33
APIS COR Boston,MA 3D PRINTED STRUCTURES AS COMPARABLE TO MASONRY CONSTRUCTION 2019 INTRODUCTION Construction 3D printing technology is an approach to building wall structures by means of a robotic system that extrudes layer-by-layer high viscosity materials based on cement, gypsum, geopolymer, or other binders. This approach is regarded as a promising and innovative construction method, with many 3D printed buildings around the world serving as examples. However, there is still no single well-documented standard of 3D printed structures that can be approved for residential construction, complying with international building codes and construction requirements. This report introduces a special configuration of 3D printed structures, comparable to the well- documented and accepted method of reinforced concrete masonry unit (CMU) construction. By matching our 3D printed walls with the (CMU) wall all construction techniques employed in roofing, foundation, etc., can be the same as used for CMU. CMU construction employs a pattern of concrete blocks conducive to 3D printing and well- documented construction techniques. CMUs comprise a significant percentage of the American residential foundation wall market and have a long history of above-grade residential use in Arizona, Florida, Texas, and other parts of the southern United States. The goal of this document is to demonstrate structural similarity between 3D printed walls and CMU walls, which may serve as a possible simplification in the permitting process for 3D printed buildings. This document is an independent research done by Apis Cor company. Information presented in the document is subject to ongoing evaluation, development, and acceptance by an appropriate approving agency.

APIS COR Boston,MA

  • Upload
    others

  • View
    9

  • Download
    0

Embed Size (px)

Citation preview

Page 1: APIS COR Boston,MA

APIS COR Boston,MA

3D PRINTED STRUCTURES AS COMPARABLE TO MASONRY CONSTRUCTION

2019

INTRODUCTION

Construction 3D printing technology is an approach to building wall structures by means of a

robotic system that extrudes layer-by-layer high viscosity materials based on cement, gypsum,

geopolymer, or other binders. This approach is regarded as a promising and innovative construction

method, with many 3D printed buildings around the world serving as examples. However, there is still

no single well-documented standard of 3D printed structures that can be approved for residential

construction, complying with international building codes and construction requirements.

This report introduces a special configuration of 3D printed structures, comparable to the well-

documented and accepted method of reinforced concrete masonry unit (CMU) construction. By

matching our 3D printed walls with the (CMU) wall all construction techniques employed in roofing,

foundation, etc., can be the same as used for CMU.

CMU construction employs a pattern of concrete blocks conducive to 3D printing and well-

documented construction techniques. CMUs comprise a significant percentage of the American

residential foundation wall market and have a long history of above-grade residential use in Arizona,

Florida, Texas, and other parts of the southern United States.

The goal of this document is to demonstrate structural similarity between 3D printed walls and

CMU walls, which may serve as a possible simplification in the permitting process for 3D printed

buildings.

This document is an independent research done by Apis Cor company. Information presented in

the document is subject to ongoing evaluation, development, and acceptance by an appropriate

approving agency.

Page 2: APIS COR Boston,MA

APIS COR Boston,MA

2

TABLE OF CONTENTS

SECTION 1: Specification of 3D printed wall .................................................................................................. 3

SECTION 2: Material testing ............................................................................................................................ 6

SECTION 3: Design ........................................................................................................................................ 13

SECTION 4:Construction solutions ................................................................................................................ 16

EXIBIT 1: Report on ASTM C39 testing by Briggs Engineering & Testing ............................................ 20

EXIBIT 2: Report on ASTM C39 testing by UConn .................................................................................. 22

EXIBIT 3: Report on ASTM C1314 testing by Briggs Engineering & Testing ....................................... 25

EXIBIT 4: Report on ASTM C1314 testing by Briggs Engineering & Testing ....................................... 26

EXIBIT 5: Report on ASTM C1314 testing by Briggs Engineering & Testing ....................................... 27

EXIBIT 6: Report on ASTM C642 testing by Briggs Engineering & Testing .......................................... 28

EXIBIT 7: Report on ASTM C293 testing by UConn ................................................................................ 29

Page 3: APIS COR Boston,MA

APIS COR

3

Boston,MA SECTION 1

SPECIFICATIONS OF 3D PRINTED WALL

This section introduces the design of a 3D printed wall that mimics a 2 -hour fire rating masonry

wall, constructed with 8x8x16 masonry blocks.

Structural similarities of the proposed 3D printed wall and the CMU wall are shown in Figure 1. The

physical parameters of the proposed 3D printed wall are displayed next to the minimum requirements

for the equivalent CMU constructed wall in Table 1. Table 2 presents the material properties of a 3D

printed wall.

Material tests were performed by Briggs Engineering and Testing and The University of Connecticut,

in accordance with ASTM testing standards.

Wall formation. Cement-based 3D printing material is extruded using a robot arm to form the wallā€™s

foundation, layer by layer. Reinforcement, bars, and mesh are installed manually concurrently with the

3D printing. Grout and concrete are cast manually into columns and bond beams.

Briggs Engineering & Testing is regularly audited and/or certified by the the National Institute of

Standards and Technology's Cement and Concrete Laboratory (CCRL), the Nuclear Regulatory

Commission (NRC), the Federal Aviation Administration (FAA), the US Army Corps of Engineers, the

American Association of State Highway and Transportation Officials (AASHTO) and the New

England Transportation Technician Certification Program (NETTCP). Briggs Engineering & Testing

also licensed or pre-qualified by all applicable state agencies such as the Massachusetts Highway

Department (MHD) and the Massachusetts Bay Transit Authority (MBTA). Our State Certified

Materials Laboratory and testing equipment is current and state of the art.

The University of Connecticut - a top-ranked research institution, campuses across Connecticut, US

built to inspire, the global community that is UConn Nation.

Figure 1.Structural similarity between 3D printed wall and CMU wall.

Page 4: APIS COR Boston,MA

APIS COR Boston,MA

4

Figure 2a. Dimensions of wall segment

Page 5: APIS COR Boston,MA

APIS COR Boston,MA

5

Table 1. Physical parameters of 1-hour rating 3D printed wall compared to masonry:

Parameter 3D printed wall Minimum requirement for CMU

Aggregate type in

wall material

siliceous gravel accepted

Material as lightweight

masonry

Equivalent

thickness

4.5 in. 2.8 in

Net Area

compressive

strength (ASTM

C1314)

2,350 Psi

comply

2,000 Psi

Column size 8х10 inches 8х8 inches

Minimum cover

for R/C columns

comply The minimum required cover over the vertical

reinforcement is 2 in. (51 mm).

Bar size as required as required

Bar placement in

terms of corrosion

protection

comply masonry exposed to weather or earth

bars

larger than No. 5 (M#16) ā€¦ā€¦ā€¦ā€¦.2 in. (51 mm)

No. 5 (M#16) bars or smallerā€¦ā€¦ā€¦ā€¦...ā€¦1Ā½ in. (38 mm)

masonry not exposed to weather or earth ā€¦ 1Ā½ in. (38 mm)

Joint reinforcement comply Ā½ inch (13 mm) from edge of internal wall

ā… inch (16 mm) from edge of external wall

Table 2. Material properties of a 3D printed wall units Test Value Testing Laboratory

Absorption 17,1 % Briggs Engineering and

Testing

2 Density material 101.3 lb/ft3 Briggs Engineering and

Testing; 3 Average compressive strength of material (kept in

normal conditions) on 28 day (ASTM C39) 3,627 Psi Briggs Engineering and

Testing; University of Connecticut

4 Average compressive strength of material (kept in

water) on 28 day (ASTM C39) 2,880 Psi Briggs Engineering and

Testing

5 NET area compressive strength test of hollow 3D

printed wall unit (ASTM C1314) 2,350 Psi Briggs Engineering and

Testing; University of Connecticut

6 NET area compressive strength test of grouted 3D

printed wall unit (ASTM C1314) 3,010 Psi Briggs Engineering and

Testing 7 3 point flexural test (Modulus of Rapture) 406 Psi University of Connecticut

Page 6: APIS COR Boston,MA

APIS COR Boston,MA

6

SECTION 2

MATERIAL TESTING

1. Material compressive strength.

Compressive strength testing was conducted for the 3D printed material, in accordance with

standard ASTM C39 procedures. Although 3D printed structures are constructed in normal conditions,

two series of material specimens were tested: specimens kept in normal conditions and specimens kept

in water. Specimens were removed from the water storage immediately prior to testing.

Table 3 displays the average compressive strength of both specimens; Chart 1 demonstrates the

development of compressive strength over time for samples kept in normal conditions; Chart 2 shows

the development of compressive strength over time for samples kept in water and taken prior to the

testing; and Figure 2 demonstrates the specimens before and after testing.

Table 3. Average compressive strength. Reports presented in Exhibit 1 and Exhibit 2.

Kept in AIR Kept in WATER

Compressive strength, Psi Compressive strength, Psi

AGE

1

sample

2

sample

3

sample Average

1

sample

2

sample

3

sample Average

1 day 420 380 400 400 420 390 380 397

2 days 1,230 1,240 1,220 1,230 780 840 770 797

7 days 2,150 2,360 2,470 2,327 1,960 1,950 1,850 1,920

28 days 3,590 3,510 3,780 3,627 3,030 2,790 2,820 2,880

90 days 3,890 4,160 4,410 4,153 3,630 3,280 3,740 3,550

Chart 1. Development of compressive strength over time for samples kept in normal

conditions.

Page 7: APIS COR Boston,MA

APIS COR Boston,MA

7

Chart 2. Development of compressive strength over time for samples kept in water.

Figure 3. Specimens before and after compressive strength testing.

Page 8: APIS COR Boston,MA

APIS COR Boston,MA

8

2. NET area compressive strength of units

Hollow and grouted pieces sawed from a 3D printed wall structure were subject to compressive

strength testing, according to standard ASTM C1314 procedures. The same test procedure was

conducted with CMU blocks to compare the performance. Core fill grout from Spec Mix with strength

of 3,000 Psi (ASTM C476) was used as grouting material. The test results are shown in Table 4. Figure

3 demonstrates the process of sawing the specimens from the 3D printed wall, Figure 4 and Figure 5

demonstrates the prototype of 3D printed wall as comparable to masonry, Figure 6 demonstrates

specimens. Figure 7 demonstrates the hollow 3D printed specimen before and after the testing. Figure 8

and Figure 9 demonstrates 3D printed specimens and masonry units under the load.

Table 4. The report presented in Exhibits 3-5. 3D printed CMU

Hollow units 2,495 Psi (average of 2 samples) 1,740 Psi

Grouted units 3,010 Psi 3,690 Psi

Fig.3 Sawing the specimens from the 3D printed wall

Fig.5 The prototype of 3D printed wall as comparable to

masonry

Fig. 4 The prototype of 3D printed wall as

comparable to masonry

Page 9: APIS COR Boston,MA

APIS COR Boston,MA

9

Fig. 6 Grouted and hollow specimens

Fig. 7 The hollow 3D printed wallā€™s sample before and after compressive strength test.

Fig. 8 The grouted (left) 3D printed wallā€™s unit and hollow (right) 3D printed wallā€™s unit after the test.

Page 10: APIS COR Boston,MA

APIS COR Boston,MA

10

3. Absorption and density

Two material specimens with measurements of 4x3x16 in. were subject to absorption testing, according to

the ASTM C642 procedure. The results of the testing are shown in Table 5.

Table 5. The report presented in Exhibit 6. Maximum Absorption, % Density, dry, pcf

Sample 1 16,8 101,6

Sample 2 17,3 101,0

Average 17,1 101,3

According to ASTM C90 units of 3D printed wall corresponds to Lightweight masonry units. Having

average net area compressive strength as 2, 495 Psi, units of 3D printed wall comply with minimum

NET area compressive strength for Lightweight masonry which is 2,000 Psi.

4. 3-points flexural test

Table 6. Modulus of rapture. The report presented in Exhibit 7.

3D printed Solid

Sample 1 Sample 2 Sample 3 Average Sample 1 Sample 2 Sample 3 Average

Value,

MPa

2.56 2.67 3.16 2.80 2.49 4.64 4.90 4.01

Fig. 9 The hollow (left) masonry unit and grouted (right) 3D printed wallā€™s sample after the test.

To check if 3D printed structures have cold joints, 3-points flexural test were conducted. 3 beams were sawed from a 3D printed wall, then the corrugated surface was sawed so that the specimens had straight surfaces for testing purposes. Meanwhile, 3 solid beams were cast with the same 3D printing mix design, to compare the results between the solid and 3D printed beams. Solid beams were tested at 28 days of age, and 3D printed beams were tested at 95 days of age. The test results are displayed in Table 6. Figures 10 - 14 demonstrate the preparation process of the specimens and testing process, Figures 15 demonstrates the cracking pattern for the printed beams and solid beams.

Page 11: APIS COR Boston,MA

APIS COR Boston,MA

11

Fig. 10 Sawing the 3D printed specimens Fig.11 Casting the solid specimens

Fig. 12 The 3D printed specimens before and after sawing the corrugated surface

Fig. 13 The 3D printed and solid specimens ready for

testing Fig. 14 The 3D printed sample under the load

Page 12: APIS COR Boston,MA

APIS COR Boston,MA

12

Fig. 15 A visual representation of the cracking pattern for the printed beams a) to c) and the solid beams d) to f).

Test results demonstrated that beams sawed from a 3D printed wall do not have cold joints.

Page 13: APIS COR Boston,MA

APIS COR Boston,MA

13

SECTION 3

DESIGN

This section verifies the design similarities between a 3D printed wall and a 1-hour rating masonry

wall assembled out of 8x8x16 in. concrete blocks. This section is based on the provision in Chapter 7

of the International Building Code (IBC) that governs materials and assemblies used for structural fire

resistance.

1. Equivalent thickness

Equivalent thickness is essentially the solid thickness that would be obtained if the volume of concrete

contained in a hollow unit were recast without core holes (see Figure 16).

Fig.16 Equivalent thickness of masonry unit Fig.17 Equivalent thickness of 3D printed

Equivalent thickness of a 3D printed unit is 4.5 in. (see Figure 17), which complies with 2 -hour fire resistance masonry unit made of material with siliceous gravel as an aggregate type, as

shown in Table 7.

Page 14: APIS COR Boston,MA

APIS COR Boston,MA

14

2. Column sizes

Masonry: for columns made with concrete having a specified compressive strength (f 'c) of less than or

equal to 12,000 Psi (82.7 MPa), the minimum dimensions shall comply with Table 722.2.4 of IBC:

Table 722.2.4 of IBC: MINIMUM DIMENSION OF CONCRETE COLUMNS (inches)

TYPES OF CONCRETE

FIRE-RESISTANCE

RATING (hours)

1 11/2 2a 3a 4b

Siliceous 8 9 10 12 14

Carbonate 8 9 10 11 12

Sand-lightweight 8 81/2 9 101/2 12

3D printed walls: Columns of 3D printed structures contain siliceous gravel as the aggregate type,

whether constructed of concrete or 3D printed material. The overall dimensions of the columns in 3D

printed walls are 8x10 in. Thus, columns of 3D printed structures comply with the requirements for a

1-hour fire resistance rating.

Reference: 722.2.4 of IBC

3. Minimum cover for R/C columns

Masonry: The minimum required cover over the vertical reinforcement is 2 in. (51 mm).

3D printed structures: Design of the 3D printed wall structure allows placement of the rebars in

compliance with this section.

Reference: 722.2.4.2 of IBC

4. Bar size

Masonry: Typical single wythe walls correspond to a maximum bar size of No. 8, 9, and 11 for 8-, 10-,

and 12- in. walls, respectively (M#25, 29 and 36 for 203-, 254- and 305-mm walls). In addition, the

following limits apply:

a) maximum bar size is No. 11 (M#36);

b) the area of vertical reinforcement may not exceed 6% of the grout space area (i.e. about 1.26

in.Ā², 1.81 in.Ā², or 2.40 in.Ā² of vertical reinforcement for 8-, 10-, and 12-in. concrete masonry,

respectively [815 mmĀ², 1,170 mmĀ², or 1,550 mmĀ² for 203-, 254- and 305-mm units,

respectively]); and

c) for masonry designed using strength design procedures, the maximum bar size is No. 9 (M#29)

and the maximum area of reinforcement is 4% of the cell area (i.e. about 0.84 in.Ā², 1.21 in.Ā², or

1.61 in.Ā² of vertical reinforcement for 8-, 10-, and 12-in. concrete masonry, respectively [545

mmĀ², 781 mmĀ², or 1,039 mmĀ² for 203-, 254-, and 305-mm units, respectively]).

3D printed structures: Design of the 3D printed wall structure allows selection of rebars in compliance

with this section

Reference: ā€œSTEEL REINFORCEMENT FOR CONCRETE MASONRYā€ issued by National

Concrete Masonry Association

https://ncma.org/resource/steel-reinforcement-for-concrete-masonry/

Page 15: APIS COR Boston,MA

APIS COR Boston,MA

15

5. Corrosion

Masonry: A minimum amount of masonry covering the reinforcing bars is required to protect against

steel corrosion. This masonry cover is measured from the nearest exterior masonry surface to the

outermost surface of the reinforcement, and includes the thickness of masonry face shells, mortar, and

grout. The following minimum cover requirements apply:

Masonry exposed to weather or earth

bars larger than No. 5 (M#16) ā€¦ā€¦ā€¦ā€¦ā€¦ā€¦ā€¦ā€¦.2 in. (51 mm)

No. 5 (M#16) bars or smallerā€¦ā€¦ā€¦ā€¦ā€¦ā€¦ā€¦ā€¦1Ā½ in. (38 mm)

Masonry not exposed to weather or earth ā€¦ 1Ā½ in. (38 mm)

3D printed structures: Design of the 3D printed wall structure allows placement of the rebars in

compliance with this section.

Reference: ā€œSTEEL REINFORCEMENT FOR CONCRETE MASONRYā€ issued by National

Concrete Masonry Association

https://ncma.org/resource/steel-reinforcement-for-concrete-masonry/

6. Joint reinforcement

Carbon steel can be protected from corrosion by coating the steel with zinc (galvanizing). The zinc

protects in two ways: first, as a barrier separating the steel from oxygen and water; and second, during

corrosion, the zinc is sacrificed before the steel is attacked. Increasing the zinc coating thickness

improves the level of corrosion protection. Required levels of corrosion protection increase with the

severity of exposure. When used in exterior walls or in interior walls exposed to a mean relative

humidity of over 75%, carbon steel joint reinforcement must be hot-dip galvanized or epoxy-coated, or

stainless-steel joint reinforcement must be used. When used in interior walls exposed to a mean relative

humidity less than or equal to 75%, it can be mill galvanized, hot-dip galvanized, or stainless steel can

be used. The corresponding minimum protection levels are:

ā€¢ Mill galvanizedā€”ASTM A 641 (ref. 16) 0.1 oz/ftĀ² (0.031 kg/mĀ²)

ā€¢ Hot-dip galvanizedā€”ASTM A 153 (ref. 17), Class B, 1.5 oz/ftĀ² (458 g/mĀ²)

ā€¢ Epoxy-coatedā€”ASTM A 884 (ref. 18) Class A, Type 1 ā‰„ 7 mils (175 Āµm) (ref. 3). Note that

both the 2003 IBC and 2002 MSJC code incorrectly identify Class B, Type 2 epoxy coated joint

reinforcement, which is not applicable for masonry construction.

Masonry: joint reinforcement must be placed so that longitudinal wires are embedded in mortar with a

minimum cover of:

Ā½ in. (13 mm) when not exposed to weather or earth

ā… in. (16 mm) when exposed to weather or earth.

3D printed structures: Design of the 3D printed wall structure allows placement of joint reinforcement

in compliance with this section.

Reference: ā€œSTEEL REINFORCEMENT FOR CONCRETE MASONRYā€ issued by National

Concrete Masonry Association

https://ncma.org/resource/steel-reinforcement-for-concrete-masonry/

Page 16: APIS COR Boston,MA

APIS COR Boston,MA

16

SECTION 4

CONSTRUCTION SOLUTIONS

Having structural similarity between 3D printed walls and masonry walls proven, all construction

techniques for 3D printed walls employed in roofing, foundation, etc., may be the same as used for

CMU. Figures 18-21a demonstrates the following construction solutions: foundation, bond beam,

installation a roof and lintels.

Fig.18 Foundation (CMU)

Fig.18a Foundation (3D printed wall)

Page 17: APIS COR Boston,MA

APIS COR Boston,MA

17

Fig.19 Bond Beam (CMU)

Fig.19a Bond Beam (3D printed wall)

Page 18: APIS COR Boston,MA

APIS COR Boston,MA

18

Fig.20 Lintels (CMU)

Fig.20 Lintels (3D printed wall)

Page 19: APIS COR Boston,MA

APIS COR Boston,MA

19

Fig.21 Bond Beam and Roof

(CMU)

Fig.21a Bond Beam and Roof

(3D printed wall)

Page 20: APIS COR Boston,MA

ļæ½R. F. . . &Š¢ . fBRICŠ—GSI 1Ā·1ggg .11p,11\ccr111g Ā· cŠ½1ng

ļæ½

Š .!!Jeoso:, ā€¢f 1'.\' 4;,,,,ll.,,. 11.-.

PROJECT:Apis Cor - Lab TestiŠægPROJECT NO.: 30851 PRINTDATE: 11/14/19

Concrete Cylinder Field Test Results - Concrete Samples Fabricated and Tested per ASTM Š”-31, and Š”-39

Mortar Cubes Fabricated and Tested per ASTM Š”-109, Grout Prisms Fabricated and Tested per ASTM Š”-1019

The followiŠæg is Š° report of laboratory test results for concrete cyliŠæders, шortar CLtbes or grout prisins cast iŠæ tl1e field.Š¢Š¾ correlate these results with field testiŠæg, simply match DATE CAST, Š°Šæd SET# vvith field iŠæspectioŠæ reports. SET SPECIMEN DATE DATE AGE SIZE Š¢Š£Š Š• AREA DENSIŠ¢Y ŠœŠŠ„. REQ'D COMPRESSIVE TYPEOF

# NUŠœBER CAST TESTED @ (in.) (sq.iŠæ.) (lbs.cu.ft.) LOAD f'c SŠ¢RENGŠ¢H FRACŠ¢URE

(psi) (ASTM Š”Š—9) TEST (lbs.)

1 lA-AIR 8/7/19 8/8/19 24HR 3.00 Cyl 7.07 128.3 2,990 420 11 lB-AIR 8/7/19 8/8/19 24HR 3.00 Cyl 7.07 128.3 2,700 380 51 lC-AIR 8/7/19 8/8/19 24ŠR 3.00 Cyl 7.07 128.3 2,800 400 51 lA-WATER 8/7/19 8/8/19 24HR 3.00 Š”у! 7.07 128.3 2,980 420 51 lŠ’-WATER 8/7/19 8/8/19 24HR 3.00 Š”у! 7.07 128.3 2,780 390 41 lC-WATER 8/7/19 8/8/19 24HR 3.00 Cyl 7.07 128.3 2,700 380 31 10-AIR 8/7/19 8/9/19 48HR 3.00 Š”у! 7.07 128.3 8,710 1,230 51 lE-AIR 8/7/19 8/9/19 48HR 3.00 Š”у! 7.07 128.3 8,800 1,240 51 lF-AIR 8/7/19 8/9/19 48ŠR 3.00 Cyl 7.07 128.3 8,620 1,220 51 10-WATER 8/7/19 8/9/19 48ŠR 3.00 Š”у\ 7.07 128.3 5,530 780 51 lE-WATER 8/7/19 8/9/19 48ŠR 3.00 Cyl 7.07 128.3 5,930 840 51 lF-WATER 8/7/19 8/9/19 48ŠR 3.00 Cyl 7.07 128.3 5,470 770 51 lG-AIR 8/7/19 8/14/19 7DAY 3.00 Š”у! 7.07 128.3 15,170 2,150 51 lŠ-AIR 8/7/19 8/14/19 7DAY 3.00 Š”у! 7.07 128.3 16,670 2,360 51 ll-AIR 8/7/19 8/14/19 7DAY 3.00 Š”у\ 7.07 128.3 17,450 2,470 51 lG-WATER 8/7/19 8/14/19 7DAY 3.00 Cyl 7.07 128.3 13,870 1,960 51 lŠ-WATER 8/7/19 8/14/19 7DAY 3.00 Š”у! 7.07 128.3 13,790 1,950 51 ll-WATER 8/7/19 8/14/19 7DAY 3.00 Š”у\ 7.07 128.3 13,090 1,850 51 lJ-AIR 8/7/19 9/4/19 28 3.00 Cyl 7.07 128.3 25,380 3,590 51 lK-AIR 8/7/19 9/4/19 28 3.00 Cyl 7.07 128.3 24,780 3,510 51 lL-ATR 8/7/19 9/4/19 28 3.00 Cyl 7.07 128.Š— 26,740 3,780 51 lJ-WATER 8/7/19 9/4/19 28 3.00 Š”у! 7.07 128.3 21,400 3,030 51 lK-WATER 8/7/19 9/4/19 28 3.00 Š”у\ 7.07 128.3 19,750 2,790 51 lL-WATER 8/7/19 9/4/19 28 3.00 Š”у! 7.07 128.3 19,900 2,820 51 lM-AIR 8/7/19 11/5/19 90 3.00 Cyl 7.07 128.3 27,490 3,890 51 lN-AIR 8/7/19 11/5/19 90 3.00 Š”у\ 7.07 128.3 29,410 4,160 51 10-AIR 8/7/19 11/5/19 90 3.00 Š”у! 7.07 128.3 31,170 4,410 5

Remarks: #"';, ;"'Ā°\ .

( \ /ļæ½ f ,11,. // APPROVED:Ā· ļæ½-

--ļæ½

:, Ā·--"-J ltŠ»....rf

20

1

Page 21: APIS COR Boston,MA

ļæ½ R . F. . 1 BRIG GS 1 1ā€¢ 1 g 8:. , 11 g 1 11 ļæ½ Ń ( , 11 &

ļæ½

4 !liYIIIH ā€¢f J'X /Š¾,,,ā€¢Š¾,Š¾,, . .,_.,

PROJECT:Apis Cor - Lab TestiŠæg & Š¢ŃŠ½i11ļæ½

PROJECT NO.: 30851

PRINT DATE: 11/14/19

Concrete Cylinder Field Test Results - Concrete Samples Fabricated and Tested рŠµŠ³ ASTM Š”-31, and Š”-39

Mortar Cubes Fabricated and Tested рŠµŠ³ ASTM Š”-109, Grout Prisms Fabricated and Tested рŠµŠ³ ASTM Š”-1019

Tl1e fo!lovving is Š° report of laboratory test results for concrete cylinders, mortar сŠ½Š¬Šµs or grot1t prisms cast iŠæ the field. Š¢Š¾ correlate these results witl1 field testiŠæg, simply matcl1 ŠžŠŠ¢Š• CAST, and SET# .,,ith field iŠæspectioŠæ reports.

SŠ•Š¢ SPECIMEN DATE DATE AGE SIZE Š¢Š£Š Š• AREA DENSIŠ¢Y ŠœŠŠ„. REQ'D COMPRESSIVE TYPEOF

# NUMBER CAST TESTED @ (in.) (sq.in.) (lbs.cu.ft.) LOAD f'c SŠ¢RENCTH FRACŠ¢URE

TEST (lbs.) (psi) (ASTM Š”Š—9)

1 lM-WATER 8/7/19 11/5/19 90 3.00 Cyl 7.07 128.Š— 25,640 3,630 5

1 lN-WATER 8/7/19 11/5/19 90 3.00 Š”у! 7.07 128.Š— 23,180 3,280 5

1 10-WATER 8/7/19 11/5/19 90 3.00 Š”у! 7.07 128.Š— 26,420 3,740 5

Remarks:

r Šµ_ r fJt 71 APPROVED:

- --- -ļæ½ ....__, , - ----, i

21

Page 22: APIS COR Boston,MA

Compressive Strength Testing according to ASTM C39/C39M-18

2019

ASSOC. PROF.: KAY WILLE PH.D. CANDIDATE: D. HENDRIX CIVIL AND ENVIRONMENTAL ENGINEERING DEPARTMENT, UNIVERISTY OF CONNECTICUT ADVANCED CEMENTITIOUS MATERIALS AND COMPOSITES (ACMC) LABORATORY PHONE: 860-486-2074 EMAIL: [email protected]

For Nikita Cheniuntai, CEO Apis Cor Engineering LLC 4 Park Center Ct, Suite 200-A, Owings Mills, Baltimore, MD 21117

August 15, 2019

2

22

Page 23: APIS COR Boston,MA

Compressive Strength Testing according to ASTM C39/C39M-18 Advanced Cementitious Materials and Composites (ACMC) Laboratory University of Connecticut

Test setup

The objective of this experimental investigation is testing the compressive strength of concrete which was

provided by Apis Corporation.

A servo-hydraulic load frame of 400,000 lb load capacity was used to carry out the test. Figure 1 shows the

test setup located in the Structures Laboratory (FLC 115) at the University of Connecticut. In accordance

with ASTM C39/C39M-18 three cylindrical concrete specimens (designated with no. 4,5 and 7) with a

diameter of 3 inches and a height of 6 inches were tested at a concrete of 28 days. The specimens before

and after failure are shown in Figure 2.

Figure 1 Compressive Strength Test setup

23

Page 24: APIS COR Boston,MA

No 4 before testing No 5 before testing No 6 before testing

No 4 after testing No 5 after testing No 7 after testing Figure 2 Specimens before and after testing

Test results

Table 1 summarizes the compression test results. The average compressive strength and standard deviation

based on the three samples tested is 3.28 Ā± 0.19 ksi or 21.93 Ā± 0.76 MPa.

Table 1 Compressive Strength Test Results

Specimen

no.

Maximum Compressive Load

(kips)

Compressive Strength

(ksi / MPa)

4 24.66 3.49 / 24.1

5 22.19 3.14 / 21.6

7 22.64 3.20 / 22.8

average 3.28 Ā± 0.19 / 21.93 Ā± 0.76

24

Page 25: APIS COR Boston,MA

ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ ļæ½ļæ½ ļæ½ ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ ļæ½ ļæ½ ļæ½ļæ½ ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½

BPvlOSrļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½"ļæ½

$m]uļæ½)lrļæ½+jW^jSSr]jWļæ½9:)ļæ½ļæ½ļæ½(l~Ql^jļæ½FvrSSvļæ½

(ļæ½]WWuļæ½ļæ½ļæ½ļæ½!ļæ½ļæ½ļæ½

$mwļæ½ļæ½ļæ½ļæ½ļæ½ļæ½+|Sļæ½Svvļæ½ļæ½ļæ½ļæ½ļæ½ ļæ½ļæ½ļæ½ļæ½"ļæ½

$wvļæ½#ļæ½ >^b^vNļæ½)fļæ½S^zjvN^ļæ½

+L$:I$G5B?ļæ½B.ļæ½)B?)D+H+ļæ½ļæ½&FB?DMļæ½K?5ļæ½Fļæ½$n]uļæ½ļæ½ļæ½ļæ½ļæ½:ļæ½ļæ½ļæ½GSuv]jXļæ½

*%H+ļæ½D+),4L+*ļæ½

FC+)c<+>ļæ½

=+G3B*ļæ½B/ļæ½%>$;ļæ½MF5Fļæ½

E-FJ:GFļæ½ FnSP^iSjļæ½ļæ½ļæ½ļæ½

DSuoSPvV{fhļæ½ļæ½u{Oi^vvSQļæ½ļæ½

8ļæ½dļæ½eļæ½ļæ½ ļæ½ļæ½ļæ½"ļæ½

G~lļæ½Zlddlļæ½ļæ½ļæ½*ļæ½mļæ½]ļæ½vSRļæ½ļæ½ļæ½ļæ½bļæ½uNimdSuļæ½iNQSļæ½ļæ½ļæ½ļæ½vdļæ½Sļæ½NOl}Sļæ½rSTSļæ½SjPSQļæ½oļæ½aSPvļæ½ļæ½ļæ½Qļæ½QSd_|SrSQļæ½vlļæ½lzrļæ½DlPbfNjQļæ½TNP^g]vļæ½ļæ½Tļæ½ļæ½ļæ½xSuv^jWļæ½ļæ½

FNimd^jWļæ½ļæ½ļæ½Qļæ½GSuv^jWļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½vļæ½ļæ½=Nulļæ½tļæ½ļæ½Jļæ½]vuļæ½$FH<ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½

$WSļæ½Nvļæ½ 0yļæ½luuļæ½GSuvļæ½ļæ½QNļæ½uļæ½ļæ½ 'sSNļæ½ļæ½^jļæ½

ļæ½ļæ½ļæ½ ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½

>Svļæ½FvrSļæ½Xv[pu^ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½

ļæ½ļæ½ļæ½ļæ½:lNQļæ½]jļæ½ļæ½ļæ½"ļæ½!ļæ½ļæ½ļæ½

)ļæ½ļæ½ļæ½SPvSRļæ½FvrSjYvZļæ½qu^ļæ½ļæ½ļæ½ ļæ½ļæ½

(D610Fļæ½+@15A++D7>2ļæ½ļæ½ļæ½G+FG5?0ļæ½ļæ½ļæ½*`|^u^lkļæ½lUļæ½ļæ½ļæ½ļæ½$uulP^NvSu ļæ½4ļæ½ļæ½ļæ½ļæ½

FSNjļæ½Fblrl[lQļæ½*^ļæ½SPvlrļæ½lUļæ½GSuv]ļæ½Wļæ½FSļæ½|^PSuļæ½)ljuvr{Pv]ljļæ½GSP\ļæ½ldlWļæ½ļæ½*^|]u^lkļæ½

ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ ļæ½ļæ½ļæ½ļæ½ ļæ½ļæ½ļæ½ļæ½ ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½\4<Gļæ½ļæ½ļæ½BTC@ļæ½\2ļæ½ļæ½H==D\ 3V>D\Mļæ½\/B8?A6V:ļæ½\JI\ļæ½ļæ½ļæ½" \KAZWR\ļæ½%&ļæ½ļæ½\'"ļæ½ ļæ½ \[\ *5E\ļæ½#'ļæ½\-\'"\ļæ½ļæ½ļæ½ļæ½ļæ½ \

ļæ½ļæ½ļæ½\LUXļæ½;\0B6;\NYļæ½ļæ½OSQAPļæ½ļæ½;ļæ½\1,\ ļæ½ļæ½' ļæ½\

.@ļæ½ļæ½ļæ½ļæ½9\ ļæ½ļæ½ ļæ½ļæ½\ ļæ½'ļæ½)(ļæ½\[\+7F\ļæ½ļæ½ļæ½ļæ½ļæ½\!ļæ½'ļæ½)#$\25

Page 26: APIS COR Boston,MA

ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½

ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ ļæ½ļæ½ļæ½ļæ½ ļæ½ļæ½ ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ ļæ½ļæ½ļæ½ļæ½ļæ½

>I^XHK\ļæ½ ļæ½ ļæ½ļæ½ļæ½ļæ½ļæ½&ļæ½

(ZQ]ļæ½*X\ļæ½-UNQVKKsQUNļæ½88+ļæ½ļæ½ļæ½)XbJXQUļæ½A^sKK^ļæ½

)sQNN]ļæ½ļæ½ ļæ½%"ļæ½ļæ½

(Z^ ļæ½ ļæ½!ļæ½-aK\K^^ļæ½ļæ½kgļæ½ļæ½ļæ½ļæ½!&ļæ½

(^^U'ļæ½ <QRQ^Fļæ½*PKQuU^FQļæ½

.D(8C(ļæ½o4>;ļæ½>0ļæ½*>;*@/B-ļæ½:(A>;@Eļæ½C<4oAļæ½([Q]ļæ½mvsļæ½8rqļæ½BK]^QwOļæ½

7uScļæ½ļæ½" ļæ½ļæ½ļæ½ļæ½ļæ½&ļæ½,(ļæ½niļæ½@-*-4D-,ļæ½

A?-*5:-;ļæ½ BbXļæ½ , ļæ½ZsQU^KJļæ½pXIR]ļæ½{rJtļæ½qyļæ½^PKļæ½^PKļæ½FHXaKļæ½\KLKsKVIKJļæ½ZsYKI^ļæ½FVJļæ½JKSQaK\KJļæ½^Xļæ½v|ļæ½@XIRSFVJļæ½LGIQSQ^cļæ½LX\ļæ½^K]^QVN ļæ½

:-B2>,ļæ½>0ļæ½(;(8ļæ½EA4Aļæ½ AF{ZTQVNļæ½GVJļæ½BK]^QVNļæ½mvwxst^tļæ½:F]XVscļæ½CVQ^]ļæ½(AB: *ļæ½ ļæ½! ļæ½

(NKļæ½G^ļæ½@-AC8BAļæ½ A[KIQWļæ½Kļæ½ļæ½ļæ½ļæ½ BK]_ļæ½JGd]eļæ½

gļæ½ļæ½3XSSXbļæ½ļæ½ ļæ½ļæ½ ļæ½hļæ½ļæ½1~`^KJļæ½ļæ½ ļæ½ļæ½ ļæ½

@K]ZKI^Mļæ½ļæ½ļæ½SScļæ½]ļæ½ļæ½ļæ½H}Q^^KJļæ½ļæ½

)@411Aļæ½-;16;-.@5;1ļæ½ļæ½ļæ½B-AB5=1ļæ½gļæ½,QaQ]QXwļæ½XLļæ½ljļæ½(]]XIQF^K]ļæ½ļæ½5wx ļæ½

ļæ½ ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½Atrwļæ½ARXsXPXJļæ½,QsKI^Xļæ½fļæ½XLļæ½BK]^QVNļæ½AKsaQIK]ļæ½*XV]^suI^QXUļæ½BKIPwXSXNcļæ½,QaQ]QXVļæ½

1sX]]ļæ½gstrļæ½ļæ½QVļæ½ļæ½

%"ļæ½$ ļæ½%% &!ļæ½

(D1 ļæ½

;K^ļæ½ krzļæ½ *X\sKI^KJļæ½A^sKVO^Pļæ½[]Qļæ½ 9XGJļæ½QV ļæ½ A^\Kļæ½ļæ½O^Pļæ½]Qļæ½ļæ½ļæ½#ļæ½ļæ½ ļæ½$# ļæ½ļæ½ ļæ½" ļæ½ļæ½ļæ½ ļæ½ļæ½ļæ½ļæ½ ļæ½#$$&ļæ½ļæ½ ļæ½ļæ½ ļæ½ļæ½

ļæ½"!ļæ½ļæ½ (D1 ļæ½ ļæ½%%ļæ½ļæ½

ļæ½ļæ½ ļæ½ļæ½ļæ½ ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ ļæ½ļæ½ ļæ½ļæ½nDM`&%%XVW[S!n B^aNN\nļæ½ CjQ]ngļæ½+n@YKRSFkLļæ½ndcnļæ½,/6ļæ½neE'ļæ½"#hn ļæ½68$ļæ½n86n$ļæ½4ļæ½1ļæ½nmn<G_nļæ½8n$nļæ½n86$ļæ½101ļæ½n

$nļæ½ļæ½nfil%LnAZHLn;l(%T>O&bUIkLļæ½nA=nļæ½-842n

?S)ļæ½&*Pnļæ½1ļæ½$ļæ½n538ļæ½,:9ļæ½nmn<J_n ļæ½1ļæ½$ļæ½n538ļæ½.:76n26

24

Page 27: APIS COR Boston,MA

ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ ļæ½ļæ½ ļæ½ļæ½ļæ½ ļæ½ļæ½ļæ½ļæ½! ļæ½ ļæ½ ļæ½!ļæ½ļæ½ļæ½ļæ½ ļæ½!ļæ½ļæ½!ļæ½ļæ½!ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½! ļæ½ļæ½ļæ½!ļæ½ļæ½ ļæ½ļæ½+\ļæ½

Neļæ½ļæ½dhļæ½ļæ½Ā°&ļæ½Ā°$ļæ½ļæ½.Ā°

0ļæ½qļæ½Ā°5ļæ½ļæ½Ā°8ļæ½kqļæ½hhļæ½rļæ½kĀ°DD5Ā°%Ā°4ļæ½ļæ½fļæ½qļæ½Ā°Vļæ½Ā©hhļæ½Ā°

4vļæ½qkkļæ½Ā°ļæ½&ļæ½-)#Ā°

1ļæ½ļæ½ļæ½Ā°'%(Ā°9ļæ½hĀ©hļæ½ļæ½Ā°Ā¢ļæ½Ā° ļæ½ļæ½ (.Ā°

0ļæ½ļæ½ļæ½/Ā° Jqxqļæ½bĀ°5nhqļæ½ļæ½ļæ½brĀ°

8_0E^0Ā¦CNKĀ°N;Ā°5NJ5S8X8Ā°Ā£0WNKQ`Ā°Ģ‚ KCĀ¦VĀ°0ļæ½qļæ½Ā°Ā„Ā«Ā©ļæ½EĀØĀ§Ā°Xhļæ½ļæ½qļæ½kĀ°

70Ā°Ā¦ļæ½Ā°R86:A_87Ā°

WP85BI8KĀ°

G8Y@N7Ā°O<Ā°0J0DĀ°Ģ€ WZVĀ°

UW^FXWĀ° Wļæ½heqļæ½hļæ½ļæ½Ā°ļæ½Ā°ļæ½@ļæ½{{ļæ½ļæ½ļæ½Ā°ļæ½Ā° ļæ½>ļæ½ļæ½ļæ½ļæ½hfļæ½Ā°

UG0RĀ”VĀ°

Rhļæ½ļæ½heļæ½jzzļæ½Ā°ļæ½ļæ½dļæ½qļæ½ļæ½hgļæ½Ā°

Whļæ½ļæ½hļæ½dhĀ©Ā°!Ā°,ļæ½Ā°$ļæ½ .Ā°

Xļæ½ļæ½Ā°-ļæ½ĀÆ-ļæ½a+ļæ½Ā°5ļæ½Hļæ½^ļæ½Ā°ļæ½cļæ½ļæ½yhļæ½Ā°ļæ½bfhĀ°Ā§Ā®Ā° ļæ½ohĀ°ļæ½nhĀ°bdļæ½ļæ½hĀ°ļæ½hihĀ©hļæ½ehfĀ°ļæ½ļæ½ļæ½wheļæ½Ā°bļæ½fĀ°fhzqļæ½hļæ½hfĀ°ļæ½ļæ½Ā°ļæ½ļæ½ļæ½Ā°Rļæ½ex{cļæ½fĀ°ibeqzsļæ½Ā°iļæ½ļæ½Ā°ļæ½hļæ½ļæ½qļæ½kļæ½Ā°

Wbļæ½ļæ½zqĀŖkĀ°bļæ½gĀ°Xhļæ½ļæ½tļæ½kĀ°5ļæ½ļæ½eļæ½hļæ½hĀ°Gbļæ½ļæ½ļæ½Ā°^ļæ½qļæ½ļæ½Ā°2VXIĀ°Ā„Ā°!&!(ļæ½Ā°

0khĀ°bļæ½Ā° =ļæ½ļæ½ļæ½ļæ½Ā° Jhļæ½Ā° ļæ½ļæ½ļæ½ļæ½[hļæ½ļæ½Ā°ļæ½fbļæ½ļæ½ļæ½Ā° 3ļæ½hcļæ½Ā°qļæ½ļæ½ļæ½ WĀ°ļæ½ļæ½hļæ½lļæ½~ļæ½ļæ½ļæ½qĀ° Dļæ½bf Ā°uļæ½ļæ½Ā°&+Ā° +.ļæ½-+Ā° ļæ½,(ļæ½Ā° "$"*&ļæ½Ā°&+Ā° ļæ½!.ļæ½ļæ½(Ā° &+.ļæ½Ā° (&.&)ļæ½Ā°

0_=ļæ½Ā° %,ļæ½ļæ½Ā° 0_?ļæ½Ā°

5ļæ½Ā¬heļæ½hgĀ°Vļæ½ļæ½hĀ­mļæ½nļæ½ļæ½ļæ½qĀ°ļæ½$+ļæ½Ā°$++ļæ½Ā°

#.+ļæ½Ā°

4R|==VĀ°9L?CM88T}K=Ā°ļæ½Ā°\8V\CK>Ā°ļæ½Ā°7qļæ½qļæ½qļæ½ļæ½Ā°ļæ½iĀ°Ā¤ Ā°0ļæ½ļæ½ļæ½eqbļæ½hļæ½ļæ½Ā°Cļæ½eļæ½Ā°

Whcļæ½Ā°Wxļæ½ļæ½ļæ½pļæ½gĀ°7qĀ©heļæ½ļæ½ļæ½Ā°ļæ½iĀ°]hļæ½ļæ½qļæ½kĀ°Vhļæ½ļæ½qehļæ½Ā°

ļæ½ļæ½ļæ½\39Iļæ½ļæ½ļæ½ATD<ļæ½\1ECJ99F\ 2V:D\Oļæ½\0B6;=5W7ļæ½\ML\ļæ½ļæ½ļæ½&ļæ½\/>ļæ½ļæ½@9\ļæ½'(ļæ½ļæ½\('ļæ½ļæ½%ļæ½!ļæ½\[\,4G\ļæ½'(ļæ½ļæ½\('ļæ½! !ļæ½\

ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½\NUYļæ½7\0B58\

PZXQSļæ½K?Rļæ½ļæ½7\0.\ļæ½ļæ½(%!\/?ļæ½ļæ½ļæ½ļæ½9\ļæ½!ļæ½ļæ½ļæ½\%#(ļæ½ļæ½)*ļæ½\[\-5H\ ļæ½"ļæ½ļæ½ļæ½\%$( ļæ½*''\

27

Page 28: APIS COR Boston,MA

ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ ļæ½ļæ½ ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½# ļæ½ ļæ½ ļæ½#ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½#"#!ļæ½# ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ ļæ½ļæ½ļæ½ļæ½# ļæ½ļæ½ļæ½ļæ½#ļæ½ļæ½ ļæ½ļæ½ļæ½ļæ½ļæ½

@OvnNQrļæ½ $ļæ½ ļæ½ļæ½)ļæ½

+o_uļæ½ļæ½ļæ½ļæ½ļæ½ļæ½1kZ_kQQļæ½_kZļæ½::/ļæ½ ļæ½.nļæ½Pn_lļæ½FvrQQvļæ½+ovļæ½ļæ½" #ļæ½1}QrQvvļæ½ļæ½ļæ½ļæ½ļæ½ ļæ½#)ļæ½

+xvk*ļæ½ >_b_vMļæ½/[Qk_ykvM_ļæ½

.ļæ½_ZZuļæ½ļæ½ "ļæ½($ļæ½ļæ½

ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ ļæ½ļæ½ļæ½ļæ½

ļæ½ļæ½"ļæ½ļæ½%)ļæ½ļæ½ļæ½vļæ½ļæ½ļæ½ļæ½ļæ½ ļæ½ļæ½ ļæ½ļæ½)ļæ½

B142D3</2ļæ½<I;.2Bļæ½0,G1ļæ½H1FG10ļæ½FA2/7;1<ļæ½ Gļæ½nļæ½"0ļæ½or_kvQPļæ½oļæ½_uiuļæ½iMPQļæ½ļæ½ļæ½ļæ½MkPļæ½PRd_}Qļæ½QPļæ½vnļæ½nyrļæ½CnObeMkPļæ½

:MNnļæ½vnrļæ½ļæ½ļæ½ļæ½ļæ½nv\Qruļæ½ļæ½;1G6@0ļæ½@4ļæ½+=+:ļæ½LF7Fļæ½ FoQO_UOļæ½5rM}_vļæ½ļæ½+Nunļæ½ov_nkļæ½MkPļæ½Kn_Puļæ½_kļæ½6Mļæ½PQkQPļæ½

/nlOrQvQļæ½+FG;ļæ½ļæ½%# ļæ½ļæ½

B3FJ:GFļæ½

FMjodQļæ½

yk_vļæ½

ļæ½,}Qļæ½MZQļæ½

+Nunļæ½ov_nkļæ½MXQrļæ½

ļæ½ļæ½ ļæ½ļæ½iiQļæ½uļæ½ļæ½kļæ½

ļæ½ļæ½ļæ½$ļæ½(ļæ½ļæ½%ļæ½ļæ½ļæ½

ļæ½$ļæ½)ļæ½

-Nunrov_nkļæ½ .yecļæ½MVQļæ½ļæ½ļæ½_iiQļæ½u_nkļæ½ PQku_vļæ½ļæ½ļæ½

Pļæ½ļæ½ļæ½ļæ½Zļæ½ļæ½ļæ½MkPļæ½Nn_e_kZļæ½ļæ½ļæ½ oOSļæ½

ļæ½%ļæ½(ļæ½ ļæ½ļæ½ļæ½ļæ½%ļæ½ļæ½'ļæ½"ļæ½ ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½

ļæ½'ļæ½ļæ½ļæ½ļæ½ ļæ½ļæ½ļæ½ļæ½"ļæ½

.zebļæ½ .ļæ½ebļæ½ +ooMrQkvļæ½ Kndļæ½jQļæ½nSļæ½PQku_vļæ½ļæ½ PQku_vļæ½ļæ½MWQgļæ½ļæ½ ļæ½ļæ½ļæ½iļæ½ļæ½ļæ½ļæ½ļæ½MYQhļæ½ _iiQ`u_nlļæ½ PRku_vļæ½ļæ½

ļæ½Z!ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½uoMORļæ½

_iiR`u_nkļæ½ MkPļæ½Nn_e_kZļæ½ ļæ½}n_Puļæ½ļæ½oOSļæ½ oOSļæ½ oOSļæ½ ļæ½ļæ½

ļæ½ļæ½&ļæ½&ļæ½ ļæ½ļæ½(ļæ½'ļæ½ ļæ½")ļæ½)ļæ½ &ļæ½#ļæ½ļæ½ļæ½'ļæ½ ļæ½ ļæ½ļæ½(ļæ½$ļæ½ ļæ½#ļæ½ļæ½#ļæ½ (ļæ½ļæ½ļæ½

ļæ½ļæ½'ļæ½#ļæ½ ļæ½ļæ½(ļæ½%ļæ½ ļæ½#ļæ½ļæ½ļæ½ļæ½ &ļæ½&ļæ½

8Sļæ½ļæ½n{ļæ½]M~Rļæ½Mmļæ½ļæ½q|Ruw_nmuļæ½nsļæ½ aSļæ½ 8ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½nSļæ½S{tv^Qļæ½ļæ½uQt~_OR ļæ½pfRMuRļæ½OnmvMOvļæ½iRļæ½Mwļæ½ļæ½ļæ½ļæ½ļæ½Onm~Rm_RmORļæ½ļæ½BQuoQOvT{eeļæ½ļæ½uyNj_vvRPļæ½ļæ½

.C955Fļæ½1<57<21E?5ļæ½ļæ½ļæ½G1FG7<5ļæ½ļæ½ļæ½0_}_u_nlļæ½nSļæ½ļæ½ļæ½ļæ½+uunO_MvRuļæ½7kOļæ½ļæ½

ļæ½ļæ½ļæ½ļæ½FRMlļæ½ļæ½ļæ½ļæ½Fbnrn\nPļæ½0_rQOvnļæ½ļæ½nSļæ½GQuv_kZļæ½FQļæ½}_OQuļæ½/nluvļæ½ļæ½Ov_nkļæ½GQO^kndnZļæ½ļæ½0_}_u_nkļæ½

ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½ļæ½d8@Rļæ½ļæ½ļæ½ļæ½2ļæ½OEļæ½d6NMAAFd 7ICGdVļæ½ļæ½d4J<DH9_=ļæ½dTSdļæ½ļæ½")ļæ½d3BKļæ½ļæ½Adļæ½)+ļæ½ļæ½d,)ļæ½ļæ½(ļæ½#ļæ½dcd /:Pd ļæ½)+ļæ½dļæ½d+)dļæ½ļæ½$!%ļæ½d

ļæ½ļæ½ļæ½dU^aļæ½>d4L;=dW]ļæ½ļæ½ļæ½X[ZHYļæ½ļæ½?d51dļæ½ļæ½,(#d

UHb`\dļæ½#ļæ½ļæ½ļæ½d(', -.ļæ½d cd09Qd ļæ½&ļæ½ļæ½ļæ½d(',ļæ½ļæ½-*)d28

Page 29: APIS COR Boston,MA

Flexural Strength of Concrete Using Simple Beam with Center -Point Loading according to ASTM C293/C293M

2019

ASSOC. PROF.: KAY WILLE PH.D. CANDIDATE: D. HENDRIX

UNIVERSITY OF CONNECTICUT ADVANCED CEMENTITIOUS MATERIALS AND COMPOSITES (ACMC) LABORATORY PHONE: 860-486-2074 EMAIL: [email protected]

For Nikita Cheniuntai, CEO Apis Cor Engineering LLC 4 Park Center Ct, Suite 200-A, Owings Mills, Baltimore, MD 21117

November 6, 2019

29

Page 30: APIS COR Boston,MA

Flexural Strength of Concrete Using Simple Beam with Center-Point Loading according to ASTM C293/C293M Advanced Cementitious Materials and Composites (ACMC) Laboratory University of Connecticut

November 6th, 2019

Test setup

The objective of the experimental investigation is testing the flexural strength of six concrete specimens

provided by Apis Cor Engineering LLC according to ASTM C293/C293M-16. Following ASTM

C293/C293M-16ā€“ procedure the specimens were aligned such that the span was 7 inches and the load was

applied in the center of the span. The loading rate was 1 mm/min.

Test conditions - Summary

x Following ASTM C293/C293M-16

x Span: 7 inches

x Loading rate: 1 mm/min

x

Test results

Sample Height (mm)

Width (mm)

Max Load (N)

Displacement at max (mm)

Max Moment

(Nm)

Moment of Inertia

(mm4)

Modulus of Rupture (MPa)

Printed 1 33.5 33.2 357 1.11 15.89 104061 2.56 Printed 2 33.5 33.4 375 0.44 16.67 104562 2.67 Printed 3 33.3 33.4 437 0.31 19.44 102285 3.16 Avg. printed 2.80 Ā± 0.32

Cast 1 32.7 32.9 329 0.60 14.62 96128 2.49 Cast 2 31.7 33.0 575 0.50 25.56 87242 4.64 Cast 3 32.4 32.8 632 0.53 28.08 92694 4.90 Avg. cast 32.4 32.8 632 0.53 28.08 92694 4.01 Ā± 1.32

The height and width were an average of two locations measured on each beam. The maximum load was

recorded by a calibrated load cell during testing. The displacement of the beams was measured by the

crosshead displacement of the test machine. The maximum moment is defined as

š‘€š‘Žš‘„ šæš‘œš‘Žš‘‘ Ɨ š‘†š‘š‘Žš‘›4

(1)

30

Page 31: APIS COR Boston,MA

The moment of inertia is defined as

112

Ɨ š»š‘’š‘–š‘”ā„Žš‘”3 Ɨ š‘Šš‘–š‘‘š‘”ā„Ž (2)

The modulus of rupture is defined as

š‘€š‘œš‘šš‘’š‘›š‘” Ɨš»š‘’š‘–š‘”ā„Žš‘”

2Ɨ

1š‘€š‘œš‘šš‘’š‘›š‘” š‘œš‘“ š¼š‘›š‘’š‘Ÿš‘”š‘–š‘Ž

(3)

The load vs displacement is reported below in Figure 1 for the printed beams and Figure 2 for the cast

beams.

Figure 1 Load vs displacement for printed beams

0

100

200

300

400

500

600

700

0 0.2 0.4 0.6 0.8 1 1.2 1.4

Load

(N)

Displacement (mm)

Printed_1 Printed_2 Printed_3

31

Page 32: APIS COR Boston,MA

Figure 2 Load vs displacement for cast beams

A visual representation of the cracking pattern for the printed beams and the cast beams is shown in Figure 3

a-c) and d-f) respectively. No preferred cracking between the printed layers could be observed. The cracking

pattern of the printed beams was similar to the pattern of the cast beams.

0

100

200

300

400

500

600

700

0 0.2 0.4 0.6 0.8 1 1.2 1.4

Load

(N)

Displacement (mm)

Cast_1 Cast_2 Cast_3

2

Page 33: APIS COR Boston,MA

Figure 3 A visual representation of the cracking pattern for the printed beams a) to c) and the cast beams d) to f).

a)

b)

c)

d)

e)

f)

3