7/25/2019 AP Armaflex Duct Liner Wrap
1/4
DUCTLINER/WRAP
MOLD RESISTANT, PLENUM-RATED
Closed-cell
to retard
fungal growth
Made with
MICROBAN
antimicrobial
product protection
Factory-applied
or field-applied
product options
Smooth
surface,
less dirt
Meets
NFPA 90A and
NFPA 90B
FM
APPROVED
ALL ARMACELL
FACILITIES IN
NORTH AMERICA
ARE ISO 9001:2000
CERTIFIED.
7/25/2019 AP Armaflex Duct Liner Wrap
2/4
AP Armaflex SA Black Duct Liner/Wrap: The patented elastomeric duct liner and wrap with advanced,superior-grip Pressure Sensitive Adhesive system for non-pinned field applications. The original IAQ Insulation forair handling systems.
AP Armaflex Gray Duct Liner/Wrap: The Armaflex duct liner and wrap for pinned, fabricated factory-appliedduct insulation in accordance with SMACNA requirements*.
Choose AP Armaflex Duct Liner/Wrap for Worry-Free ServiceAP Armaflex is mold resistant and helps reduce or eliminate conditions that lead to biological contamination andbioaerosols in commercial air systems. It is available in several widths, ideal for duct applications.
The surface of the insulation is: Smooth, so that dirt and debris that may enter the air stream tend not to accumulate Durable and erosion-resistant Cleanable and washable, providing a basis for continuing system hygiene.
Engineered to control condensation, AP Armaflex Duct Liner/Wrap has an inherent vapor retarder. Requires no additional mastics or coatings Non-wicking Very low rate of water absorption Continues to prevent water infiltration even after incidental mechanical abuse
Meets StandardsAP Armaflex Duct Liner/Wrap meets the requirements of NFPA 90A, NFPA 90B for Duct Coverings and Linings, andUL 181. Approved for use in return air pleums. Conforms to ASTM C 1534 requirements. This product withstandstemperatures of 250F (121C) when tested according to ASTM C 411.
Factory Mutual System ApprovedAP Armaflex Duct Liner/Wrap is approved through continuing supervision by Factory Mutual Approvals toconsistently provide actual values on these key criteria for mechanical systems performance:Thermal conductivity: 0.27 or less BTU-in/hr sq.ft. FWater vapor transmission: 0.08 or less perm-inchFire rating: Will not contribute significantly to fire.
Description
AP Armaflex is a flexible elastomeric thermal insulation. The expanded closed-cell structure prevents moisture fromwicking and makes it an efficient insulation. It is manufactured without the use of CFCs, HFCs or HCFCs. It isalso formaldehyde free, low VOCs, fiber free, dust free and resists mold and mildew. All AP Armaflex products aremade with Microban antimicrobial product protection for added defense against mold on the insulation.
Our original SA Black Duct Liner/Wrap is supplied in sheets 36 x 48, and in rolls 48 and 60 in width, in nominalthicknesses of 3/8, 1/2, 3/4, and 1 (10mm, 13mm, 19mm, and 25mm). AP Armaflex SA Black Duct Liner/Wrapis supplied in self-adhering sheets and rolls that do not require pinning due to the advanced, aggressive adhesivesystem.
Our Gray Duct Liner/Wrap is supplied in rolls 46-1/4, 47, 48, 56-1/4, 59 and 60 in width, in nominal 1/2(special order) and 1 thicknesses. AP Armaflex Gray Duct Liner/Wrap is intended to be pinned during factoryapplication in accordance with SMACNA requirements.
Uses
AP Armaflex Duct Liner/Wrap is a suitable replacement for traditional materials in air handling systems, VAV units,ducts, and other air system components requiring condensation control and moisture and damage resistance.
Armaflex insulation products must be installed according to Installation of Armaflex Insulators brochure. ProperInstallation is required to assure Armaflex insulation performance.
Application Areas:
Schools, hospitals, hotels, commercial and public buildings.
AP/Armaflex Insulation meets the engery code requirements of International Energy Conservation Code
(IECC) and ASHRAE for R-Value 4 at 1 wall thickness.
7/25/2019 AP Armaflex Duct Liner Wrap
3/4
AP/Armaflex SA Black Duct Liner/Wrap
Patented for Air Systems that Require an Alternative Duct Liner/Wrap
25/50-rated through 1 thickness
Features Benefits
Advanced, aggressive PSA No pinning required, faster installation
Nonwicking Reduced water presence in system andinsulation
Made with Microban antimicrobial Resists mold on the insulationproduct protection EPA registered for use in air duct insulation
Smooth surface that reduces dirt and Inhibits amplification of biological contaminantsdebris accumulation Basis for continuing system hygiene
Elastomeric material Resistant to incidental damage No special tools; no dust mask required during
fabrication and installation
Closed-cell structure Nondusting Longer life Wont contribute to air quality problems
Inherent vapor retarder Requires no mastics Competitive total installed cost
Self-adhering backing Easy to install No solvent vapors (with compression joints)
U.S. Patent 5971034 - Thermal Duct Lining Insulation for lining variable air volume boxes, air handlingunits, and ducts for heat ventilation and air conditioning.
AP/Armaflex Gray Duct Liner/Wrap
For applications that require pinning in accordance with SMACNA
25/50-rated through 1 thickness
Features Benefits
Nonwicking Reduced water presence in system andinsulation
Made with Microban antimicrobial Resists mold on the insulationproduct protection EPA registered for use in air duct insulation
Smooth surface that reduces dirt and Inhibits amplification of biological contaminantsdebris accumulation Basis for continuing system hygiene
Elastomeric material Resistant to incidental damage No special tools; no dust mask required during
fabrication and installation
Closed-cell structure Nondusting Longer life Wont contribute to air quality problems
Inherent vapor retarder Requires no mastics Competitive total installed cost
Self-adhering backing* Easy to install No solvent vapors (with compression joints)
*AP Armaflex Gray Duct Liner is self-adhering. (Available special order without PSA.
When installed using Armaflex 520 Adhesive, no pinning is required, When installed with other
adhesives, pinning is still required.)
7/25/2019 AP Armaflex Duct Liner Wrap
4/4
ARMACELL LLC7600 Oakwood Street ExtensionP. O. Box 1038Mebane, NC 27302
TEL. 800 866-5638 or 919 304-3846FAX 919 304-3847E-MAIL [email protected] www.armacell.com
2006 Armacell LLC Printed in United States of America
021 001 08R 06 NA NA
Armacell provides this information as a technical service. To the extent the
information is derived from sources other than Armacell, Armacell is sub-
stantially, if not wholly, relying upon the other source(s) to provide accurate
information. Information provided as a result of Armacell's own technical
analysis and testing is accurate to the extent of our knowledge and ability,
as of date of printing, using effective standardized methods and procedures.
Each user of these products, or information, should perform their own tests
to determine the safety, fitness and suitability of the products, or combina-
tion of products, for any foreseeable purposes, applications and uses by the
user and by any third party to which the user may convey the products.
Since Armacell cannot control the end use of this product, Armacell doesnot guarantee that the user will obtain the same results as published in this
document. The data and information are provided as a technical service and
are subject to change without notice.
For any updates on this document please refer to our website.
Physical Data
Physical Properties Test Method
Thermal ConductivityBTU-in/hr sq.ft F (W/mK)75F mean temperature (24C) 0.27 (0.039) ASTM C 177 or C 51890F mean temperature (32C) 0.276 (0.040)
Water Vapor PermeabilityPerm-inch [Kg/(s m Pa)] 0.08 [1.16 x 10-13] ASTM E 96 Procedure A
Flame spread and Smoke Developed ASTM E 84index 1 Through 1 (25 mm) 25/50 CAN ULC S-102
Mold growth UL181 Meets requirementsFungi resistance ASTM G21/C1338 Meets requirementsBacterial resistance ASTM G22 Meets requirements
Water Absorption, % by volume 0.2% ASTM C 209
Upper Use Limit 2 180F (82C)
Lower Use Limit 3 -297F (-183C)
Erosion Resistance Does not break away,flake off or show ASTM C 1071evidence ofdelamination atvelocities of 6,000 ft/min
Corrosiveness Noncorrosive ASTM C 665
Odor Emissions No objectionable odors ASTM C 665
Density, typical range 4 3.0 -- 6.0 lbs/ft ASTM D 1622ASTM D 1667
Notes1 AP/Armaflex Duct Liner/Wrap has a flame
spread index of less than 25 and a smokedeveloped index of less than 50 for allthicknesses up to and including 1(25mm) when tested according to ASTME 84 and CAN ULC S-102. Numericalflammability ratings alone may not definethe performance of products under actualfire conditions. They are provided onlyfor use in the selection of products tomeet limits specified.
2 Withstands temperature of 250F(121C) when tested according toASTM C 411. "Test Method for SurfacePerformance of High-TemperatureInsulations". At this temperature,AP/Armaflex Duct Liner/Wrap insulationshows no evidence of flaming, glowing,smoldering, delamination, melting orinsulation collapse. Although this
insulation will withstand hightemperatures, continuous usetemperature should be limited to 180F(82C)
3 At temperatures below -20F (-29C)elastomeric insulation starts to becomeless flexible. However, this characteristicdoes not affect thermal efficiency orwater vapor permeability of Armaflexinsulation.
4 Reference Only
Performance approved through continuingsupervision by Factory Mutual Approval.
Sound Absorption Coefficients at Frequency
Thickness 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz NRC
Nom. 3/4 (19mm) 0.04 0.07 0.16 0.69 0.18 0.25 0.30
Nom. 1 (25 mm) 0.00 0.08 0.32 0.55 0.23 0.21 0.30
ASTM C 423 with ASTM E 795 Type A Mounting
Sound Transmission Class (STC)
Thickness STC Class
Nom. 1/2 (13 mm) 25
Nom. 1 (25 mm) 25
Sizes
Sheet Width/Length SA Black: 36 x 48
Roll Width SA Black: 48 (all thicknesses) and 60 (1 only)Gray: 46-1/4, 47, 48, 56-1/4, 59 and 60
Wall Thickness SA Black: 3/8, 1/2, 3/4 and 1Gray: 1/2 (special order) and 1Test Method ASTM E90
Microban is a registered trademark of Microban Products Company.