Upload
vonhi
View
224
Download
6
Embed Size (px)
Citation preview
Energy
– MVR evaporators: 6-fold increased efficiency. – High pressure boilers (30 bars – 450 psig) to substitute electric motors
with turbines on evaporators. – Elimination of cooling towers with open air ponds. – Tomatos unloading from an elevation (hill) to avoid elevators. – Coupled finishers powered by turbines.
Co generation
– High efficiency motors and VFDs*. – Thermal insulation of pipes and exchangers.
Waste and water
– Turbo presses for waste recovery. – WISE water transport circuit.
Steam line 10 bar 16.800 kg/h
Steam inlet 4 bar2.537 kg/h with Apollo
8.750 kg/h without Apollo
Steam inlet 4 bar3.383 kg/h with Apollo
11.670 kg/h without Apollo
Tomato juice inlet 5,2° Brix 118.364 kg/h
Tomato paste outlet 29,5° Brix8.693 kg/h
Tomato paste outlet 29,5° Brix12.171 kg/h
Tomato juice collection tank
Low pression
line
Pre-evaporator Apollo 4FF (Evaporated water: 37.500 kg/h)
Evaporator Venus T70 TE(Evaporated water: 25.000 kg/h)
Evaporator Manzini MV 1000.4(Evaporated water: 35.000 kg/h)
5,2°BRIX
2 BAR
7,6°BRIX
1
1 2 3 4
2 3
Effects in parallel
2.300 kg/h
80.864 kg/h
33.6
93 k
g/h
47.1
70 k
g/h
8.750 kg/h
11.670 kg/h
Pre-concentratedjuice tank7,6° Brix
MVR (Mechanical Vapors Recompression) uses a
centrifugal fan, driven by either an electric motor or a
steam turbine, to re-compress the vapors from separation
chamber thus increasing their enthalpy and allowing their
use as heating medium in the exchanger.
In the recent past we have proposed Apollo MVR evaporator as a first
stage of evaporation in conjunction with a standard triple effect Forced Flow
evaporator acting as finisher.
Today we can supply a complete range of Apollo pre-evaporators:
APOLLO + FINISHER EVAPORATOR = 25€/t
Steam in
Product in
Product out
1234
Steam in
Steam out
1
2
3
4
– Virtually no steam needed for heating. – Exhaust steam from turbine recovered in downstream
evaporators. – Evaporation efficiency up to 1:20. – CFT technology: APOLLO falling film evaporator and
centrifugal fan at maximum 3,200 rpm as MVR.
How it works
Cost saving
Typical product line
Variable-frequency drive*
PRE-EVAPORATOR D.F.F. FINISHER WHOLE PLANT
Apollo 15 (15t/h WR)
Apollo 25 (25t/h WR)
Apollo 40 (40t/h WR)
Apollo 60 (60t/h WR)
T1800 (20t/h WR)
T1800 (30t/h WR)
T1800 (50t/h WR)
T1800 (70t/h WR)
1100t/day
1700t/day
2700t/day
3300t/day