311
Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General Services Administration Public Buildings Service Southeast Sunbelt Region Real Estate Design and Construction UNCLASSIFIED APPENDIX A – ROOM DATA SHEETS

APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007

General Services Administration Public Buildings Service Southeast Sunbelt Region Real Estate Design and Construction

UNCLASSIFIED

APPENDIX A – ROOM DATA SHEETS

Page 2: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007

General Services Administration Public Buildings Service Southeast Sunbelt Region Real Estate Design and Construction

UNCLASSIFIED

BASE CONTRACT

Page 3: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 101

Room Name Entry

Net Area 100

Quantity 1

Adjacency Locate along public corridor.Adjacent to Secretary.Shared with Business Office.

Floor Finish Carpet 36 oz

Wall Finish Paint & FWC

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL w/Side Lite

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Includes Seating Area for 4.

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( x )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc): 10

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 4: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 102

Room Name Secretary

Net Area 100

Quantity 1

Adjacency Entry, Director's Office, Marketing Public Affairs Office, Director's Meeting Room, and Work/Copy Room.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Secretarial workstation with 2 visitor chairs.Provide observation window.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control NoneCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Emergency phone.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 5: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 103

Room Name Director's Office

Net Area 224

Quantity 1

Adjacency Secretary, Director's Meeting Room

Floor Finish Carpet 36 oz

Wall Finish Paint & FWC

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Executive desk and credenza with 2 visitor chairs.Conference table for 4 with storage unit.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( x )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 6: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 104

Room Name Deputy Director's Office

Net Area 168

Quantity 1

Adjacency Director's Office, Director's Meeting Room.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.Conference table for 2 and storage unit.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 7: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 105

Room Name Director's Meeting Room / EOC

Net Area 600

Quantity 1

Adjacency Director's Office, Secretary, Entry,Work / Copy Room

Floor Finish Carpet 36 oz

Wall Finish Paint & FWC

Base Wood

Ceiling Finish ACT w/GWB Accents

Door Type Wood DBL

Wall Construction Metal Stud w/GWB

Casework Wood Base & SOlid Surface Top

Equipment AV System.Include ceiling-mounted projector, motorized projection screen, and wall-mounted whiteboard.

Arch Notes Conference room also serves as Emergency Operations Center (EOC).Include board table and seating for 12.Room shall have direct access from corridor and Director's office.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( x ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( x )

Tele Data Special Requirements

Include teleconferencing capacity.Provide multiple telephone and data outlets for use as EOC, including CCTV monitoring station.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Provide standby power to allow space to be used as Emergency Operations Center.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Dimming

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 8: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 106

Room Name Marketing Public Affairs Off.

Net Area 200

Quantity 1

Adjacency Secretary, Director's Office.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs, andconference table.Room for "fireside chats."

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( x )

Tele Data Special Requirements

Include channel 99 equipment (approximately 3' square - flat screen TV)

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 9: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 107

Room Name Agency / Multi-Use Office

Net Area 120

Quantity 1

Adjacency Secretary, Entry.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 10: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 108

Room Name Staff Break Area / Work / Copy Room

Net Area 225

Quantity 1

Adjacency Locate on Internal corridor adjacent to Director's Meeting Room, Secretary.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework Plam Wall Base & Top

Equipment Copiers, fax machines, and printers.Full-size refrigerator.

Arch Notes Storage cabinets and work counters.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Provide additional voice / data lines (copiers, fax machines).

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 11: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 109

Room Name Safety Officer

Net Area 120

Quantity 1

Adjacency Administrative Officer and Deputy Director's Office.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Executive Desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

May 21, 2007AFRH Gulport RFP Base Bid

Page 12: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 110

Room Name Administrative Officer

Net Area 120

Quantity 1

Adjacency Safety Officer and Deputy Director's Office.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

May 21, 2007AFRH Gulport RFP Base Bid

Page 13: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 111

Room Name Master Chief / Ombudsman

Net Area 120

Quantity 1

Adjacency Director's Office, Secretary

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 14: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 112

Room Name Staff Men's Toilet

Net Area 70

Quantity 1

Adjacency Entry and Secretary.

Floor Finish Ceramic Tile

Wall Finish Ceramic Tile 1/2 Ht.

Base Ceramic

Ceiling Finish Painted GWB

Door Type Wood SGL

Wall Construction CMU w/GWB

Casework Plam Base & Top

Equipment Provide complete stainless steel toilet accessories.

Arch Notes Provide one ADA accessible sink and toilet in each Toilet Room.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( x ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Privacy SetCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

May 21, 2007AFRH Gulport RFP Base Bid

Page 15: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 113

Room Name Staff Women's Toilet

Net Area 70

Quantity 1

Adjacency Entry and Secretary.

Floor Finish Ceramic Tile

Wall Finish Ceramic Tile 1/2 Ht.

Base Ceramic

Ceiling Finish Painted GWB

Door Type Wood SGL

Wall Construction CMU w/GWB

Casework Plam Base & Top

Equipment Provide complete stainless steel toilet accessories.

Arch Notes Provide one ADA accessible sink and toilet in each Toilet Room.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( x ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Privacy SetCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

May 21, 2007AFRH Gulport RFP Base Bid

Page 16: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 114

Room Name IT Employee / Contractor Office

Net Area 240

Quantity 1

Adjacency Locate on public corridor.Adjacent to IT Training Room and IT Server Room.Locate near Business Office.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL w/Side Lite

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes 2 workstation cubicles and 1 workbench.Contain one employee, one contractor, and one open workstation.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 17: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 115

Room Name IT Training Room

Net Area 400

Quantity 1

Adjacency Locate along public corridor.Adjacent to IT Office, IT Secure Storage, and IT Server Room.

Floor Finish Carpet 36 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood DBL

Wall Construction Metal Stud w/GWB

Casework

Equipment AV System.Include ceiling-mounted projector, motorized projection screen, and wall-mounted whiteboard.

Arch Notes Tables and seating for 12 students and 1 instructor with storage unit.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( x ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( x )

Tele Data Special Requirements

Provide additional voice and data capacity.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 18: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 116

Room Name IT Secure Storage

Net Area 100

Quantity 1

Adjacency IT Training Room

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 19: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 117

Room Name IT Server Room

Net Area 300

Quantity 1

Adjacency IT Employee / Contractor Office and IT Training Room.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment Computer Servers and related equipment.PBX and main telephone switch.

Arch Notes Raised flooring throughout.Dedicated HVAC service.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 72 Deg (F)

% R Humidity (Winter) 45%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

LAN Fiber / CAT MDF.Provide additional voice and data capacity.

Sprinkler FM 200

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Provide UPS System with 4-hour battery backup to support IT equipment.Provide standby power for 4-hour IT equipment.Provide standby power for HVAC service.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 20: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 118

Room Name IT Distribution Closets

Net Area 25

Quantity 19

Adjacency

Floor Finish Sealed Concrete

Wall Finish Paint

Base None

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment Protect in cabinet Data Switch.

Arch Notes Lockable cabinets for telephone, data, and cable TV.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Key OnlyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

May 21, 2007AFRH Gulport RFP Base Bid

Page 21: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 119

Room Name Business Office Chief

Net Area 120

Quantity 1

Adjacency Director Gulfport Entry

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 22: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 120

Room Name Business Offices

Net Area 100

Quantity 3

Adjacency Business Office Chief

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 23: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 201

Room Name Chief of Campus Operations

Net Area 200

Quantity 1

Adjacency Campus Operations Office Assistant.Contract Surv. Specialists.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.Conference table for 4 with storage unit.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 24: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 202

Room Name Campus Operations Office Assistant

Net Area 80

Quantity 1

Adjacency Locate along public corridor.Adjacent to Chief of Campus Operations.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL w/Side Lite

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Secretarial workstation.Functions as Chief of Campus Operations' Reception

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 25: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 203

Room Name Facilities Maintenance Supervisor

Net Area 120

Quantity 1

Adjacency FM Contractor Shop and Chief of Campus Operations

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 26: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 204

Room Name Engineering Technician

Net Area 100

Quantity 1

Adjacency Chief of Campus Ops.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard Desk.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 27: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 205

Room Name Contract Surv. Specialists

Net Area 80

Quantity 3

Adjacency FM Supervisor.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Secretarial workstations.Locate in same room.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 28: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 206

Room Name Contractor Supervisor

Net Area 120

Quantity 1

Adjacency FM Contractor Shop

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 29: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 207

Room Name Service Desk

Net Area 80

Quantity 1

Adjacency Locate along public corridor.Adjacent to Contractor Supervisor and FM Contractor Shop.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL w/Side Lite

Wall Construction Metal Stud w/GWB

Casework Reception Desk

Equipment

Arch Notes Secretarial workstation with 2 visitor chairs.Function as reception for FM Contractor Shop.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 30: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 208

Room Name FM Contractor Shop

Net Area 4000

Quantity 1

Adjacency Locate along public corridor.Adjacent to Service Desk.Easy access to Loading Dock & Service Elevators.

Floor Finish Sealed Concrete

Wall Finish Paint

Base Vinyl

Ceiling Finish No Ceiling

Door Type Metal DBL

Wall Construction CMU

Casework

Equipment Equipment and casework provided by contractor.

Arch Notes Includes room for 8 workstations, and a separate shop area with "attic stock" storage.Similar to NAVFAC P-80 Standard.

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) -

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Utility sink (wall-mounted).

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Provide additional voice and data capacity.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 31: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 209

Room Name Maintenance Work Area

Net Area 2000

Quantity 1

Adjacency FM Contractor Shop

Floor Finish Sealed Concrete

Wall Finish Paint

Base Vinyl

Ceiling Finish No Ceiling

Door Type Metal DBL

Wall Construction CMU

Casework

Equipment

Arch Notes Maintenance area for long-term projects.

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) -

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 32: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 210

Room Name Building Supply

Net Area 400

Quantity 1

Adjacency Maintenance Work Area

Floor Finish Sealed Concrete

Wall Finish Paint

Base Vinyl

Ceiling Finish No Ceiling

Door Type Metal DBL

Wall Construction CMU

Casework

Equipment

Arch Notes Includes space for storage of building materials.

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) -

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 33: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 211

Room Name Active Repair

Net Area 500

Quantity 1

Adjacency Maintenance Work Area

Floor Finish Sealed Concrete

Wall Finish Paint

Base Vinyl

Ceiling Finish No Ceiling

Door Type Metal DBL

Wall Construction CMU

Casework

Equipment Equipment and casework provided by contractor.

Arch Notes Repair equipment.

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) -

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 34: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 212

Room Name HVAC Crew

Net Area 500

Quantity 1

Adjacency Maintenance Work Station

Floor Finish Sealed Concrete

Wall Finish Paint

Base Vinyl

Ceiling Finish No Ceiling

Door Type Metal DBL

Wall Construction CMU

Casework

Equipment Equipment and casework provided by contractor.

Arch Notes Fume hood for welding / soldering.

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) -

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 35: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 213

Room Name Logistics Supervisor

Net Area 120

Quantity 1

Adjacency Near Chief of Campus Operations.Easy access to Loading Dock.Adjacent to Transportation Specialist and close to Supply Area.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 36: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 214

Room Name Transportation Specialist

Net Area 80

Quantity 1

Adjacency Near Chief of Campus Operations and Close to Logistics Supervisor.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Secretarial workstation.Locate in same room as Supply Workstation.

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 37: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 215

Room Name Supply Workstation

Net Area 80

Quantity 1

Adjacency Locate along public corridor.Adjacent to Resident Bulk StorageEasy access to Logistics Supervisor and Housekeeping.

Floor Finish Carpet 36 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Secretarial workstation.Locate in same room as Transportation Specialist.

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 38: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 216

Room Name Resident Bulk Storage

Net Area 6300

Quantity 1

Adjacency Locate along public corridor.Adjacent to other storage rooms.Easy access to Loading Dock andService Elevators.Near Supply Workstation.

Floor Finish Sealed Concrete

Wall Finish Paint

Base Vinyl

Ceiling Finish No Ceiling

Door Type Metal DBL

Wall Construction CMU

Casework

Equipment Wire cage partition with lockable doors - 2 layers. Allow 12 SF per resident.

Arch Notes

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 82 Deg (F)

% R Humidity (Winter) -

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 39: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 217

Room Name COOP Storage

Net Area 1600

Quantity 1

Adjacency Resident Bulk Storage

Floor Finish Sealed Concrete

Wall Finish Paint

Base Vinyl

Ceiling Finish No Ceiling

Door Type Metal DBL

Wall Construction CMU

Casework

Equipment "Continuity of Operations" Storage for Emergency Response.

Arch Notes If combined with Resident Bulk Storage, provide wire cage partitions with lockable door.

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 82 Deg (F)

% R Humidity (Winter) -

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 40: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 218

Room Name Furniture Storage

Net Area 400

Quantity 1

Adjacency Resident Bulk Storage

Floor Finish Sealed Concrete

Wall Finish Paint

Base Vinyl

Ceiling Finish No Ceiling

Door Type Metal DBL

Wall Construction CMU

Casework

Equipment

Arch Notes If combined with Resident Bulk Storage, provide wire cage partitions with lockable door.

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 82 Deg (F)

% R Humidity (Winter) -

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 41: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 219

Room Name Mattress Storage

Net Area 400

Quantity 1

Adjacency Resident Bulk Storage

Floor Finish Sealed Concrete

Wall Finish Paint

Base Vinyl

Ceiling Finish No Ceiling

Door Type Metal DBL

Wall Construction CMU

Casework

Equipment

Arch Notes If combined with Resident Bulk Storage, provide wire cage partitions with lockable door.

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 82 Deg (F)

% R Humidity (Winter) -

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 42: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 220

Room Name E-Tank Storage Room

Net Area 120

Quantity 1

Adjacency Resident Bulk Storage

Floor Finish Sealed Concrete

Wall Finish Paint

Base Vinyl

Ceiling Finish No Ceiling

Door Type Metal DBL

Wall Construction CMU

Casework

Equipment

Arch Notes If combined with Resident Bulk Storage, provide wire cage partitions with lockable door.

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 82 Deg (F)

% R Humidity (Winter) -

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 43: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 221

Room Name Medical Records Storage

Net Area 500

Quantity 1

Adjacency Resident Bulk Storage

Floor Finish Sealed Concrete

Wall Finish Paint

Base Vinyl

Ceiling Finish No Ceiling

Door Type Metal DBL

Wall Construction CMU

Casework

Equipment

Arch Notes If combined with Resident Bulk Storage, provide wire cage partitions with lockable door.

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 82 Deg (F)

% R Humidity (Winter) -

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 44: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 222

Room Name Laundry Distribution Room

Net Area 120

Quantity 1

Adjacency Locate along a public corridor.Adjacent to Laundry Clean Room and Laundry Dirty Room.Easy Access to Loading Dock.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 4 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework Plam Base & Top

Equipment Include a hand sanitation station.

Arch Notes Pass-through window from Distribution Room to public corridor.Provide a door to Clean / Dirty Rooms.

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) -

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 45: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 223

Room Name Laundry Dirty Room

Net Area 400

Quantity 1

Adjacency Laundry Clean Room and Laundry Distribution Room.Easy Access to Loading Dock andService Elevators.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 4 ACT

Door Type Metal SGL

Wall Construction CMU

Casework

Equipment Storage containers provided by contractor.

Arch Notes Pass-through window from Dirty Room to Distribution Room.Provide a convenient door to Loading Dock.

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) -

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 46: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 224

Room Name Laundry Clean Room

Net Area 600

Quantity 1

Adjacency Laundry Distribution Room and Laundry Dirty Room.Easy access to Loading Dock andService Elevators.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 4 ACT

Door Type Metal SGL

Wall Construction CMU

Casework

Equipment Shelving for clean laundry provided by contractor.

Arch Notes Provide door from Clean Room to Distribution Room.Provide 2 convenient doors to Loading Dock.

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) -

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 47: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 225

Room Name Decedent Storage

Net Area 500

Quantity 1

Adjacency Resident Bulk Storage

Floor Finish Sealed Concrete

Wall Finish Paint

Base Vinyl

Ceiling Finish No Ceiling

Door Type Metal DBL

Wall Construction CMU

Casework

Equipment

Arch Notes If combined with Resident Bulk Storage, provide wire cage partitions with lockable door.

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 82 Deg (F)

% R Humidity (Winter) -

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 48: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 226

Room Name Main Trash Rooms (1 per 150 units)

Net Area 300

Quantity 3

Adjacency Trash Chutes (from above).Easy access to Loading Dock.

Floor Finish Sealed Concrete

Wall Finish Paint

Base None

Ceiling Finish No Ceiling

Door Type Metal DBL

Wall Construction CMU

Casework

Equipment Trash compactor and trash chute with fire-rated doorsat each level.Include smoke detectors in chute.

Arch Notes 1 Trash Room per 150 Units.The DBC shall describe how trash removal is addressed.May be located at First Floor or Wash-Out Level.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Self-cleaning trash chute will require water supply and drain.

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Quick Response Heads

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

May 21, 2007AFRH Gulport RFP Base Bid

Page 49: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 227

Room Name Trash Room (Includes all Living Units)

Net Area 50

Quantity 19

Adjacency Elevators, Janitor Closet, and Laundry Room.

Floor Finish Sealed Concrete

Wall Finish Paint

Base None

Ceiling Finish No Ceiling

Door Type Metal SGL

Wall Construction CMU

Casework

Equipment Self-cleaning trash chute with fire-rated doors.Recycling bins provided by Housekeeping Contractor.

Arch Notes 1 trash room per 24 residents ( Independent Living).1 trash room per 30 residents (Assisted Living).1 trash room per 12 residents (Memory Support and Long Term Care).

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control NoneCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 50: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 228

Room Name Main Recycling Room

Net Area 250

Quantity 1

Adjacency Easy Access to Loading Dock.Adjacent to Trash Room.

Floor Finish Sealed Concrete

Wall Finish Paint

Base Vinyl

Ceiling Finish No Ceiling

Door Type Metal DBL

Wall Construction CMU

Casework

Equipment Recycling containers provided by contractor.

Arch Notes Once-a-week service.

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) -

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 51: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 229

Room Name Medical Waste Holding Room

Net Area 100

Quantity 1

Adjacency Easy Access to Loading Dock.Adjacent to Trash Room and Main Recycling Room.

Floor Finish Sealed Concrete

Wall Finish Paint

Base Vinyl

Ceiling Finish No Ceiling

Door Type Metal SGL

Wall Construction CMU

Casework

Equipment Secure containers provided by contractor.

Arch Notes 90-day storage facility.For medical waste disposal.

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) -

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 52: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 230

Room Name Loading Area

Net Area 0

Quantity

Adjacency Locate along service corridor.Adjacent to Kitchen, Trash Room(s), and other service and storage areas.

Floor Finish Sealed Concrete

Wall Finish Paint

Base Vinyl

Ceiling Finish Painted GWB

Door Type OHD

Wall Construction CMU

Casework

Equipment Trash compactor in one dedicated loading space.Dock levelers at other loading spaces.Include space for 30 cubic yard dumpster, screened from view, separated from loading dock (could be in

Arch Notes 4 spaces including trash compactor, food delivery, recycling, and typical deliveries.Prefer recessed location, not enclosed, at Main Floor Level.Provide direct connection from Loading Dock to Kitchen (separate from other delivery paths).

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) -

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( )

Tele Data Special Requirements

Include motion detectors.

Sprinkler Dry Pipe System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 53: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 231

Room Name Building Engineer's Office

Net Area 120

Quantity 1

Adjacency Mechanical / Electrical Room

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 4 ACT

Door Type Metal SGL w/Side Lite

Wall Construction CMU w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.Include observation window.Provide acoustical treatment. Provide one door to corridor and one door for Mechanical / Electrical room

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 54: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 232

Room Name Engineer's Toilet

Net Area 70

Quantity 1

Adjacency Building Engineer's Office

Floor Finish Ceramic Tile

Wall Finish Ceramic Tile 1/2 Ht.

Base Ceramic

Ceiling Finish Painted GWB

Door Type Wood SGL

Wall Construction CMU w/GWB

Casework Plam Wall Base & Top

Equipment Provide complete stainless steel toilet accessories.

Arch Notes

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( x ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Privacy SetCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

May 21, 2007AFRH Gulport RFP Base Bid

Page 55: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 233

Room Name Mechanical / Electrical Room

Net Area 5000

Quantity 1

Adjacency Locate as required.Provide exterior access for maintenance.

Floor Finish Sealed Concrete

Wall Finish Paint

Base Vinyl

Ceiling Finish No Ceiling

Door Type Metal DBL

Wall Construction CMU

Casework

Equipment Mechanical and Electrical equipment (see separate description).Emergency Generator with 7-day fuel supply (safety items and emergency items).

Arch Notes 7-day survivability is required.Category 5 Hurricane requirements will influence location and layout of mech/elec equipment.2 independent electrical feeders shall be provided for redundant power.Emergency Generators are required.

Temp F (Winter) 50 Deg (F)

Temp F (Summer) 82 Deg (F)

% R Humidity (Winter) -

% R Humidity (Summer) 50%

Special HVAC Requirements

Provide access to building exterior for removal and replacement of major equipment components.

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Provide multiple floor drains.

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 56: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 301

Room Name Resident Services Chief

Net Area 224

Quantity 1

Adjacency Director's Office Entry and Admissions Officer.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.Conference table for 4 with storage unit.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( x )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 57: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 302

Room Name Main Lobby / Seating

Net Area 500

Quantity 1

Adjacency Located within Hall of Honor.

Floor Finish Stone

Wall Finish Paint & FWC

Base Stone

Ceiling Finish Painted GWB

Door Type

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Includes Seating Area for approximately 20 people.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control NoneCCTV ( x ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency power.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Dimming

Lighting Notes: Multiple room uses.

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 58: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 303

Room Name Reception Room

Net Area 800

Quantity 1

Adjacency Hall of Honor, Security Services, Main Entrance, and Concierge.

Floor Finish Carpet 36 oz

Wall Finish Paint & FWC

Base Vinyl

Ceiling Finish Painted GWB

Door Type Wood DBL

Wall Construction Metal Stud w/GWB

Casework

Equipment Memorabilia display area (floor and wall units).

Arch Notes Formal Parlor, always ready for formal events.Contains seating groups for 20 people and a grand piano.Provide separate entrance from exterior.Memorabilia displays included items from past, present, and future conflicts and AFRH history.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( x ) Access Control NoneCCTV ( x ) Cable TV ( x )

Tele Data Special Requirements

Include emergency phone and AED (electronically monitored by security).

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Dimming

Lighting Notes: Provide lighting for multiple room uses.

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 59: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 304

Room Name Concierge

Net Area 144

Quantity 1

Adjacency Locate in Main Lobby / Seating Area.

Floor Finish Stone

Wall Finish Paint & FWC

Base Stone

Ceiling Finish Painted GWB

Door Type

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Home-Style desk manned by volunteers with 2 visitor chairs with lockable storage.Assembly point for transportation scheduling.Collect flowers, dry cleaning deliveries, etc.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control NoneCCTV ( x ) Cable TV ( x )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency power.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 60: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 305

Room Name News & Vending

Net Area 150

Quantity 1

Adjacency Hall of Honor and Main Entrance.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type

Wall Construction Metal Stud w/GWB

Casework

Equipment Vending machines and news paper boxes.Provide by outside vendor microwave and ice machine.

Arch Notes Provide countertop.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Drain, water, and power required for vending machines.

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( x ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 61: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 306

Room Name Hall of Honor

Net Area 2500

Quantity 1

Adjacency Main Entrance, Reception Room, Concierge, News & Vending, and Main Street.

Floor Finish TBD

Wall Finish TBD

Base TBD

Ceiling Finish TBD

Door Type

Wall Construction Metal Stud w/GWB

Casework

Equipment Memorabilia display area (floor and wall units).Provide shelf space.Refer to Allowance 3.

Arch Notes Two-story exhibit space with overlook from above.Seating for 20 people.Recessed display cases and wall exhibits (TBD).Intended to display military memorabilia, including flags, uniforms, plaques, medals, photos, and other display materials.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control NoneCCTV ( x ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.Provide dedicated panel, and sufficient electrical lighting.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Dimming

Lighting Notes: Provide special lighting for museum-quality display. Provide display lighting for wall-mounted exhibits. Consider UV effects on exhibits.

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 62: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 307

Room Name Admissions Officer

Net Area 200

Quantity 1

Adjacency Adjacent to Move-In / Admissions Assistant and Resident Services Chief.Easy access to Director's MeetingRoom.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.Conference table with 4 chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 63: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 308

Room Name Move-In / Admissions Assistant

Net Area 120

Quantity 1

Adjacency Locate along public corridor.Adjacent to Director of Admissions and Resident Records / Information Receptionist.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL w/Side Lite

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 64: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 309

Room Name Resident Records / Information Receptionist

Net Area 300

Quantity 1

Adjacency Move-In Admissions Assistant

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment "LEKTRIEVER" system.

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 65: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 310

Room Name Admissions Social Worker

Net Area 120

Quantity 1

Adjacency Move-In / Admissions Assistant

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 66: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 311

Room Name Admissions Itinerant Office

Net Area 120

Quantity 2

Adjacency Move-In / Admissions Assistant and Resident Records / Information Receptionist.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Work table with lockable storage and 4 chairs.Moving in residents' families.Receiving people.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 67: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 312

Room Name Admissions Work / Copy Alcove

Net Area 80

Quantity 1

Adjacency Resident Records / Information Receptionist

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard workstation with files.Locate in open area

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control NoneCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 68: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 313

Room Name Shared Work / Copy Room

Net Area 160

Quantity 1

Adjacency Locate along public corridor.Adjacent to Post Office and Bank.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type

Wall Construction Metal Stud w/GWB

Casework Plam Wall Base & Top

Equipment "All-in-one" copy-fax machines (networked).Lockable storage units.

Arch Notes Shared among staff and residents.24-hour access for Residents.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( )

Tele Data Special Requirements

Provide additional telephone and data capacity.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 69: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 314

Room Name Mail Room / Post Office

Net Area 950

Quantity 1

Adjacency Along public corridor.Adjacent to Shared Work / Copy Room and Bank.Easy access to Loading Dock.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 4 ACT

Door Type

Wall Construction Metal Stud w/GWB

Casework Plam Wall Base & Top

Equipment Equipment ADA accessible and casework for full postal operations, including mailboxes.Follow USPS standards.

Arch Notes Manned by Contractor.Include area for USPS vending machines.24-hour access to post office boxes and vending.Include counter with roll-up door for USPS operator.Package drawer below with key."Knees-to-eyebrows" for mailboxes.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( )

Tele Data Special Requirements

Provide special access control per USPS requirements.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 70: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 315

Room Name Bank

Net Area 400

Quantity 1

Adjacency Locate along public corridor.Adjacent to Shared Work / Copy Room and Post Office.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Glass DBL

Wall Construction Metal Stud w/Impact Res. GWB

Casework

Equipment Equipment and casework provided by Bank Tenant.

Arch Notes Manned by Bank Tenant.2 tellers plus office.ATM located outside the bank. Accessible after hours.The DBC will coordinate installation with Bank Tenant

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( )

Tele Data Special Requirements

Run empty conduit from main telephone room for independent voice and data access.CCTV camera to be located for view of door to Bank.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 71: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 316

Room Name Security Counter / Eqpt. Room

Net Area 285

Quantity 1

Adjacency Locate at Main Entrance.Adjacent to Security Office and Interview Room.

Floor Finish Stone

Wall Finish Paint

Base Stone

Ceiling Finish ACT w/GWB Accents

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework Security Desk

Equipment Monitors, panels, and CCTV equipment.Include Resident Monitoring System.

Arch Notes Subdivide into 2 rooms with glass partitions.Dedicated HVAC service with UPS system.Work station for 2 behind counter.Include recessed emergency medical cabinet (wired to security).

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( x )

Tele Data Special Requirements

Provide additional voice and data capacity.Include Resident Monitoring System.Include AED (electronically monitored by security).

Sprinkler FM 200

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Provide receptacles on standby power system as required by users and to support security equipment.Provide UPS system with 4-hour battery backup to support security equipment.Provide standby power for HVAC service

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 72: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 317

Room Name Security Office

Net Area 170

Quantity 1

Adjacency Security Counter / Equipment Room

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL w/Side Lite

Wall Construction Metal Stud w/Impact Res. GWB

Casework

Equipment Wall mounting monitor display system with Flat screens TVs, monitors, and recording devices.No drawers on the base of manning system.

Arch Notes Accommodate "L" shaped furniture arrangements. Standard workstation with 4 chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 73: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 318

Room Name Interview Room

Net Area 120

Quantity 1

Adjacency Security Office and Security Counter / Equipment Room.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Work table with lockable storage and 4 chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 74: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 319

Room Name Housekeeping Contractor's Office

Net Area 120

Quantity 1

Adjacency Supply and Contractor / EmployeeBreak Area.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL w/Side Lite

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 75: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 320

Room Name Janitor's Closet (On Main Level)

Net Area 30

Quantity 2

Adjacency Locate along public corridor.

Floor Finish Sealed Concrete

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 4 ACT

Door Type Wood SGL

Wall Construction CMU

Casework

Equipment Mop sink and rack.

Arch Notes

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Mop sink.

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 76: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 321

Room Name Janitor's Cart Storage (On Main Level)

Net Area 100

Quantity 2

Adjacency Locate near Service Elevators.Adjacent to Janitor's Closet.

Floor Finish Sealed Concrete

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 4 ACT

Door Type Wood SGL

Wall Construction CMU

Casework

Equipment 4 Carts 3' x 4' in each room.

Arch Notes

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 82 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Key OnlyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 77: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 322

Room Name Janitor's Closet (On Residential Units Levels)

Net Area 30

Quantity 19

Adjacency Trash Room.

Floor Finish Sealed Concrete

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 4 ACT

Door Type Wood SGL

Wall Construction CMU

Casework Security Desk

Equipment Mop sink and rack.

Arch Notes Provide at least one Janitor's Closet per floor.

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 78: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 323

Room Name Contractor / Employee Break Area

Net Area 500

Quantity 1

Adjacency Locate along public corridor.Adjacent to Housekeeping Contractor's Office

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 4 ACT

Door Type Wood SGL w/Side Lite

Wall Construction Metal Stud w/Impact Res. GWB

Casework Plam Wall Base & Top

Equipment Kitchenette equipment, including refrigerator.Employee lockers.

Arch Notes Provide separate Men's and Women's Locker Areas leading to Staff Toilets.Provide full kitchenette and tables with seating for 12.Provide half-height lockers for 24 in each locker area.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( )

Tele Data Special Requirements

Do not locate CCTV cameras in Locker Areas.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 79: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 324

Room Name Contractor / Employee Toilets

Net Area 600

Quantity 1

Adjacency Contractor / Employee Break Room

Floor Finish Ceramic Tile

Wall Finish Ceramic Tile Wet Wall

Base Ceramic

Ceiling Finish Painted GWB

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework Plam Base & Top

Equipment Provide complete stainless steel toilet accessories.Provide 3 water closets (or equivalent) and 2 lavatories in each room.

Arch Notes Provide Men's and Women's Toilet Rooms.Provide 2 accessible showers in each Toilet Room.Provide automatic door openers.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( x ) Shower ( x ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control NoneCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 80: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 325

Room Name Public Toilet Rooms (On Main Level)

Net Area 3200

Quantity 1

Adjacency Locate along public corridor near major program areas.

Floor Finish Ceramic Tile

Wall Finish Ceramic Tile Wet Wall

Base Ceramic

Ceiling Finish ACT w/GWB Accents

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework Wood Base & Solid Surface Top

Equipment Provide complete stainless steel toilet accessories.Provide at least 32 accessible water closets and 16accessible lavatories.Provide automatic door openers at all Toilet Rooms

Arch Notes Provide Men's and Women's Toilet Rooms.Distribute throughout Mail Level , so that all entrances, exits, and gathering places are no more than 80 ft. from a public toilet room.Toilet rooms shall be ADA-UFAS compliant and accommodate BPV's.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( x ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control NoneCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 81: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 326

Room Name Ham Radio / Electronic Repair / Computer Shop

Net Area 400

Quantity 1

Adjacency Locate near Main Street.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 4 ACT

Door Type Wood SGL w/Side Lite

Wall Construction Metal Stud w/Impact Res. GWB

Casework Plam Base & Top

Equipment Refer to Appendix C - Ham Radio Shop Information.Provide portable antennas and "Man-Pack" radios.

Arch Notes 4 computer workstations with seating and storage units.See Appendix C for more information about antenna requirements.Provide portable antennas and man pack radios to re-establish communication if fixed antennas fail.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( x )

Tele Data Special Requirements

Provide additional voice and data capacity.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Provide receptacles on standby power to accommodate Ham Radios that can connect to theFederal communication system in an emergency.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes: Provide minimal lighting on standby power to allow room to be used in an emergency.

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 82: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 327

Room Name Wood Shop

Net Area 1500

Quantity 1

Adjacency Locate near Main Street.

Floor Finish Sealed Concrete

Wall Finish Paint

Base Vinyl

Ceiling Finish No Ceiling

Door Type Wood DBL w/Side Lite

Wall Construction Metal Stud w/GWB

Casework Plam Base & Top

Equipment Woodworking benches with stools and storage units.Woodworking equipment to be determined.Include lighting for equipment.Flammable storage cabinet / locker.

Arch Notes Provide special ventilation and acoustical treatment.Include Service desk.Subdivide into small "Amateur " shop (300 - 400 SF with hand tools and benches) and larger "Power Tool"shop.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Provide exhaust system for collection and removal of saw dust.

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( )

Tele Data Special Requirements

Include emergency phone and AED (electronically monitored by security).

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.Address power equipment for woodworking equipment.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 83: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 328

Room Name Wood Shop Storage

Net Area 300

Quantity 1

Adjacency Wood Shop

Floor Finish Sealed Concrete

Wall Finish Paint

Base Vinyl

Ceiling Finish No Ceiling

Door Type Metal DBL

Wall Construction CMU

Casework

Equipment

Arch Notes

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) -

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Include emergency phone and AED (electronically monitored by security).

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 84: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 329

Room Name Wood Shop Office

Net Area 120

Quantity 1

Adjacency Wood Shop

Floor Finish Sealed Concrete

Wall Finish Paint

Base Vinyl

Ceiling Finish No Ceiling

Door Type Wood SGL

Wall Construction CMU w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.Provide observation window into Wood Shop.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 85: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 330

Room Name Wood Shop Paint Room

Net Area 150

Quantity 1

Adjacency Wood Shop and Wood Shop Office.

Floor Finish Sealed Concrete

Wall Finish Paint

Base None

Ceiling Finish No Ceiling

Door Type Wood DBL

Wall Construction CMU

Casework

Equipment

Arch Notes Special ventilation requirements.Provide lockable closet for storage of flammable materials.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Provide dedicated, locally operated exhaust hood system.

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( x ) Cable TV ( )

Tele Data Special Requirements

Emergency phone.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

May 21, 2007AFRH Gulport RFP Base Bid

Page 86: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 331

Room Name Vending

Net Area 150

Quantity 1

Adjacency Locate along public corridor.Adjacent to Shops and Fitness Center.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type

Wall Construction Metal Stud w/Impact Res. GWB

Casework

Equipment Vending machines provided by Contractor.

Arch Notes

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control NoneCCTV ( x ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 87: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 332

Room Name Bike Shop

Net Area 225

Quantity 1

Adjacency Locate near Main Street.

Floor Finish Sealed Concrete

Wall Finish Paint

Base Vinyl

Ceiling Finish No Ceiling

Door Type Wood DBL w/Side Lite

Wall Construction CMU w/GWB

Casework

Equipment

Arch Notes Provide work benches and stools for 4 stations.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( )

Tele Data Special Requirements

Include emergency phone and AED (electronically monitored by security).

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 88: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 333

Room Name Bike Storage

Net Area 540

Quantity 1

Adjacency Locate on "Wash-Out" Level.

Floor Finish Sealed Concrete

Wall Finish Paint

Base Vinyl

Ceiling Finish No Ceiling

Door Type Metal DBL

Wall Construction CMU

Casework

Equipment

Arch Notes Provide blocking for wall-mounted racks.Include floor striping and numbering for 60 oversized 3-wheeled bikes.

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 82 Deg (F)

% R Humidity (Winter) -

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 89: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 334

Room Name Fitness Equipment Area

Net Area 2500

Quantity 1

Adjacency Locate near Main Street and Vending.Adjacent to Exercise Classroom and Fitness Storage.

Floor Finish Anti Microbial Carpet

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 4 ACT

Door Type Glass DBL

Wall Construction CMU w/GWB

Casework

Equipment Fitness equipment as required.Refer to Appendix C for a list of Recommended Equipment.Include recessed emergency medical cabinet (wired

Arch Notes Provide special ventilation and acoustical treatment.Rubber floor under major equipment.Provide wall mirrors and balanced bars.Refer to Appendix C for equipment list.Water fountain should be included.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Include drinking fountain.

Voice ( x ) Data ( x ) Audio-Video ( x ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( x )

Tele Data Special Requirements

Multiple TV outlets.Include emergency phone and AED (electronically monitored by security).

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.Provide floor outlets for fitness equipment.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 90: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 335

Room Name Fitness Center Office

Net Area 120

Quantity 1

Adjacency Fitness Center, Equipment Area, and Exercise Classroom, and Fitness Storage.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Include observation window.Standard desk and credenza with 2 visitors chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

May 21, 2007AFRH Gulport RFP Base Bid

Page 91: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 336

Room Name M & W Shower / Locker Rooms

Net Area 230

Quantity 2

Adjacency Fitness Equipment Room.

Floor Finish Rubber

Wall Finish Sanitary Wainscot

Base Ceramic

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction CMU w/GWB

Casework

Equipment Ceiling lift-track system ("voyager" style).Podiatric sink.Recumbent fast-fill tub, usable from ceiling or hydraulic lift.

Arch Notes No-wall shower (floor drain and rubber walls).Include 20 half-height lockers (no metal), benches, 4 showers (2 showers / gender), toilet, and sink. Showers and toilets should be separate from locker rooms. Showers to include a separate dressing area.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( x ) Shower ( x ) Soak Tub ( x ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( x ) Data ( ) Audio-Video ( ) Access Control Privacy SetCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Emergency phone

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 92: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 337

Room Name Assisted Unisex Bathroom

Net Area 160

Quantity 1

Adjacency Fitness Center M & W Shower / Locker Room.

Floor Finish Seamless Vinyl

Wall Finish Sanitary Wainscot

Base Integral Coved Base

Ceiling Finish Painted GWB

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework Wood Base & Solid Surface Top

Equipment Accessible bathroom with sink, toilet, and safety tub (similar to Bathease).

Arch Notes Discreet entrance for private access.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Provide toilet exhaust in accordance with Code.

Sink ( x ) Toilet ( x ) Shower ( ) Soak Tub ( x ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( x ) Data ( ) Audio-Video ( ) Access Control Privacy SetCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Include emergency phone.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 93: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 338

Room Name Exercise Classroom

Net Area 2000

Quantity 1

Adjacency Fitness Equipment Area and Fitness Storage.Near Vending Area.

Floor Finish Sprung Wood

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 4 ACT

Door Type Glass DBL

Wall Construction CMU w/GWB

Casework

Equipment Exercise Floors Mats.

Arch Notes Low-impact exercises are typical. Provide movable partition to sub-divide classroom.Provide special ventilation and acoustical treatment.Include wall mirrors and balance bars.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( x ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( x )

Tele Data Special Requirements

Include emergency phones and AED (electronically monitored by security).

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 94: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 339

Room Name Fitness / Recreation Storage

Net Area 500

Quantity 1

Adjacency Fitness Equipment and Exercise Classroom.Easy access to Loading Dock.

Floor Finish Sealed Concrete

Wall Finish Paint

Base Vinyl

Ceiling Finish No Ceiling

Door Type Wood DBL

Wall Construction CMU

Casework

Equipment Industrial metal shelving.

Arch Notes Exterior access preferred.Wire partitions multiple-compartment lockable storage.Include 60 - 80 SF alcohol storage -- locked with cardaccess Key (out of sight).

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 82 Deg (F)

% R Humidity (Winter) -

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 95: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 340

Room Name Multi-Purpose Activity Room

Net Area 3400

Quantity 1

Adjacency Located near Main Street.Adjacent to Dining Room.Near Prefunction, Outside Patio, and Exercise Classroom.

Floor Finish Marble Floor

Wall Finish Paint & FWC

Base Vinyl

Ceiling Finish ACT w/GWB Accents

Door Type Wood DBL w/Side Lite

Wall Construction Metal Stud w/Impact Res. GWB

Casework

Equipment Provide moveable partition between Multi-Purp Activity Room and Dining Room for expansion during major events w/soundproofing.Provide storage for tables, chairs, etc.

Arch Notes Hi-ceiling, square shape, column-free space with flat floor.Provide movable partition to sub-divide room into 2 spaces.Provide special ventilation and acoustical treatment,Small raised stage with ramp.Provide dance floor (size TBD)

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( x ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( x )

Tele Data Special Requirements

Include movie projection system and adequate microphone equipment.Include emergency phone and AED (electronically monitored by security).Include recessed emergency medical cabinet (wired to security).

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Provide receptacles on standby power to allow room to be used in an emergency.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Dimming

Lighting Notes: Provide lighting on standby power to allow room to be used in an emergency.Provide special theatrical lighting for stage area.

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 96: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 341

Room Name Lounge

Net Area 1800

Quantity 1

Adjacency Locate along Main Street.Adjacent to Smokehouse / BBQ Equipment Storage , Outside Patio, Bowling, Multi-Purpose Activity Room and Dining Room.

Floor Finish Wood

Wall Finish Paint & FWC

Base Wood

Ceiling Finish ACT w/GWB Accents

Door Type Wood DBL w/Side Lite

Wall Construction Metal Stud w/GWB

Casework Wood Base & Solid Surface Top

Equipment Bar equipment as required.Common kitchen and hood ventilation for grilling.Include recessed emergency medical cabinet (wired to security).

Arch Notes Provide bar tables and seating for 25 people.Provide special ventilation and acoustical treatment.Floor finish should be different at bar area.Include anti-fatigue mats behind bar.Include storage area as required.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Floor Drain and sink placed at bar service area.

Voice ( x ) Data ( x ) Audio-Video ( x ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( x )

Tele Data Special Requirements

Include emergency phone and AED (electronically monitored by security).

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Dimming

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 97: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 342

Room Name Smokehouse / BBQ Equipment Storage

Net Area 150

Quantity 1

Adjacency Locate near Lounge, Game Room and Bowling.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 4 ACT

Door Type Glass SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment Include recessed emergency medical cabinet (wired to security).Provide pass-through window from the bar.Not directly attached to building.

Arch Notes Provide tables and seating for 12.Provide separate special ventilation and acoustical treatment.Available for staff and residents.Glass walls and ceiling fan (greenhouse type, outdoorfeeling).Provide fireplace.Exterior access desired.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) -

% R Humidity (Summer) 50%

Special HVAC Requirements

Provide confinement ventilation system with 100% exhaust of space.

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control NoneCCTV ( x ) Cable TV ( x )

Tele Data Special Requirements

Emergency phone.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 98: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 343

Room Name Game Room

Net Area 1100

Quantity 1

Adjacency Locate near Main Street.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish ACT w/GWB Accents

Door Type Glass DBL

Wall Construction Metal Stud w/Impact Res. GWB

Casework Wood Base & Solid Surface Top

Equipment Pool table and card tables.Lockable storage units.Table-top shuffle board.

Arch Notes Provide tables and seating for 24.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( x )

Tele Data Special Requirements

Include emergency phone and AED (electronically monitored by security).

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 99: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 344

Room Name Meditation Room

Net Area 600

Quantity 1

Adjacency Locate in quiet area near Main Street.

Floor Finish Carpet 36 oz

Wall Finish Paint & FWC

Base Vinyl

Ceiling Finish Painted GWB

Door Type Wood DBL w/Side Lite

Wall Construction Metal Stud w/GWB

Casework

Equipment 8 pews for 30 to 40 people.Lectern with microphone.

Arch Notes Provide special ventilation and acoustical treatment.Inter-faith services.Multi-purpose room for group settings.Quiet room.Provide "Open-Flame" vitrine.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( x ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Dimming

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 100: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 345

Room Name Recreation Activities Supervisor

Net Area 120

Quantity 1

Adjacency Locate near Main Street and recreational areas.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( x )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 101: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 346

Room Name Program Office

Net Area 100

Quantity 4

Adjacency Locate off public corridor.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk with 2 visitor chairs.Function as reception for recreation spaces.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( x )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 102: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 347

Room Name Recreation Therapy Supervisor

Net Area 120

Quantity 1

Adjacency Near to Therapy offices.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitors chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( x )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

May 21, 2007AFRH Gulport RFP Base Bid

Page 103: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 348

Room Name Recreation Therapy Workstations

Net Area 100

Quantity 2

Adjacency Therapeutic Recreational Supervisor, AL, MS, and L-TC Units.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Workstations

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( x )

Tele Data Special Requirements

Provide additional voice and data capacity.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 104: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 349

Room Name Indoor Shuffle Board / Bocce Ball Court

Net Area 2160

Quantity 1

Adjacency Located near Main Street.Optional location in "Wash-Out" Level.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish ACT w/GWB Accents

Door Type Wood DBL w/Side Lite

Wall Construction CMU w/GWB

Casework

Equipment Shuffle Board equipment as required.

Arch Notes

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( )

Tele Data Special Requirements

Include emergency phone and AED (electronically monitored by security).

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 105: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 350

Room Name Resident Computer Lab

Net Area 600

Quantity 1

Adjacency Locate near Main Street.Adjacent to Electronic Repair Room, Listening Room / Multi-Functional, 24-Hour Resident Training Room, and Library.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 4 ACT

Door Type Wood SGL w/Side Lite

Wall Construction Metal Stud w/GWB

Casework

Equipment Computers.

Arch Notes Computer workstations and seating for 8.Teaching classroom.Alternate EOC location.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( )

Tele Data Special Requirements

Include emergency phone and AED (electronically monitored by security).

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Dimming

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 106: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 351

Room Name 24 Hour Internet and Game Room

Net Area 720

Quantity 1

Adjacency Locate near Main Street.Adjacent to Resident Computer Lab and Electronic Repair Room.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 4 ACT

Door Type Wood DBL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Computer workstations and seating for 16.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( )

Tele Data Special Requirements

Include emergency phone and AED (electronically monitored by security).

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Dimming

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 107: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 352

Room Name Listening / Multi-Function Room

Net Area 225

Quantity 1

Adjacency Resident Computer Lab and 24-Hour Resident Training Room.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 4 ACT

Door Type Wood DBL

Wall Construction Metal Stud w/GWB

Casework

Equipment TV's, DVD's, and music equipment.

Arch Notes "Softest" room in building.Provide acoustical treatment.Should accommodate up to 6 people.Library-type storage.Piano - record music.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( )

Tele Data Special Requirements

Include emergency phone and AED (electronically monitored by security).

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Dimming

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 108: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 353

Room Name Emergency Supply Alcove

Net Area 110

Quantity 1

Adjacency Locate near Multi-Purpose ActivityRoom and Dining Room.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Open storage area for crash cart.Cart with tanks.Mouth-to-Mouth resuscitation equipment.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 109: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 354

Room Name Bowling

Net Area 2750

Quantity 1

Adjacency Lounge, Smokehouse / BBQ Equipment Storage and Game Room.Near Vending.

Floor Finish Wood

Wall Finish Paint

Base Wood

Ceiling Finish 2 x 4 ACT

Door Type Glass DBL

Wall Construction Metal Stud w/Impact Res. GWB

Casework

Equipment Bowling equipment as required.

Arch Notes 4 lanes.End lane should be accessible for mobility impaired.Fully automatic system and scoring.This space should be isolated for sound control.Special humidity control.Include unisex accessible toilet room.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( x ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( x )

Tele Data Special Requirements

Include emergency phone and AED (electronically monitored by security).

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 110: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 355

Room Name Thrift Shop

Net Area 400

Quantity 1

Adjacency Locate on "Wash-Out" Level.

Floor Finish Sealed Concrete

Wall Finish Paint

Base None

Ceiling Finish No Ceiling

Door Type Metal DBL

Wall Construction CMU

Casework

Equipment

Arch Notes Storage and display of resident items sold on a monthly basis ("garage sale").

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 111: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 356

Room Name Hair Care / Salon

Net Area 260

Quantity 1

Adjacency Locate along Main Street.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 4 ACT

Door Type Glass SGL

Wall Construction Metal Stud w/GWB

Casework Plam Base & Top

Equipment Hair Care Salon equipment provided by operator.Include 4 stations.

Arch Notes Space should be divided as follows: 240 SF for 4 stations and 20 SF for locked storage and shelving.Include handwashing station.Include hair washing station.Provide wall mirrors.Provide special ventilation.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( x )

Tele Data Special Requirements

Include emergency phone and AED (electronically monitored by security).

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.Provide sufficient power for hair dryers and equipment.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 112: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 357

Room Name Library + DVD Room

Net Area 2000

Quantity 1

Adjacency Locate along Main Street.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish ACT w/GWB Accents

Door Type Glass DBL

Wall Construction Metal Stud w/GWB

Casework

Equipment Main Desk

Arch Notes Provide library shelving for books.Tables and seating for 20 to 30.Provide small storage room (lockable) with shelving (10' x 10').

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( x )

Tele Data Special Requirements

Include emergency phone and AED (electronically monitored by security).

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes: Provide additional lighting in reading areas.

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 113: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 358

Room Name Exchange PX

Net Area 2000

Quantity 1

Adjacency Locate along Main Street.Easy access to Loading Dock.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 4 ACT

Door Type Glass DBL

Wall Construction Metal Stud w/GWB

Casework

Equipment Store fixtures to be provided by tenant (AAFES).

Arch Notes Small grocery store.Provide separate electric meter.Includes rear lockable storage room (size TBD).

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control NoneCCTV ( x ) Cable TV ( )

Tele Data Special Requirements

Provide empty conduit from main switch room for independent voice and data access.CCTV camera to be located for view of door to Exchange PX.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Additional power for tenant equipment.Refrigerator on emergency power.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 114: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 359

Room Name Multi-Function Media Room

Net Area 1000

Quantity 1

Adjacency Locate along Main Street and Lounge.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood DBL

Wall Construction Metal Stud w/Impact Res. GWB

Casework Wood Base & Solid Surface Top

Equipment Projector, projection screen, and AV systems.

Arch Notes Provide offset theater-style seating for up to 100 people to watch movies, etc.Provide special ventilation and acoustical treatment.Wall treatment with wheelchair protection.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Floor drain and sink placed at bar service area.

Voice ( x ) Data ( x ) Audio-Video ( x ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( x )

Tele Data Special Requirements

Include emergency phone.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.Provide additional power for AV equipment as required.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Dimming

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 115: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 360

Room Name Spiro's Canteen

Net Area 700

Quantity 1

Adjacency Locate along Main Street.

Floor Finish VCT

Wall Finish Sanitary Wainscott

Base Integral Coved Base"

Ceiling Finish 2 x 4 ACT

Door Type

Wall Construction Metal Stud w/Impact Res. GWB

Casework Wood Base & Solid Surface Top

Equipment Provided by vendor.

Arch Notes Provide 6 tables and seating for 20 to 25 people.Provide special ventilation and acoustical treatment.Self-service café.Open area.Late night operation.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Handwashing sink placed on countertop.Drain and water supply to beverage dispensing equipment (approx. 4 machines).

Voice ( x ) Data ( ) Audio-Video ( ) Access Control NoneCCTV ( x ) Cable TV ( x )

Tele Data Special Requirements

Include emergency phone and AED (electronically monitored by security).

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Provide additional power for beverage dispensing machines.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc): 10

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 116: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 361

Room Name Painting and Ceramics (Wet)

Net Area 600

Quantity 1

Adjacency Locate along Main Street.Adjacent to Crafts (Dry), Sewing Room, and Resident Art Display Room.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 4 ACT

Door Type Wood DBL w/Side Lite

Wall Construction Metal Stud w/GWB

Casework Wood Base & Solid Surface Top

Equipment Arts equipment as required.Provide separate room for kilns. (100 SF). Locate with special exhaust ventilation.Include 2 - 3 stations with hoods for localized table-

Arch Notes Provide a door to open directly to Crafts (Dry).Shelving for storing items.Tables and seating for 12.Provide 2 service sinks and worktop.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Provide 2 sinks with sano-trap.

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( )

Tele Data Special Requirements

Include emergency phone and AED (electronically monitored by security).

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.Provide additional power for electric kilns.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 117: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 362

Room Name Crafts (Dry)

Net Area 600

Quantity 1

Adjacency Locate along Main Street.Adjacent to Painting and Ceramics (Wet), Sewing Room, and Resident Art Display Room.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 4 ACT

Door Type Wood DBL w/Side Lite

Wall Construction Metal Stud w/GWB

Casework Wood Base & Solid Surface Top

Equipment Crafts equipment as required.

Arch Notes Provide a door to open directly to Arts (Wet).Shelving for storing items.Tables and seating for 20.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( x )

Tele Data Special Requirements

Include emergency phone and AED (electronically monitored by security).

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 118: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 363

Room Name Sewing Room

Net Area 600

Quantity 1

Adjacency Locate along Main Street.Adjacent to Painting and Ceramics (Wet), Crafts (Dry), and Resident Art Display Room.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 4 ACT

Door Type Wood DBL w/Side Lite

Wall Construction Metal Stud w/GWB

Casework Wood Base & Solid Surface Top

Equipment Sewing equipment as required.

Arch Notes Tables and seating for 12 with storage units.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( x )

Tele Data Special Requirements

Include emergency phone and AED (electronically monitored by security).

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 119: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 364

Room Name Puzzle Room

Net Area 180

Quantity 1

Adjacency Assisted Living

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL w/Side Lite

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Tables and seating for 12 with storage units.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Include emergency phone and AED (electronically monitored by security).

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 120: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 365

Room Name Resident Art Display Room

Net Area 500

Quantity 1

Adjacency Locate along Main Street.Adjacent to Painting and Ceramics (Wet), Crafts (Dry), and Sewing Room.

Floor Finish Carpet 36 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish ACT w/GWB Accents

Door Type Glass DBL

Wall Construction Metal Stud w/GWB

Casework

Equipment Provide floor and wall display cases (lockable and accessible).

Arch Notes

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( )

Tele Data Special Requirements

Include emergency phone and AED (electronically monitored by security).

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 121: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 366

Room Name Volunteer Coordinator Office

Net Area 120

Quantity 1

Adjacency Volunteer Home Room

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 122: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 367

Room Name Volunteer Home Room

Net Area 600

Quantity 1

Adjacency Locate along public corridor.Adjacent to Main Street functions.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL w/Side Lite

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Provide tables and seating for 12 with storage units.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( x )

Tele Data Special Requirements

Include emergency phone and AED (electronically monitored by security).

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 123: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 368

Room Name Volunteer Storage

Net Area 400

Quantity 1

Adjacency Volunteer Home Room

Floor Finish Sealed Concrete

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood DBL

Wall Construction Metal Stud w/Impact Res. GWB

Casework

Equipment

Arch Notes Hi-density pallet storage for Holiday decorations, etc.Manual operation "sliding doors."

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) -

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 124: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 369

Room Name Toilet Rooms

Net Area 400

Quantity 1

Adjacency Near to the Volunteer Home Room.

Floor Finish Ceramic Tile

Wall Finish Ceramic Tile Wet Wall

Base Ceramic

Ceiling Finish Painted GWB

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework Plam Base & Top

Equipment Provide complete stainless steel toilet accessories.

Arch Notes Provide Men's and Women's Toilet Rooms.Provide automatic door openers.Provide 3 water closets (or equivalent) and 2 lavatories in each Toilet Room.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( x ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control NoneCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 125: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 370

Room Name Contractor Services Representative / Janitorial Servi

Net Area 120

Quantity 1

Adjacency Housekeeping Contractor's Office

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 126: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 371

Room Name Dining Services Administrator

Net Area 120

Quantity 1

Adjacency Kitchen and Dining Room.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 127: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 372

Room Name Prefunction

Net Area 1000

Quantity 1

Adjacency Locate along public corridor.Adjacent to Service Line.Easy access to Public Toilets.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish ACT w/GWB Accents

Door Type

Wall Construction Metal Stud w/GWB

Casework

Equipment Memorabilia display area (floor and wall units).

Arch Notes Provide seating for "people-watching".Open area.20 - 30 seats.Memorabilia displays included items from past, present, and future conflicts and AFRH history.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( x )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Dimming

Lighting Notes: Provide lighting to allow for multiple room uses.

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 128: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 373

Room Name Dining and Assisted Dining

Net Area 7700

Quantity 1

Adjacency Prefunction, Kitchen, Multi-Purpose Activity Room, Outside Patio, and Public Toilets.

Floor Finish VCT

Wall Finish Wainscott"

Base Vinyl

Ceiling Finish ACT w/GWB Accents

Door Type Glass DBL

Wall Construction CMU w/GWB

Casework

Equipment Provide moveable partition between Dining Room and Multi-Purpose Activity Room for expansion during major events.Dining equipment as required.

Arch Notes Provide separate Assisted Dining Area with separate entrance and a separate service line.Estimated seating for 275 (28 SF / person). NO ROUND TABLES.Provide variety of seating (individuals, doubles, and groups of 6-12) with adjustable table heights.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( x ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( x )

Tele Data Special Requirements

Include emergency phone and AED (electronically monitored by security).Include recessed emergency medical cabinet (wired to security).Provide AV System for major events.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Provide minimal receptacles on standby power to allow room to be used in an emergency.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Dimming

Lighting Notes: Provide l lighting on standby power to allow room to be used in an emergency.

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 129: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 374

Room Name Service Line

Net Area 2000

Quantity 1

Adjacency Kitchen and Dining.

Floor Finish Sheet Vinyl

Wall Finish Paint

Base Integral Coved Base"

Ceiling Finish Painted GWB

Door Type

Wall Construction CMU w/GWB

Casework

Equipment Stainless steel service line equipment.

Arch Notes "Functionally accessible for older people."Secure sanitized areas from Dining Room for after-hours operation.ADA-Compliant.36-foot overall length (approx.).Half-height anti-fungal durable / washable hard surface.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control NoneCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Provide receptacles on standby power to allow for fully functional kitchen service.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes: Provide lighting on standby power to allow for fully functional kitchen service.

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 130: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 375

Room Name Assisted Dining Service Line

Net Area 300

Quantity 1

Adjacency Assisted Dining

Floor Finish Sheet Vinyl

Wall Finish Paint

Base Vinyl

Ceiling Finish Painted GWB

Door Type

Wall Construction CMU w/GWB

Casework

Equipment Stainless steel service line equipment.

Arch Notes "Functionally accessible for older people."ADA compliant.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control NoneCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Provide receptacles on standby power to allow for fully functional kitchen service.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching:

Lighting Notes: Provide lighting on standby power to allow for fully functional kitchen service.

May 21, 2007AFRH Gulport RFP Base Bid

Page 131: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 376

Room Name Kitchen

Net Area 8000

Quantity 1

Adjacency Service Lines and Loading Dock.Provide direct connection to MS Service Line (maybe dedicated elevator) for food delivery and scullery service.

Floor Finish Sheet Vinyl

Wall Finish Sanitary Wainscot

Base Vinyl

Ceiling Finish Painted GWB

Door Type Wood DBL

Wall Construction CMU w/GWB

Casework Plam Wall Base & Top

Equipment Kitchen equipment as required - refer to Section K - Dining and Food Service.Refer to Appendix C - List of Existing Kitchen Equipment and Plan of Existing Kitchen.

Arch Notes Includes Offices, Cold Stores, Dry Stores, EmergencyStores, and Staff Lockers.Full-service common kitchen menus - refer to Appendix C for examples.Catering (10-300) up to 1 per week.7-10 day food storage.Serves 1,200 meals per day (3 servings).

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 82 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Provide dedicated kitchen make-up air and exhaust systems sized and configured in accordance with Code.

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Provide hand washing and service sinks as required.

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Provide receptacles on standby power to allow for fully functional kitchen service.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes: Provide lighting on standby power to allow for fully functional kitchen service.

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 132: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 377

Room Name Kitchen Staff Men's Toilet

Net Area 300

Quantity 1

Adjacency Kitchen

Floor Finish Ceramic Tile

Wall Finish Ceramic Tile 1/2 Ht.

Base Ceramic

Ceiling Finish Painted GWB

Door Type Wood SGL

Wall Construction CMU w/GWB

Casework Plam Base & Top

Equipment Provide complete stainless steel toilet accessories.

Arch Notes Provide 3 water closets (or equivalent) and 2 lavatories in each Toilet Room.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( x ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Privacy SetCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 133: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 378

Room Name Kitchen Staff Women's Toilet

Net Area 300

Quantity 1

Adjacency Kitchen

Floor Finish Ceramic Tile

Wall Finish Ceramic Tile 1/2 Ht.

Base Ceramic

Ceiling Finish Painted GWB

Door Type Wood SGL

Wall Construction CMU w/GWB

Casework Plam Base & Top

Equipment Provide complete stainless steel toilet accessories.

Arch Notes Provide 3 water closets (or equivalent) and 2 lavatories in each Toilet Room.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( x ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Privacy SetCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 134: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 379

Room Name Independent Living 1 Units

Net Area 450

Quantity 282

Adjacency See Adjacency Diagram for Typical Independent Living Level.

Floor Finish Anti Microbial Carpet

Wall Finish Paint

Base Vinyl

Ceiling Finish Painted GWB

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework Wood Wall Base & Solid Surface Top

Equipment Full kitchenette with sink and area for "mini" refrigerator and microwave oven.Include "lock boxes" for valuables (6" x 12" - Type TBD).

Arch Notes Includes full accessible bath with sink, toilet and shower.Provide rubber floor and "sanitary" walls in bathroom for wash down.Provide pull-down bars at toilet, and standard grab bars elsewhere as required.Provide connecting door for 10% of units.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( x ) Shower ( x ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Provide fully-waterproofed floor in bathroom.Provide separate floor drains in shower and bathroom floor.

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( x )

Tele Data Special Requirements

Provide 2 telephone outlets (on opposite walls) and 1 data connection with 2 data lines.Provide 1 emergency device in bathroom and 2 devices in living area connected to the Resident Monitoring System (including Wellness Center Check-In Button).

Sprinkler Quick Response Heads

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Provide one duplex outlet in each room on standby power circuit.Provide circuit for personal battery powered vehicle charging.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes: Provide indirect lighting in living area.Provide one permanently installed lighting fixture in the living unit and one permanently installed lighting fixture in the bathroom on standby power.

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 135: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 380

Room Name IL1 Day Room / Lounge

Net Area 250

Quantity 12

Adjacency Elevator Lobby and Resident Corridor.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish Painted GWB

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework Plam Wall Base & Top

Equipment

Arch Notes 1 unit serves 24 residents.Provide TV, couches and chairs, and 2 card tables with 4 chairs each.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( x )

Tele Data Special Requirements

Include emergency phone and AED (electronically monitored by security).

Sprinkler Dry Pipe System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 136: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 381

Room Name IL1 Laundry Room

Net Area 100

Quantity 12

Adjacency Elevators, Janitor Closet, and Trash Room.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type

Wall Construction Metal Stud w/GWB

Casework Plam Wall Base & Top

Equipment Commercial-grade Washer / Dryer and deep stackable front load. ADA-accessible sink.Provide Industrial-grade solid shelving.Warpool system for drying and "steaming" equipment

Arch Notes 1 Laundry Room per 24 residents.Include table for folding laundry, clothes rod, and 2 chairs.Provide special ventilation and acoustical treatment.Water temperature booster in laundry rooms for one of washer --controlled by staff.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Provide utility sink.Provide special oversized floor drain with gooseneck faucet to accommodate washer overflow.

Voice ( Data ( ) Audio-Video ( ) Access Control NoneCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 137: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 382

Room Name IL1 Public Toilet Rooms (M & W)

Net Area 70

Quantity 24

Adjacency IL1 Day Room / Lounge and Independent Living Units.

Floor Finish Ceramic Tile

Wall Finish Ceramic Tile 1/2 Ht.

Base Ceramic

Ceiling Finish Painted GWB

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework Plam Base & Top

Equipment Provide complete stainless steel toilet accessories.

Arch Notes Fully ADA accessible water closet and sink.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( x ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Privacy SetCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 138: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 401

Room Name WC Reception / Check In

Net Area 140

Quantity 1

Adjacency Locate along public corridor on Main Level.Adjacent to Waiting Area and Medical Records.Direct access to emergency vehicle drop-off.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Glass DBL

Wall Construction Metal Stud w/GWB

Casework Reception Desk

Equipment Provide standard hospital floor area wall bumpers with integral corner guards in waiting areas and corridors.Provide publication niche for magazine/brochure

Arch Notes Provide work surface with area to charge PDA's, etc.Accessible for Battery Powered Vehicles (BPV).NOTE: Internal corridors in wellness center are 8' wide typical.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 139: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 402

Room Name WC Waiting Area

Net Area 280

Quantity 1

Adjacency WC Reception / Check In and Exam Rooms.

Floor Finish Carpet 32 oz

Wall Finish Paint & FWC

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Glass DBL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Seating for 15 plus space for BPV (40 people max.)

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control NoneCCTV ( x ) Cable TV ( x )

Tele Data Special Requirements

Provide A.E.D and emergency phone.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 140: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 403

Room Name Toilet / Specimen Room

Net Area 70

Quantity 2

Adjacency WC Waiting Area and Exam Rooms.

Floor Finish Ceramic Tile

Wall Finish Ceramic Tile 1/2 Ht.

Base Ceramic

Ceiling Finish Painted GWB

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment Provide complete stainless steel toilet accessories.

Arch Notes Provide one ADA accessible sink and toilet in each Toilet / Specimen Room.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( x ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Privacy SetCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 141: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 404

Room Name Clinical Supervisor

Net Area 200

Quantity 1

Adjacency Office Assistant, MD Office and Clinical Administrator.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.Conference Table for 4 with storage unit.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Provide wireless conference phone.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 142: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 405

Room Name Office Assistant

Net Area 80

Quantity 1

Adjacency Clinical Supervisor

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Secretarial workstation.Function as reception for Director of Health Services.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 143: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 406

Room Name Clinical Administrator

Net Area 120

Quantity 1

Adjacency Clinical Supervisor and MD Office.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 144: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 407

Room Name MD Office

Net Area 120

Quantity 1

Adjacency Exam Rooms and WC Staff Offices.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 145: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 408

Room Name Geriatric Nurse Practitioner

Net Area 120

Quantity 1

Adjacency Exam Rooms and WC Staff Offices.Easy access from internal corridor

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 146: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 409

Room Name Central Appointment Office

Net Area 120

Quantity 1

Adjacency WC Staff Offices

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 147: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 410

Room Name Exam Room

Net Area 120

Quantity 1

Adjacency WC Waiting Area

Floor Finish Seamless Non Glare

Wall Finish Paint

Base Integral Coved Base

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework Ptd Mtl Base & Wall w/solid surface top

Equipment Exam Room equipment (TBD).See Appendix C for Exam Room information.

Arch Notes Provide handwashing station, locked storage units, plus writing desk.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Provide handwashing sink.

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes: Task lighting.

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 148: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 411

Room Name Bariatric Exam Room

Net Area 120

Quantity 1

Adjacency Exam Room

Floor Finish Seamless Non Glare

Wall Finish Paint

Base Integral Coved Base

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework Ptd Mtl Base & Wall w/solid surface top

Equipment Bariatric Exam Room equipment (TBD).See Appendix C for Exam Room information.

Arch Notes Provide handwashing station, locked storage units, plus writing desk.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Provide handwashing sink.

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes: Task lighting.

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 149: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 412

Room Name Triage / Exam Room

Net Area 120

Quantity 1

Adjacency Exam RoomsClose to Waiting Room.

Floor Finish Seamless Non Glare

Wall Finish Paint

Base Integral Coved Base

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework Ptd Mtl Base & Wall w/solid surface top

Equipment Exam Room equipment as (TBD).Ceiling-mounted exam light.

Arch Notes Provide handwashing station, locked storage units, plus writing desk.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Provide handwashing sink.

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Include emergency phone and AED (electronically monitored by security).

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 150: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 413

Room Name Phlebotomy / Exam Room

Net Area 120

Quantity 1

Adjacency WC Waiting Area

Floor Finish Seamless Vinyl

Wall Finish Paint

Base Integral Coved Base

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework Ptd Mtl Base & Wall w/solid surface top

Equipment Exam Room equipment (TBD).Special medical-type casework for Phlebotomy equipment.

Arch Notes Includes handwashing station, lockable storage units,plus writing desk.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Provide handwashing sink.

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 151: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 414

Room Name Centrifuge Room

Net Area 70

Quantity 1

Adjacency Exam Room

Floor Finish Seamless Vinyl

Wall Finish Paint

Base Integral Coved Base

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework Ptd Mtl Base & Wall w/solid surface top

Equipment Undercounter refrigerator and handwashing sink.

Arch Notes Provide lockable door.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Provide handwashing sink.

Voice ( Data ( ) Audio-Video ( ) Access Control Key OnlyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 152: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 415

Room Name Podiatry / Exam Room

Net Area 150

Quantity 1

Adjacency WC Waiting Area

Floor Finish Seamless Non Glare

Wall Finish Paint

Base Integral Coved Base

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework Ptd Mtl Base & Wall w/solid surface top

Equipment Exam Room equipment (TBD), including Podiatric sink.

Arch Notes Includes handwashing station, lockable storage units,plus writing desk.Additional casework near Podiatric sink.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Includes handwashing station and podiatric sink with floor drain.

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 153: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 416

Room Name WC Medication Distribution

Net Area 120

Quantity 1

Adjacency WC ReceptionEasy access from public corridor.

Floor Finish Seamless Vinyl

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework Plam Wall Base & Top

Equipment Full-size refrigerator.

Arch Notes Locked, secure room.Provide handwashing station and locked storage unitsSpecial locked cabinets for narcotics and drugs.Include drop-off window

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Provide handwashing sink.

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Provide standby power for refrigerators and freezers.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes: Provide standby power for lighting.

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 154: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 417

Room Name Dental and Eye Clinic Waiting Area

Net Area 200

Quantity 1

Adjacency Reception, Dental Area, and Eye Clinic Area.

Floor Finish Carpet 36 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Glass DBL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Seating for 8 plus space for BPV.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

P

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control NoneCCTV ( ) Cable TV ( x )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 155: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 418

Room Name Dental Reception

Net Area 100

Quantity 1

Adjacency Dental and Eye Clinic Waiting Area.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework Reception Desk

Equipment

Arch Notes

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access ControlCCTV ( ) Cable TV ( x )

Tele Data Special Requirements

Sprinkler

Fire Suppression Notes

Include on Emergency Power Genset

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: Avg Maintained Level (fc):

Fixture Types: Switching:

Lighting Notes:

May 21, 2007AFRH Gulport RFP Base Bid

Page 156: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 419

Room Name Dentist's Office

Net Area 120

Quantity 1

Adjacency Dental Reception, Dental Lab, and Dental Equipment.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 157: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 420

Room Name Dental Medical Files

Net Area 140

Quantity 1

Adjacency Dental Reception

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment Filing cabinets.

Arch Notes

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 158: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 421

Room Name Dental Chairs

Net Area 200

Quantity 3

Adjacency Dentist's Office and Dental Reception.

Floor Finish Seamless Non Glare

Wall Finish Paint

Base Integral Coved Base

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework Wood Dental Cabinetry"

Equipment Fixed dental equipment as required.See Appendix C - List of Medical Equipment for Dental Area.

Arch Notes Extra Room for chair, doctor, and BPV.Provide lockable storage cabinets.Provide small handwashing sink with counter space and drawers.Lots of indirect, color corrected lighting.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 159: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 422

Room Name Sterilization Room

Net Area 120

Quantity 1

Adjacency Dental Lab and Dentist's Office.

Floor Finish Seamless Non Glare

Wall Finish Paint

Base Integral Coved Base

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework Wood Dental Cabinetry"

Equipment

Arch Notes Sink large enough to drain.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 160: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 423

Room Name X-Ray Station

Net Area 25

Quantity 1

Adjacency Dental Chair and Sterilization Room.

Floor Finish Seamless Vinyl

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment X-Ray machine.

Arch Notes

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 161: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 424

Room Name Supply Closet

Net Area 100

Quantity 1

Adjacency Dental Lab and Dental Chairs.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 4 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework

Equipment Shelving.

Arch Notes

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Key OnlyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 162: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 425

Room Name Dental Lab

Net Area 100

Quantity 1

Adjacency Dentist's Office, Supply Closet, and Sterilization Room.

Floor Finish Seamless Non Glare

Wall Finish Paint

Base Integral Coved Base

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework Wood Dental Cabinetry"

Equipment Dental Lab equipment as required.

Arch Notes Provide counter space and drawers.Provide natural gas for denture making (left and right hand).Provide small handwashing sink.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 163: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 426

Room Name Dental Equipment

Net Area 25

Quantity 1

Adjacency Supply Closet.

Floor Finish Seamless Non Glare

Wall Finish Paint

Base Integral Coved Base

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework Wood Dental Cabinetry"

Equipment

Arch Notes

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 164: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 427

Room Name Dental Break Room

Net Area 100

Quantity 1

Adjacency Supply Closet

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework Plam Wall Base & Top

Equipment Ice machine and small refrigerator.

Arch Notes Coat closet.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Small handwashing sink with counter space and drawers.

Voice ( Data ( ) Audio-Video ( ) Access Control NoneCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 165: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 428

Room Name Eye Clinic / Fitting Room

Net Area 200

Quantity 1

Adjacency Dental and Eye Clinic Waiting Room and Optometrist Office.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood DBL

Wall Construction Metal Stud w/GWB

Casework Plam Wall Base & Top

Equipment Optometric equipment as required.Refer to Appendix C - List of Medical Equipment for the Eye Clinic.

Arch Notes Provide enough space for cabinets and BPV's turning radius in room.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Provide handwashing sink.

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 166: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 429

Room Name Eye Clinic Work Room

Net Area 80

Quantity 2

Adjacency Eye Clinic Fitting Room.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Secretarial workstation.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control NoneCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 167: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 430

Room Name Optometrist / Ophthalmologist Office

Net Area 200

Quantity 1

Adjacency Eye Clinic Fitting Room

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment Optometric equipment as required.See Appendix C - List of Medical Equipment for the Eye Clinic.

Arch Notes Standard desk and credenza with 2 visitor's chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 168: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 431

Room Name WC Conference Room / Alt. EOC

Net Area 400

Quantity 1

Adjacency Exam Rooms and MD Office.

Floor Finish Carpet 32 oz

Wall Finish Paint & FWC

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL w/Side Lite

Wall Construction Metal Stud w/GWB

Casework

Equipment Motorized projection screen (recessed automatic), and wall-mounted whiteboard (9' x 8').Provide emergency cabinet.

Arch Notes Large conference table and seating for 12.Space for social workers and group sessions.Provide acoustical treatment.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( x )

Tele Data Special Requirements

Provide wireless conference phone.Include additional voice and data capacity.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Dimming

Lighting Notes: Special lighting for projection purposes.

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 169: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 432

Room Name Medical Records

Net Area 2000

Quantity 1

Adjacency WC Reception / Check-In

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment "LEKTRIEVER" system or similar.

Arch Notes Average length of record keeping: 10 years.Increase structural support for hi-density filing system60 filing cabinets.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 170: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 433

Room Name Medical Chart Alcove

Net Area 24

Quantity 1

Adjacency Medical Records

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Open storage area for medical charts.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 171: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 434

Room Name WC Mobility Alcove

Net Area 60

Quantity 1

Adjacency WC Waiting Area

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework

Equipment

Arch Notes Open storage area for wheelchairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access ControlCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 172: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 435

Room Name WC Clean Linen

Net Area 120

Quantity 1

Adjacency Exam Rooms

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment Provide Industrial-grade solid shelving.

Arch Notes Storage for "full" and "empty" containers, 8-12 "E" tanks.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 173: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 436

Room Name WC Soiled Linen / Trash Room

Net Area 120

Quantity 1

Adjacency Exam Rooms

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment Provide Industrial-grade solid shelving.

Arch Notes

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Provide 100% exhaust from space. No air recirculation allowed.

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Utility sink.

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 174: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 437

Room Name WC Medical Supply Storage

Net Area 120

Quantity 1

Adjacency Close to WC Staff Locker Area, WC Clean Linen, and WC Soiled Linen / Trash Room.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 4 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 175: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 438

Room Name WC Oxygen Storage Room

Net Area 80

Quantity 1

Adjacency WC Medical Supply Storage

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 4 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 176: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 439

Room Name WC Staff Locker Area

Net Area 100

Quantity 1

Adjacency WC Soiled Linen / Trash Room, WC Clean Linen, and Staff Toilets.

Floor Finish VCT

Wall Finish Sanitary Wainscot

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment Half Lockers for 24 people.Benches.

Arch Notes

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 177: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 440

Room Name WC Medical Waste

Net Area 24

Quantity 1

Adjacency Exam Rooms

Floor Finish Sheet Vinyl

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment Medical Waste containers provided by Medical Waste

Arch Notes

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Provide 100% exhaust from space. No air recirculation allowed.

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 178: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 441

Room Name Nourishment Center / Break Room

Net Area 400

Quantity 1

Adjacency WC Staff Offices

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework Plam Wall Base & Top

Equipment Kitchenette with full-size refrigerator and microwave.

Arch Notes Tables and seating for 12.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( x ) Cable TV ( x )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Provide receptacles on standby power for refrigerator and kitchenette.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes: Provide lighting on standby power.

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 179: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 442

Room Name Clinical Dietician

Net Area 120

Quantity 1

Adjacency WC Staff Offices

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 180: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 443

Room Name WC Social Worker

Net Area 120

Quantity 1

Adjacency WC Staff Offices

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 181: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 444

Room Name WC Staff Toilet

Net Area 70

Quantity 2

Adjacency WC Staff Offices

Floor Finish Ceramic Tile

Wall Finish Ceramic Tile Wet Wall

Base Ceramic

Ceiling Finish Painted GWB

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework

Equipment Provide complete stainless steel toilet accessories.

Arch Notes ADA accessible water closet and sink.1 Men assigned.1 Women assigned.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( x ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Privacy SetCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 182: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 445

Room Name Rehabilitation Services

Net Area 3000

Quantity 1

Adjacency Locate along public corridor.Adjacent to Wellness Center.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 4 ACT

Door Type Glass DBL

Wall Construction Metal Stud w/Impact Res. GWB

Casework Plam Wall Base & Top

Equipment 1 treadmill, 2-3 stationary bikes, 1 parallel bars and steps. Hot pack station, 2 tables with massage mats1 small Jacuzzi (limbs), 1 Aquasizer, Paraffin hot wax, and fluido-therapy equipment.

Arch Notes Sub-divide into 2 Rehab Clinics (PT and OT). Provide one accessible unisex toilet room in each clinic.Provide ADL Bathroom with shower.Include 200 sf locked storage.Provide seating for 6-8.Ceiling lift-track system ("Voyager" style).

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( x ) Shower ( x ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( x )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 183: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 446

Room Name Rehab Spa / Bathing

Net Area 230

Quantity 1

Adjacency Rehabilitation Services

Floor Finish Rubber

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework

Equipment Ceiling lift-track system ("voyager" style).Podiatric sink.Recumbent, fast-fill tub, usable from ceiling or hydraulic lift.

Arch Notes No-wall shower (floor drain and sanitary walls).Provide pull-down "Lalido" bars at toilet, and standard grab bars elsewhere as required.Provide exterior window and appropriate window treatment for natural light.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( x ) Shower ( x ) Soak Tub ( x ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( x ) Data ( ) Audio-Video ( ) Access Control Privacy SetCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Include emergency phone.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 184: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 447

Room Name Rehab Storage

Net Area 200

Quantity 1

Adjacency Rehabilitation Services and Evaluation / Treatment Room.

Floor Finish Sealed Concrete

Wall Finish Paint

Base None

Ceiling Finish No Ceiling

Door Type Wood SGL

Wall Construction CMU

Casework

Equipment

Arch Notes

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 185: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 448

Room Name Evaluation / Treatment Room

Net Area 200

Quantity 1

Adjacency Rehabilitation Services

Floor Finish Carpet 36 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework

Equipment Provide observation window into Rehabilitation Services.

Arch Notes Work table with lockable storage and 4 chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 186: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 449

Room Name Director of Rehabilitation Services

Net Area 120

Quantity 1

Adjacency Rehabilitation Services

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment Provide observation window into Rehab Activity Room

Arch Notes Standard desk and credenza with 2 visitor chairs.Used for private conversation.Provide acoustical treatment.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 187: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 450

Room Name Occupational Therapists

Net Area 160

Quantity 1

Adjacency Rehabilitation Services

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment Provide observation window into Rehabilitation Services.

Arch Notes Provide 2 workstations in same room.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 188: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 451

Room Name Physical Therapists

Net Area 160

Quantity 1

Adjacency Rehabilitation Services

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment Provide observation window into Rehabilitation Services.

Arch Notes Provide 2 workstations in same room.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

d

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 189: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 452

Room Name Nurse Educator

Net Area 120

Quantity 1

Adjacency Education Classroom

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 190: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 453

Room Name Education Classroom

Net Area 700

Quantity 1

Adjacency Locate along public corridor.Adjacent to Assisted Living offices

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL w/Side Lite

Wall Construction Metal Stud w/Impact Res. GWB

Casework

Equipment Include filing cabinets.Provide motorized projection screen, whiteboard, and projector.

Arch Notes Work tables and chairs for 25 people and 1 instructorProvide lockable storage units.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( x ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( x )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 191: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 454

Room Name Classroom Storage

Net Area 100

Quantity 1

Adjacency Education Classroom

Floor Finish Sealed Concrete

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework

Equipment Provide Industrial-grade solid shelving.

Arch Notes

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 192: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 455

Room Name Reference Library

Net Area 200

Quantity 1

Adjacency Locate along public corridor.Adjacent to Education Classroom.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL w/Side Lite

Wall Construction Metal Stud w/Impact Res. GWB

Casework

Equipment

Arch Notes Library furniture and shelving.Include seating for 6-8 people.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 193: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 456

Room Name Healthcare Administrator

Net Area 200

Quantity 1

Adjacency Administrative Assistant and Director of Nursing.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 194: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 457

Room Name Administrative Assistant

Net Area 100

Quantity 1

Adjacency Healthcare Administrator, Director of Nursing, Conference Room, and Work / Copy Room

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment Printers, fax machines, copiers, filing cabinets.

Arch Notes Locate in same room as Director of Nursing's Administrative Assistant.Secretarial workstation.Secured room.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 195: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 458

Room Name Director of Nursing

Net Area 120

Quantity 1

Adjacency Administrative Assistant and Healthcare Administrator.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 196: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 459

Room Name Administrative Assistant

Net Area 100

Quantity 1

Adjacency Director of Nursing, Healthcare Administrator, Conference Room, and Work / Copy Room.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 4 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment Printers, fax machines, copiers, filing cabinets.

Arch Notes Locate in same room as Director of Nursing's Administrative Assistant.Secretarial workstation.Secured room.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 197: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 460

Room Name MDS Coordinator

Net Area 120

Quantity 1

Adjacency Healthcare Administrator, Director of Nursing, Performance Improvement Office, Conference Room, and Inventory Supply Specialist.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) -

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 198: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 461

Room Name Performance Improvement Office

Net Area 200

Quantity 1

Adjacency Healthcare Administrator, Director of Nursing, MDS Coordinator, Conference Room, and Inventory Supply Specialist.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.Provide space for additional filing storage.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 199: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 462

Room Name Conference Room

Net Area 240

Quantity 1

Adjacency Locate along public corridor.Adjacent to Administrative Assistants, Healthcare Administrator, Director of Nursing, and Work / Copy Room.

Floor Finish Carpet 36 oz

Wall Finish Paint

Base Wood

Ceiling Finish ACT w/GWB Accents

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment Motorized projection screen (recessed automatic), and wall-mounted whiteboard (9' x 8').Provide emergency cabinet.

Arch Notes Large conference table and seating for 12.Space for social workers and group sessions.Provide acoustical treatment.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( x ) Cable TV ( x )

Tele Data Special Requirements

Provide wireless conference phone.Include additional voice and data capacity.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Dimming

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 200: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 463

Room Name Central Medical Supply

Net Area 200

Quantity 1

Adjacency Locate along public corridor.Adjacent to Inventory Supply Specialist.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework

Equipment Provide Industrial-grade solid shelving.

Arch Notes

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 201: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 464

Room Name Inventory Supply Specialist

Net Area 120

Quantity 1

Adjacency Central Medical Supply

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment Copier machines, fax machines, and filing cabinets.

Arch Notes Secretarial workstation with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 202: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 465

Room Name Work / Copy Room

Net Area 160

Quantity 1

Adjacency Administrative Assistants and Conference Room.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework Plam Wall Base & Top

Equipment Copiers, fax machines, and printers.

Arch Notes Storage cabinets and work counters.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( x ) Cable TV ( )

Tele Data Special Requirements

Provide additional telephone and data capacity.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 203: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 466

Room Name Independent Living 2 Units

Net Area 450

Quantity 24

Adjacency

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish Painted GWB

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework Plam Wall Base & Top

Equipment Same as Independent Living 1 Units.

Arch Notes Same as Independent Living 1 Units.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( x ) Shower ( x ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( x )

Tele Data Special Requirements

Same as Independent Living 1 Units.

Sprinkler Quick Response Heads

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Same as Independent Living 1 Units.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes: Same as Independent Living 1 Units.

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 204: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 467

Room Name IL2 Home Base

Net Area 270

Quantity 2

Adjacency IL2 Main Entrance

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type

Wall Construction Metal Stud w/Impact Res. GWB

Casework Plam Wall Base & Top

Equipment Same as AL Home Base.

Arch Notes 1 unit serves 12 residents.Same as AL Home Base.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Same as AL Home Base.

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control NoneCCTV ( ) Cable TV ( x )

Tele Data Special Requirements

Same as AL Home Base.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Same as AL Home Base.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 205: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 468

Room Name IL2 Work Space

Net Area 45

Quantity 4

Adjacency Resident Corridor

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework

Equipment Same as MS Work Space.

Arch Notes Same as MS Work Space.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control NoneCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 206: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 469

Room Name IL2 Activity Room

Net Area 1000

Quantity 1

Adjacency IL2 Home Base and Staff Work Area

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish ACT w/GWB Accents

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework Plam Wall Base & Top

Equipment Same as MS Activity Room.

Arch Notes Same as MS Activity Room.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Same as MS Activity Room.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Same as MS Activity Room.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 207: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 470

Room Name IL2 Public Toilet Room

Net Area 70

Quantity 2

Adjacency

Floor Finish Ceramic Tile

Wall Finish Ceramic Tile 1/2 Ht.

Base Ceramic

Ceiling Finish Painted GWB

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework Plam Base & Top

Equipment Same as IL1 Public Toilet Rooms (M & W).

Arch Notes Same as IL1 Public Toilet Rooms (M & W).

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( x ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Privacy SetCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 208: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 471

Room Name IL2 Medical Waste Storage

Net Area 24

Quantity 2

Adjacency IL2 Laundry Room

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework

Equipment Same as AL Medical Waste Storage.

Arch Notes Same as AL Medical Waste Storage.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Provide 100% exhaust from space. No recirculation allowed.

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 209: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 472

Room Name IL2 Laundry Room

Net Area 100

Quantity 2

Adjacency Elevators

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment Same as IL1 Laundry Room.

Arch Notes Same as IL1 Laundry Room.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Same as IL1 Laundry Room.

Voice ( Data ( ) Audio-Video ( ) Access Control NoneCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Same as IL1 Laundry Room.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Same as IL1 Laundry Room.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 210: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 473

Room Name IL2 Staff Toilet

Net Area 70

Quantity 2

Adjacency Staff Area and IL2 Home Base

Floor Finish Seamless Vinyl

Wall Finish Paint

Base Vinyl

Ceiling Finish Painted GWB

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework Plam Base & Top

Equipment Same as AL Staff Toilet.

Arch Notes Same as AL Staff Toilet.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( x ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Privacy SetCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 211: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 474

Room Name IL2 Nurse Practitioner

Net Area 120

Quantity 1

Adjacency IL2 Social Worker and IL2 Work Space.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment Same as MS Nurse Practitioner.

Arch Notes Same as MS Nurse Practitioner.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 212: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 475

Room Name IL2 Social Worker

Net Area 120

Quantity 1

Adjacency IL2 Nurse Practitioner and IL2 Work Space.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment Same as AL Social Worker.

Arch Notes Same as AL Social Worker.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 213: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 476

Room Name Assisted Living Units (AL)

Net Area 450

Quantity 60

Adjacency Refer to Assisted Living Unit Adjacency Diagram.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish Painted GWB

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework Plam Wall Base & Top

Equipment Full kitchenette with sink and area for "mini" refrigerator and microwave oven.Include "lock boxes" for valuables (6" x 12" - Type TBD).

Arch Notes Includes full accessible bath with sink, toilet and shower.Provide rubber floor and "sanitary" walls in bathroom for wash down.Provide pull-down bars at toilet, and standard grab bars elsewhere as required.Provide connecting door for 10% of units.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( x ) Shower ( x ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Provide fully-waterproofed floor in bathroom.Provide separate floor drains in shower and bathroom floor.

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( x )

Tele Data Special Requirements

Provide 2 telephone outlets (on opposite walls) and one data connection with 2 data linesProvide one emergency device in bathroom and 2 devices in living area connected to the Resident Monitoring System (including Wellness Center Check-In Button).

Sprinkler Quick Response Heads

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Provide one duplex outlet in each room on standby power circuit.Provide circuit for personal battery powered vehicle charging.Nurse Call System shall be on standby power.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes: Provide one permanently installed lighting fixture in the living unit and one permanently installed lighting fixture in the bathroom on standby power.Provide indirect lighting in living area.

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 214: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 477

Room Name AL Home Base

Net Area 270

Quantity 2

Adjacency AL Main Entrance and Club Room

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type

Wall Construction Metal Stud w/Impact Res. GWB

Casework Plam Wall Base & Top

Equipment Include copy machine, refrigerator, and Nurse Call System base unit."Home Free" system and other equipment as required by AFRH.

Arch Notes 1 unit serves 30 residents.Open nurses' station with lockable storage.Includes patient records storage in lateral files.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Provide handwashing sink.

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control NoneCCTV ( ) Cable TV ( x )

Tele Data Special Requirements

Nurse call.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Provide multiple outlets for monitoring equipment.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 215: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 478

Room Name AL Club Room

Net Area 1080

Quantity 2

Adjacency AL Home Base

Floor Finish Carpet 36 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish ACT w/GWB Accents

Door Type Glass DBL

Wall Construction Metal Stud w/Impact Res. GWB

Casework

Equipment Include recessed emergency medical cabinet (wired to security).

Arch Notes 1 Club Room per 30 residents.Provide lounge seating for 30 - 40 people.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control NoneCCTV ( ) Cable TV ( x )

Tele Data Special Requirements

Include Nurse Call device, emergency phone and AED (electronically monitored by security).

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 216: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 479

Room Name AL Activity Room

Net Area 340

Quantity 1

Adjacency AL Club Room, AL Nourishment Center, and AL Home Base.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish ACT w/GWB Accents

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework Plam Wall Base & Top

Equipment Kitchenette with full-size refrigerator.

Arch Notes 1 Activity Room per 60 residents.Movable wall.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( x ) Cable TV ( x )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 217: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 480

Room Name AL Nourishment Center

Net Area 100

Quantity 1

Adjacency Locate along internal corridor near AL Home Base.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework Plam Wall Base & Top

Equipment Kitchenette with full-size refrigerator and microwave.

Arch Notes 1 Nourishment Center for 30 residents.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( ) Audio-Video ( ) Access Control NoneCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 218: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 481

Room Name AL Spa / Bathing Room

Net Area 230

Quantity 2

Adjacency AL Home Base and Resident Corridor.

Floor Finish Rubber

Wall Finish Ceramic Tile 1/2 Ht.

Base Ceramic

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework

Equipment Ceiling lift-track system ("voyager" style).Podiatric sink.Recumbent, fast-fill tub, usable from ceiling or hydraulic lift.

Arch Notes 1 Spa / Bathing Rm per 30 residents.No-wall shower (floor drain and sanitary walls).Provide pull-down "Lalido" bars at toilet, and standard grab bars elsewhere as required.Provide exterior window and appropriate window treatment for natural light.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( x ) Shower ( x ) Soak Tub ( x ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( x ) Data ( ) Audio-Video ( ) Access Control Privacy SetCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Include Nurse Call device and emergency phone.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 219: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 482

Room Name AL Public Toilet Room

Net Area 70

Quantity 2

Adjacency AL Home Base and Resident Corridor.

Floor Finish Ceramic Tile

Wall Finish Ceramic Tile 1/2 Ht.

Base Ceramic

Ceiling Finish Painted GWB

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework Plam Base & Top

Equipment Provide complete stainless steel toilet accessories.

Arch Notes 1 Public Toilet Room per 30 residents.Provide accessible water closet and sink.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( x ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Privacy SetCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Include Nurse Call device and emergency phone.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 220: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 483

Room Name AL Clean Linen

Net Area 120

Quantity 2

Adjacency AL Home Base.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework

Equipment Provide Industrial-grade solid shelving.

Arch Notes 1 Clean Supply Room per 30 residents.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 221: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 484

Room Name AL Soiled Linen / Trash Room

Net Area 120

Quantity 2

Adjacency Near AL Living Units

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework

Equipment

Arch Notes 1 Soiled Linen / Trash Room per 15 residents.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Provide 100% exhaust from space. No air recirculation.

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 222: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 485

Room Name AL Medical Storage

Net Area 150

Quantity 1

Adjacency AL Medication Room and AL Medical Waste Storage.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 223: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 486

Room Name AL Medical Supply Storage

Net Area 80

Quantity 2

Adjacency AL Home Base

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework

Equipment Provide Industrial-grade solid shelving.

Arch Notes

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 224: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 487

Room Name AL Medical Waste Storage

Net Area 24

Quantity 2

Adjacency AL Home Base.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework

Equipment Medical Waste containers provided by Housekeeping Contractor.

Arch Notes 1 Medical Waste Storage Room per 30 residents.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Provide 100% exhaust from space. No air recirculation.

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 225: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 488

Room Name AL Medication Room

Net Area 120

Quantity 2

Adjacency AL Home Base

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework Plam Wall Base & Top

Equipment Full-size refrigerator.

Arch Notes 1 Medication Room per 30 residents.Includes handwashing station and lockable storage units.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Refrigerator and minimal lighting only.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 226: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 489

Room Name AL Laundry Room

Net Area 100

Quantity 2

Adjacency AL Home Base

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework Plam Base & Top

Equipment Commercial-grade Washer / Dryer and deep stackable front load. ADA-accessible sink.Provide Industrial-grade solid shelving.Warpool system for drying and "steaming" equipment

Arch Notes 1 Laundry Room per 30 residents.Include table for folding laundry, clothes rod, and 2 chairs.Provide special ventilation and acoustical treatment.Water temperature booster in laundry rooms for one of washer --controlled by staff.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Provide utility sink.Provide special floor drain to accommodate washer overflow.

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 227: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 490

Room Name AL Staff Break Area

Net Area 150

Quantity 2

Adjacency AL Home Base

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework Plam Wall Base & Top

Equipment Half-height lockers for 16 employees.Kitchenette with full-size refrigerator.

Arch Notes 1 Staff Break Area per 30 residents.Tables and chairs for 6.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 228: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 491

Room Name AL Staff Toilet

Net Area 70

Quantity 2

Adjacency AL Staff Break Area

Floor Finish Seamless Vinyl

Wall Finish Paint

Base Vinyl

Ceiling Finish Painted GWB

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework Plam Base & Top

Equipment Provide complete stainless steel toilet accessories.

Arch Notes ADA accessible water closet and sink.1 Men assigned.1 Women assigned.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( x ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Privacy SetCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc): 10

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 229: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 492

Room Name AL Clinical Supervisor

Net Area 200

Quantity 1

Adjacency AL Medical Provider, AL Medical Records Technician, AL Recreational Therapist, AL Dietician, and AL Social Worker.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 230: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 493

Room Name AL Medical Provider

Net Area 200

Quantity 1

Adjacency AL Clinical Supervisor, AL MedicalRecords Technician, AL Recreational Therapist, and AL Dietician.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework Ptd Metal Base w/Solid Surface Top

Equipment

Arch Notes Seamless floor non-glare sheet, pre-finished for one step cleaning process.Conference table with 4 chairs.Serves as Exam Room.Exam Table and workstation.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Include handwashing station.

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 231: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 494

Room Name AL Medical Records Technician

Net Area 120

Quantity 1

Adjacency Locate along public corridor.Adjacent to Assisted Living Unit Entrance.Close to AL Home Base (2)

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL w/Side Lite

Wall Construction Metal Stud w/GWB

Casework

Equipment Medical charts carousel (60 residents).

Arch Notes Secretarial workstation.Functions as reception area for Assisted Living Offices.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 232: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 495

Room Name AL Recreational Therapist

Net Area 120

Quantity 1

Adjacency Director of Health Services

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Nurse call.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 233: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 496

Room Name AL Dietician

Net Area 120

Quantity 1

Adjacency AL Recreational Therapist

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 234: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 497

Room Name AL Social Worker

Net Area 120

Quantity 1

Adjacency AL Nurse Manager

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 235: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 498

Room Name Memory Support Units (MS)

Net Area 350

Quantity 24

Adjacency MS Home Base and Staff Work Areas.

Floor Finish Carpet 36 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish Painted GWB

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework

Equipment Include "lock boxes" for valuables (6" x 12" - Type TBD).Provide Nurse Call device in living area and CCTV in hallways.

Arch Notes Includes full accessible bath with sink, toilet and shower.Provide rubber floor and "sanitary" walls in bathroom for wash down.Provide pull-down bars at toilet, and standard grab bars elsewhere as required.Provide connecting door for 10% of units.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( x ) Shower ( x ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Provide fully-waterproofed floor in bathroom.Provide separate floor drains in shower and bathroom floor.

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( x )

Tele Data Special Requirements

Provide 2 telephone outlets (on opposite walls) and one data connection with 2 data linesProvide one emergency device in bathroom and 2 devices in living area connected to the Resident Monitoring System (including Wellness Center Check-In Button).

Sprinkler Quick Response Heads

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Provide one duplex outlet in each room on standby power circuit.Provide circuit for personal battery powered vehicle charging.Nurse Call System shall be on standby power.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes: Provide one permanently installed lighting fixture in the living unit and one permanently installed lighting fixture in the bathroom on standby power.Provide indirect lighting in living area.

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 236: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 499

Room Name MS Day Club

Net Area 5600

Quantity 1

Adjacency Locate on common corridor.Adjacent to MS Dining Room and Country Kitchen.Shared with LTC.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL w/Side Lite

Wall Construction Metal Stud w/Impact Res. GWB

Casework

Equipment Piano, TV, and games.Provide storage closets for games and supplies.Include recessed emergency medical cabinet (wired to security).

Arch Notes Provide walkable space for MS residents.Include controlled Outside Area on same floor.Tables and chairs for 35 - 40 people seating in groups.Provide unisex toilet room and storage cabinets.Provide "cubby" space for individual storage (24).

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( x ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( x )

Tele Data Special Requirements

Include Nurse Call device, emergency phone and AED (electronically monitored by security).

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Electric locks to be conduited with emergency power.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 237: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 500

Room Name MS Secure Exterior Patio

Net Area 3500

Quantity 1

Adjacency MS Day Club

Floor Finish Stone

Wall Finish Paint

Base Stone

Ceiling Finish No Ceiling

Door Type

Wall Construction

Casework

Equipment Include enclosing fence and motion detection securityfeatures.Gazebo and / or trellis.

Arch Notes Provide level surfaces for group and individual activity with shade.Include edge details that reduce the potential to placea chair or climb the fence.May be used as an emergency exit into a safe area orefuge.Expect pet visitation to this area.

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 82 Deg (F)

% R Humidity (Winter) -

% R Humidity (Summer) 60%

Special HVAC Requirements

No HVAC service required for this space.

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Include Motion Detector.Include emergency phone and Home Free system.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching:

Lighting Notes:

May 21, 2007AFRH Gulport RFP Base Bid

Page 238: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 501

Room Name MS Home Base

Net Area 270

Quantity 2

Adjacency MS Dining Room and Activity Room.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL w/Side Lite

Wall Construction Metal Stud w/GWB

Casework Plam Wall Base & Top

Equipment Include copy machine, refrigerator, and Nurse Call System base unit."Home Free" system and other equipment as required by AFRH.

Arch Notes 1 Home Base per 12 residents.Locate to maintain visual connection to all resident units.Included patient records storage in lateral files.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( x )

Tele Data Special Requirements

Nurse call.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Provide multiple outlets for monitoring equipment.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 239: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 502

Room Name MS Work Space

Net Area 45

Quantity 4

Adjacency Resident Corridor

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type

Wall Construction Metal Stud w/Impact Res. GWB

Casework Plam Base & Top

Equipment

Arch Notes 1 Work Space per 6 residents.Locate on resident corridor (no door).Include patient record storage (stand alone and movable).Lockable storage units.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control NoneCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 240: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 503

Room Name MS Dining Room

Net Area 1080

Quantity 1

Adjacency MS Home Base and Activity Room

Floor Finish VCT

Wall Finish Wainscott"

Base Vinyl

Ceiling Finish ACT w/GWB Accents

Door Type Wood DBL

Wall Construction Metal Stud w/Impact Res. GWB

Casework

Equipment Movable partition between Dining and Activity.

Arch Notes 1 Dining Room per all MS residents.Estimated seating for 32 (28 SF / person). NO ROUND TABLES.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Include handwashing station.

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( x )

Tele Data Special Requirements

Nurse call.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 241: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 504

Room Name MS Servery

Net Area 300

Quantity 1

Adjacency MS Dining Room

Floor Finish Sheet Vinyl

Wall Finish Paint

Base Vinyl

Ceiling Finish Painted GWB

Door Type Wood SGL

Wall Construction CMU w/GWB

Casework Plam Wall Base & Top

Equipment Stainless steel service line equipment.

Arch Notes "Functionally accessible for older people."ADA compliant.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control NoneCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Provide receptacles on standby power to allow for fully functional kitchen service.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes: Provide lighting on standby power to allow for fully functional kitchen service.

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 242: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 505

Room Name MS Activity Room

Net Area 1000

Quantity 1

Adjacency MS Home Base and Staff Work Area

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish ACT w/GWB Accents

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework Plam Wall Base & Top

Equipment Kitchenette with full-size refrigerator.

Arch Notes 1 Activity Room per 24 residents.Movable wall.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( x )

Tele Data Special Requirements

Nurse call.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Refrigerator only.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes: Minimal lighting for access to refrigerator.

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 243: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 506

Room Name MS Country Kitchen

Net Area 200

Quantity 1

Adjacency MS Activity Room

Floor Finish Sheet Vinyl

Wall Finish Paint

Base Vinyl

Ceiling Finish Painted GWB

Door Type Wood Pocket

Wall Construction CMU w/GWB

Casework Plam Wall Base & Top

Equipment Kitchen equipment including sink, stove, and full-size refrigerator.

Arch Notes Open to MS Activity Room.Pass through countertop with 4 stools.

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Provide kitchen make-up air and exhaust system in accordance with Code.

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( ) Audio-Video ( ) Access Control NoneCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Refrigerator on emergency power.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 244: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 507

Room Name MS Activity Alcove (one person)

Net Area 180

Quantity 2

Adjacency MS Home Base and Staff Work Area.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes 1 Activity Alcove per 12 residents.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control NoneCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Nurse call.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 245: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 508

Room Name MS Spa / Bathing Room

Net Area 230

Quantity 2

Adjacency MS Home Base and Resident Corridor.

Floor Finish Rubber

Wall Finish Ceramic Tile 1/2 Ht.

Base Ceramic

Ceiling Finish 2 x 2 ACT

Door Type Wood DBL

Wall Construction Metal Stud w/GWB

Casework

Equipment Ceiling lift-track system ("voyager" style).Podiatric sink.Recumbent, fast-fill tub, usable from ceiling or hydraulic lift.

Arch Notes 1 Spa / Bathing Rm per 12 residents.No-wall shower (floor drain and sanitary walls).Provide pull-down "Lalido" bars at toilet, and standard grab bars elsewhere as required.Provide exterior window and appropriate window treatment for natural light.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( x ) Shower ( x ) Soak Tub ( x ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Include Nurse Call device and emergency phone.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 246: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 509

Room Name MS Public Toilet Room

Net Area 70

Quantity 2

Adjacency MS Home Base and Resident Corridor.

Floor Finish Ceramic Tile

Wall Finish Ceramic Tile 1/2 Ht.

Base Ceramic

Ceiling Finish Painted GWB

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework Plam Base & Top

Equipment Provide complete stainless steel toilet accessories.

Arch Notes 1 Public Toilet Room per 12 residents.Provide accessible water closet and sink.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( x ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Privacy SetCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Include Nurse Call device and emergency phone.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 247: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 510

Room Name MS Clean Linen

Net Area 120

Quantity 2

Adjacency MS Home Base.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment Provide Industrial-grade solid shelving.

Arch Notes 1 Clean Linen Room per 12 residents.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 248: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 511

Room Name MS Soiled Linen / Trash Room

Net Area 60

Quantity 4

Adjacency MS Home Base

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes 1 Soiled Room per 6 residents.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Provide 100% exhaust from space. No air recirculation.

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 249: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 512

Room Name MS Medical Supply Storage

Net Area 80

Quantity 1

Adjacency MS Home Base

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework

Equipment Provide industrial-grade solid shelving.

Arch Notes

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 250: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 513

Room Name MS Medical Waste Storage

Net Area 24

Quantity 2

Adjacency MS Home Base.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework

Equipment Medical Waste containers provided by Housekeeping Contractor.

Arch Notes 1 Medical Waste Storage Room per 12 residents.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Provide 100% exhaust from space. No air recirculation allowed.

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc): 10

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 251: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 514

Room Name MS Medication Room

Net Area 110

Quantity 2

Adjacency MS Home Base.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework Plam Wall Base & Top

Equipment Full-size refrigerator.

Arch Notes 1 Medication Room per 12 residents.Includes handwashing station and lockable storage units.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Refrigerator for medications.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes: Minimal lighting for emergency access to refrigerator.

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 252: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 515

Room Name MS Laundry Room

Net Area 100

Quantity 2

Adjacency MS Home Base.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework Plam Wall Base & Top

Equipment Commercial-grade Washer / Dryer and deep stackable front load. ADA-accessible sink.Provide Industrial-grade solid shelving.Warpool system for drying and "steaming" equipment

Arch Notes 1 Laundry Room per 12 residents.Include table for folding laundry, clothes rod, and 2 chairs.Provide special ventilation and acoustical treatment.Water temperature booster in laundry rooms for one of washer --controlled by staff.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Provide utility sink.Provide special floor drain to accommodate washer overflow.

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 253: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 516

Room Name MS Staff Break Area

Net Area 150

Quantity 2

Adjacency MS Home Base

Floor Finish VCT

Wall Finish Sanitary Wainscot

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment Half-height lockers for 16 employees.Kitchenette with full-size refrigerator.

Arch Notes 1 Staff Break Area per 30 residents.Tables and chairs for 6.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 254: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 517

Room Name MS Staff Toilet

Net Area 70

Quantity 2

Adjacency MS Home Base and MS Staff Break Area

Floor Finish Ceramic Tile

Wall Finish Ceramic Tile Wet Wall

Base Ceramic

Ceiling Finish Painted GWB

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework Plam Base & Top

Equipment Provide complete stainless steel toilet accessories

Arch Notes ADA accessible water closet and sink.1 Men assigned.1 Women assigned.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( x ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Privacy SetCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 255: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 518

Room Name MS Clinical Supervisor

Net Area 120

Quantity 1

Adjacency MS Staff Area

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 256: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 519

Room Name MS Medical Records Technician

Net Area 80

Quantity 1

Adjacency Locate along public corridor.Adjacent to Memory Support Unit Entrance, and MS Staff Area.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL w/Side Lite

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Secretarial workstation.Functions as reception area for Memory Support Offices.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 257: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 520

Room Name MS Nurse Practitioner

Net Area 120

Quantity 1

Adjacency MS Staff Area

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 258: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 521

Room Name MS Dietician

Net Area 120

Quantity 1

Adjacency MS Staff Area

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 259: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 522

Room Name MS Social Worker

Net Area 120

Quantity 1

Adjacency MS Staff Area

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 260: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 601

Room Name Security Gate House

Net Area 150

Quantity 1

Adjacency Main Vehicular Site Entrance

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Metal SGL

Wall Construction CMU w/GWB

Casework Security Desk

Equipment Gates and retractable bollards at entrance roadways.Security equipment as required.

Arch Notes Includes accessible toilet room with toilet and sink.Provide glazing to control all security barriers.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( x ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( x ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 261: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 602

Room Name Exterior Recreational Terrace

Net Area 3000

Quantity 1

Adjacency Dining Room

Floor Finish Stone

Wall Finish Paint

Base Stone

Ceiling Finish No Ceiling

Door Type

Wall Construction

Casework

Equipment Grilles, serving line equipment, and work tables for outside events.

Arch Notes Moveable tables, chairs, benches, etc. to accommodate 100 to 350 people.

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 82 Deg (F)

% R Humidity (Winter) -

% R Humidity (Summer) 60%

Special HVAC Requirements

No HVAC service required for this space.

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Provide floor drains as required.

Voice ( x ) Data ( ) Audio-Video ( ) Access Control NoneCCTV ( x ) Cable TV ( )

Tele Data Special Requirements

Provide emergency phone.Provide capacity for portable outdoor telephone.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.Provide power for portable outdoor electrical appliances and equipment.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Base Bid

Page 262: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007

General Services Administration Public Buildings Service Southeast Sunbelt Region Real Estate Design and Construction

UNCLASSIFIED

OPTION 1

Page 263: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 226

Room Name Main Trash Rooms

Net Area 300

Quantity 1

Adjacency Trash Chutes (from above).Easy access to Loading Dock.

Floor Finish Sealed Concrete

Wall Finish Paint

Base None

Ceiling Finish No Ceiling

Door Type Metal DBL

Wall Construction CMU

Casework

Equipment Trash compactor and trash chute with fire-rated doorsat each level.Include smoke detectors in chute.

Arch Notes 1 Trash Room per 150 Units.The DBC shall describe how trash removal is addressed.May be located at First Floor or Wash-Out Level.

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Self-cleaning trash chute will require water supply and drain.

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Quick Response Heads

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

May 21, 2007AFRH Gulport RFP Option 1

Page 264: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 227

Room Name Trash Room (Includes all Living Units)

Net Area 50

Quantity 9

Adjacency Elevators, Janitor Closet, and Laundry Room.

Floor Finish Sealed Concrete

Wall Finish Paint

Base None

Ceiling Finish No Ceiling

Door Type Metal SGL

Wall Construction CMU

Casework

Equipment Self-cleaning trash chute with fire-rated doors.Recycling bins provided by Housekeeping Contractor.

Arch Notes 1 trash room per 24 residents ( Independent Living).1 trash room per 30 residents (Assisted Living).1 trash room per 12 residents (Memory Support and Long Term Care).

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control NoneCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 1

Page 265: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 322

Room Name Janitor's Closet (On Residential Units Levels)

Net Area 30

Quantity 9

Adjacency Trash Room.

Floor Finish

Wall Finish

Base

Ceiling Finish

Door Type

Wall Construction

Casework

Equipment Mop sink and rack.

Arch Notes Provide at least one Janitor's Closet per floor.

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 1

Page 266: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 379

Room Name IL1Independent Living Units

Net Area 450

Quantity 170

Adjacency See Adjacency Diagram for Typical Independent Living Level.

Floor Finish Anti Microbial Carpet

Wall Finish Paint

Base Vinyl

Ceiling Finish Painted GWB

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework Wood Wall Base & Solid Surface Top

Equipment Full kitchenette with sink and area for "mini" refrigerator and microwave oven.Include "lock boxes" for valuables (6" x 12" - Type TBD).

Arch Notes Includes full accessible bath with sink, toilet and shower.Provide rubber floor and "sanitary" walls in bathroom for wash down.Provide pull-down bars at toilet, and standard grab bars elsewhere as required.Provide connecting door for 10% of units.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( x ) Shower ( x ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Provide fully-waterproofed floor in bathroom.Provide separate floor drains in shower and bathroom floor.

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access W/KeyCCTV ( ) Cable TV ( x )

Tele Data Special Requirements

Provide 2 telephone outlets (on opposite walls) and 1 data connection with 2 data lines.Provide 1 emergency device in bathroom and 2 devices in living area connected to the Resident Monitoring System (including Wellness Center Check-In Button).

Sprinkler Quick Response Heads

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Provide one duplex outlet in each room on standby power circuit.Provide circuit for personal battery powered vehicle charging.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes: Provide indirect lighting in living area.Provide one permanently installed lighting fixture in the living unit and one permanently installed lighting fixture in the bathroom on standby power.

Per IESNA

May 21, 2007AFRH Gulport RFP Option 1

Page 267: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 380

Room Name IL1 Day Room / Lounge

Net Area 250

Quantity 7

Adjacency Elevator Lobby and Resident Corridor.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish Painted GWB

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework Plam Wall Base & Top

Equipment

Arch Notes 1 unit serves 24 residents.Provide TV, couches and chairs, and 2 card tables with 4 chairs each.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( x )

Tele Data Special Requirements

Include emergency phone and AED.

Sprinkler Dry Pipe System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 1

Page 268: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 381

Room Name IL1 Laundry Room

Net Area 100

Quantity 7

Adjacency Elevators, Janitor Closet, and Trash Room.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type

Wall Construction Metal Stud w/GWB

Casework Plam Wall Base & Top

Equipment Commercial-grade Washer / Dryer and deep stockable front load. ADA-accessible sink.Provide Industrial-grade solid shelving.Warpool system for drying and "steaming" equipment

Arch Notes 1 Laundry Room per 24 residents.Include table for folding laundry, clothes rod, and 2 chairs.Provide special ventilation and acoustical treatment.Water temperature booster in laundry rooms for one of washer --controlled by staff.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Provide utility sink.Provide special oversized floor drain with gooseneck faucet to accommodate washer overflow.

Voice ( Data ( ) Audio-Video ( ) Access Control NoneCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 1

Page 269: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 382

Room Name IL1 Public Toilet Rooms (M & W)

Net Area 70

Quantity 14

Adjacency Day Room / Lounge and Independent Living Units.

Floor Finish Ceramic Tile

Wall Finish Ceramic Tile 1/2 Ht.

Base Ceramic

Ceiling Finish Painted GWB

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework Plam Base & Top

Equipment Provide complete stainless steel toilet accessories.

Arch Notes Fully ADA accessible water closet and sink.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( x ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Privacy SetCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 1

Page 270: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 523

Room Name Long-Term Care Units

Net Area 350

Quantity 24

Adjacency LTC Home Base and Staff Work Areas

Floor Finish Carpet 36 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish Painted GWB

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment Same as Memory Support Unit.Not Kitchenette.

Arch Notes Provide at least one Bariatric room with larger bed, ceiling lift track, and larger entry and bathroom doors.Provide connecting door between units for 10% of rooms.Ceiling structure in unit shall support ceiling lifts ("Voyage" style).

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( x ) Shower ( x ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Medical gases are not required in the Long Term Units.Provide fully-waterproofed floor in bathroom.Provide separate floor drains in shower and bathroom floor.

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( x )

Tele Data Special Requirements

Provide 2 telephone outlets (on opposite walls) and one data connection with 2 data linesProvide one emergency device in bathroom and 2 devices in living area connected to the Resident Monitoring System (including Wellness Center Check-In Button).

Sprinkler Quick Response Heads

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Provide one duplex outlet in each room on standby power circuit.Provide circuit for personal battery powered vehicle charging.Nurse Call System shall be on standby power.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes: Provide one permanently installed lighting fixture in the living unit and one permanently installed lighting fixture in the bathroom on standby power.Provide indirect lighting in living area.

Per IESNA

May 21, 2007AFRH Gulport RFP Option 1

Page 271: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 524

Room Name LTC Secure Exterior Patio

Net Area 3500

Quantity 1

Adjacency LTC Home Base and LTC Day / Visitor Room.

Floor Finish Stone

Wall Finish Paint

Base Stone

Ceiling Finish No Ceiling

Door Type

Wall Construction

Casework

Equipment Include enclosing fence and motion detection securityfeatures.Gazebo and / or trellis.

Arch Notes Provide level surfaces for group and individual activity with shade.Include edge details that reduce the potential to placea chair or climb the fence.May be used as an emergency exit into a safe area orefugeExpect pet visitation to this area.

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 82 Deg (F)

% R Humidity (Winter) -

% R Humidity (Summer) 60%

Special HVAC Requirements

No HVAC service required for this space.

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Include motion detector.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 1

Page 272: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 525

Room Name LTC Home Base

Net Area 270

Quantity 2

Adjacency MS Dining Room

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL w/Side Lite

Wall Construction Metal Stud w/GWB

Casework Plam Wall Base & Top

Equipment Include copy machine, refrigerator, and Nurse Call System base unit."Home Free" system and other equipment as required by AFRH.

Arch Notes Locate to maintain visual connection to all resident units.1 Home Base per 12 residents.Included patient records storage in lateral files.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( x )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Provide multiple outlets for monitoring equipment.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

PER IESNA

May 21, 2007AFRH Gulport RFP Option 1

Page 273: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 526

Room Name LTC Work Space

Net Area 45

Quantity 4

Adjacency Resident corridor and Long Term Care Units

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type

Wall Construction Metal Stud w/Impact Res. GWB

Casework

Equipment

Arch Notes 1 Work Space per 6 residents.Locate on resident corridor (no door).Include patient record storage (stand alone and movable).

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Key OnlyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 1

Page 274: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 527

Room Name LTC Dining Room

Net Area 1080

Quantity 1

Adjacency LTC Servery

Floor Finish VCT

Wall Finish Wainscott"

Base Vinyl

Ceiling Finish ACT w/GWB Accents

Door Type Glass DBL

Wall Construction Metal Stud w/Impact Res. GWB

Casework

Equipment

Arch Notes 1 Dining Room per all LTC residents.Estimated seating for 30-35 (28 SF / person). NO ROUND TABLES.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Include handwashing station.

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 1

Page 275: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 528

Room Name LTC Servery

Net Area 300

Quantity 1

Adjacency LTC Dining Room

Floor Finish Sheet Vinyl

Wall Finish Paint

Base Vinyl

Ceiling Finish Painted GWB

Door Type Wood SGL

Wall Construction CMU w/GWB

Casework Plam Wall Base & Top

Equipment Stainless steel service line equipment.

Arch Notes "Functionally accessible for older people."ADA compliant.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control NoneCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Provide receptacles on standby power to allow for fully functional kitchen service.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 1

Page 276: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 529

Room Name LTC Activity Room

Net Area 1000

Quantity 1

Adjacency LTC Country Kithcen, LTC Day / Visitor Room, LTC Nourishment Center, and LTC Home Base.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish ACT w/GWB Accents

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment Kitchenette with full-size refrigerator.

Arch Notes 1 Activity Room per 24 residents.Movable wall.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( x ) Cable TV ( x )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 1

Page 277: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 530

Room Name LTC Country Kitchen

Net Area 200

Quantity 1

Adjacency LTC Activity Room

Floor Finish Sheet Vinyl

Wall Finish Paint

Base Vinyl

Ceiling Finish Painted GWB

Door Type Wood Pocket

Wall Construction CMU w/GWB

Casework Plam Wall Base & Top

Equipment Kitchen equipment including sink, stove, and full-size refrigerator.

Arch Notes Open to LTC Activity Room.Pass through countertop with 4 stools.

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Provide kitchen make-up air and exhaust system in accordance with Code.

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Refrigerator on emergency power.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 1

Page 278: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 531

Room Name LTC Activity Alcove (one person)

Net Area 180

Quantity 1

Adjacency

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes 1 LTC Activity Alcove per 24 residents.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 1

Page 279: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 532

Room Name LTC Spa / Bathing Room

Net Area 230

Quantity 2

Adjacency LTC Home Base and Resident Corridor.

Floor Finish Rubber

Wall Finish Ceramic Tile 1/2 Ht.

Base Ceramic

Ceiling Finish 2 x 2 ACT

Door Type Wood DBL

Wall Construction Metal Stud w/GWB

Casework

Equipment Ceiling lift-track system ("voyager" style).Podiatric sink.Recumbent, fast-fill tub, usable from ceiling or hydraulic lift.

Arch Notes 1 Spa / Bathing Rm per 12 residents.No-wall shower (floor drain and sanitary walls).Provide pull-down "Lalido" bars at toilet, and standard grab bars elsewhere as required.Provide exterior window and appropriate window treatment for natural light.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( x ) Shower ( x ) Soak Tub ( x ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Include Nurse Call device and emergency phone.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 1

Page 280: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 533

Room Name LTC Nourishment Center

Net Area 100

Quantity 1

Adjacency LTC Home Base

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework Plam Wall Base & Top

Equipment Kitchenette with full-size refrigerator, microwave, and ice machine.

Arch Notes Tables and seating for 4.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 76 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Provide receptacles on standby power for refrigerator and kitchenette.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes: Provide lighting on standby power.

Per IESNA

May 21, 2007AFRH Gulport RFP Option 1

Page 281: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 534

Room Name LTC Workstation

Net Area 80

Quantity 1

Adjacency Locate along public corridor near Long Term Care Unit Entrance.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL w/Side Lite

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Secretarial workstation.Functions as reception area for Long Term Care Offices.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

May 21, 2007AFRH Gulport RFP Option 1

Page 282: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 534

Room Name LTC Public Toilet Room

Net Area 70

Quantity 2

Adjacency

Floor Finish Seamless Vinyl

Wall Finish Paint

Base Integral Coved Base"

Ceiling Finish Painted GWB

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework Plam Base & Top

Equipment Provide complete stainless steel toilet accessories.

Arch Notes 1 Public Toilet Room per 12 residents.Provide accessible water closet and sink.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( x ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control NoneCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Include Nurse Call device and emergency phone.

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 1

Page 283: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 535

Room Name LTC Clean Linen

Net Area 120

Quantity 2

Adjacency LTC Home Base.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment Provide Industrial-grade solid shelving.

Arch Notes 1 Clean Supply Room per 12 residents.Storage for "full" and "empty" containers, 8-12 "E" tanks.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 1

Page 284: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 536

Room Name LTC Soiled Linen / Trash Room

Net Area 120

Quantity 2

Adjacency LTC Home Base.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment Provide Industrial-grade solid shelving.

Arch Notes 1 Soiled Linen / Trash Room per 6 residents.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Provide 100% exhaust from space. No recirculation allowed.

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 1

Page 285: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 537

Room Name LTC Medical Supply Storage

Net Area 80

Quantity 2

Adjacency LTC Medical Waste Storage

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 4 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 1

Page 286: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 538

Room Name LTC Medical Waste Storage

Net Area 24

Quantity 2

Adjacency

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework

Equipment Provide Industrial-grade solid shelving.

Arch Notes 1 Medical Waste Storage Room per 12 residents.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Provide 100% exhaust from space. No recirculation allowed.

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 1

Page 287: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 539

Room Name LTC Medication Room

Net Area 110

Quantity 2

Adjacency LTC Home Base.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework Plam Base & Top

Equipment Full-size refrigerator.

Arch Notes 1 Medication Room per 12 Residents.Includes handwashing station and lockable storage units.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes Refrigerator for medications.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes: Minimal lighting for emergency access to refrigerator.

Per IESNA

May 21, 2007AFRH Gulport RFP Option 1

Page 288: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 540

Room Name LTC Laundry Room

Net Area 100

Quantity 2

Adjacency LTC Home Base.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/Impact Res. GWB

Casework Plam Wall Base & Top

Equipment Commercial-grade Washer / Dryer and deep stockable front load. ADA-accessible sink.Provide Industrial-grade solid shelving.Warpool system for drying and "steaming" equipment

Arch Notes 1 Laundry Room per 24 residents.Include table for folding laundry, clothes rod, and 2 chairs.Provide special ventilation and acoustical treatment.Water temperature booster in laundry rooms for one of washer --controlled by staff.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Provide utility sink.Provide special floor drain to accommodate washer overflow.

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( x )

Power Notes

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( x ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 1

Page 289: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 541

Room Name LTC Lift Storage

Net Area 100

Quantity 1

Adjacency Internal corridor.

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood DBL

Wall Construction Metal Stud w/Impact Res. GWB

Casework

Equipment Provide Industrial-grade solid shelving.

Arch Notes Provide storage for five wheelchairs, two lifts (3' x 3'), and general storage for other equipment.

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 1

Page 290: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 542

Room Name LTC Chart Room

Net Area 120

Quantity 1

Adjacency LTC Home Base

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment To be determined with AFRH staff.

Arch Notes

Temp F (Winter) 70 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 1

Page 291: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 543

Room Name LTC Day / Visitor Room

Net Area 200

Quantity 1

Adjacency LTC Home Base

Floor Finish Carpet 36 oz

Wall Finish Paint & FWC

Base Vinyl

Ceiling Finish Painted GWB

Door Type Wood DBL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( x ) Access Control NoneCCTV ( ) Cable TV ( x )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency room.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 1

Page 292: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 544

Room Name LTC Staff Break Area

Net Area 150

Quantity 2

Adjacency LTC Staff Toilets

Floor Finish VCT

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment Half-height lockers for 16 employees.Kitchenette with full-size refrigerator.

Arch Notes 1 Staff Break Area per 24 residents.Tables and chairs for 6.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 1

Page 293: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 545

Room Name LTC Staff Toilet

Net Area 70

Quantity 2

Adjacency LTC Home Base

Floor Finish Ceramic Tile

Wall Finish Ceramic Tile Wet Wall

Base Ceramic

Ceiling Finish Painted GWB

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework Plam Base & Top

Equipment Provide complete stainless steel toilet accessories.

Arch Notes ADA accessible watercloset and sink.1 Men assigned.1 Women assigned.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( x ) Toilet ( x ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Privacy SetCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 1

Page 294: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 546

Room Name LTC Clinical Supervisor

Net Area 120

Quantity 1

Adjacency LTC Scial Woorker

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 1

Page 295: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 547

Room Name LTC Medical Records Technician

Net Area 80

Quantity 1

Adjacency Locate along public corridor.Adjacent to Long-Term Care Unit Entrance.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL w/Side Lite

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Secretarial workstation.Functions as reception area for Long-Term Care Offices.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 1

Page 296: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 548

Room Name LTC Nurse Practitioner

Net Area 120

Quantity 1

Adjacency LTC Workstation and LTC Office Coordinator.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 1

Page 297: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 549

Room Name LTC Dietician

Net Area 120

Quantity 1

Adjacency LTC Clinical Supervisor

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 1

Page 298: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 550

Room Name LTC Social Worker

Net Area 120

Quantity 1

Adjacency LTC Clinical Supervisor and LTC Medical Records Technician.

Floor Finish Carpet 32 oz

Wall Finish Paint

Base Vinyl

Ceiling Finish 2 x 2 ACT

Door Type Wood SGL

Wall Construction Metal Stud w/GWB

Casework

Equipment

Arch Notes Standard desk and credenza with 2 visitor chairs.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 75 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 1

Page 299: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007

General Services Administration Public Buildings Service Southeast Sunbelt Region Real Estate Design and Construction

UNCLASSIFIED

OPTION 2

Page 300: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 701

Room Name Pool(s) and Deck

Net Area

Quantity 1

Adjacency General Swimming Area.

Floor Finish TBD

Wall Finish

Base None

Ceiling Finish No Ceiling

Door Type

Wall Construction

Casework

Equipment Standard pool equipment including ladders, ropes, and life guard station.

Arch Notes Provide 25 meter lap pool with 8 lanes.Chaise lounges, tables, and chairs for 40-50 people.Provide "Cool Deck" finish surrounding pool.

Temp F (Winter)

Temp F (Summer)

% R Humidity (Winter)

% R Humidity (Summer)

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control NoneCCTV ( x ) Cable TV ( )

Tele Data Special Requirements

Provide emergency phone.

Sprinkler

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.Provide connections for food service equipment.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes: Underwater pool lighting and decorative fixtures for nighttime use.

Per IESNA

May 21, 2007AFRH Gulport RFP Option 2

Page 301: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 702

Room Name Dressing Area

Net Area 750

Quantity 2

Adjacency Pool(s) and Deck

Floor Finish Rubber

Wall Finish Paint

Base Vinyl

Ceiling Finish Painted GWB

Door Type Metal SGL

Wall Construction CMU

Casework

Equipment

Arch Notes Provide Men's and Women's locker / toilet rooms.Provide 40 -50 half-height lockers (no metal) and benches.Include 2 showers, 3 water closets (or equivalent) and2 sinks in each room.Provide direct outside access to pool.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 60%

Special HVAC Requirements

Sink ( x ) Toilet ( x ) Shower ( x ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( x ) Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Provide dry pipe system if located in outbuilding.

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 2

Page 302: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 703

Room Name Sunning Area / Outdoor Terrace

Net Area

Quantity 1

Adjacency Pool(s) and Deck

Floor Finish TBD

Wall Finish

Base TBD

Ceiling Finish

Door Type

Wall Construction

Casework

Equipment

Arch Notes Provide "Cool Deck" floor finish.Chaise lounges, tables, and chairs for 20-25 people.

Temp F (Winter)

Temp F (Summer)

% R Humidity (Winter)

% R Humidity (Summer)

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control NoneCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 2

Page 303: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 704

Room Name Mechanical Room / Pool Eqpt.

Net Area 400

Quantity 1

Adjacency Swimming Pool.

Floor Finish Sealed Concrete

Wall Finish Paint

Base None

Ceiling Finish No Ceiling

Door Type Metal DBL

Wall Construction CMU

Casework

Equipment Pool Equipment

Arch Notes

Temp F (Winter)

Temp F (Summer)

% R Humidity (Winter)

% R Humidity (Summer)

Special HVAC Requirements

Venitlation only (per Code).

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Provide safety shower.

Voice ( x ) Data ( ) Audio-Video ( ) Access Control Key OnlyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Provide dry pipe system if located in outbuilding.

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 2

Page 304: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 705

Room Name Pool Office

Net Area 144

Quantity 1

Adjacency Swimming Pool.

Floor Finish Sealed Concrete

Wall Finish Paint

Base Vinyl

Ceiling Finish Painted GWB

Door Type Metal SGL

Wall Construction CMU

Casework

Equipment Include observation window facing pool.

Arch Notes

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 60%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Provide dry pipe system if located in outbuilding.

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 2

Page 305: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 706

Room Name Recreational Storage

Net Area 180

Quantity 1

Adjacency

Floor Finish Sealed Concrete

Wall Finish Paint

Base None

Ceiling Finish No Ceiling

Door Type Metal DBL

Wall Construction CMU

Casework

Equipment

Arch Notes

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 60%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( x ) Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( x ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Provide dry pipe system if located in outbuilding.

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 2

Page 306: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 707

Room Name Patio Cookout Storage

Net Area 100

Quantity 1

Adjacency

Floor Finish Sealed Concrete

Wall Finish Paint

Base None

Ceiling Finish No Ceiling

Door Type Metal DBL

Wall Construction CMU

Casework

Equipment

Arch Notes

Temp F (Winter)

Temp F (Summer)

% R Humidity (Winter)

% R Humidity (Summer)

Special HVAC Requirements

Ventilation only.

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Provide dry pipe system if located in outbuilding.

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 2

Page 307: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 708

Room Name Chemical Storage

Net Area 200

Quantity 1

Adjacency Mechanical Room / Pool Eqpt.

Floor Finish Sealed Concrete

Wall Finish Paint

Base None

Ceiling Finish No Ceiling

Door Type Metal DBL

Wall Construction CMU

Casework

Equipment

Arch Notes

Temp F (Winter)

Temp F (Summer)

% R Humidity (Winter)

% R Humidity (Summer)

Special HVAC Requirements

Ventilation only (per Code).

Sink ( x ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( x )

Spec Plumb Requirements

Provide safety shower.

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Provide dry pipe system if located in outbuilding.

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 2

Page 308: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 709

Room Name Table Storage

Net Area 500

Quantity 1

Adjacency

Floor Finish Sealed Concrete

Wall Finish Paint

Base None

Ceiling Finish No Ceiling

Door Type Metal DBL

Wall Construction CMU

Casework

Equipment

Arch Notes

Temp F (Winter)

Temp F (Summer)

% R Humidity (Winter)

% R Humidity (Summer)

Special HVAC Requirements

Ventilation only.

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Provide dry pipe system if located in outbuilding.

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 2

Page 309: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 710

Room Name Activity Storage Room

Net Area 400

Quantity 1

Adjacency

Floor Finish Sealed Concrete

Wall Finish Paint

Base None

Ceiling Finish No Ceiling

Door Type Metal DBL

Wall Construction CMU

Casework

Equipment

Arch Notes

Temp F (Winter)

Temp F (Summer)

% R Humidity (Winter)

% R Humidity (Summer)

Special HVAC Requirements

Ventilation only.

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Not on emergency system.

Include on Emergency Power Genset ( )

Power Notes Provide dry pipe system if located in outbuilding.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 2

Page 310: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 711

Room Name Open Exercise Room

Net Area 2000

Quantity 1

Adjacency

Floor Finish Sprung Wood

Wall Finish Paint

Base Wood

Ceiling Finish 2 x 4 ACT

Door Type Glass DBL

Wall Construction CMU w/GWB

Casework

Equipment Exercise floor mats.

Arch Notes Low-impact exercises typical.Provide special ventilation and acoustical treatments.Include wall mirrors and balance bars.

Temp F (Winter) 72 Deg (F)

Temp F (Summer) 78 Deg (F)

% R Humidity (Winter) 30%

% R Humidity (Summer) 50%

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( x ) Data ( x ) Audio-Video ( x ) Access Control Card Access w/KeyCCTV ( x ) Cable TV ( x )

Tele Data Special Requirements

Include emergency phones and AED (electronically monitored by security).

Sprinkler Std Wet System

Fire Suppression Notes

Provide dry pipe system if located in outbuilding.

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 2

Page 311: APPENDIX A – ROOM DATA SHEETS - USM...APPENDIX A – ROOM DATA SHEETS Armed Forces Retirement Home Design Build Services Request for Proposal Gulfport, Mississippi 21 May 2007 General

Room Data Sheet Armed Forces Retirement Home

Gulfport, Mississippi

Room Number 712

Room Name Storage

Net Area 500

Quantity 1

Adjacency

Floor Finish Sealed Concrete

Wall Finish Paint

Base None

Ceiling Finish No Ceiling

Door Type Metal DBL

Wall Construction CMU

Casework

Equipment

Arch Notes

Temp F (Winter)

Temp F (Summer)

% R Humidity (Winter)

% R Humidity (Summer)

Special HVAC Requirements

Sink ( ) Toilet ( ) Shower ( ) Soak Tub ( ) Floor Drain ( )

Spec Plumb Requirements

Voice ( Data ( ) Audio-Video ( ) Access Control Card Access w/KeyCCTV ( ) Cable TV ( )

Tele Data Special Requirements

Sprinkler Std Wet System

Fire Suppression Notes

Provide dry pipe system if located in outbuilding.

Include on Emergency Power Genset ( )

Power Notes Not on emergency system.

SF

EA

Program Space

Architectural

Mechanical

Plumbing

Technology, Telecomunications Security

Fire Suppression System

Power

Lighting On Generator: ( ) Avg Maintained Level (fc):

Fixture Types: Switching: Standard

Lighting Notes:

Per IESNA

May 21, 2007AFRH Gulport RFP Option 2