PCXCW14
Products manufactured in an ISO certified facility.This document contains the most current product information as of this printing.
@2014-06
Chilled Water SystemSolution Product Catalogue
PRODUCT SYSTEMAir-Cooled
Air Cooled Mini Chiller
Fan Coil Unit
Application
Solution
Cooling & Heating Capacity
R22UAE
R407CUAP
FWE-E
FWC-C
FUD-B
4.0 6.0 8.0 10.0
kW
20.0 25.0 30.0 40.0
Products OverviewContents
01
Application
04
Air Cooled Mini Chiller
13
Solution
Fan Coil Units
Wall Mounted
19
Remark: All unit photos in this catalog are solely for illustration purpose, actual outlook may differ slightly. All specifications are subjected to change by the manufacturer without prior notice.
15.0 50.0
025/030/040/050/060/080/100/120/150
060/080/100/120/150
020/025/030/040/050/055
020/025/030/040/050/055
R410AUAQ
Ceiling Cassette Compact Type (600 x 600)
Ceiling Cassette Type (900 x 900)
Ceiling Cassette Type (900 x 900) With Brushless DC Motor
Ceiling Convertible Type
Ceiling Concealed Type Ducted Blower Type
20 21 22 24
25 27
020/025/030/040/050/060/080/100/120/150
020/025/030/040/050/060/080/100/120/150
Application
AIR COOLED MINI CHILLER APPLICATION EXAMPLES :
CHILLED WATER SYSTEM SOLUTION ADVANTAGES :
Chilled Water System Solution
Advantages
Long Piping Application
Quiet Operation
Less RefrigerantHandling
No Necessity To Use Cooling Towers
Versatility InSystem Coupling
Simple On SiteInstallation
LONG PIPING APPLICATION
Daikin chilled water system has no limitation in piping lengths unlike direct expansion refrigerant system. As long as the water pump head pressure is sufficient to pump the water through the water pipe network, the chiller can be installed far away from the fan coil units. Daikin Mini Chiller is designed to support water operating pressure up to 1000kPa. With such high design pressure, Daikin mini chiller is capable of fulfiling In the case where the Mini Chiller's built in pump head is insufficient to support the overall friction loss, additional pump can be installed to cater for higher pump head requirement.
Private Houses
Hotels
Gym Centres
@Office Rooms Coffee Houses
Restaurant
Universities & Halls
Availablility of cooling only & heatpump
models
Centralized ControlNetwork supports up
to 50 chillers and 120 FCU
Multiple tempratureZone Control
Operation can be managedaccording to zones for different comfort need
Serviceability & ErrorCode Troubleshooting
Easy access for servicing all components. Error codedisplayed on control panel
for troubleshooting purpose
Energy Saving Programmable Timer
Customizable operationschedule of chiller and FCU
based on requirement topromote energy saving
Master/Slave OptionControl based on
network grouping orapplication
Dry Contact BMSCompatibility
Abiblity to be integratedwith BMS
1 2
QUIET OPERATION
Quiet operation due to fan coil unitsand chiller can be placed far away from room
Daikin mini chiller is designed for air cooled application where is no necessity to use the cooling tower especially for small and medium size of chilled water application
NO NECESSITY TO USE COOLING TOWERS
› Less Refrigerant Handling› No Refrigerant Used In Occupied Space› Water As Cooling Medium
Refrigerant is only circulating within the mini chillerunit. Meanwhile, water acts as the cooling medium for FCU. When there is less refrigerant used, the scope of care on refrigerant handling is smaller. In case when there is a leak water is definitely easier to handle in term of process and cost.
LESS REFRIGERANT HANDLING
VERSATILITY IN SYSTEM COUPLING
Chilled water system is designed with versatility in system coupling where there is no limitation in the number of fan coil unit coupling with mini chiller as long as they meetthe designed capacity requirament & water flow rate. System coupling of one to one and one to many configurations
ONE TO ONE
ONE TO MANY
SIMPLE ON SITE INSTALLATION
Refrigarent
The Daikin mini chiller is fully assembled, completewith all necessary components in one unit like waterpump, internal wiring, fully charged with refrigerantand undergo strict testing and quality check before delivery. Only connection to water piping and power supply is required at site.
EASY INSTALLATION AND MAINTENANCE :
FACTORY PRECHARGED REFRIGERANT
Each heat exchanger in the chiller is brazed and tested against leakages through dried air at 30 bars. After that, another process of system vacuuming is done before it is accurately charged with refrigerant to ensure optimum performance. Thus, it saves the hustles of field charging by installers.
Brazed Plate Heat ExchangerPlate type heat exchanger has acompact structure and a high levelof heat exchange efficiency
FILTER DRIER Remove dirt and moisture in the refrigerant circuit.
MULTISTAGE END SUCTION WATER PUMPImpeller and all movable parts in contact with the water are made of stainless steels.
Diaphragm Expansion TankPrevent damage of hydraulic components and cracking of piping due to expansion of hot water in the pipes.
WATER STORAGE TANK Prevent the compressor from switching ON/OFF too frequently during low load conditions such as night time.NOTE: Model UA(E/P)080~150C/CR water tank is offered as an optional device.
SERVICEABILITY & ERROR CODE FOR EASE OF TROUBLESHOOTING
By opening the front panel, one can access and service all the components in the chiller. The chiller is equipped with self diagnosis function which allow the chiller panel to display total of 19 type of faulty occurred in the system by showing different error code on the LCD screen of the panel.
Air Cooled Mini Chiller
Mini chiller can be installed far away from fan coil units
INTEGRATED HYDRONIC COMPONENTSDaikin Mini Chiller is fully integrated and equipped with key hydronic components such as expansion tank, water tank, brazed plate heat exchanger and water circulating pump. As all hydronic components are assembled and tested in the factory, installation of additional component on site can be eliminated.
3 4
Mini ChillerAir Cooled
PARALLEL INSTALLATIONDaikin Mini Chiller provides flexibility in adding capacity for building extension. This can be done by installing the mini chiller in parallel connection.A network of up to 50 chillers is possible to be connected in a system. For ease of controlling and setting, Daikin Mini Chiller panel implement Master and Slave function. This function allows user to monitor all the settings on the slave units at the master unit.
Supported Up To 50 Units Of Chiller
Chiller 0 Chiller 2Chiller 1
Chiller Panel 0(Master)
Chiller Panel 1(Slave)
5 way wire (CM8)ChillerCommunication Bus
SUPERIOR RELIABILITY :
SCROLL COMPRESSORScroll Compressors are used for the units to offer a quieter and more reliable performance over a wide operating temperature range. (Except UAE020C/CR which uses rotary compressor).
For UA(E/P) 030, 040, 050, 060, 080, 100, 120, 150 CR, phase protector is provided to prevent the compressor from rotating in the wrong directions.
State-Of-The-Art Components
CopelandCompliant ®
Scrolls
High EfficiencyMotor
Quiet ShutdownDevice
ANTI-FREEZE PROTECTIONThe chiller unit has several anti-freeze protection features:
1. Built-in heater in BPHEThe BPHE has a strip heater around it to prevent water freezing inside.
2. Anti-Freeze sensorBPHE can avoid the frosting as the anti-freeze sensor will send the signal to cut out the compressor if the water temperature becomes too cold.
3. Water pressure differential switchThis protection feature will ensure there is water flow in pipings when the chiller is in operation. Otherwise, the compressor will cut out immediately.
MICROPROCESSOR CONTROLDaikin chillers are equipped with microprocessor controller that will control and regulate the operation of the unit.
Besides that, the controller that contains the well developed algorithm will provide protection to the chiller by accurately sensing the key temperatures in both the water and refrigerant circuit. Should there be any abnormal reading received by controller, an alarm signal will be sent to chiller panel, followed by protection action plans such as to stop the operation of compressor, condenser fan motor or circulating water pump.
BRAZED PLATE HEAT EXCHANGER (BPHE)The heat exchanger is made of AISI 316 stainless steel plates closely arranged and brazed together to maximize possible heat exchange efficiency.
AISI 316 stainless steel BPHE
SAFETY PROTECTIONThe safety protections provided for the Daikin chiller are:• High & Low Pressure Switches • Anti-Freeze Protection Sensor• Discharge Temperature Sensor• Over Pressure Relief Valve• Water Pressure Differential Switch• Anti-Freeze Heater on BPHE• Compressor Water Pump & Fan Motor Overload Protector
EFFICIENCY AND PERFORMANCE :
CHILLER CONTROL PANELThe chiller panel controller is designed to control the chiller operation. This device allows the user to have customized control for each connected unit.
Each chiller will have a chiller control panel that comes as a standard accessory. At the same time, the chiller control panel is able to be installed remotely through the cable up to a distance of 100 meters. Example, the chiller panel can be installed in a centralized plant control room for the building.
The chiller control panel has been designed taking into consideration of the user friendly and yet versatile control features.
Features:• Whole system configuration.• Unique parameter settings.• Operation status display.• Tracing fault record (offer quick troubleshooting solutions).
• The display is shown in an 8-lines graphical LCD display. There are 8 dedicated keys available in the panel.• Menu selection.• Navigation on the screen.• Modification of the selected value.
5 6
LOAD BALANCING CONTROLFor UA(E/P)080 ~ 150 C/CR both compressors will cut in and cut out depending on their accumulative operating time. This sequencing control feature will ensure no single compressor is overload in operation as well as to ensure longer reliability of compressors.
CAPACITY STEP CONTROLUA(E/P)080 ~ 150 C/CR has been designed with two separate refrigerant circuits, i.e. it has two compressors. By doing so, the unit has part loading capabilities, i.e. 0-50-100% of rated capacity. This will improve the reliability and energy efficiency of the unit, especially during low loading operations.
ANTI CORROSION GOLD ALUMINUM FINGold Aluminum fin is offered as the standard material of the condenser heat exchanger of this series of chiller.
EFFICIENCY AND PERFORMANCE :
Air-Cooled Mini Chiller
This innovative air cooled chiller by Daikin was designed with one purpose in mind, which is to offer cost and energy saving for users.
Model: UAQ 030/040/050/055 CR
BETTER PERFORMANCE
• Usage of higher efficient R-410A rotary compressors in tandem configuration• Tight tolerances between moving parts resulting in high compressor volumetric efficiency• Minimize mechanical losses• Minimize gas flow losses and turbulence• Optimize compressor oil return
CAPACITY STEP CONTROL
3 steps compressor loading (0%-40%-60%-100%) for UAQ 040 CR & UAQ 050 CR 2 steps compressor loading (0%-50%-100%) for UAQ 030 CR & UAQ 055 CR
ELIMINATION OF WATER TANKCombining the Tandem Compressors technology with the algorithm of the microprocessor control, water tank can be eliminated in most instances.
CHOICES OF SINGLE PHASE AND 3 PHASE POWER SUPPLY CONNECTION• Usage of single phase power supply compressors and circulating water pump.• Offers flexibility to field installation.
water
Ref.1 Ref.2 Ref.1 Ref.1Ref.2
waterwater water
Chiller Panel Comes AsThe Standard Controller
Compatible With Smart Manager
PARALLEL INSTALLATIONA network up to 50 chillers in a system is possible. Control on the operation of the chillers will be done through the microprocessor controller. The external water piping connection can be made either from the left or right side of the unit.
TRUE DUAL CIRCUITS BPHEApply sophisticated technology of true dual circuit
BPHE.
The true dual BPHE puts the secondary circuit (water) in contact with 2 primary circuits (refrigerant). So even if one primary circuit is shut off, each secondary channel is still in contact with a primary channel. These advantages have made the product the natural choice for flexible chillers, climate control applications and high-precision systems food cooling cabinets in supermarkets.
FLEXIBILITY :
7 8
R22 COOLING MODEL
MODEL
NOMINAL COOLING CAPACITY
NORMAL TOTAL INPUT POWER (COOLING)NORMAL RUNNING CURRENT (COOLING) EERREFRIGERANT CONTROL (EXPENSION DEVICE)REFRIGERANT CHARGE POWER SOURCE (OUTDOOR)REFRIGERANT TYPE
Btu/hWWA
W/W
kgV/Ph/Hz
SOUND PRESSURE LEVELUNIT DIMENSIONPACKINGUNIT WEIGHTNOMINAL WATER FLOW RATE
HEIGHT X WIDTH X DEPTHHEIGHT X WIDTH X DEPTH
dBAmm
COOLING
mmkg
I/s/m3/hr
COMPRESSORTYPESTAGE OF CAPACITY CONTROL
PIPINGTYPECONNECTIONHEAD COOLING
mmkPa
TANKCAPACITY / VOLUME MATERIAL
L
UAE020C UAE025C UAE030C UAE040C UAE050C UAE060C
INDO
OR
UN
IT
20,000 24,200 30,000 39,500 48,500 54,0005,860 7,090 8,790 11,580 14,210 15,8302,650 2,680 3,580 4,490 5,080 5,77012.25 12.17 16.41 9.67 9.75 12.012.21 2.65 2.48 2.58 2.80 2.74
1.25 1.80 1.88 2.80 3.15 3.30220-240/1/50 380-415/3/50
CAPILLARY TUBE
R2257 57 58 59 59 59
790 x 1,160 x 460920 x 1,270 x 570
1,140 x 1,160 x 4601,551 x 1,270 x 570
116 123 126 182 189 1960.29 / 1.03 0.33 / 1.20 0.42 / 1.51 0.53 / 1.90 0.67 / 2.40 0.76 / 2.73
ROTARY SCROLL0 - 100% 0 - 100% 0 - 100% 0 - 100% 0 - 100% 0 - 100%
THREAED25.4
79 92 86 114 90 9222 40
MILD STEEL WITH ZINC
R22 AIR COOLED MINI CHILLER SPECIFICATIONR22 HEATPUMP MODEL
MODEL
NOMINAL COOLING CAPACITY
EERCOPREFRIGERANT CONTROL (EXPENSION DEVICE)REFRIGERANT CHARGE POWER SOURCE (OUTDOOR)REFRIGERANT TYPE
Btu/hW
W
W/WW/W
kgV/Ph/Hz
SOUND PRESSURE LEVELUNIT DIMENSIONPACKINGUNIT WEIGHT
NOMINAL WATER FLOW RATE
HEIGHT X WIDTH X DEPTHHEIGHT X WIDTH X DEPTH
dBAmm
COOLING
mmkg
I/s/m3/hr
COMPRESSOR TYPESTAGE OF CAPACITY CONTROL
PIPING
TYPECONNECTION
HEAD COOLINGmmkPa
TANK CAPACITY / VOLUME MATERIAL
L
UAE020CR UAE025CR UAE030CR UAE040CR UAE050CR UAE060CR
INDO
OR
UN
IT
19,000 23,000 27,500 38,000 44,000 50,0005,570 6,740 8,060 11,140 12,900 14,650
22,000 27,000 35,000 43,000 50,000 55,000
2,600 2,790 3,440 4,390 5,100 5,320
2.20 2.52 3.44 2.63 2.48 2.63
1.43 1.75 1.83 3.50 4.10 4.00220-240/1/50 380-415/3/50
CAPILLARY TUBE
R2257 57 58 59 59 60
790 x 1,160 x 460920 x 1,270 x 570
1,140 x 1,160 x 4601,551 x 1,270 x 570
116 123 128 189 197 2030.26 / 0.93 0.31 / 1.12 0.39 / 1.39 0.56 / 2.00 0.62 / 2.20 0.64 / 2.50
ROTARY SCROLL0 - 100% 0 - 100% 0 - 100% 0 - 100% 0 - 100% 0 - 100%
THREAED25.4
79 94 92 118 104 110
22 40MILD STEEL WITH ZINC
AA
W
NOMINAL HEATPUMP CAPACITY Btu/hW 6,450 7,910 10,260 12,600 14,650 16,120
2,530 2,670 3,440 4,230 5,190 5,580
11.7811.62
12.1712.70
17.2717.25
9.059.14
9.779.72
12.6011.50
2.48 2.84 3.43 2.87 2.87 3.03
I/s/m3/hrHEATPUMP 0.31 / 1.12 0.38 / 1.38 0.49 / 1.75 0.56 / 2.00 0.62 / 2.20 0.76 / 0.72
HEATPUMP 79 86 73 103 85 87kPa
MODEL
NOMINAL COOLING CAPACITY
EERCOPREFRIGERANT CONTROL (EXPENSION DEVICE)REFRIGERANT CHARGE POWER SOURCE (OUTDOOR)REFRIGERANT TYPE
Btu/hW
W
W/WW/W
kgV/Ph/Hz
SOUND PRESSURE LEVELUNIT DIMENSIONPACKINGUNIT WEIGHT
NOMINAL WATER FLOW RATE
HEIGHT X WIDTH X DEPTHHEIGHT X WIDTH X DEPTH
dBAmm
COOLING
mmkg
I/s/m3/hr
COMPRESSORSTAGE OF CAPACITY CONTROL
PIPING
TYPECONNECTION
HEAD COOLINGmmkPa
INDO
OR
UN
IT
NORMAL RUNNING CURRENT AA
W
NOMINAL HEATPUMP CAPACITY Btu/hW
I/s/m3/hrHEATPUMP
HEATPUMP kPa
UAE080CR80,000
23,45095,000
8,750
2.76
5.00 x 2
63
1,245 x 1,500 x 900
1,452 x 1,732 x 1,032328
27,8408,490
18.4018.90
3.18CAPILLARY TUBE
380-415/3/50R22
95,000
27,840105,000
10,310
2.51
30,77011,100
18.9017.10
2.98
UAE100CR
5.40 + 5.30
63
340
UAE120CR113,000
33,120120,000
12,370
2.74
35,17012,070
26.6026.80
2.86
7.60 x 2
67
480
UAE150CR138,000
40,450132,000
15,020
2.82
38,69014,320
31.4032.20
2.58
6.50 x 2
67
560
1,245 x 1,800 x 1,1501,452 x 2,032 x 1,282
1.13 / 4.05 1.33 / 4.80 1.67 / 6.00 2.00 / 7.20
1.13 / 4.05 1.33 / 4.80 1.67 / 6.00 2.00 / 7.20SCROLL
0 - 100% 0 - 100% 0 - 100% 0 - 100%THREAED
31.75
254 173 188 157229 144 188 157
ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICEALL UNIT ARE BEING TESTED AND COMPLY TO ISO 5151 (NON-DUCTED UNIT) OR ISO 13253 (DUCTED UNIT)
EVAPORATOR
CONDENSOR
TEMPERATURE
ENTERING
LEAVING
AMBIENT
COOLING
12°C
HEATING
40°C
7°C 45°C
35°C 7°C / 6°C
MODEL
NOMINAL COOLING CAPACITY
NORMAL TOTAL INPUT POWER (COOLING)NORMAL RUNNING CURRENT (COOLING) EERREFRIGERANT CONTROL (EXPENSION DEVICE)REFRIGERANT CHARGE POWER SOURCE (OUTDOOR)REFRIGERANT TYPE
Btu/hWWA
W/W
kgV/Ph/Hz
SOUND PRESSURE LEVELUNIT DIMENSIONPACKINGUNIT WEIGHTNOMINAL WATER FLOW RATE
HEIGHT X WIDTH X DEPTHHEIGHT X WIDTH X DEPTH
dBAmm
COOLING
mmkg
I/s/m3/hr
COMPRESSORTYPESTAGE OF CAPACITY CONTROL
PIPINGTYPECONNECTIONHEAD COOLING
mmkPa
INDO
OR
UN
IT
UAE080C65,00024,9108,87017.00 8.87
3.90 x 2380-415/3/50
TXV
R22631,245 x 1,500 x 900
1,452 x 1,732 x 1,032328
0.29 / 1.03SCROLL
0 - 100%THREAED31.75
229
UAE100C95,00027,84010,59018.502.63
4.60 x 2
63
3400.33 / 1.20
0 - 100%
229
UAE120C116,00034,00011,37025.832.99
6.00 x 2380-415/3/50
67
4800.42 / 1.51
0 - 100%
188
1,245 x 1,800 x 1,1501,452 x 2,032 x 1,282
UAE150C138,00040,45014,22031.802.84
7.10 x 2
67
5600.53 / 1.90
0 - 100%
157
ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICEALL UNIT ARE BEING TESTED AND COMPLY TO ISO 5151 (NON-DUCTED UNIT) OR ISO 13253 (DUCTED UNIT)
EVAPORATOR
CONDENSOR
TEMPERATURE
ENTERING
LEAVING
AMBIENT
COOLING
12°C
HEATING
40°C
7°C 45°C
35°C 7°C / 6°C
9 10
HEATPUMPCOOLINGNORMAL TOTAL INPUT POWER
HEATPUMPCOOLING
NORMAL RUNNING CURRENT
HEATPUMPCOOLING
NORMAL TOTAL INPUT POWER
HEATPUMPCOOLING
R407C COOLING MODEL
MODEL
SOUND PRESSURE LEVELUNIT DIMENSIONPACKING
HEIGHT X WIDTH X DEPTHHEIGHT X WIDTH X DEPTH
dBAmmmm
COMPRESSOR
PIPINGTYPE
TANKCAPACITY / VOLUME MATERIAL
L
UAP025C UAP030C UAP040C UAP050C UAP060C
INDO
OR
UN
IT
Btu/h 23,000 26,900 38,500 47,000 50,000NOMINAL COOLING CAPACITYW 6,740 7,880 11,280 13,920 14,650
NORMAL TOTAL INPUT POWER (COOLING) W 2,950 3,770 4,680 5,430 6,040NORMAL RUNNING CURRENT (COOLING) A 13.30 17.41 9.62 10.20 11.28EER W/W 2.29 2.09 2.41 2.56 2.43
REFRIGERANT CHARGE kg 1.72 1.63 3.00 3.30 3.20POWER SOURCE (OUTDOOR) V/Ph/Hz 220-240/1/50 380-415/3/50
REFRIGERANT CONTROL (EXPENSION DEVICE) CAPILLARY TUBE
REFRIGERANT TYPE R407C57 58 59 59 60
790 x 1,160 x 460920 x 1,270 x 570
1,140 x 1,160 x 4601,551 x 1,270 x 570
UNIT WEIGHT kg 123 126 188 189 196NOMINAL WATER FLOW RATE COOLING I/s/m3/hr 0.31 / 1.11 0.38 / 1.36 0.53 / 1.90 0.64 / 2.30 0.69 / 2.50
TYPE SCROLLSTAGE OF CAPACITY CONTROL 0 - 100% 0 - 100% 0 - 100% 0 - 100% 0 - 100%
THREAEDCONNECTION mm 25.4HEAD COOLING kPa 94 93 117 93 110
22 40MULTISTAGE END SUCTION
R407C AIR COOLED MINI CHILLER SPECIFICATION
ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICEALL UNIT ARE BEING TESTED AND COMPLY TO ISO 5151 (NON-DUCTED UNIT) OR ISO 13253 (DUCTED UNIT)
EVAPORATOR
CONDENSOR
TEMPERATURE
ENTERING
LEAVING
AMBIENT
COOLING
12°C
HEATING
40°C
7°C 45°C
35°C 7°C / 6°C
MODEL
SOUND PRESSURE LEVELUNIT DIMENSIONPACKING
HEIGHT X WIDTH X DEPTHHEIGHT X WIDTH X DEPTH
dBAmmmm
COMPRESSOR
PIPINGTYPEIN
DOO
R U
NIT
Btu/hNOMINAL COOLING CAPACITY
WNORMAL TOTAL INPUT POWER (COOLING) WNORMAL RUNNING CURRENT (COOLING) AEER W/W
REFRIGERANT CHARGE kgPOWER SOURCE (OUTDOOR) V/Ph/Hz
REFRIGERANT CONTROL (EXPENSION DEVICE)
REFRIGERANT TYPE
UNIT WEIGHT kgNOMINAL WATER FLOW RATE COOLING I/s/m3/hr
TYPESTAGE OF CAPACITY CONTROL
CONNECTION mmHEAD COOLING kPa
UAP080C
80,00023,4509,43018.002.49
3.90 x 2380-415/3/50
TXV
R407C63
1,245 x 1,500 x 9001,452 x 1,732 x 1,032
3401.14 / 4.10
SCROLL0 - 50 - 100%
THREAED31.75
229
UAP100C
90,00026,38011,21019.222.35
3.80 x 2
63
3401.25 / 4.50
229
0 - 50 - 100%
UAP120C
115,00033,73012,17026.502.77
5.60 x 2
67
4801.67 / 6.00
188
0 - 50 - 100%
1,245 x 1,800 x 1,1501,452 x 2,032 x 1,282
UAP150C
137,00040,15014,97033.002.68
6.00 x 2
67
5602.00 / 7.20
157
0 - 50 - 100%
R407C HEATPUMP MODEL
MODEL
NOMINAL COOLING CAPACITY
(COOLING)
(HEATPUMP) EERCOPREFRIGERANT CONTROL (EXPENSION DEVICE)REFRIGERANT CHARGE POWER SOURCE (OUTDOOR)REFRIGERANT TYPE
Btu/hW
W
W/WW/W
kgV/Ph/Hz
SOUND PRESSURE LEVELUNIT DIMENSIONPACKINGUNIT WEIGHT
NOMINAL WATER FLOW RATE
HEIGHT X WIDTH X DEPTHHEIGHT X WIDTH X DEPTH
dBAmm
COOLING
mmkg
I/s/m3/hr
COMPRESSOR TYPESTAGE OF CAPACITY CONTROL
PIPING
TYPECONNECTION
HEADCOOLING
mmkPa
UAP060CR UAP080CR UAP100CR UAP120CR UAP150CR
INDO
OR
UN
IT
50,000 74,000 87,500 110,000 130,00014,650 21,690 32,240 38,10055,000 90,000 96,000 118,000 144,000
5,570 9,350 12,750 16,100
2.33 2.41 2.55 2.40
4.00 3.70 X 2 4.80 + 4.70 5.80 x 2 6.40 x 2380-415/3/50 380-415/3/50
CAPILLARY TUBE
R407C60 63 63 67 67
1,140 x 1,160 x 4601,551 x 1,270 x 570
1,245 x 1,500 x 900 1,245 x 1,800 x 1,150
203 340 340 480 5600.64 / 2.30 1.03 / 3.70 1.25 / 4.50 1.67 / 6.00 1.89 / 6.80
0 - 100% 0 - 50 -100%THREAED
25.4110 263 193 188 172
(COOLING) (HEATPUMP)
AA
W
NOMINAL HEATPUMP CAPACITY Btu/hW 16,120 26,380 28,140 34,500 42,2006,280 8,990 12,630 15,900
11.6011.50
18.9019.00
27.1026.10
34.4034.80
2.89 2.83 2.71 2.62
I/s/m3/hrHEATPUMP 0.78 / 2.80 1.03 / 3.70 1.25 / 4.50 1.67 / 6.00 1.89 / 6.80
HEATPUMP 87 170 170 188 172
SCROLL
kPa
25,640
11,11011,100
19.0019.102.312.53
1,452 x 1,732 x 1,032 1,452 x 2,032 x 1,282
0 - 50 -100% 0 - 50 -100% 0 - 50 -100%
31.75
ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICEALL UNIT ARE BEING TESTED AND COMPLY TO ISO 5151 (NON-DUCTED UNIT) OR ISO 13253 (DUCTED UNIT)
EVAPORATOR
CONDENSOR
TEMPERATURE
ENTERING
LEAVING
AMBIENT
COOLING
12°C
HEATING
40°C
7°C 45°C
35°C 7°C / 6°C
R410A HEATPUMP MODEL
MODEL
NOMINAL COOLING CAPACITY
(COOLING)
(HEATPUMP) EERCOPREFRIGERANT CONTROL (EXPENSION DEVICE)REFRIGERANT CHARGE POWER SOURCE (OUTDOOR)REFRIGERANT TYPE
Btu/hW
W
W/WW/W
kgV/Ph/Hz
SOUND PRESSURE LEVELUNIT DIMENSIONPACKINGUNIT WEIGHT
NOMINAL WATER FLOW RATE
HEIGHT X WIDTH X DEPTHHEIGHT X WIDTH X DEPTH
dBAmm
COOLING
mmkg
I/s/m3/hr
COMPRESSORTYPESTAGE OF CAPACITY CONTROL
PIPING
TYPECONNECTION
HEAD COOLINGmmkPa
TANK CAPACITY / VOLUME MATERIALL
UAQ020CR UAQ025CR UAQ030CR UAQ040CR UAQ050CR UAQ055CR
INDO
OR
UN
IT
15,700 21,000 24,800 34,000 41,600 45,0004,600 6,150 7,270 10,000 12,200 13,200
21,500 25,000 32,500 43,000 48,000 55,000
2,590 2,790 3,630 4,650 5,150 5,440
1.76 2.23 1.90 2.00 2.30 2.40
1.20 1.725 2.20 4.30 4.20 4.30220-240/1/50 380-415/3/50
CAPILLARY TUBE
R410A58 59 57 59 59 61
790 x 1,160 x 460920 x 1,270 x 570
1,140 x 1,160 x 4601,551 x 1,270 x 570
128 128 128 195 195 1950.24 / 0.86 0.28 / 1.00 0.42 / 1.50 0.50 / 1.80 0.60 / 2.15 0.75 / 2.70
ROTARY TANDEM ROTARY0-100%
THREADED25.4
90 98 93 90 74 70
22 40MILD STEEL WITH ZINC
(COOLING) (HEATPUMP)
AA
W
NOMINAL HEATPUMP CAPACITY Btu/hW 6,300 7,330 9,530 12,600 14,070 16,1202,620 2,760 3,830 5,000 5,310 5,490
11.7611.93
12.7012.90
16.8816.32
7.447.20
7.907.83
8.188.38
2.43 2.63 2.62 2.71 2.73 2.96
I/s/m3/hrHEATPUMP 0.32 / 1.16 0.35 / 1.25 0.42 / 1.50 0.50 / 1.80 0.60 / 2.15 0.75 / 2.70
HEATPUMP 73 90 80 71 64 53
0-100% 0-50-100% 0-40-60-100% 0-50-100%0-40-60-100%
kPa
ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICEALL UNIT ARE BEING TESTED AND COMPLY TO ISO 5151 (NON-DUCTED UNIT) OR ISO 13253 (DUCTED UNIT)
EVAPORATOR
CONDENSOR
TEMPERATURE
ENTERING
LEAVING
AMBIENT
COOLING
12°C
HEATING
40°C
7°C 45°C
35°C 7°C / 6°C
R410A AIR COOLED MINI CHILLER SPECIFICATION
11 12
NORMAL TOTAL INPUT POWER
NORMAL RUNNING CURRENT
NORMAL TOTAL INPUT POWER
NORMAL RUNNING CURRENT
SMART MANAGER CONTROLLER
Chiller Network BUSFan Coil Network BUS
By adopting the Daikin chilled water system, the comfort in residential and light commercial buildings such as offices, hospital, restaurant, hotel and shopping complex can be controlled and managed from just one point, that is through the Smart Manager.
The Smart Manager is acting as a central command to manage the operation of both the chilled water fan coil units and the chillers.
Besides allowing the user to have customized control for each connected unit, the Smart Manager is also able to manage the overall system operating mode of all units based on the air conditioning system load demand of the building.
SUPPORTED UP TO 50 CHILLERS & 120 FAN COIL UNITSThrough the versatile Smart Manager controller, the operation of each equipments in the Daikin chilled water system connected through the chiller Bus and Daikin own proprietary NIM BUS can be managedand controlled.
NIM
CHILLER CHILLER CHILLER
Up to50 unitsof Chiller
Up to120 unitsof FCUs
AB
AB
CHILLER BUS
NIM BUS
Smart Manager Controller
NIM NIM
FCU FCU FCU WIREDCONTROLLER
CHILLERPANEL
CHILLERPANEL
CHILLERPANEL
Alarm 1(Ch 0)
Comp 1 overload
01/01/00 12.00am
DISPLAY UP TO 46 TYPES OF CHILLER FAULT /ALARM AND 6 TYPES OF FCU FAULT / ALARM
Whenever a fault occurred in either the chiller or fan coil unit, a signal will be sent to Smart Manager and an alarm message willappear on the LCD, showing type of alarm, alarm occured time,date and unit.
This will greatly ease the troubleshooting process and thus reduce the valuable time of service technicians.
As soon as the fault is solved, the alarm will automaticallydissolve from the LCD.
8.00am
9.00am
10.00am
11.00am
12.00am
1.00pm
2.00pm
3.00pm
4.00pm
5.00pm
6.00pm
7.00pm
8.00am
9.00am
10.00am
11.00am
12.00am
1.00pm
2.00pm
3.00pm
4.00pm
5.00pm
6.00pm
7.00pm
Time
FWC
FWK
FWE 2
FWE 1
FWW
Uni
t
The operation of the chiller and each fan coil unit can be preset to operate and tostop at different time schedule and at different day of a week. Taking considerationof the fact that certain rooms in a buildingwill be empty at certain period of the day,setting timer to On and to Off the operationof units in those areas will greatly reducethe energy cost of the building.
At the same time, Smart Manager allowssetting of up to five sets of 7 days programmable operation schedules (2 On/Off timer per day) for each fan coil unit
ENERGY SAVING PROGRAMMABLE TIMER
13 14
If the priority setting is being preset to fan coil unit, the
operating mode of the complete Daikin chilled water system can be synchronized to operate under one same mode. This is achievable through the unique feature called “Threshold Value Setting”
Smart Manager can command chiller operating mode to switch from current operating mode if the threshold value is meet.
Example,In a network of 10 fan coil units that is currently operating in COOL mode and a threshold of 60% was set for COOL mode and threshold of 50% was set for HEAT mode. Should 6 of the fan coil units are requesting for HEAT mode then the threshold for HEAT is crossed. Signal will be sent by Smart Manager to chiller BUS to switch the operating mode of all chillers to HEAT mode. Requirement of users will be met.
FWW
FWE 2FWK
FWC
FWE 1
THRESHOLD VALUE SETTING
• Heat Treshold •
Chiller to operate atHeat Mode
Chiller to operate atCool Mode
0 1 2 3 4 5 6 7 8 9 10
• Cool Treshold •
Depending on the application requirement, Smart Manager controller offers the flexibility to allow user to set the priority on the operation of fan coil unit and Chiller in a complete Daikin chilled water product system.
If priority is set to fan coil unit, the chiller will be forced to OFF if all fan coil units are OFF. If Chiller Priority is being set, all fan coil units will be OFF if chillers are OFF.
PRIORITY SETTING
When there is power failure occurs during operation, Smart Manager Controller will load the last state memory from EEPROM after power On reset.
Besides, extra memory space inside the Smart Manager controller will allow user to view the previous alarm records even though its have been dissolved. This useful information will benefit the service technician to view the history of maintenance record done to the unit.
MEMORY BACKUP (EEPROM),ALARM MEMORY FOR CHILLER AND FCU KEY PARAMETER DISPLAY
For easy serviceability and maintenance, Smart Manager Controller's is able to display the key parameter such as defrost and compressor discharge sensor temperature, water in/out temperature, status of compressor On/Off, Cool/Heat mode water in temperature, etc. Thus, it reduces the cumbersome of requiring the service technicians to physically go to site of chiller installation to do the troubleshooting process.
A Daikin chilled water product system with key parameters that were set by personnel to optimize operating conditions will need to be protected against any unauthorized disturbance or changes. The built in “Password Settings” feature will prevent the losing of key parameter settings in the Smart Manager controller as well as the chiller panel
PASSWORD PROTECTION FOR ADVANCED PARAMETER SETTINGS (CHILLER)
HOLIDAY SETTINGSHoliday 1Holiday 2Holiday 3Holiday 4Holiday 5
Set Holiday 1Month : 1Day : 1Duration : Disable
While designing the Smart Manager, the practical aspects of equipment application were always the key points to be considered. Thus resulting in the creation of “Holiday Setting” feature.
In this feature, users are allowed to set up to 10 holiday timers with each timer can last for duration of 99 days.
During the duration of Holiday Timer set earlier, all fan coil units and chiller will automatically be turned Off.
15 16
HOLIDAY SETTING
Smart Manager controller will turn into low power mode during electricity power breakdown. It will operate based on the built in backup battery and only one timer and interrupt is active. CPU operation is Off and no display on LCD as well for energy saving purpose.
LOW POWER MODE (CHILLER + FCU)
User can also check the compressor run time of chiller in Smart Manager Controller. It will provide a guideline as well as posting a reminder for requirement of routine system service.
RTC will always appear at the summary pages and the user is able to set the time and date.
ACCUMULATIVE COMPRESSOR RUN TIME
REAL TIME CLOCK (RTC)
17 18
To complement the new innovative Smart Manager range of air cooled chillers, Daikin is offering an extensive range of chilled water fan coil units that will meet most of indoor application requirements covering residential, light commercial and commercial.
The aesthetically attractive decorative fan coil units such as Wall Mounted models, Ceiling Cassette and Ceiling Convertible are compact and ergonomic, the ranges can blend in easily to any interior designs whether it is residential houses, office, restaurant or shops.
In addition, the Daikin chilled water fan coil units are designed with easy installation and easy servicing in mind. The fan coil units also include the microprocessor controller that has built in algorithm to control the operation of the fan coil unit as well as to provide protection to the unit.
Wall Mounted TypeAL
› Stylish Front Panel › Comfortable Air Flow & Lower Sound Level› Indoor Quiet Mode› Turbo Mode› Uniform Air Distribution› Easy Maintenance› Wide Capacity Range› 5 Selectable Fan Speed
› NIM-Able › Sleep Funtion For Cool & Heat Mode › Auto Restart With Last-State-Memory› Vlave & Vlaveless Control Options › Self Diagnosis Features› Compact & Easy To Use Wireless Remote Controller› Microprocessor Control› Automatic Air Swing
Specification for Wall Mounted Type
Btu/h 8300 9200 11300 15500 18000
W 2430 2700 3310 4540 5280
Btu/h 6300 6900 9000 11700 14000
W 1850 2020 2640 3430 4100
Btu/h 11000 12000 15000 20500 25000
W 3220 3520 4400 6010 7330
W 31 32 42 57 72
A 0.20 0.20 0.21 0.30 0.34
V/Ph/Hz
CFM 260 280 370 510 620
CFM 230 250 320 450 520
CFM
CFM
200
180
220
190
260
240
390
360
460
440
USGPM 1.85 2.03 2.51 3.43 4.01
litres/min 7.00 7.68 9.50 13.00 15.18
kPa 34.0 24.0 31.0 30.0 36.0
kPa 29.0 20.0 25.0 27.0 33.0
kPa
m/s 0.68 0.74 0.97 0.83 1.01
dBA 34 / 29 / 25 / 24 35 / 30 / 25 / 24 42 / 39 / 32 / 29 42 / 38 / 34 / 32 46 / 42 / 39 / 37
H X W X D mm
H X W X D mm
kg
mm
mm
310 X 1065 X 224
14
1608
288 X 800 X 206
344 x 874 x 274
9
386 X 1136 X 314PACKING DIMENSION
UNIT WEIGHT
CONDENSATE DRAIN SIZE 19.05
PIPE CONNECTION
MEDIUM
LOW
QUIET
NOMINAL WATER FLOW RATE
12.70
HEAD LOSS (COOLING)
HEAD LOSS (HEATING) : 50˚C
MAX. WORKING PRESSURE
SURFACE AIR VELOCITY
SOUND PRESSURE LEVEL (H/M/L/Q)
UNIT DIMENSION
220-240 / 1 / 50
REFRIGERANT TYPE N/A
INDO
OR
UN
IT
CONTROLAIR DISCHARGE AUTOMATIC LOUVER (UP & DOWN)
OPERATION LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL
NOMINAL COOLING CAPACITY
NOMINAL SENSIBLE COOLING CAPACITY
NOMINAL HEATING CAPACITY(ENTERING WATER TEMP. = 50°C)
NOMINAL TOTAL INPUT POWER
NOMINAL RUNNING CURRENT
POWER SOURCE
AIR FLOW
HIGH
FWW02L FWW03L FWW04L FWW05L FWW06LMODEL
FWW-LWireless Remote Controller
BRC52A Wired Remote Controller
BRC51A (Option)
ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE
27°c DB / 19°c WB 20°c DB
7°c50°c (2 PIPES SYSTEM)
12°c
70°c (4 PIPES SYSTEM)
ENTERING AIR TEMPRATURE
MODE COOLING HEATING
60°c (4 PIPES SYSTEM)
ENTERING WATER TEMPRATURE
LEAVING WATER TEMPRATURE
AL*
Ceiling Cassette Compact Type (600x600)
Specification for Ceiling Cassette Compact Type
Btu/h 8500 14000 15500
W 2490 4100 4540
Btu/h 6500 10000 11500
W 1910 2930 3370
Btu/h 12000 16000 18000
W 3520 4690 5280
W 63 64 79
A 0.28 0.28 0.35
V/Ph/Hz
CFM 380 400 440
CFM 290 310 330
CFM 230 220 280
USGPM 2.03 3.43 3.57
litres/min 7.68 12.98 13.51
kPa 19.3 26.9 28.8
kPa 16.8 23.9 26.5
kPa
m/s 0.75 0.76 0.83
dBA 42 / 35 / 29 45 / 38 / 30 48 / 40 / 36
H X W X D mm
H X W X D mm
kg 15 + 3 17 + 3 17 + 3
mm
mm 19.05
19.05
250 X 570 X 570 (295 X 640 X 640)
220-240 / 1 / 50
LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL
4 WAY AUTOMATIC LOUVER (UP & DOWN)
N/A
316 X 630 X 630 (126 X 700 X 726)
1608
CONDENSATE DRAIN SIZE
PIPE CONNECTION
HEAD LOSS (COOLING)
HEAD LOSS (HEATING) : 50°C
MAX. WORKING PRESSURE
SURFACE AIR VELOCITY
SOUND PRESSURE LEVEL (H/M/L)
UNIT DIMENSION - ( ) WITH PANEL
NOMINAL COOLING CAPACITY
NOMINAL SENSIBLE COOLING CAPACITY
NOMINAL HEATING CAPACITY(ENTERING WATER TEMP. = 50°C)
NOMINAL TOTAL INPUT POWER
AIR FLOW
HIGH
MEDIUM
LOW
POWER SOURCE
NOMINAL RUNNING CURRENT
INDO
OR
UN
IT
CONTROLAIR DISCHARGE
OPERATION
NOMINAL WATER FLOW RATE
REFRIGERANT TYPE
PACKING DIMENSION - ( ) PANEL
UNIT WEIGHT (UNIT + PANEL)
› Compact Design › Fresh Air Intake › Built In High Head Drain Oump & Water Flow Switch › 4 Way Air Discharge & Air Swing› Valve Or Valveless Control Options› 3 Selectable Fan Speed› Microprocessor Control
› Branch Duct Connection › Sleep Function For Cool & Heat Mode › Auto Restart With Last-State-Memory› NIM-Able › Choice Of Wired Or Withless Remote Controller› Automatic Air Swing
FWF02C FWF04C FWF05CMODEL
FWF-C Wireless Remote Controller BRC52A
Wired Remote ControllerBRC51A (Option)
ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE
27°c DB / 19°c WB 20°c DB
7°c50°c (2 PIPES SYSTEM)
12°c
70°c (4 PIPES SYSTEM)
ENTERING AIR TEMPRATURE
MODE COOLING HEATING
60°c (4 PIPES SYSTEM)
ENTERING WATER TEMPRATURE
LEAVING WATER TEMPRATURE
19 20
Ceiling Cassette Type (900x900) With Brushless DC MotorAL
*
Specification for Ceiling Cassette Type
QUIET LOW MEDIUM HIGH QUIET LOW MEDIUM HIGH QUIET LOW MEDIUM HIGH
Btu/h 8200 11900 15900 20100 15200 19800 24700 30000 21000 26800 33100 40100
W 2400 3500 4650 5900 4550 5800 7250 8800 6150 7850 9700 11750
Btu/h 5800 8700 11700 15400 11000 14500 18500 21900 14600 18900 23800 28600
W 1710 2540 3440 4510 3220 4260 5410 6430 4270 5540 6970 8370
Btu/h 11300 15200 19800 24200 18400 23900 30400 38200 24100 31600 39100 46700
W 3300 4450 5800 7100 5400 7000 8900 11200 7050 9250 11450 13700
W 7 12 19 37 17 26 50 90 23 39 83 120
A 0.11 0.13 0.19 0.26 0.19 0.28 0.43 0.74 0.21 0.35 0.55 0.95
V/Ph/Hz
CFM 220 350 470 620 420 560 720 890 510 680 870 1060
Pa
USGPM 1.84 2.68 3.56 4.52 3.41 4.44 5.55 6.74 4.71 6.01 7.43 9.00
Litres/min 6.96 10.15 13.48 17.10 12.90 16.81 21.02 25.51 17.83 22.76 28.12 34.06
kPa 5 10 15 24 7 9 14 20 15 22 30 41
kPa 4 8 13 21 5 8 12 18 12 20 26 37
kPa
m/s 0.27 0.42 0.60 0.64 0.43 0.55 0.68 0.81 0.45 0.57 0.71 0.83
dBA 16 23 31 37 31 37 42 47 34 41 46 51
H X W X D mm
H X W X D mm
kg
mm
mm
NOMINAL COOLING CAPACITY
NOMINAL SENSIBLE COOLING CAPACITY
NOMINAL HEATING CAPACITY(ENTERING WATER TEMP. = 50˚C)
FAN INPUT POWER
NOMINAL RUNNING CURRENT
POWER SOURCE
REFRIGERANT TYPE
CONTROLAIR DISCHARGE
OPERATION
AIR FLOW
EXTERNAL STATIC PRESSURE (H/M/L)
NOMINAL WATER FLOW RATE
HEAD LOSS (COOLING)
HEAD LOSS (HEATING) : 50˚C
MAX. WORKING PRESSURE
SURFACE AIR VELOCITY
SOUND PRESSURE LEVEL
UNIT DIMENSION - ( ) WITH PANEL
PACKING DIMENSION - ( ) PANEL
UNIT WEIGHT
CONDENSATE DRAIN SIZE
PIPE CONNECTION
220-240 / 1 / 50
N/A
4 WAY AUTOMATIC LOUVER (UP & DOWN)
LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL
1608
N/A
265 X 820 X 820 (340 X 990 X 990)
341 X 916 X 916 (125 X 1020 X 1020)
300 X 820 X 820 (375 X 990 X 990)
376 X 916 X 916 (125 X 1020 X 1020)
26 + 4 28 + 4 32 + 4
19.05
19.05
INDO
OR
UN
IT
FWKE05E FWKE08EMODEL
FWKE11E
FWKE-E Wireless Remote Controller BRC52A
Wired Remote ControllerBRC51A (Option)
Ceiling Cassette Type (900x900)AL
*
Specification for Ceiling Cassette Type
Btu/h 21000 25000 30000 38000 43000
W 6150 7330 8790 11140 12600
Btu/h 16700 19200 22300 27400 31000
W 4890 5630 6540 8030 9090
Btu/h 28000 33600 38300 45500 52000
W 8210 9850 11230 13340 15240
W 95 126 167 186 227
A 0.44 0.55 0.74 0.85 1.03
V/Ph/Hz
CFM 750 860 890 1000 1140
CFM 620 700 720 840 1000
CFM 480 540 570 680 840
CFM 320 380 420 540 700
USGPM 4.71 5.59 6.69 8.45 9.60
litres/min 17.83 21.17 25.29 31.94 36.29
kPa 20 37 22 44 53
kPa 19 33 19 38 47
kPa
m/s 0.91 1.04 1.14 1.03 1.17
dBA 42/38/32/23 46/42/35/27 48/43/38/30 50/47/43/33 52/49/45/39
H X W X D mm
H X W X D mm
kg 26 + 4 26 + 4 28 + 4 32 + 4 32 + 4
mm
mm
1600
UNIT DIMENSION - ( ) WITH PANEL
PACKING DIMENSION - ( ) PANEL
19.05
UNIT WEIGHT (UNIT + PANEL)
CONDENSATE DRAIN SIZE
19.05PIPE CONNECTION
INDO
OR
UN
IT
CONTROLAIR DISCHARGE 4 WAY AUTOMATIC LOUVER (UP & DOWN)
HEAD LOSS (COOLING)
HEAD LOSS (HEATING) : 50°C
MAX. WORKING PRESSURE
SURFACE AIR VELOCITY
SOUND PRESSURE LEVEL (H/M/L/Q)
LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL
AIR FLOW
HIGH
MEDIUM
QUIET
OPERATION
NOMINAL COOLING CAPACITY
NOMINAL SENSIBLE COOLING CAPACITY
NOMINAL HEATING CAPACITY(ENTERING WATER TEMP. = 50°C)
NOMINAL TOTAL INPUT POWER
NOMINAL RUNNING CURRENT
265 X 820 X 820 (340 X 990 X 990) 300 X 820 X 820 (375 X 990 X 990)
341 X 916 X 916 (125 X 1020 X 1020) 376 X 916 X 916 (125 X 1020 X 1020)
NOMINAL WATER FLOW RATE
POWER SOURCE
LOW
220-240 / 1 / 50
REFRIGERANT TYPE N/A
› Modern & Elegant Panel› Optimum Air Discharge › Automatic Air Swing › 4 Way Air Discharge & Air Swing› Multi Comfort - 3 Air Swing Pattern Control › Fresh Air Intake › Built In High Head Drain Oump & Water Flow Switch › Valve Or Valveless Control Options› 4 Selectable Fan Speed
› Branch Duct Connection› Low Height Design› Superior Sound Level › Sleep Function For Cool & Heat Mode › Auto Restart With Last-State-Memory› NIM-Able › Choice Of Wired Or Withless Remote Controller› Self Diagnosis Features › Microprocessor Control
FWK06E FWK08E FWK09E FWK11E FWK13EMODEL
FWK-E Wireless Remote Controller BRC52A
Wired Remote ControllerBRC51A (Option)
NOTE :A) BASED ON EUROVENT CONDITIONSB) ADDITIONAL 10W IS REQUIRED FOR CONDENSATE DRAIN PUMPC) SOUND PRESSURE LEVEL IS TESTED AS PER JIS STANDARD AS BELOW :FWKE05E MODEL - 1.4M BELOW THE FACE CENTER OF AIR RETURN OF THE UNIT FWKE08/11E MODEL - 1.5M BELOW THE FACE CENTER OF AIR RETURN OF THE UNIT
27°c DB / 19°c WB 20°c DB
7°c50°c (2 PIPES SYSTEM)
12°c
70°c (4 PIPES SYSTEM)
ENTERING AIR TEMPRATURE
MODE COOLING HEATING
60°c (4 PIPES SYSTEM)
ENTERING WATER TEMPRATURE
LEAVING WATER TEMPRATURE
21 22
› Comfortable› Energy Saving› Low Noise› Low Maintenance & No Brush Sparking› Modulating Fan Speed Control› Modern & Elegant Panel› Optimum Air Discharge › Automatic Air Swing › 4 Way Air Discharge & Air Swing
› Auto Restart With Last-State-Memory› NIM-Able › Choice Of Wired Or Withless Remote Controller› Self Diagnosis Features › Microprocessor Control› 4 Pipe System Model : FWKE-EH
› Multi Comfort - 3 Air Swing Pattern Control › Fresh Air Intake › Built In High Head Drain Oump & Water Flow Switch › Valve Or Valveless Control Options› 4 Selectable Fan Speed› Branch Duct Connection› Low Height Design› Superior Stound Level › Sleep Function For Cool & Heat Mode
Specification for Ceiling Cassette Type (4 Pipe System)
QUIET LOW MEDIUM HIGH QUIET LOW MEDIUM HIGH QUIET LOW MEDIUM HIGH
Btu/h 6800 9600 12300 15000 13300 17100 20800 24600 17700 22200 26400 30700
W 2000 2800 3600 4400 3900 5000 6100 7200 5200 6500 7750 9000
Btu/h 5300 7600 10200 13100 9900 13000 16600 19600 13300 16700 20700 24500
W 1560 2240 2990 3850 2910 3810 4850 5750 3890 4900 6060 7170
Btu/h 12800 17200 21700 26100 21800 27300 32800 38200 31900 39100 46200 53400
W 3750 5050 6350 7650 6400 8000 9600 11200 9350 11450 13550 15650
W 7 12 19 37 17 26 50 90 23 39 83 120
A 0.11 0.13 0.19 0.26 0.19 0.28 0.43 0.74 0.21 0.35 0.55 0.95
V/Ph/Hz
CFM 220 350 470 620 420 560 720 890 510 680 870 1060
Pa
USGPM 1.53 2.14 2.76 3.37 2.99 3.83 4.67 5.51 3.98 4.98 5.93 6.89
Litres/min 5.80 8.12 10.44 12.75 11.31 14.49 17.68 20.87 15.07 18.84 22.47 26.09
USGPM 1.44 1.93 2.43 2.93 2.45 3.06 3.68 4.29 3.58 4.38 5.19 5.99
Litres/min 5.44 9.20 9.20 11.09 9.28 13.91 13.91 16.23 13.55 16.60 19.64 22.68
kPa 5 9 13 18 6 10 15 19 12 19 24 32
kPa 7 10 17 22 13 18 25 32 21 30 39 52
kPa
m/s 0.27 0.42 0.60 0.64 0.43 0.55 0.68 0.81 0.45 0.57 0.71 0.83
dBA 16 23 31 37 31 37 42 47 34 41 46 51
H X W X D mm
H X W X D mm
kg
mm
mm
NOMINAL WATER FLOW RATE (COOLING)
SURFACE AIR VELOCITY
SOUND PRESSURE LEVEL
UNIT DIMENSION - ( ) WITH PANEL
PACKING DIMENSION - ( ) PANEL
CONDENSATE DRAIN SIZE
PIPE CONNECTION
MODELFWKE05EH FWKE08EH
POWER SOURCE
REFRIGERANT TYPE
INDO
OR
UN
IT
CONTROLAIR DISCHARGE
UNIT WEIGHT
OPERATION
AIR FLOW
EXTERNAL STATIC PRESSURE (H/M/L)
NOMINAL WATER FLOW RATE (HEATING)
FWKE11EH
NOMINAL SENSIBLE COOLING CAPACITY
NOMINAL HEATING CAPACITY
(ENTERING WATER TEMP. = 70˚C)
FAN INPUT POWER
NOMINAL RUNNING CURRENT
NOMINAL COOLING CAPACITY
HEAD LOSS (COOLING)
HEAD LOSS (HEATING) : 70˚C
MAX. WORKING PRESSURE
220-240 / 1 / 50
N/A
4 WAY AUTOMATIC LOUVER (UP & DOWN)
LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL
N/A
1608
265 X 820 X 820 (340 X 990 X 990) 300 X 820 X 820 (375 X 990 X 990)
341 X 916 X 916 (125 X 1020 X 1020) 376 X 916 X 916 (125 X 1020 X 1020)
26 + 4 28 + 4 32 + 4
19.05
19.05
NOTE :A) BASED ON EUROVENT CONDITIONSB) ADDITIONAL 10W IS REQUIRED FOR CONDENSATE DRAIN PUMPC) SOUND PRESSURE LEVEL IS TESTED AS PER JIS STANDARD AS BELOW :FWKE05EH MODEL - 1.4M BELOW THE FACE CENTER OF AIR RETURN OF THE UNIT FWKE08/11EH MODEH - 1.5M BELOW THE FACE CENTER OF AIR RETURN OF THE UNIT
27°c DB / 19°c WB 20°c DB
7°c50°c (2 PIPES SYSTEM)
12°c
70°c (4 PIPES SYSTEM)
ENTERING AIR TEMPRATURE
MODE COOLING HEATING
60°c (4 PIPES SYSTEM)
ENTERING WATER TEMPRATURE
LEAVING WATER TEMPRATURE
23
FWE-E
Wireless Remote ControllerBRC52A
Wired Remote ControllerBRC51A
Ceiling Convertible Type
› Compact Design› Far Air Throw› Auto Air Swing› Service & Maintenance At Ease› Ceiling & Floor Installing Option› Versatile Installation› Room Temperature Sensing› 3 Selectable Fan Speed
› Saranet Filter› Sleep Function For Cool And Heat Mode› Auto Restart With Last-State-Memory› Valve Or Valveless Control Options› Self Diagnosis Features› NIM-Able› Choices Of Wired Or Wireless Remote Controller› Microprocessor Control
Specification for Ceiling Convertible Type
FWE05E FWE06E FWE07E FWE08E FWE10E FWE12E
Btu/h 15500 20300 21000
W 4540 5950 6150
24800
7270
34500
10110
46300
13570
51600
15120
33700
9880
40000
11720
Btu/h 12700 15400 16150
W 3720 4510 4730
Btu/h 19500 25000 28000
W 5720 7330 8210
W 86 135 160
A 0.38 0.67 0.79
V/Ph/Hz
CFM 520 580 640
CFM 460 530 560
CFM 406 490 460
USGPM 3.43 4.49 4.67
Litres/min 13 17 17.68
kPa 27 48 57
kPa 24 42 50
kPa
m/s 0.87 1.01 1.08
dBA 45 / 38 / 36 46 / 43 / 39 49 / 46 / 41
H X W X D mm
H X W X D mm
kg
mm
mm
NOMINAL TOTAL INPUT POWER
MODEL
NOMINAL COOLING CAPACITY
NOMINAL SENSIBLE COOLING CAPACITY
NOMINAL HEATING CAPACITY(ENTERING WATER TEMP. = 50 ⁰C)
INDO
OR
UN
IT
CONTROLAIR DISCHARGE AUTOMATIC LOUVER (UP & DOWN)
OPERATION LCD WIRELESS MICRO-COMPUTERREMOTE CONTROL
AIR FLOW
HIGH
MEDIUM
LOW
UNIT WEIGHT 27
NOMINAL WATER FLOW RATE
HEAD LOSS (COOLING)
HEAD LOSS (HEATING) : 50⁰C
MAX. WORKING PRESSURE
NOMINAL RUNNING CURRENT
POWER SOURCE 220-240 / 1 / 50
REFRIGERANT TYPE N/A
1608
SURFACE AIR VELOCITY
SOUND PRESSURE LEVEL (H/M/L)
UNIT DIMENSION 212 X 1090 X 630
PACKING DIMENSION 297 X 1197 X 740
CONDENSATE DRAIN SIZE 19.05
PIPE CONNECTION 12.7
COMI
NG SO
ON
COMING SOON
ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE
27°c DB / 19°c WB 20°c DB
7°c50°c (2 PIPES SYSTEM)
12°c
70°c (4 PIPES SYSTEM)
ENTERING AIR TEMPRATURE
MODE COOLING HEATING
60°c (4 PIPES SYSTEM)
ENTERING WATER TEMPRATURE
LEAVING WATER TEMPRATURE
AL
*
24
AL*
Ceiling Concealed Type
› Excellent Air Distribution› Compaot Design› High Capacity Range› High External Static Pressure Range› Double Protection Drainage › Easy To Service › Left/Right Piping Option› Wide Capacity Range
› Choices Of With Or Without Wired Handset› 4 Useable Fan Speed› Self Diagnosis Features› NIM-Able› Auto Restart With Last-State-Memory› Valve Or Valveless Control Option› 4 Speed Fan Motor For Application Flexibility
Specification for Ceiling Concealed Type
FWC03C FWC04C FWC06C FWC07C
Btu/h 9900 11600 18000 22500
W 2900 3400 5280 6590
Btu/h 7000 8120 12600 15750
W 2050 2380 3690 4620
Btu/h 11500 15000 23000 29000
W 3370 4400 6740 8500
W 89 140 168 182
A 0.40 0.65 0.77 0.86
V/Ph/Hz
CFM 300 510 700 730
CFM 285 490 675 660
CFM 260 400 640 580
Pa 49 / 44 / 36 49 / 42 / 28 49 / 45 / 41 49 / 43 / 30
USGPM 2.20 2.60 4.05 5.06
litres/min 8.33 9.84 15.33 19.15
kPa 10.5 24.0 20.1 32.4
kPa 8.8 20.3 17.0 27.6
kPa
m/s 1.29 1.72 1.83 1.72
dBA 36 / 35 / 33 40 / 38 / 33 42 / 41 / 40 41 / 40 / 36
H X W X D mm 267 x 702 x 351 267 x 842 x 351 267 x 1002 x 351 267 x 1137 x 351
H X W X D mm 376 x 951 x 541 376 x 1091 x 541 376 x 1251 x 541 376 x 1386 x 541
kg 18 22 24 26
mm
mmPIPE CONNECTION
1608
19.05
PACKING DIMENSION
UNIT WEIGHT
CONDENSATE DRAIN SIZE 19.05
HEAD LOSS (HEATING) : 50°C
MAX. WORKING PRESSURE
SURFACE AIR VELOCITY
SOUND PRESSURE LEVEL (H/M/L)
UNIT DIMENSION
HIGH
MEDIUM
LOW
NOMINAL WATER FLOW RATE
EXTERNAL STATIC PRESSURE
HEAD LOSS (COOLING)
REFRIGERANT TYPE N/A
INDO
OR
UN
IT
CONTROLAIR DISCHARGE DUCTED
OPERATION WIRED MICRO-COMPUTER REMOTE CONTROL
AIR FLOW
POWER SOURCE 220-240 / 1 / 50
MODEL
NOMINAL COOLING CAPACITY
NOMINAL SENSIBLE COOLING CAPACITY
NOMINAL HEATING CAPACITY(ENTERING WATER TEMP. = 50°C)
NOMINAL TOTAL INPUT POWER
NOMINAL RUNNING CURRENT
Specification for Ceiling Concealed Type
FWC09C FWC11C FWC12C FWC14C FWC16C
Btu/h 24800 38000 37000 44700 51800
W 7270 11140 10840 13100 15180
Btu/h 19700 29800 29300 35100 40900
W 5770 8730 8590 10290 11990
Btu/h 32800 49200 48000 54900 65300
W 9610 14420 14070 16090 19140
W 345 504 442 427 531
A 1.50 2.28 1.93 1.86 2.32
V/Ph/Hz
CFM 830 1250 1240 1340 1550
CFM 760 1130 1100 1220 1400
CFM 710 1040 1020 1190 1300
Pa 167 / 128 / 88 118 / 108 / 88 128 / 88 / 39 157 / 137 / 108 157 / 137 / 98
USGPM 5.55 8.59 8.28 10.04 11.62
litres/min 21.01 32.51 31.34 38.00 43.98
kPa 14.0 39.0 23.0 38.0 51.0
kPa 11.0 37.0 19.0 33.0 48.0
kPa
m/s 1.40 1.74 1.83 1.54 1.52
dBA 46 / 42 / 38 51 / 48 / 45 49 / 45 / 41 52 / 50 / 47 53 / 50 / 47
H X W X D mm 384 x 917 x 462 316 x 1225 x 559 384 x 1003 x 462 384 x 1287 x 462 384 x 1487 x 462
H X W X D mm 415 x 1126 x 631 355 x 1461 x 727 415 x 1245 x 631 415 x 1497 x 631 415 x 1701 x 631
kg 42 47 44 50 56
mm
mm
19.05
1608
19.05PIPE CONNECTION
MAX. WORKING PRESSURE
SURFACE AIR VELOCITY
SOUND PRESSURE LEVEL (H/M/L)
UNIT DIMENSION
PACKING DIMENSION
UNIT WEIGHT
CONDENSATE DRAIN SIZE
WIRED MICRO-COMPUTER REMOTE CONTROL
HIGH
MEDIUM
LOW
NOMINAL WATER FLOW RATE
HEAD LOSS (COOLING)
AIR FLOW
220-240 / 1 / 50
REFRIGERANT TYPE N/A
INDO
OR
UN
IT
CONTROLAIR DISCHARGE DUCTED
OPERATION
MODEL
NOMINAL COOLING CAPACITY
NOMINAL SENSIBLE COOLING CAPACITY
NOMINAL HEATING CAPACITY (ENTERING WATER TEMP. = 50°C)
NOMINAL TOTAL INPUT POWER
NOMINAL RUNNING CURRENT
EXTERNAL STATIC PRESSURE
POWER SOURCE
HEAD LOSS (HEATING) : 50°C
FWC-C Wired Remote ControllerBRC51A
ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE
27°c DB / 19°c WB 20°c DB
7°c50°c (2 PIPES SYSTEM)
12°c
70°c (4 PIPES SYSTEM)
ENTERING AIR TEMPRATURE
MODE COOLING HEATING
60°c (4 PIPES SYSTEM)
ENTERING WATER TEMPRATURE
LEAVING WATER TEMPRATURE
25 26
AL
* *
Ducted Blower Type
Specification for Ducted Blower Type
FUD20B FUD25B FUD30B FUD40B
Btu/h 75600 95000 125000 150000
W 22160 27840 36640 43960
Btu/h 53700 69400 90000 106500
W 15740 20340 26380 31210
Btu/h 78000 97500 138000 170000
W 22860 28580 40450 49820
W 760 1800 1620 1910
A 3.49 7.84 3.33 4.03
V/Ph/Hz
CFM 2500 3200 4200 4600
CFM 2100 3000 N/A N/A
CFM 1750 2800 N/A N/A
Pa 100 / 72 / 50 100 / 80 / 60 230 230
USGPM 16.90 21.10 27.70 33.30
litres/min 64.00 80.00 105.00 126.00
kPa 34.5 42.0 48.8 53.3
kPa 32.9 27.4 31.5 63.2
kPa
m/s 2.19 2.80 1.96 2.15
dBA 50/46/42 54/52/50 58 58
H X W X D mm
H X W X D mm
kg 92 102 176 189
mm
mm
380-415 / 3 / 50220-240 / 1 / 50
1608
PIPE CONNECTION
UNIT WEIGHT
CONDENSATE DRAIN SIZE 19.05
28.58
762 x 1605 x 880
885 x 1540 x 850
1154 x 1787 x 1188
HEAD LOSS (COOLING)
HEAD LOSS (HEATING) : 50°C
MAX. WORKING PRESSURE
SURFACE AIR VELOCITY
SOUND PRESSURE LEVEL
UNIT DIMENSION
PACKING DIMENSION
HIGH
MEDIUM
LOW
NOMINAL WATER FLOW RATE
EXTERNAL STATIC PRESSURE
572 x 1402 x 605
N/A
INDO
OR
UN
IT
CONTROLAIR DISCHARGE DUCTED
OPERATION WITHOUT CONTROLLER
AIR FLOW
POWER SOURCE
REFRIGERANT TYPE
MODEL
NOMINAL COOLING CAPACITY
NOMINAL SENSIBLE COOLING CAPACITY
NOMINAL HEATING CAPACITY(ENTERING WATER TEMP. = 50°C)
NOMINAL TOTAL INPUT POWER
NOMINAL RUNNING CURRENT
FUD20/25B FUD40/50B
› Excellent Air Distribution› 4 Useable Fan Speed› Easy To Service› Fire-Resistant Polysthylene Insulation› Left/Right Piping Option› Cabinet Construction› High External Static Pressure Range› ChangeableDrive Package
› Convertible Air Throw Direction› High CFM Range› Wide Capacity Range› 4 Useable Fan Speed Is Applicable For FUD20/25B› Changeable Drive Package Is Applicable For FUD30/40B› Flexibility In Adjusting Air Flow And External Static For FUD30/40B› Convertible Air Throw Direction Is Applicable For FUD30/40B
ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE
27°c DB / 19°c WB 20°c DB
7°c50°c (2 PIPES SYSTEM)
12°c
70°c (4 PIPES SYSTEM)
ENTERING AIR TEMPRATURE
MODE COOLING HEATING
60°c (4 PIPES SYSTEM)
ENTERING WATER TEMPRATURE
LEAVING WATER TEMPRATURE
27
Features:• Cool/Heat/Fan/Dry/Auto mode• Auto/High/Med/Low fan speed• Temperature operate in ºC and ºF• Turbo and Quiet Function• Sleep function• Swing function• Real time clock and day display• 7-days programmable timer• Error indicator• Key lock and fan lock features• Batteries backup and retain setting during power failure• Last state memory (Memory backup setting from main board)• Delay Timer (1 or 2 hours)• Interaction with Wireless Handset (BRC52A61/BRC52A62)
1. Vertical Automatic Air Swing2. Selectable Mode: Auto Mode, Cooling , Heating, Dry, Fan3. Turbo Function4. Quiet Function5. ON Timer Setting6. Real Time Clock7. Transmission Source8. “Glow in the dark” ON/OFF Button9. Fan Speed Selection: Low, Med, High, Auto10. Temperature Setting: Up & Down11. Sleep Mode Function12. OFF Timer Setting
1
7
8
9
101112
234
5
6
BRC52A61 – Heatpump with auto modeBRC52A62 – Cooling onlyBRC52A63 - Heatpump
BRC51A61 – Heatpump with auto modeBRC51A62 – Cooling only
ControllerBRC52A
BRC51A
28
With Wireless Remote Controller
With Wired Remote Controller
CONTROLLER
Power from Indoor
Power from Outdoor
POWER SUPPLY
Selectable Fan Speed - Di�erent fan speed isavailable for comfort selection
Belt Driven Evaporator Motor
Automatic Vertical Swing - Automatic movementof air discharge louver for uniform air distribution
Manual Horizontal Air Flow - Adjustable horizontaldischarge grille for desired air �ow direction
AIR FLOW
4 Way Air Discharge
Standard FeaturesCOMFORT
Dry Mode - Keeping the room dehumidi�ed,while maintaining room temperature
Turbo Mode - Rapid cooling/heating withhighest fan speed for immediate comfort
Quiet Mode - E�ective cooling withlower noise level
Auto Mode - Auto switching between cooling andheating mode depending on room and set temperature
Sleep Mode
FIN TYPE
Bare Aluminium FinAL
Anti Corrosion Hydrophilic Gold FinGOLD
Ionizer
IAQWashable Saranet Filter - Removal of airborne dustparticles through saranet �lter ensures cleaner airsupply
Titanium Apatite Photocatalytic Air-Purifying Filter
Bio Antibody Filter
Variable Pitch Pully Drive Package
29
NIM
Main Board Controllers And Display Control PanelNIM must be used in conjunction with:• Fan coil units • BRC51A or BRC52A
Network Interface Module (NIM) is a networking system which enables communication among Daikin air conditioners.With the Network Interface Module (NIM), all your air conditioning systems can be controlled with just a single controller giving you benefits:
Benefits• More convenience. No more individually controlling air conditioning units• Quicker and easier zone control from the master control unit• Better control of air conditioning systems operating conditionsNIM utilizes master-slave type system whereby the master node will issue commands to each of the slave nodes.
Every master unit will have a group address so that every slave can only response to their respective master. Each slave unit must have a unique address so that it can be addressed independently of other nodes.
The master unit will be operating in conjunction with a control panel. Any settings done via the control panel connected to the master will overwrite the settings of its slave units.
Slave unit can be operated with or without control panel. If a slave unit is operating with a control panel, its settings can be changed without following its master.
Basic Features• DIP switch setting for Group & Unit address.• Master or slave system configuration.• Automatic detection of control panel existence.• Error type and unit ID indication through display control panel.
• Maximum point to point communication bus up to 1000m.• A single master unit can control up to 15 slave units in each group.• Each slave unit will sense their individual local temperature.• Unit address range from 0 to 15 (0000-1111).
The NIM System Consists Of• Main Board controller • Display control panel • NIM controller • Communications bus
Intelligent Control Series
Network Control NIM
(up to total of16 FCUs)
Slave(s)Slave(s)SlaveMaster
Connection
ConnectionThe communication bus must be connected serially to the adjacent NIM. (Daisy chain connection). The same polarity has to be connected between the NIMs (A to A, B to B).
Communication BusA 2-way twisted pair cable is used as the communication bus. Recommended cable for communication bus is a pair of screened & shielded, twisted single core wire with core diameter of 0.5mm to 1.0mm.
Supported Configuration
BRC51A
BRC52A
Master Slave
G-Way
First NIM to the furthestconnected NIM 1000
10
10
Connection
NIM to Main Board
NIM to Wired Controller
Recommended Maximum Cable Length (m)
G-Way
To MainBoard
To Wired Control Panel
CN2
CN1 RELAY 1
RELAY 2
DIP SwitchTerminal
Blocks
NO
NO
COM
COM
Dry ContactOutput 1
Dry ContactInput
Dry ContactSwitch
Unit On/OffIndicator
Unit ErrorIndicator
BMSG-Way Controller
Dry ContactOutput 2
1000 m
Types of Operation DSW2 Setting
Control & Monitor (Ext. Switch Closed = ON A/C) 0000
0010
0001
Control & Monitor (Ext. Switch Open = ON A/C)
Monitoring only
Function• Gateway between DX fan coil unit and basic Building Management System (BMS).
Note: • Remote (On/Off) control of air conditioner via BMS.• Unit error indication via BMS and BRC51A controller.• Unit operation status monitoring via BMS.• Maximum point to point communication bus between air conditioner and BMS of up to 1000m.• DIP switch setting for control or monitoring function.
DSW2 Setting
30 31
• Laboratory• Railway Switching Center• Room with Critical Electronics Equipments
• S-NIM controller• Communication Bus
S-NIM
Master Unit
Slave Unit
Typical connection structure for S-NIM
Main Board Main Board
Control Panel
The S-NIM System Consists Of• Main Board controller• BRC51A
Communication BusA 2-way twisted pair cable is used as the communication bus.Recommended cable for communication bus is a pair of screened & shielded, twisted single core wire with core diameterof 0.5mm to 1.0mm.
S-NIM Controller Application• Server Room• Telecommunication Tower• Livestock Breeding Farm• Warehouse
S-NIM For Timer Switchover Control
Built on the NIM configuration, S-NIM serves to enhance the abilities and extend the operating lifetime of existing air conditioning units in harsh and demanding environment.
S-NIM works in a master & slave system, operating at alternate sequence of preset hours. Whenever the operating unit is at fault, the standby unit will automatically takes over.
Features• Auto restart feature with last state settings.• 2 air conditioning units in a master & slave system, operating at alternate sequence of preset time (3/4/5/7/9/11/12 hours).• System controlled by a single BRC51A controller.• When the operating unit is at fault, the standby unit automatically takes over.• Error indication via error code displayed on LCD panel. (only is using Netware 3 control panel)• During system OFF mode, running timer will stop. It resumes when changing to ON mode.• Preset operation hours can be set via DIP Switch.* The air conditioning unit connected to the wired controller is always the master unit.
S-NIMS-NIM
32
0. pgCover Chilled Water System1. Contentsp. 1 & 2 Applicationp. 3 & 4 Applicationp. 5 & 6 Features 1p. 7 & 8 Features 2p. 9 & 10 SPEC 1p. 11 & 12 SPEC 2p. 13 & 14 Solution 1p. 15 & 16 Solution 2p. 17 & 18 Solution 3p. 19 & 20 FCU spec 1p. 21 & 22 FCU spec 2p. 23 & 24 FCU specp. 25 & 26 FCU specp. 27 FCU specp. 28 controllerp. 29 Std featuresp. 30 & 31 NIMp. 32 NIM