32
Anthony Macherone, Ph.D. Sr. Scientist, Agilent Technologies, Inc. Visiting Professor, John Hopkins University SOM

Anthony Macherone, Ph.D. Sr. Scientist, Agilent Technologies, Inc. … · During method development: ... Must pass defined metrics Performance standards provide traceable confidence

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Anthony Macherone, Ph.D. Sr. Scientist, Agilent Technologies, Inc. … · During method development: ... Must pass defined metrics Performance standards provide traceable confidence

Anthony Macherone, Ph.D. Sr. Scientist, Agilent Technologies, Inc. Visiting Professor, John Hopkins University SOM

Page 2: Anthony Macherone, Ph.D. Sr. Scientist, Agilent Technologies, Inc. … · During method development: ... Must pass defined metrics Performance standards provide traceable confidence

Detector-wise: analytical systems are relatively “fixed” There is a great deal of parity across vendors

Sensitivity specs of model compounds in solvent is not “detection”

Detection is more how we utilize the system How we implement the methods in real samples

March 28 - 29, 2015 A. Macherone. Agilent Technologies & JHUSOM 2

Page 3: Anthony Macherone, Ph.D. Sr. Scientist, Agilent Technologies, Inc. … · During method development: ... Must pass defined metrics Performance standards provide traceable confidence

The ability to differentiate real signals from the din of noise Qualitative and quantitative Reliably and with confidence

More than just the detector Must consider holistically

March 28 - 29, 2015 A. Macherone. Agilent Technologies & JHUSOM 3

Page 4: Anthony Macherone, Ph.D. Sr. Scientist, Agilent Technologies, Inc. … · During method development: ... Must pass defined metrics Performance standards provide traceable confidence

Samples and sample preparation

The analytical platform

The methodology The exposome requires measurement many of disparate

chemotypes

Data reduction methodologies Qualitative, quantitative, feature extraction, bioinformatics

March 28 - 29, 2015 A. Macherone. Agilent Technologies & JHUSOM 4

The Internal Exposome Metabolism,

Inflammation, Xenobiotics, Preexisting

disease, Oxidative stress, Gut microbiota

The External Exposome Ionizing radiation, food, air and water, pollution, diet, drugs, stress, infections,

behavior and lifestyle

Sample collection, storage and preparation

Data Acquisition

Bioinformatics

Based on Rappaport & Smith, 2010

Page 5: Anthony Macherone, Ph.D. Sr. Scientist, Agilent Technologies, Inc. … · During method development: ... Must pass defined metrics Performance standards provide traceable confidence

All these can interfere with detection Poorly collected, stored Improperly identified Unknown presence of EDTA, heparin, etc. Very small sample volumes Difficult to split across platforms

March 28 - 29, 2015 A. Macherone. Agilent Technologies & JHUSOM 5

Page 6: Anthony Macherone, Ph.D. Sr. Scientist, Agilent Technologies, Inc. … · During method development: ... Must pass defined metrics Performance standards provide traceable confidence

Bears strongly on what is detected Polar vs. non-polar solvents Hot or cold extractions Bligh-Dyer

For metabolomics - minimize Organic solvent protein crash Spin, filter, dry Reconstitute with appropriate solvent

March 28 - 29, 2015 A. Macherone. Agilent Technologies & JHUSOM 6

Page 7: Anthony Macherone, Ph.D. Sr. Scientist, Agilent Technologies, Inc. … · During method development: ... Must pass defined metrics Performance standards provide traceable confidence

No one technology is “all encompassing”

Must leverage technologies Availability Affordability Accountability Ample coverage of chemical space

March 28 - 29, 2015 A. Macherone. Agilent Technologies & JHUSOM 7

Page 8: Anthony Macherone, Ph.D. Sr. Scientist, Agilent Technologies, Inc. … · During method development: ... Must pass defined metrics Performance standards provide traceable confidence

March 28 - 29, 2015 A. Macherone. Agilent Technologies & JHUSOM 8

Exp

osom

e Sp

ace

ICP-MS NMR GC-MS LC-MS

LC / GC Overlap

NMR

Page 9: Anthony Macherone, Ph.D. Sr. Scientist, Agilent Technologies, Inc. … · During method development: ... Must pass defined metrics Performance standards provide traceable confidence

LC-technologies ESI +/- with HILIC and RP covers a great deal of exposome space Small polar compounds that respond to ESI Not universal ionization Matrix suppression

GC-Technologies EI is universal ionization with largest commercial libraries CI & APCI can be very useful Non-polar, volatiles and semi-volatiles May require derivatization

NMR No real method development required Broad chemotype coverage Highly specific Sensitivity can be an issue

March 28 - 29, 2015 A. Macherone. Agilent Technologies & JHUSOM 9

Page 10: Anthony Macherone, Ph.D. Sr. Scientist, Agilent Technologies, Inc. … · During method development: ... Must pass defined metrics Performance standards provide traceable confidence

Data-driven, knowledge-driven and semi-targeted methods Which and when?

Accuracy and precision

Sensitivity and selectivity

Other challenges: Dynamic range Concentration dependent “in spectrum”

Chromatographic resolution Robustness

March 28 - 29, 2015 A. Macherone. Agilent Technologies & JHUSOM 10

Page 11: Anthony Macherone, Ph.D. Sr. Scientist, Agilent Technologies, Inc. … · During method development: ... Must pass defined metrics Performance standards provide traceable confidence

Data-driven Discovery screening methods, non-hypothesis driven May not detect 70% of the POPs exposome

Knowledge-driven Targeted quantitative methods, hypothesis driven Most sensitive, especially MS/MS

Semi-targeted Combined targeted and screening method Fixed panel of analytes, quantitative Use full spectral information to interrogate data for unknowns Scan, SIM/Scan, MS/MS/scan, triggered MS/MS

March 28 - 29, 2015 A. Macherone. Agilent Technologies & JHUSOM 11

Reproduced from Environmental Health Perspectives (http://ehp.niehs.nih.gov/1308015/)

Page 12: Anthony Macherone, Ph.D. Sr. Scientist, Agilent Technologies, Inc. … · During method development: ... Must pass defined metrics Performance standards provide traceable confidence

Untargeted, qualitative analyses Typically not validated methods

During method development: Known analytes of fixed quantities in matrix are created Characterize the precision of the method

This “performance standard” must be monitored many times during each analytical run Must pass defined metrics Performance standards provide traceable confidence in the precision of the analytical

method

March 28 - 29, 2015 A. Macherone. Agilent Technologies & JHUSOM 12

Page 13: Anthony Macherone, Ph.D. Sr. Scientist, Agilent Technologies, Inc. … · During method development: ... Must pass defined metrics Performance standards provide traceable confidence

Targeted, quantitative & semi-targeted analyses Generally validated methods

During method development: Known analytes of known quantities in matrix must be created Characterize the accuracy and precision of the method

This “quality control” is bracketed around unknowns Monitored multiple times during each analytical run

Must pass defined quantifiable quality metrics Quality controls provide traceable confidence in the accuracy and precision of the

analytical method

March 28 - 29, 2015 A. Macherone. Agilent Technologies & JHUSOM 13

Page 14: Anthony Macherone, Ph.D. Sr. Scientist, Agilent Technologies, Inc. … · During method development: ... Must pass defined metrics Performance standards provide traceable confidence

High mass accuracy and high resolution Offers high specificity and good sensitivity for most drugs, metabolites and dietary

compounds Targeted or semi-targeted analysis will be needed to cover much of the POPs in blood

exposome space

Typically, SQ scan < SQ SIM < MS/MS (quad or trap) < HRMS

March 28 - 29, 2015 A. Macherone. Agilent Technologies & JHUSOM 14

Page 15: Anthony Macherone, Ph.D. Sr. Scientist, Agilent Technologies, Inc. … · During method development: ... Must pass defined metrics Performance standards provide traceable confidence

As much as possible but nothing comes for free Resolving power and resolution are different properties that define instrument and

method related performance, respectively.

Trade offs: Sensitivity reduced as mass resolving power is increased The argument for higher mass resolution may not become persuasive until the molecular weights

being measured become significant

Spectral acquisition rate. “The problem is (the) required time is too long to allow sufficient spectra to be obtained across a

high-resolution (chromatographic) peak for the peak to be properly delineated (sic).”

Especially for GC methods Suspect 20K – 50K fro most applications

March 28 - 29, 2015 A. Macherone. Agilent Technologies & JHUSOM 15

* From: Anthony Macherone, The Future of GC/Q-TOF in Environmental Analysis. In Imma Ferrer and E. Michael Thurman, editors: Comprehensive Analytical Chemistry, Vol. 61, Elsevier. Amsterdam: The Netherlands, 2013.

Page 16: Anthony Macherone, Ph.D. Sr. Scientist, Agilent Technologies, Inc. … · During method development: ... Must pass defined metrics Performance standards provide traceable confidence

March 28 - 29, 2015 A. Macherone. Agilent Technologies & JHUSOM 16

Technique # of ions Specificity PointsMS n n

MS/MS 1 precursor and 2 product ions 4MS/MS 2 precursors each with 1 product ion 5HRMS n 2n

Key1 precursor = 1

1 product ion = 1.5

Page 17: Anthony Macherone, Ph.D. Sr. Scientist, Agilent Technologies, Inc. … · During method development: ... Must pass defined metrics Performance standards provide traceable confidence

Really talking about signal-to-noise (S/N) In matrix, typically MS/MS > HRMS Of course, QTOF may overcome

Many physical ways to improve signal or reduce noise Super-heated drying gas to improve coulombic fission in ESI Multiple capillaries Differentially pumped atmosphere to vacuum chamber Helium quench gas (EI) Off-axis detectors

Relatively fixed across vendors Comparing like systems

March 28 - 29, 2015 A. Macherone. Agilent Technologies & JHUSOM 17

Page 18: Anthony Macherone, Ph.D. Sr. Scientist, Agilent Technologies, Inc. … · During method development: ... Must pass defined metrics Performance standards provide traceable confidence

March 28 - 29, 2015 A. Macherone. Agilent Technologies & JHUSOM 18

Common exposures PM smoke flavinoids minerals lipids amino acids sugars aflotoxins fiber fatty acids APIs excipients volatile solvents POPs etc….

GC-MS Technologies

LC-MS Technologies ICP-MS

NMR

Bioinformatics Requires data-driven methodologies • Generic, broad coverage Contrary to “traditional” analytical chemistry

Page 19: Anthony Macherone, Ph.D. Sr. Scientist, Agilent Technologies, Inc. … · During method development: ... Must pass defined metrics Performance standards provide traceable confidence

Bioinformatic algorithms can compare myriad molecules between disease cases / controls

Pinpoint discriminating exposures

Availability of commercial libraries Human Metabolome Database currently has more than 41,000 entries Metlin database has tandem mass spectra for more than 64,000 small-molecules NIST14 EI mass spectral library: 242,477 unique compounds with chemical structures MS/MS library: 234,284 spectra: 51,216 ion trap spectra of 8,171 compounds and

183,068 collision cell spectra of 7,692 compounds

March 28 - 29, 2015 A. Macherone. Agilent Technologies & JHUSOM 19

Page 20: Anthony Macherone, Ph.D. Sr. Scientist, Agilent Technologies, Inc. … · During method development: ... Must pass defined metrics Performance standards provide traceable confidence

Professor Shane A. Snyder, Ph.D. University of Arizona Environmental Determinants of Susceptibility

LC/MS Triple Quad GC/MS Triple Quad

ICP/MS IC/MS

Polar or moderately polar compounds

Volatile and semi-volatile compounds

Metals and targeted organic complexes

Anions and cations

Targeted quantification

Standard compound

Isolation and

separation of analytes from matrix

Analysis of a small set of predefined target compounds using a particular technique

Identification by RT & MS

Calculation of recovery of surrogates

Sample Data analysis

calculations from internal standards

Quantification of specific

compounds in a sample

LC/MS QTOF GC/MS QTOF

Cell bioassay

Polar or moderately polar compounds

Volatile and semi-volatile compounds

Quantifiable cellular responses from mixtures isolated from biological samples

Non-targeted discovery

Sample QTOF analysis and sample comparisions

Characterization of broader/unknown compounds through untargeted screening techniques

Data alignment and analysis

Validation with MS/MS from standards

Compound profile in a sample

Control Group

Exposure Group

Peak Area

Untargeted organohalogens & complexed metals

LC/GC ICP/MS

Page 21: Anthony Macherone, Ph.D. Sr. Scientist, Agilent Technologies, Inc. … · During method development: ... Must pass defined metrics Performance standards provide traceable confidence

Based on graphic by Shane A. Snyder, Ph.D. University of Arizona Environmental Determinants of Susceptibility

LC/MS Triple Quad

GC/MS Triple Quad

IC/MS Polar or moderately polar compounds

Volatile and semi-volatile compounds

Anions and cations

Semi-targeted analysis: Discovery and quantification

Standard compound

Isolation and

separation of analytes from matrix

Analysis of a small set of predefined target compounds using a particular technique and Characterization of broader/unknown compounds through untargeted screening techniques

Identification by RT & MS

Calculation of recovery of surrogates

Sample Data analysis

calculations from internal standards

Quantification of specific

compounds in a sample

LC/MS QTOF GC/MS QTOF Polar or moderately polar compounds

Volatile and semi-volatile compounds

Sample QTOF analysis and sample comparisions

Data alignment and analysis

Validation with MS/MS from standards

Compound profile in a sample

Control Group

Exposure Group

Peak Area

Untargeted organohalogens & complexed metals

LC/GC ICP/MS

+

Page 22: Anthony Macherone, Ph.D. Sr. Scientist, Agilent Technologies, Inc. … · During method development: ... Must pass defined metrics Performance standards provide traceable confidence

March 28 - 29, 2015 A. Macherone. Agilent Technologies & JHUSOM 22

Reproduced from Environmental Health Perspectives (http://ehp.niehs.nih.gov/1308015/)

Page 23: Anthony Macherone, Ph.D. Sr. Scientist, Agilent Technologies, Inc. … · During method development: ... Must pass defined metrics Performance standards provide traceable confidence

LC-QTOF Metabolites, Drugs, Dietary chemicals

Targeted GC-MS/MS POPs

March 28 - 29, 2015 A. Macherone. Agilent Technologies & JHUSOM 23

Bioinformatics

Many commercially available methods for analysis of 600 to more than 1000 chemicals in a single sample

LC-TOF Methodology described for the analysis of 30K chemical entities from 100 uL sample

Page 24: Anthony Macherone, Ph.D. Sr. Scientist, Agilent Technologies, Inc. … · During method development: ... Must pass defined metrics Performance standards provide traceable confidence

March 28 - 29, 2015 A. Macherone. Agilent Technologies & JHUSOM 24

Targeted GC-MS/MS

400 - 600 compounds

Reproduced from Environmental Health Perspectives (http://ehp.niehs.nih.gov/1308015/)

Semi-targeted GC-QTOF

10s of 1000s

Page 25: Anthony Macherone, Ph.D. Sr. Scientist, Agilent Technologies, Inc. … · During method development: ... Must pass defined metrics Performance standards provide traceable confidence

LC-MS and GC-MS combined: measure > 50K + chemicals

Broad coverage of the exposome space Add ICP-MS for complexed metals, etc.

Use bioinformatics tools to combine and align data

March 28 - 29, 2015 A. Macherone. Agilent Technologies & JHUSOM 25

LC-MS

GC-MS

ICP-MS

Page 26: Anthony Macherone, Ph.D. Sr. Scientist, Agilent Technologies, Inc. … · During method development: ... Must pass defined metrics Performance standards provide traceable confidence

Focusing on the blood exposome can efficiently detect exposures from both exogenous and endogenous sources

Case / controls from prospective cohorts collected over time

High mass accuracy and high resolution MS can offer high specificity and good sensitivity for most drugs, metabolites and dietary compounds

Good method protocols

March 28 - 29, 2015 A. Macherone. Agilent Technologies & JHUSOM 26

Page 27: Anthony Macherone, Ph.D. Sr. Scientist, Agilent Technologies, Inc. … · During method development: ... Must pass defined metrics Performance standards provide traceable confidence

Use system performance standards throughout sequence

Randomize cases and controls

Block a small, fixed number of case / controls between pooled references and QC’s Use equal numbers of cases / controls (e.g., 10 + 10)

Use technical replicates: N ≥ 3 Especially for low or poorly distributed chemicals Run sequentially

March 28 - 29, 2015 A. Macherone. Agilent Technologies & JHUSOM 27

Page 28: Anthony Macherone, Ph.D. Sr. Scientist, Agilent Technologies, Inc. … · During method development: ... Must pass defined metrics Performance standards provide traceable confidence

Use multiple techniques for best coverage of the chemical space

Optimize chromatographic resolution

Use high res accurate mass for discovery May need targeted and semi-targeted

March 28 - 29, 2015 A. Macherone. Agilent Technologies & JHUSOM 28

Page 29: Anthony Macherone, Ph.D. Sr. Scientist, Agilent Technologies, Inc. … · During method development: ... Must pass defined metrics Performance standards provide traceable confidence

Detection is: A composite of Samples and preparation The analytical platform Methodology Bioinformatics

Filtering normal variation from the unknown signals of interest Requires measures of performance and confidence

March 28 - 29, 2015 A. Macherone. Agilent Technologies & JHUSOM 29

Page 30: Anthony Macherone, Ph.D. Sr. Scientist, Agilent Technologies, Inc. … · During method development: ... Must pass defined metrics Performance standards provide traceable confidence

To overcome or mitigate detection challenges: Develop robust methods Use performance standards / QCs for confidence Blend platforms if possible Use best method practices Sophisticated bioinformatics Use more than one

March 28 - 29, 2015 A. Macherone. Agilent Technologies & JHUSOM 30

Page 31: Anthony Macherone, Ph.D. Sr. Scientist, Agilent Technologies, Inc. … · During method development: ... Must pass defined metrics Performance standards provide traceable confidence

Professor Stephen M. Rappaport. University of California, Berkeley

Professor Shane A. Snyder. University of Arizona

March 28 - 29, 2015 A. Macherone. Agilent Technologies & JHUSOM 31

Page 32: Anthony Macherone, Ph.D. Sr. Scientist, Agilent Technologies, Inc. … · During method development: ... Must pass defined metrics Performance standards provide traceable confidence

March 28 - 29, 2015 A. Macherone. Agilent Technologies & JHUSOM 32