Answers for infrastructure. Answers for infrastructure. www.usa.siemens.com/datacenters 4 Planning Tool – fire safety and security solutions for data centers Point type fire detectors FirePrint and ASAtechnology™ offers unsurpassed detection reliability with high immunity to false alarms. Our advanced detection technology is so reliable that it comes with a “No False Alarm” guarantee. 6 Video surveillance The video surveillance system monitors critical zones such as the entrance area etc. to record incidents before and after an event. Our security systems leverage IP based technology and power over Ethernet for easy and seamless interfacing in to the IT infrastructure. 2 Intrusion detection Detection of unauthorized access is critical to the business mission of a data center. Siemens offers a complete range of devices for each kind of risk and application. The complete solution can include for example: protection against flooding, where a special flood detector enables the alarm system to detect water leaks. 4 Alarm indicators If a fire detector that is not easily visible triggers an alarm, an alarm indicator will quickly identify the area in danger. 8 Emergency Voice System The FireFinder XLSV is a full feature life safety system with advanced fire detection, sound and voice evacuation features that are critical in providing clear instructions to building occupants. 10 Releasing control panels The FireFinder XLS and Desigo control panels combine fire detection with automatic suppression (Clean Agent, Single and Double interlock Pre-Action Sprinkler, Deluge). 7 Access control The access control system provides safe and flexible access authorization, time recording, and badge issuing. Many technologies are employed to ensure a solution that is tailored to the customer’s needs. 3 Pull, abort & release stations Manual pull stations, abort stations and manual release stations allow building occupants to provide local input to the life safety system. The local inputs can be used when a manual system alarm, agent release abort and manual agent release are required. 13 Suppression with Sinorix 227 Sinorix 227 is an automatic, waterless suppression solution used to protect any organization’s most vital assets. The clean agent for the Sinorix Fire Suppression System uses HFC227ea. HFC227ea (Model CPY-227) is a clean agent that suppresses fire at low concentrations. Since it is electrically non-conductive, Model CPY-227 is safe for electric and electronic equipment. 11 Suppression with Sinorix 1230 Sinorix 1230 is an automatic, waterless suppression solution used to protect any organization’s most vital assets. This clean agent uses the Novec™ 1230 fire protection fluid. Sinorix 1230 suppresses fire at low concentrations, it is non conductive and safe for electronic equipment. A zero ozone layer depletion factor means Sinorix 1230 is environmentally friendly. 12 Horns, speakers, strobes In a data center, occupants are notified of a fire audibly and visually using horns, speakers or strobes. Occupants can also be notified audibly and visually of a pending discharge. 9 Aspirating smoke detection Provides a highly sensitive system for the earliest possible fire detection in highly ventilated data centers minimizing the risk of fire damage. It is typically applied in closed server racks, false floors, ceilings, cable ducts, air inputs and outputs. 5 Fire control panels The Siemens FireFinder™ XLS and Desigo™ fire alarm control panels convert fire alarms into actions for alarm notification, evacuation and suppression. Thanks to the simple user interface, users can check the system status quickly and take the appropriate actions. Siemens Industry, Inc. Infrastructure & Cities Sector Building Technologies Division 8 Fernwood Road, Florham Park NJ 07932-1906 Tel (973) 593-2600 3M and Novec are trademarks of 3M Company. The information in this document contains general descriptions of some of the typical technical options available. Some of these options do not always have to be present in individual cases. Many additional options not shown here are available from Siemens. The required features should therefore be specified in each individual case at the time of closing the contract. © All rights reserved. Siemens Industry, Inc., 2012 (4/12, Part #153-FSS-100) growing. For our customers, success is defined by how well they manage these challenges. Siemens has the answers. “We are the preferred partner for energy-efficient, safe and secure buildings and infrastructure.” Answers for infrastructure. Our world is undergoing changes that force us to think in new ways: demographic change, urbanization, global warming and resource shortages. Maximum efficiency has top priority – and not only where energy is concerned. In addition, we need to increase comfort for the well-being of users. Also, our need for safety and security is constantly Fire safety and security solutions for data centers Planning Tools 1 7 1 9 10 12 13 11 2 3 5 6 8

Answers for infrastructure. - Siemensw3.usa.siemens.com/buildingtechnologies/us/en/events/Building... · 1 7 9 10 12 13 11 2 5 3 6 8. Answers for infrastructure. Planning Tool

  • Upload
    doantu

  • View
    215

  • Download
    2

Embed Size (px)

Citation preview

Answers for infrastructure.

Answers for infrastructure.www.usa.siemens.com/datacenters

4

Planning Tool – fire safety and security solutions for data centers

Point type fire detectors FirePrint and ASAtechnology™ offers unsurpassed

detection reliability with high immunity to false alarms. Our advanced detection technology is so reliable that it comes with a “No False Alarm” guarantee.

6

Video surveillance The video surveillance system monitors critical

zones such as the entrance area etc. to record incidents before and after an event. Our security systems leverage IP based technology and power over Ethernet for easy and seamless interfacing in to the IT infrastructure.

2 Intrusion detection Detection of unauthorized access is critical to the

business mission of a data center. Siemens offers a complete range of devices for each kind of risk and application. The complete solution can include for example: protection against flooding, where a special flood detector enables the alarm system to detect water leaks.

4

Alarm indicatorsIf a fire detector that is not easily visible triggers an alarm, an alarm indicator will quickly identify the area in danger.

8

Emergency Voice System The FireFinder XLSV is a full feature life safety

system with advanced fire detection, sound and voice evacuation features that are critical in providing clear instructions to building occupants.

10

Releasing control panels The FireFinder XLS and Desigo control panels

combine fire detection with automatic suppression (Clean Agent, Single and Double interlock Pre-Action Sprinkler, Deluge).

7

Access control The access control system provides safe and

flexible access authorization, time recording, and badge issuing. Many technologies are employed to ensure a solution that is tailored to the customer’s needs.

3

Pull, abort & release stations Manual pull stations, abort stations and manual

release stations allow building occupants to provide local input to the life safety system. The local inputs can be used when a manual system alarm, agent release abort and manual agent release are required.

13

Suppression with Sinorix 227 Sinorix 227 is an automatic, waterless suppression

solution used to protect any organization’s most vital assets. The clean agent for the Sinorix Fire Suppression System uses HFC227ea. HFC227ea (Model CPY-227) is a clean agent that suppresses fire at low concentrations. Since it is electrically non-conductive, Model CPY-227 is safe for electric and electronic equipment.

11

Suppression with Sinorix 1230 Sinorix 1230 is an automatic, waterless suppression

solution used to protect any organization’s most vital assets. This clean agent uses the Novec™ 1230 fire protection fluid. Sinorix 1230 suppresses fire at low concentrations, it is non conductive and safe for electronic equipment. A zero ozone layer depletion factor means Sinorix 1230 is environmentally friendly.

12

Horns, speakers, strobes In a data center, occupants are notified of a fire

audibly and visually using horns, speakers or strobes. Occupants can also be notified audibly and visually of a pending discharge.

9

Aspirating smoke detection Provides a highly sensitive system for the earliest

possible fire detection in highly ventilated data centers minimizing the risk of fire damage. It is typically applied in closed server racks, false floors, ceilings, cable ducts, air inputs and outputs.

5

Fire control panels The Siemens FireFinder™ XLS and Desigo™ fire

alarm control panels convert fire alarms into actions for alarm notification, evacuation and suppression. Thanks to the simple user interface, users can check the system status quickly and take the appropriate actions.

Siemens Industry, Inc. Infrastructure & Cities Sector Building Technologies Division 8 Fernwood Road, Florham Park NJ 07932-1906Tel (973) 593-2600

3M and Novec are trademarks of 3M Company.

The information in this document contains general descriptions of some of the typical technical options available. Some of these options do not always have to be present in individual cases. Many additional options not shown here are available from Siemens. The required features should therefore be specified in each individual case at the time of closing the contract.

© All rights reserved. Siemens Industry, Inc., 2012 (4/12, Part #153-FSS-100)

growing. For our customers, success is defined by how well they manage these challenges. Siemens has the answers. “We are the preferred partner for energy-efficient, safe and secure buildings and infrastructure.”

Answers for infrastructure.Our world is undergoing changes that force us to think in new ways: demographic change, urbanization, global warming and resource shortages. Maximum efficiency has top priority – and not only where energy is concerned. In addition, we need to increase comfort for the well-being of users. Also, our need for safety and security is constantly

Fire safety and security solutions for data centersPlanning Tools

1

71

9

10

12

13

11

2

35

6

8

Answers for infrastructure.

Planning Tool – fire safety and security solutions for data centers

Data centers are critical and the heart of many companies’ information infrastructures. No company can allow the failure of its networks and servers because no business can afford downtime or the loss of irreplaceable data and market presence. For some industries, even one or two hours of downtime can be devastating. That is why it is important to provide your data center with the highest level of safety.

Our fire safety and security solutions are tailored exactly to your data center’s requirements. They offer you maximum safety against fire and security risks while helping to ensure uptime and availability of service. Based on the concept of a single, innovative partner, we provide everything including fire detection, security and extinguishing. We also provide expert system design, installation and after-sales service.

Complete solutions for a safe and secure data center – with a single partner

Cost of downtime per hour (Source: Data Center Journal, July 2007)

3.0

2.5

2.0

1.5

1.0

0.5

0.0

($M)Energy

Telecom

Manufacturing

Financial servicesRetail

Pharma

Healthcare

Consumer products

Transportatio

n

Media industry

Travel industry

Integrated and innovative safetyIdentifying and preventing risks Data centers face many challenges – from managing complexity to improving energy efficiency and meeting safety, security and business regulatory requirements. The risk of fire is particularly high due to the presence of a constant ignition source (electricity) and a plentiful supply of combustible materials. Short circuits, due to the extensive cabling, can have serious consequences. The need for comprehensive air cooling results in a higher air exchange making early detection even more challenging. An integrated fire safety concept is therefore crucial to protect critical data and help ensure uptime.

Integrated concept for more safetyAnalyses show that the no. 1 cause offire safety system failure is the interface between detection, alarming, control, and extinguishing. Early and reliable fire detection and the initiation of appropriate extinguishing measures are critical factors in an effective protection concept. Our comprehensive, one-stop fire safety solutions ensure a perfect interaction of fire detection, evacuation, and extinguishing.

We take care of your system throughout its life cycle, including risk analysis, project management, choosing the right systems and offering the best service concept. For an overall secure and energy-efficient data center, our integral concept also includes video surveillance, intrusion detection, and access control as well as building automation and energy management systems. All integrated and controlled by one management station.

Unique safety technologyOur solutions offer you the benefits of advanced technologies like state-of-the-art fire detectors with a “No False Alarm” guarantee and aspirating smoke detection (ASD) for earliest possible warning.

Rely on an experienced partnerWith more than 160 years of experience in fire safety, we understand your specific requirements in terms of prevention, detection, response, and recovery. Our tailored solutions and services comply with the highest safety standards, and incorporate products and systems that meet industry-specific requirements and regulations like UL, FM, ULC, VdS and LPCB.

Highlights

■ Expert support by data center specialists with industry- and application-specific know-how

■ Fully integrated solutions from fire safety, security, building automation to energy management – tailored to your needs

■ Less coordination and reduced costs of ownership thanks to one project manager

■ Ensured safety and uptime due to reliable and integrated fire safety

■ Rapid response time thanks to a global service network – close to you

■ Green solutions thanks to innovative and environmentally friendly technologies

P2Network

X-NET

Desigo CC NCC

Manual pull stations

– Are for immediate manual actuation of a fire alarm or an extinguishing process– Direct alarm actuation by pulling down locking lever– For indoor and outdoor applications– For surface- and recess-mounted requirements

Air duct housings

– Compatible with H-series detectors– Same footprint as exisiting Siemens duct housings– Include optional remote test feature and indicator– New, improved features include easy installation and improved operating

temperature range

Remote indicators

– Are connected to automatic fire detectors that are not easily accessible or visible

Line modules

– Intelligently connect independent, potential-free or make-or-break contacts– Can be independetly configured via a fire control panel for status or alarm messages– Input modules monitor devices responsible for alarm inputs, confirmation signals or technical states etc.– Output modules control other equipment, such as door holders, fire dampers, smoke control systems, plant shutdown etc.

LaserFOCUS VLF-250 LaserFOCUS VLF-500

SEF-MC-W PN: 500-636038

SEF-MC-R PN: 500-636037

SEF-W PN: 500-636042

SEF-R PN: 500-636041

ZR-MC-R PN: 500-636169

LaserCOMPACT LaserPLUS LaserSCANNER

Intrusion*PowerWater Access* VideoAC

Sin

ori

x 1

23

0

Combustible

Heat

Oxy

gen

Releasing with Sinorix™ 1230Siemens recommends Sinorix 1230 based on 3M™ Novec 1230 Fire Protection Fluid. It floods the room within 10 seconds and starts extinguishing before any electronic equipment is severely damaged.

Sin

ori

x 2

27

Combustible

Heat

Oxy

gen

Releasing with Sinorix 227Siemens also has available Sinorix 227. It also floods the room within 10 seconds and starts extinguishing before any electronic equipment is severely damaged by the fire.

Sinorix 1230Sinorix 227

H-series detectors and bases

Thermal detector HFPT-11

Order no.: 500-033380

Photo/Thermal detector HFP-11

Order no.: 500-033290

Remote indicator ceiling mount

ILED-HC

Order no.: 500-048809

Mini single input interface module HTRI-M

Order no.: 500-034000

Single input interface module with relay HTRI-R

Order no.: 500-033300

Dual input interface module

HTRI-D

Order no.: 500-033360

Single input interface module

HTRI-S

Order no.: 500-033370

Control point HCP

Order no.: 500-034860

Conventional zone module

HZM

Order no.: 500-034850

Line isolator HLIM

Order no.: 500-033170

Remote indicator wall mount

ILED-HW

Order no.: 500-048637

RL-HC

RL-HW

DB2-HR

Audible base ADBH-11

Order no.: 500-033210

Single action manual pull

station HMS-S

Order no.: 500-033200

Air duct housing FDBZ492

Order no.: S54319-B22-A1

Dual action manual pull

station HMS-D

Order no.: 500-033400

Air duct housing with relays

FDBZ492-HR

Order no.: S54319-B23-A1

Single action metal manual

pull station HMS-M

Order no.: 500-033450

Optional weather-proof enclosure FDBZ-WP

Order no.: S54319-B26-A1

Example of a stand-alone extinguishing system with an XLS control unit

*Note: These features are planned.

Flooding zone

Cylinder bank