOR
CAR
PAR
K
2.6m
x 4
.9m
CO
NC
RET
ETU
RN
ING
BAY
CONCRETETURNINGBAY
UNIT 6TYPE A
UNIT 7TYPE B
UNIT 8TYPE C
UNIT 9TYPE C
UNIT 10TYPE C
3
BA04
3
BA05
IL 114.08@ MH
115.38 FFL115.85 FFL116.56 FFL
PROPOSED SEWEREXISTING SEWER
PROPOSED 3m EASEMENT
1
BA052
BA05
PATH
DECK
PATH
PATH
PATH PA
TH
PATH
PATH
PATH
PATH
DECK DECK DECK
DECK
118.31 FFL
119.51 FFL
Boundary 76.44 m
Boun
dary
26.5
0 m
Boundary 76.44 m
Boun
dary
26.5
0 m
RL 119.51 RL 118.31RL 118.44
RL 118.31 RL 118.32RL 119.51 RL 119.51 RL 116.56RL 116.56
RL 115.85
RL 115.85RL 115.85
RL 115.38 RL 115.38
RL 115.38 RL 115.38RL 119.26
RL 119.26 RL 118.56
RL 118.56RL 118.12
RL 118.12RL 116.75
RL 116.75 RL 116.31
RL 116.31 RL 116.10
RL 116.10 RL 115.75
RL 115.75
115.48
115.48
2000 2000 2000 2000 2000 2000
1:8
1:8
1:5.14 1:8 1:8 1:3.9 1:8 1:8 1:17 1:8 1:20 1:13.3 1:20
NOTE:ALL CONTOUR LINES REPRESENT EXISTING LEVELSALL RL'S REPRESENT PROPOSED LEVELS
EXTENT OF POSSIBLE RETAINING MAXIMUMPROPOSED HEIGHT 1.2m.
R
R
R R R
I
I
GPGPGP
STORMWATER LEGENDGP GROSS POLLUTANT TRAPI ON SITE SILT TRAP, INFILTRATION &
OVERFLOW SYSTEMR RAINWATER DETENTION TANK UNDER EACH
DWELLING WITH SLOW LEAK ORIFICE, EST.TANK CAP 5,000L - 10,000L PER UNIT
EXISTING MH
NEW SEWER MHIL 144.455
FRONT FENCESETBACK AVERAGEOF 1m ANDARTICULATED ATMAX 5m INTERVALS
AREA BETWEENBOUNDARY &FENCE DENSELYLANSCAPED
GATE
GATE
F2F2F2
F2 F2 F2
F2F2
F2
F2
F1F1
F1
F1
F1
F1
F3 F3 F3F3
CONCRETEDRIVE
EASEMENT
3000
2.5m
x 4
.9m
CO
NC
RET
EVI
SITO
RC
ARPA
RK
GATE GATE GATE GATE
F1 FENCE TYPE 11.8m HIGH SELECTED POOL STYLE
F2 FENCE TYPE 21.8m COLOURBOND FENCE
F3 1.8m TIMBER SLAT PRIVACY SCREEN FENCE
FENCE LEGEND
0405 097 553 www.alldd.com.auQBSA Lic. 1084590
ArchitecturalBuilding DesignResidentialCommercialRenovations
all design
and
draf
ting
Scale
Date
Project number
THIS DRAWING IS THECOPYRIGHT AND PROPOERTY OFALL DESIGN AND DRAFTING. IT ISNOT TO BE COPIED, RETAINED ORUSED FOR ANOTHER PURPOSE.
CClient:
Project:
Address:
Property Details:
CALEZAC PTY LTD
MULTI HOUSINGDEVELOPMENT
LOT 10 & 11KAURI STREET COOROYQLD 4563
PROPOSED LOT 10RECONFIGURATION OF LOT 22 ON C56016 Drawing no.
Issue Details:
06-11-2015
11489
Development Application10 11/04/2015
Amendments11 12/11/2015
Pre BA12 06/11/2015
QBCCPre BA13 15/12/2015
Pre BA14 16/12/2015
Pre BA15 27/01/2016
LOT 11 SITE PLAN
BA03
1 : 200
SITE PLANLOT 111
1:200 (A3)
1220
1107
1000
598
6000
BOU
ND
ARY
BOU
ND
ARY
6000
UNIT 1UNIT 2
UNIT 3
UNIT 4
UNIT 5
NGL
118.13 FFL
122.06 FFL
NATURAL GLPROPOSED GL
PRELIMINARY 115.06 FFLPRELIMINARY 115.53 FFL
PRELIMINARY 116.24 FFL
BOU
ND
ARY
BOU
ND
ARY
6000
UNIT 1UNIT 2
UNIT 3
UNIT 4
UNIT 5
UNIT 6UNIT 7
UNIT 8
UNIT 9
UNIT 10
2686
1717
2333
288725
05
PRELIMINARY 117.99 FFL
RAINWATER TANK & 12.6m3WEATHERPROOF STORAGE AREAIN UNDERCROFT
NATURAL GLPROPOSED GL
BOU
ND
ARY
BOU
ND
ARY
6000
UNIT 1UNIT 2
UNIT 3
UNIT 4
UNIT 5
2980
2980
2980
264725
27
NATURAL GL
PROPOSED GL
0405 097 553 www.alldd.com.auQBSA Lic. 1084590
ArchitecturalBuilding DesignResidentialCommercialRenovations
all design
and
draf
ting
Scale
Date
Project number
THIS DRAWING IS THECOPYRIGHT AND PROPOERTY OFALL DESIGN AND DRAFTING. IT ISNOT TO BE COPIED, RETAINED ORUSED FOR ANOTHER PURPOSE.
CClient:
Project:
Address:
Property Details:
CALEZAC PTY LTD
MULTI HOUSINGDEVELOPMENT
LOT 10 & 11KAURI STREET COOROYQLD 4563
PROPOSED LOT 10RECONFIGURATION OF LOT 22 ON C56016 Drawing no.
Issue Details:
06-11-2015
11489
Development Application10 11/04/2015
Amendments11 12/11/2015
Pre BA12 06/11/2015
QBCCPre BA13 15/12/2015
Pre BA14 16/12/2015
Pre BA15 27/01/2016
SITE ELEVATIONS 1
BA04
1 : 200
LOT 10NORTHELEVATION
1
1 : 200
LOT 11SOUTHELEVATION
3
1 : 200
LOT 10SOUTHELEVATION
2
1:200 (A3)
2160
BOU
ND
ARY
2230
BOU
ND
ARY
BOU
ND
ARY
7144
2899
LOT 11
LOT 10
2980
UNIT 1UNIT 2UNIT 3UNIT 4UNIT 5
UNIT 6UNIT 7UNIT 8UNIT 9UNIT 10
7144
NATURAL GLPROPOSED GL
BOU
ND
ARY
BOU
ND
ARY
1684
BOU
ND
ARY
1684121.74 FFL
119.51 FFL
NATURAL GLPROPOSED GL
470
705 17
55
1195BO
UN
DAR
Y
6000
BOU
ND
ARY
6000
UNIT 6
UNIT 7
UNIT 8
UNIT 9UNIT 10
115.38 FFL
116.56 FFL
118.31 FFL
119.51 FFL
115.85 FFL
NATURAL GL
PROPOSED GL
0405 097 553 www.alldd.com.auQBSA Lic. 1084590
ArchitecturalBuilding DesignResidentialCommercialRenovations
all design
and
draf
ting
Scale
Date
Project number
THIS DRAWING IS THECOPYRIGHT AND PROPOERTY OFALL DESIGN AND DRAFTING. IT ISNOT TO BE COPIED, RETAINED ORUSED FOR ANOTHER PURPOSE.
CClient:
Project:
Address:
Property Details:
CALEZAC PTY LTD
MULTI HOUSINGDEVELOPMENT
LOT 10 & 11KAURI STREET COOROYQLD 4563
PROPOSED LOT 10RECONFIGURATION OF LOT 22 ON C56016 Drawing no.
Issue Details:
06-11-2015
11489
Development Application10 11/04/2015
Amendments11 12/11/2015
Pre BA12 06/11/2015
QBCCPre BA13 15/12/2015
Pre BA14 16/12/2015
Pre BA15 27/01/2016
SITE ELEVATIONS 2
BA05
1 : 200
EASTELEVATION1
1 : 200
KAURISTEETELEVATION
2
1 : 200
LOT 11NORTHELEVATION
3
1:200 (A3)
TOTAL FLOOR AREA 149sqmSE
RVI
CE
CO
UR
T
4
BA07
AUTO PANEL LIFT
2115
SD
0906
SW
0912
SW
1224SW
GARAGE
L'D
RY
ENTRY
DINING
LIVING
BATH
RM
RO
BE
ENSU
ITE
STUDYBEDRM 2
BEDRM 1
KITC
HEN
DECK
1
BA07
2
BA07
3
BA07
PATH
s
NORTH
w e
2106
DH
2106
DH
TIM
870
870 CS
2127
STAC
KER
2118SD
2106
DH
2106
DH
1224
SW
2115SD
0321FG
2/620 CS870
870
2/ 5
20
2/ 5
20
0621
SW
870
820
870
470
FR
CEHS
DW
B
SHW
GLASS SCREEN
WHB
WC
FW
FW
FW
ROBE
STOR
E
L
OHCUP
WMDP
DP
DPDP
DP
DP
WC
SHWGLASS SCREEN& DOOR
WHB
TIMPOST
TIMPOST
TIMPOST
ALUMINIUM ANDOBS GLASSBALUSTRADE1000mm HIGH
SELECTED FLOORING
CARPET
CARPETCARPET
CONCRETE
TILE
TILE
SELE
CTED
FIN
ISH
SELE
CTED
FIN
ISH
0 STEP0 STEP
0 STEP
0 STEP
10010
70 5700 70 1600 70 2430 70
7510 2500
60070 6070 70 700 2500
70 3000 70 530 70 3000 70 1530 70 1530 70
70 2000 70 4600 70 3130 70
6740 70 3130 70
2225
1720
0
6140
1530
9530
7029
3070
2425
7038
9570
1530
7060
70
6070
7079
9070
530
7011
2070
1140
70
4210
1860
4720
6410
7027
0070
3500
7046
5019
40
7029
3070
7990
7018
0070
2180
7024
0070
0 STEP
S
OBS
OBS
DP
DP
DPDP
DP
DP
20°
20°
20°
20°
20°
20°
RIDG
E
RIDG
E
VALLEY
HIPHIP
HIP
HIP
HIP
HIP
WHIRLYBIRD
SOLAR PANELS TBC
COLOURBOND CUSTOMORB ROOF SHEETING,FIXED TO MANUFACTURERS SPECIFICATIONSON PREFABRICATED TIMBER ROOF TRUSSES ,INSULATION AS PER STAR ENERGY RATING
COLOURBOND ROOFING,GUTTERS AND FASCIA
450
450
450
450
450
PANPANTRYFR FRIDGE SPACEC COOKEREH EXTRACT HOODS SINKDW DISHWASHER SPACEB BATHWHB WASH HAND BASINSHW SHOWERWC TOILETFW FLOOR WASTEROBE WARDROBEWIRWALK IN ROBELINENLINEN CUPBOARDOHCUP OVER HEAD CUPBOARDWM WASHING MACHINED DRYERDP DOWNPIPEDPSP DOWNPIPE WITH SPREADERSD SLIDING DOORSTACK STACKER DOORBIBIFOLDCS CAVITY SLIDING DOORSW SLIDING WINDOWFG FIXED GLASSDH DOUBLE HUNG WINDOWAW AWINING WINDOWCW CASEMENT WINDOWLVRLOUVRE WINDOWOBS OBSCURE GLASSTBC TO BE CONFIRMEDCOS CHECK ON SITEOMP OUTER MOST PROJECTIONTIM TIMBERFESFIXED EXTERNAL SCREENSLS LANDSCAPING
LEGEND
1. LIFT OFF DOOR TO BE FITTED TO WC.2. SMOKE ALARMS TO COMPLY WITH BCA
CLASS 1 & 10 PART 3.7.2 AND WITH AS3786.
3. TERMITE TREATMENT TO AS 3660.1,1-2000 & BCA VOL 2 PART 3.1.3 GRADEDSTONE TO EXTERNAL WALL CAVITY ANDCOLLARS (IN ACCORDANCE WITH AS) TOALL SLAB PENETRATIONS. TERMITESTICKER TO BE IN METERBOX IN VISIBLEPOSITION.
4. ALL HANDRAILS TO 1000mm HIGH AND TOCOMPLY WITH THE REQUIREMENTS OFBCA AND ANY LOCAL REGULATIONS.HANDRAILS BOTH SIDES OF ALL STAIRS.
5. SEE SPECIFICATION FOR BEDROOMWINDOW SAFETY REQUIRMENTS.
6. ALL DIMENSIONS TO BE CHECKED ONSITE AND ANY DISCREPANCIESREPORTED TO THE DESIGNER.
7. THESE DRAWING SHALL BE READ INCONJUNCTION WITH THE ENGINEERSDOCUMENTS AND TOWN PLANNINGCONDITIONS OF PERMIT.
8. ALL WORK AND MATERIALS SHALL BE INACCORDANCE WITH THE DRAWINGS,SPECIFICATIONS AND CURRENTRELEVANT AUSTRALIAN STANDARD, THEBUILDING CODE OF AUSTRALIA ANDOTHER STATUTORY REQUIREMENTS.
9. ALL DIMENSIONS ARE IN MILLIMETERSUNLESS NOTED OTHERWISE.
10. ALL DOORS ARE 870mm WIDE TO ALLOW850mm OPENING AND ALL THRESHOLDSARE 0mm STEP TO COMPLY WITHAS4299-1995 ADAPTABLE HOUSING CODE.
GENERAL NOTES
0405 097 553 www.alldd.com.auQBSA Lic. 1084590
ArchitecturalBuilding DesignResidentialCommercialRenovations
all design
and
draf
ting
Scale
Date
Project number
THIS DRAWING IS THECOPYRIGHT AND PROPOERTY OFALL DESIGN AND DRAFTING. IT ISNOT TO BE COPIED, RETAINED ORUSED FOR ANOTHER PURPOSE.
CClient:
Project:
Address:
Property Details:
CALEZAC PTY LTD
MULTI HOUSINGDEVELOPMENT
LOT 10 & 11KAURI STREET COOROYQLD 4563
PROPOSED LOT 10RECONFIGURATION OF LOT 22 ON C56016 Drawing no.
Issue Details:
06-11-2015
11489
Development Application10 11/04/2015
Amendments11 12/11/2015
Pre BA12 06/11/2015
QBCCPre BA13 15/12/2015
Pre BA14 16/12/2015
Pre BA15 27/01/2016
UNIT TYPE A FLOOR & ROOFPLAN
BA06
1 : 100
UNIT TYPE AFLOOR PLAN1
1:100 (A3)
1 : 100
UNIT TYPE AROOF PLAN2
UNIT TYPE A
UNIT A INTERNAL FLOOR AREA 134 m²UNIT A SERVICE COURT 7 m²UNIT A DECK AREA 15 m²UNIT A PORCH 1 m²TOTAL GROSS FLOOR AREA 157 m²
2700
WCT 1
WCT 3
COLOURBOND ROOFING, GUTTERS AND FASCIAS
ALUMINIUM AND OBSGLASS BALUSTRADE1000mm H
COLOURBOND PANEL LIFT GARAGE DOOR
OPE
NING
S
2100
SELECTED SCREEN TO SERVICE COURT
SOLAR PANELS TBC
20.0
°
2700
WCT 2
WCT3 WCT 1
ALUMINIUM AND OBS GLASSBALUSTRADE 1000mm H
PROVIDE BALUSTRADE 1000mm HIN ALL LOCATIONS 1000mmABOVE GL
RAIN WATER TANK
OPE
NING
S
2100
COLOURBOND ROOFING, GUTTERS AND FASCIAS
20.0
°
TYPICAL ELEVATIONSGROUND LEVEL VARIES
2700
20.0
°WCT 2
PROVIDE BALUSTRADE 1000mm HIN ALL LOCATIONS 1000mmABOVE GL
RAIN WATER TANK
COLOURBOND ROOFING, GUTTERS AND FASCIAS
OPE
NING
S
2100
TYPICAL ELEVATIONSGROUND LEVEL VARIES
PROVIDE MIN. 12.6m3WEATHERPROOF STORAGE AREAIN UNDERCROFT
2700
PROVIDE BALUSTRADE 1000mm HIN ALL LOCATIONS 1000mmABOVE GL
COLOURBOND ROOFING, GUTTERS AND FASCIAS
WCT 2
WCT 3
WCT 3
SELECTED ENTRANCE DOORSLIDING WINDOW
OPE
NING
S
2100
1500
20.0
°
TYPICAL ELEVATIONSGROUND LEVEL VARIES
WALL CLADDING LEGEND
WCT 1 COLOURBOND CUSTOM ORB VERTICAL CLADDING
WCT2 TBCCEMINTEL EDGE (DIRECT FIX, NOT PREFINISHED)150mm VERTICAL
WCT3 TBCCEMINTEL SMOOTH (TOP HAT FIXING, PREFINSHED) ORCEMINTEL ASPECT (DIRECT FIX, NOT PREFINISHED)12mm X 300mm HORIZONTAL
0405 097 553 www.alldd.com.auQBSA Lic. 1084590
ArchitecturalBuilding DesignResidentialCommercialRenovations
all design
and
draf
ting
Scale
Date
Project number
THIS DRAWING IS THECOPYRIGHT AND PROPOERTY OFALL DESIGN AND DRAFTING. IT ISNOT TO BE COPIED, RETAINED ORUSED FOR ANOTHER PURPOSE.
CClient:
Project:
Address:
Property Details:
CALEZAC PTY LTD
MULTI HOUSINGDEVELOPMENT
LOT 10 & 11KAURI STREET COOROYQLD 4563
PROPOSED LOT 10RECONFIGURATION OF LOT 22 ON C56016 Drawing no.
Issue Details:
06-11-2015
11489
Development Application10 11/04/2015
Amendments11 12/11/2015
Pre BA12 06/11/2015
QBCCPre BA13 15/12/2015
Pre BA14 16/12/2015
Pre BA15 27/01/2016
UNIT TYPE A ELEVATIONS
BA07
1 : 100
TYPE AFRONT1
1 : 100
TYPE A LEFT2
1 : 100
TYPE AREAR3
1 : 100
TYPE ARIGHT4
S
METERBOARD
SMOKE DETECTOR
WALL LIGHT
CEILING LIGHT
CEILING FAN
LCEILING FAN WITH LIGHT
SINGLE POWER POINT GPO
DOUBLE POWER POINT GPO
SOLAR SWITCH BOARD
HOT WATER SYSTEM
AC AIRCONDITIONING UNIT
EXHAUST FANE
EXHAUST FAN HEATER LIGHTFHL
PHONE & OR DATA
TV
P
TV POINT
LEGEND
NOTES:1. 80% OF FLOOR AREA TO FITTED WITH ENERGYEFFICIENT LIGHTING TO COMPLY WITH CURRENTREQUIRED STAR RATING.2. ALL EXTRACT FANS TO BE DUCTED ANDDISCHARGED TO OPEN AIR.3. ALL FITTINGS SHOWN ARE GENERIC ONLY,FITTINGS TO BE SELECTED BY OWNER.4. ALL ELECTRICAL WORK TO BE DONE BYAPPROPRIATELY QUALIFIED PERSONS TO RELEVANTCODES AND STANDARDS.5. DIMMER LOCATIONS SHOWN ON PLANS MAY NOTBE SUITABLE FOR FITTINGS SELECTED.6. GPO TYPICALLY 300mm ABOVE FFL7. SWITCHES TYPICALLY 1100mm ABOVE FFL8. SMOKE ALARMS TO COMPLY WITH NCC F3.7.2DESIGN OF SMOKE ALARMS MUST COMPLY WITH AS3786. A CERTIFICATE OF INSTALLATION FORM ALICENCE ELECTRICAL CONTRACTOR IS REQUIRED ATFINAL INSPECTION.
WIRING TO LIGHT SWITCH
DISHWASHER
COOKER
DW
C
DIMMER SWITCHD
LLFHL
FHL
E
AC
BELOW FLOOR
PPTVTV
DW
C
D
DS
S
0405 097 553 www.alldd.com.auQBSA Lic. 1084590
ArchitecturalBuilding DesignResidentialCommercialRenovations
all design
and
draf
ting
Scale
Date
Project number
THIS DRAWING IS THECOPYRIGHT AND PROPOERTY OFALL DESIGN AND DRAFTING. IT ISNOT TO BE COPIED, RETAINED ORUSED FOR ANOTHER PURPOSE.
CClient:
Project:
Address:
Property Details:
CALEZAC PTY LTD
MULTI HOUSINGDEVELOPMENT
LOT 10 & 11KAURI STREET COOROYQLD 4563
PROPOSED LOT 10RECONFIGURATION OF LOT 22 ON C56016 Drawing no.
Issue Details:
06-11-2015
11489
Development Application10 11/04/2015
Amendments11 12/11/2015
Pre BA12 06/11/2015
QBCCPre BA13 15/12/2015
Pre BA14 16/12/2015
Pre BA15 27/01/2016
UNIT TYPE A ELECTRICAL PLAN
BA08
SER
VIC
E C
OU
RT TOTAL FLOOR AREA 146sqm
AUTO PANEL LIFT
TIM870
2106DH
0906
SW
2127
STAC
KER
2106DH2106DH
0912
SW21
15SD
1224
SW12
24SW
2118SD
1224SW
0621
SW
OBS
GARAGE
ENTR
Y
RO
BE
ENSU
ITE
BEDRM 1
KITC
HEN
DINING
STUDY
LIVING
BATHRM
BEDRM 2
DECK
LAUNDRY
1
BA10
2
BA10
4
BA10
PROPOSED SEWER
DP DP
DP
DP
DP
TIMPOST
STORE
ROBE
0 STEP
0 STEP
0 STEP
0 STEP
ALUMINIUM ANDOBS GLASSBALUSTRADE1000mm HIGH
CONCRETE
CARPET
CARP
ET
CARPET
CARPET
SELECTED FLOORING
TILES
TILE
S
TILES
SELE
CTED
FIN
ISH
SELE
CTED
FIN
ISH
GLASSSCREEN &DOOR
GLASS SCREEN
SHW
WC
FW
WHB
SHW
BWHB WC
FW
S WM
S
FR
DW OH CUP
CEH
L
870
870
1800
2100
870 870
470
870CS
2/620 CS
PROPOSED EASEMENT
1010 3270
70 5700 70 1010 70 1530 70 1530 70
60070 3130 70 1900 70 1010 70 3130 70
3740 4280 2550
10570
450
70 3000 7053070 4210 70 2030 70450
60070 2470 3710 70 3130 70450
60070 3130 70 1900 70 1010 70 440 70 2620 70
1536
0
5310
3910
6140
7018
9570
1480
7070
7070
6600
70
1480
4080
9800
7027
0070
3220
7053
070
3000
7040
1070
4145
3070
7021
0070
3910
7060
0070
OBS
OBS
OBS
PANPANTRYFR FRIDGE SPACEC COOKEREH EXTRACT HOODS SINKDW DISHWASHER SPACEB BATHWHB WASH HAND BASINSHW SHOWERWC TOILETFW FLOOR WASTEROBE WARDROBEWIRWALK IN ROBELINENLINEN CUPBOARDOHCUP OVER HEAD CUPBOARDWM WASHING MACHINED DRYERDP DOWNPIPEDPSP DOWNPIPE WITH SPREADERSD SLIDING DOORSTACK STACKER DOORBIBIFOLDCS CAVITY SLIDING DOORSW SLIDING WINDOWFG FIXED GLASSDH DOUBLE HUNG WINDOWAW AWINING WINDOWCW CASEMENT WINDOWLVRLOUVRE WINDOWOBS OBSCURE GLASSTBC TO BE CONFIRMEDCOS CHECK ON SITEOMP OUTER MOST PROJECTIONTIM TIMBERFESFIXED EXTERNAL SCREENSLS LANDSCAPING
LEGEND
1. LIFT OFF DOOR TO BE FITTED TO WC.2. SMOKE ALARMS TO COMPLY WITH BCA
CLASS 1 & 10 PART 3.7.2 AND WITH AS3786.
3. TERMITE TREATMENT TO AS 3660.1,1-2000 & BCA VOL 2 PART 3.1.3 GRADEDSTONE TO EXTERNAL WALL CAVITY ANDCOLLARS (IN ACCORDANCE WITH AS) TOALL SLAB PENETRATIONS. TERMITESTICKER TO BE IN METERBOX IN VISIBLEPOSITION.
4. ALL HANDRAILS TO 1000mm HIGH AND TOCOMPLY WITH THE REQUIREMENTS OFBCA AND ANY LOCAL REGULATIONS.HANDRAILS BOTH SIDES OF ALL STAIRS.
5. SEE SPECIFICATION FOR BEDROOMWINDOW SAFETY REQUIRMENTS.
6. ALL DIMENSIONS TO BE CHECKED ONSITE AND ANY DISCREPANCIESREPORTED TO THE DESIGNER.
7. THESE DRAWING SHALL BE READ INCONJUNCTION WITH THE ENGINEERSDOCUMENTS AND TOWN PLANNINGCONDITIONS OF PERMIT.
8. ALL WORK AND MATERIALS SHALL BE INACCORDANCE WITH THE DRAWINGS,SPECIFICATIONS AND CURRENTRELEVANT AUSTRALIAN STANDARD, THEBUILDING CODE OF AUSTRALIA ANDOTHER STATUTORY REQUIREMENTS.
9. ALL DIMENSIONS ARE IN MILLIMETERSUNLESS NOTED OTHERWISE.
10. ALL DOORS ARE 870mm WIDE TO ALLOW850mm OPENING AND ALL THRESHOLDSARE 0mm STEP TO COMPLY WITHAS4299-1995 ADAPTABLE HOUSING CODE.
GENERAL NOTES
SOLAR PANELS TBC
DP
DP
DP
DP
DP
20°
RIDG
E
VALLEY
HIP
WHIRLYBIRD
COLOURBOND CUSTOMORB ROOFSHEETING, FIXED TOMANUFACTURERS SPECIFICATIONS ONPREFABRICATED TIMBER ROOFTRUSSES , INSULATION AS PER STARENERGY RATING
COLOURBOND ROOFING,GUTTERS AND FASCIA
20°
20°
20°
20°
20°
RIDG
E
HIP
HIPHIP
HIP HIP
457
450
450
450
EAVE
450
NO EAVE EAVE
457
SLOPING GUTTER
EASEMENT
3000
SEW
ER
s
NORTH
w e
0405 097 553 www.alldd.com.auQBSA Lic. 1084590
ArchitecturalBuilding DesignResidentialCommercialRenovations
all design
and
draf
ting
Scale
Date
Project number
THIS DRAWING IS THECOPYRIGHT AND PROPOERTY OFALL DESIGN AND DRAFTING. IT ISNOT TO BE COPIED, RETAINED ORUSED FOR ANOTHER PURPOSE.
CClient:
Project:
Address:
Property Details:
CALEZAC PTY LTD
MULTI HOUSINGDEVELOPMENT
LOT 10 & 11KAURI STREET COOROYQLD 4563
PROPOSED LOT 10RECONFIGURATION OF LOT 22 ON C56016 Drawing no.
Issue Details:
06-11-2015
11489
Development Application10 11/04/2015
Amendments11 12/11/2015
Pre BA12 06/11/2015
QBCCPre BA13 15/12/2015
Pre BA14 16/12/2015
Pre BA15 27/01/2016
UNIT TYPE B FLOOR & ROOFPLANS
BA09
1 : 100
UNIT TYPE BFLOOR PLAN1
1:100 (A3)
1 : 100
UNIT TYPE BROOF PLAN2
UNIT TYPE B
UNIT B INTERTNAL FLOOR AREA 134 m²UNIT B PORCH 1 m²UNIT B DECK 10 m²UNIT B SERVICE COURT 2 m²TOTAL GROSS FLOOR AREA 148 m²
2700
OPE
NING
S
2100
COLOURBOND ROOFING, GUTTERS AND FASCIAS
20.0
°
COLOURBOND PANEL LIFT GARAGE DOORALUMINIUM AND OBSGLASS BALUSTRADE1000mm H
SOLAR PANELS TBCWCT 1
WCT 2
WCT 3
2700
OPE
NING
S
2100
NO EAVE
COLOURBOND ROOFING, GUTTERS AND FASCIAS
20.0
°
ALUMINIUM AND OBSGLASS BALUSTRADE1000mm H
WCT 2WCT 3
2700
OPE
NING
S
2100
NO EAVE
COLOURBOND ROOFING, GUTTERS AND FASCIAS20
.0°
ALUMINIUM AND OBSGLASS BALUSTRADE1000mm H
PROVIDE BALUSTRADE 1000mm HIN ALL LOCATIONS 1000mmABOVE GL
WCT 2WCT 3
PROVIDE MIN. 12.6m3WEATHERPROOFSTORAGE AREA INUNDERCROFT
2700
875 O
PENI
NGS
2100
COLOURBOND ROOFING, GUTTERS AND FASCIAS
20.0
°
SLIDING WINDOW OBS GLASS
WCT 1 WCT 2
WALL CLADDING LEGEND
WCT 1 COLOURBOND CUSTOM ORB VERTICAL CLADDING
WCT2 TBCCEMINTEL EDGE (DIRECT FIX, NOT PREFINISHED)150mm VERTICAL
WCT3 TBCCEMINTEL SMOOTH (TOP HAT FIXING, PREFINSHED) ORCEMINTEL ASPECT (DIRECT FIX, NOT PREFINISHED)12mm X 300mm HORIZONTAL
0405 097 553 www.alldd.com.auQBSA Lic. 1084590
ArchitecturalBuilding DesignResidentialCommercialRenovations
all design
and
draf
ting
Scale
Date
Project number
THIS DRAWING IS THECOPYRIGHT AND PROPOERTY OFALL DESIGN AND DRAFTING. IT ISNOT TO BE COPIED, RETAINED ORUSED FOR ANOTHER PURPOSE.
CClient:
Project:
Address:
Property Details:
CALEZAC PTY LTD
MULTI HOUSINGDEVELOPMENT
LOT 10 & 11KAURI STREET COOROYQLD 4563
PROPOSED LOT 10RECONFIGURATION OF LOT 22 ON C56016 Drawing no.
Issue Details:
06-11-2015
11489
Development Application10 11/04/2015
Amendments11 12/11/2015
Pre BA12 06/11/2015
QBCCPre BA13 15/12/2015
Pre BA14 16/12/2015
Pre BA15 27/01/2016
UNIT TYPE B ELEVATIONS
BA10
1 : 100
TYPE BFRONT1
1 : 100
TYPE B LEFT2
1 : 100
TYPE BREAR3 1 : 100
TYPE BRIGHT4
S
METERBOARD
SMOKE DETECTOR
WALL LIGHT
CEILING LIGHT
CEILING FAN
LCEILING FAN WITH LIGHT
SINGLE POWER POINT GPO
DOUBLE POWER POINT GPO
SOLAR SWITCH BOARD
HOT WATER SYSTEM
AC AIRCONDITIONING UNIT
EXHAUST FANE
EXHAUST FAN HEATER LIGHTFHL
PHONE & OR DATA
TV
P
TV POINT
LEGEND
NOTES:1. 80% OF FLOOR AREA TO FITTED WITH ENERGYEFFICIENT LIGHTING TO COMPLY WITH CURRENTREQUIRED STAR RATING.2. ALL EXTRACT FANS TO BE DUCTED ANDDISCHARGED TO OPEN AIR.3. ALL FITTINGS SHOWN ARE GENERIC ONLY,FITTINGS TO BE SELECTED BY OWNER.4. ALL ELECTRICAL WORK TO BE DONE BYAPPROPRIATELY QUALIFIED PERSONS TO RELEVANTCODES AND STANDARDS.5. DIMMER LOCATIONS SHOWN ON PLANS MAY NOTBE SUITABLE FOR FITTINGS SELECTED.6. GPO TYPICALLY 300mm ABOVE FFL7. SWITCHES TYPICALLY 1100mm ABOVE FFL8. SMOKE ALARMS TO COMPLY WITH NCC F3.7.2DESIGN OF SMOKE ALARMS MUST COMPLY WITH AS3786. A CERTIFICATE OF INSTALLATION FORM ALICENCE ELECTRICAL CONTRACTOR IS REQUIRED ATFINAL INSPECTION.
WIRING TO LIGHT SWITCH
DISHWASHER
COOKER
DW
C
DIMMER SWITCHD
BELOW FLOOR
L
L
FHL
FHL
E
DW
C
S
S
TV
TV
P
AC
0405 097 553 www.alldd.com.auQBSA Lic. 1084590
ArchitecturalBuilding DesignResidentialCommercialRenovations
all design
and
draf
ting
Scale
Date
Project number
THIS DRAWING IS THECOPYRIGHT AND PROPOERTY OFALL DESIGN AND DRAFTING. IT ISNOT TO BE COPIED, RETAINED ORUSED FOR ANOTHER PURPOSE.
CClient:
Project:
Address:
Property Details:
CALEZAC PTY LTD
MULTI HOUSINGDEVELOPMENT
LOT 10 & 11KAURI STREET COOROYQLD 4563
PROPOSED LOT 10RECONFIGURATION OF LOT 22 ON C56016 Drawing no.
Issue Details:
06-11-2015
11489
Development Application10 11/04/2015
Amendments11 12/11/2015
Pre BA12 06/11/2015
QBCCPre BA13 15/12/2015
Pre BA14 16/12/2015
Pre BA15 27/01/2016
UNIT TYPE B ELECTRICAL PLAN
BA11
2
BA13
4
BA13
TOTAL FLOOR AREA 149sqm
AUTO PANEL LIFT
2106
DH
0312FGTIM870
2106
DH
2127
STAC
KER
2106
DH
2106
DH
0906
SW
1224SW1224SW
0912
SW06
21 S
W O
BS21
15SD
2118SD
GARAGE
ENTR
Y
LAUNDRY
DECK
DINING
LIVING
KITC
HEN
BEDRM 1
BEDRM 2
BATH
RM
STUDY
RO
BE
ENSU
ITE
1
BA13
3
BA13
SER
VIC
E
DPDP
DP
DP
DP
DP
TIMPOST
TIMPOST
TIMPOST
L
STOR
ERO
BE
0 STEP
0 STEP
0 STEP
0 STEP
ALUMINIUM ANDOBS GLASSBALUSTRADE1000mm HIGH
CONCRETE
SELECTED FLOORING
SELE
CTED
FIN
ISH
SELE
CTED
FIN
ISH
CARPET
CARPET
CARPET
CARP
ET
TILE
TILE
TILE
GLASSSCREEN &DOOR
GLASS SCREENDW
FR
CEH
OH CUP
SHWB
WHB
FW
WC
WC
SHW
FW
WHB
SWM
870
870
870
4702/620 CS
870
2/520
2/520
870 870
s
NORTH
w e
5840 1570 2600
10010
70 3000 7053070 3000 70 1530 70 1530 70
2070 70 4600 70 3130 70
70 6670 70 3200
70 5700 70 1500 70 2530 70
60070 2130 70 3870 70600 2600
6140
1530
9530
7029
3070
2425
7038
9570
1530
7060
70
1600
3895
2495
7053
070
1120
7011
4070
6410
4150
2070
4570
7045
0070
1930
7024
0070
1680
7035
0070
2700
70
7060
0070
7990
7029
3070
OBS
OBS
PANPANTRYFR FRIDGE SPACEC COOKEREH EXTRACT HOODS SINKDW DISHWASHER SPACEB BATHWHB WASH HAND BASINSHW SHOWERWC TOILETFW FLOOR WASTEROBE WARDROBEWIRWALK IN ROBELINENLINEN CUPBOARDOHCUP OVER HEAD CUPBOARDWM WASHING MACHINED DRYERDP DOWNPIPEDPSP DOWNPIPE WITH SPREADERSD SLIDING DOORSTACK STACKER DOORBIBIFOLDCS CAVITY SLIDING DOORSW SLIDING WINDOWFG FIXED GLASSDH DOUBLE HUNG WINDOWAW AWINING WINDOWCW CASEMENT WINDOWLVRLOUVRE WINDOWOBS OBSCURE GLASSTBC TO BE CONFIRMEDCOS CHECK ON SITEOMP OUTER MOST PROJECTIONTIM TIMBERFESFIXED EXTERNAL SCREENSLS LANDSCAPING
LEGEND
1. LIFT OFF DOOR TO BE FITTED TO WC.2. SMOKE ALARMS TO COMPLY WITH BCA
CLASS 1 & 10 PART 3.7.2 AND WITH AS3786.
3. TERMITE TREATMENT TO AS 3660.1,1-2000 & BCA VOL 2 PART 3.1.3 GRADEDSTONE TO EXTERNAL WALL CAVITY ANDCOLLARS (IN ACCORDANCE WITH AS) TOALL SLAB PENETRATIONS. TERMITESTICKER TO BE IN METERBOX IN VISIBLEPOSITION.
4. ALL HANDRAILS TO 1000mm HIGH AND TOCOMPLY WITH THE REQUIREMENTS OFBCA AND ANY LOCAL REGULATIONS.HANDRAILS BOTH SIDES OF ALL STAIRS.
5. SEE SPECIFICATION FOR BEDROOMWINDOW SAFETY REQUIRMENTS.
6. ALL DIMENSIONS TO BE CHECKED ONSITE AND ANY DISCREPANCIESREPORTED TO THE DESIGNER.
7. THESE DRAWING SHALL BE READ INCONJUNCTION WITH THE ENGINEERSDOCUMENTS AND TOWN PLANNINGCONDITIONS OF PERMIT.
8. ALL WORK AND MATERIALS SHALL BE INACCORDANCE WITH THE DRAWINGS,SPECIFICATIONS AND CURRENTRELEVANT AUSTRALIAN STANDARD, THEBUILDING CODE OF AUSTRALIA ANDOTHER STATUTORY REQUIREMENTS.
9. ALL DIMENSIONS ARE IN MILLIMETERSUNLESS NOTED OTHERWISE.
10. ALL DOORS ARE 870mm WIDE TO ALLOW850mm OPENING AND ALL THRESHOLDSARE 0mm STEP TO COMPLY WITHAS4299-1995 ADAPTABLE HOUSING CODE.
GENERAL NOTES
DP
DP
DPDP
DP
DP
20°
20°
20°
20°
20°
20°
RIDG
E
RIDG
E
VALLEY
HIPHIP
HIP
HIP
HIP
HIP
WHIRLYBIRD
SOLAR PANELS TBC
COLOURBOND CUSTOMORB ROOF SHEETING,FIXED TO MANUFACTURERS SPECIFICATIONSON PREFABRICATED TIMBER ROOF TRUSSES ,INSULATION AS PER STAR ENERGY RATING
COLOURBOND ROOFING,GUTTERS AND FASCIA
485
450
415
450
415
450
485
0405 097 553 www.alldd.com.auQBSA Lic. 1084590
ArchitecturalBuilding DesignResidentialCommercialRenovations
all design
and
draf
ting
Scale
Date
Project number
THIS DRAWING IS THECOPYRIGHT AND PROPOERTY OFALL DESIGN AND DRAFTING. IT ISNOT TO BE COPIED, RETAINED ORUSED FOR ANOTHER PURPOSE.
CClient:
Project:
Address:
Property Details:
CALEZAC PTY LTD
MULTI HOUSINGDEVELOPMENT
LOT 10 & 11KAURI STREET COOROYQLD 4563
PROPOSED LOT 10RECONFIGURATION OF LOT 22 ON C56016 Drawing no.
Issue Details:
06-11-2015
11489
Development Application10 11/04/2015
Amendments11 12/11/2015
Pre BA12 06/11/2015
QBCCPre BA13 15/12/2015
Pre BA14 16/12/2015
Pre BA15 27/01/2016
UNIT TYPE C FLOOR & ROOFPLANS
BA12
1 : 100
UNIT TYPE CFLOOR PLAN1
1:100 (A3)
1 : 100
UNIT TYPE CROOF PLAN2
UNIT TYPE CUNIT C INTERNAL FLOOR AREA 134 m²UNIT C PORCH 7 m²UNIT C SERVICE COURT 1 m²UNIT C DECK 13 m²TOATL GROSS FLOOR AREA 155 m²
2700
OPE
NING
S
2100
COLOURBOND ROOFING, GUTTERS AND FASCIAS
20.0
°
COLOURBOND PANEL LIFT GARAGE DOORALUMINIUM AND OBSGLASS BALUSTRADE1000mm H
SOLAR PANELS TBC
WCT 1WCT 3
2700
OPE
NING
S
2100
COLOURBOND ROOFING, GUTTERS AND FASCIAS
20.0
°
ALUMINIUM AND OBSGLASS BALUSTRADE1000mm H
TYPICAL ELEVATIONSGROUND LEVEL VARIES
PROVIDE BALUSTRADE 1000mm HIN ALL LOCATIONS 1000mmABOVE GL
WCT 2WCT 2
WCT 3
2700
OPE
NING
S
2100
COLOURBOND ROOFING, GUTTERS AND FASCIAS
20.0
°
TYPICAL ELEVATIONSGROUND LEVEL VARIES
PROVIDE BALUSTRADE 1000mm HIN ALL LOCATIONS 1000mmABOVE GL
NOTE: SKIRT SCREEN MAY BE REQUIREDSHOULD GL BE MORE THAN 3m FROMUNDERSIDE OF FLOOR MEMBERS
WCT 2
PROVIDE MIN. 12.6m3WEATHERPROOFSTORAGE AREA INUNDERCROFT
2700
875 O
PENI
NGS
2100
COLOURBOND ROOFING, GUTTERS AND FASCIAS
20.0
°
TYPICAL ELEVATIONSGROUND LEVEL VARIES
SLIDING WINDOW OBS GLASS
WCT 1
WCT 2
WALL CLADDING LEGEND
WCT 1 COLOURBOND CUSTOM ORB VERTICAL CLADDING
WCT2 TBCCEMINTEL EDGE (DIRECT FIX, NOT PREFINISHED)150mm VERTICAL
WCT3 TBCCEMINTEL SMOOTH (TOP HAT FIXING, PREFINSHED) ORCEMINTEL ASPECT (DIRECT FIX, NOT PREFINISHED)12mm X 300mm HORIZONTAL
0405 097 553 www.alldd.com.auQBSA Lic. 1084590
ArchitecturalBuilding DesignResidentialCommercialRenovations
all design
and
draf
ting
Scale
Date
Project number
THIS DRAWING IS THECOPYRIGHT AND PROPOERTY OFALL DESIGN AND DRAFTING. IT ISNOT TO BE COPIED, RETAINED ORUSED FOR ANOTHER PURPOSE.
CClient:
Project:
Address:
Property Details:
CALEZAC PTY LTD
MULTI HOUSINGDEVELOPMENT
LOT 10 & 11KAURI STREET COOROYQLD 4563
PROPOSED LOT 10RECONFIGURATION OF LOT 22 ON C56016 Drawing no.
Issue Details:
06-11-2015
11489
Development Application10 11/04/2015
Amendments11 12/11/2015
Pre BA12 06/11/2015
QBCCPre BA13 15/12/2015
Pre BA14 16/12/2015
Pre BA15 27/01/2016
UNIT TYPE C ELEVATIONS
BA13
1 : 100
TYPE CFRONT1
1 : 100
TYPE C LEFT2
1 : 100
TYPE CREAR3
1 : 100
TYPE CRIGHT4
S
METERBOARD
SMOKE DETECTOR
WALL LIGHT
CEILING LIGHT
CEILING FAN
LCEILING FAN WITH LIGHT
SINGLE POWER POINT GPO
DOUBLE POWER POINT GPO
SOLAR SWITCH BOARD
HOT WATER SYSTEM
AC AIRCONDITIONING UNIT
EXHAUST FANE
EXHAUST FAN HEATER LIGHTFHL
PHONE & OR DATA
TV
P
TV POINT
LEGEND
NOTES:1. 80% OF FLOOR AREA TO FITTED WITH ENERGYEFFICIENT LIGHTING TO COMPLY WITH CURRENTREQUIRED STAR RATING.2. ALL EXTRACT FANS TO BE DUCTED ANDDISCHARGED TO OPEN AIR.3. ALL FITTINGS SHOWN ARE GENERIC ONLY,FITTINGS TO BE SELECTED BY OWNER.4. ALL ELECTRICAL WORK TO BE DONE BYAPPROPRIATELY QUALIFIED PERSONS TO RELEVANTCODES AND STANDARDS.5. DIMMER LOCATIONS SHOWN ON PLANS MAY NOTBE SUITABLE FOR FITTINGS SELECTED.6. GPO TYPICALLY 300mm ABOVE FFL7. SWITCHES TYPICALLY 1100mm ABOVE FFL8. SMOKE ALARMS TO COMPLY WITH NCC F3.7.2DESIGN OF SMOKE ALARMS MUST COMPLY WITH AS3786. A CERTIFICATE OF INSTALLATION FORM ALICENCE ELECTRICAL CONTRACTOR IS REQUIRED ATFINAL INSPECTION.
WIRING TO LIGHT SWITCH
DISHWASHER
COOKER
DW
C
DIMMER SWITCHD
LL
S
S
FHL
FHL
E
DW
C
BELOW FLOOR
TV TV
P
AC
0405 097 553 www.alldd.com.auQBSA Lic. 1084590
ArchitecturalBuilding DesignResidentialCommercialRenovations
all design
and
draf
ting
Scale
Date
Project number
THIS DRAWING IS THECOPYRIGHT AND PROPOERTY OFALL DESIGN AND DRAFTING. IT ISNOT TO BE COPIED, RETAINED ORUSED FOR ANOTHER PURPOSE.
CClient:
Project:
Address:
Property Details:
CALEZAC PTY LTD
MULTI HOUSINGDEVELOPMENT
LOT 10 & 11KAURI STREET COOROYQLD 4563
PROPOSED LOT 10RECONFIGURATION OF LOT 22 ON C56016 Drawing no.
Issue Details:
06-11-2015
11489
Development Application10 11/04/2015
Amendments11 12/11/2015
Pre BA12 06/11/2015
QBCCPre BA13 15/12/2015
Pre BA14 16/12/2015
Pre BA15 27/01/2016
UNIT TYPE C ELECTRICAL PLAN
BA14
450
20.0
°
COLOURBOND CUSTOM ORBROOFING
TIMBER ROOF TRUSSES TOMANUFACTURERS SPEC.SELECTED ROOF BATTENSSARKING TURNED DOWN INTOGUTTER
COLOURBOND METAL GUTTER
COLOURBOND METAL FASCIA
FC SOFIT LINING
BULK INSULATION AND BUILDINGPAPER AS REQUIRED AS PERREQUIRED STAR RATINGTIMBER STUD
FRAMING
PLASTER BOARDINTERIOR WALL AND
CEILING LINING
CEILING INSULATIONAS REQUIRED FOR
STAR RATING1000
NOTE:THE HEIGHT OF FINISHED INTERNAL SLAB LEVELABOVE EXTERNAL FINISHED SURFACES SHALL BE ASFOLLOWS:A) 150mm ABOVE FINISHED GROUND LEVELB) 100mm ABOVE SANDY, WELL-DRAINED AREASC) 50mm ABOVE PAVED/CONCRETED AREAS THATSLOPE AWAY FROM THE BUILDING @ 1:50MIN.NOTE:EXTERNAL FINISHED SURFACE SURROUNDING THESLAB MUST BE DRAINED TO MOVE SURFACE WATERAWAY FROM THE BUILDING AND GRADED TO GIVE ASLOPE OF NOT LESS THAN 50mm OVER THE FIRST1000mm FROM THE BUILDING.
50
FINISHED GROUND LEVEL
REINFORCED CONCRETE FLOOR SLABAND FOOTINGS TO ENGINEERS SPEC. ONPOLYTHENE UNDERLAY ON COMPACTEDSAND BED, LAP AND TAPE ALL JOINTS ANDPENETRATIONS TERMITE TREATMENT TOAS 3660.1
TIMBER WALL FRAMINGTO ENGINEERS SPEC.10mm PLASTERBOARDINTERIOR WALL ANDCEILING LINING WITHSELECTED COVING NDSKIRTING
2700
OPE
NING
S
2100
450
450
GARAGE
20.0
°
Architectural SpecificationThe owner/builder, subcontractor shall verify all dimensions, levels, setbacks and specifications prior to commencing any works or ordering materials and shall beresponsible for ensuring that all building works conform to the Building Code of Australia, Australian Standards (current editions), building regulations, local bylawsand town planning requirements.BCA and Standards - GeneralAll works shall comply with the BCA 2012 and not be limited to the following Australian Standard:AS 1288-2006 - Glass in buildings selections and installationsAS 1562 - 1992 Design and installation of sheet roof and wall cladding. Part 1 MetalAS 1684.2 - 2010 - National Timber Framing CodeAS 1860 - 1998 - Installation of particleboard flooringAS 2047 - 1999 - Windows in buildings selection and installationsAS 2049 - 2002 - Roof TilesAS 2050 - 2002 Installation of roofing TilesAS 2870 - 2011 - Residential slabs and footing constructionAS 2904 - 1995 - Damp proof courses and flashingAS 3600 - 2009 - Concrete StructuresAs 3660.1 - 2000 - Protection of building against subterranean termites Part 1 new buildingsAS 3700 - 2011 - Masonry structuresAS 3740 - 2010 & BCA Part 3.8.1 Water proofing of wet areas in residential buildingsAS - 3786 - 1993 - Smoke AlarmsAS - 4256 - 1994/1996 Plastic roof and wall cladding materials.General1. Architectural plans shall be read in conjunction with any structural or civil engineering computations, drawings and soil reports.2. Footing to be founded at the minimum depths indicated in the soil report.3. Footings not to encroach title boundaries and easement lines.4. The builder shall take all steps necessary to ensure the stability of new and existing structures during all works.5. The builder shall ensure for the general water tightness of all new and existing works.GLAZINGGlazing shall comply with AS 1288 - 2006 & AS 2047 with safety glazing to be used in the following cases:1. All rooms within 500mm vertical of the floor2. Bathrooms within 1500 vertical from the bath base3. Laundry within 1200mm vertical form floor and/or within 300mm horizontal from all doors.4. Doorway within 300mm horizontal from all doors.5. Shower screens shall be grade A Safety Glass.OPENABLE BEDROOM WINDOWSRequirements for openable windows in Bedrooms in BCA D2.24 & 3.9.2.5 stipulate:1. Protection to bedroom windows where the sill is less than 1.7m above floor level and the floor below the window is more than 2m above the surface beneath; and2. A device to restrict the window opening: orA screen with secure fittings,- not permitting a 125mm sohere to pass through- Restrict a force of 250 N- Child resistant release mechanism if screen or device is able to be removed.STORMWATER & SERVICESStormwater shall comply with AS/NZ3500.3 - 20031. Stormwater shall be taken to legal point of discharge to the satisfaction of the relevant authority2. Sewer or septic system shall be in accordance with the relevant authorities requirementsCORROSIONFor buildings in areas less than 1km form breaking surf or less than 100m form salt water not subject to breaking surf or in heavy industrial areas wall ties shall beeither: Grade 316 or 316L stainless steel, or engineered polymer ties.WET AREAS1. All wet areas to comply with Part 3.8.1 BCA Vol 2 and AS 3740 - 2010. Wall finishes shall be water resistant to a height of 1800 above floor level to showerenclosures and 150mm above baths, basins, sinks and troughs if within 75mm of the wall.2. Timber floors including particleboard and plywood in areas adjacent to baths and spas and outside shower areas to be waterproofed as per Part 3.8.1 BCA Vol. 2and AS 40-2010.VENTILATION1. Mechanical ventilation to be installed in accordance with Part 3.8.5 of the BCA2. Provide clearance form underside of bearer to finished ground level of 150mm for floor with strip flooring of 200mm for floors with particleboard flooring OR 300MMWHERE IN TERMITE PRONE AREA.3. Sub floor vents to provide a rate 6000mm sq. clear ventilation per 1000mm run of external masonry wall.INSULATIONthermal insulation to be provided as follows for slab construction. (refer of energy rating report) r.f.i. to have flammability index not exceeding 5STAIRS AND BALUSTRADES1. Stairs, stairways and balustrades to comply with BCA 3.9.1 and 3.9.2Stair requirements: (other than spiral stairs)risers 190mm maximum, 115 minimumgoing 355 maximum 240mm minimumprivate stairs (and 250mm for public stairs), risers and treads to be constant in size throughout flight.2. Provide nonslip finish or suitable non skid strip near edge of nosing. Ensure maximum gap between risers not to exceed 125mm or use closed rises. Providecontinuous handrail 1000mm minimum.3. Height to balconies and decks which are 1000mm or more above ground level, 865mm minimum height handrail above stair nosing and landings.4. Maximum opening between balusters not exceed 125mm.5. Continuous handrail to be installed to one side of stair compliant with part 3.9.2.4 of the BCA 2012LIGHTING1. Artificial lighting to comply with AS/NZS 1680.0 - 20092. Artificial lighting to be installed in accordance with Part 3.12.5.5 of the BCA 2012.THRESHOLDSIf the threshold sill of the doorway is greater than 190mm above the finished surface of the ground to which the doorway opens, a landing shall be provided no lessthan the width of the door leaf, or 900mm wide x 900mm long, which ever is greater.SMOKE ALARMS1. Location of smoke alarm to be provided and installed in accordance with AS 3786 - 1993And Part 3.7.2 of the BCA 2012 and shall be hard wired with battery backup.MASONRY1. Masonry to comply with AS3700 - 2011 or AS4773.1 1-2010 & AS4773.2 - 20102. Provide wall ties to brickwork as per 36.3.3.2 BCA Generally wall ties to be 600mm ctrs in each direction for cavity masonry, for masonry veneer: 600x450 for 450stud walls and 600x600 for 600 stud walls and within 300mm of articulation joints.3. Provide wall ties to brickwork at maximum 5000mm ctrs in each directions and within 300mm of articulation joints 2200mmsq. clear ventilation per 1000mm run ofinternal dwarf walls.4. Spacing of wall ties to top and sides of opening to be halved.
2700
20.0
°
BEDROOM 1 LIVINGROOM KITCHEN
SELECTED SHEETFLOORING ONTIMBER FLOORFRAMING AND POLEFOUNDATION TOENGINEERS SPEC.
COLOURBOND CUSTOMORBSHEET METAL ROOFING, FIXEDTO MANUFACTURERS SPEC. ONPREFABRICATED TIMBER ROOFTRUSSES TO MANUFACTURERSSPEC. INSULATION AS PER STARRATING
RAINWATERTANK
450 450
2100
0405 097 553 www.alldd.com.auQBSA Lic. 1084590
ArchitecturalBuilding DesignResidentialCommercialRenovations
all design
and
draf
ting
Scale
Date
Project number
THIS DRAWING IS THECOPYRIGHT AND PROPOERTY OFALL DESIGN AND DRAFTING. IT ISNOT TO BE COPIED, RETAINED ORUSED FOR ANOTHER PURPOSE.
CClient:
Project:
Address:
Property Details:
CALEZAC PTY LTD
MULTI HOUSINGDEVELOPMENT
LOT 10 & 11KAURI STREET COOROYQLD 4563
PROPOSED LOT 10RECONFIGURATION OF LOT 22 ON C56016 Drawing no.
Issue Details:
06-11-2015
11489
Development Application10 11/04/2015
Amendments11 12/11/2015
Pre BA12 06/11/2015
QBCCPre BA13 15/12/2015
Pre BA14 16/12/2015
Pre BA15 27/01/2016
TYPICAL SECTIONS, DETAILSAND SPECIFICATION
BA15
1 : 20
DETAIL 13 1 : 20
DETAIL 24
1 : 100
SECTIONTHROUGHGARAGE
1
1 : 100
SECTIONTHROUGHHOUSE
2