S iriux h o m e 60 S i riux home 40 4 2,5 0 0,5 6 4 Hm Qm 3 /h For the accelerated circulation of hot water in heating circuits with duty point optimisa- tion for: New or old systems (reconditioning – extension) Systems with or without thermostatically controlled valves Single-family houses Radiators and underfloor heating systems Thermosiphon-type systems OPERATING RANGE Flow rate of up to 4 m 3 /h Manometric head of up to 6 m Max. operating pressure 10 bar Min. intake pressure 0,3 bar at 95°C Water temperature range +2 at +110°C * EEI-Part 2 ≤0,20 * for a max. ambient temperature of 40°C The reference criterion for the most efficient circulating pumps is EEI ≤ 0.20 APPLICATIONS BENEFITS ENERGY SAVINGS Circulating pump conforms to the ErP 2013 and 2015 European directive. Min. consumption: 3 Watt. Current and cumulative display of electri- city consumption of the circulating pump. "Fine pilot" function for dynamic optimisa- tion of the setpoint value. • VERSATILITY Precise setting of differential pressure (TDH - Total Dynamic Head) for optimal energy savings. 2 regulation modes meet the needs of all types of systems. Ventilating function. Night mode. Automatic degumming. COMFORT Eliminates whistling and noise around thermostatically controlled valves. Automatically adapts its speed to the needs of the heating system. INSTALLATION AND ADJUSTMENT Simple and intuitive setting interface. Salmson tool-free connector. Compact size . • Salmson connector • Siriux Home available in 180 mm and 130 mm port-to-port distances High-efficiency circulating pumps Heating 50 Hz N.T. N o 111-3/ENG - Éd.5/06-14 SIRIUX HOME 1

APPLICATIONS - Salmson€¦ · Heating system Regulation mode Size of system Siriux home With thermostatically controlled valves Up to 15 radiators Siriux home 40 Up to 20 radiators

Embed Size (px)

Citation preview

Siriux home 60Siriux home 40

42,50

0,5

6

4

Hm

Qm3/h

For the accelerated circulation of hot water in heating circuits with duty point optimisa-tion for:• New or old systems (reconditioning – extension)

• Systems with or without thermostatically controlled valves

• Single-family houses• Radiators and underfloor heating systems• Thermosiphon-type systems

OPERATING RANGEFlow rate of up to 4 m3/hManometric head of up to 6 mMax. operating pressure 10 barMin. intake pressure 0,3 bar at 95°CWater temperature range +2 at +110°C*

EEI-Part 2 ≤0,20* for a max. ambient temperature of 40°C

The reference criterion for the most efficient circulating pumps is EEI ≤ 0.20

APPLICATIONS

BENEFITS• ENERGY SAVINGS Circulating pump conforms to the ErP 2013 and 2015 European directive. Min. consumption: 3 Watt. Current and cumulative display of electri-city consumption of the circulating pump. "Fine pilot" function for dynamic optimisa-tion of the setpoint value.

• VERSATILITY Precise setting of differential pressure (TDH - Total Dynamic Head) for optimal energy savings. 2 regulation modes meet the needs of all types of systems. Ventilating function. Night mode. Automatic degumming.

• COMFORT Eliminates whistling and noise around thermostatically control led valves. Automatically adapts its speed to the needs of the heating system.

• INSTALLATION AND ADJUSTMENT Simple and intuitive setting interface. Salmson tool-free connector. Compact size .

• Salmson connector

• Siriux Home available in 180 mm and 130 mm port-to-port distances

High-efficiency circulating pumps Heating

50 Hz

N.T. No 111-3/ENG - Éd.5/06-14

SIRIUX HOME

1

DESIGN• Hydraulic part- Single housing with threaded ports for direct fitting onto pipework.

• Motor- Single-phase, wet runner, with bearings lubricated by pump fluid.

- Self-regulating, adapts to the pressure requi-red by the system.

- Self-protected: requires no external protection.

- Synchronous motor with ECM (Electronically Commuted Motor) technology, equipped with a permanent magnet rotor. The magne-tic field rotating around the stator is created by the electronic commutation of the coils. This rotating field creates a continuous torque due to the attraction of the opposing magnetic poles of the rotor, by controlling its position (synchronous motor). This ensures optimal motor performance, regardless of its speed.

Protection class: IPX4DMax. temperature of the fluid conveyed: TF 110ECM conformity: - 61000-6-1 - 61000-6-2 - 61000-6-3 - 61000-6-4

IDENTIFICATION

Siriux home 4 0 - 25 / 180

High-efficiency pump Residential application

TDH at 0 m3/h

DN (nominal diameter) of ports:

Port-to-port distance of pump housing

BASIC CONSTRUCTIONMain parts MaterialPump housing Cast ironImpeller Mat. CompositeShaft-air gap sleeve Stainless steelSuction ring Stainless Stainless steelBearings GraphiteSeal Ethylene-propylene

BENEFITS• Energy savings: - High-efficiency circulating pumps, with duty point optimisation.

- Energy savings of up to 90% compared to a traditional circulating pump.

- Conforms to European Directive: ErP 2013 and ErP 2015.

• Noise control - Eliminates whistling and hydraulic noise around thermostatically controlled valves.

- The circulating pump's characteristics are au-tomatically adjusted according to the opening and closing of the thermostatically controlled valves.

• Simple and intuitive settings

• Communication interface- Facilitates settings thanks to its intuitive icons

- Allows for the visualisation of all settings made at a glance

- Makes users aware of energy savings.

• Salmson connector

- Quick and tool-free electrical connections.

- Clear separation of hydraulic and electri-cal connections for improved safety.

- Turn to select an icon or adjust a parameter.

- Press to select a menu or confirm a setting.

SIRIUX HOME

2

pilotpilot pilotpilot

AutoH

Q

Auto

SETTINGS

Electricity consumption • Cumulative electricity consumption of Siriux Home since first use

• Current electrical consumption of Siriux Home

Manometric head setting2 available sizes of motor:

• Siriux home 40-** - TDH: 0.5 m to 4m

• Siriux home 60-** - TDH: 0.5m to 6m

Regulation function:

Venting function:

Fine pilot function:

Automatic slower night mode:

With this regulation mode, in the event of a drop in flow rate, the differential pres-sure (manometric head) is reduced electronically, according to the preset differen-tial pressure setpoint value.

Recommended regulation mode for heating installations with thermostatically controlled valves

With this regulation mode, the electronic system keeps the differential pressure of the circulating pump at a constant level regardless of the flow rate, according to the preset pressure setpoint value.

Recommended for underfloor heating systems and Thermosiphon-type systems.

First purpose: When used for the first time, this function allows for the expulsion of air bubbles from the Siriux Home rotor chamber. Secondary purpose: This function also supports the venting of the heating system. When operating, it releases air bubbles trapped within the system and conveys them to the highest point in the system (deaerator).

The "venting" function operates for 10 minutes. A countdown is displayed in the upper, right-hand side of the screen. At the end of this ten-minute period, the pump automatically returns to the settings selected previously.

When the Fine Pilot function is activated, the pump analyses the heat requirement on the basis of the setpoint value. This analysis allows for the continuous adjustment of the value within the partial load range. The pump power is thus continuously optimised.

The Fine Pilot function can only be activated via a ∆p-v regulation mode.

Function activated

Function not activated

Thanks to its temperature sensor, Siriux Home can detect when the boiler is operating in "night" mode.When Siriux Home detects a significant drop in water temperature, it automatically swit-ches over to its "night" curve to avoid any unnecessary power consumption.

As soon as it detects a temperature rise, Siriux Home switches back to its preset operating curve.

Function activated Function not activated

Function activated Function not activated

SIRIUX HOME

3

0 1 2 3 4

0 4 8 12

0

1

2

3

4

5

6

16

max.

∆p-v

min.

0

20

40

0 1 2 3 4min.

5m 4m 3m 2m

max.

Q imp.gpm

Q m³/h

Q m³/h

Hm

P1

Q l/sQ l/min

Siriux home 60

100

0

20 30

0,4 0,6 0,80,2 1 1,2

40 50 60 70

0 1 2 3 4 5 Rp ½

Rp 1¼0 0,2 0,4 0,6 0,8 1,0 1,2

0 0,4 0,8 1,2 1,6 Rp 1m/s

Siriux home 4015/1-4, 25/1-4, 30/1-41~230 V - Rp ½, Rp 1, Rp 1¼

0

0,5

1,0

1,5

2,0

2,5

3,0

3,5

4,0

0

10

20

P1/W

Hm

max.

∆p-v

min.

min.

max.

0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 Qm³/h

0 0,2 0,4 0,6 0,8 1,0 Ql/s

0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 Qm³/h3m 2m 1m

0 1 2 3 4 5 Rp ½

Siriux home 4015/1-4, 25/1-4, 30/1-41~230 V - Rp ½, Rp 1, Rp 1¼

max.

∆p-c

min.

min.

max.

Rp 1¼0 0,2 0,4 0,6 0,8 1,0 1,2

0 0,4 0,8 1,2 1,6 Rp 1m/s

0

0,5

1,0

1,5

2,0

2,5

3,0

3,5

4,0

0

10

20

P1 W

Hm

0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 Qm³/h

0 0,2 0,4 0,6 0,8 1,0 Ql/s

0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 Qm³/h

0,5m2m 1m3,5m 3m

Q m³/h

Hm

P1

Q imp.gpm

Q m³/h

Q l/sQ l/min

0 1 2 3 4

0 4 8 12

0

1

2

3

4

5

6

16

max.

∆p-c

min.

0

20

40

0 1 2 3 4

min.

4m3m

2m1m

max.

Siriux home 60

100

0

20 30

0,4 0,6 0,80,2 1 1,2

40 50 60 70

HYDRAULIC PERFORMANCE

Heating system Regulation mode Size of system Siriux home

With thermostatically controlled valvesUp to 15 radiators Siriux home 40

Up to 20 radiators Siriux home 60

Underfloor heatingUp to 120 m² Siriux home 40

Up to 220 m² Siriux home 60

Thermosiphon-type - Siriux home 40

QUICK SETTING HELPValues given for information only

SIRIUX HOME

4

PE N L

1

4 5 61

2

2 3

3

PE N L

1

4 5 61

2

2 3

3

PE N L

1

4 5 61

2

2 3

3

PE N L

1

4 5 61

2

2 3

3

PE N L

1

4 5 61

2

2 3

3

Siriux home 40

Siriux home 40

Siriux home 60

Siriux home 60

Length of most unfavourable loop (outbound & inbound) Setpoint value

30 m 1,3 1,3 1,0 1,0 1,2 1,140 m 1,5 1,3 1,3 1,0 1,4 1,350 m 1,8 1,5 1,5 1,3 1,8 1,760 m 2,3 2,0 1,8 2,2 2,0 1,880 m 2,5 2,3 2,9 2,6 2,4100 m 2,8 2,5 3,2 3,0 2,8120 m 3,0 4,0 3,5 3,2

Flow rate (m3/h) 0,5 1 1,5 2 2,5 3

Siriux Master

Outbound & inbound length of

PER 16 x 20Setpoint value

20 m 1,0 1,040 m 2,0 2,0 60 m 3,0 3,080 m 4,0100 m 5,0

Flow rate (m3/h) 0,5 1 1,5 2 2,5 3 3,5

Siriux Master

Outbound & inbound length of

PER 13 x 16Setpoint value

20 m 1 1,540 m 3,0 3,060 m 4,5 80 m 100 m

Flow rate (m3/h) 0,5 1 1,5 2 2,5 3 3,5

Siriux Master

QUICK SETTING HELP

INSTALLATION POSITIONS

ELECTRICAL CONNECTIONSQuick and tool-free electrical connections

For systems with underfloor heating

For systems with radiators

NB : These setpoint values are given for information only. The flow rate can be adjusted as follows:Lowest setpoint value = reduced flow rateHighest setpoint value = increased flow rate, within the circulating pump's performance limits

SIRIUX HOME

5

Order referenceThreaded tube connection

1/2" 3/4" 1" 1"1/4 2"

Siriux home 40-25 / 180 mm _ RED 2027 RU 2634 _ _

Siriux home 40-32 / 180 mm _ _ RED 2634 RU 3342 RU 4049

Siriux home 40-15 / 130mm RU 1521 _ _ _ _

Siriux home 40-25 / 130mm RED 2027 RU 2634 _ _

Siriux home 60-25 / 180 mm _ RED 2027 RU 2634 _ _

Siriux home 60-32 / 180 mm _ _ RED 2634 RU 3342 RU 4049

Siriux home 60-15 / 130mm RU 1521 _ _ _ _

Siriux home 60-25 / 130mm _ RED 2027 RU 2634 _ _

139

34K

ØG

139

34K

ØG39 41

81

H

39 41

81

H

Order reference

Motor Pump

P1 (W) I(A) Speed (rpm) H

(mm)K

(mm) Ø G Weight (kg)Min Max Min Max Min Max

Siriux home 40-25 / 180 mm

3W 20W 0,04 0,26 1 200 3 600180 90 1"1/2

2,3Siriux home 40-32 / 180 mm 2"Siriux home 40-15 / 130mm 130 65 1"Siriux home 40-25 / 130mm 1"1/2Siriux home 60-25 / 180 mm

3W 40W 0,04 0,44 1 200 4 700180 90 1"1/2

2,3Siriux home 60-32 / 180 mm 2"Siriux home 60-15 / 130mm 130 65 1"Siriux home 60-25 / 130mm 1"1/2

ELECTRICAL AND DIMENSIONAL SPECIFICATIONS FEATURESa) Electrical- 230 V - 50 Hz (60Hz) single-phase- Motor protection via circuit-breaker is not essential.

b) Fitting- Axis of motor always horizontal.- Connection to system via pipe unions.

c) Packaging- Supplied with connector and gaskets, but without pipe unions.

d) Maintenance- Standard replacement of the appliance.

• Shut-off ball valve RU 2634 - Ref.: 4104734

• Pipe union

ACCESSORIES

• Adapter rings ØG 1”1/2 - 2” Ref.: 4051850

• Insulation housing Ref.: 4160237

• 2 m cable with lateral connector (set of 10 units) Réf.: 4164854

SIRIUX HOME