Guidance of setting vehicle-detector
1.DetailsVehicle-detector type: F6213H/LModule-manufacturer: Quectel Wireless Solutions Co.,Ltd.Module type:BC95
2.Preparation Monitor machine (F6213T) Computer that has installed F6213_tool
3.Software instructions3.1 Interface specification
3.2 Button specificationSerial PortThe drop-down window: select real portOpen: click and open serial portVehicle detector ID
ID: To send commands of vrhicle-detector ID( vehicle-detector get into set
mode,it will fiil id automatically)ID Mask: When fill 0x00000000 with blank, it works all vehicle-detector in effective range.
When fill 0xFFFFFFFF with blank,the commands just works the goal Vehicle detector
Guidance of setting vehicle-detector
Freq: vehicle monitor frequency(ranng 0-80)Set debug freq: set the frequency brtween vrhicle-detector and monitor machineSet debug freq 0: set monitor frequency is 0
One Key Set freq:one key set monitor frequency
One Key Set freq 0: one key set monitor frequency is 0synchronize time: synchronize time between vehicle-detector and computerID: write a id to vehicle-detectorSet New ID: reset a id to vehicle-detectorSet Carport Occupied: set the carport status is occupiedSet Carport Unoccupied: set the carport status is unoccupied
X/Y/Z: collect geomagnetic value(the function is not exist)Set Vehicle Init Value: set vehicle-detector initial value( the function is not
exist)Start work: vehicle-detector get into work mode
Monitor BoardFreq: the monitor working frequency
Baud:the rate between monitor and vehicle-detector (Baud=1M)
Set monitor freq: set monitor frequencyTest: test communication status between monitor and vehicle-detector(the function is not exist)ProductionStep1: Set Vehicle Into Set ModuleStep2: Set Vehicle Production FreqStep3: Read NB-IOT ModuleStep4: Into Update NB-IOT Module: Set module get into set modeStep5: Update NB-IOT ModuleStep6: Set Lisa UUID/IMEI/IMSStep7: Check Lisa UUID/IMEI/IMSIStep8: Reset Vehicle Production FreqNB-IOT Module
EARFCN: E-UTRA Absolute Radio Frequency Channel Number
COPS/PLMN: Public Land Mobile Network
PLMN = MCC(mobile country code ) + MNC(mobile network code ) APN: Access Point Name IoT address: IoT platform southern ip addressAT commmands
Guidance of setting vehicle-detector
Commands Function RemarkAT+CGMR Query module version The lastest version
is: B656SP2AT+CGSN=1 QueryIMEIAT+NTSETID=1, Reset IMEIAT+CIMI Query SIM-card’s IMSIAT+NCONFIG=AUTOCONNECTAT+NCDP= Set IoT southern ip
addressAT+COPS=1,2,AT+NUESTATS
Remarks:AT commands have different syntax,please refer to AT commands manusal
Button specification Button “Clear”
Clear interface Button “SAVE WINDOWS”
Save interface Button “Open Path”
Open logs saving path Button “Open Firmware”
Option the firmware that is needed to update Button“Enter set mode”
Send command to make vehicle-detector get into set mode Button “Update”
Choose firmware and finish updating Botton “One Key Update”
Choose firmware to finish Button “Any One Key Update”
Choose firmware to finish Button “Any Enter set mode”
Set vrhicle-detector get into set mode (it is used to commmunicate in short range )
Button “ Start work” Set vehicle-detector get into work mode
Button “Set ID=0” Set id =0,vehicle-detector getting into sleep mode3.3 Setting specification3.3.1 NB-IoT vehicle-detector modes
Sleep mode Set mode Work mode
3.3.2 Set vehicle-detector into set mode
Guidance of setting vehicle-detector
Known id1.Power on vehicle-detector,filling right id and id-mask with blank
2.Click “Enter set mode”
Unknown id
Put monitor machine under vehicle-detector, click “Any enter set mode”,it will return
success.
Guidance of setting vehicle-detector
3.3.3 Set vehicle-detector IDSet vehicle-detector get into set mode ->>fills id (this id has established in
website)->>click “set new id ”
Guidance of setting vehicle-detector
3.3.4 Set communication frequencySet vehicle-detector get into set mode-->fills frequency-->>click “set debug freq”
3.3.5 Click “start work”,vehicle-detector get into work modeFinish setting, set vehicle-detector get into work mode
3.3.6 Set UE attach network paramters
Guidance of setting vehicle-detector
AT+CFUN=0
AT+NCDP=112.93.129.154
AT+COPS=1,2,"65501"
Guidance of setting vehicle-detector
AT+NBAND=5
Set NB EARFCN
Guidance of setting vehicle-detector
Set frequency-point between module and NB station,if there is no need to lock on frequendy,please fills “NONE_NEARFCN”with blank.
Set NB CPOSIf thers is no need to fill COPS,please fills “NONE_CPOS”with blank
Set NB APN.
Guidance of setting vehicle-detector
Set IoT paltform southern Addr.
Set network paramters successfully,click “start work ”to attach NB network
Guidance of setting vehicle-detector