29
OptiX Optical Networking Equipment Rack Layout NTC NTC Huawei Technologies Co., Ltd.

AP Rack Layout Template (V2.0)

Embed Size (px)

Citation preview

Page 1: AP Rack Layout Template (V2.0)

OptiX Optical Networking Equipment

Rack Layout

NTC

NTC

Huawei Technologies Co., Ltd.

B5
Edwin Leong: Insert the name of the project
B6
Edwin Leong: Insert the name of the customer
Page 2: AP Rack Layout Template (V2.0)

OptiX Optical Networking Equipment

Huawei Technologies Co., Ltd.

Page 3: AP Rack Layout Template (V2.0)

Project Name:

Customer:

Station including:

Dimension of Box (Height x Width x Depth)

42mm x 436mm x 293mm

2xSTM-1(o) 16E1 SP2SP2 -- 16 x 2Mb/s Electrical Interface Board

ET1D -- 2 x 10/100M Ethernet Interface Board

N64 -- n x 64kb/s Rate Interface Board

2xSTM-1(o) 8E1 SP2D

2xSTM-1(o) 8E1 SP2D

Designed by

Date

Huawei Technologies Co.Ltd Proprietary Information

Rack Layout Configuration (Metro 500)Rack Layout Configuration (Metro 500)

Page 4: AP Rack Layout Template (V2.0)

NTC

NTC

Dimension of Box (Height x Width x Depth)

SP2 -- 16 x 2Mb/s Electrical Interface Board

ET1D -- 2 x 10/100M Ethernet Interface Board

N64 -- n x 64kb/s Rate Interface Board

Checked by

Version 2.0

Page 5: AP Rack Layout Template (V2.0)

Project Name:

Customer:

Station including:

Dimension of Box (Height x Width x Depth)

42mm x 436mm x 293mm

EFS SCB -- System control board

PD2-D OI2-S - -STM-1 Optical interface board

SCBF02 OI2-D -- 2 x STM-1 Optical interface board

OI4 -- STM-4 Optical interface board

SDE -- 2 x STM-1 Electrical interface board

SLE -- 1 x STM-1 Electrical interface board

EFS PD2-S --16 x E1 Tributary interface board

PD2-D PD2-D -- 32 x E1 Tributary interface board

SCBF02 MR2 -- Add/drop 2 wavelength optical multiplex board

SP1-S/D -- 4/8 x E1 Tributary interface board

SP2 -- 16 x E1 Tributary interface board

SP2 -- 16 x E1 Tributary interface board

EFS PL3-S -- 1 x E3 Tributary interface board

PD2-D PL3-D -- 2 x E3 Tributary interface board

SCBF02 PL3-T -- 3 x E3 Tributary interface board

AIUB -- 2 port ATM Optical interface board

AIUA -- 4 port ATM Optical interface board

ET1 -- 8 port Ethernet board

TDA -- Multi-channel Audio & Data Interface board

EMU -- Environment Monitor Interface unit

Designed by

Date

Huawei Technologies Co.Ltd Proprietary Information

Rack Layout Configuration (Metro 1000)Rack Layout Configuration (Metro 1000)

Page 6: AP Rack Layout Template (V2.0)

NTC

NTC

Dimension of Box (Height x Width x Depth)

OI2-S - -STM-1 Optical interface board

OI2-D -- 2 x STM-1 Optical interface board

OI4 -- STM-4 Optical interface board

SDE -- 2 x STM-1 Electrical interface board

SLE -- 1 x STM-1 Electrical interface board

PD2-S --16 x E1 Tributary interface board

PD2-D -- 32 x E1 Tributary interface board

MR2 -- Add/drop 2 wavelength optical multiplex board

SP1-S/D -- 4/8 x E1 Tributary interface board

SP2 -- 16 x E1 Tributary interface board

SP2 -- 16 x E1 Tributary interface board

PL3-S -- 1 x E3 Tributary interface board

PL3-D -- 2 x E3 Tributary interface board

PL3-T -- 3 x E3 Tributary interface board

AIUB -- 2 port ATM Optical interface board

AIUA -- 4 port ATM Optical interface board

ET1 -- 8 port Ethernet board

TDA -- Multi-channel Audio & Data Interface board

EMU -- Environment Monitor Interface unit

Checked by

Version 2.0

Page 7: AP Rack Layout Template (V2.0)

Project Name:

Customer:

Station including:

Dimension of Box (Height x Width x Depth)

42mm x 436mm x 293mm

OI4 EFS SCB -- System control board

PD2-T OI2-S - -STM-1 Optical interface board

SCBF02 OI2-D -- 2 x STM-1 Optical interface board

OI4 -- STM-4 Optical interface board

SDE -- 2 x STM-1 Electrical interface board

SLE -- 1 x STM-1 Electrical interface board

EFS PD2-S --16 x E1 Tributary interface board

PD2-D PD2-D -- 32 x E1 Tributary interface board

SCBF02 MR2 -- Add/drop 2 wavelength optical multiplex board

SP1-S/D -- 4/8 x E1 Tributary interface board

SP2 -- 16 x E1 Tributary interface board

SP2 -- 16 x E1 Tributary interface board

EFS PL3-S -- 1 x E3 Tributary interface board

PD2-D PL3-D -- 2 x E3 Tributary interface board

SCBF02 PL3-T -- 3 x E3 Tributary interface board

AIUB -- 2 port ATM Optical interface board

AIUA -- 4 port ATM Optical interface board

ET1 -- 8 port Ethernet board

TDA -- Multi-channel Audio & Data Interface board

EMU -- Environment Monitor Interface unit

Designed by

Date

Huawei Technologies Co.Ltd Proprietary Information

Rack Layout Configuration (Metro 1000)Rack Layout Configuration (Metro 1000)

Page 8: AP Rack Layout Template (V2.0)

NTC

NTC

Dimension of Box (Height x Width x Depth)

OI2-S - -STM-1 Optical interface board

OI2-D -- 2 x STM-1 Optical interface board

OI4 -- STM-4 Optical interface board

SDE -- 2 x STM-1 Electrical interface board

SLE -- 1 x STM-1 Electrical interface board

PD2-S --16 x E1 Tributary interface board

PD2-D -- 32 x E1 Tributary interface board

MR2 -- Add/drop 2 wavelength optical multiplex board

SP1-S/D -- 4/8 x E1 Tributary interface board

SP2 -- 16 x E1 Tributary interface board

SP2 -- 16 x E1 Tributary interface board

PL3-S -- 1 x E3 Tributary interface board

PL3-D -- 2 x E3 Tributary interface board

PL3-T -- 3 x E3 Tributary interface board

AIUB -- 2 port ATM Optical interface board

AIUA -- 4 port ATM Optical interface board

ET1 -- 8 port Ethernet board

TDA -- Multi-channel Audio & Data Interface board

EMU -- Environment Monitor Interface unit

Checked by

Version 2.0

Page 9: AP Rack Layout Template (V2.0)

Project Name:

Customer:

Station including:

Dimension of Box (Height x Width x Depth)

42mm x 436mm x 293mm

EFS SCB -- System control board

PD2-T OI2-S - -STM-1 Optical interface board

SCBF02 OI2-D -- 2 x STM-1 Optical interface board

OI4 -- STM-4 Optical interface board

SDE -- 2 x STM-1 Electrical interface board

SLE -- 1 x STM-1 Electrical interface board

EFS PD2-S --16 x E1 Tributary interface board

PD2-D PD2-D -- 32 x E1 Tributary interface board

SCBF02 MR2 -- Add/drop 2 wavelength optical multiplex board

SP1-S/D -- 4/8 x E1 Tributary interface board

SP2 -- 16 x E1 Tributary interface board

SP2 -- 16 x E1 Tributary interface board

SP2 EFS PL3-S -- 1 x E3 Tributary interface board

PD2-T PL3-D -- 2 x E3 Tributary interface board

SCBF02 PL3-T -- 3 x E3 Tributary interface board

AIUB -- 2 port ATM Optical interface board

AIUA -- 4 port ATM Optical interface board

ET1 -- 8 port Ethernet board

TDA -- Multi-channel Audio & Data Interface board

EMU -- Environment Monitor Interface unit

Designed by

Date

Huawei Technologies Co.Ltd Proprietary Information

Rack Layout Configuration (Metro 1000)Rack Layout Configuration (Metro 1000)

Page 10: AP Rack Layout Template (V2.0)

NTC

NTC

Dimension of Box (Height x Width x Depth)

OI2-S - -STM-1 Optical interface board

OI2-D -- 2 x STM-1 Optical interface board

OI4 -- STM-4 Optical interface board

SDE -- 2 x STM-1 Electrical interface board

SLE -- 1 x STM-1 Electrical interface board

PD2-S --16 x E1 Tributary interface board

PD2-D -- 32 x E1 Tributary interface board

MR2 -- Add/drop 2 wavelength optical multiplex board

SP1-S/D -- 4/8 x E1 Tributary interface board

SP2 -- 16 x E1 Tributary interface board

SP2 -- 16 x E1 Tributary interface board

PL3-S -- 1 x E3 Tributary interface board

PL3-D -- 2 x E3 Tributary interface board

PL3-T -- 3 x E3 Tributary interface board

AIUB -- 2 port ATM Optical interface board

AIUA -- 4 port ATM Optical interface board

ET1 -- 8 port Ethernet board

TDA -- Multi-channel Audio & Data Interface board

EMU -- Environment Monitor Interface unit

Checked by

Version 2.0

Page 11: AP Rack Layout Template (V2.0)

Project Name:

Customer:

Station including:

Dimension of Box (Height x Width x Depth)

86mm x 436mm x 293mm

FAN

PIU PIU SCC PIU -- Power Interface Unit

SCC -- System Control & Communication

EOW XCS -- Cross-connection & timing board -STM-1 (o)

XCS1 -- Cross connect & timing board - STM-1 (o)

XCS4 -- Cross-connect & timing board - STM-4 (o)

FEOW -- Engineering Order Wire unit

FAN

PIU PIU SCC FFAN -- System fan interface unit

PL1D -- 16 x E1 interface (75Ω / 120Ω)

EOW MR2 -- Add/drop 2 wavelength optical multiplex board

PM1D -- 16 x E1/T1 interface (100Ω / 120Ω)

PL3 -- 3 x E3 / DS3

TSB3 -- E3 / DS3 switching & bridging unit

FAN

PIU PIU SCC STIA -- Synchronous timing interface board (75Ω)

ET1D -- 2 - port Ethernet electrical interface board

EOW STIB -- Synchronous timing interface board (120Ω)

Designed by

Date

Huawei Technologies Co.Ltd Proprietary Information

Rack Layout Configuration (Metro 1050)Rack Layout Configuration (Metro 1050)

Page 12: AP Rack Layout Template (V2.0)

NTC

NTC

Dimension of Box (Height x Width x Depth)

SCC -- System Control & Communication

XCS -- Cross-connection & timing board -STM-1 (o)

XCS1 -- Cross connect & timing board - STM-1 (o)

XCS4 -- Cross-connect & timing board - STM-4 (o)

FEOW -- Engineering Order Wire unit

FFAN -- System fan interface unit

PL1D -- 16 x E1 interface (75Ω / 120Ω)

MR2 -- Add/drop 2 wavelength optical multiplex board

PM1D -- 16 x E1/T1 interface (100Ω / 120Ω)

TSB3 -- E3 / DS3 switching & bridging unit

STIA -- Synchronous timing interface board (75Ω)

ET1D -- 2 - port Ethernet electrical interface board

STIB -- Synchronous timing interface board (120Ω)

Checked by

Version 2.0

Page 13: AP Rack Layout Template (V2.0)

Project Name:

Customer:

Station Name:

Dimension of Box (Height x Width x Depth)

133mm x 436mm x 293mm

FAN

FPIU FPIU FSCC FPIU -- Power Interface board

FSCC -- System Control & Communication board

FXCS -- Cross-connect & Timing Board

FXCE -- Cross-connect & Timing Board & Expand

FEOW -- Orderwire & Auxiliary Interface board

FFAN -- System fan interface unit

FAN

FPIU FPIU FSCC S16 -- 2.5Gb/a SDH Optical Interface board

SD4 -- 2 x 622Mb/s SDH Optical Interface board

MR2 -- Add/drop 2 wavelength optical multiplex board

SD1 -- 2 x 155Mb/s SDH Optical Interface board

PL1 -- 16 x 2Mb/s PDH Electrical Interface board

ET3D -- 2 x 10/100M Ethernet Service Interface (VC-3)

FAN

FPIU FPIU FSCC GF4D -- 2 x GE Interface board

GF4S -- 1 x GE Interface board

PL3 -- 3 x E3 Interface board with Tributary Protection

TSB1 -- 16 x E1 PDH Interface switching & bridging unit

PL1T -- 16 x E1 Interface unit with Tributary Protection

Designed by

Date

Rack Layout Configuration (Metro 1100)Rack Layout Configuration (Metro 1100)

Page 14: AP Rack Layout Template (V2.0)

NTC

NTC

Dimension of Box (Height x Width x Depth)

FSCC -- System Control & Communication board

FXCS -- Cross-connect & Timing Board

FXCE -- Cross-connect & Timing Board & Expand

FEOW -- Orderwire & Auxiliary Interface board

FFAN -- System fan interface unit

S16 -- 2.5Gb/a SDH Optical Interface board

SD4 -- 2 x 622Mb/s SDH Optical Interface board

MR2 -- Add/drop 2 wavelength optical multiplex board

SD1 -- 2 x 155Mb/s SDH Optical Interface board

PL1 -- 16 x 2Mb/s PDH Electrical Interface board

ET3D -- 2 x 10/100M Ethernet Service Interface (VC-3)

GF4D -- 2 x GE Interface board

GF4S -- 1 x GE Interface board

PL3 -- 3 x E3 Interface board with Tributary Protection

TSB1 -- 16 x E1 PDH Interface switching & bridging unit

PL1T -- 16 x E1 Interface unit with Tributary Protection

Checked by

Version 2.0

Page 15: AP Rack Layout Template (V2.0)

Project Name NTC

Customer NTC

Station including: OptiX 155/622

Power Alarm Dimension of Rack (Height x Width x Depth) 2200mm x 600mm x 300mm

GTC 155/622 Cross connect boardOHP Overhead Process BoardSCC System Control BoardSTG SDH Clock Board

SL1 STM-1 Optical Interface Board SL2 2 x STM-1 Optical Interface BoardSL4 STM-4 Optical Interface Board

SLE STM-1 Electrical Interface BoardSE2 2 x STM-1 Electrical Interface Board

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 PL1 16 x E1 electrical interface boardPD1 32 x E1 electrical interface boardPL3 3 x T3 Electrical Interface board

TDA Multi-channel Audio & Data Interface Board

BA2 Optical Booster Amplifier Board

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

Designed by

Date

Huawei Technologies Co.Ltd Proprietary Information

PL1

SLE

SLE

PL3

PD1

PL1

SLE

PL3

GTC

GTC

SL4

SL4

SL4

SL4

STG

STG

SCC

OHP

PL1

SLE

SLE

PL3

PD1

PL4

SLE

PL1

GTC

GTC

SL4

SL4

SL4

SL4

STG

STG

SCC

OHP

Rack Layout Configuration (OptiX 155/622) Rack Layout Configuration (OptiX 155/622)

Page 16: AP Rack Layout Template (V2.0)

NTC

NTC

Dimension of Rack (Height x Width x Depth)

155/622 Cross connect boardOverhead Process Board

STM-1 Optical Interface Board 2 x STM-1 Optical Interface BoardSTM-4 Optical Interface Board

STM-1 Electrical Interface Board2 x STM-1 Electrical Interface Board16 x E1 electrical interface board32 x E1 electrical interface board3 x T3 Electrical Interface board

Multi-channel Audio & Data Interface Board

Optical Booster Amplifier Board

Checked by

Version 2.0

Page 17: AP Rack Layout Template (V2.0)

Project Name

Customer

OptiX 2500+ OptiX 2500+ Station including: Power Alarm Power Alarm

Dimension of Rack (Height x Width x Depth) 2200mm x 600mm x 600mm

XCSSCC

S16SD4SL4SQ1SD1SL1SQE

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 SDEPD1PQ1PM1PQMPL3

TDAAL1ET1

Designed by

Date

Huawei Technologies Co.Ltd Proprietary Information

PQ1

PQ1

PD1

S16

SD1

SD1

XCS

XCS

SD1

SD1

S16

PD1

PQ1

PQ1

SCC

PM1

PQ1

PQ1

PD1

S16

SD1

SD1

XCS

XCS

SD1

SD1

SD1

SD1

PL3

SCC

PQ1

Rack Layout Configuration (Metro 3000)Rack Layout Configuration (Metro 3000)

Page 18: AP Rack Layout Template (V2.0)

NTC

NTC

Station including:

Dimension of Rack (Height x Width x Depth) 2200mm x 600mm x 600mm

Cross connect and SDH Clock board System control and Overhead process board

STM-16 Optical interface board 2 X STM-4 Optical Interface BoardSTM-4 Optical interface board 4 x STM-1Optical Interface Board2 x STM-1 Optical Interface BoardSTM-1 Optical Interface Board4 x STM-1 Electrical Interface Board2 x STM-1 Electrical Interface Board32 x E1 Electrical Interface Board63 x E1 Electrical Interface Board32 x E1/T1 Electrical Interface Board63 x E1/T1 Electrical Interface Board3 x E3 Electrical Interface Board

Multi-channel Audio & Data Interface BoardATM Optical Interface BoardEthernet Interface Board

Checked by

Version 2.0

Page 19: AP Rack Layout Template (V2.0)

Project Name

Customer

OptiX Metro 3100 OptiX Metro 3100 Station including: Power Alarm Power Alarm

Dimension of Rack (Height x Width x Depth) 2200mm x 600mm x 300mm

XCS -- Cross connect and SDH Clock board SCC -- System control and Overhead process boardSCC -- System control boardPQ1 -- 63x2Mb/s Tributary interface boardPL3 -- 3x34(45)Mb/s Tributary interface board SQE -- 4x155Mb/s electrical interface board SDE -- 2x155Mb/s electrical interface board SD1 -- 2x155Mb/s Optical interface board SQ1 -- 4x155Mb/s Optical interface board SL4 -- 622Mb/s Optical interface board SD4 -- 2x622Mb/s Optical interface board BA2 -- Optical power (boost) amplifier

FAN FAN

Designed By

Date

Huawei Technologies Co.Ltd Proprietary Information

EF4B

ETF4

TSBX

TSBX

PMCU

B P I U

B P I U

EF4B

TSBX

TSBX

PMCU

B P I U

B P I U

PQ1

PQ1

S16

PQ1

SL4

XCS

XCS

SL4

PQ1

S16

PQ1

PM1

SCC

SCC

PQ1

S16

SL4

PD1

SD4

XCS

XCS

SD4

PD1

SL4

PD1

PM1

SCC

SCC

EF4B

TSBX

TSBX

PMCU

B P I U

B P I U

EF4B

TSBX

TSBX

PMCU

B P I U

B P I U

PQ1

S16

SL4

PD1

SD4

XCS

XCS

SD4

PD1

SL4

PD1

PM1

SCC

SCC

PQ1

S16

SL4

PD1

SD4

XCS

XCS

SD4

PD1

SL4

PD1

PM1

SCC

SCC

Rack Layout Configuration (Metro 3100)Rack Layout Configuration (Metro 3100)

Page 20: AP Rack Layout Template (V2.0)

NTC

NTC

Dimension of Rack (Height x Width x Depth)

XCS -- Cross connect and SDH Clock board SCC -- System control and Overhead process board

PQ1 -- 63x2Mb/s Tributary interface boardPL3 -- 3x34(45)Mb/s Tributary interface board SQE -- 4x155Mb/s electrical interface board SDE -- 2x155Mb/s electrical interface board SD1 -- 2x155Mb/s Optical interface board SQ1 -- 4x155Mb/s Optical interface board SL4 -- 622Mb/s Optical interface board SD4 -- 2x622Mb/s Optical interface board BA2 -- Optical power (boost) amplifier

Checked by

Version 2.0

Page 21: AP Rack Layout Template (V2.0)

Project Name NTC

Customer NTC

OptiX 10G OptiX 10G Station including: Power Alarm Power Alarm

Dimension of Rack (Height x Width x Depth) 2200mm x 600mm x 600mm

XCS MXS Cross connect and SDH Clock board A/ETXC 5/10G low order cross connect board

SL64 STM-64 Optical interface boardFAN FAN SF64 STM-64 Colour Optical interface board

SL16 STM-16 Optical interface Board SD16 2 x STM-16 Optical interface Board SLQ4 4 x STM-4 Optical Interface BoardSLO1 8 x STM-1 Optical Interface BoardGE02 2 x Channel Gigabit Ethernet Interface boardEU08 Octuple STM-1 electrical interface boardSP08 Octuple STM-1 signal process boardAEGS Dual Gigabit Ethernet Switch Processing board

Distributing Area Distributing Area APQ1 63×E1 Interface Process boardE75S 63×E1 75W Interface boardE12S 63×E1 120W Interface boardADCU Dispersion compensation boardFE08 8 x Fast Ethernet Interface boardABA Booster Amplifier BoardABPA Booster amplifier & Pre-amplifierTPT Tributary Protection Transmit BoardTPR Tributary Protection Receive Board

1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12

Distributing Area of Optical Fibre

Designed By

Date

Huawei Technologies Co.Ltd Proprietary Information

APQ1

APQ1

APQ1

SL64

TPR

TPT S

L64

SLO1

APQ1

APQ1

APQ1

XCS

XCS

APQ1

APQ1

APQ1

SP08

APQ1TP

RTPT

Rack Layout Configuration OptiX 10GRack Layout Configuration OptiX 10G

Page 22: AP Rack Layout Template (V2.0)

NTC

NTC

Dimension of Rack (Height x Width x Depth)

Cross connect and SDH Clock board 5/10G low order cross connect board

STM-64 Optical interface boardSTM-64 Colour Optical interface boardSTM-16 Optical interface Board 2 x STM-16 Optical interface Board 4 x STM-4 Optical Interface Board8 x STM-1 Optical Interface Board2 x Channel Gigabit Ethernet Interface boardOctuple STM-1 electrical interface boardOctuple STM-1 signal process boardDual Gigabit Ethernet Switch Processing board63×E1 Interface Process board63×E1 75W Interface board63×E1 120W Interface boardDispersion compensation board8 x Fast Ethernet Interface boardBooster Amplifier BoardBooster amplifier & Pre-amplifierTributary Protection Transmit BoardTributary Protection Receive Board

Checked by

Version 2.0

Page 23: AP Rack Layout Template (V2.0)

Project Name

Customer

Metro 2500 Station including: Power Alarm

Dimension of Rack (Height x Width x Depth) 2200mm x 600mm x 300mm

CXLSL16SLQ4

5 6 7 SLD4SL4SLQ1SLD1SL1SEPEU04

1 2 3 4 ### ### ### 8 9 ### ### ### ### ### ### ### ### ### D75SDistributing Area of Optical Fibre PQ1

D12SPIU FAN FAN PIU PQM

PD3PL3D34SSPQ4MU04EFS0EFS4

5 6 7 EGS2ETF8TSB8TSB4FANPIUSAP

1 2 3 4 ### ### ### 8 9 ### ### ### ### ### ### ### ### ###

Distributing Area of Optical Fibre

PIU FAN FAN PIU

Designed By

Date

Huawei Technologies Co.Ltd Proprietary Information

D75S

D75S

D75S

D12S

SL4

SLQ1

SL4

SL4

CX16

CX16

SL16

EFS4

EGS4

SAP

D75S

D34S

TSB4

D75S

D75S

D75S

D75S

D12S

SL4

SLQ1

SL4

SL4

CX16

CX16

SL16

EFS4

EGS4

SAP

D75S

D34S

TSB4

D75S

Rack Layout Configuration OSN 2500Rack Layout Configuration OSN 2500

Page 24: AP Rack Layout Template (V2.0)

NTC

NTC

Station including:

Dimension of Rack (Height x Width x Depth) 2200mm x 600mm x 300mm

STM-1/4/16 Cross&Timing&Line BoardSTM-16 Optical interface board 4 X STM-4 Optical Interface Board2 X STM-4 Optical interface board STM-4 Optical interface board 4 x STM-1Optical Interface Board2 x STM-1 Optical Interface BoardSTM-1 Optical Interface BoardSTM-1 Electrical Interface Board4 x STM-1 Electrical Outlet Board32 x E1/T1 Electrical Outlet Board(75ou)63 x E1 Electrical Interface Board32 x E1/T1 Electrical Outlet Board(120ou)63 x E1/T1 Electrical Interface Board6 x E3/DS3 Electrical Interface Board3 x E3/DS3 Electrical Interface Board6 x E3/DS3 Electrical Outlet Board4 x E4/STM-1Processing Board4 x E4/STM-1Outlet Board10M/100M Ethernet Processing Board4 X 10M/100M Ethernet Processing Board2 X GE Ethernet Processing Board8 X FE Ethernet Outlet Board8 Ports of Electrical Protection Switch Board4 Ports of Electrical Protection Switch BoardFAN BoardPower Supply Unit System Auxiliary Processing Board

Checked by

Version 2.0

Page 25: AP Rack Layout Template (V2.0)

Project Name

Customer

Metro 3500 Station including: Power Alarm

Dimension of Rack (Height x Width x Depth) 2200mm x 600mm x 300mm

XCSSL64SL16SLQ4SLD4SL4SLQ1SLD1SL1SEPEU04D75SPQ1

1 2 3 4 5 6 7 8 9 ### ### ### ### ### ### ### ### 18 D12SDistributing Area of Optical Fibre PQM

PD3PL3D34SSPQ4MU04EFS0EFS4

### ### ### ### ### ### ### ### ### ### ### ### ### ### ### ### ###### ### EGS2FAN FAN FAN ETF8

TSB8TSB4FANPIUBA2

1 2 3 4 5 6 7 8 9 ### ### ### ### ### ### ### ### 18 BPA

Distributing Area of Optical FibreDCUSCCAUX

Designed By

Date

Huawei Technologies Co.Ltd Proprietary Information

PIU

PIU

D75S

AUX

SL64

SL64

XCSA

XCSA

SL64

SL64

Rack Layout Configuration OSN 3500Rack Layout Configuration OSN 3500

Page 26: AP Rack Layout Template (V2.0)

NTC

NTC

Station including:

Dimension of Rack (Height x Width x Depth) 2200mm x 600mm x 300mm

Cross&Timing&Line BoardSTM-64 Optical interface board STM-16 Optical interface board 4 X STM-4 Optical Interface Board2 X STM-4 Optical interface board STM-4 Optical interface board 4 x STM-1Optical Interface Board2 x STM-1 Optical Interface BoardSTM-1 Optical Interface BoardSTM-1 Electrical Interface Board4 x STM-1 Electrical Outlet Board32 x E1/T1 Electrical Outlet Board(75ou)63 x E1 Electrical Interface Board32 x E1/T1 Electrical Outlet Board(120ou)63 x E1/T1 Electrical Interface Board6 x E3/DS3 Electrical Interface Board3 x E3/DS3 Electrical Interface Board6 x E3/DS3 Electrical Outlet Board4 x E4/STM-1Processing Board4 x E4/STM-1Outlet Board10M/100M Ethernet Processing Board4 X 10M/100M Ethernet Processing Board2 X GE Ethernet Processing Board8 X GE Ethernet Outlet Board8 Ports of Electrical Protection Switch Board4 Ports of Electrical Protection Switch BoardFAN BoardPower Supply Unit 2 Ports of Optical Boost Amplify Pre-amplify Dispersion Compensation BoardSystem Communication BoardAuxiliary Interface Board

Checked by

Version 2.0

Page 27: AP Rack Layout Template (V2.0)

Project Name NTC

Customer NTC

Station Name: S11- Makati

Power Alarm

Dimension of Subrack (Height x Width x Depth)

845mm x 530mm x 542mm

FIU -- Fiber Inteface Unit

OBU OPU OBU

SCE -- Syatem Control & Communication Unit

SCC -- System Control & Communication & EOW Unit

SC1 -- Unidirectional supervising channel board

SC2 -- Bidirectional Supervising channel board

1 2 3 4 5 6 7 8 9 10 11 12 13 OLP -- Optical Line Protection board

M32 -- AWG 32 Channel Multiplexing Unit

D32 -- AWG 32 Channel De-multiplexing Unit

OAU -- Optical Amplifier Unit

M32 D32

OBU -- Optical Booster Unit

HBA -- High Booster Amplifier Unit

OPU -- Optical Preamplifier Unit

RPC -- Raman Processing (Driving) Unit

1 2 3 4 5 6 7 8 9 10 11 12 13 LWF -- STM-64 Wavelength conversion board

LRF -- STM-64 Regenerating conversion board

OBU OPU OBU

1 2 3 4 5 6 7 8 9 10 11 12 13

Designed by

Date

Huawei Technologies Co.Ltd Proprietary Information

FIU

SCC

LWF

LWF

LWF

SCE

FIU

SC2

SCC

OLP

Rack Layout Configuration (BWS 320G)Rack Layout Configuration (BWS 320G)

Page 28: AP Rack Layout Template (V2.0)

NTC

NTC

Dimension of Subrack (Height x Width x Depth)

SCE -- Syatem Control & Communication Unit

SCC -- System Control & Communication & EOW Unit

SC1 -- Unidirectional supervising channel board

SC2 -- Bidirectional Supervising channel board

OLP -- Optical Line Protection board

M32 -- AWG 32 Channel Multiplexing Unit

D32 -- AWG 32 Channel De-multiplexing Unit

HBA -- High Booster Amplifier Unit

OPU -- Optical Preamplifier Unit

RPC -- Raman Processing (Driving) Unit

LWF -- STM-64 Wavelength conversion board

LRF -- STM-64 Regenerating conversion board

Checked by

Version 2.0

Page 29: AP Rack Layout Template (V2.0)

Project Name:

Customer:

Station Name:

Power Alarm

Dimension of Subrack (Height x Width x Depth)

666mm x 440mm x 290mm

SMC -- Bidirectional optical supervision channel unit

SCA -- Supervising Channel Access board (SC)

SCC -- System Control & Communication board

VMC -- Variable Management card

CMC -- Optical Coupler Management board

1 2 3 4 5 6 7 8 9 10 11 12 13 14 VOA -- Variable Optical Attenuator board

OLP -- Optical Line Protection board

MS2 -- Bidirectional multi-channel supervisory board

MR2 -- Add/drop 2 wavelength optical multiplex board

D32 -- 32-channel demultiplexer

MB2 -- Bandpass filter expandabel 2-channel

MR2 -- 2 x optical add/drop multiplexer unit

MBM -- Bandpass filter optical add/drop multiplexer board

WBAM01 -- WDM booster amplifier (gain = 20 dB)

LWM -- Multirate Optical wavelength conversion board

1 2 3 4 5 6 7 8 9 10 11 12 13 14 LWX -- Arbitrary rate Optical Wavelength conversion board

LDG -- 2 x Gigabit Ethernet Board

TWF -- STM-64 transmitting wavelength conversion board

RWF -- STM-64 receiving wavelength conversion board

LWE -- Gigabit Ethernet board

Designed by

Date

Huawei Technologies Co.Ltd Proprietary Information

SCC

SCC

Rack Layout Configuration (Metro 6100)Rack Layout Configuration (Metro 6100)

Page 30: AP Rack Layout Template (V2.0)

NTC

NTC

Dimension of Subrack (Height x Width x Depth)

SMC -- Bidirectional optical supervision channel unit

SCA -- Supervising Channel Access board (SC)

SCC -- System Control & Communication board

VMC -- Variable Management card

CMC -- Optical Coupler Management board

VOA -- Variable Optical Attenuator board

OLP -- Optical Line Protection board

MS2 -- Bidirectional multi-channel supervisory board

MR2 -- Add/drop 2 wavelength optical multiplex board

MB2 -- Bandpass filter expandabel 2-channel

MR2 -- 2 x optical add/drop multiplexer unit

MBM -- Bandpass filter optical add/drop multiplexer board

WBAM01 -- WDM booster amplifier (gain = 20 dB)

LWM -- Multirate Optical wavelength conversion board

LWX -- Arbitrary rate Optical Wavelength conversion board

LDG -- 2 x Gigabit Ethernet Board

TWF -- STM-64 transmitting wavelength conversion board

RWF -- STM-64 receiving wavelength conversion board

Checked by

Version 2.0