TECHNICAL MANUAL & PRODUCT CATALOGUE
ASTM uPVC SOLVENT
WELD PLUMBING SYSTEM
No ElectricalTools Required
CorrosionResistant
Safe ForDrinking Water
CostEffective
Easy ColdWelding Process
UVResistance
MCGM
APPROVEDAPPROVED
1. Certification & Approvals 01
2. Introduction 02
3. Key Properties 03
4. Difference Between uPVC & PVC 04
5. Standards & Specifications 05
6. Pressure Rating 06
7. Basic Socket Dimensions 08
8. uPVC Schedule 40 & Schedule 80 Pressure Fittings 09
9. uPVC Solvent Cement 15
10. Installation Procedures 16
11. Joint Curing / Support Spacing For uPVC Pipe 17
12. Carrying Capacity & Friction Loss For Schedule 40 Pipe 18
13. Carrying Capacity & Friction Loss For Schedule 80 Pipe 19
14. Testing Pressure System 20
15. Underground Installation 21
16. Handling & Storage 22
17. Frequently Asked Questions 22
18.
I N D E X
1
CERTIFICATES & APPROVALS
Factory - Santej, Ahmedabad
2
ASTRAL have been relentless in its commitment to
quality and service. Through the years, ASTRAL have broadened
and enhanced its product line to serve better to the customers.
ASTRAL was first to introduce FlowGuard CPVC pipes and fittings
in Indian market and now repeating its tradition, ASTRAL is very
proud to introduce
under the brand name .
are and
hence non toxic, easy to install and are made for life time trouble
free service. ASTRAL Aquarius pipes and fittings are available in
range of 15 mm (½”) to 300 mm (12”) with two different class
SCH 40 and SCH 80.As the full line leading manufacturer of CPVC pipes and
fittings for residential and industrial applications and now with
ASTM uPVC pressure pipes and fittings, ASTRAL can be your one
stop source for all the plastic piping system you require for
lifetime plumbing solution.
Lead Free ASTM uPVC Solvent Weld
Plumbing System ‘ASTRAL Aquarius’
Lead FreeASTRAL Aquarius ASTM uPVC pipes and fittings
PVC is one of the specified thermoplastic for piping
system components, including valves, fittings, flanges and many
speciality products. PVC has excellent chemical and corrosion
resistance to a broad range of fluids. ASTRAL uPVC materials conform to ASTM Cell
Classification 12454-B of ASTM D1784 (formally designated as
Type I, Grade I). The maximum recommended service
temperature of PVC products is 60°C (140°F)
PVC - POLYVINYL CHLORIDE
PVC makes a major contribution to the quality, safety
and cost-effectiveness of construction materials, as well as helping
to reduce the environmental impact of completed projects.
PVC is the most widely used polymer in building and
construction applications and over 50 percent of Western
Europe’s annual PVC production is used in this sector.
PVC has a versatility that helps to meet modern and
future design needs.
WHAT MAKES PVC IMPORTANT?
INTRODUCTION
ASTRAL Aquarius uPVC pipes being lead free are non-
toxic and hence favoured for use in applications such as potable
water pipes. ASTRAL Aquarius uPVC Plumbing system utilizes NSF
(National Sanitation Foundation) approved one -step solvent
cement, specifically formulated for the use. Joining is
accomplished quickly and efficiently utilizing inexpensive tools
thereby greatly reducing labor and installation costs.
BENEFITS OF ASTRAL AQUARIUS SYSTEM OVER OTHER uPVC SYSTEMS
ThreadeduPVC Pipe
Solvent welduPVC Pipe
ASTRAL Aquarius uPVC solvent joint plumbing
system makes its pressure bearing capacity twice than that of the
threaded pipe.
ASTRAL Aquarius uPVC pipes & fittings exhibit the well-
known physical characteristics and other benefits of conventional
uPVC piping such as good chemical and corrosion resistance, low
thermal conductivity, high strength-to-weight ratio, good impact
resistance and ease of installation.
Corporate Office - AhmedabadCorporate Office - Ahmedabad
3
The key properties of ASTRAL Aquarius high pressure Lead Free Plumbing System are significant with following features:
ASTRAL Aquarius Lead Free Plumbing System is tough, durable with high tensile and impact strength. The system is light in weight and can be transported easily from one place to another.
ASTRAL Aquarius Lead Free pipes can be cut, shaped, welded and jointed easily.
ASTRAL Aquarius Lead Free Plumbing System is inherently difficult to ignite and stops burning once the source of heat is removed. Compared to its common plastic alternatives PVC performs better in terms of lower combustibility, flammability, flame propagation and heat release. Newly developed advantages in terms of lower acid emissions, smoke generation and enhanced fire resistance.
ASTRAL Aquarius Lead Free Plumbing System is durable and free from weaknesses caused by rusting, weathering and chemical action and hence last for life time.
ASTRAL Aquarius Lead Free Plumbing System can be used in sunlight exposed conditions. However, ASTRAL recommends a standard grade of exterior latex paint (water base) which will protect the system adequately.
Jointing can be done speedily with special IPS solvent cement supplied by the company which ensures 100% leak proof joints.
ASTRAL Aquarius pipes are non-toxic and lead free which makes them a safe material for potable water. It is also the world's most researched and thoroughly tested material for PVC which meets all international standards for safety and health for both the products and applications.
Smooth inner surface ensures high flow rate and low friction losses. The system is leach and scale free.
PVC does not conduct electricity. ASTRAL Aquarius pipes are non conductor of electricity so it make the plumbing system safe when working with electrical tools or equipments.
uPVC is generally inert to most mineral acids, bases, salts and paraffinic hydrocarbon solutions. For more information on uPVC chemical resistance refer to Chemical Resistance of Rigid Vinyls Based.
ASTRAL Aquarius Lead Free Plumbing System available from ½" (15 mm) to 12" (300 mm) with wide range of fittings, transition fittings, valves and specially designed brass inserted fittings to suit any design criteria.
STRONG AND LIGHT WEIGHT
EASY TO INSTALL
FIRE RESISTANT
DURABLE
UV STABILIZED
SIMPLE AND LEAK PROOF JOINTS
SAFE MATERIAL FOR DRINKING WATER
MAXIMUM FLOW RATE
GOOD INSULATOR
CHEMICAL RESISTANCE
WIDE RANGE
KEY PROPERTIES
4
FIELDS OF
APPLICATIONS
There has been a lot of confusion in the thermoplastics industry regarding the use of the terms uPVC
and PVC when specifying thermoplastic piping products. For many years, certain regions of the world have
preferred using the term uPVC when specifying unplasticized Polyvinyl Chioride piping products while other
regions of the world, The United State of America for instance, prefer the acronmy PVC (less the U) when
specifying the same unplasticized PVC piping products. Essentially, both references indicate that the type of
PVC required be unplasticized, rigid PVC.
The most important aspect of specifying PVC piping products is not the abbreviation but the cell
classification of the thermoplastic material. For rigid, unplasticized Type I Grade 1 PVC material with a
hydrostatic design stress of 2000psi the cell classification is 12454. These numbers indicate the minimum
physical properties that a rigid, unplasticized thermoplastic compound must meet per ASTM D1784 to be
used in the manufacture of pressure piping components.
In summary, whether a thermoplastic vinyl piping, product is specified as uPVC is not important, it is
the cell classification, and materials’ physical properties that is most important.
THE DIFFERENCE BETWEEN uPVC & PVC
5
DESCRIPTIVE CODES
IMPORTANT FOR INSTALLERS & USERS :
ASTM D 1784 - Rigid Poly Vinyl Chloride (PVC) Compounds.
ASTM D 1785 - Poly Vinyl Chloride (PVC) Plastic Pipes, SCH 40 & SCH 80.
ASTM D 2466 - Socket type Poly Vinyl Chloride (PVC) Plastic Pipe Fittings, SCH 40.
ASTM D 2467 - Socket type Poly Vinyl Chloride (PVC) Plastic Pipe Fittings, SCH 80.
ASTM D 2564 - Solvent Cements for Plastic Pipes & Fittings
ASTM F 1498 - Taper Pipe threads 60° for Thermoplastics Pipe & Fittings
ASTM D 2774 - Underground Installation of Thermoplastic Pipes.
ISO 7/1 - Pipe threads where pressure joints are made on threads -
Part 1 : Designation, Dimension & Tolerances.
ASTM - American Society for Testing of Materials. ANSI - American National Standards Institute
BSP - British Standard Pipe IPS - Iron Pipe Size (ASTM)
NPT - National Pipe Threads (ANSI) FIPT - Female Iron Pipe Threads
MIPT - Male Iron Pipe Threads SOCKET - Solvent Weld Socket
SPIGOT - Spigot End (IPS) FBSP - Female BSP Threads
MBSP - Male BSP Threads NSF - National Sanitation Foundation
PVC - Poly Vinyl Chloride EPDM - Ethylene Propylene Rubber
STANDARDS & SPECIFICATIONS
ASTRAL recommends that all uPVC Plastic piping systems
be designed and constructed to avoid excessive WATER HAMMER.
Water hammer can cause damage and failure to pipe, valves and
fittings within the piping system.
WATER HAMMER :
Use a quality grade thread sealant. Do not use substances
that could cause stress cracking to plastic. Major attention must
be given while making plastic thread joints. 1 to 2 turns beyond
FINGER TIGHT is generally all that is required to make a sound
plastic connection. Unnecessary OVER TIGHTENING will cause
DAMAGE TO BOTH PIPES & FITTINGS. Also give proper attention
while selecting the threaded fittings, as ASTRAL manufacture
some fittings with NPT threads & some fittings with BSP threads to
give more versatility to customer NPT threads are not compatible
with BSP threads.
THREADED CONNECTIONS :
Some Lubricants, including vegetable oils are known to
cause stress cracking in thermoplastics materials. A mild soap or
commercially available pipe gasket lubricants suitable for uPVC is
recommended where lubrication is required for installation or
maintenance service (especially with Flange joints). Choice of
lubricant is at the discretion of the installer.
SEAL & GASKET LUBRICANTS :
FLOW VELOCITIES :System should not be operated or flushed out at flow
velocities greater than 5 feet per second.
6
TEMPERATURE PRESSURE DE-RATING FACTORThe operating pressure of uPVC pipe will be reduced as the operating temperature increases above 23°C (73° F). To calculate this reduction, multiply the operating pressure with the correction factors shown below at a operating temperature of system :
Operating Temp. °C(F) 23°(73) 27°(80) 32°(90) 38°(100) 43°(110) 49°(120) 54°(130) 60°(140)
uPVC 100% 90% 75% 62% 50% 40% 30% 22%
NOTE : (1) Valves, Unions and Specialty Products have different elevated temperature ratings than pipes.
(2) Threaded valves should not be used at temperature above 110°F (43° C) for PVC
(3) Flanged joints have a base pressure rating of 150 PSI at 23° C
PRESSURE RATING @23°C uPVC SCHEDULE 40
PRESSURE RATING @23°C uPVC SCHEDULE 80
P 40-012 ½ 15 0.840 21.34 0.109 2.77 600 42.19P 40-034 ¾ 20 1.050 26.67 0.113 2.87 480 33.75P 40-001 1 25 1.315 33.40 0.133 3.38 450 31.64P 40-114 1¼ 32 1.660 42.16 0.140 3.56 370 26.01P 40-112 1½ 40 1.900 48.26 0.145 3.68 330 23.20P 40-002 2 50 2.375 60.32 0.154 3.91 280 19.69P 40-212 2½ 65 2.875 73.02 0.203 5.16 300 21.09P 40-003 3 80 3.500 88.90 0.216 5.49 260 18.28P 40-004 4 100 4.500 114.30 0.237 6.02 220 15.47P 40-006 6 150 6.625 168.28 0.280 7.11 180 12.66P 40-008 8 200 8.625 219.08 0.322 8.18 160 11.25P 40-100 10 250 10.750 273.05 0.365 9.27 140 9.84P 40-120 12 300 12.750 323.85 0.406 10.31 130 9.14
Mpa = Mega Pascal 1 MPa = 10 kg / cm² 1 kg / cm² = 14.223343 PSI.
Part Nom Avg. OD Avg. OD Min Wall Min Wall Max. Work Max. WorkNo. Size Thick Thick Pre. at 23°C Pre. at 23°C
(in.) (mm) (in.) (mm) (in.) (mm) PSI (kg/cm²)
P 80-012 ½ 15 0.840 21.34 0.147 3.73 850 59.76P 80-034 ¾ 20 1.050 26.67 0.154 3.91 690 48.51P 80-001 1 25 1.315 33.40 0.179 4.55 630 44.29P 80-114 1¼ 32 1.660 42.16 0.191 4.85 520 36.56P 80-112 1½ 40 1.900 48.26 0.200 5.08 470 33.04P 80-002 2 50 2.375 60.32 0.218 5.54 400 28.12P 80-212 2½ 65 2.875 73.02 0.276 7.01 420 29.53P 80-003 3 80 3.500 88.90 0.300 7.62 370 26.01P 80-004 4 100 4.500 114.30 0.337 8.56 320 22.50P 80-006 6 150 6.625 168.28 0.432 10.97 280 19.69P 80-008 8 200 8.625 219.08 0.500 12.70 250 17.57P 80-100 10 250 10.750 273.05 0.593 15.06 230 16.17P 80-120 12 300 12.750 323.85 0.687 17.45 230 16.17
Mpa = Mega Pascal 1 MPa = 10 kg / cm² 1 kg / cm² = 14.223343 PSI.
Part Nom Avg. OD Avg. OD Min Wall Min Wall Max. Work Max. WorkNo. Size Thick Thick Pre. at 23°C Pre. at 23°C
(in.) (mm) (in.) (mm) (in.) (mm) PSI (kg/cm²)
PRESSURE PIPES AND FITTINGSuPVC SCHEDULE 40 & SCHEDULE 80
AS PER ASTM D-1785
7
PVC SCHEDULE 40 AND SCHEDULE 80 FITTINGSSUGGESTED MAXIMUM INTERNAL WORKING PRESSURE @ 73°F (23°C)
The following information is provided as a guide only. Actual allowable working pressure may very widely according to
field conditions. Additionally, pressure de-rating at elevated temperatures must be taken into account. Certain fitting
configurations may have other assigned pressure limitations (i.e., Wyes, Unions, Flanges, Valves etc). Contact Astral
Technical Services for additional information.
Notes:
1 - Water pressure Ratings At 73°F (23°C) for Schedule 40 and Schedule 80 Plastic Pipe, ASTM D 1785 for PVC.
2 - Threading of Schedule 40 plastic pipe is not permitted. Recommended pressures apply to molded fittings only.
Nominal Size
42.19 25.31 21.09 59.76 35.85 29.88
¾ 33.75 20.24 16.87 48.51 29.10 24.25
1 31.64 18.98 15.81 44.29 26.57 22.14
1¼ 26.01 15.60 13.00 36.56 21.93 18.27
1½ 23.20 13.92 11.60 33.04 19.82 16.52
2 19.69 11.81 9.84 28.12 16.87 14.06
2½ 21.09 12.65 10.54 29.53 17.71 14.76
3 18.28 10.96 9.13 26.01 15.60 13.00
4 15.47 9.28 7.73 22.50 13.49 11.24
6 12.66 7.59 6.32 19.69 11.81 9.84
8 11.25 6.74 5.62 17.57 10.54 8.78
10 9.84 5.90 4.92 16.17 9.70 8.08
12 9.14 5.48 4.56 16.17 9.70 8.08
½
2Schedule 80 kg / cm
Solvent Cemented JointStandardThreaded
Joint(in.)
1Pipe1Pipe
StandardThreaded
3JointSolvent Cemented Joint
2Schedule 40 kg / cm
Not For Use With Compressed Air or Gas
8
AMERICAN NATIONAL STANDARD TAPER PIPE THREADS (NPT) ANSI STANDARD B1.20.1
ASTM STANDARD F 1498
Nominal Size
¾ 20 14 0.5457 0.07143
1 25 11½ 0.6828 0.08696
1¼ 32 11½ 0.7068 0.08696
1½ 40 11½ 0.7235 0.08696
2 50 11½ 0.7565 0.08696
2½ 65 8 1.1375 0.12500
3 80 8 1.2000 0.12500
4 100 8 1.3000 0.12500
½ 15 14 0.5337 0.07143
ThreadsPer in.
EffectiveThreadLength
L
Pitch ofThread
P(in.) (mm)
BSP ISO 7/1PARELLEL THREADS
Nominal Size
15 0.848 0.836 ±0.004 0.688 0.875
¾ 20 1.058 1.046 ±0.004 0.719 1.000
1 25 1.325 1.310 ±0.005 0.875 1.125
1¼ 32 1.670 1.655 ±0.005 0.938 1.250
1½ 40 1.912 1.894 ±0.006 1.094 1.375
2 50 2.387 2.369 ±0.006 1.156 1.500
2½ 65 2.889 2.868 ±0.007 1.750 1.750
3 80 3.516 3.492 ±0.008 1.875 1.875
4 100 4.518 4.491 ±0.009 2.000 2.250
6 150 6.647 6.614 ±0.011 3.000 3.000
8 200 8.655 8.610 ±0.015 4.000 4.000
10 250 10.780 10.735 ±0.015 5.000 5.000
12 300 12.780 12.735 ±0.015 6.000 6.000
½
EntranceA
Tolerance
Socket Length Minimum C (in.)Diameter (in.)Bottom
BSCH 40 SCH 80(in.) (mm)
BASIC SOCKET DIMENSIONSSCHEDULE 40 AS PER ASTM D-2466, SCHEDULE 80 AS PER ASTM D-2467
9
TEE - Soc
½ 15 M 401-005 50/ 550¾ 20 M 401-007 25/ 3001 25 M 401-010 25/ 1501¼ 32 M 401-012 10/ 1001½ 40 M 401-015 10 / 702 50 M 401-020 5/ 402½ 65 M 401-025 1 / 273 80 M 401-030 1 / 184 100 M 401-040 1 / 106 150 M 401-060 1 / 28 200
M 801-005 50 / 200M 801-007 25 / 125M 801-010 25 / 70M 801-012 10 / 40M 801-015 10 / 30M 801-020 5 / 15M 801-025 1 / 12M 801-030 1 / 7M 801-040 1 / 4M 801-060 1 / 2M 801-080 1 / 1
Size Size Part No. Std Pkg Part No. Std Pkg(In.) (mm) Bag/Case Bag/Case
SCHEDULE 40 SCHEDULE 80
Size Size Part No. Std Pkg (In.) (mm) Bag/Case
SCHEDULE 40
½ 15 M 402-005 50/ 250¾ 20 M 402-007 25/ 1251 25 M 402-010 25 / 751¼ 32 M 402-012 10/ 401½ 40 M 402-015 -- / 302 50 M 402-020 -- / 20
TEE - Soc x Fipt
Size Size Part No. Std Pkg Part No. Std Pkg(In.) (mm) Bag/Case Bag/Case
SCHEDULE 40 SCHEDULE 80
¾ x ½ 20 x 15 M 401-101 25 / 3001 x ½ 25 x 15 M 401-130 25/ 2001 x ¾ 25 x 20 M 401-131 25/ 1501¼ x ½ 32 x 15 M 401-166 10/ 1001¼ x ¾ 32 x 20 M 401-167 10/ 1001¼ x 1 32 x 25 M 401-168 10/ 1001½ x ½ 40 x 15 M 401-209 10 / 801½ x ¾ 40 x 20 M 401-210 10/ 401½ x 1 40 x 25 M 401-211 10/ 701½ x 1¼ 40 x 32 M 401-212 10/ 702 x ½ 50 x 15 M 401-247 5/ 352 x ¾ 50 x 20 M 401-248 5 / 352 x 1 50 x 25 M 401-249 5 / 352 x 1¼ 50 x 32 M 401-250 5 / 502 x 1½ 50 x 40 M 401-251 5 / 504 x 2 100 x 50 * 401-420 5 / --4 x 3 100 x 80 * 401-422 5 / --6 x 4 150 x 100 * 401-532 1 / –
M 801-101 25 / 150M 801-130 25 / 100M 801-131 25 / 100
M 801-209 10/ 50
M 801-211 10/ 40
M 801-247 5/ 30
M 801-249 5/ 20
M801-251 5/ 20
REDUCING TEE - Soc
* Trading Items
uPVC PRESSURE FITTINGSSCHEDULE 40 AS PER ASTM D-2466SCHEDULE 80 AS PER ASTM D-2467
10
BRASS 90°ELBOW - Soc x Fipt
Size Size Part No. Std Pkg(In.) (mm) Bag/Case
SCHEDULE 80
½ x ½ 15 x 15¾ x ½ 20 x 15¾ x ¾ 20 x 201 x ½ 25 x 15
M 806-005B 25 / 100M 806-101B 25 / 100M 806-007B 25 / 75M 806-130B 25 / 50
BRASS TEE-Soc x Fipt
Size Size Part No. Std Pkg(In.) (mm) Bag/Case
SCHEDULE 80
½ x ½ 15 x 15¾ x ½ 20 x 15¾ x¾ 20 x 201 x ½ 25 x 151 x ¾ 25 x 20
1¼ x ½ 32 x 15
M 801-005B 25 / 100M 801-101B 25/ 50M 801-007B -- / 50M 801-130B 25/ 25M 801-131B 25 / 25M 801-166B -- / 20
Size Size Part No. Std Pkg Part No. Std Pkg(In.) (mm) Bag/Case Bag/Case
SCHEDULE 40 SCHEDULE 80
½ 15 M 406-005 100 / 800¾ 20 M 406-007 50 / 4001 25 M 406-010 25 / 2501¼ 32 M 406-012 10 / 1501½ 40 M 406-015 10 / 1002 50 M 406-020 5 / 602½ 65 M 406-025 1 / 353 80 M 406-030 1 / 254 100 M 406-040 1 / 126 150 M 406-060 1- / 38 200
M 806-005 50 / 300M 806-007 50 / 200M 806-010 25 / 125M 806-012 10 / 60M 806-015 10 / 50M 806-020 5 / 25M 806-025 5 / 15M 806-030 1 / 10M 806-040 1 / 5M 806-060 1 / 3M 806-080 1 / 1
90° ELBOW - Soc
Size Size Part No. Std Pkg (In.) (mm) Bag/Case
SCHEDULE 40
½ 15 M 407-005 100 / 300¾ 20 M 407-007 50 / 2001 25 M 407-010 25 / 1001¼ 32 M 407-012 10 / 501½ 40 M 407-015 10 / 402 50 M 407-020 5 / 25
90° ELBOW -Soc x Fipt
Downtake line Application
uPVC PRESSURE FITTINGSSCHEDULE 40 AS PER ASTM D-2466SCHEDULE 80 AS PER ASTM D-2467
11
45° ELBOW -Soc
Size Size Part No. Std Pkg Part No. Std Pkg(In.) (mm) Bag/Case Bag/Case
SCHEDULE 40 SCHEDULE 80
½ 15 M 417-005 100 / 500¾ 20 M 417-007 50 / 2501 25 M 417-010 25 / 3001¼ 32 M 417-012 10 / 801½ 40 M 417-015 10 / 602 50 M 417-020 10 / 302½ 65 * 417-025 5 / --3 80 * 417-030 5 / --4 100 * 417-040 5 / –
M 817-005 100 / 400M 817-007 50 / 200M 817-010 25 / 150
M 817-040 1/6
COUPLING Soc
Size Size Part No. Std Pkg Part No. Std Pkg(In.) (mm) Bag/Case Bag/Case
SCHEDULE 40 SCHEDULE 80
½ 15 M 429-005 100/ 1200¾ 20 M 429-007 50 / 3001 25 M 429-010 25/ 3001¼ 32 M 429-012 10 / 2001½ 40 M 429-015 10 / 1502 50 M 429-020 10/ 1002½ 65 M 429-025 5 / 503 80 M 429-030 5 / 354 100 M 429-040 1 / 246 150 M 429-060 1 / 28 200
M 829-005 100 / 500M 829-007 50 / 300M 829-010 25 / 150M 829-012 10 / 80M 829-015 10 / 70M 829-020 10 / 50M 829-025 5 / 20M 829-030 5 / 15M 829-040 1 / 12M 829-060 1 / 2M 829-080 1 / 1
REDUCERCOUPLING
Soc
Size Size Part No. Std Pkg Part No. Std Pkg(In.) (mm) Bag/Case Bag/Case
SCHEDULE 40 SCHEDULE 80
¾ x ½ 20 x 15 M 429-101 100 / 3001 x ½ 25 x 15 M 429-130 50 / 5001 x ¾ 25 x 20 M 429-131 50 / 2001¼ x 1 32 x 25 M 429-168 25/ 1501½ x 1 40 x 25 M 429-211 25 / 1501½ x 1¼ 40 x 32 M 429-212 10 / 1502 x 1¼ 50 x 32 M 429-250 10 / 402 x 1½ 50 x 40 M 429-251 10 / 503 x 2 80 x 50 * 429-338 5 / --4 x 2 100 x 50 * 429-420 5 / --4 x 3 100 x 80 * 429-422 5 / –2½ x 2 65 x503 x 2½ 80 x 654 x 2½ 100 x65
M 829-251 10 / 50M 829-338 5 / 25
M 829-421 1 / 15M 829-292 10 / 40M 829-339 5 / 25M 829-422 1 / 15
* Trading Items
Size Size Part No. Std Pkg Part No. Std Pkg(In.) (mm) Bag/Case Bag/Case
SCHEDULE 40
½ 15 M 420-005 -- / 200¾ 20 M 420-007 -- / 1001 25 * 420-010 10 / --1¼ 32 * 420-012 10 / --1½ 40 * 420-015 10 / --2 50 * 420-020 10 / --
CROSS - Soc
uPVC PRESSURE FITTINGSSCHEDULE 40 AS PER ASTM D-2466SCHEDULE 80 AS PER ASTM D-2467
REDUCERELBOW
Size Size Part No. Std Pkg Part No. Std Pkg(In.) (mm) Bag/Case Bag/Case
SCHEDULE 80
¾ x ½ 20 x 151 x ½ 25 x 151 x ¾ 25 x 20
M 806-101 50 / --M 806-130 25 / --M 806-131 25 / --
12
Size Size Part No. Std Pkg Part No. Std Pkg(In.) (mm) Bag/Case Bag/Case
SCHEDULE 80
½ 15 M 897-005 10 / 200¾ 20 M 897-007 10 / 1201 25 M 897-010 10 / 801¼ 32 M 897-012 10 / 501½ 40 M 897-015 10 / 802 50 M 897-020 5 / 302½ 65 5 / --3 80 5 / --4 100 5 / --6 150 3 / –
UNION Soc WithEPDM O- Ring Seal
Size Size Part No. Std Pkg Part No. Std Pkg(In.) (mm) Bag/Case Bag/Case
SCHEDULE 40 SCHEDULE 80
½ 15 M 335-005 100 / 1200¾ 20 M 335-007 50 / 3501 25 M 335-010 25 / 3501¼ 32 M 335-012 10 / 1001½ 40 M 335-015 10 / 1002 50 M 335-020 10 / 50
¾ x ½ 20 x 15 M 335-101 50 / 6002½ 653 804 100
M 835-005 100 / 600M 835-007 50 / 400M 835-010 25 / 200M 835-012 10 / 100M 835-015 10 / 80M 835-020 10 / 50M 835-025 10 / 30M 835- 030 10 / 20M 835-040 1 / 12
FEMALE ADAPTER - Soc x FBSP
* Trading Items
Industrial Applications
Size Size Part No. Std Pkg(In.) (mm) Bag/Case
SCHEDULE 80
M 836-005B 50 / 250M 836-007B 25 / 150M 836-010B 25/ 100M 836-012B 10 / 50M 836-015B 10 / 40M 836-020B 5 / 20M 836-101B 25 / 150
½ 15¾ 201 251¼ 321½ 402 50
¾ x ½ 20 x 15
BRASS MALEADAPTER- Soc x MBSP
BRASS FEMALEADAPTER -Soc x FBSP
Size Size Part No. Std Pkg Part No. Std Pkg(In.) (mm) Bag/Case Bag/Case
SCHEDULE 80
M 835-005B 25 / 100M 835-007B 25 / 100M 835-010B 25 / 50M 835-012B 10 / 40M 835-015B 10 / 30M 835-020B 5 / 15M 835-101B 25 / 100M 829-130B 25 / 100
½ 15¾ 201 251¼ 321½ 402 50
¾ x ½ 20 x 15 1 x ½ 25 x 15
MALE ADAPTER - Soc x MBSP
Size Size Part No. Std Pkg Part No. Std Pkg(In.) (mm) Bag/Case Bag/Case
SCHEDULE 40 SCHEDULE 80
½ 15 M 336-005 100 / 1500¾ 20 M 336-007 50 / 4001 25 M 336-010 50 / 5001¼ 32 M 336-012 10 / 3001½ 40 M 336-015 10 / 2002 50 M 336-020 10/ 1502½ 65 * 336-025 10 / --3 80 * 336-030 10 / --4 100 * 336-040 6 / --6 150 * 336-060 3 / --
¾ x ½ 20 x 15
M 836-005 100 / 600M 836-007 50 / 400M 836-010 50 / 250M 836-012 10 / 150M 836-015 10 / 100M 836-020 10 / 60M 836-025 5 / 25M 836-030 5 / 20M 836-040 1 / 15
M 836-101 50 / 1000
uPVC PRESSURE FITTINGSSCHEDULE 40 AS PER ASTM D-2466SCHEDULE 80 AS PER ASTM D-2467
13
Size Size Part No. Std Pkg Part No. Std Pkg(In.) (mm) Bag/Case Bag/Case
SCHEDULE 40 SCHEDULE 80
¾ x ½ 20 x 15 M 437-101 100 / 8001 x ½ 25 x 15 M 437-130 50 / 4001 x ¾ 25 x 20 M 437-131 50 / 4001¼ x ½ 32 x 15 M 437-166 25 / 2001¼ x ¾ 32 x 20 M 437-167 25 / 2001¼ x 1 32 x 25 M 437-168 25 / 4001½ x ½ 40 x 15 M 437-209 25 / 3501½ x ¾ 40 x 20 M 437-210 25 / 1751½ x 1 40 x 25 M 437-211 25 / 3501½ x 1¼ 40 x 32 M 437-212 25 / 3002 x ½ 50 x 15 M 437-247 10 / 1002 x ¾ 50 x 20 M 437-248 10 / 1002 x 1 50 x 25 M 437-249 10 / 1002 x 1¼ 50 x 32 M 437-250 10 / 1002 x 1½ 50 x 40 M 437-251 10 / 1002½ x 1¼ 65 x 32 M 437-290 5 / 252½ x 1½ 65 x 40 M 437-291 5 / 502½ x 2 65 x 50 M 437-292 5 / 503 x 1½ 80 x 40 M 437-337 5 / 353 x 2 80 x 50 M 437-338 5 / 353 x 2½ 80 x 65 M 437-339 5 / 354 x 2 100 x 50 M 437-420 5 / 204 x 2½ 100 x 65 M 437-421 5 / 104 x 3 100 x 80 M 437-422 5 / 206 x 3 150 x 80 * 437-530 3 / --6 x 4 150 x 100 * 437-532 3 / --8 x 6 200 x 150 * 437-585 1 / –
M 837-101 100 / 300M 837-130 50 / 400M 837-131 50 / 400M 837-167 25 / 250M 837-166 25 / 250M 837-168 25 / 250M 837-209 25 / 150M 837-210 25 / 150M 837-211 25 / 150M 837-212 25 / 150M 837-247 10 / 100M 837-248 10 / 100M 837-249 10 / 100M 837-250 10 / 100M 837-251 10 / 100M 837-290 5 / 50M 837-291 5 / 50M 837-292 5 / 50M 837-337 5 / 35M 837-338 5 / 35M 837-339 5 / 35M 837-420 5 / 20M 837-421 5 / 20M 837-422 5 / 20
M 837-532 1 / 6M 837-585 1 / 3
REDUCER BUSHING(Flush Style)
BALL VALVE-Soc
Size Size Part No. Std Pkg Part No. Std Pkg(In.) (mm) Bag/Case Bag/Case
SCHEDULE 40
½ 15 * 2622-005 25 / --¾ 20 * 2622-007 25 / --1 25 * 2622-010 10 / --1¼ 32 * 2622-012 10 / --1½ 40 * 2622-015 10 / --2 50 * 2622-020 10 / --2½ 65 * 2622-025 5 / --3 80 * 2622-030 3 / --4 100 * 2622-040 1 / --6 150 * 2622-060 1 / --
* Trading Items
Size Size Part No. Std Pkg Part No. Std Pkg(In.) (mm) Bag/Case Bag/Case
SCHEDULE 40 SCHEDULE 80
½ 15 M 447-005 100 / 1000¾ 20 M 447-007 100 / 500 1 25 M 447-010 50 / 3001¼ 32 M 447-012 50 / 1501½ 40 M 447-015 10 / 2502 50 M 447-020 10 / 802½ 65 M 447-025 5 / 503 80 M 447-030 5 / 254 100 M 447-040 1 / 156 150 * 447-060 1 / –
M 847-005 100 / 800M 847-007 100 / 500M 847-010 50 / 300M 847-012 25 / 150M 847-015 10 / 100M 847-020 10 / 70 * 847-025 5 / -- * 847-030 5 / -- * 847-040 5 / -- * 847-060 1 / --
CAP - Soc
uPVC PRESSURE FITTINGSSCHEDULE 40 AS PER ASTM D-2466SCHEDULE 80 AS PER ASTM D-2467
Size Size Part No. Std Pkg Part No. Std Pkg(In.) (mm) Bag/Case Bag/Case
SCHEDULE 40
½ 15 * 448-005 50 / --¾ 20 * 448-007 25 / -- 1 25 * 448-010 25 / --1¼ 32 * 448-012 10 / --1½ 40 * 448-015 10 / --2 50 * 448-020 10 / --2½ 65 * 448-025 10 / --3 80 * 448-030 10 / --
CAP Fipt
Size Size Part No. Std Pkg Part No. Std Pkg(In.) (mm) Bag/Case Bag/Case
SCHEDULE 40
½ 15 T 2622-005 1/48¾ 20 T 2622-007 1/361 25 T 2622-010 1/161¼ 32 T 2622-012 1/101½ 40 T 2622-015 1/82 50 T 2622-020 1/6
BALL VALVE(ASTRAL)
14
uPVC PRESSURE FITTINGS
Size Size Part No. Std Pkg(In.) (mm) Bag/Case
½ 15 M-PLUG - 12 300I
END PLUG THREADS
Size Size Part No. Std Pkg(In.) (mm) Bag/Case
½ 15 M 470-005 10/80 ¾ 20 M 470-007 10/601 25 M 470-010 10/401¼ 32 M 470-012 10/301½ 40 M 470-015 10/202 50 M 470-020 5/15
TANK ADAPTER
½ 15 M 854-005 10/120¾ 20 M 854-007 10/801 25 M 854-010 10/601¼ 32 M 854-012 5/501½ 40 M 854-015 5/352 50 M 854-020 5/252½ 65 M 854-025 1/153 80 M 854-030 1/124 100 M 854-040 1/86 150 M 854-060 1/38 200 M 854-080 1/1
Size Size Part No. Std Pkg(In.) (mm) Bag/Case
CL 150
VANSTONE FLANGE - Soc
Size Size Part No. Std Pkg(In.) (mm) Bag/Case½ 15 PVC 9120 M 80¾ 20 PVC 9340 M 601 25 PVC 9100 M 401¼ 32 PVC 9105 M 301½ 40 PVC 9106 M 202 50 PVC 9200 M 15
METAL STRAP
Size Size Part No. Std Pkg(In.) (mm) Bag/Case
CL 150
2½ 65 * 851-025 5 / --3 80 M 851-030 1 / 124 100 M 851-040 1 / 86 150 * 851-060 1 / --
ONE PIECEFLANGE - Soc
* Trading Items
N.B. : Astral have range of trading fittings from ½" to 12" other than mentioned in this catalogue and can be made available upon request.
Size Size Part No. Std Pkg(In.) (mm) Bag/Case
CL 150
2½ 65 * 856-025 5 / --3 80 M 856-030 1 / 104 100 M 856-040 1 / 66 150 * 856-060 1 / --
VANSTONEFLANGE - Spig
Size Size Part No. Std Pkg(In.) (mm) Bag/Case
CL 150
2½ 65 * 853-025 5 / --3 80 M 853-030 1 / 204 100 M 853-040 1 / 176 150 * 853-060 1 / --
BLIND FLANGE
Application in Swimming pool lines
15
Above data is based upon information provided by the raw material manufacturers. It should be used only as a recommendation and not as a guarantee of performance.
Property Units PVC ASTM No.Specific Gravity g/cc 1.41 - 1.46 D 792Tensile Strength (73°F) PSI 7,200 D 638Modulus of Elasticty in Tension (73°F) PSI 4,60,000 D 638Flexural Strength (73°F) PSI 13,200 D 790Izod Impact (notched at 73°F) ft lb/in. 0.65 D 256Hardness (Durometer D) --- 80 ± 3 D 2240Hardness (Rockwell R) --- 110 - 120 D 785Compressive Strength (73°F) PSI 9,000 D 695Hydrostatic Design Stress PSI 2,000 D 1598
-5Coefficient of Linear Expansion in./in./°F 3.1 x 10 D 696Heat Deflection Temperature at 66 psi degrees °F 165 D 648Coefficient of Thermal Conductivity BTU/hr/sq. ft/°F/in. 1.2 C 177Specific Heat BTU/F/lb 0.25 D 2766Limiting Oxygen Index % 43 D 2863Water Absorption (24 hrs at 73°F) % weight gain 0.05 D 570Cell Classification-Pipe --- 12454-B D 1784Cell Classification-Fittings --- 12454-B D 1784
PHYSICAL PROPERTIES OF PVC MATERIALS
* Trading Items
uPVC PRESSURE PIPESSCHEDULE 40 & SCHEDULE 80
AS PER ASTM D-1785
3MTR½ 15 P40-012 50¾ 20 P40-034 301 25 P40-001 201¼ 32 P40-114 151½ 40 P40-112 102 50 P40-002 82½ 65 P40-212 53 80 P40-003 34 100 P40-004 26 150 P40-006 18 200 P40-008 110 250 P40-100 112 300 P40-120 1
Size Size Part No. Std Pkg(In.) (mm) Bag
Part No. Std PkgBag
SCHEDULE 40 SCHEDULE 80
3MTRP80-012 50P80-034 30P80-001 20P80-114 15P80-112 10P80-002 8P80-212 5P80-003 3P80-004 2P80-006 1P80-008 1P80-100 1P80-120 1
uPVC SOLVENT CEMENT
PRIMER P 70
Std PkgPart No. Case
118 ML * 1205 24237 ML * 1206 24473 ML * 1207 12946 ML * 1208 12
AS PER ASTM D-2564
MEDIUMBODIED PVC 705
Std PkgPart No. Case
50 ML * 50 705 48118 ML * 118 705 24237 ML * 237 705 24473 ML * 473 705 12946 ML * 946 705 12
AS PER ASTM D-2564
HEAVY BODIED PVC 717
Std PkgPart No. Case
118 ML * 118 717 24237 ML * 237 717 24473 ML * 473 717 12946 ML * 946 717 12
AS PER ASTM D-2564
16
• Observe all safety precautions.• Systems should be installed in a good and workmanlike manner
consistent with normal industry standards and in conformance with all local plumbing, fire and building code requirements. Failure to follow proper installation practices, procedures or techniques can result in system failure, property damage or personal injury.
REMOVE BURR & BEVEL• Remove all burr from inside and outside of pipe with a knife-edge, file or deburring tool. Chamfer
O O(bevel) the end of the pipe 10 - 15
• Remove surface dirt, grease or moisture with a clean dry cloth.CLEAN22
APPLICATOR
• Use an applicator that is one half the pipe diameter.• Too large an applicator will force excessive cement in to the inside of small diameter fittings. Too small
an applicator will not apply sufficient cement to large diameter systems.44
CUT PIPE• Cut pipe square. As joints are sealed at the base of the fitting socket. An angled cut may result in joint
failure.• Acceptable tools include miter saw, mechanical cut off saw or wheel cutter. Wheel type cutters must
employ a blade designed for plastics. 11• With light pressure, pipe should go one third to one half of the way into the fitting socket. Pipes and
Fittings that are too tight or too loose should not be used.
DRY FIT
33CEMENT
• Apply a full even layer of cement to the outside of a pipe and medium layer of cement to the inside of a fitting. 55
uPVC cement for SCH 40 and interference fitPipe Size (In.) Cement Type Min. Vis.(cP) IPS -weld
mm On½ - 2 Medium bodied 500 705
15 - 50 mm
2½ - 12 Heavy bodied 1600 71765 - 300 mm
uPVC cement for SCH 80 and non interference fitPipe Size (In.) Cement Type Min. Vis.(cP) IPS -weld
mm On½ - 1¼ Medium bodied 500 705
15 - 32 mm
1½ - 12 Heavy bodied 1600 71740 - 300 mm
• Assemble pipe and fitting socket till it contacts socket bottom. Give pipe a quarter turn. Hold pipe and fitting together until th pipe dose not back out.
• Remove excessive cement from the exterior. A properly made joint will show a continuous bead of cement around the perimeter.
JOIN PIPE AND FITTINGS
66N.B. : Primers must be used in solvent cement joints of uPVC plastic pipe and fittings for size above 2".
INSTALLATION PROCEDURES• Pipes and fittings should be used for their intended purpose as
defined by local plumbing and building codes and the applicable ASTM standards.
• Follow manufacturers’ instructions for all related products.
17
Temperature°CNom.Pipe Size
½ 15 4½ 4½ 4 2½ 2½¾ 20 5 4½ 4 2½ 2½1 25 5½ 5 4½ 3 2½1¼ 32 5½ 5½ 5 3 31½ 40 6 5½ 5 3½ 32 50 6 5½ 5 3½ 32½ 65 6½ 6 5½ 4 33 80 7 7 6 4 3½4 100 7½ 7 6½ 4½ 46 150 8½ 8 7½ 5 4½8 200 9½ 9 8½ 5½ 5
10 250 10½ 9½ 9 6½ 5½12 300 12 10½ 9½ 7 6
(In.) (mm) 15.5 26.6 37.7 48.8 60
Recommended Support spacing (in feet)Schedule - 40
Temperature°CNom.Pipe Size
Recommended Support spacing (in feet)Schedule - 80
½ 15 5 4½ 4 3 2½¾ 20 5½ 5 4½ 3 2½1 25 6 5½ 5 3½ 31¼ 32 6 6 5½ 3½ 31½ 40 6½ 6 5½ 3½ 3½2 50 7 6½ 6 4 3½2½ 65 7½ 7½ 6½ 4½ 43 80 8 7½ 7 4½ 44 100 9 8½ 7½ 5 4½6 150 10 9½ 8½ 6½ 5½8 200 11 10 9½ 7½ 6
10 250 12½ 11 10½ 8 712 300 13 12 10½ 7½ 6½
½ (In.) (mm) 15.5 26.6 37.7 48.8 60
SUPPORT SPACING FORuPVC PIPE
NOTE : The above information provides general guidelines. It should be used only as a reference and not as a guarantee of performance. Specific installation instructions and techinques may be required as a result of local plumbing and building codes, engineering specifications and instructions.
Recommended initial set times.
Recommended initial cure times.
JOINT CURING
Adequate supports for any piping system is a matter of great importance. In practice, support spacings are a function of
pipe size operating temperatures, the location of heavy valves or fittings and the mechanical properties of the pipe material.
To ensure the satisfactory operation of a ASTRAL Aquarius uPVC piping system, the location and type of hangers should be carefully considered. Hangers should not compress, distort, cut or abrade the piping.
All piping should be supported with an approved hanger at intervals sufficiently close to maintain correct pipe alignment and to prevent sagging or geade reversal. Pipe should also be supported at all branch ends and at all changes of direction. Support trap arms as close as possible to the trap. In keeping with good plumbing practices support and brace all closet bends and fasten closet flanges.
(1) Concentrated loads should be supported directly so as to eliminate high stress concentrations. Should this be impractical then the pipe must be supported immediately adjacent to the load.
(2) In systems where large fluctuations in temperature occur, allowances must be made for expansion and contraction of the piping system. Since changes in direction in the system are usually sufficient to allow for expansion and contraction hangers must be placed so as not to restrict this movement.
(3) Since plastic pipe expands or contracts approximately five times greater than those of steel, hangers should not restrict this movement.
(4) Hangers should provide as much bearing surface as possible. To prevent damage to the pipe, file smooth any sharp edges or burrs on the hangers or supports.
(5) Support spacing for horizontal piping systems is determined by the maximum operating temperature the system will encounter. The piping should be supported on uniform centers with supports that do not restrict the axial movement.
(6) For vertical lines, it is recommended that an engineer should design the vertical supports according to the vertical load involved.
18
CA
UT
ION
: F
low
velo
city
should
not
exc
eed 5
feet
per
seco
nd.
PV
C p
ipe c
annot
be u
sed f
or
com
pre
ssed a
ir s
erv
ice.
19
CA
UT
ION
: F
low
vel
ocity
sho
uld
not
exce
ed 5
fee
t pe
r se
cond
. P
VC
pip
e ca
nnot
be
used
for
com
pres
sed
air
serv
ice.
Guide-hanger
FixedPoint
Loop
20
TESTING PRESSURE SYSTEM1. Prior to testing, safety precautions should be instituted to
protect personnel and property in case of test failure.
2. Conduct pressure testing with water. DO NOT USE AIR OR
OTHER GASES for pressure testing.
3. The piping system should be adequately anchored to limit
movement. Water under pressure exerts thrust forces in
piping systems. Thrust blocking should be provided at changes
of direction, change in size and at dead ends.
4. Please refer tables given for initial set & cure times before
pressure testing.
5. The piping systems should be slowly filled with water, taking
care to prevent surge and air entrapment. The flow velocity
should not exceed feet per second.
6. All trapped air must be slowly released. Vents must be
provided at all high points of the piping system. All valves and
air relief mechanisms should be opened so that the air can be
vented while the system is extremely dangerous and it must
be slowly and completely vented prior to testing. For sizes 4"
& above, ASTRAL recommends to use automatic air relief
valves at every 300-400mtr. distance & at furthest & highest
points of pipeline to avoid any damage to the piping system.
7. The piping system can be pressurized to 125% of its designed
working pressure. However care must be taken to ensure the
pressure does not exceed the working pressure of the lowest
rated component in the system (valves, unions, flanges,
threaded parts etc.)
8. The pressure test should not exceed one hour. Any leaking
joints or pipe must be cut out and replaced and the line
recharged and retested using the same procedure.
EXPANSION AND CONTRACTIONOF uPVC PIPE
uPVC pipes, like other piping materials, undergo length changes as a result of temperature variations above and below the installation temperature. They expand and contract 4.5 to 5 times more than steel or iron pipe. The extent of the expansion - contraction depends upon the coefficient of linear expansion of piping material. The length of pipe between directional changes, and the temperature differential.
-5 The coefficient of thermal expansion (Y) for uPVC is 3.1 x 10in./in./°F.
The amount of expansion or contraction can be
calculated using the following formula :
The length of leg "R" can be determined by using the following formula to ensure that it is long enough to absorb the expansion and contraction movement without damage. The length of leg "A" should be 1/2 the length of leg "R"
There are several ways to compensate for expansion and contraction. The most common methods are :1. Expansion loops which consist of pipe and 90° elbows2. Piston type expansion joints*3. Flexible bends*4. Bellows and rubber expansion joints** The manufacturers of these devices should be contacted to determine the suitability of their products for the specific application.Expansion loops are a simple and convenient way to compensate for expansion and contraction when there is sufficient space for the loop in the piping system. A typical expansion loop design is shown below.
21
When installing the expansion loop, no rigid or restraining
supports should be placed within the leg lengths of the loop. The
loop should be installed as closely as possible to the mid-point
between anchors. Piping support guides should restrict lateral
movement and direct axial movement into the loop. Lastly, the
pipe and fittings should be solvent cemented together, rather than
using threaded connections.
Compensation for expansion and contraction in underground
application is normally achieved by snaking the pipe in the trench.
Proper trenching and burial procedures must be followed to
protect the piping system.
The table below shows recommended offsets and loop lengths
for piping up to 2½" nominal size.
LOOP LENGTH
2 LOOP LENGTHS OF PIPE
OFFSETOFFSET
PIPE
TRENCHCENTERLINE
1. Even though sub-soil conditions vary widely from place to place, the pipe backfill should be stable and provide protection for the pipe.
2. The pipe should be surrounded with a granular material which is easily worked around the sides of the pipe Backfilling should be performed in layer of 6 inch with each layer being sufficiently compacted to 85% to 95% compaction.
3. A mechanical tamper is recommended for compacting sand and gravel backfill which contain a significant proportion of fine grained material, such as silt and clay. If a tamper is not available, compacting should be done by hand.
4. The trench should be completely filled. The back fill should be placed and spread in fairly uniform layers to prevent any unfilled spaces or voids. Large rocks, stones, frozen clods, or other large debris should be removed. Heavy tampers or rolling equipment should only be used to consolidate only the final backfill.
BEDDING AND BACKFILLING
uPVC pipes and fittings can be installed underground, Since these piping systems are flexible systems, proper attention should be given to burial conditions. The stiffness of the piping system is affected by sidewall support, soil compaction, and the condition of the trench, Trench bottoms should be smooth and regular in either undisturbed soil or a layer of compacted backfill. Pipe must lie evenly on this surface throughout the entire length of its barrel, Excavation, bedding and backfill should be in accordance with the provision of the local Plumbing Code having jurisdiction.
UNDERGROUND INSTALLATION
22
The pipe should be handled with reasonable care. Because thermoplastic pipe is much lighter in weight than metal pipe. There is sometimes a tendency to throw it around. This should be avoided.
The pipe should never be dragged or pushed from a truck bed. Pallets for pipe should be removed with a fork lift. Loose pipe can be rolled down timbers, as long as the pieces do not fall on each other or on any hard or uneven surface. In all cases, severe contact with any sharp objects (rocks, angle irons, forks on forklifts, etc.) should be avoided.
HANDLING
STORAGEIf possible, pipe should be stored inside. When this is not
possible, the pipe should be stored on level ground which is dry and free from sharp objects. If different schedules of pipes are stacked together, the pipe with the thickest walls should be at the bottom.
The pipe should be protected from the sun and be in an area with proper ventilation. This will lessen the effects of ultraviolet rays and help prevent heat built-up.
If the pipe is stored in racks, it should be continuously supported along its length. If this is not possible, the spacing of the supports should not exceed three feet (3’).
When storage temperatures are below 0°C (32°F), extra care should be taken when handling the pipe. This will help prevent any problems which could be caused by the slightly lower impact strength of uPVC pipe at temperature below freezing.
NOT FOR USE WITHCOMPRESSED AIR OR GASES
ASTRAL POLY TECHNIK LTD. DOES NOT RECOMMEND the
use of thermoplastic piping products for systems to transport or
store compressed air or gases, or the testing of thermoplastic
piping systems with compressed air or gases in above as well as
below ground locations, The use of ASTRAL Aquarius product in
compressed air or gas systems automatically void any warranty for
such products and its use against our recommendation is entirely
the responsibility and liability of the installer.
WARNING : DO NOT USE COMPRESSED AIR OR GAS TO TEST ANY
PVC THERMOPLASTIC PIPING PRODUCT OR SYSTEM, AND DO
NOT USE DEVICES PROPELLED BY COMPRESSED AIR OR GAS TO
CLEAR SYSTEMS. THESE PRACTICES MAY RESULT IN EXPLOSIVE
FRAGMENTATION OF SYSTEM PIPING COMPONENTS CAUSING
SERIOUS OR FATAL BODILY INJURY.
FREQUENTLY ASKEDQUESTIONS ABOUTASTRAL AQUARIUS®
1. Why Lead Free ?
2. What is the expected life of a ASTRAL Aquarius System?
3. Will ASTRAL Aquarius System save me money ?
4. Will ASTRAL Aquarius System offer a financial advantage to
owners in terms of utilities expense?
5. Must I use plastic insulators wherever uPVC passes through
a stud ?
Lead is a metal with no known biological benefit to humans.
Too much lead can damage various systems of the body
including the nervous and reproductive systems and the
kidneys, and it can cause high blood pressure and anemia.
Lead accumulates in the bones and lead poisoning may be
diagnosed from a blue line around the gums. Lead is
especially harmful to the developing brains of fetuses and
young children and to pregnant women. Lead interferes with
the metabolism of calcium and Vitamins D. High blood lead
levels in children can cause consequences which maybe
irreversible including learning disabilities, behavioral
problems, and mental retardation. At very high levels, lead
can cause convulsions, coma and death. Lead can be
dissolved in water when lead pipes are used for
transportation of water. So use of such pipes may be harmful
to human being. Hence lead free plumbing system is most
favoured for potable water transportation.
ASTRAL Aquarius uPVC system design & standards
incorporate significant engineering safety factors which
should translate to a long service life ASTRAL Aquarius
System have a design service life span of 50 years. ASTRAL
Aquarius System is not susceptible to corrosion, scale build
up or electrolysis in areas where water, solid and / or
atmospheric conditions are aggressive. ASTRAL firmly
believes that the system will provide a service life as long or
longer than alternative materials in the market.
Yes, As a professional, you will quickly realize that uPVC can
be installed at least 25% more quickly than metal systems.
Financial savings are also realized with regard to lower tool
costs and insurance advantage. Even considering the
frequent rise and fall of the metal price structure, uPVC offers
a continuing materials cost advantage, as much as a full
50- 60 % material savings today.
Yes, the thermal conductivity of a metal system is 2500 times
that of a uPVC system. The improved insulating
characteristics associated with uPVC can generate long-term
saving for energy conscious homeowner or tenant. ASTRAL
Aquarius will hold the temperature of water for a much
longer period of time than metal tubing.
23
polymer chains to any significant extent after outdoor
exposure, being mainly limited to a surface discoloration effect
only.There is a loss of Impact resistance due to impact modifiers
losing efficiency.This may even result in increased modulas.There is no significant loss in stress bearing capacity Impact
resistance mainly an Installation issue(before any U.V. exposure)Still if a portion of the piping system will be left exposed to
U.V.light, a standard grade of exterior, latex paint (water base)
will protect the pipe adequately.
Practically, Yes. It is very much possible to use ASTRAL Aquarius
at a temperature around 10 - 15 °C. Normal temperature range
of uPVC compound material is 23°C to 60 °C. As temperature
decrease beyond 23°C, uPVC becomes brittle like any other
thermoplastic material. So its impact properties decrease as
temperature decrease but there is no reduction in hydrostatic
strength of material at lower temperatures so it can be used at
lower temperatures but very sound engineering design
considerations required at a such low temperatures to
eliminate water hammers & impact issues.
The tendency of sound is to travel in the material with fastest
possible velocity.This means in metal system, the sound travels in metal
because the velocity of sound in metal is higher than that of in
water and create noise emissions. While in uPVC system, noise
will travel in water because the velocity of sound in water is
higher than that of in uPVC. So uPVC systems are as quiet as
physically possible.
Scale built up is a function of the roughness of the pipe, as
measured by the Hazen - Williams “C” factor, used in the
Hazen Williams formula for calculating friction head losses in
piping system.Higher value for C - Less friction,
- Less head loss.with metal systems, once corrosion starts “C” factor will
greatly reduce which result in head loss and scale built up.
With ASTRAL Aquarius uPVC, there is no corrosion and hence
scale built up is inhibited.
IPS (Iron Pipe Size) & CTS (Copper Tube Size) are most widely
used systems in plumbing market. Therefore changeability of
one to another is very much important. ASTRAL has
understood this requirement of market and hence developed
special transition fittings. These fittings will connect the IPS
System (SCH 40 & SCH 80) to CTS system (SDR 11 & SDR 13.5).
These transition fittings are joined with one step solvent
cement, which gives customer a very fast, efficient & simple
solution to join both systems. Available sizes are from 15 mm
(½”) to 50 mm (2”).
10. Is it possible to use ASTRAL Aquarius System at temperature
around 10-15°C?
11. What about the noise emissions compare to metallic system?
12. What about scale build up?
13. Is it possible to connect IPS system with CTS system?
Technically, no such provision need be made when passing
through wood stud. When passing through metal studs some
form of protection must be used to protect the pipe from
abrasion and to prevent noise. This protection may come from
plastic insulation rubber grommets, pipe insulation or similar.
ASTRAL always recommends use of solvent cement which is
specifically manufactured to meet the requirements of ASTM D
2564. All purpose cements should not be utilized. Primers
manufactured for uPVC pipe is acceptable. For more details,
efer installation procedure of this manual.
Most cracks are initiated by rough handling. This handling can
occur during transportation, while being inventoried at the
wholesaler, or while at the job sight. Also, Fine cracks can be
caused by cutting the pipe with dull or damaged ratchet
cutters. The vast majority cracks occur during colder weather
months when temperatures are below 10°C, uPVC like most
other plastics such as PP, PEX, CPVC, may become somewhat
brittle and should be handled more carefully.To reduce problems resulting from cracked product, several
measures can be initiated :Educate your installers. Make them aware of the potential
problems and instruct them to handle uPVC in a
appropriate way.Use a saw or a circular tubing cutter with a
Tests performed at respected universities and independent
laboratories confirm that uPVC is superior to metal systems in
terms of water quality effects and "no more toxic than wood"
in fire.ASTRAL Aquarius uPVC system is manufactured from a
compound which is lead free and hence most favoured system
in terms of health and safety. LOI of uPVC is 45, which means
uPVC is not reality burnable in atmosphere. Once the burning
source is removed, It stops burning.
- Effect of U.V. On polymers“U.V. acts as a strong catalyst for the oxidations process which breaks down the polymer chains, leading weakness in
the pipes & fittings and to loss of hydrostatic strength. ”Above
effect is very much possible with materials like PP & PE.
But for uPVC main process is dehydrochlorination and not
oxidation. This dehydrochlorination does not break down the
6. Should specific type of Primers and solvent cements be used
on uPVC system?
7. I have been told that uPVC tubing ends may split during
installation. Why should this occur? How can these cracks be
prevented?
A.
B.
C.
D.
8. What about health, safety & fire toxicity issues?
9. Is ASTRAL Aquarius System resistant to U.V. exposure ?
plastic tubing
blade to cut your pipe to length.Inspect pipe ends thoroughly prior to making a joint.
Should a crack be evident, cut off any split portion before
proceeding.During cold weather, gripping the tubing highly around the
area to be cut for about 10 seconds prior to making the cut
will warm the tubing and reduce possible problems.
NOTES :
All information contained in this manual is given in good faith and believed to be accurate and reliable. But because of many factors which are outside our knowledge and control and affect use of product, no warranty is given or is to be implied with respect to such information, nor we offer any warranty of immunity against patent infringement. No responsibility can be accepted for any error, omissions or incorrect assumptions. Any specification can change without prior notice.