001/ AR13/14 10/14 Engineering Project No SPPC Project NO EPPM Document NO Rev AR 13/14 P11.SC1401 R1314-LIS-PR-05-001 0 Date 10/27/2014 Page 1 of 4 List LINE LIST FOR ATBARA STATION 0 2/2/2015 Final Issue GHZ HAJ JI Rev Date Description Name Visa Name Visa Name SUDANESE PETROLEUM PIPELINES COMPANY SUDAN

AR1314 LINE LIST FOR ASSAUT STATION.xlsx

  • Upload
    abboud

  • View
    213

  • Download
    1

Embed Size (px)

Citation preview

PGProject : Upgrading the Capacity of 12 inch Pipeline Project

EngineeringProject NoSPPC Project NOEPPM Document NORevAR 13/14P11.SC1401R1314-LIS-PR-05-0010Date 10/27/14Page1of4List

LINE LIST FOR ATBARA STATION

SUDANESE PETROLEUM PIPELINES COMPANY SUDAN

02/2/15Final IssueGHZHAJJIRevDateDescriptionNameVisa NameVisa NameVisa Prepared byChecked byApproved by

&"Arial,Normal"&8 001/ AR13/14&"Arial,Normal"&8 10/14

HISNO. R1314-LIS-PR-05-001LINE LIST FOR ATBARA STATIONREV.0SHEET: 2/4List

SHEETSREVISIONSREVISIONSAB0SHEETSAB01*X352**X363X374X385396407418429431044114512461347144815491650175118521953205421552256235724582559266027612862296330643165326633673468Note : * front page ** this page REVISIONS REPORTREVISIONREASON FOR ISSUE0FINAL ISSUE

002/AR13/1410/14

ATBARA STATIONLINE LIST FOR ASSAUT STATIONNO. R1314-LIS-SF-02-002REV.0SHEET: 1/2LISTAREAN.DinchSERVICELINE No.PIPE SPECINSULATION DESIGNATIONFLUIDPHASEROUTINGNORMAL OPERATING COND.PROCES PROCESS DESIGN COND.
Auteur: Auteur:Selon ASMETESTING
Auteur: Auteur:Selon ASMESTEAM ORELEC,TRACEINSULATION
Auteur: Auteur:calorifugeageP.&.I.D NumberNOTESMEDIUMFROMTOTEMP.
Auteur: Auteur:intervalle de temprature ambiantePRESS.
Auteur: Auteur:[P min dans le rsau---------->1,4 x P de fct de pompe principaleTEMP.(*)PRESS.MEDPRESS.INSUL.INSUL.OCbargOCbargbargTHK.mmTYPE1504"FW1001A3CVWATERLIQUID150-P2000150-6"-FW-1004-A3C-V5-375,12 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 1/21504"FW1002A3CVWATERLIQUIDFILLING TRUCK150-P20055-375,12 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 1/21504"FW1003A3CVWATERLIQUID150-P2005150-6"-FW-1004-A3C-V5-375,12 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 1/21506"FW1004A3CVWATERLIQUIDIntel water header5-375,12 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 1/21506"FW1005A3CVWATERLIQUID150-6"-FW-1004-A3C-V150-T-20015-375,12 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 1/215012"FW1006A3CVWATERLIQUIDMain Pumps suction header 5-375,12 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 1/21504"FW1007A3CVWATERLIQUID150-12"-FW-1006-A3C-V150-6"-FW-1016-A3C-V5-375,12 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 1/21503"FW1008A3CVWATERLIQUID150-12"-FW-1006-A3C-V150-P-20015-375,12 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 1/21502" 1/2FW1009A3CVWATERLIQUID150-P-2001150-6"-FW-1016-A3C-V5-375,12 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 1/21503"FW1010A3CVWATERLIQUID150-12"-FW-1006-A3C-V150-P-20025-375,12 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 1/21502" 1/2FW1011A3CVWATERLIQUID150-P-2002150-6"-FW-1016-A3C-V5-375,12 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 1/215010"FW1012A3CVWATERLIQUID150-12"-FW-1006-A3C-V150-P-20035-375,12 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 1/21506"FW1013A3CVWATERLIQUID150-P-2003150-6"-FW-1016-A3C-V5-375,12 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 1/215010"FW1014A3CVWATERLIQUID150-12"-FW-1006-A3C-V150-P20045-375,12 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 1/21506"FW1015A3CVWATERLIQUID150-P-2004150-6"-FW-1016-A3C-V5-375,12 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 1/21506"FW1016A3CVWATERLIQUIDMain pumps discharge Header 5-375,12 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 1/21506"FW1017A3CVWATERLIQUID150-6"-FW-1016-A3C-V150-T-20015-375,12 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 1/21504"FW1018A3CVWATERLIQUID150-6"-FW-1016-A3C-V150-PSV-2035-375,12 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 1/21506"FW1019A3CVWATERLIQUID150-PSV-203150-6"-FW-1017-A3C-V5-375,12 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 1/21506"FW1020A3CVWATERLIQUID150-6"-FW-1016-A3C-VR1314-DWG-SF-02-002 2/25-375,12 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 1/21506"FW1021A3CVWATERLIQUID150-6"-FW-1016-A3C-VR1314-DWG-SF-02-002 2/25-375,12 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 1/21502"SW1001A3CVWATERLIQUID150-T-2001R1314-DWG-PR-02-001 2/25-375,12 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 1/2LINE LIST FOR ASSAUT STATIONNO. R1314-LIS-SF-02-002REV.0SHEET: 2/2LISTAREAN.DinchSERVICELINE No.PIPE SPECINSULATION DESIGNATIONFLUIDPHASEROUTINGNORMAL OPERATING COND.PROCES PROCESS DESIGN COND.TESTINGSTEAM ORELEC,TRACEINSULATIONP.&.I.D NumberNOTESMEDIUMFROMTOTEMP.PRESS.TEMP.(*)PRESS.MEDPRESS.INSUL.INSUL.OCbargOCbargbargTHK.mmTYPE1506"FW1020A3CVWATERLIQUIDR1314-DWG-SF-02-002 1/2150-6"-FW-1022-A3C-V5-375,2 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 2/21506"FW1021A3CVWATERLIQUIDR1314-DWG-SF-02-002 1/2150-6"-FW-1022-A3C-V5-375,2 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 2/21506"FW1022A3CVWATERLIQUIDR1314-DWG-SF-02-002 1/2150-6"-FW-1023-A3C-V5-375,2 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 2/21506"FW1023A3CVWATERLIQUID150-6"-FW-1022-A3C-V150-6"-FW-1025-A3C-V5-375,2 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 2/21503"FW1024A3CVWATERLIQUID150-6"-FW-1023-A3C-V150-FM-0025-375,2 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 2/21506"FW1025A3CVWATERLIQUID150-6"-FW-1023-A3C-V150-3"-FW-1026-A3C-V5-375,2 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 2/21503"FW1026A3CVWATERLIQUID150-6"-FW-1025-A3C-V150-FM-0035-375,2 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 2/21503"FW1027A3CVWATERLIQUID150-6"-FW-1025-A3C-V150-FM-0045-375,2 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 2/21506"FW1028A3CVWATERLIQUID150-6"-FW-1022-A3C-V150-4"-FW-1030-A3C-V5-375,2 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 2/21503"FW1029A3CVWATERLIQUID150-6"-FW-1028-A3C-V150-FM-0015-375,2 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 2/21504"FW1030A3CVWATERLIQUID150-6"-FW-1028-A3C-V150-FSK-0015-375,2 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 2/21502" 1/2FW1031A3CVWATERLIQUID150-6"-FW-1023-A3C-VFOAM/WATER HOSE REEL STATION5-375,2 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 2/21502" 1/2FW1032A3CVWATERLIQUID150-6"-FW-1025-A3C-VFOAM/WATER HOSE REEL STATION5-375,2 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 2/21502" 1/2FW1033A3CVWATERLIQUID150-6"-FW-1022-A3C-VFOAM/WATER HOSE REEL STATION5-375,2 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 2/21502" 1/2FW1034A3CVWATERLIQUID150-6"-FW-1022-A3C-VFOAM/WATER HOSE REEL STATION5-375,2 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 2/21502" 1/2FW1035A3CVWATERLIQUID150-6"-FW-1022-A3C-VFOAM/WATER HOSE REEL STATION5-375,2 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 2/21503"FD1031A3CVFOAMLIQUID150-FSK-001NEW PUMPING STATION5-375,2 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 2/21502" 1/2FD1032A3CVFOAMLIQUID150-FSK-002FOAM DISCHARGE OUTLET5-375,2 to 11,27018.6WATER27.9NONANAR1314-DWG-SF-02-002 sheet 2/2

ABBREVIATIONS:FW :Fire waterSW:Service waterFD :Foam waterFSK :Foam skid(*) :Due to solar radiationFM :Foam monitorSF:SafetyV:PaintedPSV:Pressure valve safetyNA:Not applicable