Number of Primary Samples: Number of Triplicate Samples:

Number of Duplicate Samples: Number of Other QAQC Samples:

Sample volumes sufficient for QC analysis?

Type

MB Method Blank

Analyte Group Analyte(s) Sample ID

Analyte Group Primary ID Duplicate ID

BP91_06.00_01/09/14/ QC100_01/09/14BP72_03.00_01/09/14/ QC101_01/09/14/

Analyte Group Primary ID Triplicate ID

BP91_06.00_01/09/14/ QC200_01/09/14

Analyte Group Analyte(s)

VOC Surrogates Toluene D-8

Note: Data validation assesses each analyte in terms of all the data validation variables and only the exceedances and outliers are reported in this form.

*When concentrations are less than the LOR for both primary and duplicate/triplicate results, no RPDs are calculated

Performed By: Philippe Koenig Checked By Fabiana Quinton

Date: 28/10/2014 Date: 3/11/2014

DATA VALIDATION SUMMARY SHEET (Sydney)

Project Name: Orica September Quarterly 2014 Project Number: 147623068

Date Sampled: 1 & 3 September 2014 Sample Medium: Water

Sample Information

46 1

Primary Laboratory: ALS Workorder Number: ES1419986

Secondary Laboratory: ELS Workorder Number: 116171

COC completed properly? Y Yes. Signed by both field and laboratory personnel.All requested analysis completed? Y Yes. All.

2 0

Documentation and Sample Handling Information

Y/N Comments

Y Yes.Are there non-NATA accredited methods used? N No.Laboratory reports signed by authorised personnel? Y Yes. All.

Samples received intact and chilled? Y ALS: '1.8'C - ice present, intact.' ELS: 'Cool, with ice, intact.'Samples analysed within appropriate holding times? Y Yes. All.

Trip Spike Information

Analyte Spike Concentrations Recovery Concentration %

RecoveryComments

QAQC Sample Information (Method Blank - MB, Rinsate Blank - RB, Field Blank - FB, Trip Blank - TB)

Sample ID CommentsAll results are below the LOR. (ALS & ELS).

Halogenated Aliphatic Compounds LCS recovery of 1.1.1.2-Tetrachloroethane (119%) is equal to the upper quality objective (119%). See comments. (ALS).

Matrix Spike (MS) Analyses

Analyte Group Comments

No TS was prepared in this batch.

Laboratory Control Spike (LCS) Analyses

Analyte Group Comments

CommentsAll RPDs are within the quality objectives.All RPDs are within the quality objectives.

Halogenated Aliphatic Compounds MS recovery of Trichloroethene not determined. See comments.

Laboratory Duplicates (LD) Analyses

Comments

This batch has been validated and is considered suitable for environmental interpretive use.

All other LCS recoveries are within the laboratory based quality objectives. (ALS & ELS).

All other MS recoveries are within the laboratory based quality objectives. MS analyses were undertaken on Orica samples. (ALS). ELS

did not undertake MS analyses.

MS recovery of trichloroethene not determined as the background level was greater than or equal to 4x spike level.

All other surrogate recoveries are within the laboratory based quality objectives. (ALS & ELS).

Surrogate recovery of toluene-D8 was greater than the upper quality objective. This is not expected to affect the validity of these results as exceedence is equal to the upper laboratory quality objective.

Surrogate recovery of toluene-D8 in sample BP07_10.00_01/09/14 was equal (127%) to the upper quality objective (127%). See

comments.

Overall Comments

As stated by ALS: 'EP074WF:Particular samples required dilution due to the presence of high level contaminants. LOR values have been adjusted accordingly.'

LCS recovery of 1.1.1.2-Tetrachloroethane (119%) is equal to the upper quality objective (119%). This is not expected to affect the validity of these results as exceedence is equal to the upper laboratory quality

objective.

Field Triplicates (FT) Analyses

CommentsAll RPDs are within the quality objectives.

Surrogate Compound Monitoring Analyses

Comments

All LD RPDs are within the laboratory based quality objectives. LD analyses were undertaken on Orica

samples.

Field Duplicates (FD) Analyses

Page 3: APPENDIX C - Orica

Duplicate Analysis RPDs Sample ID BP91_06.00_01/09/14 QC100_01/09/14 QC200_01/09/14

Project No. : 147623068 Sample Type Primary Field Duplicate Field Triplicate

Batch/es: ES1419986, 116171 Date Sampled 1/09/2014 1/09/2014 1/09/2014

Analyte Units LOR Primary vs Duplicate Primary vs Inter Duplicate

Carbon disulfide µg/L 1 <1 <1 - ND -

1.2-Dibromoethane (EDB) µg/L 1 <1 <1 - ND -

Dichlorodifluoromethane µg/L 10 <10 <10 - ND -

Chloromethane µg/L 10 <10 <10 <10 ND ND

Vinyl chloride µg/L 10 <10.0 <10.0 <10 ND ND

Bromomethane µg/L 10 <10 <10 - ND -

Chloroethane µg/L 10 <10 <10 <10 ND ND

Trichlorofluoromethane µg/L 10 <10 <10 - ND -

1.1-Dichloroethene µg/L 1 6 5 - 18.18% -

Iodomethane µg/L 1 <1 <1 - ND -

Methylene chloride µg/L 5 <5 <5 <10 ND ND

trans-1.2-Dichloroethene µg/L 1 <1 1 1 ND ND

1.1-Dichloroethane µg/L 1 1 1 2 0.00% 66.67%

cis-1.2-Dichloroethene µg/L 1 2 2 2 0.00% 0.00%

1.1.1-Trichloroethane µg/L 1 <1 <1 <1 ND ND

1.1-Dichloropropylene µg/L 1 <1 <1 - ND -

Carbon Tetrachloride µg/L 1 <1 <1 <1 ND ND

1.2-Dichloroethane µg/L 1 4 3 3 28.57% 28.57%

Trichloroethene µg/L 1 111 100 120 10.43% 7.79%

Dibromomethane µg/L 1 <1 <1 - ND -

1.1.2-Trichloroethane µg/L 1 148 131 150 12.19% 1.34%

1.3-Dichloropropane µg/L 1 <1 <1 - ND -

Tetrachloroethene µg/L 1 243 208 270 15.52% 10.53%

1.1.1.2-Tetrachloroethane µg/L 1 1 <1 1 ND 0.00%

trans-1.4-Dichloro-2-butene µg/L 1 <1 <1 - ND -

cis-1.4-Dichloro-2-butene µg/L 1 <1 <1 - ND -

1.1.2.2-Tetrachloroethane µg/L 1 94 94 120 0.00% 24.30%

1.2.3-Trichloropropane µg/L 1 <1 1 - ND -

Pentachloroethane µg/L 1 <1 <1 - ND -

1.2-Dibromo-3-chloropropane µg/L 1 <1 <1 - ND -

Hexachlorobutadiene µg/L 1 <1.0 <1.0 - ND -

Vinyl chloride µg/L 1 - - -

Chloroform µg/L 1 9 9 11 0.00% 20.00%

Bromodichloromethane µg/L 1 <1 <1 - ND -

Dibromochloromethane µg/L 1 <1 <1 - ND -

Bromoform µg/L 1 <1 <1 - ND -

Legend

ND = Not Detected (RPDs not calculated if both primary and duplicate results are below LOR)

- = Not analysed/calculated

Acceptable RPDs: RPD <= 30%

RPD > 30%, Analyis result < 10 times LOR

RPD <= 50%, Analysis result > 10 times LOR and < 20 times LOR

Project: Orica September 2014 Annual

RPDs

Page 4: APPENDIX C - Orica

Duplicate Analysis RPDs Sample ID BP72_03.00_01/09/14/ QC101_01/09/14/

Project No. : 147623068 Sample Type Primary Field Duplicate

Batch/es: ES1419986 Date Sampled 1/09/2014 1/09/2014

RPDs

Analyte Units LOR Primary vs Duplicate

Carbon disulfide µg/L 1 <1 <1 ND

1.2-Dibromoethane (EDB) µg/L 1 <1 <1 ND

Dichlorodifluoromethane µg/L 10 <10 <10 ND

Chloromethane µg/L 10 <10 <10 ND

Vinyl chloride µg/L 10 <10.0 <10.0 ND

Bromomethane µg/L 10 <10 <10 ND

Chloroethane µg/L 10 <10 <10 ND

Trichlorofluoromethane µg/L 10 <10 <10 ND

1.1-Dichloroethene µg/L 1 <1 <1 ND

Iodomethane µg/L 1 <1 <1 ND

Methylene chloride µg/L 5 <5 <5 ND

trans-1.2-Dichloroethene µg/L 1 <1 <1 ND

1.1-Dichloroethane µg/L 1 <1 <1 ND

cis-1.2-Dichloroethene µg/L 1 <1 <1 ND

1.1.1-Trichloroethane µg/L 1 <1 <1 ND

1.1-Dichloropropylene µg/L 1 <1 <1 ND

Carbon Tetrachloride µg/L 1 <1 <1 ND

1.2-Dichloroethane µg/L 1 13 14 7.41%

Trichloroethene µg/L 1 <1 <1 ND

Dibromomethane µg/L 1 <1 <1 ND

1.1.2-Trichloroethane µg/L 1 <1 <1 ND

1.3-Dichloropropane µg/L 1 <1 <1 ND

Tetrachloroethene µg/L 1 <1 <1 ND

1.1.1.2-Tetrachloroethane µg/L 1 <1 <1 ND

trans-1.4-Dichloro-2-butene µg/L 1 <1 <1 ND

cis-1.4-Dichloro-2-butene µg/L 1 <1 <1 ND

1.1.2.2-Tetrachloroethane µg/L 1 <1 <1 ND

1.2.3-Trichloropropane µg/L 1 <1 <1 ND

Pentachloroethane µg/L 1 <1 <1 ND

1.2-Dibromo-3-chloropropane µg/L 1 <1 <1 ND

Hexachlorobutadiene µg/L 1 <1.0 <1.0 ND

Vinyl chloride µg/L 1 <1 - ND

Chloroform µg/L 1 <1 <1 ND

Bromodichloromethane µg/L 1 <1 <1 ND

Dibromochloromethane µg/L 1 <1 <1 ND

Bromoform µg/L 1 <1 <1 ND

Legend

ND = Not Detected (RPDs not calculated if both primary and duplicate results are below LOR)

- = Not analysed/calculated

Acceptable RPDs: RPD <= 30%

RPD > 30%, Analyis result < 10 times LOR

RPD <= 50%, Analysis result > 10 times LOR and < 20 times LOR

Project: Orica September 2014 Annual

Page 5: APPENDIX C - Orica

Number of Primary Samples: Number of Triplicate Samples:

Number of Duplicate Samples: Number of Other QAQC Samples:

Sample volumes sufficient for QC analysis?

Type

MB Method BlankTB Trip Blank

Analyte Group Analyte(s) Sample ID

Analyte Group Primary ID Duplicate ID

Analyte Group Primary ID Triplicate ID

Analyte Group Analyte(s)

Note: Data validation assesses each analyte in terms of all the data validation variables and only the exceedances and outliers are reported in this form.

*When concentrations are less than the LOR for both primary and duplicate/triplicate results, no RPDs are calculated

Performed By: Philippe Koenig Checked By Fabiana Quinton

Date: 28/10/2014 Date: 3/11/2014

Field Triplicates (FT) Analyses

CommentsNo FTs were prepared in this batch.

This batch has been validated and is considered suitable for environmental interpretive use.

Overall Comments

As stated by ALS: 'EP074-WF: Various samples required dilution due to the presence of high level contaminants. LOR values have been adjusted accordingly.'

As stated by ALS: 'VC SIM added to BP65_L_0.5_05/09/14 as per Luke, 12/9/14.'

Security seal noted as 'not-intact'. This is because samples were delivered to the laboratory by Ivan Ward and directly handed to lab staff.

As stated by ALS: 'Sample BP64_L_0.1_05/09/14 was received extra and placed on hold. Analyse for VCH and VC SIM as per Luke 12/9/14'

As stated by ALS: 'Sample BP01_12.00_05/09/14 was received as BP01_10.00_05/09/14 on the bottles; lab will follow ID from the bottles. Confirmed by Luke, 12/9/14.'

All LD RPDs are within the laboratory based quality objectives. LD analyses undertaken on Orica samples

Field Duplicates (FD) Analyses

CommentsNo FDs were prepared in this batch.

Surrogate Compound Monitoring Analyses

CommentsAll surrogate recoveries are within the laboratory based quality objectives.

Matrix Spike (MS) Analyses

Analyte Group CommentsAll MS recoveries are within the laboratory based quality objectives. MS analyses undertaken on Orica samples.

Laboratory Duplicates (LD) Analyses

Comments

No TS was prepared in this batch.

Laboratory Control Spike (LCS) Analyses

Analyte Group CommentsAll LCS recoveries are within the laboratory based quality objectives.

All results are below the LOR.All results are below the LOR.

Trip Spike Information

Analyte Spike Concentrations Recovery Concentration %

RecoveryComments

Laboratory reports signed by authorised personnel? Y Yes. All.

QAQC Sample Information (Method Blank - MB, Rinsate Blank - RB, Field Blank - FB, Trip Blank - TB)

Sample ID Comments

Y Yes.Are there non-NATA accredited methods used? N No.

Samples analysed within appropriate holding times? Y Yes. All.

COC completed properly? Y Yes. Signed by both field and laboratory personnel.All requested analysis completed? Y Yes. All.

Date Sampled: 5 & 8 September 2014 Sample Medium: Water

Sample Information

46 0

Samples received intact and chilled? N ALS: '0.6'C - ice present, not intact.' See comments.

0 1

Documentation and Sample Handling Information

Y/N Comments

Primary Laboratory: ALS Workorder Number: ES1420325

Secondary Laboratory: - Workorder Number: -

DATA VALIDATION SUMMARY SHEET (Sydney)

Project Name: Orica September Quarterly 2014 Project Number: 147623068

Page 6: APPENDIX C - Orica

Number of Primary Samples: Number of Triplicate Samples:

Number of Duplicate Samples: Number of Other QAQC Samples:

Sample volumes sufficient for QC analysis?

Type

MB Method BlankTB TB_11/09/14TB TB_12/09/14

Analyte Group Analyte(s) Sample ID

Analyte Group Primary ID Duplicate IDBP80_06.00_10/09/14 QC102_10/09/14BP80_15.00_10/09/14 QC103_10/09/14BP114_10.00_10/09/14 QC104_10/09/14WG23S_10/09/14 QC105_10/09/14BP62_04.00_10/09/14 QC106_10/09/14WG234S_10/09/14 QC107_10/09/14BP89_18.00_11/09/14 QC108_11/09/14BP76_04.00_12/09/14 QC109_12/09/14BP76_10.00_12/09/14 QC110_12/09/14BP55_06.00_12/09/14 QC111_12/09/14BP60_04.00_12/09/14 QC112_12/09/14

BP60_28.00_12/09/14 QC113_12/09/14

WG154S_12/09/14 QC114_12/09/14WG231S_12/09/14 QC115_12/09/14

Analyte Group Primary ID Triplicate IDBP80_06.00_10/09/14 QC202_10/09/14BP114_10.00_10/09/14 QC204_10/09/14BP62_04.00_10/09/14 QC206_10/09/14BP89_18.00_11/09/14 QC208_11/09/14BP76_10.00_12/09/14 QC210_12/09/14

BP60_04.00_12/09/14 QC212_12/09/14

WG154S_12/09/14 QC214_12/09/14

Analyte Group Analyte(s)

Note: Data validation assesses each analyte in terms of all the data validation variables and only the exceedances and outliers are reported in this form.

*When concentrations are less than the LOR for both primary and duplicate/triplicate results, no RPDs are calculated

Performed By: Philippe Koenig Checked By Fabiana Quinton

Date: 17/10/2014 Date: 3/11/2014

All other surrogate recoveries are within laboratory based quality objectives. (ALS & ELS).

BP60 samples mislabbeled from the 6 m and 26 m sample port. Corrected for interpretation.

This batch has been validated and is considered suitable for environmental interpretive use.

Overall Comments

As stated by ALS: 'Benzo(a)pyrene Toxicity Equivalent Quotient (TEQ) is the sum total of the concentration of the eight carcinogenic PAHs multiplied by their Toxicity Equivalence Factor (TEF) relative to Benzo(a)pyrene.

TEF values are provided in brackets as follows: Benz(a)anthracene (0.1), Chrysene (0.01), Benzo(b+j) & Benzo(k)fluoranthene (0.1), Benzo(a)pyrene (1.0), Indeno(1.2.3.cd)pyrene (0.1), Dibenz(a.h)anthracene (1.0),

Benzo(g.h.i)perylene (0.01). Less than LOR results for 'TEQ Zero' are treated as zero. EP074-WF: Particular samples required dilution due to the presence of high level contaminants. LOR values have been adjusted

accordingly. EP074WF: Results of QC113_12/09/14 have been confirmed by re-analysis. l EP075: 'Sum of PAH' is the sum of the USEPA 16 priority PAHs.'

LCS recovery of vinyl chloride was greater (125%) than the upper quality control limit (123%). This is not expected to affect the validity of these results as exceedence from acceptable criteria is marginal (2%).

Furthermore, MS and surrogate recoveries for vinyl chloride are within quality objectives.

MS recovery of 1.1-dichloroethene and trichloroethene not determined in sample BP60_06.00_12/09/14, background level greater than or equal to 4x spike level.

FD RPDs of cis-1.2-dichloroethene and chloroform of primary sample BP60_28.00_12/09/14 are outside of quality objectives. This is not expected to affect the validity of these results, as LCS, MS, Surrogate and other

FD/FT RPDs of this analyte are within quality objectives. As a conservative measure, the highest value will be adopted for interpretative purposes.

Surrogate recovey of toluene-D8 in samples BP114_06.00_10/09/14, BP114_20.00_10/09/14, WG234I_10/09/14 & BP89_12.00_11/09/14 is equal (127%) to the data quality objective (127%). This is not expected to

affect the validity of these results.

FT RPD of 1.2-dichloroethane of primary sample BP60_04.00_12/09/14 is outside of quality objectives. This may be due to different techniquesused for the two laboratories and is not expected to affect the quality of

this data. As a conservative measure, the highest value will be adopted for interpretative purposes.

Field Triplicates (FT) Analyses

CommentsAll RPDs are within quality objectives.

All RPDs are within quality objectives.

RPD of 1.2-Dichloroethane (190%) is outside of quality objectives. All other RPDs are within quality

objectives.

Recovery of toluene-D8 in sample BP114_20.00_10/09/14 equal (127%) to the upper data quality objective (127%). See comments.

RPDs of cis-1.2-Dichloroethene (54.55%) and chloroform (35.29%) are outside of quality objectives. All other

RPDs are within quality objectives.All RPDs are within quality objectives.All RPDs are within quality objectives.

All RPDs are within quality objectives.All RPDs are within quality objectives.All RPDs are within quality objectives.All RPDs are within quality objectives.

Surrogate Compound Monitoring Analyses

Comments

Recovery of toluene-D8 in sample BP114_06.00_10/09/14 equal (127%) to the upper data quality objective (127%). See comments.

VOC surrogates Toluene-D8

Recovery of toluene-D8 in sample WG234I_10/09/14 equal (127%) to the upper data quality objective (127%). See comments.

Recovery of toluene-D8 in sample BP89_12.00_11/09/14 equal (127%) to the upper data quality objective (127%). See comments.

All LD RPDs are within laboratory based quality objectives. LD performed on Orica samples(ALS & ELS).

Field Duplicates (FD) Analyses

CommentsAll RPDs are within quality objectives.

All other MS recoveries are within laboratory based quality objectives. MS conducted on Orica samples (ALS). ELS did not conduct MS

analyses as a part of these batches.

Laboratory Duplicates (LD) Analyses

Comments

Halogenated Aliphatic CompoundsRecovery of 1.1-Dichloroethene and trichloroethene not determined in sample BP60_06.00_12/09/14. See comments. (ALS).

Laboratory Control Spike (LCS) Analyses

Analyte Group CommentsHalogenated Aliphatic Compounds Recovery of vinyl chloride was greater (125%) than the upper quality control limit (123%). See comments. (ALS)

All other LCS recoveries are within laboratory based quality objectives. (ALS & ELS).

No TS was prepared in this batch.

Matrix Spike (MS) Analyses

Analyte Group Comments

All results below the LOR. (ALS & ELS).All results below the LOR. (ALS)All results below the LOR. (ALS)

Trip Spike Information

Analyte Spike Concentrations Recovery Concentration % Recovery Comments

Laboratory reports signed by authorised personnel? Y Yes. All.

QAQC Sample Information (Method Blank - MB, Rinsate Blank - RB, Field Blank - FB, Trip Blank - TB)

Sample ID Comments

Y Yes.Are there non-NATA accredited methods used? N No.

Samples received intact and chilled? Y ALS: '2.6'C - Ice present. Intact.' ELS: '6.5'C with ice.'Samples analysed within appropriate holding times? Y ALS: 'sample(s) have been received within the recommended holding times.'

COC completed properly? Y Yes. Signed by field and laboratory personnel.All requested analysis completed? Y Yes. All.

14 2

Documentation and Sample Handling Information

Y/N Comments

Date Sampled: 10, 11 & 12 September 2014 Sample Medium: Water

Sample Information

59 7

Primary Laboratory: ALS Workorder Number: ES1420737

Secondary Laboratory: ELS Workorder Number: 116171, 116361

DATA VALIDATION SUMMARY SHEET (Sydney)

Project Name: Orica September Quarterly 2014 Project Number: 147623068

All RPDs are within quality objectives.All RPDs are within quality objectives.All RPDs are within quality objectives.All RPDs are within quality objectives.All RPDs are within quality objectives.

All RPDs are within quality objectives.All RPDs are within quality objectives.All RPDs are within quality objectives.All RPDs are within quality objectives.

All RPDs are within quality objectives.

Page 7: APPENDIX C - Orica

Duplicate Analysis RPDs Sample ID BP80_06.00_10/09/14 QC102_10/09/14 QC202_10/09/14

Project No. : 147623068 Sample Type Primary Field Duplicate Field Triplicate

Batch/es: ES1420737, 116171 Date Sampled 10/09/2014 10/09/2014 10/09/2014

Analyte Units LOR Primary vs Duplicate Primary vs Inter Duplicate

Carbon disulfide µg/L 1 <1 <1 - ND -

1.2-Dibromoethane (EDB) µg/L 1 <1 <1 - ND -

Dichlorodifluoromethane µg/L 10 <10 <10 - ND -

Chloromethane µg/L 10 <10 <10 <10 ND ND

Vinyl chloride µg/L 10 <10.0 <10.0 <10 ND ND

Bromomethane µg/L 10 <10 <10 - ND -

Chloroethane µg/L 10 <10 <10 <10 ND ND

Trichlorofluoromethane µg/L 10 <10 <10 - ND -

1.1-Dichloroethene µg/L 1 <1 <1 - ND -

Iodomethane µg/L 1 <1 <1 - ND -

Methylene chloride µg/L 5 <5 <5 <10 ND ND

trans-1.2-Dichloroethene µg/L 1 1 1 1 0.00% 0.00%

1.1-Dichloroethane µg/L 1 <1 <1 <1 ND ND

cis-1.2-Dichloroethene µg/L 1 1 1 1 0.00% 0.00%

1.1.1-Trichloroethane µg/L 1 <1 <1 <1 ND ND

1.1-Dichloropropylene µg/L 1 <1 <1 - ND -

Carbon Tetrachloride µg/L 1 <1 <1 <1 ND ND

1.2-Dichloroethane µg/L 1 <1 <1 <1 ND ND

Trichloroethene µg/L 1 16 17 18 6.06% 11.76%

Dibromomethane µg/L 1 <1 <1 - ND -

1.1.2-Trichloroethane µg/L 1 50 47 47 6.19% 6.19%

1.3-Dichloropropane µg/L 1 <1 <1 - ND -

Tetrachloroethene µg/L 1 30 28 34 6.90% 12.50%

1.1.1.2-Tetrachloroethane µg/L 1 <1 <1 <1 ND ND

trans-1.4-Dichloro-2-butene µg/L 1 <1 <1 - ND -

cis-1.4-Dichloro-2-butene µg/L 1 <1 <1 - ND -

1.1.2.2-Tetrachloroethane µg/L 1 4 4 6 0.00% 40.00%

1.2.3-Trichloropropane µg/L 1 <1 <1 - ND -

Pentachloroethane µg/L 1 <1 <1 - ND -

1.2-Dibromo-3-chloropropane µg/L 1 <1 <1 - ND -

Hexachlorobutadiene µg/L 1 2.9 3.0 - 3.39% -

Vinyl chloride µg/L 1 <1 - - ND -

Chloroform µg/L 1 <1 <1 <1 ND ND

Bromodichloromethane µg/L 1 <1 <1 - ND -

Dibromochloromethane µg/L 1 <1 <1 - ND -

Bromoform µg/L 1 <1 <1 - ND -

Legend

ND = Not Detected (RPDs not calculated if both primary and duplicate results are below LOR)

- = Not analysed/calculated

Acceptable RPDs: RPD <= 30%

RPD > 30%, Analyis result < 10 times LOR

RPD <= 50%, Analysis result > 10 times LOR and < 20 times LOR

Project: Orica September 2014 Annual

RPDs

Page 8: APPENDIX C - Orica

Duplicate Analysis RPDs Sample ID BP80_15.00_10/09/14 QC103_10/09/14

Project No. : 147623068 Sample Type Primary Field Duplicate

Batch/es: ES1420737 Date Sampled 10/09/2014 10/09/2014

RPDs

Analyte Units LOR Primary vs Duplicate

Carbon disulfide µg/L 1 <1 <1 ND

1.2-Dibromoethane (EDB) µg/L 1 <1 <1 ND

Dichlorodifluoromethane µg/L 10 <10 <10 ND

Chloromethane µg/L 10 <10 <10 ND

Vinyl chloride µg/L 10 <10.0 <10.0 ND

Bromomethane µg/L 10 <10 <10 ND

Chloroethane µg/L 10 <10 <10 ND

Trichlorofluoromethane µg/L 10 <10 <10 ND

1.1-Dichloroethene µg/L 1 2 2 0.00%

Iodomethane µg/L 1 <1 <1 ND

Methylene chloride µg/L 5 <5 <5 ND

trans-1.2-Dichloroethene µg/L 1 2 2 0.00%

1.1-Dichloroethane µg/L 1 <1 <1 ND

cis-1.2-Dichloroethene µg/L 1 20 21 4.88%

1.1.1-Trichloroethane µg/L 1 <1 <1 ND

1.1-Dichloropropylene µg/L 1 <1 <1 ND

Carbon Tetrachloride µg/L 1 55 55 0.00%

1.2-Dichloroethane µg/L 1 1 1 0.00%

Trichloroethene µg/L 1 45 46 2.20%

Dibromomethane µg/L 1 <1 <1 ND

1.1.2-Trichloroethane µg/L 1 75 74 1.34%

1.3-Dichloropropane µg/L 1 <1 <1 ND

Tetrachloroethene µg/L 1 52 53 1.90%

1.1.1.2-Tetrachloroethane µg/L 1 <1 <1 ND

trans-1.4-Dichloro-2-butene µg/L 1 <1 <1 ND

cis-1.4-Dichloro-2-butene µg/L 1 <1 <1 ND

1.1.2.2-Tetrachloroethane µg/L 1 7 7 0.00%

1.2.3-Trichloropropane µg/L 1 <1 <1 ND

Pentachloroethane µg/L 1 <1 <1 ND

1.2-Dibromo-3-chloropropane µg/L 1 <1 <1 ND

Hexachlorobutadiene µg/L 1 23.4 23.6 0.85%

Chloroform µg/L 1 12 13 8.00%

Bromodichloromethane µg/L 1 <1 <1 ND

Dibromochloromethane µg/L 1 <1 <1 ND

Bromoform µg/L 1 <1 <1 ND

Legend

ND = Not Detected (RPDs not calculated if both primary and duplicate results are below LOR)

- = Not analysed/calculated

Acceptable RPDs: RPD <= 30%

RPD > 30%, Analyis result < 10 times LOR

RPD <= 50%, Analysis result > 10 times LOR and < 20 times LOR

Project: Orica September 2014 Annual

Page 9: APPENDIX C - Orica

Duplicate Analysis RPDs Sample ID BP114_10.00_10/09/14 QC104_10/09/14 QC204_10/09/14

Project No. : 147623068 Sample Type Primary Field Duplicate Field Triplicate

Batch/es: ES1420737, 116171 Date Sampled 10/09/2014 10/09/2014 10/09/2014

Analyte Units LOR Primary vs Duplicate Primary vs Inter Duplicate

Carbon disulfide µg/L 1 1 2 - 66.67% -

1.2-Dibromoethane (EDB) µg/L 1 <1 <1 - ND -

Dichlorodifluoromethane µg/L 10 <10 <10 - ND -

Chloromethane µg/L 10 <10 <10 <10 ND ND

Vinyl chloride µg/L 10 <10.0 <10.0 <10 ND ND

Bromomethane µg/L 10 <10 <10 - ND -

Chloroethane µg/L 10 <10 <10 <10 ND ND

Trichlorofluoromethane µg/L 10 <10 <10 - ND -

1.1-Dichloroethene µg/L 1 <1 <1 - ND -

Iodomethane µg/L 1 <1 <1 - ND -

Methylene chloride µg/L 5 <5 <5 <10 ND ND

trans-1.2-Dichloroethene µg/L 1 <1 <1 <1 ND ND

1.1-Dichloroethane µg/L 1 <1 <1 <1 ND ND

cis-1.2-Dichloroethene µg/L 1 2 3 4 40.00% 66.67%

1.1.1-Trichloroethane µg/L 1 <1 <1 <1 ND ND

1.1-Dichloropropylene µg/L 1 <1 <1 - ND -

Carbon Tetrachloride µg/L 1 <1 <1 <1 ND ND

1.2-Dichloroethane µg/L 1 <1 <1 <1 ND ND

Trichloroethene µg/L 1 2 2 2 0.00% 0.00%

Dibromomethane µg/L 1 <1 <1 - ND -

1.1.2-Trichloroethane µg/L 1 <1 <1 <1 ND ND

1.3-Dichloropropane µg/L 1 <1 <1 - ND -

Tetrachloroethene µg/L 1 <1 <1 <1 ND ND

1.1.1.2-Tetrachloroethane µg/L 1 <1 <1 <1 ND ND

trans-1.4-Dichloro-2-butene µg/L 1 <1 <1 - ND -

cis-1.4-Dichloro-2-butene µg/L 1 <1 <1 - ND -

1.1.2.2-Tetrachloroethane µg/L 1 <1 <1 <1 ND ND

1.2.3-Trichloropropane µg/L 1 <1 <1 - ND -

Pentachloroethane µg/L 1 <1 <1 - ND -

1.2-Dibromo-3-chloropropane µg/L 1 <1 <1 - ND -

Hexachlorobutadiene µg/L 1 <1.0 <1.0 - ND -

Vinyl chloride µg/L 1 - - - ND -

Chloroform µg/L 1 <1 <1 1 ND ND

Bromodichloromethane µg/L 1 <1 <1 - ND -

Dibromochloromethane µg/L 1 <1 <1 - ND -

Bromoform µg/L 1 <1 <1 - ND -

Legend

ND = Not Detected (RPDs not calculated if both primary and duplicate results are below LOR)

- = Not analysed/calculated

Acceptable RPDs: RPD <= 30%

RPD > 30%, Analyis result < 10 times LOR

RPD <= 50%, Analysis result > 10 times LOR and < 20 times LOR

Project: Orica September 2014 Annual

RPDs

Page 10: APPENDIX C - Orica

Duplicate Analysis RPDs Sample ID WG23S_10/09/14 QC105_10/09/14

Project No. : 147623068 Sample Type Primary Field Duplicate

Batch/es: ES1420737 Date Sampled 10/09/2014 10/09/2014

RPDs

Analyte Units LOR Primary vs Duplicate

Carbon disulfide µg/L 1 3 2 40.00%

1.2-Dibromoethane (EDB) µg/L 1 <1 <1 ND

Dichlorodifluoromethane µg/L 10 <10 <10 ND

Chloromethane µg/L 10 <10 <10 ND

Vinyl chloride µg/L 10 20.0 19.9 0.50%

Bromomethane µg/L 10 <10 <10 ND

Chloroethane µg/L 10 <10 <10 ND

Trichlorofluoromethane µg/L 10 <10 <10 ND

1.1-Dichloroethene µg/L 1 <1 <1 ND

Iodomethane µg/L 1 <1 <1 ND

Methylene chloride µg/L 5 <5 <5 ND

trans-1.2-Dichloroethene µg/L 1 9 8 11.76%

1.1-Dichloroethane µg/L 1 6 6 0.00%

cis-1.2-Dichloroethene µg/L 1 63 62 1.60%

1.1.1-Trichloroethane µg/L 1 <1 <1 ND

1.1-Dichloropropylene µg/L 1 <1 <1 ND

Carbon Tetrachloride µg/L 1 <1 <1 ND

1.2-Dichloroethane µg/L 1 2 2 0.00%

Trichloroethene µg/L 1 2 2 0.00%

Dibromomethane µg/L 1 <1 <1 ND

1.1.2-Trichloroethane µg/L 1 <1 <1 ND

1.3-Dichloropropane µg/L 1 <1 <1 ND

Tetrachloroethene µg/L 1 <1 <1 ND

1.1.1.2-Tetrachloroethane µg/L 1 <1 <1 ND

trans-1.4-Dichloro-2-butene µg/L 1 <1 <1 ND

cis-1.4-Dichloro-2-butene µg/L 1 <1 <1 ND

1.1.2.2-Tetrachloroethane µg/L 1 <1 <1 ND

1.2.3-Trichloropropane µg/L 1 <1 <1 ND

Pentachloroethane µg/L 1 <1 <1 ND

1.2-Dibromo-3-chloropropane µg/L 1 <1 <1 ND

Hexachlorobutadiene µg/L 1 1.3 1.3 0.00%

Chloroform µg/L 1 <1 <1 ND

Bromodichloromethane µg/L 1 <1 <1 ND

Dibromochloromethane µg/L 1 <1 <1 ND

Bromoform µg/L 1 <1 <1 ND

Legend

ND = Not Detected (RPDs not calculated if both primary and duplicate results are below LOR)

- = Not analysed/calculated

Acceptable RPDs: RPD <= 30%

RPD > 30%, Analyis result < 10 times LOR

RPD <= 50%, Analysis result > 10 times LOR and < 20 times LOR

Project: Orica September 2014 Annual

Page 11: APPENDIX C - Orica

Duplicate Analysis RPDs Sample ID BP62_04.00_10/09/14 QC106_10/09/14 QC206_10/09/14

Project No. : 147623068 Sample Type Primary Field Duplicate Field Triplicate

Batch/es: ES1420737, 116171 Date Sampled 10/09/2014 10/09/2014 10/09/2014

Analyte Units LOR Primary vs Duplicate Primary vs Inter Duplicate

Carbon disulfide µg/L 1 1 2 - 66.67% -

1.2-Dibromoethane (EDB) µg/L 1 <1 <1 - ND -

Dichlorodifluoromethane µg/L 10 <10 <10 - ND -

Chloromethane µg/L 10 <10 <10 <10 ND ND

Vinyl chloride µg/L 10 <10.0 <10.0 <10 ND ND

Bromomethane µg/L 10 <10 <10 - ND -

Chloroethane µg/L 10 <10 <10 <10 ND ND

Trichlorofluoromethane µg/L 10 <10 <10 - ND -

1.1-Dichloroethene µg/L 1 <1 <1 - ND -

Iodomethane µg/L 1 <1 <1 - ND -

Methylene chloride µg/L 5 <5 <5 <10 ND ND

trans-1.2-Dichloroethene µg/L 1 <1 <1 <1 ND ND

1.1-Dichloroethane µg/L 1 <1 <1 <1 ND ND

cis-1.2-Dichloroethene µg/L 1 <1 <1 <1 ND ND

1.1.1-Trichloroethane µg/L 1 <1 <1 <1 ND ND

1.1-Dichloropropylene µg/L 1 <1 <1 - ND -

Carbon Tetrachloride µg/L 1 <1 <1 <1 ND ND

1.2-Dichloroethane µg/L 1 <1 <1 <1 ND ND

Trichloroethene µg/L 1 <1 <1 <1 ND ND

Dibromomethane µg/L 1 <1 <1 - ND -

1.1.2-Trichloroethane µg/L 1 <1 <1 <1 ND ND

1.3-Dichloropropane µg/L 1 <1 <1 - ND -

Tetrachloroethene µg/L 1 <1 <1 <1 ND ND

1.1.1.2-Tetrachloroethane µg/L 1 <1 <1 <1 ND ND

trans-1.4-Dichloro-2-butene µg/L 1 <1 <1 - ND -

cis-1.4-Dichloro-2-butene µg/L 1 <1 <1 - ND -

1.1.2.2-Tetrachloroethane µg/L 1 <1 <1 <1 ND ND

1.2.3-Trichloropropane µg/L 1 <1 <1 - ND -

Pentachloroethane µg/L 1 <1 <1 - ND -

1.2-Dibromo-3-chloropropane µg/L 1 <1 <1 - ND -

Hexachlorobutadiene µg/L 1 <1.0 <1.0 - ND -

Chloroform µg/L 1 <1 <1 <1 ND ND

Bromodichloromethane µg/L 1 <1 <1 - ND -

Dibromochloromethane µg/L 1 <1 <1 - ND -

Bromoform µg/L 1 <1 <1 - ND -

Legend

ND = Not Detected (RPDs not calculated if both primary and duplicate results are below LOR)

- = Not analysed/calculated

Acceptable RPDs: RPD <= 30%

RPD > 30%, Analyis result < 10 times LOR

RPD <= 50%, Analysis result > 10 times LOR and < 20 times LOR

Project: Orica September 2014 Annual

RPDs

Page 12: APPENDIX C - Orica

Duplicate Analysis RPDs Sample ID WG234S_10/09/14 QC107_10/09/14

Project No. : 147623068 Sample Type Primary Field Duplicate

Batch/es: ES1420737 Date Sampled 10/09/2014 10/09/2014

RPDs

Analyte Units LOR Primary vs Duplicate

Carbon disulfide µg/L 1 <1 <1 ND

1.2-Dibromoethane (EDB) µg/L 1 <1 <1 ND

Dichlorodifluoromethane µg/L 10 <10 <10 ND

Chloromethane µg/L 10 <10 <10 ND

Vinyl chloride µg/L 10 11.3 10.3 9.26%

Bromomethane µg/L 10 <10 <10 ND

Chloroethane µg/L 10 <10 <10 ND

Trichlorofluoromethane µg/L 10 <10 <10 ND

1.1-Dichloroethene µg/L 1 1 1 0.00%

Iodomethane µg/L 1 <1 <1 ND

Methylene chloride µg/L 5 <5 <5 ND

trans-1.2-Dichloroethene µg/L 1 2 1 66.67%

1.1-Dichloroethane µg/L 1 1 1 0.00%

cis-1.2-Dichloroethene µg/L 1 53 46 14.14%

1.1.1-Trichloroethane µg/L 1 <1 <1 ND

1.1-Dichloropropylene µg/L 1 <1 <1 ND

Carbon Tetrachloride µg/L 1 <1 <1 ND

1.2-Dichloroethane µg/L 1 61 55 10.34%

Trichloroethene µg/L 1 2 2 0.00%

Dibromomethane µg/L 1 <1 <1 ND

1.1.2-Trichloroethane µg/L 1 <1 <1 ND

1.3-Dichloropropane µg/L 1 <1 <1 ND

Tetrachloroethene µg/L 1 <1 <1 ND

1.1.1.2-Tetrachloroethane µg/L 1 <1 <1 ND

trans-1.4-Dichloro-2-butene µg/L 1 <1 <1 ND

cis-1.4-Dichloro-2-butene µg/L 1 <1 <1 ND

1.1.2.2-Tetrachloroethane µg/L 1 <1 <1 ND

1.2.3-Trichloropropane µg/L 1 <1 <1 ND

Pentachloroethane µg/L 1 <1 <1 ND

1.2-Dibromo-3-chloropropane µg/L 1 <1 <1 ND

Hexachlorobutadiene µg/L 1 <1.0 <1.0 ND

Vinyl chloride µg/L 1 13

Chloroform µg/L 1 <1 <1 ND

Bromodichloromethane µg/L 1 <1 <1 ND

Dibromochloromethane µg/L 1 <1 <1 ND

Bromoform µg/L 1 <1 <1 ND

Legend

ND = Not Detected (RPDs not calculated if both primary and duplicate results are below LOR)

- = Not analysed/calculated

Acceptable RPDs: RPD <= 30%

RPD > 30%, Analyis result < 10 times LOR

RPD <= 50%, Analysis result > 10 times LOR and < 20 times LOR

Project: Orica September 2014 Annual

Page 13: APPENDIX C - Orica

Duplicate Analysis RPDs Sample ID BP89_18.00_11/09/14 QC108_11/09/14 QC208_11/09/14

Project No. : 147623068 Sample Type Primary Field Duplicate Field Triplicate

Batch/es: ES1420737, 116171 Date Sampled 11/09/2014 11/09/2014 11/09/2014

Analyte Units LOR Primary vs Duplicate Primary vs Inter Duplicate

Carbon disulfide µg/L 1 <1 <1 - ND -

1.2-Dibromoethane (EDB) µg/L 1 <1 <1 - ND -

Dichlorodifluoromethane µg/L 10 <10 <10 - ND -

Chloromethane µg/L 10 <10 <10 <10 ND ND

Vinyl chloride µg/L 10 28.0 34.8 49 21.66% 54.55%

Bromomethane µg/L 10 <10 <10 - ND -

Chloroethane µg/L 10 <10 <10 <10 ND ND

Trichlorofluoromethane µg/L 10 <10 <10 - ND -

1.1-Dichloroethene µg/L 1 <1 <1 - ND -

Iodomethane µg/L 1 <1 <1 - ND -

Methylene chloride µg/L 5 <5 <5 <10 ND ND

trans-1.2-Dichloroethene µg/L 1 4 4 4 0.00% 0.00%

1.1-Dichloroethane µg/L 1 2 2 2 0.00% 0.00%

cis-1.2-Dichloroethene µg/L 1 16 17 17 6.06% 6.06%

1.1.1-Trichloroethane µg/L 1 <1 <1 <1 ND ND

1.1-Dichloropropylene µg/L 1 <1 <1 - ND -

Carbon Tetrachloride µg/L 1 <1 <1 <1 ND ND

1.2-Dichloroethane µg/L 1 42 43 36 2.35% 15.38%

Trichloroethene µg/L 1 8 8 8 0.00% 0.00%

Dibromomethane µg/L 1 <1 <1 - ND -

1.1.2-Trichloroethane µg/L 1 <1 <1 <1 ND ND

1.3-Dichloropropane µg/L 1 <1 <1 - ND -

Tetrachloroethene µg/L 1 <1 <1 <1 ND ND

1.1.1.2-Tetrachloroethane µg/L 1 <1 <1 <1 ND ND

trans-1.4-Dichloro-2-butene µg/L 1 <1 <1 - ND -

cis-1.4-Dichloro-2-butene µg/L 1 <1 <1 - ND -

1.1.2.2-Tetrachloroethane µg/L 1 <1 <1 <1 ND ND

1.2.3-Trichloropropane µg/L 1 <1 <1 - ND -

Pentachloroethane µg/L 1 <1 <1 - ND -

1.2-Dibromo-3-chloropropane µg/L 1 <1 <1 - ND -

Hexachlorobutadiene µg/L 1 <1.0 <1.0 - ND -

Chloroform µg/L 1 <1 <1 <1 ND ND

Bromodichloromethane µg/L 1 <1 <1 - ND -

Dibromochloromethane µg/L 1 <1 <1 - ND -

Bromoform µg/L 1 <1 <1 - ND -

Legend

ND = Not Detected (RPDs not calculated if both primary and duplicate results are below LOR)

- = Not analysed/calculated

Acceptable RPDs: RPD <= 30%

RPD > 30%, Analyis result < 10 times LOR

RPD <= 50%, Analysis result > 10 times LOR and < 20 times LOR

Project: Orica September 2014 Annual

RPDs

Page 14: APPENDIX C - Orica

Duplicate Analysis RPDs Sample ID BP76_04.00_12/09/14 QC109_12/09/14

Project No. : 147623068 Sample Type Primary Field Duplicate

Batch/es: ES1420737 Date Sampled 12/09/2014 12/09/2014

RPDs

Analyte Units LOR Primary vs Duplicate

Carbon disulfide µg/L 1 <1 4 ND

1.2-Dibromoethane (EDB) µg/L 1 <1 <1 ND

Dichlorodifluoromethane µg/L 10 <10 <10 ND

Chloromethane µg/L 10 <10 <10 ND

Vinyl chloride µg/L 10 97.2 130 28.87%

Bromomethane µg/L 10 <10 <10 ND

Chloroethane µg/L 10 <10 <10 ND

Trichlorofluoromethane µg/L 10 <10 <10 ND

1.1-Dichloroethene µg/L 1 24 21 13.33%

Iodomethane µg/L 1 <1 <1 ND

Methylene chloride µg/L 5 <5 <5 ND

trans-1.2-Dichloroethene µg/L 1 6 4 40.00%

1.1-Dichloroethane µg/L 1 42 38 10.00%

cis-1.2-Dichloroethene µg/L 1 44 38 14.63%

1.1.1-Trichloroethane µg/L 1 <1 <1 ND

1.1-Dichloropropylene µg/L 1 <1 <1 ND

Carbon Tetrachloride µg/L 1 <1 <1 ND

1.2-Dichloroethane µg/L 1 19 20 5.13%

Trichloroethene µg/L 1 1 1 0.00%

Dibromomethane µg/L 1 <1 <1 ND

1.1.2-Trichloroethane µg/L 1 <1 <1 ND

1.3-Dichloropropane µg/L 1 <1 <1 ND

Tetrachloroethene µg/L 1 <1 <1 ND

1.1.1.2-Tetrachloroethane µg/L 1 <1 <1 ND

trans-1.4-Dichloro-2-butene µg/L 1 <1 <1 ND

cis-1.4-Dichloro-2-butene µg/L 1 <1 <1 ND

1.1.2.2-Tetrachloroethane µg/L 1 <1 <1 ND

1.2.3-Trichloropropane µg/L 1 <1 <1 ND

Pentachloroethane µg/L 1 <1 <1 ND

1.2-Dibromo-3-chloropropane µg/L 1 <1 <1 ND

Hexachlorobutadiene µg/L 1 <1.0 <1.0 ND

Chloroform µg/L 1 <1 <1 ND

Bromodichloromethane µg/L 1 <1 <1 ND

Dibromochloromethane µg/L 1 <1 <1 ND

Bromoform µg/L 1 <1 <1 ND

Legend

ND = Not Detected (RPDs not calculated if both primary and duplicate results are below LOR)

- = Not analysed/calculated

Acceptable RPDs: RPD <= 30%

RPD > 30%, Analyis result < 10 times LOR

RPD <= 50%, Analysis result > 10 times LOR and < 20 times LOR

Project: Orica September 2014 Annual

Page 15: APPENDIX C - Orica

Duplicate Analysis RPDs Sample ID BP76_10.00_12/09/14 QC110_12/09/14 QC210_12/09/14

Project No. : 147623068 Sample Type Primary Field Duplicate Field Triplicate

Batch/es: ES1420737, 116361 Date Sampled 12/09/2014 12/09/2014 12/09/2014

Analyte Units LOR Primary vs Duplicate Primary vs Inter Duplicate

Carbon disulfide µg/L 1 26 26 - 0.00% -

1.2-Dibromoethane (EDB) µg/L 1 <1 <1 - ND -

Dichlorodifluoromethane µg/L 10 <10 <10 - ND -

Chloromethane µg/L 10 <10 <10 <10 ND ND

Vinyl chloride µg/L 10 679 663 560 2.38% 19.21%

Bromomethane µg/L 10 <10 <10 - ND -

Chloroethane µg/L 10 <10 <10 <10 ND ND

Trichlorofluoromethane µg/L 10 <10 <10 - ND -

1.1-Dichloroethene µg/L 1 65 76 - 15.60% -

Iodomethane µg/L 1 <1 <1 - ND -

Methylene chloride µg/L 5 <5 <5 <10 ND ND

trans-1.2-Dichloroethene µg/L 1 47 41 41 13.64% 13.64%

1.1-Dichloroethane µg/L 1 143 149 150 4.11% 4.78%

cis-1.2-Dichloroethene µg/L 1 402 416 410 3.42% 1.97%

1.1.1-Trichloroethane µg/L 1 <1 <1 <1 ND ND

1.1-Dichloropropylene µg/L 1 <1 <1 - ND -

Carbon Tetrachloride µg/L 1 <1 <1 <1 ND ND

1.2-Dichloroethane µg/L 1 30 28 30 6.90% 0.00%

Trichloroethene µg/L 1 3 3 3 0.00% 0.00%

Dibromomethane µg/L 1 <1 <1 - ND -

1.1.2-Trichloroethane µg/L 1 <1 <1 <1 ND ND

1.3-Dichloropropane µg/L 1 <1 <1 - ND -

Tetrachloroethene µg/L 1 <1 <1 <1 ND ND

1.1.1.2-Tetrachloroethane µg/L 1 <1 <1 <1 ND ND

trans-1.4-Dichloro-2-butene µg/L 1 <1 <1 - ND -

cis-1.4-Dichloro-2-butene µg/L 1 <1 <1 - ND -

1.1.2.2-Tetrachloroethane µg/L 1 <1 <1 <1 ND ND

1.2.3-Trichloropropane µg/L 1 1 <1 - ND -

Pentachloroethane µg/L 1 <1 <1 - ND -

1.2-Dibromo-3-chloropropane µg/L 1 <1 <1 - ND -

Hexachlorobutadiene µg/L 1 <1.0 <1.0 - ND -

Chloroform µg/L 1 5 5 6 0.00% 18.18%

Bromodichloromethane µg/L 1 <1 <1 - ND -

Dibromochloromethane µg/L 1 <1 <1 - ND -

Bromoform µg/L 1 <1 <1 - ND -

Legend

ND = Not Detected (RPDs not calculated if both primary and duplicate results are below LOR)

- = Not analysed/calculated

Acceptable RPDs: RPD <= 30%

RPD > 30%, Analyis result < 10 times LOR

RPD <= 50%, Analysis result > 10 times LOR and < 20 times LOR

Project: Orica September 2014 Annual

RPDs

Page 16: APPENDIX C - Orica

Duplicate Analysis RPDs Sample ID BP55_06.00_12/09/14 QC111_12/09/14

Project No. : 147623068 Sample Type Primary Field Duplicate

Batch/es: ES1420325 Date Sampled 12/09/2014 12/09/2014

RPDs

Analyte Units LOR Primary vs Duplicate

Carbon disulfide µg/L 1 <1 <1 ND

1.2-Dibromoethane (EDB) µg/L 1 <1 <1 ND

Dichlorodifluoromethane µg/L 10 <10 <10 ND

Chloromethane µg/L 10 <10 <10 ND

Vinyl chloride µg/L 10 <10.0 <10.0 ND

Bromomethane µg/L 10 <10 <10 ND

Chloroethane µg/L 10 <10 <10 ND

Trichlorofluoromethane µg/L 10 <10 <10 ND

1.1-Dichloroethene µg/L 1 <1 <1 ND

Iodomethane µg/L 1 <1 <1 ND

Methylene chloride µg/L 5 <5 <5 ND

trans-1.2-Dichloroethene µg/L 1 <1 <1 ND

1.1-Dichloroethane µg/L 1 <1 <1 ND

cis-1.2-Dichloroethene µg/L 1 <1 <1 ND

1.1.1-Trichloroethane µg/L 1 <1 <1 ND

1.1-Dichloropropylene µg/L 1 <1 <1 ND

Carbon Tetrachloride µg/L 1 <1 <1 ND

1.2-Dichloroethane µg/L 1 3 <1 ND

Trichloroethene µg/L 1 <1 <1 ND

Dibromomethane µg/L 1 <1 <1 ND

1.1.2-Trichloroethane µg/L 1 <1 <1 ND

1.3-Dichloropropane µg/L 1 <1 <1 ND

Tetrachloroethene µg/L 1 <1 <1 ND

1.1.1.2-Tetrachloroethane µg/L 1 <1 <1 ND

trans-1.4-Dichloro-2-butene µg/L 1 <1 <1 ND

cis-1.4-Dichloro-2-butene µg/L 1 <1 <1 ND

1.1.2.2-Tetrachloroethane µg/L 1 <1 <1 ND

1.2.3-Trichloropropane µg/L 1 <1 <1 ND

Pentachloroethane µg/L 1 <1 <1 ND

1.2-Dibromo-3-chloropropane µg/L 1 <1 <1 ND

Hexachlorobutadiene µg/L 1 <1.0 <1.0 ND

Vinyl chloride µg/L 1 <1

Chloroform µg/L 1 <1 <1 ND

Bromodichloromethane µg/L 1 <1 <1 ND

Dibromochloromethane µg/L 1 <1 <1 ND

Bromoform µg/L 1 <1 <1 ND

Legend

ND = Not Detected (RPDs not calculated if both primary and duplicate results are below LOR)

- = Not analysed/calculated

Acceptable RPDs: RPD <= 30%

RPD > 30%, Analyis result < 10 times LOR

RPD <= 50%, Analysis result > 10 times LOR and < 20 times LOR

Project: Orica September 2014 Annual

Page 17: APPENDIX C - Orica

Duplicate Analysis RPDs Sample ID BP60_04.00_12/09/14 QC112_12/09/14 QC212_12/09/14

Project No. : 147623068 Sample Type Primary Field Duplicate Field Triplicate

Batch/es: ES1420737, 116361 Date Sampled 12/09/2014 12/09/2014 12/09/2014

Analyte Units LOR Primary vs Duplicate Primary vs Inter Duplicate

Carbon disulfide µg/L 1 <1 <1 - ND -

1.2-Dibromoethane (EDB) µg/L 1 <1 <1 - ND -

Dichlorodifluoromethane µg/L 10 <10 <10 - ND -

Chloromethane µg/L 10 <10 <10 <10 ND ND

Vinyl chloride µg/L 10 <10.0 <10.0 <10 ND ND

Bromomethane µg/L 10 <10 <10 - ND -

Chloroethane µg/L 10 <10 <10 <10 ND ND

Trichlorofluoromethane µg/L 10 <10 <10 - ND -

1.1-Dichloroethene µg/L 1 <1 <1 - ND -

Iodomethane µg/L 1 <1 <1 - ND -

Methylene chloride µg/L 5 <5 <5 <10 ND ND

trans-1.2-Dichloroethene µg/L 1 <1 <1 <1 ND ND

1.1-Dichloroethane µg/L 1 <1 <1 <1 ND ND

cis-1.2-Dichloroethene µg/L 1 1 2 <1 66.67% ND

1.1.1-Trichloroethane µg/L 1 <1 <1 <1 ND ND

1.1-Dichloropropylene µg/L 1 <1 <1 - ND -

Carbon Tetrachloride µg/L 1 <1 <1 <1 ND ND

1.2-Dichloroethane µg/L 1 162 191 4 16.43% 190.36%

Trichloroethene µg/L 1 <1 <1 <1 ND ND

Dibromomethane µg/L 1 <1 <1 - ND -

1.1.2-Trichloroethane µg/L 1 <1 <1 <1 ND ND

1.3-Dichloropropane µg/L 1 <1 <1 - ND -

Tetrachloroethene µg/L 1 <1 <1 <1 ND ND

1.1.1.2-Tetrachloroethane µg/L 1 <1 <1 <1 ND ND

trans-1.4-Dichloro-2-butene µg/L 1 <1 <1 - ND -

cis-1.4-Dichloro-2-butene µg/L 1 <1 <1 - ND -

1.1.2.2-Tetrachloroethane µg/L 1 1 2 <1 66.67% ND

1.2.3-Trichloropropane µg/L 1 <1 <1 - ND -

Pentachloroethane µg/L 1 <1 <1 - ND -

1.2-Dibromo-3-chloropropane µg/L 1 <1 <1 - ND -

Hexachlorobutadiene µg/L 1 <1.0 <1.0 - ND -

Vinyl chloride µg/L 1 1 - - ND -

Chloroform µg/L 1 <1 <1 <1 ND ND

Bromodichloromethane µg/L 1 <1 <1 - ND -

Dibromochloromethane µg/L 1 <1 <1 - ND -

Bromoform µg/L 1 <1 <1 - ND -

Legend

ND = Not Detected (RPDs not calculated if both primary and duplicate results are below LOR)

- = Not analysed/calculated

RPD outside of quality objectives.

Acceptable RPDs: RPD <= 30%

RPD > 30%, Analyis result < 10 times LOR

RPD <= 50%, Analysis result > 10 times LOR and < 20 times LOR

Project: Orica September 2014 Annual

RPDs

Page 18: APPENDIX C - Orica

Duplicate Analysis RPDs Sample ID BP60_28.00_12/09/14 QC113_12/09/14

Project No. : 147623068 Sample Type Primary Field Duplicate

Batch/es: ES1420737 Date Sampled 12/09/2014 12/09/2014

RPDs

Analyte Units LOR Primary vs Duplicate

Carbon disulfide µg/L 1 11 <5 ND

1.2-Dibromoethane (EDB) µg/L 1 <5 <5 ND

Dichlorodifluoromethane µg/L 10 <50 <50 ND

Chloromethane µg/L 10 <50 <50 ND

Vinyl chloride µg/L 10 442 352 22.67%

Bromomethane µg/L 10 <50 <50 ND

Chloroethane µg/L 10 <50 <50 ND

Trichlorofluoromethane µg/L 10 <50 <50 ND

1.1-Dichloroethene µg/L 1 <5 <5 ND

Iodomethane µg/L 1 <5 <5 ND

Methylene chloride µg/L 5 <5 <5 ND

trans-1.2-Dichloroethene µg/L 1 6 <5 ND

1.1-Dichloroethane µg/L 1 128 103 21.65%

cis-1.2-Dichloroethene µg/L 1 21 12 54.55%

1.1.1-Trichloroethane µg/L 1 <5 <5 ND

1.1-Dichloropropylene µg/L 1 <5 <5 ND

Carbon Tetrachloride µg/L 1 <5 <5 ND

1.2-Dichloroethane µg/L 1 2240 1780 22.89%

Trichloroethene µg/L 1 11 8 31.58%

Dibromomethane µg/L 1 <5 <5 ND

1.1.2-Trichloroethane µg/L 1 <5 <5 ND

1.3-Dichloropropane µg/L 1 <5 <5 ND

Tetrachloroethene µg/L 1 <5 <5 ND

1.1.1.2-Tetrachloroethane µg/L 1 <5 <5 ND

trans-1.4-Dichloro-2-butene µg/L 1 <5 <5 ND

cis-1.4-Dichloro-2-butene µg/L 1 <5 <5 ND

1.1.2.2-Tetrachloroethane µg/L 1 <5 <5 ND

1.2.3-Trichloropropane µg/L 1 <5 <5 ND

Pentachloroethane µg/L 1 <5 <5 ND

1.2-Dibromo-3-chloropropane µg/L 1 <5 <5 ND

Hexachlorobutadiene µg/L 1 <5.0 <5.0 ND

Vinyl chloride µg/L 1 - - ND

Chloroform µg/L 1 40 28 35.29%

Bromodichloromethane µg/L 1 <5 <5 ND

Dibromochloromethane µg/L 1 <5 <5 ND

Bromoform µg/L 1 <5 <5 ND

Legend

ND = Not Detected (RPDs not calculated if both primary and duplicate results are below LOR)

- = Not analysed/calculated

RPD exceedence

Acceptable RPDs: RPD <= 30%

RPD > 30%, Analyis result < 10 times LOR

RPD <= 50%, Analysis result > 10 times LOR and < 20 times LOR

Project: Orica September 2014 Annual

Page 19: APPENDIX C - Orica

Duplicate Analysis RPDs Sample ID WG154S_12/09/14 QC114_12/09/14 QC214_12/09/14

Project No. : 147623068 Sample Type Primary Field Duplicate Field Triplicate

Batch/es: ES1420737 Date Sampled 12/09/2014 12/09/2014 12/09/2014

Analyte Units LOR Primary vs Duplicate Primary vs Inter Duplicate

Carbon disulfide µg/L 1 1 1 - 0.00% -

1.2-Dibromoethane (EDB) µg/L 1 <1 <1 - ND -

Dichlorodifluoromethane µg/L 10 <10 <10 - ND -

Chloromethane µg/L 10 <10 <10 <10 ND ND

Vinyl chloride µg/L 10 <10.0 <10.0 <10 ND ND

Bromomethane µg/L 10 <10 <10 - ND -

Chloroethane µg/L 10 <10 <10 <10 ND ND

Trichlorofluoromethane µg/L 10 <10 <10 - ND -

1.1-Dichloroethene µg/L 1 <1 <1 - ND -

Iodomethane µg/L 1 <1 <1 - ND -

Methylene chloride µg/L 5 <5 <5 <10 ND ND

trans-1.2-Dichloroethene µg/L 1 <1 <1 <1 ND ND

1.1-Dichloroethane µg/L 1 51 41 46 21.74% 10.31%

cis-1.2-Dichloroethene µg/L 1 1 2 1 66.67% 0.00%

1.1.1-Trichloroethane µg/L 1 <1 <1 <1 ND ND

1.1-Dichloropropylene µg/L 1 <1 <1 - ND -

Carbon Tetrachloride µg/L 1 <1 <1 <1 ND ND

1.2-Dichloroethane µg/L 1 13 11 15 16.67% 14.29%

Trichloroethene µg/L 1 2 2 2 0.00% 0.00%

Dibromomethane µg/L 1 <1 <1 - ND -

1.1.2-Trichloroethane µg/L 1 <1 <1 <1 ND ND

1.3-Dichloropropane µg/L 1 <1 <1 - ND -

Tetrachloroethene µg/L 1 1 2 2 66.67% 66.67%

1.1.1.2-Tetrachloroethane µg/L 1 <1 <1 <1 ND ND

trans-1.4-Dichloro-2-butene µg/L 1 <1 <1 - ND -

cis-1.4-Dichloro-2-butene µg/L 1 <1 <1 - ND -

1.1.2.2-Tetrachloroethane µg/L 1 <1 <1 <1 ND ND

1.2.3-Trichloropropane µg/L 1 <1 <1 - ND -

Pentachloroethane µg/L 1 <1 <1 - ND -

1.2-Dibromo-3-chloropropane µg/L 1 <1 <1 - ND -

Hexachlorobutadiene µg/L 1 <1.0 <1.0 - ND -

Chloroform µg/L 1 2 3 3 40.00% 40.00%

Bromodichloromethane µg/L 1 <1 <1 - ND -

Dibromochloromethane µg/L 1 <1 <1 - ND -

Bromoform µg/L 1 <1 <1 - ND -

Legend

ND = Not Detected (RPDs not calculated if both primary and duplicate results are below LOR)

- = Not analysed/calculated

Acceptable RPDs: RPD <= 30%

RPD > 30%, Analyis result < 10 times LOR

RPD <= 50%, Analysis result > 10 times LOR and < 20 times LOR

Project: Orica September 2014 Annual

RPDs

Page 20: APPENDIX C - Orica

Duplicate Analysis RPDs Sample ID WG231S_12/09/14 QC115_12/09/14

Project No. : 147623068 Sample Type Primary Field Duplicate

Batch/es: ES1420737 Date Sampled 12/09/2014 12/09/2014

RPDs

Analyte Units LOR Primary vs Duplicate

Carbon disulfide µg/L 1 <1 <1 ND

1.2-Dibromoethane (EDB) µg/L 1 <1 <1 ND

Dichlorodifluoromethane µg/L 10 <10 <10 ND

Chloromethane µg/L 10 <10 <10 ND

Vinyl chloride µg/L 10 <10.0 <10.0 ND

Bromomethane µg/L 10 <10 <10 ND

Chloroethane µg/L 10 <10 <10 ND

Trichlorofluoromethane µg/L 10 <10 <10 ND

1.1-Dichloroethene µg/L 1 <1 <1 ND

Iodomethane µg/L 1 <1 <1 ND

Methylene chloride µg/L 5 <5 <5 ND

trans-1.2-Dichloroethene µg/L 1 <1 <1 ND

1.1-Dichloroethane µg/L 1 <1 <1 ND

cis-1.2-Dichloroethene µg/L 1 1 1 0.00%

1.1.1-Trichloroethane µg/L 1 <1 <1 ND

1.1-Dichloropropylene µg/L 1 <1 <1 ND

Carbon Tetrachloride µg/L 1 <1 <1 ND

1.2-Dichloroethane µg/L 1 3 3 0.00%

Trichloroethene µg/L 1 <1 <1 ND

Dibromomethane µg/L 1 <1 <1 ND

1.1.2-Trichloroethane µg/L 1 <1 <1 ND

1.3-Dichloropropane µg/L 1 <1 <1 ND

Tetrachloroethene µg/L 1 <1 <1 ND

1.1.1.2-Tetrachloroethane µg/L 1 <1 <1 ND

trans-1.4-Dichloro-2-butene µg/L 1 <1 <1 ND

cis-1.4-Dichloro-2-butene µg/L 1 <1 <1 ND

1.1.2.2-Tetrachloroethane µg/L 1 <1 <1 ND

1.2.3-Trichloropropane µg/L 1 <1 <1 ND

Pentachloroethane µg/L 1 <1 <1 ND

1.2-Dibromo-3-chloropropane µg/L 1 <1 <1 ND

Hexachlorobutadiene µg/L 1 <1.0 <1.0 ND

Chloroform µg/L 1 <1 <1 ND

Bromodichloromethane µg/L 1 <1 <1 ND

Dibromochloromethane µg/L 1 <1 <1 ND

Bromoform µg/L 1 <1 <1 ND

Legend

ND = Not Detected (RPDs not calculated if both primary and duplicate results are below LOR)

- = Not analysed/calculated

Acceptable RPDs: RPD <= 30%

RPD > 30%, Analyis result < 10 times LOR

RPD <= 50%, Analysis result > 10 times LOR and < 20 times LOR

Project: Orica September 2014 Annual

Page 21: APPENDIX C - Orica

Number of Primary Samples: Number of Triplicate Samples:

Number of Duplicate Samples: Number of Other QAQC Samples:

Sample volumes sufficient for QC analysis?

Type

MB Method BlankTB Trip Blank

Analyte Group Analyte(s) Sample ID

Analyte Group Primary ID Duplicate ID

WG233S_15/09/14 QC116_15/09/14WG229S_15/09/14 QC117_15/09/14

Halogenated aliphatic

compoundsBP59_08.00_15/09/14/ QC118_15/09/14

Analyte Group Primary ID Triplicate ID

WG233S_15/09/14 QC216_15/09/14

Halogenated aliphatic

compoundsBP59_08.00_15/09/14/ QC218_15/09/14

Analyte Group Analyte(s)

Note: Data validation assesses each analyte in terms of all the data validation variables and only the exceedances and outliers are reported in this form.

*When concentrations are less than the LOR for both primary and duplicate/triplicate results, no RPDs are calculated

Performed By: Philippe Koenig Checked By Fabiana Quinton

Date: 28/10/2014 Date: 3/11/2014

This batch has been validated and is considered suitable for environmental interpretive use.

Overall Comments

As stated by ALS: 'EP074WF: Positive results of QC118_15/09/14 have been confirmed by re-analysis. EP074WF:Particular samples required dilution due to the presence of high level contaminants. LOR values

have been adjusted accordingly.'

LCS recovery of 1.1.1.2-tetrachloroethane (81.2%) and dibromochloromethane (79.2%) lower than lower quality objective (82.6% & 80.4% respectively) in sample WG233I_15/09/14. This is not expected to affect the

validity of these results, as exceedence from acceptable criteria was marginal (>1.5% for both analytes). Furthermore, MS & Surrogate recoveries of these analytes and other halogenated aliphatic compounds and

tirhalomethanes were within laboratory based quality objectives.

FD RPDs of 1.1-Dichloroethene & 1.1-Dichloroethane (39.1% & 38.8%) exceed the quality objective (30%) for primary sample BP59_08.00_15/09/14. This is not expected to affect the validity of this batch as

exceedence was marginal (9%). Furthermore, MS, LCS and surrogate recovery of these analytes are within laboratory quality objectives. As a conservative measure, the highest value will be used for interperative

purposes.

FT RPDs of Vinyl chloride (48%) & 1.1-dichloroethane (62%) exceed the quality objective (30%) for primary sample BP59_08.00_15/09/14.This may be due to different techniques used by the two laboratories and is

not exected to affect the validity of this batch. As a conservative measure, the highest value will be used for interperative purposes.

Surrogate Compound Monitoring Analyses

CommentsAll surrogate recoveries are within the laboratory based quality objectives. (ALS & ELS).

FD RPDs of 1.1-Dichloroethene (39.1%) & 1.1-Dichloroethane (38.8%) exceed the quality objective. See

comments. All other RPDs are within quality objectives.

Field Triplicates (FT) Analyses

CommentsAll FT RPDs are within quality objectives.

FT RPDs of Vinyl chloride (48%) and 1.1-Dichloroethane (62%) exceed the quality objective. See

comments. All other RPDs are within quality objectives.

All LD RPDs are within the laboratory based quality objectives. All LDs conducted on Orica samples (ALS

& ELS).

Field Duplicates (FD) Analyses

CommentsAll FD RPDs are within quality objectives.All FD RPDs are within quality objectives.

Laboratory Duplicates (LD) Analyses

Comments

All MS recoveries are within the laboratory based quality objectives. MS was conducted on Orica samples (ALS). ELS did not perform a

MS for this batch.

Laboratory Control Spike (LCS) Analyses

Analyte Group Comments

Halogenated Aliphatic Compounds & TrihalomethanesLCS recovery of 1.1.1.2-tetrachloroethane (81.2%) and dibromochloromethane (79.2%) less than lower quality objective (82.6% & 80.4%

respectively). See comments.All other LCS recoveries are within the laboratory based quality objectives. (ALS & ELS).

No TS was prepared in this batch.

Matrix Spike (MS) Analyses

Analyte Group Comments

All results below the LOR. (ALS & ELS).All results below the LOR. (ALS).

Trip Spike Information

Analyte Spike Concentrations Recovery Concentration %

RecoveryComments

Laboratory reports signed by authorised personnel? Y Yes. All.

QAQC Sample Information (Method Blank - MB, Rinsate Blank - RB, Field Blank - FB, Trip Blank - TB)

Sample ID Comments

Y Yes.Are there non-NATA accredited methods used? N No.

DATA VALIDATION SUMMARY SHEET (Sydney)

Project Name: Orica September Quarterly 2014 Project Number: 147623068

3 1

Documentation and Sample Handling Information

Date Sampled: 15 September 2014 Sample Medium: Water

Sample Information

23 2

Primary Laboratory: ALS Workorder Number: ES1420811

Secondary Laboratory: ELS Workorder Number: 116286

Y/N Comments

Samples received intact and chilled? YALS: '4.0'C - Ice present. Client dropoff.' ELS: 'temperature 14.8'C, ice, security -

intact.'

Samples analysed within appropriate holding times? Y Yes. All.

COC completed properly? Y Yes. Signed by both field and laboratory personnel.All requested analysis completed? Y Yes. All.

Page 22: APPENDIX C - Orica

Duplicate Analysis RPDs Sample ID WG233S_15/09/14 QC116_15/09/14 QC216_15/09/14

Project No. : 147623068 Sample Type Primary Field Duplicate Field Triplicate

Batch/es: ES1420811, 116286 Date Sampled 15/09/2014 15/09/2014 15/09/2014

Analyte Units LOR Primary vs Duplicate Primary vs Inter Duplicate

Carbon disulfide µg/L 1 <1 <1 - ND -

1.2-Dibromoethane (EDB) µg/L 1 <1 <1 - ND -

Dichlorodifluoromethane µg/L 10 <10 <10 - ND -

Chloromethane µg/L 10 <10 <10 <10 ND ND

Vinyl chloride µg/L 10 <10.0 <10.0 <10 ND ND

Bromomethane µg/L 10 <10 <10 - ND -

Chloroethane µg/L 10 <10 <10 <10 ND ND

Trichlorofluoromethane µg/L 10 <10 <10 - ND -

1.1-Dichloroethene µg/L 1 <1 <1 - ND -

Iodomethane µg/L 1 <1 <1 - ND -

Methylene chloride µg/L 5 <5 <5 <10 ND ND

trans-1.2-Dichloroethene µg/L 1 <1 <1 <1 ND ND

1.1-Dichloroethane µg/L 1 <1 <1 <1 ND ND

cis-1.2-Dichloroethene µg/L 1 <1 <1 <1 ND ND

1.1.1-Trichloroethane µg/L 1 <1 <1 <1 ND ND

1.1-Dichloropropylene µg/L 1 <1 <1 - ND -

Carbon Tetrachloride µg/L 1 <1 <1 <1 ND ND

1.2-Dichloroethane µg/L 1 <1 <1 <1 ND ND

Trichloroethene µg/L 1 <1 <1 <1 ND ND

Dibromomethane µg/L 1 <1 <1 - ND -

1.1.2-Trichloroethane µg/L 1 <1 <1 <1 ND ND

1.3-Dichloropropane µg/L 1 <1 <1 - ND -

Tetrachloroethene µg/L 1 <1 <1 <1 ND ND

1.1.1.2-Tetrachloroethane µg/L 1 <1 <1 <1 ND ND

trans-1.4-Dichloro-2-butene µg/L 1 <1 <1 - ND -

cis-1.4-Dichloro-2-butene µg/L 1 <1 <1 - ND -

1.1.2.2-Tetrachloroethane µg/L 1 <1 <1 <1 ND ND

1.2.3-Trichloropropane µg/L 1 <1 <1 - ND -

Pentachloroethane µg/L 1 <1 <1 - ND -

1.2-Dibromo-3-chloropropane µg/L 1 <1 <1 - ND -

Hexachlorobutadiene µg/L 1 <1.0 <1.0 - ND -

Vinyl chloride µg/L 1 <1 - - ND -

Chloroform µg/L 1 <1 <1 <1 ND ND

Bromodichloromethane µg/L 1 <1 <1 - ND -

Dibromochloromethane µg/L 1 <1 <1 - ND -

Bromoform µg/L 1 <1 <1 - ND -

Legend

ND = Not Detected (RPDs not calculated if both primary and duplicate results are below LOR)

- = Not analysed/calculated

Acceptable RPDs: RPD <= 30%

RPD > 30%, Analyis result < 10 times LOR

RPD <= 50%, Analysis result > 10 times LOR and < 20 times LOR

Project: Orica September 2014 Annual

RPDs

Page 23: APPENDIX C - Orica

Duplicate Analysis RPDs Sample ID WG229S_15/09/14 QC117_15/09/14

Project No. : 147623068 Sample Type Primary Field Duplicate

Batch/es: ES1420811 Date Sampled 15/09/2014 15/09/2014

RPDs

Analyte Units LOR Primary vs Duplicate

Carbon disulfide µg/L 1 <1 <1 ND

1.2-Dibromoethane (EDB) µg/L 1 <1 <1 ND

Dichlorodifluoromethane µg/L 10 <10 <10 ND

Chloromethane µg/L 10 <10 <10 ND

Vinyl chloride µg/L 10 <10.0 <10.0 ND

Bromomethane µg/L 10 <10 <10 ND

Chloroethane µg/L 10 <10 <10 ND

Trichlorofluoromethane µg/L 10 <10 <10 ND

1.1-Dichloroethene µg/L 1 <1 <1 ND

Iodomethane µg/L 1 <1 <1 ND

Methylene chloride µg/L 5 <5 <5 ND

trans-1.2-Dichloroethene µg/L 1 <1 <1 ND

1.1-Dichloroethane µg/L 1 <1 <1 ND

cis-1.2-Dichloroethene µg/L 1 <1 <1 ND

1.1.1-Trichloroethane µg/L 1 <1 <1 ND

1.1-Dichloropropylene µg/L 1 <1 <1 ND

Carbon Tetrachloride µg/L 1 <1 <1 ND

1.2-Dichloroethane µg/L 1 10 10 0.00%

Trichloroethene µg/L 1 <1 <1 ND

Dibromomethane µg/L 1 <1 <1 ND

1.1.2-Trichloroethane µg/L 1 <1 <1 ND

1.3-Dichloropropane µg/L 1 <1 <1 ND

Tetrachloroethene µg/L 1 <1 <1 ND

1.1.1.2-Tetrachloroethane µg/L 1 <1 <1 ND

trans-1.4-Dichloro-2-butene µg/L 1 <1 <1 ND

cis-1.4-Dichloro-2-butene µg/L 1 <1 <1 ND

1.1.2.2-Tetrachloroethane µg/L 1 <1 <1 ND

1.2.3-Trichloropropane µg/L 1 <1 <1 ND

Pentachloroethane µg/L 1 <1 <1 ND

1.2-Dibromo-3-chloropropane µg/L 1 <1 <1 ND

Hexachlorobutadiene µg/L 1 <1.0 <1.0 ND

Vinyl chloride µg/L 1 <1 - ND

Chloroform µg/L 1 <1 <1 ND

Bromodichloromethane µg/L 1 <1 <1 ND

Dibromochloromethane µg/L 1 <1 <1 ND

Bromoform µg/L 1 <1 <1 ND

Legend

ND = Not Detected (RPDs not calculated if both primary and duplicate results are below LOR)

- = Not analysed/calculated

Acceptable RPDs: RPD <= 30%

RPD > 30%, Analyis result < 10 times LOR

RPD <= 50%, Analysis result > 10 times LOR and < 20 times LOR

Project: Orica September 2014 Annual

Page 24: APPENDIX C - Orica

Duplicate Analysis RPDs Sample ID BP59_08.00_15/09/14 QC118_15/09/14 QC218_15/09/14

Project No. : 147623068 Sample Type Primary Field Duplicate Field Triplicate

Batch/es: ES1420811, 116286 Date Sampled 15/09/2014 15/09/2014 15/09/2014

Analyte Units LOR Primary vs Duplicate Primary vs Inter Duplicate

Carbon disulfide µg/L 1 11 7 - 44.44% -

1.2-Dibromoethane (EDB) µg/L 1 <5 <5 - ND -

Dichlorodifluoromethane µg/L 10 <50 <50 - ND -

Chloromethane µg/L 10 <50 <50 <10 ND ND

Vinyl chloride µg/L 10 3980 4360 6500 9.11% 48.09%

Bromomethane µg/L 10 <50 <50 - ND -

Chloroethane µg/L 10 <50 <50 <10 ND ND

Trichlorofluoromethane µg/L 10 <50 <50 - ND -

1.1-Dichloroethene µg/L 1 72 107 - 39.11% -

Iodomethane µg/L 1 <5 <5 - ND -

Methylene chloride µg/L 5 129 159 <10 20.83% ND

trans-1.2-Dichloroethene µg/L 1 961 1080 1200 11.66% 22.12%

1.1-Dichloroethane µg/L 1 27 40 51 38.81% 61.54%

cis-1.2-Dichloroethene µg/L 1 6640 7040 6800 5.85% 2.38%

1.1.1-Trichloroethane µg/L 1 <5 <5 <1 ND ND

1.1-Dichloropropylene µg/L 1 <5 <5 - ND -

Carbon Tetrachloride µg/L 1 <5 <5 <1 ND ND

1.2-Dichloroethane µg/L 1 7070 7130 6400 0.85% 9.95%

Trichloroethene µg/L 1 419 468 450 11.05% 7.13%

Dibromomethane µg/L 1 <5 <5 - ND -

1.1.2-Trichloroethane µg/L 1 11 8 9 31.58% 20.00%

1.3-Dichloropropane µg/L 1 <5 <5 - ND -

Tetrachloroethene µg/L 1 1880 1720 1700 8.89% 10.06%

1.1.1.2-Tetrachloroethane µg/L 1 <5 <5 <1 ND ND

trans-1.4-Dichloro-2-butene µg/L 1 <5 <5 - ND -

cis-1.4-Dichloro-2-butene µg/L 1 <5 <5 - ND -

1.1.2.2-Tetrachloroethane µg/L 1 12 11 16 8.70% 28.57%

1.2.3-Trichloropropane µg/L 1 <5 <5 - ND -

Pentachloroethane µg/L 1 <5 <5 - ND -

1.2-Dibromo-3-chloropropane µg/L 1 <5 <5 - ND -

Hexachlorobutadiene µg/L 1 <5.0 <5.0 - ND -

Vinyl chloride µg/L 1 - - ND -

Chloroform µg/L 1 1150 1210 1300 5.08% 12.24%

Bromodichloromethane µg/L 1 <5 <5 - ND -

Dibromochloromethane µg/L 1 <5 <5 - ND -

Bromoform µg/L 1 <5 <5 - ND -

Legend

ND = Not Detected (RPDs not calculated if both primary and duplicate results are below LOR)

- = Not analysed/calculated

Acceptable RPDs: RPD <= 30%

RPD > 30%, Analyis result < 10 times LOR

RPD <= 50%, Analysis result > 10 times LOR and < 20 times LOR

Project: Orica September 2014 Annual

RPDs