Appl. and Eval of ASHRAE Standards 117 and 32.1 · PDF fileThe Department of Energy study on refrigeration focused on three common appliances. ... ASHRAE 117 – 20021 and with canned

  • Upload
    doanbao

  • View
    218

  • Download
    0

Embed Size (px)

Citation preview

  • Application and Evaluation of ASHRAE 117 2002 and ASHRAE 32.1 1997

    FSTC Report # 5011.04.01

    Food Service Technology Center Report, March 2004

    Prepared by: David Cowen

    David Zabrowski

    Fisher-Nickel, Inc.

    Contributor: Angelo Karas Scott Miner

    Fisher-Nickel, Inc.

    2004 by Fisher-Nickel, inc. All rights reserved.

    The information in this report is based on data generated at the Food Service Technology Center.

  • Acknowledgments

    A National Advisory Group provides guidance to the Food Service Technology Center Project. Members include:

    Applebees International Group

    California Energy Commission (CEC)

    California Restaurant Association

    Dennys Corporation

    DJ Horton & Associates

    Enbridge Gas Distribution

    EPA Energy Star

    Gas Technology Institute (GTI)

    Lawrence Berkeley National Laboratories

    National Restaurant Association

    Pacific Gas and Electric Company

    Safeway, Inc.

    Southern California Edison

    Underwriters Laboratories (UL)

    University of California at Berkeley

    University of California at Riverside

    US Department of Energy, FEMP

    Specific appreciation is extended to the Department of Energy and Navigant Consulting Inc., for supplying the Food Service Technology Center with a single-door reach-in freezer, 2-door reach-in beverage merchandiser and a beverage vending machine for controlled testing in the appliance laboratory.

    Policy on the Use of Food Service Technology Center Test Results and Other Related Information

    Fisher-Nickel, inc. and the Food Service Technology Center

    (FSTC) do not endorse particular products or services from any specific manufacturer or service provider.

    The FSTC is strongly committed to testing food service equipment using the best available scientific techniques and instrumentation.

    The FSTC is neutral as to fuel and energy source. It does not, in any way, encourage or promote the use of any fuel or en-ergy source nor does it endorse any of the equipment tested at the FSTC.

    FSTC test results are made available to the general public through technical research reports and publications and are protected under U.S. and international copyright laws.

    In the event that FSTC data are to be reported, quoted, or referred to in any way in publications, papers, brochures, ad-vertising, or any other publicly available documents, the rules of copyright must be strictly followed, including written per-mission from Fisher-Nickel, inc. in advance and proper attribu-tion to Fisher-Nickel, inc. and the Food Service Technology Center. In any such publication, sufficient text must be ex-cerpted or quoted so as to give full and fair representation of findings as reported in the original documentation from FSTC.

    Legal Notice

    "This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government, nor any agency thereof, nor any of their employees, nor any of their contractors, subcontractors, or their employees, makes any warranty, express or implied, or assumes any legal liability or responsibil-ity for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any spe-cific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise, does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Gov-ernment or any agency, contractor or subcontractor thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof."

  • Contents

    5011.04.01 i Food Service Technology Center

    Page Executive Summary ............................................................................... iv 1 Introduction Background ................................................................................. 1-1 Objectives and Scope.................................................................. 1-2 2 Reach-In Freezer Appliance Description ................................................................. 2-1 Setup and Instrumentation ......................................................... 2-2 Test Procedure and Results ........................................................ 2-4 3 Reach-In Beverage Merchandiser Appliance Description ................................................................. 3-1 Setup and Instrumentation ......................................................... 3-2 Test Procedure and Results ........................................................ 3-7 4 Beverage Vending Machine Appliance Description ................................................................. 4-1 Setup and Instrumentation ......................................................... 4-2 Test Procedure and Results ........................................................ 4-4 5 Conclusions .................................................................................... 5-1 6 References ....................................................................................... 6-1 Appendix A: Glossary Appendix B: Appliance Specifications Appendix C: Individual Test Data

  • List of Figures and Tables

    5011.04.01 ii Food Service Technology Center

    Page 1-1 True T-23F Reach-In Freezer ........................................................ 1-2 1-2 True GDM-49 Reach-In Beverage Merchandiser .......................... 1-3 1-3 Royal Vendors Beverage Vending Machine .................................. 1-3 2-1 True T-23F Reach-In Freezer ........................................................ 2-1 2-2 Test Simulator with Thermocouple ................................................ 2-2 2-3 Test Simulator Placement for Reach-In Freezer............................. 2-3 2-4 Reach-In Freezer Loaded with Test Simulator and Wood Filler. . 2-3 2-5 Test A, 24-hour Individual Test Simulator Temperatures ............... 2-5 2-6 Test D, 24-hour Individual Test Simulator Temperatures .............. 2-6 2-7 Total Energy Consumption Comparison ........................................ 2-8 3-1 Vinyl Coated Adjustable Wire Shelves ........................................... 3-1 3-2 True GDM-49 Reach-In Beverage Merchandiser .......................... 3-1 3-3 Test Simulator with Thermocouple ................................................ 3-3 3-4 Canned Beverage Test Simulator with Thermocouple ................... 3-3 3-5 Welded Thermocouple ................................................................... 3-3 3-6 Test Simulator Placement for Beverage Merchandiser .................. 3-4 3-7 Test Simulators and Wood Filler Material ...................................... 3-5 3-8 Canned Beverage Test Simulators and Filler Material ................... 3-6 3-9 Test A, 24-hour Individual Glycol Test Simulator Temperatures .... 3-8 3-10 Beverage Merchandiser with Shelves Loaded ............................... 3-9 3-11 Test B, 24-hour Individual Beverage Test Simulator Temperatures 3-9 3-12 Beverage Merchandiser Loaded During Recovery Test ................ 3-13 3-13 Beverage Merchandiser Recovery Test ......................................... 3-15 4-1 Royal Vendors Beverage Vending Machine .................................. 4-1 4-2 Product Storage Stacks ................................................................. 4-2 4-3 Canned Beverage Test Simulator with Thermocouple ................... 4-2 4-4 Welded Thermocouple ................................................................... 4-2 4-5 Test Simulator Location and Configuration .................................... 4-3

    Figures

  • List of Figures and Tables

    5011.04.01 iii Food Service Technology Center

    4-6 Test A, 24-hour Individual Test Simulator Temperatures ............... 4-5 4-7 Vending Machine Average Energy Rate Comparison .................... 4-7 4-8 Recover Test B Temperature Profile ............................................. 4-10 4-9 Recover Test D Temperature Profile ............................................. 4-11

    Page 2-1 Appliance Specifications ................................................................ 2-1 2-2 Reach-In Freezer Ambient Test Conditions ................................... 2-4 2-3 Reach-In Freezer Energy Consumption Test Results .................... 2-7 2-4 Reach-In Freezer 24-Hour Temperature Performance. .................. 2-9 3-1 Appliance Specifications ................................................................ 3-2 3-2 Beverage Merchandiser Ambient Test Conditions ......................... 3-7 3-3 Beverage Merchandiser Energy Consumption Test Results .......... 3-11 3-4 Beverage Merchandiser 24-Hour Temperature Performance. ........ 3-12 3-5 Beverage Merchandiser Recovery Test Results............................. 3-14 4-1 Appliance Specifications ................................................................ 4-1 4-2 Vending Machine Test Conditions ................................................. 4-4 4-3 Vending Machine Energy Consumption Test Results .................... 4-6 4-4 Vending Machine 24-Hour Temperature Performance. .................. 4-7 4-5 Recovery Test Energy Consumption Results ................................ 4-9 4-6 Sold-Out Recovery Test Results .................................................... 4-11

    Tables

  • Executive Summary

    5011.04.01 iv Food Service Technology Center

    The Department of Energy study on refrigeration focused on three common appliances. A sin