Aqua-Hot Hydronic Heating System Owner’s Manual 07/04 ® Aqua-Hot™ Motor Coach Heating System Owner's Manual 08/03 OWNER’S MANUAL Model Number AHE-100-04S - 12 VDC. AHE-130-04X - 12 VDC.

Aqua-Hot Owner's Manual

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Aqua-Hot Hydronic Heating System Owner’s Manual 07/04®

Aqua-Hot™ Motor Coach Heating System Owner's Manual 08/03

OWNER’S MANUALModel NumberAHE-100-04S - 12 VDC.AHE-130-04X - 12 VDC.

Aqua-Hot Hydronic Heating System Owner’s Manual 07/04®

Vehicle Systems, Inc.Warranty Department15549 East Highway 52Ft. Lupton, CO 80621

Please Mail To:

OWNER’S INFORMATIONOwner’s Name:

Address:

City: State: Zip Code:

Telephone:

E-mail Address:

Motorhome Model:

Date of Purchase (Motorhome):

Aqua-Hot Model No. (reference Figure 1 “Marking Plate”):

Aqua-Hot Serial No. (reference Figure 1 “Marking Plate”):

Vehicle Systems’ Warranty Department15549 East Highway 52Ft. Lupton, CO 80621

NI LIAM DNA EREH TUC

Aqua-Hot Hydronic Heating System Owner’s Manual 07/04®

� � � � � � � � �������TABLE OF CONTENTS

Section 1 Overview Page

1.0 Aqua-Hot Overview 1 1.1 Marking Plate 2 1.2 Aqua-Hot Model Differentiation 3

Section 2 Activating the Aqua-Hot Heating Systems’ Heat Sources

2.1 Diesel-Burner 3 2.2 Electric Heating Element AHE-100-04S Model 4 2.3 Electric Heating Element(s) AHE-130-04X Model 4

Section 3 Operating Instructions

3.1 Zone Thermostat(s) Operation 5 3.2 Using the Domestic Hot Water System 6 3.3 Using the Engine Preheat System 6 3.4 Diesel-Burner Component Overview 7 3.5 Diesel-Burner Operational Flow Chart 7 3.6 Precautions 8

Section 4 Maintenance

4.1 Maintenance Schedule 9

Section 5 Winterization

5.1 Domestic Hot Water System 10

Section 6 Troubleshooting

6.1 General Information 11 6.2 Electronic Controller Diagnostic 11

Referenced Illustrations Figure 1: Aqua-Hot Hydronic Heating System and Inclusive Components 2 Figure 2: Marking Plate 2 Figure 3: Aqua-Hot Interior Switch Panel 6 Figure 4: Diesel-Burner Components 7 Figure 5: Diesel-Burner Components Requiring Annual Maintenance 9 Figure 6: Electronic Controller 11

Aqua-Hot Hydronic Heating System Owner’s Manual 07/04® Page 1

SECTION 1: OVERVIEW

Aqua-HotOverview,continued

NOTE: This Aqua-Hot product utilizes an FDA approved GRAS Propylene Glycol (P.G.) based water and antifreeze solution. This P.G. based solution is a Boiler type anti-freeze, which is Generally Recognized as Safe (”GRAS”) by the FDA. For additional information regarding this GRAS antifreeze product, please contact the Technical Support Department at 1-800-685-4298 or visit the website at www.vehiclesys.com.

1.0 Aqua-Hot Overview

SECTION 1: OVERVIEW

Aqua-HotOverview The Aqua-Hot Heating System is an on-board Hydronic Heating

System (heating with hot water) that provides a continuous, on-demand supply of domestic hot water, as well as interior zone heating where and when it is needed. Both heating features are accomplished by a unique 12 Volt-DC Powered Diesel-Fired Burner and a minimum of one 120 Volt-AC Powered Electric Heating Element. (As the number of Electric Elements will vary between Aqua-Hot models, please reference page 5 to determine the particular model of Aqua-Hot employed.) These two heating sources maintain the temperature of the Aqua-Hot’s solution of water and antifreeze. In addition, the Aqua-Hot has been designed to preheat the vehicle’s engine prior to starting. This preheat feature provides an easy engine start-up whenever cool weather conditions are present. Be sure to review Figure 1 for a complete component overview.

SECTION 1: OVERVIEW

Aqua-Hot Hydronic Heating System Owner’s Manual 07/04® Page 2

SECTION 1: OVERVIEW

Aqua-HotOverview,continued

ELECTRONIC CONTROLLER

���������R

toH

dloC

ExpansionTank

CirculationPump #3

Engine PreheatCirculation

Pump

Diesel-BurnerHead

Engine CoolantSupply

Hot WaterOutlet

(Domestic Water)

Diesel FuelSupply

Diesel FuelReturn

Pressure-ReliefValve

Cold WaterInlet

(Domestic Water)

EngineCoolantReturn

Diesel-BurnerControl

Unit

MixerValve

Electric HeatingElement Access

Panel

Fill / RadiatorCap

VAC AccessPanel

VAC ServiceInput

ThermostatAccess Panel

MarkingPlates

Hour Meter

Heating ZonesStatus

#5

#4

#3

#2

#1

Electric HeatingElement Status

Low Voltage

Reset

Low Tank-LevelCutoff

Heating Status

Engine PreheatPump

Low BatteryVoltage Fault

Low TempCutoff Status

Overload Fault

Pump #2

Pump #1

Pump #3

Diesel-BurnerStatus

Motor Coach Heating Specialists

ElectronicController

Switch Panel

CirculationPump #2

CirculationPump #1

Heating ZonesSupply and Return

Ports

Boiler TankDrain Valve

Diesel Electric EnginePreheat

������������������

Figure 1

1.1 Marking PlateMarkingPlate

AHE-100 02S 12 VDC / 170 Watts

Model Number Diesel-Burner / DC Power

Serial Number Electric Heating Element / AC Power

Manufactured Date Fuel Type / Firing Rate

02-637 120 VAC, 60 Hz / 1.65 kW

06-02 DIESEL / 50,000 BTU

R

Testing Engineers International

Listing No. 02L02

Complies with the requirements of UL 307A

Made in U.S.A.

For Installation Only in Compartment Completely Closed Off from Living Quarters and Accessible Only from the Outdoors.

Exhaust system MUST NOT terminate beneath the vehicle or under an openable window or vent.

Combustion Air MUST BE supplied from outside the vehicle.

CAUTION: This appliance operates on both AC and DC Electrical Power.

The AC Powered Electrical Heating Element can be wired using flexible nonmetallic cable (ROMEX). USE COPPER CONDUCTORS ONLY

Use 25 Amp fuse for over current protection for DC Power Supply.

Use 20 Amp Circuit Breaker for over current protection for AC Power Supply.

Mount Heater near a Bay / Storage Door so Access Cover can be easily removed.

Minimum Heater clearances Front (Decal Sides) - Open Access Back - 0 inches Top - 6 inches Install in strict compliance with local codes, NFPA 501c and manufacturer’s instructions.

For additional product installation information visit www.aqua-hot.com or call 1-800-685-4298

By Vehicle Systems, Inc. Ft. Lupton, CO 80621

Manufactured Date Box

Serial Number Box

Model Number Box

SECTION 1: OVERVIEW

Figure 2

SECTION 1: OVERVIEW

Aqua-Hot Hydronic Heating System Owner’s Manual 07/04® Page 3

1.2 Aqua-Hot Model Differentiation

SECTION 1: OVERVIEW

Aqua-HotModels Vehicle Systems, Inc. manufactures two individual models of the

Aqua-Hot Hydronic Heating System. The varying factor between the two models is the number of Electric Heating Elements featured. In order to determine which of the following Aqua-Hot models has been employed, locate the Marking Plate on the Heating System (reference Figures 1 and 2 for Marking Plate information) and view the model number.

AHE-100-04S:This model features a single 120 VAC/1650 Watt Electric Heating Element. Reference page 7 for operating instructions.

AHE-130-04X:This model features two 120 VAC/2000 Watt Electric Heating Elements. Reference page 8 for operating instructions.

SECTION 2: ACTIVATING THE AQUA-HOT’S HEAT SOURCES

Diesel-BurnerOperation

2.1 Activating the Diesel-Burner

Diesel-BurnerTurn the Diesel switch ON; reference Figure 3. This procedure willactivate the Diesel-Burner and the indicator light located on the Dieselswitch. Allow 10-20 minutes for the Aqua-Hot System to reach operatingtemperature. Please note that the Diesel-Burner is the primary heatsource for heating both the interior and the domestic hot water (such aswhen cool ambient temperatures exist and/or when there is a high de-mand for domestic hot water).

Please read the complete Owner’s Manual prior to operating your Aqua-Hot Heating System. Also, be sure to fill out and mail in your Owner’sInformation Card located at the front of this manual.

SECTION 1: OVERVIEW

Aqua-Hot Hydronic Heating System Owner’s Manual 07/04® Page 4

2.2 Activating the Electric Heating Element for the AHE-100-04S Model

SECTION 2: ACTIVATING THE AQUA-HOT’S HEAT SOURCES

ElectricElementOperationAHE-100-04S

Electric Heating ElementTurn the Electric switch ON; reference Figure 3. This procedure willactivate the 120 VAC Electric Heating Element and the indicator lightlocated on the Electric switch. Allow 1-2 hours for the Aqua-Hot System toreach operating temperature. Please note that the Electric HeatingElement is a secondary heat source for heating both the interior and thedomestic hot water during low heating demand situations (such as whenmoderate ambient temperatures exist and/or when there is a low demandfor domestic hot water).

NOTE: Both the Diesel-Burner and the Electric Heating Element arethermostatically controlled. Either, or both, heating sources willautomatically maintain the temperature of the Aqua-Hot's water andantifreeze solution between approximately 160-190 (+/- 5) degreesFahrenheit. To heat your motorhome / domestic hot water, simplychoose the desired heat source(s) and leave the switch(s) (i.e., Dieseland/or Electric) ON.

2.3 Activating the Electric Heating Element(s) for the AHE-130-04X Model

SECTION 2: ACTIVATING THE AQUA-HOT’S HEAT SOURCES

ElectricElementOperationAHE-130-04X

Electric Heating Element(s)Low:Turn the Electric switch ON in conjunction with the High / Low switchplaced in the LOW position; reference Figure 3. This procedure willactivate one of the two 120 VAC Electric Heating Elements and theindicator lights located on both the Electric and High / Low switches. Allow1-2 hours for the Aqua-Hot System to reach operating temperature.High:Turn the Electric switch ON in conjunction with the High / Low switchplaced in the HIGH position; reference Figure 3. This procedure willactivate both of the 120 VAC Electric Heating Elements and the indicatorlights located on both the Electric and High / Low switches. Allow 0.5-1hour for the Aqua-Hot System to reach operating temperature.

NOTE: In order to operate both Electric Heating Elements, you will eitherneed a 50-AMP Shore Power electrical source, or your Generator must becapable of producing the necessary VAC electrical power requirements. Please contact the manufacturer of your specific motorhome for informationregarding the specifics of your motorhome’s electrical system.

SECTION 2: ACTIVATING THE AQUA-HOT’S HEAT SOURCES

Aqua-Hot Hydronic Heating System Owner’s Manual 07/04® Page 5

SECTION 3: OPERATING INSTRUCTIONS

ComfortControl

3.1 Zone Thermostat(s) Operation

Interior Room ThermostatsSimply adjust each Interior Room Thermostat to the desired temperature.Then, whenever an Interior Room Thermostat “calls-for-heat,” the Aqua-Hot’s Circulation Pump(s) and Interior Heat Exchanger Fans will beactivated. These devices together will supply warmth and comfort to eachinterior heating zone. Please contact your specific motorhomemanufacturer for the exact location of the Interior Room Thermostat(s).

Fresh Water Tank ThermostatSimply adjust the Thermostat (i.e., Bay Heating) to approximately 40degrees Fahrenheit. This will prevent freezing of the domestic waterstorage system. Please contact your specific motorhome manufacturerfor the exact location of the Fresh Water Tank Thermostat.

SECTION 3: OPERATING INSTRUCTIONS

3.2 Using the Domestic Hot Water System

When the Aqua-Hot is at operating temperature, the domestic water isautomatically heated as it is being used. Because the Aqua-Hot does notstore any hot water, simply open any hot water faucet and a continuoussupply of domestic hot water will be present within a few seconds. Thishot water feature is continuous and is accomplished by the Aqua-Hot’sDomestic Hot Water Heating System. Please note that the Dieselswitch must be ON to get an unlimited supply of hot water (i.e., duringshowers).

3.3 Using the Engine Preheat System

When the Aqua-Hot is at operating temperature and the Diesel-Burnerand/or the Electric Heating Element(s) switch(s) is ON, follow thesesimple instructions:A. Turn the Aqua-Hot's Engine Preheat switch ON; reference Figure 3.

This procedure will activate the Engine Preheat Circulation Pump andcirculate the engine's coolant through the Engine Preheat System.This feature will adequately warm the engine for easy start-ups oncool mornings.

NOTE: Allow approximately 1 to 2 hours of engine preheating runtime. Preheat duration will be shortest when the Diesel switch is ON.

Hot Water

EnginePreheat

SECTION 3: OPERATING INSTRUCTIONS

Aqua-Hot Hydronic Heating System Owner’s Manual 07/04® Page 6

SECTION 3: OPERATING INSTRUCTIONS

Diesel-BurnerComponentOverview

1. Control Unit 6. Fuel Solenoid 11. Combustion Chamber2. Motor 7. Electrode Holder 12. Exhaust Port3. Ignition Coil 8. Ignition Electrodes 13. Flame Sensor4. Clutch 9. Fuel Nozzle 14. Fuel Pump5. Combustion Air Blower 10. Heat Exchanger 15. Fuel Ports (Supply / Return)

16. Combustion Air Intake Port,with Adjustable Shutter

Figure 4

3.4 Diesel-Burner Component Overview

SECTION 3: OPERATING INSTRUCTIONS

B. Turn OFF the Aqua-Hot's Engine Preheat switch whenever enginepreheating is not desired.

NOTE: The Aqua-Hot's Engine Preheating System acts as a supple-mental heating source in addition to the Diesel-Burner and the ElectricHeating Element(s). While traveling, the engine's heated coolant willautomatically pass through the Engine Preheat / Motoraide System,transferring heat into the Aqua-Hot's Boiler Tank. This design featurereduces the total operating hours of the Diesel-Burner and the ElectricHeating Element(s).

EnginePreheat,continued

Figure 3

Diesel Electric EnginePreheat

������������������

IndicatorLight

Diesel ElectricEnginePreheat

������������������

Low

High

IndicatorLight

AHE-100-04S Model AHE-130-04X Model

SECTION 3: OPERATING INSTRUCTIONS

Aqua-Hot Hydronic Heating System Owner’s Manual 07/04® Page 7

SECTION 3: OPERATING INSTRUCTIONS

Diesel-BurnerOperationalFlow-Chart

NOTE:If the Aqua-Hot’s coolant

temperature is approximately 190 (+/- 5)

degrees Fahrenheit, or higher, the Motor (#2)will not operate. Only

when the coolant temperature has

dropped below 160 (+/- 5) degrees

Fahrenheit, and the VDC/ VAC Control

Thermostat is calling for heat, will the Motor (#2)

begin to operate.

Operation sequence once the Aqua-Hot’s Dieselswitch is turned ON.

NOTE:The Diesel switch’s Indicator Light will illuminate (reference Figure 3), while the Heating Status and

Diesel-Burner Status lights illuminate on the Electronic Controller,

reference Figure 6.

The Motor (#2), which turns the CombustionAir Blower (#5) and

drives the Fuel Pump(#14), will begin to

operate.

After approximately 10 - 25 seconds, the Fuel

Solenoid (#6) opens and fuel is sprayed into the Combustion Chamber (#11) through the Fuel

Nozzle (#9).

Once the ignited air-fuel mixture (FLAME) is

observed by the FlameSensor (#13), the IgnitionCoil (#3) will automatically

switch OFF. The combustion process now

continues to operate unassisted.

Simultaneously the Ignition Coil (#3)

produces a high voltage spark across the IgnitionElectrodes (#8), which

ignites the incoming air-fuel mixture.

3.5 Diesel-Burner Operational Flow-ChartReference Figure 3 for all numbers indicated inside parentheses. (e.g., #8).

SECTION 3: OPERATING INSTRUCTIONS

The combustion process will continue to operate in this

manner until one of the followingoccurs:

A.) The VDC / VAC Control Thermostat, which senses

coolant temperature, reaches the preset temperature of

approximately 190 (+/- 5) degrees Fahrenheit.

NOTE:If process "A" occurs, the

Heating Status and Diesel-Burner Status lights on the

Electronic Controller will go OFF, reference Figure 6.

B.) The Aqua-Hot’s Diesel switch is turned OFF.

NOTE:If process "B" occurs, the Dieselswitch’s Indicator Light, on the Switch Panel (reference Figure

3), will go OFF along with the Heating Status and Diesel-Burner Status lights on the

Electronic Controller, reference Figure 6.

SUMMARY:The Aqua-Hot’s Diesel-Burner is in stand-by

mode anytime the operator moves the Diesel switch (reference Figure 3) to the ON position. The Diesel-

Burner will then automatically ignite and

maintain the coolant temperature in the Aqua-Hot’s Boiler Tank without additional involvement

from the operator.

1.) The Motor (#2) will shut-off once the three (3) minute purge-cycle has

expired.-THEN-

2.) The Aqua-Hot’s Diesel-Burner will automatically turn back ON once the

coolant temperaturereaches the preset

temperature of approximately 160 (+/- 5)

degrees Fahrenheit.

The Motor (#2) will continue to run for

approximately three (3) additional minutes. This process is referred to as the purge-cycle, which cools down the heater’s

internal components and purges the

Combustion Chamber (#11) of any residual

exhaust gases.

Once the heater switches OFF, thermostatically or

manually, the FuelSolenoid (#6) closes,

which interrupts the supply of diesel fuel to the Fuel

Nozzle (#9).

NOTE:When the Aqua-Hot’s

Diesel-Burner is switched OFF, by the VDC / VAC

Control Thermostat, the following process will take

place:

3.5 Diesel-Burner Operational Flow-Chart, continuedDiesel-BurnerOperationalFlow-Chart,continued

SECTION 3: OPERATING INSTRUCTIONS

Aqua-Hot Hydronic Heating System Owner’s Manual 07/04® Page 8

SECTION 3: OPERATING INSTRUCTIONS

ImportantInformation

3.6 Precautions

WARNINGS:• The Aqua-Hot's Exhaust is HOT!• DO NOT park in areas where dry conditions exist underneath the

vehicle, as a fire may result (e.g., in a dry grassy field).• DO NOT operate the Aqua-Hot’s Diesel-Fired Burner inside an

enclosed building.• The Heater should be switched OFF when refueling.

CAUTION: DO NOT operate the Diesel-Burner and/or the ElectricHeating Element(s) without the water and antifreeze solution in the Aqua-Hot’s Boiler Tank. Failure to do so will cause serious damage to theHeater.

SECTION 4: MAINTENANCE

Upkeep 4.1 Maintenance ScheduleMonthly

Check the Aqua-Hot's solution of water and antifreeze to ensure that it isat the proper level. Do this by visually checking the coolant level in theAqua-Hot's Expansion Tank; reference Figure 1. Please note that thecoolant level should be checked only when the Aqua-Hot is at maximumoperating temperature (i.e., when the Diesel-Burner cycles OFF),“HOT.”

WARNING: When the Aqua-Hot is at maximum operating temperature(HOT), DO NOT loosen the Radiator Cap. If removed, scalding by hotvapor or coolant could result.

NOTE: This Aqua-Hot product utilizes a Propylene Glycol (P.G.) basedwater and antifreeze solution. This P.G. based solution is a Boiler typeantifreeze, which is Generally Recognized as Safe (“GRAS”) by the FDA.For additional information regarding this GRAS antifreeze product, pleasecontact us at 1-800-685-4298 or visit our website atwww.vehiclesys.com.

If the coolant needs replenishing, fill the Aqua-Hot’s Expansion Tank to theFULL HOT level mark. Be sure to use a 50/50 mixture of water and (P.G.)antifreeze.

SECTION 4: MAINTENANCE

Aqua-Hot Hydronic Heating System Owner’s Manual 07/04® Page 9

SECTION 4: MAINTENANCEAnnually

WARNING: Before cleaning or servicing, disconnect all power supplies.

To keep your Aqua-Hot running smoothly, it is ideal to have the Diesel-Burnertuned-up annually. A tune-up should consist of a new Fuel Nozzle and FuelFilter, along with a thorough cleaning of the Combustion Chamber, ifnecessary (reference Figure 5). To ensure maximum Diesel-Burnerperformance, always use the recommended Fuel Nozzle (i.e., 0.35 GPH) andFuel Filter (i.e., 10 Micron) when replacing these parts. Reference the Aqua-Hot “Parts Manual” for spare parts information. If detailed replacementinstructions are needed, please reference the Aqua-Hot “Shop Manual” orcontact the Technical Support Department at 1-800-685-4298 for the nearestAqua-Hot Service Center.

CAUTION: DO NOT operate the Diesel-Burner and/or the Electric HeatingElement(s) without the water and antifreeze solution in the Aqua-Hot’s BoilerTank. Failure to do so will cause serious damage to the Heater.

Upkeep,continued

Fuel Nozzle(0.35 GPH)

CombustionChamber

Fuel Filter(10 Micron)Figure 5

SECTION 5: WINTERIZATION

5.1 Domestic Hot Water System

The Aqua-Hot's Domestic Hot Water Heating System must be completelydrained of domestic water any time the heater is stored where freezingtemperatures may be experienced.

CAUTION: Not winterizing your Aqua-Hot when freezing temperaturesare present will result in serious damage to the Aqua-Hot's DomesticHot Water Heating System.

NOTE: The Aqua-Hot can still be used for interior zone heating even if thedomestic hot water system has been drained and winterized.

Please follow the instructions listed below when winterizing the Aqua-Hot’sDomestic Hot Water Heating System:

A. Completely drain the fresh water storage tank.

NOTE: If your motorhome is equipped with appliances that use freshwater (e.g., ice makers, water purifiers, etc.) follow the manufacturer'srecommendation for winterization.

B. Disconnect the domestic water demand pump's suction line from thefresh water storage tank.

Storage

SECTION 5: WINTERIZATION

Aqua-Hot Hydronic Heating System Owner’s Manual 07/04® Page 10

SECTION 5: WINTERIZATIONC. Attach an adequate piece of hose onto the suction side of the domestic

water demand pump.

D. Place the opposite end of the hose into an adequate supply of FDAapproved RV-Antifreeze.

E. Open / close all interior and exterior water faucets, one at a time, untilonly pure RV-Antifreeze is present. Perform this procedure for both thehot and cold faucets.

F. Remove the hose and reconnect the domestic water demand pump'ssuction line to the fresh water storage tank.

G. Disconnect all electrical power supplies to the Aqua-Hot during storage.

NOTE: For de-winterization, completely fill the fresh water storage tank.Open / close all interior and exterior water faucets, one at a time, until onlyclear water is present / visible.

CAUTION: If you are disinfecting your potable water system after de-winterizing, be sure to follow RVIA’s “Instruction for Disinfection ofPotable Water Systems on Recreation Vehicles.” These instructionscan be found in the ANSI A119.2 Handbook for Recreational Vehicle Stan-dards. To receive a copy of this RVIA Standard, write to: RecreationVehicle Industry Association, 1896 Preston White Drive, P.O. Box2999, Reston, VA 20195-0999 or visit the RVIA website at www.rvia.com.

Storage,continued

SECTION 6: TROUBLESHOOTING6.1 General Information

If the Aqua-Hot’s Diesel switch “Indicator Light” does not illuminate, and theDiesel-Burner is not functioning, locate the Electronic Controller (Figure 6)and check the following:A. Check the Aqua-Hot’s Electronic Controller for any RED lights indicating a

fault condition. Reference Figure 6 and the Electronic Controller Trouble-shooting section to identify these fault conditions.

B. Check for loose wire connections on the Electronic Controller’s TerminalStrips/Plugs. When checking for loose Terminal Strips/Plugs, remove theElectronic Controller Faceplate by unscrewing the four cover screws.

C. Remove the Aqua-Hot’s Access Cover and check for loose plug connec-tors on the Diesel-Burner's Control Unit (located on the under side); reference Figure 1..

D. Check to ensure that the vehicle’s fuel tank has a sufficient level of fuel.

E. If your Aqua-Hot still fails to operate, please contact the Technical Sup-port Department at 1-800-685-4298 for additional troubleshooting assis-tance or visit our website at www.vehiclesys.com.

GeneralInformation

SECTION 6: TROUBLESHOOTING

Aqua-Hot Hydronic Heating System Owner’s Manual 07/04® Page 11

SECTION 6: TROUBLESHOOTING6.2 Electronic Controller Diagnostic

#5

#4

#3

#2

#1

Electric HeatingElement Status

Low Voltage

Reset

Low Tank-LevelCutoff

Heating Status

Engine PreHeatPump

Low BatteryVoltage Fault

Low TempCutoff Status

Overload Fault

Pump #2

Pump #1

Pump #3

Diesel-BurnerStatus

Heating ZonesStatus

ELECTRONIC CONTROLLER

���������R

ElectronicController

Figure 6

SECTION 6: TROUBLESHOOTING

ElectronicController,continued

Low Tank-Level Cutoff Indicator Light:This indicator light will illuminate RED when either the Electric HeatingElement(s) and/or Diesel-Burner have automatically shut down due to a lowwater and antifreeze solution level inside the Aqua-Hot’s Boiler Tank. This faultwill automatically reset when the low level condition is corrected.

Low Battery Voltage Fault Indicator Light:This indicator light will illuminate RED whenever the VDC voltage level is toolow for the Aqua-Hot to operate properly. This fault must be manually resetafter the voltage level has been restored to the VDC battery system, referenceLow Voltage Reset below.

Low Voltage Reset (Button):The Aqua-Hot’s Electronic Controller must be manually reset whenever theLow Battery Voltage Fault indicator light has been activated. To reset theElectronic Controller, simply depress the “Low Voltage Reset” button locatedon the Electronic Controller (use a thin, straight object to access the resetbutton through the small hole in the Faceplate).

Overload Fault Indicator Light:This indicator light will illuminate RED whenever one of the following conditionshave occurred:1. The Aqua-Hot is off due to an electrical overload (i.e., short) in the main

VDC power supply circuitry.2. The Aqua-Hot is off due to a combination of high electrical VDC power

loads and a high surface temperature of the Electronic Controller.

SECTION 6: TROUBLESHOOTING

Aqua-Hot Hydronic Heating System Owner’s Manual 07/04® Page 12

SECTION 6: TROUBLESHOOTINGThe Aqua-Hot will automatically restart once the electrical overload (i.e., short)and/or high heat condition is corrected.

Heating Zones Status Indicator Lights:These five indicator lights (separately) will illuminate GREEN whenever aZone Thermostat, for each particular zone, is calling for heat. The GREENindicator lights also indicate that VDC power is being supplied to the particularinterior heating zone’s Heat Exchangers (i.e., fan motors). If any of the fiveindicator lights illuminate RED, it indicates that an electrical overload condition(i.e., short) has occurred in a particular heating zone’s circuitry.

NOTE: A short in either a heating zone’s Interior Room Thermostat orheating zone’s Heat Exchanger circuit will cause the indicator light toilluminate RED.

Pumps #1, #2, and #3 Indicator Lights:These indicator lights (separately) will illuminate GREEN whenever aCirculation Pump is operating. If any of the three indicator lights illuminateRED, it indicates that an electrical overload condition (i.e., short) has occurredin the particular component’s circuitry.

NOTE: The Zone Circulation Pumps (separately) are activated whenevera Zone Thermostat calls for heat.

Engine Preheat Pump Indicator Light:This indicator light will illuminate GREEN whenever the Engine Preheat Pump

ElectronicController,continued

SECTION 6: TROUBLESHOOTINGis operating. Please note that this light will only be active if the Engine Preheatswitch is ON in conjunction with either the Diesel and/or the Electric switch. Ifthis indicator light illuminates RED, it indicates an electrical overload condition(i.e., short) has occurred in this particular component’s circuitry.

Heating Status Indicator Light:This indicator light will illuminate GREEN whenever the Aqua-Hot’s VDC / VACControl Thermostat is calling for heat, allowing the water and antifreezesolution in the Aqua-Hot’s Boiler Tank to be heated by either the Diesel-Burnerand/or the Electric Heating Element(s). When this indicator light is off, noheat is being supplied to the Aqua-Hot’s Boiler Tank.

NOTE: The Aqua-Hot’s VDC / VAC Control Thermostat will automaticallyactivate the Diesel-Burner and/or the Electric Heating Element(s), only ifthe Diesel and/or Electric switch is in the ON position. In order to heat yourmotorhome / domestic hot water, simply choose the desired heatsource(s) and leave the switch(s) (i.e., Diesel and/or Electric)ON.

Electric Heating Element Status Indicator Light:This indicator light will illuminate GREEN whenever the Aqua-Hot’s ElectricHeating Element(s) is operating and providing heat to the Aqua-Hot’s BoilerTank. Please note that this light will only be active if the Electric switch is inthe ON position. If this indicator light illuminates RED, it indicates an electricaloverload condition (i.e., short) has occurred in the Electric Heating Element’sVDC powered circuitry.

ElectronicController,continued

SECTION 6: TROUBLESHOOTING

Aqua-Hot Hydronic Heating System Owner’s Manual 07/04®

WARRANTY INFORMATION

Vehicle Systems, Inc. warrants the AQUA-HOT Heater to be free from defects in material and work-manship under normal use and service for a period of two (2) years on both parts and labor com-mencing upon the original date of registration of the vehicle. The warranty period may not however,exceed 36 months from the orignal date of delivery by Vehicle Systems, Inc. Replacement parts arewarranted for the remainder of the Heater's standard warranty period or for six months (180 days),whichever is greater.

This warranty is conditional upon proper use of the Heater by the end-user. This warrantydoes not apply to damage or failure of the AQUA-HOT Heater, or the vehicle into which itwas installed, due to improper installation, assembly, maintenance, abuse, neglect, acci-dent, or the use of parts not supplied by Vehicle Systems, Inc. Vehicle Systems is not re-sponsible for incidental or consequential damages.

The intent of this warranty is to protect the end-user of the heating system from such defects, whichwould occur in the manufacture of the product. The warranty is not intended to protect the end-userfrom problems, which are outside the ability of Vehicle Systems’ control.

To obtain warranty repair authorization or for additional product information, please contact theTechnical Support Department at 1-800-685-4298 (8 AM to 5 PM Mountain Standard Time).

- FOR AQUA-HOT MODELS -

Aqua-Hot Hydronic Heating System Owner’s Manual 07/04®

Date Service Performed Service Center

OWNER’S SERVICE LOG:

Date Service Performed Service Center

OWNER’S SERVICE LOG: (Continued)

Aqua-Hot Hydronic Heating System Owner’s Manual 07/04®

-MEMO-

-MEMO-

Aqua-Hot Hydronic Heating System Owner’s Manual 07/04®

Aqua-Hot™ Motor Coach Heating System Owner's Manual 08/03

������ �������������� ����������� ��������������� ���������������15549 East Highway 52 · Fort Lupton, Colorado 80621 · 1-800-685-4298 · Fax: 303-857-9000

����� Copyright 2003 Vehicle Systems, Inc. All rights reserved

www.vehiclesys.comLTE-LMA-302